Tender For Additional And Alteration To Building No P-06 (Sump Cum Pump House), P-07 (Power House), P-29 ( Garrage And Servant Qtr) And P-57 (Steel Gate) At Haldia Under Ge (I) (Cg N) Kolkta, haldia-West Bengal

Military Engineer Services-MES has published Tender For Additional And Alteration To Building No P-06 (Sump Cum Pump House), P-07 (Power House), P-29 ( Garrage And Servant Qtr) And P-57 (Steel Gate) At Haldia Under Ge (I) (Cg N) Kolkta. Submission Date for this Tender is 28-03-2024. Pump Supply Tenders in haldia West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

42555710
Corrigendum : Tender For Additional And Alteration To Building No P-06 (Sump Cum Pump House), P-07 (Power House), P-29 ( Garrage And Servant Qtr) And P-57 (Steel Gate) At Haldia Under Ge (I) (Cg N) Kolkta
Open Tender
Indian
West Bengal
haldia
28-03-2024

Tender Details

Additional And Alteration To Building No P-06 (Sump Cum Pump House), P-07 (Power House), P-29 ( Garrage And Servant Qtr) And P-57 (Steel Gate) At Haldia Under Ge (I) (Cg N) Kolkta

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Mar-2024 Revised Date Date 21-03-2024
2 11-Mar-2024 Revised BoQ BOQ 21-03-2024
3 21-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 19 Lakhs /-

BOQ Items

Name of Work: ADDITIONAL AND ALTERATION TO BUILDING NO P-06 (SUMP CUM PUMP HOUSE), P-07 (POWER HOUSE), P-29 ( GARRAGE & SERVANT QTR) AND P-57 (STEEL GATE) AT HALDIA UNDER GE (I) (CG&N) KOLKTA
Sl. No. Item Description
1Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
2Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
3Demolition of cement concrete(unreinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed.
4Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slabs/beams/columns etc. with power/hand driven chisel as directed by the engineer-in-charge upto 25 mm average depth including saw-cutting of all edges making square shoulders of the cavities complete all as specified and as directed. (All loose unsound and cracked concrete shall be removed out side MD land) (Note: thickness will be measured excluding plaster)
5Cleaning loose concrete if any all around reinforcement including from behind the reinforcing bars to give an average 10 mm thick (but not less than 10 mm clear air gap) and cleaning reinforcement of total rust using alkaline rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washed with water and allowing it to dry complete all as specified and as directed. (Note : - Length of reinforcement bars cleaned of rust all around will be measured for payment.) (Note: thickness will be measured excluding plaster)
6Material and labour for providing and applying one coat of Epoxy bonding agent of approved brand. Coverage and specification of manufactures (Mixed density : 1.48 Kg/Ltr, adhesive bond strength to be >2.50MPa) complete all as specified and as directed.
7Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed by Engr-in-charge
8Material and labour for new reinforcement bar for structural connection in RCC beam, column, lintel and slab including powerdrillingholes of appropriate diameter in reinforcement or plain cement concrete to minimum dept of 150 mm and upto 200 mm including power dreilling, fixing the reinforcment in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy catridge etc complete all as specified and as directed by Engineer-in-Charge.
9Supply, mixing and application two component structural grade polymer modified reinstatement morter, where local spalling has taken place or shuttering is not possible . The morter can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 complete all as spd and directedby the Engr-in-charge upto 25 mm average thickness . NOTE:- Cement and sand morter in proportion of 1:2 graded (coarse sand ) with polymer admixed in proportions approved by Engr-in-charge)
10S & F hot rolled medium and high tensile structural steel of grade E 250 quality A conforming to IS 2062: 2011 as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) complete all as specified and as directed.
11M&L Non skid ceramic coloured designer seamless tiles 7 to 8mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm,in floors etc.set and jointed in neat cement slurry and pointed in coloured cementto match the surface over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
12M&L Non skid ceramic coloured designer seamless tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exc 0.38 sqm,in floors etc.set and jointed in neat cement slurry and pointed in coloured cementto match the surface over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
13M & L for 25 mm thik cement concrete 1:2:4, type B0 using 12.5 mm nominal size graded crushed stone aggregate, as in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
14M&L Glazed ceramic coloured designer seamless tiles 300x450x7 to 8 mm thick on vertical surface as in skirting,dado setand jointed with neat cement slurry and pointed incolouredcementto match with the surface over and including 15mm thick screedin CM 1:4 complete all as specified and directed.
15Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed
16Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and directed by Engineer in charge.
17S & F Factory made solid panel PVCdoor shutter 30 mm thick ( style ) consisting of frame work made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour P.V.C‘ C’ channelhaving a PVC sheet strip 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap inserts for top rail; and bottom rail panelling of plain, colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rail with suitable PVC sheets beading and jointed together with solvent cement S&F in frame at site as per specification and drawing in SSR 2020 part-II on page 149 complete all as specified.
18S & F 75 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
19Taking down wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed.
20Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed
21M&L 2nd claas hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
22S&F 30mm thick factory made flush shutters solid coreconstruction, with block board core and plywood face panels, commercial type on both sides but with particle board core with commercial veneering on both face.complete all as specified and as directed.
23S&F 35mm thick glazed skeleton shutters with 2nd class HW open rebated and prepared to recieve glass, gauze, etc (W/o sush bars), edges or framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of member of shutters as specified
24S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
25S & F cast aluminium alloy handle, cast type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
26S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
27S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 250 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
28S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
29M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
30M & L for preparation of old painted wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
31Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
32Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified.
33Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
34Refixing 15 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed.
35Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
36Refixing 20 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed.
37M & L for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
38M & L for anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 no.). hinges type B-21 100 mm long (2 no.) suitable handle (1 no.) complete all as specified
39M & L for cement concrete 1:2:4 type B1 using 40 mm nominal size graded crushed stone aggregate in, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and directed by Engineer-in-charge.
40Supply and fix Aluminium deco grill Cat No DG-104, 10 mm thick ,cut to required size/shape and fixed in position with aluminium beading complete all as specified and directed by Engineer-in-Charge.
41Supply & fixed 5.5 mm thick sheet glass ordinary quality alongwith EPDM rubber all around the glass edges exc 0.50 sqm in each pane and fixed into aluminium frame work complete all as specified and as directed.
42M & L for 20 mm thick granite (Pure black) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
43Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
44Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces in ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
45Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
46Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and fair complete all as specified and as directed.
47M&L for repair to Chajjas/Facias n exc 1.0 sqm area upto 4 storey building including necessary formwork & scafolding, plaster on top, side and soffits of chajjas/facias wherever damaged, RCC 1:2:4 type B1 reinforced duly welded if required and necessary surface finished as per existing complete all as specified.
48M&L for repair to Chajjas/Facias exc 1.0 sqm area upto 4 storey building including necessary formwork & scafolding, plaster on top, side and soffits of chajjas/facias wherever damaged, RCC 1:2:4 type B1 reinforced duly welded if required and necessary surface finished as per existing complete all as specified.
49Supply only liquid water proofing compound.
50M & L for preparation of newly plastered surface ofand applying two coats of oil bound distemper over one coat of alkali resistant primer over 3 mm thick in two coat wall putty (2 +1 mm) to match the existing surfaces complete all as specified and as directed
51M & L for Complete removal of existing treatment of wall and painted surfacesand applying two coats of oil bound distemper over one coat of alkali resistant primer over 3 mm thick in two coat wall putty (2 +1 mm) to match the existing surfaces complete all as specified and as directed
52M & L for preparation of old surface of walls including chajjas, facias etc. by washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of weather proof acrylic exterior paint (100% Acrylic)over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
53M & L for preparing new plaster surfaces walls including chajjas, facias etc. and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of primer including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.
54Preparation of newly plastered surfaces on ceilings and applying two coats of white wash complete all as specified and as directed.
55Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position below or above ground floors, not exceeding 15 cm in depth complete all as specified and as directed.
56S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
57M & L for 50 mm thick cement concrete 1:3:6, type C1 using 20 mm nominal size graded crushed stone aggregatein plinth protection including all necessary formwork complete all as specified and as directed.
58M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 30 cm X 30 cm X 25 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar(1:4) all as specified and as directed.
59S&F in repairs Vitreous china wash hand basin white ,Oval shape of size 550 x 400 mm dia including suitable size of CI brackets, brass chromium plated waste fitting 32mm dia with long screw shank and fly nuts ,flange and vedded in red lead cement complete all as specified and directed by Engr-in-charge.
60S & F 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
61S & F 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
62S&Fin repair Vitreous china squatting pan "Orissa" pattern " size 580x440mm white, with integral foot rest "P" or "S" trap, front or back inlet including connection to trap and to flushing pipe,anti syphonage pipe, etc.incl. making good to floor as existing complete all as specified and directed by Engr-in-Charge.
63S & F 600 mm X 450 mm X 5.5 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
64S & F towel rail 450 mm long of PTMT fixed with and including chromium plated brass screw and wooden/plastics cleats, minimum weight 170 gms complete all as specified and as directed.
65S & F grating doom 125 mm dia with waste hole of PTMT (Minimum weight 40 gms) complete all as specified and as directed.
66S & F grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and as directed.
67S & F 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, bright finish complete all as specified and as directed.
68S & F 15 mm nominal size, pillar taps, cast copper alloy body and body components with capstan heads, spindle, washer plate and nut, with screwed shanks and back nut, with or without lettered hot or cold, nickel-chromium plated finish complete all as specified and as directed.
69S&F Curtain rod 20 mm dia Aluminium fancy type complete with clamps, ring, ball shaped knobs at both end, all golden colour, complete all as directed by Engr-in-charge.
70Taking down existing treatment of any description and any layer from roof including scraping and roughening old by picking, sweeping clean and washing down complete all as specified and as directed.
71M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and providing 10 mm thick cement plaster in CM (1:4) using water proofing compound @ 3 % by weight of cement for filling depression if any to receive water proofing treatment and providing APP modified bituminous membrane water proofing membrane with polyester reinforcement and plain finish of 4 mm thick (not less than 5 kg/sqm ± 5% per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Sqm by the same membrane manufacture of density at 25 C, 0.87-0.89 kg/litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints including for applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed by Engineer-In-charge (Note : WPC shall be measured and paid separately)
72S & F Stop valves cast copper alloy 20 mm dia, screwed down, high pressure, with crutch and butterfly handle screwed both ends for iron pipes or for unions and fixed in repairs all as specified and directed.
73S & F Stop valves cast copper alloy 15 mm dia, screwed down, high pressure, with capstan handle screwed both ends for iron pipes or for unions and fixed all as specified and directed as in repairs.
74S & F Stop valves cast copper alloy 15 mm dia, fancy type,chromium plated with long shank and cup (concealed type) screwed down, high pressure, with capstan handle screwed both ends for iron pipes or for unions and fixedin repairs all as spfd .
75M&L Soap dish, vitreous China white, approximate size 160 x 160 x 90 mm complete.
76S&F for PVC connection 15mm size with PTMT nuts of length for 450mm complete
77S & F brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
78Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of internal dia 150 mm, set in cement mortar complete all as specified and as directed.
79M & L for concrete bed to drain pipes of internal diameter 150 mm, in cement concrete M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed.
80M&L salt glazed stoneware drain pipe 150 mm dia grade "A" laid in trenches and jointed complete all as specified and directed.
81M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
82M & L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified and as directed.
83Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer in charge.
84M & L for brick work with fly ash bricks of class designation 7.5 as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
85Material and labour for brick work with fly ash bricks of class designation 7.5 as per IS 12894: 2002, straight or curved on plan any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and as directed.
86Taking up cast iron water mains (including all fittings), 80 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.
87S & F cast iron, sand cast, socket and spigot, nominal dia 100 mm soil, waste and vent pipe as per IS 1729: 2002 in any length with lead joints, fixed to walls complete all as specified and as directed.
88S & F cast iron bends (any radius) with duck"s foot or heel rest (larger bore measured) without access door for soil, waste and vent pipes of nominal size 50 complete all as specified and as directed.
89M & L for RCC 1:2:4 type B0 using 12.5 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
90M & L for running welding in repair n. exc 2.5cm in length for plate of thickness not exceeding 6 mm complete all as specified and as directed.
91Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed.
92M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
93Dismantling of wrought or mild steel work of any description such as in ladder work, bracing/supporting agle iron, roof top MS sheets, railings etc.
94S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
95M&L for oiling and greasing of rolling shutter of any, size any type including scrubbing down old greasing, oil, dirt of bearing, springs etc. complete all as specified and as directed.
96S & F steel rolling shutters, area not exceeding 8 sqm, lath section made out of 1.00 mm thick sheet, self-coiling type (push-pull type or manual type) without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated complete all as specified and as directed.
97Material and labour 4mm thick non asbestos cement plain building board fixed to timber frame work with screws in ceiling complete all as specified and as directed by Engineer-in-charge.
98Material and labour anodised aluminium snap grid frame work for false ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to thentermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed by Engineer-in-charge. .
99M & L for Hangers 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by mean of ceiling cleats made out of G.I. flat 40x3 mm size long, grid 605mm x 605mm complete all as specified and as directed.
100Taking down carefully the existing aluminium/copper point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, fanregulators, lamp holders, call bell, bell pushesany type etcby unscrewing and taken away from site complete and make good the disturbed surface as existing. Note :(i) cost of unserviceable materials will be charged from the contractor against schedule of credit. (ii) Serviceable light fitting shall be kept in safe custody for reuse at site. (iii) Re-fixing shall be measured and paid seperately.
101Taking down unserviceable submain wiring any size,complete all as specified and directed.
102M&L for point wiring with 1.5 sqmm PVC insulated FRLS sheathed 1100 Volts grade copper multi stranded conductor drawn through and including rigid PVC conduit 20 mm dia concealed in walls ,roofs, etc including 1.5 sqmm PVC insulated copper conductor as earth continuity conductor and other accesories such as metal box, sheet cover, screws,nuts etc connecting it to the common earth dolly all as specified for one light/ceiling fan/Exhaust fan / wall fan each controller by one way switch complete all as specified and directed.
103All as per item no 103 but one 3 pin 5 Amps socket outlet on same board controlled by one switch complete all as specified and directed.
104All as per item no 103 but one 3 pin 5 Amps socket outlet independent controlled by one switch complete all as specified and directed.
105All as per item no 103 here in before but with 2.5 sqmm cable copper for 15/16 Amps socket outlet on independent board,including 2.5 sqmm copper conductor PVC insulated sheathed continuous earth wire and connecting to common earth dolly. complete all as specified and directed.
106M & L Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC Conduit conceiled type2x4.0 sq.mm + 1x4.0 sq. mm for earth wire all as specified and directed
107Supply and fix LED batten 20 Watt extruded aluminium housing,high power diffuser, slim and integrated design, lumen not less than 2100 lumen polycarbonate, energy efficient fixed to wall/ ceilling and connecting upto ceilling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed.
108Supply and fix LED batten 10 Watt extruded aluminium housing,high power diffuser, slim and integrated design, lumen not less than 1000 lumen polycarbonate, energy efficient fixed to wall/ ceilling and connecting upto ceilling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed.
109Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
110M & L Switch Modular type single pole, one way 6 Amp complete all as specified and directed.
111M & L Modular Switch socket combination outlet 3 pin 6 amp" flush type combined 3 module complete all as specified and directed.
112M & L modular Switch socket combination multipurpose 3 pin, 16 amp and one pin, 6 amp controlled by one switch 3 module complete all as specified and directed.
113S & F Modular Fan step regulator, 120W - 2 module complete all as specified and directed.
114S & F Modular White cover plate with frame 1/2 M incl taking down old one complete all as specified and directed.
115S & F Modular White cover plate with frame 3 M incl taking down old one complete all as specified and directed.
116S & F Modular White cover plate with frame 4 M incl taking down old one complete all as specified and directed.
117S & F Modular White cover plate with frame 6 M incl taking down old one complete all as specified and directed.
118S & F Metal flush box 1/2 module incl taking down old one complete all as specified and directed.
119S & F Metal flush box 3 module incl taking down old one complete all as specified and directed.
120S & F Metal flush box 4 module incl taking down old one complete all as specified and directed.
121S & F Metal flush box 6 module incl taking down old one complete all as specified and directed.
122S & F ceiling rose 3 terminal PVC/polycarbonate isolated body type complete all as specified and directed.
123Supply and fixing SP 6-32 amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
124Supply and fixing SPN 32 amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
125Supply and fix 4 way SPN Double door DB with 200 amps rated bus bar complete all as specified and directed.
126Supply and fix 8 way SPN Double door DB with 200 amps rated bus bar complete all as specified and directed.
127Supply and Fix blank plate of 1 module for switch and MCBs complete all as specified and directed.
128Taking down ceiling fan/ exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store Complete all as specified and directed.
129Servicing of ceiling fan/exhaust fan incl open all parts, lubrication, cleaning and other necessary job to make smooth run of the item Complete all as specified and directed.
130M & L for Painting of ceiling/ wall fans and Exhaust fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
131Re-Hangingceiling fan (M.D. supply), serviceable light fitting and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.
132Re-Fixing only exhaust fan (M.D. supply) and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed.
133Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm long including 40 mm dia GI pipe of length 1.2 Mtr with clamping, nuts, bolts, base plate , PCC foundation complete all as specified and directed by Engr-In-Charge.
134Supply & fix aluminium strip 25 mm x 3 mm complete with saddles and fixing screws for conductor and ground conductor above ground complete all as specified and directed.
135S & F Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
136M & L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
137Supply and fixing LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and directed.
138Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 4 core complete all as specified and directed.
Disclaimer :