Power Development Department has published Creation Of 100 Kva Sub Station Along With Ht/Lt Line At Plailunder Water Supply Scheme Jjm(Phe)In Respect Of Electric Sub-Division Billawar Of Electric Division Kathua On Turnkey Basis.. Submission Date for this Tender is 30-03-2024. Overhead Line Tenders in billawar Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 19-Mar-2024 | Extension Notice01 | Date | 30-03-2024 |
Sl. No. | Item Description |
1 | Creationof100 KVASub Station atPlail under JJM Scheme in respect JPDCL ElectricSub Division Billawar of Electeic Division Kathua on Turnkey Basis by way of supply Erection/ Installation,Testing Commissioningof following Material: |
2 | 11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ) up to200 KVA, copper WoundandwithLV Cable Box having detachable Aluminium Gland plate. |
3 | Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type |
4 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
5 | 11 kV Horn GapFuse Set 3 Phase 200A |
6 | 120 mm² (1Ckt) Single PhaseCable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type |
7 | 9 Mtr. Longpole (ST-410 SP 33) |
8 | 11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
9 | GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap |
10 | Galvinized Nuts and Bolts. |
11 | Earthing of substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
12 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
13 | LT Distribution box for 100 KVADTR with MCCB for incommer & SFU"sfor outgoing ckt |
14 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
15 | Wedege connectors /PG clamps |
16 | Danger plate with clamps |
17 | GI Barbed wire for ani Clambing |
18 | 3 Ph 4 Wire Trivector meterwith CT |
19 | Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole |
20 | Painting of polesRed oxide |
21 | Painting of polesAluminum Paint |
22 | Erection ofHTline on 9 Mtrs. STpoles with ACSR Weasel Conductor at Plail under JJM Scheme in respect JPDCL ElectricSub Division Billawar of Electric Division Kathua on Turnkey Basis byway of supply Erection/Installation,Testing Commissioning etc of following Material: |
23 | 9 Mtr. Longpole (ST-410 SP 33) |
24 | GI V cross-arm/Horizontal with top Bracket including clamp |
25 | GI Channel x-arm includingclaps and braces |
26 | 30 mm² ACSR Weasel Conductor |
27 | PG Clamps forACSR weasel conductor |
28 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
29 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
30 | Galvanized Nuts and Bolts |
31 | Danger Plates with Clamp |
32 | Anti Climbing Devices with clamps |
33 | Red oxcide Paint |
34 | Aluminium Paints |
35 | Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole |
36 | Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip |
37 | Aluminium Jointing Sleeves |
38 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
39 | Erection of 11 KV Tapping pointat Plail under JJM Scheme in respect JPDCL ElectricSub Division Billawar of Electric Division Kathua on Turnkey Basis byway of supply Erection/Installation, Testing Commissioning et of following Material: |
40 | 9 Mtr. Long Pole(ST-410 SP-33) |
41 | GI V cross-arm/Horizontal with top Bracket including clamp |
42 | GI Channel/ angle iron including Clamps |
43 | 11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type |
44 | 30 mm² ACSR Weasel Conductor |
45 | PG Clamps for 30mm2 ACSR conductor |
46 | 11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm |
47 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm |
48 | Galvanized Nuts and Bolts |
49 | Danger Plates with Clamps |
50 | Anti-Climbing Device with Clamps |
51 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
52 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
53 | Cement bottoming 1:2:4 Mix as per REC Standars |
54 | Aluminium Paint |
55 | Red oxide paint |
56 | Laying ofLT line on 8 Mtrs. STpoles with ACSR Weasel Conductor 3Phase 4 wire atPlailunder JJM Scheme in respect JPDCL ElectricSub Billawar Kathua of Electric Division Kathua Turnkey Basis byway of supply Erection/Installation, Testing Commissioning et of following Material: |
57 | 8 Mtr. Longpole (ST-410 SP 15) |
58 | GI U-Clamp for Shackle insulators |
59 | Shackle insulator 16 KN |
60 | 30 mm² ACSR Conductor |
61 | Galvanized Nuts and Bolts |
62 | Danger plates |
63 | Anit Climbing Device with Clamps |
64 | Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip |
65 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
66 | Cement bottoming 1:2:4 Mix as per REC Standars |
67 | Aluminium Paint |
68 | Red oxide paint |