Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- |
| 2 | Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose. |
| 3 | Disconnecting from over head conductor, cutting worn out portion of LTcables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply.Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately.(ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.Notes for Item Nos 1.01 to 1.02 :-(a)The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b)A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed.(c)The contractor will make suitable arrangement for emergency complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard.(d)The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints.(e)The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad.(f)The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No II store on daily basis. |
| 4 | M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed. |
| 5 | S&F Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FIclamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/taking out old existing unsv stay assembly complete all as specified and directed. |
| 6 | M/L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed. |
| 7 | Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size(Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBsof capacity 315-400 Amps, 4 Pole, 36KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed. |
| 8 | All as per item No-5 here in before but of capacity 250 Amps, 4 pole, 36 KA |
| 9 | All as per item No-5 here in before but of capacity 200 Amps, 4 pole, 36 KA |
| 10 | All as per item No-5 here in before but of capacity 160 Amps, 4 pole, 16KA |
| 11 | All as per item No-5 here in before but of capacity 125 Amps, 4 pole, 16 KA |
| 12 | All as per item No-5 here in before but of capacity 100 Amps, 4 pole, 16 KA |
| 13 | All as per item No-5 here in before but of capacity 63 Amps, 4 pole, 16 KA |
| 14 | S&F MCB, SP 10-32 Amps, \"C\" Curve with breaking capacity 6KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. |
| 15 | Supply and fixing of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off >10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP andand automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 single phase load of 8 KW with circuit wiringmin 10 sq mm copper wire 63 Ampscontactorans suitable MCBs atboth positions at incoming and out goings of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos)for fixing on pole / walllcomplete all as directed including taking down old one .Model no Swadeep-02 EC 8KW 1P or equivalent from Havells/Legrand . |
| 16 | Supply and fixing of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off >10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP andand automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 three phase load of 12 KW with circuit wiringmin 10 sq mm, 3 nos contactor each of 40 - 50 amps, incoming outgoing MCB (3 nos) rating 40 amps of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos)for fixing on pole / walllcomplete all as directed including taking down old one Model no Swadeep-02 EC 12KW 3P or equivalent from Havells/Legrand . |
| 17 | supply and fix Nature switch operation should be based on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off >10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. completeincluding taking down old one. Make swadeepModel Nature switch -02(sensor)/equivalent as approved by GE |
| 18 | supply and fix Nature switch operation should be based on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off >10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. The nature switch to be fiffed in a IP 54 SMC enclosure and protected with MCB SP 10 Amps completeincluding taking down old oneMake swadeepModel Nature switch -02 E (sensor) |
| 19 | S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KVBuilt-in-Surge Protection Device,road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 1.5 Sqmm copperconductor PVC insulated three core weather proof cable etc, fixing to wall/pole, complete all as specified and directed. Note :(i) Contractor has to produce LM-79/LM-80 certificate alongwith purchase vouchers.(ii) External Surge protection of the drive should be 10 KV |
| 20 | All as per item No-11 above but 100 watts. |
| 21 | All as per item No-11 above but 120 watts. |
| 22 | All as per item No-11 above but 150 watts. |
| 23 | All as per item No-11 above but 200 watts. |
| 24 | S&F LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrossion resistant complete with driver and lamp die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 120 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole complete all as specified and directed. Note : (i) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. (ii) External Surge protection of the driver should be 10 KV |
| 25 | All as per item No-12 above but 120 watts. |
| 26 | All as per item No-12 above but 150 watts. |
| 27 | All as per item No-12 above but 200 watts. |
| 28 | Supply, fixing, connecting and testingpost top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity1X35/40 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed. |
| 29 | S&F LED Driver suitable for upto 45 watts LED light fittings complete all as specified and directed. |
| 30 | S&F LED Driver suitable for upto 60 watts LED light fittings complete all as specified and directed. |
| 31 | S&F LED Driver suitable for upto 72 watts LED light fittings complete all as specified and directed. |
| 32 | S&F LED Driver suitable for upto 90 watts LED light fittings complete all as specified and directed. |
| 33 | Supply& replaceLED Driver suitable for100 wattsLED floodlight fittingsof havells make complete all as specified and directed. |
| 34 | Supply & replaceLED Driver suitable for150 wattsLED floodlight fittingsof havells make complete all as specified and directed. |
| 35 | Supply & replaceLED Driver suitable for200 wattsLED floodlight fittingsof havells make complete all as specified and directed. Note for item No.14 to 20:Drivers shall be techincally compitable for existingfittings & frame size shall be matched to existing fittings. |
| 36 | Supply anfd fix locally available gate / garden light of best qualitymetal Silver / metal blackDecorative Exterior of size not less than 300 mm X220 mm with and including LED bulb 9 wattsuitable for outdoor installationandsuitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directedincluding taking down old one . |
| 37 | Material and labour for Taking down UNSV LED Lights and removing Carbon from its connector joints incl replacement of Connecting wire with new PVC sheated weatherproof 3Xsingle core cable for electrical connection and refixing the fittingafter repair to its original/New location or as directed by engr-in-charge.(connecting wire will be measured and paid separately only) |
| 38 | Supply anfd fix locally available Acrylic globe light best quality clear with and including LED bulb 9 watt of 200 mm dia complete suitable for fixing in 40/50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one . |
| 39 | Material and Labour for drawing two runs ofPVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia PVC conduitof dia 20 mm medium gradeexclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clampsetc complete all as specified |
| 40 | S& F LED bulb 5 Wattsuitable for B-22 base holder complete all as specified and directed. |
| 41 | Supply and lay in trenches/fixed to walls/poles etc connecting buy using lugs, testingand commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directed Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately. |
| 42 | All as per item No:26 above but 4 Core 16 Sqmm |
| 43 | All as per item No:26 above but 4.0 Core 25 Sqmm |
| 44 | All as per item No:26 above but 3.5 Core 35 Sqmm |
| 45 | All as per item No:26 above but 3.5 Core 70 Sqmm |
| 46 | All as per item No:26 above but 3.5 Core 95 Sqmm |
| 47 | All as per item No:26 above but 3.5 Core 120 Sqmm |
| 48 | All as per item No:26 above but 3.5 Core 150 Sqmm |
| 49 | Taking out and Relaying of LT cable of size 10 sq mm to 50 Sqmm 2/3.5 coreafter carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugsall as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item) |
| 50 | Taking out and Relaying of LT cable of size 70 sq mm to 150 Sqmm 3.5 coreafter carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugsall as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item) |
| 51 | Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long)including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellowpaint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed.Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. |
| 52 | Restreching/Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree complete all as specified and directed. Notes: (i) The distance between pole to pole in one span (contains 2/4/6 runs) i.e one span will only be considered for payment purpose. (ii) No Extra conductor will be measured for binding to insulators / jumpering etc. |
| 53 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in Hard / Densesoil complete all as specified and directed. |
| 54 | All as per item No 31 above but depth exc 1.5 mtr but not exc 3 mtr. |
| 55 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed. |
| 56 | Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 57 | Spreading riddled earth ( after preparation of excavated earth) inCable duct with sandcushioning of cable laid in trenches complete all as directed by Engineer-in-ChargeNote:- Punned thickness 18 CM( 6.25 Cm below cale and 11.75 cm above cable)will be measured for payment purpose.Quoted rate inclusive of all arrangement as mentioned. |
| 58 | Supply and Laying bricks, common burnt clay building bricks, sub class \"B\" of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed. |
| 59 | M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed |
| 60 | M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed |
| 61 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed |
| 62 | Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. |
| 63 | M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, HDPEpipe medium dutyduty of size 100 mm diain any length including jointing materials to carry LT UG cables of size upto 240 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed. |
| 64 | M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed. |
| 65 | M&L repair/maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed. |
| 66 | M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paintincluding throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed. |
| 67 | M&L for Painting the existing LT PCCpoles with 1 coats of synthetic enamle base paintincluding painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed. |
| 68 | Advance Maintenance Free G.I. SAFE EARTHINGElectrodewith PIPEof not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meterlength, The electrode should be ofgalvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compoundto provide maximum contact between the electrode and Back Fill Compound. .The earting pit should be cover with pcc(1:2:4 , B1) cover ,of450 x 450 mm complete all as specified and directed |
| 69 | Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. |
| 70 | Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premisses/around 2/4 Pole structure/along the boundary fencing and removing rubbish from the site of work complete all as specified and directed. |
| 71 | Supply and fixingsteel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified. |
| 72 | S&F PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed.Make : Richa/havells or equivalent. |
| 73 | All as per item No-50 above but of size 6 Sqmm complete all as specified and directed. |
| 74 | All as per item No-50 above but of size 10 Sqmm complete all as specified and directed. |
| 75 | S&F hot press moulded SMC junction/terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Setincluding dismantling of old unserviceable all as specified and as directed. |
| 76 | Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm. |
| 77 | Supply and laying GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm. |
| 78 | Supply only of aluminium cable lugs of following sizes :- |
| 79 | 16to 25 Sqmm Size |
| 80 | 35to 50 Sqmm Size |
| 81 | 70to 95 Sqmm Size |
| 82 | 120to 150 Sqmm Size |
| 83 | 185to 240 Sqmm Size. |
| 84 | S&F MCCBfactory made enclosure box with neutral link for TPN System made of sheet metal Powder coated Suitable for fixing at Pole including two set of clampsincluding S&F with MCCBTP 100 Amps 16 KA . |
| 85 | Supply and fixing lantren of dia 60 CMfor fixing of flood light,cap type to be fixed on the top of 9 m SP-31 Steel pole , made of MS pip medium gradedia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nosincluding two coat of aliminium painting over a coat of redoxide primer complete all as directed |
| 86 | Supply and fixon wall with necessary arrangements busbar chamber, factory made100 amps 4 way4 polewall mounted IP -54 , made out of 1.6 mmthick CRCA sheet epoxy powder coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Secondincluding necessary cable connectionscompleteall as specified and directed.Note: Quoted rates inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber. |
| 87 | Material and labour for Taking down UNSV LED Lights and removing Carbon from its connector joints incl replacement of Connecting wire with new PVC sheated weatherproof 3Xsingle core cable for electrical connection and refixing the fittingafter repair to its original/New location or as directed by engr-in-charge.(connecting wire will be measured and paid separately only) |
| 88 | Supply&Fixing of Auto/Manual selector swtich in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. |
| 89 | M&L for preparation of old painted surfaces for outdoor/indoor Amf panel/LT Panel of any size with applying two coat of synthetic enamelled grey paint after removing all dust & rust and paint shall confirm to IS 2032complete all as specified . |
| 90 | Dismantling LT steel tubuler pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge. |
| 91 | WATER SUPPLYRepair/rectification of leakages to water supply distribution lines 15 mm bore to 25 mm bore GI/PPR tubing with provision of necessary excavation, cutting of hard standing, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples as required at site complete all as specified and directed. |
| 92 | Allas per item No 62 above but for GI tubing 40 mm bore to 50 mm bore |
| 93 | All as per item No62 here-in-before but for GI tubing 80 mm bore to 100 mm bore. |
| 94 | Attending routine complaintsof external water supply including rectification of minor defects by taking down of existing GI/PPR tubing up to 25 mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement of jumper valve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site complete all as specified and directed. |
| 95 | Allas per item No 65above but for GI tubing 40 mm bore to 50 mm bore. |
| 96 | Attendingcomplaints ofBLOCKAGE OF WATER PIPE LINES / NO WATER SUPPLYAT ANY kind of ACCOMODATION ( MARRIED / OTM/ single / multi storybuilding), IDENTIFY THE FAULTSincluding rectificationby taking down of existing GI/PPR tubing up to 80mm bore, cutting/threading and making joints and cleaning for any blockages, opening of float valve of service tanks, cleaning and fixing the same in its position, replacement ofvalve/ packing sheet of gate valve and including replacement of GI unions/sockets/nipples etc as required at site TO RESTORE WATER SUPPLYcomplete all as specified and directed. Notes for Sl item No 62 to 69 :-(a)The contractor will be allotted complaints at MES complaint cell on requirement basis on all working days including Sundays and holidays and sufficient tradesman / resources will be deployed by him/her for completion of day to day complaints within 12 hours from the time of reporting. Any delay beyond above mentioned time limit without intimation of genuine cause, penalties will be recovered twice of the quoted rate for each un-attended complaint.(b)A detailed log book of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with JE E&M/Engr-in-Charge. (c)The contractor will make suitable arrangement for emergency complaints and will notify authorised representative/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard.(d)The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints.(e)The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad.(f)The contractor will maintain location wise record of each spare/fittings utilized as per inventory format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No IIstore yard on requirement basis.(g)The stationery required for the job work such as complaint slip books, gate pass book, job card and T&P shall be arranged and maintained by the contractor.(h) The cost of excavation / earth work above 1 CUM measured and paid separately under relevant items.j) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution. (k) Spares/GI fittings required to be replaced and shall be measured and paid separately under respective items. |
| 97 | Rectification of leakages in pumping /delivery lines(CI/DI/PPR/MS) of size 80 mm to 100 mmat Military area / Military Roads /civil Roads /PWD Roads /Cantt board roadsby taking necessary permission from respective authorities by excavating PCC/RCC/pavement/soft & hard soil/rock of any depthby using necessary T&P(Excavator/hammer drill)as per the requirement, De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI/ DIspecials such as collars, bends/tail pieces, any type of gasket , welding worketc as required to arrest the leakages completelyand making joints, filling the trenches , site clearances and PCC at the top portion as requiredcomplete all as specified and as directed. Note:-(i)CI specials, lead Joints, D-Joints, Clamp joints, DI/CI Pipe etc shall be measured and paid under respective items of BOQ. (ii) Excavation and PCC will be measured and paid separately under relevant items.(iii) rate of any kind of gasket and Lead joint, necessary barrication for safety of worker etc as required , deemed to be included in the quoted rate.(iii) rate of any kind of gasket and necessary barrication for safety of worker etc as required ,deemed to be included in the quoted rate.(iv) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required.(v) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution. |
| 98 | Taking up or down steel tubing and connections, including cleaning the pipes free from scaling for re-fixing or removal complete with all fittings and connections of the following sizes :- |
| 99 | 15 mm dia |
| 100 | 20 mm dia |
| 101 | 25 mm dia |
| 102 | 40 mm dia |
| 103 | 50 mm dia |
| 104 | 80 mm dia |
| 105 | Refixing of old steel tubing and connection in new or old position including cutting threads if required, fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- |
| 106 | 15 mm dia |
| 107 | 20 mm dia |
| 108 | 25 mm dia |
| 109 | 40 mm dia |
| 110 | 50 mm dia |
| 111 | 80 mm diaNotes for itemNo 70.01 to 70.06 :- (a) Excavation and Earth work shall be measured and paid separately. |
| 112 | Refixing of old steel tubing and connection in new or old position including , cutting threads if required, fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in floors, walls and ceilings and testing for leakages complete all as specified and directed for the following sizes:- |
| 113 | 15 mm dia |
| 114 | 20 mm dia |
| 115 | 25 mm dia |
| 116 | 40 mm dia |
| 117 | 50 mm dia |
| 118 | Supply and laying steel water tubing medium grade, galvanised with all fitting, laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- |
| 119 | 15 mm dia |
| 120 | 20 mm dia |
| 121 | 25 mm dia |
| 122 | 40 mm dia |
| 123 | 50 mm dia |
| 124 | 80 mm diaNotes for itemNo 72.01 to 72.06 :- (a) Excavation and Earth work shall be measured and paid separately. |
| 125 | Supply and laying steel water tubing medium grade, galvanised with all fitting, fixed to wall and ceilings or laid in floor and testing for leakages complete all as specified and directed for the following sizes:- |
| 126 | 15 mm dia |
| 127 | 20 mm dia |
| 128 | 25 mm dia |
| 129 | 40 mm dia |
| 130 | 50 mm dia |
| 131 | Taking up unserviceable/ defective CI/DI/MS/PPRwater mains (including all fitting ) with spigot/ socketed / flanged ends including disconnecting pipes and fittingsin any position complete all as specified and directed for the following sizes:- |
| 132 | 80 mm Dia |
| 133 | 100 mm Dia |
| 134 | 150 mm Dia |
| 135 | Refixing of old CI/DI/MS Pipe and connection in new or old position including fittings with old/new bends, elbows, socket, nipple, tapers, and reducers etc as per site requirement and laid in trenches and testing for leakages complete all as specified and directed for the following sizes:- |
| 136 | 80 mm dia |
| 137 | 100 mm dia |
| 138 | 150 mm dia |
| 139 | S&F ductile iron pressure pipes, class K7, centrifugally cast with spigot and socket ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket D jointing) inany length including DI specials as required at site confirming to IS 8329/2000 and all jointing materials and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and directed for the following sizes:-Notes:- (a)Quoted rates inclusive of Push on Joints/ D-Joints as required (b) The contractor is responsible for obtaining the approval from Police Department for Traffic Diversion and related works if required in consultation with the MES department if required.(c) Contractor is responsible for repair/replacement of any damages to the existing structures, Under Ground HT/LT/OFC Cables etc during the course of execution. |
| 140 | 100 mm Dia |
| 141 | 150 mm Dia |
| 142 | Cutting existing CI pipe line for insertion of new tees, collars for branch connections complete all as specified and directed for the following sizes:-Note: CI /DI specials, Joints and Earth work shall be measured and paid separately under relevant items of this schedule. |
| 143 | 80 mm Dia |
| 144 | 100 mm Dia |
| 145 | 150 mm Dia |
| 146 | Supply only GI fittings 15 mm bore, medium grade, ISI marked, smooth finished and make embossed on fittings complete all as specified and directed for the following fittings:- |
| 147 | Union |
| 148 | All equal Tee |
| 149 | Socket |
| 150 | Nipple 75mm Long |
| 151 | Nipple 100mm Long |
| 152 | Nipple 150mm Long |
| 153 | Plug |
| 154 | Elbow |
| 155 | All as per item No 78 above but for 20 mm bore. |
| 156 | Union |
| 157 | All equal Tee |
| 158 | Reducer Tee 20 x 20 x 15 mm |
| 159 | Socket |
| 160 | Reducer Socket 20 x 15 mm |
| 161 | Nipple 75mm Long |
| 162 | Nipple 100mm Long |
| 163 | Nipple 150mm Long |
| 164 | Plug |
| 165 | Reducer Elbow 20 x 15 mm |
| 166 | Elbow |
| 167 | All as per item No 78 above but for 25 mm bore. |
| 168 | Union |
| 169 | All equal Tee |
| 170 | Socket |
| 171 | Reducer Socket 25 x 20 mm |
| 172 | Reducer Socket 25 x 15 mm |
| 173 | Nipple 75mm Long |
| 174 | Nipple 100mm Long |
| 175 | Nipple 150mm Long |
| 176 | Elbow |
| 177 | Reducer Elbow 25 x 20 mm |
| 178 | Reducer Elbow 25 x 15 mm |
| 179 | Plug |
| 180 | Reducer tee 25mm x 25 mm x 20mm |
| 181 | Reducer tee 25mm x 25 mm x 15mm |
| 182 | All as per item No 78 above but for 40 mm bore. |
| 183 | Union |
| 184 | All equal Tee |
| 185 | Socket |
| 186 | Reducer Socket 40mm x 25 mm |
| 187 | Nipple 75mm Long |
| 188 | Nipple 100mm Long |
| 189 | Nipple 150mm Long |
| 190 | Elbow |
| 191 | Plug |
| 192 | Reducer elbow 40mm x 25mm |
| 193 | Reducer tee 40mm x 40mm x 25mm |
| 194 | Reducer tee 40mm x 40mm x 20mm |
| 195 | Reducer Socket 40mm x 20 mm |
| 196 | Reducer elbow 40mm x 20mm |
| 197 | All as per item No 78 above but for 50 mm bore. |
| 198 | Union |
| 199 | All equal Tee |
| 200 | Socket |
| 201 | Nipple 75mm Long |
| 202 | Nipple 100mm Long |
| 203 | Nipple 150mm Long |
| 204 | Reducer Socket 50mm x 40mm. |
| 205 | Reducer Socket 50mm x 25mm. |
| 206 | Plug |
| 207 | Elbow |
| 208 | Reducer elbow 50mm x 40mm |
| 209 | Reducer elbow 50mm x 25mm |
| 210 | Reducer tee 50mm x 50 mm x 40mm |
| 211 | Reducer tee 50mm x 50 mm x 25mm |
| 212 | Reducer tee 50mm x 50 mm x 20mm |
| 213 | All as per item No 78 above but for 80 mm bore. |
| 214 | Union |
| 215 | All equal Tee |
| 216 | Socket |
| 217 | Reducer Socket 80mm x 50mm. |
| 218 | Reducer Socket 80mm x 40mm. |
| 219 | Nipple 75mm Long |
| 220 | Nipple 100mm Long |
| 221 | Nipple 150mm Long |
| 222 | Elbow |
| 223 | Reducer elbow 80mm x 50mm |
| 224 | Reducer elbow 80mm x 40mm |
| 225 | Reducer tee 80mm x 80mm x 50mm |
| 226 | Reducer tee 80mm x 80mm x 40mm |
| 227 | Supply and fix in replacement of unserviceableGun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed for the following sizes:- |
| 228 | 15mm dia bore |
| 229 | 20mm dia bore |
| 230 | 25mm dia bore |
| 231 | 40mm dia bore |
| 232 | 50mm dia bore |
| 233 | Supply and fix in replacement of unserviceableball brass valves, high pressure with polythene float and fly nut alongwith socket/reducer of suitable size, screwed for iron pipe or brass ferrule and fixedcomplete all as specified and directed for the following sizes:- |
| 234 | 20mm dia bore |
| 235 | 25mm dia bore |
| 236 | M&L for Arrestingleakages of sluice valves by replacing Gland packing, gland bush, gland flange, nut bolts, gasket, packing material as required after dismantling in existing positionincluding testingon completion complete all as specified and directed for the following sizes:-Note: Quoted rates inclusive of the materialsmentioned above like Gland packing, gland bush, gland flange, nut bolts, gasket, packing material etc as required to arrest the leakages. |
| 237 | 80 mm Dia |
| 238 | 100 mm Dia |
| 239 | 150 mm Dia |
| 240 | S&F CI / DIspecials such as bends (any type, radius or angle) tapers any type (Straight, bend, increase, decrease or double socket etc) tee pieces, single \"Y\" branch, double branch cross (all sockets, socket and spigots, collars, cap plugs etc up to 150 mm bore complete all as specified and directed. |
| 241 | Burning out lead joint in position for following sizes of CI/DI pipe, removing old lead complete all as specified and directed :- |
| 242 | 80 mm Dia |
| 243 | 100 mm Dia |
| 244 | 150 mm Dia |
| 245 | M&L for run lead joint for CI pipe/DI pipe includingspun yarn etc for spigot and socket pipes and fittings complete all as specified and directed for the following bore of pipes:- |
| 246 | 80 mm Dia |
| 247 | 100 mm Dia |
| 248 | 150 mm Dia |
| 249 | S&F in repairs CAST IRON ORDUCTILE IRONMECHANICAL COUPLING / MECHANICALJOINT / D JOINTheavy duty INCLUDING ALL JOINTING MATERIAL , ISI marked, split type with long collar, suitable rubber rings, bolts, nuts and washers etc suitable for MS/CI/DI/GI /PVC pipes of following sizes AS REQUIRED FOR REPAIRING OF ANY KIND OF LEAKAGES COMPLETEall as specified and as directed:- Notes:- (a) Excavation and Earth work shall be measured and paid separately. (b) Quoted rate inclusive of cutting of any kind of pipesandall ITEMS as required for fixing and proper functioningofJoints. (c) Quoted rate is deemed to be inclusive of necessary T&P for cutting the pipe line, Pump sets for De-watering, JCB for Excavation (if required) etc and no extra payment shall be admissible on this account. |
| 250 | 80 mm Dia |
| 251 | 100 mm Dia |
| 252 | 150 mm Dia |
| 253 | Supply and fix NRV including making provisions in existing pipeline of CI/DI/MSof the following sizes completed all as directed.Note : Quoted rates inclusive of all arrangement required for the above |
| 254 | 100 mm Dia |
| 255 | S&F, connecting and testing in repair of Cast Iron double orifice kinetic Air Valve ISI Marked IS : 14845 type DK in PN 1.0 flanged end K541 with all standard accessories and testedincluding replacement of nuts, bolts, washers, gaskets, packings etc complete all as per specified and directed. |
| 256 | 100 mm Dia |
| 257 | Cutting the existing road of any kindstraight by manual, depth and width not less than 30 cm for pipes up to 100 mm dia and 60 cm for pipes from 150 mm to 150 mm dia and 75 cm for pipes above 400 mm dia and filling back with excavated soil up to 75 %road portion and 25 % shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate complete all as specified and directed. |
| 258 | M&L for Construction of new PCC solid Masonry valve chamber of size 1500 X 1500 X 1500 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick 150 mm wide off sets around over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, without using extra cement internally including top of floor including excavation earth work in hard/Dense soil 3 mm thick MS sheet cover fixed on 40 mm X 40 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed. |
| 259 | M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, TO CROSS WATER PIPE LINEUP TO200 mm diain any length including jointing materials and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and as directed INCLUDING MAKING GOOD OF DISTURBED SURFACE.NOTE: Pipe will be measured and paid separately under relevant items. |
| 260 | Disconnecting and removing the water and electric connections carefully from the existing submersible pump sets of capacity 3 HP to 10 HP and taking out the pump setalongwith pipes and fittings for flushing the bore wellupto 450 feet depth orrepair the pump set and strip opening the pump set for repairs/replacement of worn out spares, refixing of serviceable spares, assembling the pump set completely, testing of pump set, lowering the pump set inside the bore well after repairs including connecting back the water and electric connections, commissioning of pump set for satisfactory operation on its full load complete all as specified and directed. Note :-The spares required for repair the pump sets and rewinding of motors will be measured and paid seperetely. |
| 261 | M&L for rewinding the Submersible pump Motorwith PVC insulated,super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency inclduing tying the winding and connecting the coils and brining the connections as that of exisitng one including applying insulating varnish, heating and backing the windings thoroughlyincluding taking down old existing copper winding complete all as specified and directed for Submersible pump motor of following capacity :- |
| 262 | Submersible Motor upto and including5 HP. |
| 263 | Submersible Motor above 5 HP up to 10 HP. |
| 264 | Supply and fixing in replacement the following spares suitable for existing make of submersible pump set 3 to 10 HP capacity, multi stage for repairs complete all as specified and directed by Engr-in-Charge :- |
| 265 | Gun metal Impeller. |
| 266 | Stage casing. |
| 267 | SS Sleeves. |
| 268 | Middle bush.(LB) |
| 269 | Middle sleeve. |
| 270 | Discharge outlet.(LB) |
| 271 | Pump coupling. |
| 272 | DOL SS Sleeve. |
| 273 | Suction bush. |
| 274 | Pump Shaft |
| 275 | Supply and replace heavy duty long socket suitable for 50 mm dia heavy duty GI pipe complete all as specified and directed |
| 276 | S&F PVC insulated Copper conductor, sheathed, Submersible flat cables of size 4 Sqmm, 3 core,for Submersible Pumps, 1100 Volts grade, conforming to IS:694/1990 with latest amendments cutting to required length connecting with necessary end ferrules / water proof joints and jointing and testing including disconnecting/taking out old existing cable complete all as specified and directed. |
| 277 | Material labour for removing submerceable pump motor set of capacity up to 10 HP stuck in side the borewell of depth up to 100 meter including byflushingthe existing borewells of any size with drilling compressor mounted on truck at a pressure of 7 Kg / Sqcm with compressed air andflushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh waterand then clear the bore by using Rod drilling using Bore well drilling machine from any kind of obstruction, reinstall the motor and coloumn pipe , necessary electric connection and testingcomplete all as specified and directed .Note; rate quoted by the contractor inclusive of Flushing by using suitable compressure, rod drilling for clearing of bore well, Removingthe submerceable pump set stuck inside the boire well and reinstall the same after repair including removing and refixing of coloumn pipe, electrical connections, testingets as required . |
| 278 | Supply & fixing HDPE heavy duty coloumn pipe in Bore wellinternal dia 50mm PN 16kq/Sqmm including allnecessary fittings and fixtures as requited for fixing with submerceable motorComplete allas specified and directed.Note: Quoted rate inclusive offixing of pipe with submerceable motor and lowring in existing bore well |
| 279 | Supply and fixing of DOL Starter suitable for upto 7.5 HP Motor, 5.5 KW and relay max range 20-32 Amp as in repairs complete all as specified and as directed.Makes : L&T cat part No CS90947 or equivalent of Havells/CG as approved. |
| 280 | Supply and fixing of single phase preventer suitable for upto 7.5 HP motor as in repairs complete all as specified and as directed.Make : L&T cat part No CS94824DOOO or equivalent of Havell/MINILAC |
| 281 | Supply and installation CPRI approved pump starter electric control panel board, for out door use, DOUBLEdoordust & vermin proof floor mounted made out of CRCA steel sheet of 3.15 mm thick angle iron legs of size50x50x5mm, having electrolytic high conductivity insulated bus bar made out of aluminium strips of rating 100 Amps for 3 phase, 415 Volts, 50 C/S 4 wire system, with cable enty jprovision, with suitable lugs gland, voltmeter, Ammeter and phase indicator complete, duly painted with two coats of stove enameled power coated paint over a coat of red oxide primer complete all as including necessary PCC work of height 300 cm from the ground level including disconnecting/taking out old existing unsv pump panel complete all as specified and directed of the following( Leg of the panel should not be less than 0.75 M and size of the panel should not be less than 70CmX60CMX30CM)):-INCOMMING :-(a)MCCB, 4 pole, 415 Volt, 40 Amps, 16 KA - 01 No(b)3 Phase LED Voltmeter, class - 0.5 - 01 No(c)3 Phase LED Ammeter, class -0.5 - 01 No(d)LED Indicator lamp in three colour RYB - 01 SetOUTGOING :-(a)MCCB, 3 pole, 10 KA c Curve 415 volts, 32 Amps -01 No(b) DOL starter in sheet enclosure type MK-1, Motar rating AC-3 duty, 415 volts, 50 Hz suitable FOR 7.5 HP relay max rang 15-25 Amps-01 No.(c) Single hase preventor realy type Sz% (6wire), 415 volts -01 No |
| 282 | Supply and fixBRASS n non return (reflux) valve screwed endwith gun metal seattype of size 50 mm e Kartar/kirloskar/durga/zoloto |
| 283 | Supply and fixContactor 40 amps 3 phase coil operating operating voltage 230 volt make L&t model cs94190 |
| 284 | Supply and fixContactor 25 amps 3 phase coil operating operating voltage 230 volt make L&t model cs94110 |
| 285 | Supply and fixMCB SP&N 32 Amps 10 KA C Curve . Make L&t model BB20320C /Legrand/havells |
| 286 | Supply and fixMCB SP&N 25 Amps 10 KA C Curve . Make L&t model BB20325C/Legrand/havells |
| 287 | M&L for flushingof existing borewells of any sizeupto 150 Mtrs depth with drilling compressor mounted on truckincluding surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air andflushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water including testing of watersamples for chemical and bacteriological tests andcomplete all as specified and directed . |
| 288 | M&L for flushingof existing borewells of any sizeupto 250 Mtrs depth with drilling compressor mounted on truckincluding surging and flushing the bore at a pressure of 7 Kg / Sqcm with compressed air andflushing the sand, mud including flushing out tree roots etc from the bore well till discharge of the fresh water including testing of watersamples for chemical and bacteriological tests andcomplete all as specified and directed . |
| 289 | Serviceaning / periodical checking of Starter panel board suitable for 5 HP to 10 HP Motor by replacing all unserviceable parts , checking for any kind of loose contact , identification of fault etc complete all as specifed and directed . Note : All spare to be replaced and measured under relivent items. |
| 290 | Servicing of Submerceable pump motor set of capacity up to 10 HPcompleteall as directed |
| 291 | Core cutting / drillingof Bldg Roof / Wall for passing of GI Pipe up to 40 mm dia including necessary machineries complete all as specified and directed |
| 292 | Cutting anxious green growth/vegetation growth for cleaning out the area around Pump house/ transformer yard, E/M installations and four pole structure yards at ground level by cutting out roots, un wanted plants bushes and removal of the same by surface excavation not exceeding 30 cm deep average 15 cm complete |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail