}

Tender For Additional/Alternator And Special Repair To Certain Bldg And Provision Of Essential Infra At Base Hospital Guwahati Under Ge Guwahati, guwahati-Assam

Military Engineer Services-MES has published Tender For Additional/Alternator And Special Repair To Certain Bldg And Provision Of Essential Infra At Base Hospital Guwahati Under Ge Guwahati. Submission Date for this Tender is 30-04-2024. Mobile Generator Tenders in guwahati Assam. Bidders can get complete Tender details and download the document.




Tender Notice

42527641
Corrigendum : Tender For Additional/Alternator And Special Repair To Certain Bldg And Provision Of Essential Infra At Base Hospital Guwahati Under Ge Guwahati
Open Tender
Indian
Assam
guwahati
30-04-2024

Tender Details

Tender For Additional/Alternator And Special Repair To Certain Bldg And Provision Of Essential Infra At Base Hospital Guwahati Under Ge Guwahati

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Mar-2024 Date1 Date 30-03-2024
2 23-Mar-2024 date corrigendum2 Date 03-04-2024
3 28-Mar-2024 date corrigendum 3 Date 10-04-2024
4 04-Apr-2024 Date 4 Date 15-04-2024
5 09-Apr-2024 Date corrigendum 5 Date 20-04-2024
6 15-Apr-2024 BOQ BOQ 23-04-2024
7 15-Apr-2024 date corrigendum6 Date 23-04-2024
8 16-Apr-2024 CORRIGENDUM 7 Other 23-04-2024
9 23-Apr-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-04-2024

Key Value

Document Fees
INR 3000 /-
EMD
INR 826500.0 /-
Tender Value
INR 10.03 Crore /-

BOQ Items

Name of Work: ADDN/ALTN AND SPL REPAIR TO CERTAIN BLDG AND PROVN OF ESSENTIAL INFRA AT BASE HOSPITAL GUWAHATI UNDER GE GUWAHATI
Sl. No. Item Description
1Dismantling ceiling boards (Fibre/Pulp/Plywood) of any thickness including cover fillets and removed from site complete all as specified and directed.
2Material & Labour for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having knurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified fixing 4 mm Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed.
3Material & Labour for for false ceiling with 10 mm thick 600mm x 900mm plaster of paris sheets fixed with machine screws on and including GI chanel 18 gauge thick grid work, main joints placed at 750mm center to center, cross joints placed at 450mm center to center, hanging with 6mm dia GI wire suspenders from roof and fixed with "J" hooks bolts and nuts etc and treating the POP sheets with thin layer of POP with gypsum anhydrous binder and perpare the surface till smooth surface is achieved; and applying two coats of plastic emulsion paint over a coat of primer matching with the colour of ceiling sheets all complete as required as per manufacture"s instructions and as directed including dismantling of old unserviceable false ceiling with any type including scantling or the like etc complete all as specified and directed.
4Demolition of brickwork or stone/boulder masonry, built in cement mortar complete all as specified and directed.
5Material & Labour Brickwork with subclass old size ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in Cement Mortar 1:6 complete all as specified and directed.
6Material & Labour Brickwork with subclass old size ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in Cement Mortar 1:4 complete all as specified and directed.
7Taking down plastering on brick work/concrete work in cement mortar complete all as specified and directed.
8Material & Labour for rendering 15 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surface making smooth and even without using extra cement complete all as specified and directed.
9Material & Labour for rendering 10 mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface making smooth and even without using extra cement complete all as specified and directed.
10Material & Labour complete removal of existing treatment on old wall surfaces and applying 1.5 mm thick wall care putty and treating with two coat of plastic emulsion paint including priming coat surfaces of any description over 10cm girth or width, not otherwise described complete all as specified and directed.
11Material & Labour complete removal of existing treatment on old ceiling surfaces and applying 1.5 mm thick wall care putty and treating with two coat of plastic emulsion paint over priming coat on surfaces of any description over 10cm girth or width, not otherwise described complete all as specified and directed.
12Material & Labour preparation of new surface of plastered wall surfaces and applying 1.5 mm thick wall care putty and treating with two coat of plastic emulsion paint over priming coat on surfaces of any description over 10cm girth or width, not otherwise described complete all as specified and directed.
13Material & Labour for preparation of new surface of plastered wall surface and applying finishing walls with Acrylic Smooth exterior paint of required shade two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg /10 sqm including 1.5mm thick wall care putty complete all as specified and directed.
14Material & Labour for complete removal of existing treatment of old plastered or unplastered wall surfaces applying finishing walls with Acrylic Smooth exterior paint of required shade two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg /10 sqm including 1.5mm thick wall care putty complete all as specified and directed.
15Taking down chowkhats or frame with shutter (without taking off shutters from the frame) exceeding 1.5 sqm not exceeding 4 sqm each and removed from site complete all as specified and directed.
16Taking down chowkhats or frame with shutter (without taking off shutters from the frame) not exceeding 1.5 sqm each and removed from site complete all as specified and directed.
17Supply & Fix 2nd class hard wood plain solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
18Supply & Fix 30mm thick solid core construction, with particle board core and plywood face panels, both face is covered with decorative face veneer with lapping/frame to match complete all as specified and directed.
19Supply & Fix 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, (with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, sizes of members of shutters as specified in SSR Part -I. section 8, clause 8.24(a) complete all as specified and directed.
20Material & Labour for preparation of new wooden surfaces of any description,over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint (1st quality) over a priming coat of pink primer complete all as specified and directed.
21Supply & Fix 200 mm long aluminium anodized, barrel tower bolts of extruded section complete all as specified and directed.
22Material & Labour 250 mm long, Aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast, cast section and fixing bolts and sliding bolts of cost aluminium alloycomplete all as specified and directed.
23Supply & Fix 150 mm aluminum handle cast type anodized complete all as specified and directed.
24Supply & Fix 100 mm aluminum handle cast type anodized complete all as specified and directed.
25Supply only mild steel butt hinges of size 100 mm, medium weight cold rolled complete all as specified and directed. .
26Material & Labour Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with Mild Steel Square tube, fixing in opening as per specification & drawingcomplete all as specified and directed
27Material & Labour Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixing in the frame at site as per specification & drawingcomplete all as specified and directed
28Supply & Fix Aluminium Anodised aluminium frame and shutters for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.include handle,tower bolt, door stoper, grill etc. including provision of PVC protected sheeting and its removal after fixing the frame work complete all as specified and directed
29Material & Labour 12mm thick Pre laminated partical board interior grade both sides decorative choice lamination fixed to aluminium frame complete all as specified and directed
30Supply & Fix 12 mm thick frosted toughned glass, ordinary quality and glazing exceeding 0.5 sq. m in each pane including acid pitching work, designing work etc complete all as specified and directed
31Supply & Fix4.8 mm thick Sheet glass, ordinary quality, and glazing in square exceeding 0.5 sq. m in each pane complete all as specified and directed.
32Supply & Fix4 mm thick Sheet glass, ordinary quality, and glazing in square not exceeding 0.5 sq. m in each panecomplete all as specified and directed.
33Supply & Fixbrass 4 levers Mortice lock, vertical type, size 100 mm complete all as specified and directed
34Supply & FixAluminium (Die Cast) body Door closer hydraulically regulated, designation No. 3, universal type,suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
35Supply & FixStainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
36Supply & Fix100 mm Butt hinges, cast brass, with mild steel hinge pin, bright polished, typeB-11 complete all as specified and directed.
37Material & LabourMild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
38Demolition of cement concrete (un-re-inforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
39Demolition of cement concrete (re-inforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
40Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
41Use and waste of formwork to chajjas, weather shades and similar items including edges for rough finishedflat surfaces of concrete complete all as specified and directed.
42Material & LabourMild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
43Material & Labour for Reinforced Cement Concrete 1:2:4 type B0 (nominal mix) (using 12.5mm graded stone aggregate)as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
44Material & Labour for Reinforced Cement Concrete 1:2:4 type B0 (nominal mix) (using 12.5mm graded stone aggregate) as in chajjas complete all as specified and directed.
45Material & Labour for 100mm thick Plain Cement concrete type C- 2, 1:3:6 (using 40mm graded stone aggregate) as in sub-base of floor complete all as specified and directed.
46Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and removing debris and rubbish off the premises complete all as specified and directed.
47Damolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid and pointed in any mortar complete all as specified and directed.
48Material & Labour 25 mm thick Plain Cement concrete B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in sub-base of floor complete all as specified and directed.
49Material & Labour for 75 mm thick Plain Cement concrete type C- 2, 1:3:6 (using 40mm graded stone aggregate) as in plinth protection/ paving complete all as specified and directed.
50Material & Labour for Plain Cement Concrete Type C2 1: 3:6 (using 40mm graded stone aggregate)as in surfaces channels and drains complete all as specified and directed.
51Material & Labour for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, light shade, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15m thick screed bed or bedding layer in CM 1:4 complete all as specified and directed.
52Material & Labour for 20mm thick Granite (of any type) work ( table rubbed and polished) in steps, jambs, pillars,window cills, cooking platforms and and like in 20mm thick bedding layer of cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
53Material & Labour for Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15m thick screed bed or bedding layer in CM 1:4 complete all as specified and directed.
54Material & Labour white Glazed coloured ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed.
55Material & Labour Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
56Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3kg of cement per sqmcomplete all as specified and directed.
57Material & Labour for Plain Cement Concrete Cast-in-situ Type B-1 1:2:4 (using 20mm graded stone aggregate) as in bases for MS posts complete all as specified and directed.
58Supply & FixPre- painted coloured galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
59Supply & FixPre- painted coloured galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
60Supply & FixMild steel framed work of angle or other section as in gusset plates, rails braces, wind ties, cleat, hold fasts etc, complete as required conforming to Fe-290 Gde E-165 complete all as specified and directed.
61Supply & FixSteel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed.
62Supply & Fixwelded steel wire fabric to steel member weight not exc 4 kg/Sqm complete all as specified and directed.
63Material & Labour preparing new steel surface of any description not otherwise described for over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
64Supply & Fixin repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall overall size 915mm x460mm bowl size 410mm x 330mmx160mm complete all as specified and directed.
65Supply & Fixin repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
66Supply & Fixin repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
67Supply & Fixin repair PVC (SWR) pipes, single socketed, in any length, with rubber rings 75mm dia fixed in wall complete all as specified and directed.
68Supply & Fixin repair PVC (SWR) pipes, single socketed, in any length, with rubber rings 110 mm dia laid in floor complete all as specified and directed.
69Supply & Fixin repair PVC (SWR) Bend 110mm dia complete all as specified and directed.
70Supply & Fix1000 litrs capacity rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SS part I including dismantaling and removal from site complete all as specified and directed.
71Material & Labour for Galvanised steel water tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed to wall and ceiling or laid in floors including taking down complete all as specified and directed.
72Disconnecting existing 500 litres tanks, setting aside (or lowering if required) and hoisting if required, reconnecting and re-fixing in position complete all as specified and directed.
73Disconnecting existing 1000 litres tanks, setting aside (or lowering if required) and hoisting if required, reconnecting and re-fixing in position complete all as specified and directed.
74Refixing20 mm steel water Tubing and connections in existing position of floor, wall or ceiling complete all as specified and directed.
75Material & Labour Galvanised steel water tubing 20 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed to wall and ceiling or laid in floors including taking down complete all as specified and directed.
76Supply & Fixin repair single piece-WC of Size 360mm x 640mm x 685mm with PP soft close seat cover, including Hinges, Fixing accessories set and accessories set, Cistern fitting, S trap-110mm complete all as specified and as directed Make-JAQUAR CAT No-SLS-WHT-6851P or equivalent as approved by GE from list of approved makes.
77Supply & Fixin repair Wall Mixer 3-in-1 system with provision for both Hand Shower and Overhead Shower Complete with 115 mm long Bent Pipe, Connecting Legs & wall flange (without Hanh & overhead Shower) all as specified and as directed Make-JAQUAR CAT No-SOL 6281 or equivalent as approved by GE from list of approved makes.
78Supply & Fixin repair Hand Shower 32mm round shape straight design dual flow (ABS Body & face plate chrome plated) with rubit cleaning system with easy flex tube in chrome finish 1.5m long with nuts all as specified and as directed. Make-JAQUAR CAT No-HSH-5541 or equivalent as approved by GE from list of approved makes.
79Supply & Fixin repair overhead shower 120mm dia Round shape single flow (ABS Body chrome plated with Gray face plate) with rubit cleaning systemwith 100mm long shower arm all as specified and as directed. Make-JAQUAR CAT No-OHS--1789 or equivalent as approved by GE from list of approved makes.
80Supply & Fixin repair Single Lever Sink Mixer with 210mm Extension Body Swinging Spout without popup Waste (Table Mounted) with 600mm Long Braided Hoses all as specified and as directed. Make-JAQUAR CAT No-FLR-5009B or equivalent as approved by GE from list of approved makes.
81Supply & Fixin repair 15 mm Angular stop cock with wall flange all as specified and as directed. Make-JAQUAR CAT No-FON-40053 or equivalent as approved by GE from list of approved makes.
82Supply & Fixin repair Table top wall hang basin of size 425mm x 345mm x 175mm with fixing accessories, all as specified and as directed. Make-JAQUAR CAT No-CNS-WHT-903 or equivalent as approved by GE from list of approved makes.
83Supply & Fixin repair Bottle trap (with internal partition) 32mm size with 250mm & 190mm low wall connection pipes & wall flange all as specified and as directed. Make-JAQUAR CAT No-ALD-769L300x190 or equivalent as approved by GE from list of approved makes.
84Supply & Fixin repair 15 mm Bib cock with flange all as specified and as directed. Make-JAQUAR CAT No-ARI-39037 or equivalent as approved by GE from list of approved makes.
85Supply & Fixin repair Hand shower (health faucet)(ABS Body) with 8mm dia, 1.2 meter long flexible tube & wall hook all as specified and as directed. Make-JAQUAR CAT No-ALD-573 or equivalent as approved by GE from list of approved makes.
86Supply & Fixin repair stainless steel toilet paper roll holder all as specified and as directed. Make-JAQUAR CAT No-AKP-35751P or equivalent as approved by GE from list of approved makes.
87Supply & Fixin repair Towel Rack 600mm long with Lower Hangers, Stainless Steel all as specified and as directed. Make-JAQUAR CAT No-AKP-35781PS or equivalent as approved by GE from list of approved makes.
88Supply & Fixin repair Corner Glass Shelf (with Bracket) all as specified and as directed. Make-JAQUAR CAT No-ACN-1173 or equivalent as approved by GE from list of approved makes.
89Supply & Fixin repair reflection looking mirror of size 600x450mm fixed to wall with chromium plated brass screws and cup washers all as specified and as directed. Make PARRYWER Cat No- C 8611 or equivalent as approved by GE from list of approved makes.
90Supply & Fix stainless steel vertical Grab Bar 692 mm Long, Satin all as specified and as directed. Make-JAQUAR CAT No-WAC-SAP-BR0600CS or equivalent as approved by GE from list of approved makes.
91Supply & Fix stainless steel vertical Grab Bar 842 mm Long, Satin all as specified and as directed. Make-JAQUAR CAT No-WAC-SAP-BR0750CS or equivalent as approved by GE from list of approved makes.
92Supply & Fix stainless steel Grab Bar Vertical Swing, Satin all as specified and as directed. Make-JAQUAR CAT No-WAC-SAP-BG0800CS or equivalent as approved by GE from list of approved makes.
93Supply & Fixcore CHD-5 stainless steel door pull handle 32x302x457mm complete all as specified.
94Supply & Fixfloor spring D80 door control lock complete all as specified and directed.
95Supply & FixHospital curtain tracks, made of metal the track is fixed close to wall or ceiling with brackets and curtain gide smoothly along to it complete all as specified and directed.
96Providing and applying a flexible expansion joint membrane minimum 1mm thick, over the prepared joint using a two part thixotropic epoxy adhesive, The expansion joint membrane should be minimum 150mm width and 1mm thickness, the tensile strength of the membrane should be more than 12 N/mm2 and elongation at break should be more than 400%.The installation of the membrane should be carried out as per manufacturers specification or as directed by the Engr-in-Charge.
97Material & Labour for providing and applying three coats of cementitious waterproofing on roof, single component acrylic polymer modified reinforced high build water proofing compound after priming on the roofs, to get a minimum dry thickness of 1mm as per manufacturess specification. No toping required over the grading. The cured membrane should exhibit the tensile strength of 1.1 Mpa as per ASTM D412 with elongation 100% as ASTM D12, with very low penetration to rapid chloride as per ASTM C 1202-03, with pull off adhesion 0.92complete all as specified and as directed.
98Material & Labour drilling suitable holes in RCC slab / wall / column / beams to a depth as directed for anchoring steel reinforcement bars including washing with water, inserting lokfix ‘E’ in the holes as per manufacturer’s instructions complete all as specified and directed upto six storey of building including necessary scaffolding work complete all as specified and directed.
99Material & Labour for providing and cleaning the exposed reinforcement bars thoroughly with wire brushes and emery clothand application of alkaline rust remover Sika rust off 100(Sika)/Reebaklens RR of Fosroc and application of two coats of anti corrosive epoxy Zinc rich Friazinc R (SIKA) or equivalent product like NITOZINC primer of Fosroc on rebars to passivate the corrosion activity on stell as per manufacture’s direction and as specified upto six story of building including necessary scaffolding work complete all as specified and directed.
100Material & Labour for applying a bond coat of epoxy resin based Sikadur-32 LP (SIKA) or equivalent product like NITO Bond EP of FOSROC or Dr Fixit adhesive @ 0.40 ltr per sqm on the cleaned concrete or plastered surfaces by brushes as per manufacturer’s instruction and all as specified upto six storey of building complete including necessary scaffolding.
101Material & Labour for providing and applying a two component structural grade polymer modified reinstatement mortar Fosroc Renderoc S2 or equivalent product of SIKA upto a thickness of 15mm over a epoxy rasin bonding agent Nitobond EP.The cured mortar shall achieve a compressive strength of 12N/mm2 in 1 day & 45 N/mm2 in 28 days with Flexural strength 8N/mm2 in 28 days.Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test.In addition to this percentage of water absorption should be 0.45 after 24hrs in immersion test complete including necessary scaffolding. Note: The testing charges of Accelerated electro chemical chloride ion diffusion test is deemed to be included in the quoted rate.
102Material & Labour for supply, mixing and placement of ready to use non-shrink, comentitious free flow micro-concrete Sika Rep Microcrete-4/renderoc-RG of Fosroc at 50mm thickness as per manufacturers instructions and all as specified upto six storey of building including necessary scaffolding work.Characteristic properties of microconcreteting is having 50 N/mm2 according to ASTM C 109, 70 mm cube, Flexuralstrength after 28 days is 5 N/mm2 according to ASTM C 293-79 including application of curing compound concure WB manufactured by Fosrocor equivalent complete including necessary scaffolding.
103Material & Labour for providing and injecting epoxy grout through 8 mm MS Nozzles using low Viscosity injection resin, Sikadur 53 UF (SIKA)/CONbextra EP-10, two part, solvent free, low Viscosity, moisture insensitive, injection liquid with a positive displacementgrout pump and grouting to be started from lowest level and to proceed towards upper level and to be continued at any Nozzle till refusal / Oozes out from adjacent nozzle or same nozzle.All nozzles shall be removed after 01 day of completion of grouting and hole point to be path repaired by Nitobond PC40 all as per Manufacturer’s direction and as specified upto for 6th storey of building including necessary scaffolding work.
104Material & Labour for providing grouting in RCC walls and slabs by drilling holes @300mm c/c upto half of the wall depth in zigzag manner or as per drawings using a drill machine and fixing a nozzle of 20mm dia, for injecting cement slurry admixed with non shrink admixture using fosroc CEBAX 100 @ 225 gms per bag of cement or equivalent product till the refusal of injected grout material from adjacent nozzle (grouting operation pressure shall be in between 2 to 4Kg per sq cm) followed by cutting the exposed nozzle so as to make the wall free from the grouting pipes and to seal the gap with polymer modified mortar as specified and directed by the Engr-in-Chargecomplete
105Supply & Fixstainless steel ceiling mounted I/V fluid track system of height 18",-24" and 24"-30" with 4 ft and 6ft track and load capacity of 25 Kg complete all as specified and directed.
106Material & Labour forSand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
107Material & Labour for Machine pressed precast conctete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement andpigment complete all as specified and directed.
108Excavation over area not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed.
109Material & Labour for Plain Cement Concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
110Material & Labour for Plain Cement Concrete 1:2:4 (Type B-1) using 20 mm graded stone aggregate in coping, kneelers, apex stones, bed plates, kerbs, water trough and the like including weathering slightly rounded or chamfered angles and throating and necessary formwork complete as specified and directed.
111Material & Labour for brick work with sub class "B" bricks, old size, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and directed
112Material & Labour for Rendering 15 mm thick in Cement Mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
113Material & Labour for Plain cement concrte 1:3:6, type C2 using 40mm graded stone aggregate bed to drain pipes including packing under and haunching against the side of pipes after they are laid and tested for 150mm bore SGSW pipe complete all as specified and directed
114Supply only integral water proofing compound complete all as specified and directed
115Material & Labour for providing precast reinforced concrete M-25 (Design Mix) using 20 mm graded stone aggregate set in CM (1:4) in landing cover slab (for manholes etc), Chullah hoods, chajjas, water troughs, mangers shelves and similar articles with plain faces complete all as specified and directed
116Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
117Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm as in soft/loose soil complete all as specified and directed.
118Removing excavated material (soil) at distance not exceeding 50 m and depositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and as directed.
119Material & Labour for 150mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and as directed.
120Material & Labour for RCC septic tank conventional type for 50 users design to carry sewage and sludge water constructed with RCC M-30 (Design Mix) including PCC below foundation, base slab, baffle walls, roof slab, beams, vent shaft, screening chamber, manhole opening with connection excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/STD-02 sheet No. 1/2 & 2/2
121Material & Labour for soakage well of size 1.8 m dia and 4.5 m effective depth including intercepting chamber and screen chamber made of brick masonary, including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/TD-45, sheet 1/2& 2/2 complete all as specified and directed.
122Cutting into existing manholes for connecting new drain, making good to pipe and rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required (150mm internal dia of pipe) complete all as specified and directed
123Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundations, laying cable or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out in soft/loose soil.
124Material & Labour for Plain Cement Concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
125Excavation in trenches not exceeding 1.50 m wide and exceeding 1.50 m but not exceeding 3.00 m in depth for foundations, etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and exceeding 1.50 m but not exceeding 3.00 m in depth and getting out in soft/loose soil complete all as secified and directed.
126Taking down carefully unserviceable copper/aluminiumpoint wiring (light, fan, socket or power) including unserviceable fittings such as switches, ceiling roses, pendents, regulators, socket, light fittingsetccomplete and making good disturbed surfaces of walls, floors etc.complete all as specified and as directed.
127Material & Labour for providing Point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVCconcealed conduit of adequate size but not less than 20mm in width and 1.2mm thick with all fittings and accessories including modular metal flushbox of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan point controlled by one oneway modular switches including one run 1.5 sqmm (nominal area) PVC insulated flame retardant unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed.
128Material & Labour for providing Point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVCconcealed conduit of adequate size but not less than 20mm in width and 1.2mm thick with all fittings and accessories including modular metal flushbox of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, etc. complete with all fittings and accessories fixed to wall/ ceiling for one 3/5 pin 5/6 Amps modular socket outlet point on same board with other switches including one run 1.5 sqmm (nominal area) PVC insulated flame retardant unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed.
129Material & Labour for providing Point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVCconcealed conduit of adequate size but not less than 20mm in width and 1.2mm thick with all fittings and accessories including modular metal flushbox of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, etc. complete with all fittings and accessories fixed to wall/ ceiling for one 5 Amps 3/5 pin modular socket outlet on independent board including one run 1.5 sqmm (nominal area) PVC insulated flame retardant unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed.
130Material & Labour for providing Point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVCconcealed conduit of adequate size but not less than 20mm in width and 1.2mm thick with all fittings and accessories including modular metal flushbox of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, etc. complete with all fittings and accessories fixed to wall/ ceiling for one module modular bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq.mm size including one run 1.5 sqmm (nominal area) PVC insulated flame retardant unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed.
131Material & Labour for providing Point wiring with 4 sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including PVC concealed conduit of adequate size but not less than 20mm in width and 1.2mm thick with all fittings and accessories including modular metal flushbox of adequate size with suitable modular plate cover for mounting modular switches, sockets, etc. complete with all fittings and accessories fixed to wall/ ceiling for one3/5 pin 15 amp socket outlet including one run 4 Sqmm (nominal area) PVC insulated flame retardant unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly complete all as specified & directed.
132Supply & Fix Modular switch, single pole, one way, 6Amps one module complete all as specified and as directed.
133Supply & Fix Modular 6A, 3 pin universal socket outlet, 2 module complete all as specified and as directed.
134Supply & Fix Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed.
135Supply & Fix Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed.
136Supply & Fix modular bell push with indicator 5 Amps one module complete all as specified and as directed.
137Supply & Fix bell ding dong AC single pole 230 volts complete all as specified and as directed.
138Supply & Fix ceiling rose, 3 point /PVC/polycarbonate, isolated body complete all as specified and as directed.
139Supply & Fix modular stepped type electronics fan regulator 220 Volts, 100Watt/120 Watt suitable for 2 modulecomplete all as specified and as directed.
140Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
141Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
142Supply & Fix 10W environmental friendlyenergy efficient wall mounted LED Bulk head luminaire made of poly carbonate housing withdiffuser, IP65, Efficacy: 100Lm/W including necessary connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
143Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection incl service brakcet to fix the street lightcomplete all as specified and directed.
144Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
145Material & Labour Sub main wiring with 10 Sqmm (Nominal area) with four runs (Red , yellow and blue for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor cables 1100 V grade drawn through and includingPVC concealed conduitof adequate size but not less than 25mm width including 10 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed including taking down old sub main wiring. Note-One run PVC conduit, four runs main cable and one runs of earth wire shall be measured as one unit length.
146Material & Labour Sub main wiring with 6 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor cables 1100 V grade drawn through and includingPVC concealed conduit of adequate size but not less than 25mm width including 6 sqmm (nominal area) single core, PVC insulated, multistranded,unsheathed, FRLS copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed including taking down old sub main wiring. Note- One run PVC conduit, two runs main cable and one run of earth wire shall be measured as one unit length.
147Material & Labour Sub main wiring with 4 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor cables 1100 V grade drawn through and includingPVC concealed conduit of adequate size but not less than 25mm width including 4 sqmm (nominal area) single core, PVC insulated, multistranded,unsheathed, FRLS copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed including taking down old sub main wiring. Note- One run PVC conduit, two runs main cable and one run of earth wire shall be measured as one unit length.
148Supply & Fix in repair Factory made load line Distribution Board 4 way TPN double door fitted with 200 Amps rated busbar suitable for housing MCCBsas incomer(except MCCB) including cutting chasesfor sinking of boxes complete all as specified and as directed.
149Supply & Fix in repair Factory made board distribution in sheet steel enclosure vertical single door with 200 Amps ratedbus bar, TPN, 4 ways, 415 Volts suitable for housing MCBsas incomer and SP MCBsas outgoing complete all as specified and as directed.
150Supply & Fix in repair Factory made board distribution in sheet steel enclosure double door glazed with 200 Amps ratedbus bar, SPN, 8 ways, 230 Volts suitable for housing MCBs complete all as specified and as directed.
151Supply & Fix in repair MCCB,125 Amps four pole 415 volts breaking capacity 25 KA fixed thermal and fixed magnetic setting complete all as specified and as directed.
152Supply & Fix in repair MCB,Four pole,240 volts, 63 Amps 10 KA C curve complete all as specified and as directed.
153Supply & FixRCBOs for earth leakage, overload & short circuit protection32 Amps ,230 Volt50 Hz and 30 MA sensivity complete all as specified and as directed.
154Supply & Fix in repairMCB,SP,240 volts, 6 to 32 Amps 10 KA complete all as specified and as directed.
155Supply & Fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp capacity all as specified and directed.
156Material & Labour, in repair, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SI Part I all as specified and testing on completion includingprovisionof earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note:- Rate quoted by tenderers shall be deemed to include for following provisions- [i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles. [iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd. [v]. GI protection pipe of size 15 mm bore light grade 7.5m.
157Supply & Fix oftest point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 nos, 8mm dia, 25mm long hexagonal headed screws complete all as specified and directed.
158Supply and fixing ofS/S Air curtain of size 6 FEET and speed of air throw at 21 Mtr/Secwith sensor air curtain (2 doors) with contactor complete all as specified and directed
159Supply, testing & commissioning of Nurse Station Display LCD with soft-touch keypad, voice module"Attention Please patient Calling" and power supply of 230 V, AC. One MUTE Button to acknowledge the call from patient It will make flashing window steady and also silence the voice complete all as specified and directed
160Supply, testing & commissioning of Nurse Station Controller (NSC)used to interface with 16 room units & 4 Nurse station Display. It collects information from all the enabled room units and sends information to all the calling units & door indicators. Also sends status to the supervisory controller complete all as specified and directed
161Supply, testing & commissioning ofRoom Unit, Get powerd by Nurse Station Cntroller, consumes less than 5 watts. Allows for 4 pair wires to get inter-connected with NSC, allows4 calling units, 1patient care unit, 1 Toilet calling unit, 1 Door indicator complete all as specified and directed.
162Supply, testing & commissioning of Electronic Calling unit at BED side, uses two feather touch keys one for CALL and other for CLEAR, LED indication for call initiation & acknowledged at Nurse station, Spring Cordwith a keypad having two touch keys - CALL & CLEAR and one indicating LED complete all as specified and directed
163Supply, testing & commissioning of Bi-Coloured Door Indicator, Semi circular plastic housing with two colors of super bright LEDs. Uses for pending call, Nurse presense & normal condition complete all as specified and directed.
164Supply, testing & commissioning of Toilet calling unit with pull-cord, uses one pull cord switch toggle between ON & OFF whenever it is pulled complete all as specified and directed.
165Supply, testing & commissioning of Patient Care Unit, uses three feather keys one for care, one for emergencey call and the other for clear, uses one green LED indicating Nurse presence & another Red LED to indicate that the alarm is active complete all as specified and directed
166Supply, testing & commissioning of Supervisory controller, it is RISC based Micro-controller to get connected to 16 Nurse Station Controllers and to a PC, it interrogates all the NSCs to get information related to all activities of different room units and process them arive at call fowarding, call escalation information which are forwarded to a PC complete all as specified and directed
167Supply, Installation, testing and commissioning of Software, allows management to view various MIS reports like call density, Average respose time, record of escalated Calls, forwarded calls, Calls Profile etc complete all as specified and directed.
168Supply & Laying/fixing of CAT-6 Wiring complete in PVC concealed conduit incl CAT-6 Wire for connection of Nurse calling station complete all as specified and directed.
169Supply, Installation, Testing & Commissioning of ( 8+8) Oxygen manifold extendable type complete with middle frame with chain for individual cylinder (bulk cylinder D type) along with Non-Return valves for every cylinder and high pressure flexible tail pipes and manifold will have 1 brass non return valves for individual oxygen cylinder, middle frame with circumferential M.S. Flat duly colour coated all as specified and as directed manufactured inISO 9001 certified Organization complete all as specified and directed.
170Supply, Installation, Testing & Commissioning of Fully Automatic Digital Gas Control Panel for 02 with following Features: - i) The control panel cover is made using high quality M.S. Duly powder coated. ii) The supply of Gas does not depend on electricity. iii) Display is provided with built-in led to indicate high, normal and low line pressure. iv) Panel cover is fitted with lock to prevent unauthorized access and can be swing open for maintenance. v) It includes pressure gauge (63mm) that indicated the gas pressure of each header and pipe line distribution pressure. vii) Manufactured by ISO -13485 certified organisation. viii) Easy usage and maintenance.
171Supply, Installation, Testing & Commissioning of BS Type Metallic Terminal Units with Double Lock Gas Outlets for Oxygen with probes/ Adaptors conforming to ISO 7396-1:2016 & manufactured by ISO-13485 certified Organization complete all as specified and as directed.
172Supply, Installation, Testing & Commissioning of Oxygen Flow meter, made with chrome plated brass body. Graduated flow tube and cover made of polycarbonate unbreakable. Adjustable flow by needle valve knob with micrometrical regulation. Humidifier bottle is made of unbreakable polycarbonate material and is autoclavable. CE certified complete all as specified and as directed.
173Supply and fixing of oxygenVentilator Probe suitable for system available at site or as specified in BOQ complete all as specified and directed.
174MEDICAL AIR SYSTEM (DUPLEX) Supply, Installation, Testing & Commissioning of CE marked oil free high pressure Air Compressor machine, FAD: 29 CFM driven by TEFC electric motor of 10 HP,Durable cast-iron with two intermediate duty applications including its starter and necessary electrical wiring from connector of air compressor to starter and foundation of compressorcomplete all as specified and as directed.
175Supply, Installation, Testing & Commissioning of 1000 Ltr Air Receiver Tank, 10 gauge thickness with safety valve complete all as specified and as directed.
176Supply, Installation, Testing & Commissioning of Air dryer of capacity 30 CFM complete all as specified and as directed.
177Supply, Installation, Testing & Commissioning of 3 stage Air Filter assembly complete all as specified and as directed.
178Supply, Installation, Testing & Commissioning of pressure reducing system with two nos pressure regulator complete all as specified and as directed.
179Supply, Installation, Testing & Commissioning of BS Type Metallic Terminal Units with Double Lock Gas Outlets for Medical Air ( Air-4 Bar) with probes/ Adaptors conforming to ISO 7396-1:2016. & manufactured by ISO-13485 certified Organization.
180MEDICAL VACUUM SYSTEM Supply, Installation, Testing & Commissioning of CE marked vacuum Pump with accessories, base" mounting. Capacity: 5 HP Duplex 10 HP each Double Stage Vacuum pump including necessary Vacuum accessories Like Silencer,transparent type line VacuumFilter including its starter and necessary electrical wiring from connector of pump to starter and foundation of pump complete all as specified and directed
181Supply, Installation, Testing & Commissioning of 1000 Ltr Air ReceiverTank, and thickness as per manufacturers instruction with safety valveand its foundationcomplete all as specified and directed.
182Supply, Installation, Testing & Commissioning of Ward Vacuum Unit with Regulator along with vacuum gauge, collection jar of 600ml capacity reusable plastic collection bottle with overflow safety tap wall mounted type with bracket complete all as specified and as directed.
183Supply, Installation, Testing & Commissioning of BS Type Metallic Terminal Units with Double Lock Gas Outlets for Vacuum with probes/ Adaptors conforming to ISO 7396-1:2016. & manufactured by ISO-13485 certified Organization.
184Supply, Installation, Testing & Commissioning of Low Pressure flexible transparent Tubing as antistatic tubes complete all as specified and directed.
185Supply and fixing of 12mm OD x 0.7mm Thickness Copper Pipes as per Medical Grade conforming to BS 13348 Llyods certified complete all as specified and directed.
186Supply and fixing of 15mm OD x 0.9 mm Thickness Copper Pipes as per Medical Grade conforming to BS 13348 Llyods certified complete all as specified and directed.
187Supply and fixing of 22 mm OD x 0.9mm Thickness Copper Pipes as per Medical Grade conforming to BS 13348 Llyods certified complete all as specified and directed.
188Supply and fixing of 28 mm OD x 0.7mm Thickness Copper Pipes as per Medical Grade conforming to BS 13348 Llyods certified complete all as specified and directed.
189Supply and fixing of 42 mm OD x 1.2 mm Thickness Copper Pipes as per Medical Grade conforming to BS 13348 Llyods certified complete all as specified and directed.
190Supply, Installation, Testing & Commissioning of Zonal Valve Box, are fully designed to suit multiple operational and requirement and ensure considering space for mounting. The configurations are Valve Boxes are described for 3 Gas Services- 02,Vacuum,Air-4 bar complete all as specified and directed.
191Supply, Installation, Testing & Commissioning of Area Line Pressure Alarm with digital displays for various faults indications and capable of monitoring threemedical gas service( Oxygen, vacuum & Medical air) by means of pressure switches etc. with audible warning with automatic reset when the gas service returns to normal as per standard specifications all as specified and as directed.
192Supply, Installation, Testing & Commissioning Isolation Valves of 12 mm OD with brass body with nickel plate valves operating handle suitable for 15mm OD copper pipe to 76 mm OD copper pipes with brass adapter as per standard specifications all as specified and as directed.
193Supply, Installation, Testing & Commissioning Isolation Valves of 15 mm OD with brass body with nickel plate valves operating handle suitable for 15mm OD copper pipe to 76 mm OD copper pipes with brass adapter as per standard specifications all as specified and as directed.
194Supply, Installation, Testing & Commissioning Isolation Valves of 22 mm OD with brass body with nickel plate valves operating handle suitable for 15mm OD copper pipe to 76 mm OD copper pipes with brass adapter as per standard specifications all as specified and as directed.
195Supply, Installation, Testing & Commissioning Isolation Valves of 28 mm OD with brass body with nickel plate valves operating handle suitable for 15mm OD copper pipe to 76 mm OD copper pipes with brass adapter as per standard specifications all as specified and as directed.
196Supply, Installation, Testing & Commissioning Isolation Valves of 42 mm OD with brass body with nickel plate valves operating handle suitable for 15mm OD copper pipe to 76 mm OD copper pipes with brass adapter as per standard specifications all as specified and as directed.
197Supply and laying or fixing through wall/ pipe etc XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm 3.5 Core.
198Supply & Fix in repair Factory made load line DB 4 way TPN double door fitted with 200 Amps rated busbar suitable for housing MCCBsas incomer(except MCCB) including cutting chasesfor sinking of boxes complete all as specified and as directed.
199Supply & Fix in repair MCCB 3 Pole .415 V. fixed type, 125 Amps with breaking capacity 16 KA.fixed thermal and magnetic setting complete all as specified and as directed.
200Material & Labour forspreading clean dry sand for cable protection/cushioning, in trenches complete all as specified and directed, Note :Consolidated (punned) thickness of sand shall only be measured
201Material & Labour for laying brick sub class "B" old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed.
202Supply and laying/fixing Galvanised steel water tubing 50 mm bore, light grade with all fittings for passing of cables fixed to pole/wall/laid under floor or roads including flat iron clamps of suitable size, with nuts, bolts, etc. for protection of electrical connection cable complete all as specified and as directed.
203Supply, install, commissioning and testing of Air Cooled Screw Chillers ofwith sliding type capacity control, comprising of one or multiple Semi -Hermetic/Hermetic Compressors, DX Evaporator, Shell and Tube Condenser, suitable expansion device,suitable for operation on R - 22/R - 407c/R - 410a/ R - 134a refrigerants and ofcapacity 60 TR (60X2 nos as working and 60X 01 No as s/By) including motor starter unit, in built control panel complete all as directed.
204Supply, installation, testing and commissioning of Monoblock horizontal pumping sets for chilled water circulation system. The pump shall with suitable Starter assy as recommended by OEM of plant & suitable for the given duty points - 3 Nos Each (Out of Three pumps, Two will be working and one will be standby). (i) Water Quantity -115 USGPM (ii) Static Head-20M (iii) Speed -1450 RPM (iv) Impeller- Bronze (v) Shaft- High Tensile steel (vi) Pump/motor body- CI (vii) Seal- Mechanical (viii) Motor - Suitable HP TEFC, 415 Volt, 3 phase, 50 Hz (ix) Starter- Star-Delta (x) Base frame - Fabricated MS
205Chilled water circulation Supply, laying, fixing, testing and commissioning of Chilled water water piping with MS ERW class "C" pipe of size 100 mm dia (Heavy conforming to ISS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, descaling valves. The piping shall be laid overhead in plant and underground outside the plant room as per site conditions complete all as specified and directed
206Chilled water circulation Supply, laying, fixing, testing and commissioning of Chilled water water piping with MS ERW class "C" pipe of size 80 mm dia (Heavy conforming to ISS-1239-1958), complete with all accessories such as bends, elbows, flanges, nut-bolts, air purging valves, descaling valves. The piping shall be laid overhead in plant and underground outside the plant room as per site conditions complete all as specified and directed
207Expansion tank Supply, installtaion, testing and commissioning of PVC Expansion tank of size 1000 ltr capacity complete with duly insulated with 25mm thick Nitrile rubber covered with aluminium cladding omplete with vent and drain connection with flloat valve at the required height to flow the water in to the chiller unit.The cost is also inexclusive of the providing & fixing the MS angle and cost of the fabication to complete work.
208Supply, laying, fixing, testing and commissioning of Balancing Valve 100 mm dia complete all as specified and directed
209Supply, laying, fixing, testing and commissioning of Butterfly Valve 100 mm dia complete all as specified and directed
210Supply, laying, fixing, testing and commissioning of Butterfly Valve 80 mm dia complete all as specified and directed
211Supply, laying, fixing, testing and commissioning of Non Return Valves 100 mm dia. complete all as specified and directed
212Supply, laying, fixing, testing and commissioning of Y Strainers 100 mm dia complete all as specified and directed
213Supply, laying, fixing, testing and commissioning of air surge Valve 15 mm dia complete all as specified and directed
214Supply, laying, fixing, testing and commissioning of Pressure Gauge of 100 mm dial with siphon & isolation valve 0 to 10kg as required. complete all as specified and directed
215Supply, laying, fixing, testing and commissioning of Thermometer complete all as specified and directed
216Supply installation testing and commissioning low density polyethylene drain pipes size 50 mm dia(LDPE) of pressure rating 4 Kg/cm² onwalls/ceiling or laying in floorsincluding fixing with pipe fittings and material as per site requirement complete all as specified and directed
217Supply installation testing and commissioning nitrile rubber insulation 25mm thick on chilled water piping ofsize 100 mm dia complete all as specified and directed
218Supply installation testing and commissioning nitrile rubber insulation 25mm thick on chilled water piping ofsize 80 mm dia complete all as specified and directed
219Supply installation testing and commissioning nitrile rubber insulation 25mm thick on butterfly valve of size 100 mm dia complete all as specified and directed
220Supply installation testing and commissioning nitrile rubber insulation 25mm thick on butterfly valve of size 80 mm dia complete all as specified and directed
221Supply installation testing and commissioning nitrile rubber insulation on balancing valve of the size 100 mm dia complete all as specified and directed
222Supply installation testing and commissioning nitrile rubber insulation on Non Return Valve ofthe size 100 mm dia complete all as specified and directed
223Supply installation testing and commissioning nitrile rubber insulation 25MM thick on ‘Y’ Strainer ofsize 100 mm dia. complete all as specified and directed
224Supply installation testing and commissioning nitrile rubber insulation 25mm thick on 2way balancing valve of suitable capacity complete all as specified and directed
225AIR HANDLING UNITS(AHU) : (Design, Supply, Installation, testing and commissioning Factory made high static double skinned suspended type Air Handling Unit1 [AHU1]7000 CFM (Static Pressure 50WG)with 0.6mm thick pre coated outer skin & 0.6mm thick inner skin made out of GI sheet comprising of backward or forward curved centrifugal blowers of adequate capacity housed in blower section, 3 phase squirrel cage induction motoradequate capacity TEFC type complete with motor pulleys with V-belts. Coil section with cooling coil multi row deep copper tubes with 06 row deep with hydraulically bounded sine wave A1 fins tested for17 Kg/Sqcm pressure Filter section complete with cleanable type prefilter metallic type having efficiency 90% down to 10 micron. The make of cooling coils will be as per manufacturer of AHU. The insulation with 25mm thick PUF panels. The AHUs will be floor mounting with anti vibration pads for cooling the air with all accessories and controls comprising the following including painting etc as per standard practice:- INDOOR TYPE [a] Chilled water cooling coil 6 Row with copper tubes not less than 0.5mm thickness and 13mm over all diameter 10 to 12 aluminium fins per inch. [b] Micro Vee filters having dust filtration capacity of 5 microns and above down to 95%suitable to requisite static pressure with Belt drive flame proof squirrel cage inductionmotor TEFC, 415V, 3 phase, 50 Hz, AC supply class ‘B’ insulation. [c] Electrically controlled / operated controls such as humidistate and thermostat along withall equipment and accessories connection to AHU as per design requirement. [d] Self removable panels with thermal and acoustic insulation. [e] Sloped bottom to collect humidification and condensate water for draining and drainpiping of sufficient size and length as per standard practice. [f] Plenum to house micro vee filters and conical section to connect ducting with flexibleducting (canvas). (j) Acoustic insulation shall be with suitable thickness (not less than 19 mm) elastomeric Nitrile Rubber Open Cell Foam from the mouth of the AHU upto appropriate length as per standard practice. (k) Control for AHU with blower motor, heating thermostat, humidistat etc., with all accessories shall bedeemed to be included as per manufacturer’s specifications.
226(Design, Supply, Installation, testing and commissioning Factory made high static double skinned suspended type Air Handling Unit2 [AHU2]10000 CFM (Static Pressure 50WG)with 0.6mm thick pre coated outer skin & 0.6mm thick inner skin made out of GI sheet comprising of backward or forward curved centrifugal blowers of adequate capacity housed in blower section, 3 phase squirrel cage induction motoradequate capacity TEFC type complete with motor pulleys with V-belts. Coil section with cooling coil multi row deep copper tubes with 06 row deep with hydraulically bounded sine wave A1 fins tested for17 Kg/Sqcm pressure Filter section complete with cleanable type prefilter metallic type having efficiency 90% down to 10 micron. The make of cooling coils will be as per manufacturer of AHU. The insulation with 25mm thick PUF panels. The AHUs will be floor mounting with anti vibration pads for cooling the air with all accessories and controls comprising the following including painting etc as per standard practice:- INDOOR TYPE [a] Chilled water cooling coil 6 Row with copper tubes not less than 0.5mm thickness and 13mm over all diameter 10 to 12 aluminium fins per inch. [b] Micro Vee filters having dust filtration capacity of 5 microns and above down to 95%suitable to requisite static pressure with Belt drive flame proof squirrel cage inductionmotor TEFC, 415V, 3 phase, 50 Hz, AC supply class ‘B’ insulation. [c] Electrically controlled / operated controls such as humidistate and thermostat along withall equipment and accessories connection to AHU as per design requirement. [d] Self removable panels with thermal and acoustic insulation. [e] Sloped bottom to collect humidification and condensate water for draining and drainpiping of sufficient size and length as per standard practice. [f] Plenum to house micro vee filters and conical section to connect ducting with flexibleducting (canvas). (j) Acoustic insulation shall be with suitable thickness (not less than 19 mm) elastomeric Nitrile Rubber Open Cell Foam from the mouth of the AHU upto appropriate length as per standard practice. (k) Control for AHU with blower motor, heating thermostat, humidistat etc., with all accessories shall bedeemed to be included as per manufacturer’s specifications.
227Supply, fabrication, installation, testing and commissioning of galvanised steel sheet (G.S.S.) supply ducting insquare/ rectangular shape fabricated from galvanised steel sheet of 24 gauge galvanized sheet steel having zinc coating of 120 gm/sq.m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 (Revised upto date) all as specified and including with required scafolding work to install the ducts at site complete all as specified and directed.
228Supply, fabrication, installation, testing and commissioning of galvanised steel sheet (G.S.S.) supply ducting insquare/ rectangular shape fabricated from galvanised steel sheet of 22 gauge galvanized sheet steel having zinc coating of 120 gm/sq.m total on both sides complete with gaskets, elbows, splitters, vanes, supports etc. as per IS: 655/1963 (Revised upto date) all as specified and including with required scafolding work to install the ducts at site complete all as specified and directed.
229Supply, laying, fixing, testing and commissioning of Supply Air Diffuser With Volume Control Damper of size 250x200 mm complete all as specified and directed.
230Supply, laying, fixing, testing and commissioning of Supply Air Diffuser With Volume Control Damper of size 200x200 mm complete all as specified and directed.
231Supply, laying, fixing, testing and commissioning of Return Air Diffuser With Volume Control Damper of size 200x200 mm complete all as specified and directed.
232Supply, laying, fixing, testing and commissioning of Return Air Diffuser With Volume Control Damper of size 250x200 mm complete all as specified and directed.
233Supply, laying, fixing, testing and commissioning of Return Air Diffuser With Volume Control Damper of size300x300 mm complete all as specified and directed.
234Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 1200 x 900 mm complete all as specified and directed.
235Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 900x600 mm complete all as specified and directed.
236Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 800x500 mm complete all as specified and directed.
237Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 700x600 mm complete all as specified and directed.
238Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 650x400 mm complete all as specified and directed.
239Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 600x500 mm complete all as specified and directed.
240Supply, laying, fixing, testing and commissioning of Supply Air Grill with Volume Control Damper of size 600x400 mm complete all as specified and directed.
241Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 1100 x 800 mm complete all as specified and directed.
242Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size1000 x 600 mm complete all as specified and directed.
243Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 900 x 600 mm complete all as specified and directed.
244Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 700x600 mm complete all as specified and directed.
245Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 700x450 mm complete all as specified and directed.
246Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 700x400 mm complete all as specified and directed.
247Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 650x500 mm complete all as specified and directed.
248Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 600x500 mm complete all as specified and directed.
249Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 600x450 mm complete all as specified and directed.
250Supply, laying, fixing, testing and commissioning of Return Air Grill with Volume Control Damper of size 450x300 mm complete all as specified and directed.
251Supply, laying, fixing, testing and commissioning of Fire Dampers with Fusible link of size1100x800 mm complete all as specified and directed.
252Supply, laying, fixing, testing and commissioning of Fire Dampers with Fusible link of size 900x600 mm complete all as specified and directed.
253Supply install testing and commissioning of pan humidifier for winter season with connecting pipe with all accessories, valves etc. from tank with necessary heaters and connection wiring complete with humidistat all as directed for 5KW (for AHU 1, 2,). complete all as specified and directed.
254Supply, Install, Testing and Commissioning ofthermostate, humidistat and Air stat for monsoon/winter condition (1 SET each bank) complete all as specified and directed.
255Supply, Installation, Testing and Commissioning of Thermal Insulation for Inside Supplyair ducting with 19mm thick closed cell elastrometric Nitrile rubber withfactory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick3 " wide aluminium foil faced self adesive tape at all joints as per the specifications and approved drawingscomplete all as specified and directed.
256Supply, Installation, Testing and Commissioning of ACCOUSTIC Insulation forSupplyair ducting with 13 mm thick OPEN cell elastrometric Nitrile rubber and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade complete all as specified and directed.
257Supply, Installation, Testing and Commissioning of Thermal Insulation for Inside returnair ducting with 19mm thick closed cell elastrometric Nitrile rubber withfactory laminated aluminium foil of density minimum 43Kg/m3 and fire perfromance to pass Class 1 as per BS 476 Part 7 & class O as per BS 476 part 6 and use recommended adhesives / SR Fevicol 505 grade and finished with 0.05 mm thick3 " wide aluminium foil faced self adesive tape at all joints as per the specifications and approved drawings complete all as specified and directed.
258Supplying, Laying, Testing and Commissioning of XLPE insulated armoured, laid on wall/trench/floor etc, heavy duty electric cable with aluminum conductor, 1100 volts grade, cross-sectional area of size3.5Core X 50 sqmm complete all as specified and directed.
259Supplying, Laying, Testing and Commissioning of XLPE insulated armoured, laid on wall/trench/floor etc, heavy duty electric cable with aluminum conductor, 1100 volts grade, cross-sectional area of size3.5Core X 35 sqmm complete all as specified and directed.
260Supplying, Laying, Testing and Commissioning of XLPE insulated armoured, laid on wall/trench/floor etc, heavy duty electric cable with aluminum conductor, 1100 volts grade, cross-sectional area of size3.5Core X 25 sqmm complete all as specified and directed.
261Supplying, Laying, Testing and Commissioning of XLPE insulated armoured, laid on wall/trench/floor etc, heavy duty electric cable with aluminum conductor, 1100 volts grade, cross-sectional area of size4Core X 10 sqmm complete all as specified and directed.
262Supplying, Laying, Testing and Commissioning of XLPE insulated armoured, laid on wall/trench/floor etc, heavy duty electric cable with aluminum conductor, 1100 volts grade, cross-sectional area of size4Core X 6 sqmm complete all as specified and directed.
263Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor mounting, dust and vermin proof cubical type, CPRI approved, LT panel fabricated from 2.0 mm Indoor type thickCRCA sheet duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top,louvers andair vent gasket fornatural air, `U` shape rubber gasket, voltmeter, ammeter, APFC Relay, Frequency meter. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade suitable for600 ampswith suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance, high strength FRP/SMC/DMC material at an interval not more than 500 mm throughout the length of bus bars,including suitable aluminum earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper copper/ aluminum lugs. The cubical incomer MCCB as well as outgoing shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 500 mm long supported on suitable size `F` class insulator to be provided for termination on incomer and outgoing cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on bottom channel of suitable size with proper mounting arrangement as directed by Engr-in-Charge leaving min 500 mm all around the panel board for movements all as specified with supply and fixing the following:-
264Sr Item No. 263(Contd/..) (A)Incoming - (i) LTMCCB, rating 630 amps, 36 KA, 440 volts 4 pole micro process based with connection of suitable rating by materials Breaking capacity earth leakage protection.1Nos (ii)Digital ampere meter96 x96 mm as per rated capacity of incoming MCCB with suitable CT`s and with 3 way and off rotary type selector switch. .- 01 No. (iii) Digital frequency andpower factor meter -01 Nos (iv)Three indication lamps 22.5 mm diaLED type for three phases with back up protection by 2 Amps MCB.- 2 Sets Note : Amp meter, volt meter and frequency meter should be separate for eachfeeders (B) Out goings (ii) MCCB 160 amps, 4 pole, 415 V AC,50 Hz, ultimate breaking capacity 25 KA , C curve- 04 Nos (APFC panel, and AHU No.1,2 ) (iii) MCCB 100 amps, 4 pole, 415 V AC, 50 Hz, ultimate breaking capacity 25 KA , C curve- 04 Nos (Chillar No.1,2 & 3 .& one spare) (iv) MCB TP 16 Amps, TP, 415 V AC, 50 Hz, ultimate breaking capacity 10 KA ,C curve –03 Nos, 03 Nos chiller Pump. (iv) MCB TP 20 Amps, TP, 415 V AC, 50 Hz, ultimate breaking capacity 10 KA ,C curve –03 Nos, 03 No OUTDOR UNIT VRF . (iv) MCCB FP 63 Amps, 415 V AC, 50 Hz, ultimate breaking capacity 25 KA ,C curve –02 Nos, 02 No DX AHU. Note : (i)Each out going feeders should be provided with digital ampere meter 96 mm x96 mmwith suitable CT`s ratio ( as per the rated capacity of MCCB) with selector switch. (ii)Drawing of LT panel and make of items to be got approved from Engr-in-Charge before procuring the panel. (iii)Cost of lugs for cables and cable gland etc also included in unit rate of panel Board. (iv) All digital meters etc should be protected through proper rated MCB`s. (vi)Supply and Fix DOL starter of suitable capacity forchilled water pump- 03 Nos comprising overload relay, single phase preventer - for motor of pumps (vii) Cost of lugs for cables and cable gland etc also included in unit rate of panel.
265Supply, installation, testing and commissioning of LT, automatic power factor correction (APFC) panel, factory made, weather, dust & vermin proof made out of 16 gauge CRCA steel sheet duly powder coated paint with metalised poly propylene (MPP) type capacitors bank, heavy duty of 80 KVAR with variable correction shall comprise of 03 Nos stepping (1X10+1X20+2x25KVAR). The panel shall have copper bus bar of suitable size, 3 phase and with neutral and with the following:- (a)MCCB, TP, 160 Amps (adjustable type), 25 KA – 01No (incoming) (b) Heavy duty Contactors suitable frequent operation having current limiting resistors suitable for capacitive switching of variable KVAR correction of superior specifications. (c) MCCB/MCBs "C" curve for back up protection of capacity as required. (d) Microprocessor based intelligent APFC relay for controlling variable connection KVAR (e)Indication lamp RYB (LED type) with toggle switch – 03 Set (f) MPP type heavy duty capacitor bank consisting of suitable No of switching sequences, 3 phase, 415 volts suitable for 10% over voltage & 30% over current having loses less than 0.5 W /KVAR with discharge resistors. (g)Suitable Nos & rating of contractors as required. (h)Internal wiring of panel with stranded copper cable of suitable size.
266Supply, installation, testing and commissioning 3 phase and neutral, 415 volts indoor type, factory made free standing, floor/wall mounting, dust and vermin proof cubical type, CPRI tested, LT panel fabricated from 2.00 mm thickCRCA sheet , duly compartmentalized for each switch gear , front and rear open-able ( front hinged opening) ,locking arrangement with chromium plated 19 mm dia fancy locks ( min 2 Nos in each compartment), lifting lugs of suitable size on top,louvers andair vent gasket fornatural air, `U` shape rubber gasket. Panel should be anti corrosive coating and finally epoxy polyester powder coating of Siemens Grey shade (RAL-7032), Protection class IP 43, fully compartmentalized design with 4 Nos of bus bars made of copper of ETP grade for 400 ampswith suitable size of copper strip duly insulated with colour coded heat shrinkable sleeve and shall mounted on suitable size `F` class insulators made of non hygroscopic, non combustible, track resistance , high strength FRP/SMC/DMC material at an interval not more than 500 mm through out the length of bus barsincluding suitable aluminum earth strips, with danger notice plate, necessary cable glands, cable connection with proper aluminum/ copperlugs, The cubical incomer MCCB as well as out going shall have copper TPN extension link of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension link of min 200 mm long supported on suitable side `F` class insulator to be provided for termination on incomer and out going cables. All interconnection between main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual out going feeders. The panel should be mounted on angle iron frame of size 40x40x5 mmand further mounted on PCC foundation and pedestal having min 300 mm all around the feeder pillar board for movements all as specified with supply and fixing the following:- (AHU 1 , AHU2 )
267Sr. Item No. 265 (Contd/...) (A)Incoming - (i) MCCB 160 Amps, 4 pole, 415 V AC, 50 Hz, ultimate breaking capacity 25 KA , Thermal magnetic release with thermal release range 70-125Amp, Ics= 100%Icu -01 No (ii) Digital ammeter of suitable range, 96X96 mm square dial flush type ISI marked with 3 wayselector switch and suitable current transformers 01 Set (iii) Digital Voltmeter 0-500 volts 96 mm x 96 mm square dial flush type ISI marked with3 way selector switch switch -01 set (iv)Three indication lamps 22.5 mm diaLED type for three phases with back up protection by 2 Amps MCB.- 2 Set (B) Out goings (i) MCB 63 Amps, TP, 415 V AC, 50 Hz, breaking capacity 25 KA , Thermal magnetic release- 01 Nos. (ii) MCB 20 Amps, TP, 415 V AC, 50 Hz, breaking capacity 10 KA , Thermal magnetic release- 01 Nos. (For Blower) (iii) MCB 20 Amps, TP, 415 V AC, 50 Hz, ultimate breaking capacity 10 KA , 01 Nos (For Pan humidifier,) (iv) MCB 63 Amps, TP, 415 V AC, 50 Hz, ultimate breaking capacity 10 KA , 01 Nos (For heater,) (v) Internal wiring of panel should be done with single core multi stranded copper conductor cable not less than 2.5 Sqmm / PVC Insulated Copper Stipof suitable size. Note : (i) Drawing of LT panel and make of items to be got approved from Eng-in-Charge beforeordering the panel. (ii)Cost of lugs for cables and cable gland etc also included in unit rate of panel.
268Material & Labour for earthing complete with galvanised steel earth plate electrodesize 600x600x6 mm thick burried directly in groundvertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32x6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 5.00 meter above groung level
269Supply & Fix 40mm dia GI Pipe light grade on wall/floor/trench for cable/earth strip protection with fixing arrangement complete all as specified and directed
270Supply & fix cable route / chilled water pipe route route indicator made of 6mm thick/ 6 inch dia cast iron plate duly embedded with latest LT cable / Chilled water pipe/ Hot water pipe fix in angle in 25mm X 3mm of length 40mm with fix in foundation. Note : PCC & Excavation & Earth work will be measured and paid separately
271Supply & fixEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm dia galvanised iron strip
272Supply & fixEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm diagalvanised steel wire
273Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS -CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening as specified.
274Supply, install, testing and commissioning Fire alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors & 99 modules upto 200 detectors and modulesall as specified in SSR Part-I. Note : (i)The panel shall be fixed outside the building. (ii) Earthing wire 4mm dia for Fire Alarm control panel shall be measured and paid in relevant item.
275Supply & Fix Steel conduit of 25 mm dia on wall, ceiling slab, floor slab stove enammelled rigid steel conduit 25mm dia including provision of conduit acessories like junction boxes, bends, socket, reducers, clip etc. complete all as specified and directed
276Material & Labour for wiring with 2 core armoured 1.5 sqmm XLPE insulated PVC sheathed copper cable for fire decetection circuit with fixing accessories complete all as specified.
277Supply & Fix Addressable type multisensor detector with heat and smoke combination complying with and type certified to EN-45 with base with self built intelligence as per IS-11360 complete all as specified and directed .
278Supply and fix Addressable manual call point resettable type complete all as specified and directed.
279Supply, install, testing and commissioning of siren single stage continuous with control module,normal operation for atleast 50min sound level 65Db to 120 Db measured at 1.5m with sound output variation of +5 Db for 500 mtr rangecomplete all as specified and directed.
280supply and fix remote response indicatorcomplete all as specified and directed.
281Supply and fix short circuit isolatorcomplete all as specified and directed.
282Supply and fix addressable monitor module complete all as specified and directed.
283Supply and fix addressable control module for AHU/FAN Tripping complete all as specified and directed.
284Supply and fix of 3-layer PP-Rpipes of size 32 mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded fittings fixed complete to walls, ceilings or in floors etc including taking down old unsv 25 mm dia GI pipe complete all as specified and directed.
285Supply and fix ofPP-R Gate valves (brass insert) of size 32 mm dia all as per requirement of the siteincluding taking down old unsv 25 mm dia gate valve complete all as specified and directed.
286Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 500 sq mm 3.5 core complete all as specified and directed.
287Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed.
288Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
289Supply and installation of 11kV Compact outdoor substation with non extensible RMU consisting of 1No manually operated 11KV/630 Amps VCB in SF6 insulated stainless enclosure as incomer with of 11 KV single phase, indoor resin castCT/PT combination with CT of ratio as recommended by OEM, class 1.0 / 5P10, burden 15 VA and PT of ratio 11 KV/rt3/110V/rt3/110V/ rt3, class 0.5-3, Burden 50 VA - 50 VA and two nos LBS including other accessories & connecting with IDMT Relay for fault detection and short Ckt protection ,02 Nos 11 KV LBS unit for outgoing in SF6 insulated stainless enclosurewith internal copper bus bars (one for 500 KVA transformer and 01 no for future purpose,1 No of transformer 500KVA,11 KV/433 CRT dry type & associated Lt devices with following accessorie, (i) RYB Phase indicator LED type with protection ACB 800amp 50KA breaking capacity, 01 Set (4 Nos) Bus Bars:Electrolytic high conductivity copperthree phase and neutral busbars rated at 1000 Amps of length as required at site as incoming & outgoing busbar on LT side, insulated with heat shrinkable coloured PVC sleeves & clip on shrouds for joints (ii) ACB with Microprocessor Release IPR 1 + (4 Pole)800 Amps 4 Pole 50 Hz 415 V with thermal magnectic release having rupturing capacity 50 KA - 1Nos (Incoming). (iii) MCCB 200 Amps 4 Pole 50 Hz 415 V, Ics=100% Icu with thermal magnectic release having rupturing capacity 25 KA - 2Nos (Outgoing) (iv) MCCB 320 Amps 4 Pole 50 Hz 415 V, Ics=100% Icu with thermal magnectic release having rupturing capacity 36 KA - 1 No (Outgoing) (v) MCCB 100 Amps 4 Pole 50 Hz 415 V, Ics=100% Icu with thermal magnectic release having rupturing capacity 16 KA - 2Nos (Outgoing) (vi) Onload changeover switch 800 Amps ,4 pole 415 Volt -1 Novii) 3 Phase digital multi function meter modelA, class 1, 5A with relay Vega Series - 1No complete all as specified.
290Supply, laying and tested XLPE insulated, screened, PVC bedded, galvanished steel strip or wire armoured,electric power cables (E) (heavy duty) with aluminium conductor,11000 volts grade,cross sectional area 95 sqmm 3 core complete all as specified and as directed .
291Supply and fix cable jointing kit for 11KV grade cable for outdoor terminationheat Shrink type joint earthed complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable, outdoor type for the size 95 sqmm complete all as specified and as directed
292Supply and fix cable jointing kit for 11KV grade cable for indoor terminationheat Shrink type joint earthed complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable, outdoor type for the size 95 sqmm complete all as specified and as directed
293Steel Tubular Swaged Poles Type 410-SP-55 (11.00 Metre long) complete with cast iron base plate, finial taper plug, cap, mild steel bolts, screws, etc. including applying two coats of black bituminous paint internally and externally upto planting depth and applying two coats of aluminium paint over a coat of aluminium primer (externally from top of PCC copping) including writting MES Pole No. with synthetic enamel paint (first grade quality) complete all as specified. Note:- (a) Earthwork will be measured and paid under appropriate items in Schedule "A" Part-II and PCC will be measured and paid under relevant items in this Schedule. (b) Volume occupied by Steel Pole shall be deducted to derive the quantity of PCC.
294Material & Labour for Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the polecomplete all as specified and as directed.
295Supply & Fix Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade
296Supply & Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size
297Material & Labour for Cross arms, bracings, supports, clamps and back plates abricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
298Material & Labour 150mm dia steel Tubes, "light grade" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
299Material & Labour 100mm steel Tubes, "light grade" galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
300Material & Labour 50 mm steel Tubes, "light grade" galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
301Supply, installation, testing and commissioning of silent type Diesel Engine driven Generating set ISI marked Water cooled type,BHP 200 @ 1500RPM415 volts, 3 phase 4 wire (Engine as per IS: 10001/10002 and alternator as per IS: 13364) meeting the CPBC II Norms complete with foundation as per manufacturer"s recommendation, standard AMF panel with necessary protection and meters including sound proof canopy of capacity 500 KVA with retrofiting for emmision control devicesincluding the following: -(a) ENGINEDiesel engine prime mover of suitable BHP to drive 500 KVA alternator with the following: - (i)Fuel level indicator (ii)Fuel tank of suitable capacity for storing minimum 8 hrs consumption capacity at 75% load. (iii) Fuel inlet arrangement from outside the acoustic enclosure with locking arrangement. (iv) Robust, MS base frame with anti vibration damper pads (v)Continuous 10% overload capacity in every 12 Hrs running. (vi) Self starting with and including suitable maintenance free battery of suitable AH rating as per OEM including charging circuit. (vii) Mechanical or Electronic governor as per OEM.
302Sr. Item No. 299(Contd/..) (b) ALTERNATOR :Alternator 500 KVA at 0.8 PF (lag), 415 volt, 3 phase, 4 wire, 50 Hz, 1500 RPM copper wound with the following: -(i) Self regulated brushless self excitation. (ii)Automatic voltage regulator with band of voltage regulation: + 2.5% of rated voltage. (c) AMF CONTROL PANEL Factory fabricated free standing of suitable size copper bus bar with the following: - (i) MCCB 4 pole, 415 Volt, 3 phase of 800 Amps, 50 KA as per OEM. (ii) Internal wiring with suitable size copper conductor(iii)Start and Stop push button (iv)Digital voltmeter with selector switch (v) Digital frequency meter (vi)Digital ammeter with 3 Nos CT and selector switch (vii) Digital power factor meter (viii)Three phase energy meter (ix) Contactor 4 pole 800 Amps 415 Volt 4 pole - 02 Nos (x)Tripping arrangement with hooter for "High engine temp", "Low lub oil pressure", "High lub oil temp", Low and high engine speed" (xi) entire control circuit etc as per manufacturers" design.(d) ACOUSTIC ENCLOSURE It should be compact, modular construction and approved by ARAI (nodal agency of CPCB) with the following: -(i) Overall noise level less than 75 dB measured at 1 mtr distance in free field condition. (ii)Inside illumination provide with 2 Nos 1 x 9 watt LED light fitting or as per manufacturers" design. Note: - (i) The cost of foundation for installing the DG Setas per manufacturers" recommendation and is deemed to be included in the quoted rate (ii) The cost of installation and necessary electrical connections with accessories likelugs/ nuts bolts/ sleeves/ cable glands of reqd size at siteetcdeemed to be included in the quoted rate (iiii) First filling of fuel (DHPP(N) for 12 hours load test purpose shall be provided and cost deemed to be included in the quoted rate. (iv) Any accessories not mentioned but included in manufacturers standard modules are deemed to be included in the quoted rate.
303Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 coreincluding taking down old U/S ones complete all as specified and directed.
304Supply and Fix Lightning arresters expulsion type 11 KV station class complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and directed.
305Supply and Fix Triple pole Gang operated device 11 KV, 3 pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, forcurrent rating upto 200 amps complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail