Tender For Rohtak No.2 Wqmsp(2023-2024) (01.04.2023) - (31.03.2024) `Supply Installation And Commissioning Of Water Testing Equipments Phe Lab Rohtak Under Jurisdiction Of Phe Divn.No-2 Rohtak Distt. Rohtak`, rohtak-Haryana

Public Health Engineering Department-PHED has published Tender For Rohtak No.2 Wqmsp(2023-2024) (01.04.2023) - (31.03.2024) `Supply Installation And Commissioning Of Water Testing Equipments Phe Lab Rohtak Under Jurisdiction Of Phe Divn.No-2 Rohtak Distt. Rohtak`. Submission Date for this Tender is 13-03-2024. Water Testing Accessories Tenders in rohtak Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42539828
Tender For Rohtak No.2 Wqmsp(2023-2024) (01.04.2023) - (31.03.2024) `Supply Installation And Commissioning Of Water Testing Equipments Phe Lab Rohtak Under Jurisdiction Of Phe Divn.No-2 Rohtak Distt. Rohtak`
Open Tender
Indian
Haryana
rohtak
13-03-2024

Tender Details

Tender For Rohtak No.2 Wqmsp ( 2023-2024 ) ( 01.04.2023 ) - ( 31.03.2024 ) `Supply Installation And Commissioning Of Water Testing Equipments Phe Lab Rohtak Under Jurisdiction Of Phe Divn.No-2 Rohtak Distt. Rohtak` 1. Autoclave Vertical • Size-78 Ltr / 98 Ltr 2. Bacteriologic Al Incubatorinner Size: 18` X 18` X 24`, 3.Colour Comparator For Colour 4. Digital Burette 5. Multi-Meterwith Ph 6. Pipette Controller 7. Turbidity Meter ( Benchtop ) / ( Portable )

Key Value

Document Fees
INR 1000 /-
EMD
INR 17720.0 /-
Tender Value
INR 8.86 Lakhs /-

BOQ Items

Name of Work: Rohtak No.2 WQMSP(2023-2024) (01.04.2023) - (31.03.2024) `Supply installation and commissioning of water testing equipments PHE Lab Rohtak under Jurisdiction of PHE Divn.No-2 Rohtak Distt. Rohtak`
Sl. No. Item Description
1Autoclave Vertical • Size-78 ltr/ 98 ltr • It should have double wall construction with boiler made of Stainless Steel 16-gauge sheet. Outer shell is also made of Stainless-Steel Sheet/ Mild Steel. Boiler and outer shell are provided with air insulation. Lid is made of Stainless-Steel Sheet and tightened all-round by radial locking. Joint less gaskets are made of Neoprene rubber. These sterilizers are hydraulically tested up to 40 PSI. • Should have fully automatic PID Controller • Automatic timer electronic 999 mtsSterilizers are fitted with water level arrangementto indicate water position inside the boiler. Pressure gauge, Air/Steam release cock two safety valve are also provided. The autoclave is fittedwith indfoss pizzostat and can be set between 10 to 20 PSI. • Immersion type heating element heats the water and steam to desired temp. and pressure are attained. We have provided all autoclaves to cutoff automatically when the autoclave is dry. Supplied complete with S.S. basket, cord and plug to work on 220 Volts 50 cycles A.C. supply • Traceability calibration certificate of controller should be provided • Instrument should be calibrated from NABL calibration laboratory. • Includes AMC for 5 years Make Popular, NST, Ambassador
2Bacteriologic al incubator Inner Size: 18` x 18` x 24`, Rating Watts 750, No. ofShelves 3, capacity 120Ltrs Construction: Doublewalled construction outer body made of Mild Steelpowder coated, and Inner Body made of Stainless-SteelInsulation: Glass wool insulation between two walls.Temp range: room temperature to 60°C. Accuracy: plus /- 0.5 °C. Temp controlled by: Controlled by PIDMicro process controller with dual display. Selves:With G.I. wire Mesh selves Door: 2 door inner acrylicdoor to view sample and outer metal door. with aircirculation motor with blower for uniformtemperature throughout chamber. Heater: specialNichrome heater designed for long life and saving of power consumption
3Colour Comparator for colour,Applicable Standard ASTM D1209 ISO 6271,Colour Type Transparent,Portability: Portable Range-Visual Colour Grading of PlatinumCobalt/Hazen/APHA Colour (Range 0 - 250 mg),Disc-NSB Hazen scale disc Range: -70 - 250 mg Pt/l,CAA Hazen scale disc Range: -0-30 mg Pt/l,CAB Hazen scale disc Range: -30-70 mg Pt/l,(The bidder should provide Colour Glass disc),Nessleriser,1 X Pair Nessleriser Daylight 2000 plus ,1 X Pair Stand for Nessleriser Unit,1 X Pair 2150 Nessleriser body,1 X Pair 2250 Nessleriser body,1 X Pair of Nessler cylinder AF306P,1 X Pair of Nessler cylinders 250mm,DB420,Certification,The company should have ISO Certification for,manufacture Water testing Instruments (NST,Ambassador,OpticsTechnology)
4Digital Burette Technical Specifications for Bottle top burette: 1. The bottle top burette should have motorcontrolled piston movement.,2. There will be different speed modes a. Fast,b. Medium,c. Slow to control dispensing speeds and to facilitate,accurate titrations.3. Bottle top burette should be able to dispense adroplet as small as 0.01 ml to ensure highly accurate end point. 4. It will have re-circulation mode that allows quick purging without loss of reagent. to provide ease ofuse and save time, the burette should provide onetouch filling operation and refilling should be donewithout change in on-screen reading. 5. Capacity: 50 ml 6. Increment: 0.01 ml 7. Systematic Error: Precise titration with the error limits of Class A: = 0.1% at nominal volume 8. Random Error: =0.02% at nominal volume (Microlit,Sartorius,Thermo FisherScientific,Brand, Borosil)
5Multi-meterwith pH,Conductivity and DO Automatic Buffer Recognition: Yes,Backlight: Yes,Barometric Pressure Measurement: Automatic,compensation of DO when using an LDO or LBOD,probe,Calibration: Demal (1D/ 0.1D/ 0.01D).,Molar (0.1M/ 0.01M/0.001M),NaCl (0.05%: 25µS/cm: 1000µS/cm: 18mS/cm)Standard sea water,User defined Calibration Intervals/Alerts/Reminder:Off, selectable from 2 hours to 7 days,Communication: Integrated USB type A (for USB 2.0 flash memory device, printer, keyboard) and Integrated USB type B (for PC) Compliance Certifications: CE. WEEE (Certifications are applicable only for European Union and USA)Conductivity measurement: Yes Conductivity measurement: Temperature correction: None: Linear: NaCl Non-Linear Natural Water. Conductivity Measurement Range: 0.01 µS/cm -200.0 mS/cm Conductivity resolution: 0.01 µS/cm - 0.1 mS/cm upon selected measuring range Contents: Meter Only,Custom Calibration Standards: Yes ,Data Export: Download via USB connection to PC or,flash memory device. Automatically transfer entire ,data log or as readings are taken., Data Memory: 500 records/FIFOData Storage: Automatic, GLP ISO compliant reading data stored with calibration details. Dimensions: 859 x 175 x 235 mm,Display: Detailed mode/Large mode,Display Type: 440 x 160-pixel LCD with backlight,illumination,DO Measurement Range: 0.1 - 20.0 mg/L (ppm) 1 -200% saturation,DO Resolution: 0.1,DO sensor calibration: • 100% (water-saturated air,(100%) calibration,• 100% with 0 (water-saturated air (100%) calibration with 0 point,• mg/L (calibration with a specified dissolved oxygen,concentration (mg/L) solution),• mg/L with 0 (calibration with a specified dissolved,oxygen concentration (mg/L) solution with 0 point) • Factory (calibration with the default LDO calibration) ,Electrode stand: Optional,GLP Features: Date: Time: Sample ID: Operator ID,Instrument: Bench,IP Rating: IP54 (Resistant to spray of water: Dustproof),ISE Direct Measurement Range: Yes,ISE Electrode Calibration: 2 - 5 points,Kit (Yes/ No): No,Lock Function: Continuous / Auto-stabilization (`pressto read`) / At Interval,Measurement method: Probe specific programmed method settings,mV Measurement at Stable Reading: Yes,mV Measurement Range: -1500 - 1500 mV,mV Resolution: 0.1 mV,Needed Cable Length: 2m or more,Operating Error Messages: Clear text error messages,displayed,Operating Humidity: 90 % relative humidity (noncondensing),Operating Interface: Soft Touch Keypad,Operating Temperature: 0 -plus 60 °C (32 - 140 °F),ORP Electrode Calibration: Predefined ORP standards (including Zobell`s solution),Parameter: pH/ Oxydo Reduction Potential (ORP)Conductivity/Total Dissolved Solid,,(TDS)/Salinity/Resistivity,Dissolved Oxygen (DO) Biochemical Oxygen Demand (BOD),Ion Selective Electrode (ISE): Ammonia, Ammonium,Chloride, Fluoride, Nitrate, Sodium,PC Data Transfer Software: HQd Series Meter DataTransfer Utility,pH Buffer Sets: Color-coded: 4.01, 7.00, 10.01 pH:,IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 pH DIN: 1.09, 4.65, 9.23 pH User-defined custom buffer sets,pH Electrode calibration: 1 - 3 Calibration points,Calibration summary data logged and displayed,pH Measurement Range: 0 - 14 pH,pH Resolution: Selectable:0.001/0.01/0.1 pH,Printer: Yes, Optional,Probes included: DO, pH and conductivity/TDS,Resistivity Measurement: 2.5 ?.cm - 49 M?.cm,Resistivity Resolution: 0.1,Salinity Measurement Range: 0 - 42 (ppt) (‰),Salinity Resolution: 0.01 (ppt) (‰),Simultaneous measurements: Yes,TDS Measurement Range: 0.00 mg/L - 50.0 g/L asNaCl,TDS Resolution: 0.01 mg/L - 0.1 g/L upon measuring range,Temperature Compensation: Automatic Temperature compensation for pH,Temperature Measurement: °C or °F,Temperature Range: -10°C - 110 °C,Temperature Resolution: 0.1 Eutech,ThermoScientificOrion, WTW,Hach,Metrohm (with 5 years AMC)
6Pipette Controller Technical Specifications: It will be battery operated electronic pipette filling device and will have Ergonomic design and robust. The pipette must extend smooth operation. The device must have designed to be used for most of the plastic and glass pipettes having volume from 0.1-100 ml. The device must be autoclavable. It will be Light in weight so it can be used forcontinuous operation without fatigue and enablesingle handed operation with minimum efforts. It willhave Dual dispensing with a single knob: Theinstrument will have different modes for dropwise andslow dispensing for fast dispensing). The device willhave continuous pump speed adjustment duringliquid handling operations. It will have replaceable PTFE hydrophobic membranefilter (0.2microns) to prevents aerosol contaminationand accidental liquid entry. Other Technical specifications:Fit: Pipette made of Glass or plasticSize: Pipette of volume size 0.1 ml to 100 mlBattery: Li-On or Ni-Cd batteries,Battery charger: Compatible with both 220V and 110V,Battery indication: Low battery and charging ,indication Operation: Minimum 6 hr continuous operation,Autoclaving Parameters: Autoclavable at 121 °C and 15 psi for a duration of 10-15 minutes. Warranty: 2 yearsMicrolit, Sartorius,Thermo FisherScientific,Brand, Glassco,Borosil
7Turbidity meter(Benchtop)/ (Portable) Range: 0-4000 NTU: Certification: CE, FCC, EC, EN, UL STD,Communication: RS 232, USB via adapter,Compliance: ISO,Data Log: 1000 total logs, includes reading log,verification log and calibration log, Date Time, User ,Display: LCD graphic, backlit, menu controlled,Interface: RS 232, USB via adapter, external printer, barcode scanner, PC ,Light source: Light-emitting diode (IR LED)/ TungstenFilament Lamp,Measurement method: Nephelometric,Operating temperature range: 0 - 50 °C,Power requirements (Voltage): 100 - 240 VAC with Lab station, ,Battery Operated 4 x 1.5 V, type AA for,approx. 3,000 measurements Resolution: 0.001 NTU: Repeatability ±1% of reading or 0.01 NTU whichever is greater Accuracy: ± 2% of reading plus 0.01 NTU from 0 -1000 NTU, ±5% of reading from 1000 - 4000 NTU or better ,Reading Modes: Single, Intelligent Reproducibility and Plausibility Check (IRPC) procedure ,Regulatory: Meets ISO 7027, DIN EN 27027 Response time: (15 seconds 28x60 mm (1.10x2.36 in.), 20 ml sample volume Calibration Point Automatic 3-point calibration Weight approx. 0.6 kg (without batteries),Dimension 236 x 86 x 117 mm,Source Lamp: LED Stabilization time: Immediately,Storage conditions: -20 to 65 °CUnits: FNU and NTU Relative Humidity Yearly mean: ( 75 %: 30 days/year:95 %: Other days: 85 %, Type of Protection: IP 67 (with 5 years AMC)