| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSHR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLSHR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for group controlled (looped) light point/fan point/ exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLSHR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLSHR PVC insulated copper conductor single core cable etc. as required |
| 4 | Group C |
| 5 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point (Group C) with 1.5 sq.mm FRLSHR PVC insulated copper conductor single core cable in existing surface/ recessed steel/PVC conduit including dismantling as required., with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLSHR PVC insulated copper conductor single core cable etc. as required. |
| 6 | Supplying and drawing following sizes of FRLSHR PVC insulated copper conductor, single core, cable in the existing surface/ recessed steel/ PVC conduit as required.(Rewiring Work as per conduit) Specifications as per IS: 694:1990 (with batch tested and certified by NABL accredited in-house lab as in case required by Engineer-in-charge) |
| 7 | 3 X 1.5 sq mm |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 9 | Bell Push |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 11 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 12 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 14 | Supplying & fixing suitable size GI box with modular plate andcover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \"C\" curve including connections, painting etc. as required. |
| 15 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLSHR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 16 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 17 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 18 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 19 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 20 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 21 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 22 | Supply of 20 watt Extruded Aluminum LED batten (4ft) for surface applicationswith highly efficient LEDs and oppal diffuser and lumens >=110 lum/watt, pf >0.9, CRI>75,Operating voltage range 140 V -270 V , 50000 Hrs Operating hours (Minimum 2 yearsManufacturer Warranty mandatory) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) |
| 23 | Supply of following rating LED flat panel for surface mounting, in CRCA housing, System Lumen Output > 110 lumens/watt, 5700K K pf >0.9, CRI>75, 10kV SPD, Operating voltage range 140 V -270 V LED Lights. (5 years Manufacturer Warranty mandatory) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) |
| 24 | 36 Watt, 2 x 2 (595mm*595mm) LED Panel |
| 25 | 24 W, 1 x 1 (295mm*295mm) LED Panel |
| 26 | Supply of 45W LED Street Light highly efficient made of pressure die cast Alumimium with lens with efficacy > 120 lumens/watt, pf >0.9, CRI>75, 10kV SPD, Operating voltage range 140 V -270 V LED Lightson existing brackets of suitable size on pole/wall including dismounting old fitting. ( 5 years Manufacturer Warranty mandatory ) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) |
| 27 | Supply of 120W LED flood light with robust heat sink along with IP66 protection, secondary lens, efficacy > 120 lumens/watt, 4 kV inbuilt and 10 kV external surge protection including all accessories. ( 5 years Manufacturer Warranty mandatory ) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) |
| 28 | S/I/T/C of 60W of Energy saving Gate light post top , LED including , 10 kV SPD, with all accessories i.e., supply of 1mtr 50mm dia GI pipe, B Class and grouting in the esixting RCC Column and fixing the fiting thereon including connections with 3x1.5sq mm wire, painting etc as required. ( 2 years Manufacturer Warranty mandatory ) All luminaires & drivers shall be BIS registered. ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) |
| 29 | Supply of ALstranded conductor, XLPE Insulated, cores laid up, PVC tape/Extruded Innersheathed for Multicore Cables , Armour (galvanised steel strip), extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988 for following sizes ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) |
| 30 | 2 * 6 sq mm - Aluminium Armoured |
| 31 | 2 * 10 sq mm - Aluminium Armoured |
| 32 | 3 * 16 sq mm - Aluminium Armoured |
| 33 | 3.5 * 70 sq mm - Aluminium Armoured |
| 34 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 35 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 36 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25*3mm MS flat clamp) |
| 37 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 38 | Upto 35 sq. mm |
| 39 | Above 35 sq. mm and upto 95 sq. mm |
| 40 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 41 | Upto 35 sq. mm |
| 42 | Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 meter length along the pole for protection of under ground cable as required. |
| 43 | Provision forlaying DWC pipe of suitable size through manual moling technique under Road and RCC crossings. |
| 44 | Supplying and laying 63 mm dia HDPE DWC pipe ISI marked along with all accessories confirming to IS 14930 part II , complete with fitting and cutting , jointing etc in the existing trench complete as required |
| 45 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). Specifications as Conforming to IS/IEC 60898 ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material) |
| 46 | 6 way , Double door |
| 47 | 12 way , Double door |
| 48 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator). nSpecifications as Conforming to IS/IEC 60898 ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material) |
| 49 | 8 way (4 + 24), Double door |
| 50 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. and dismantling old panel as required. (But without MCB/RCCB/ Isolator) 4 way (4 + 12 ), Double Door. Specifications as Conforming to IS/IEC 60898 ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material) |
| 51 | Supplying and fixing 5 A to 32 A rating, 240 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Specifications as Conforming to IS/IEC 60898 ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material) |
| 52 | Single Pole |
| 53 | Double Pole |
| 54 | Supplying and fixing TPN 63 Amp, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. Specifications as Conforming to IS/IEC 60898 ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material) |
| 55 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required. Specifications as Conforming to IS/IEC 60898 ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material) |
| 56 | 40 A |
| 57 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. Specifications as Conforming to IS/IEC 60898 ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material) |
| 58 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required |
| 59 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Minimum 2 yearsManufacturer Warranty mandatory) |
| 60 | Supply of 300 mmExhaust Fan ,1400 RPM motor with steel body with all accessories suitable for single phase, AC 230 volts,50 Hz supply. (Minimum 2 yearsManufacturer Warranty mandatory) |
| 61 | Supplying and fixing SMC 1 phase Junction Box (with hinged door)on existing Pole/wall with provision for mounting 10 A SP MCB with Neutral Link and earth bolt , 415V AC, 50 Hzconfirming to (Conforms to IS/IEC:60947-1 & 3) with suitable brass glands, thimbles , nuts and boltsincluding making connections and dismantling old boxes as required (240 * 130* 110 mm dimension) (Material suppliedshall bebatch tested and certified by NABL accredited lab as in case required by Engineer-in-charge) (Refer Clause 10 A for testing and quality of material) |
| 62 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLSHR PVC insulated, copper conductor, single core cable and earthing etc. as required |
| 63 | Installation of exhaust/ventillation fan in the existing opening, including making good the damage, connection, testing, commissioningetc. as required. Upto 450 mm sweep |
| 64 | Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give aneven shade, including cleaning of surface with detergent and replacing the damaged rubber reel,painting the pole, nuts and bolts with washers and safety pins, reinstalling the same as required. |
| 65 | Numbering of ceiling fan/ exhaust fan/ Led fittings as required. |
| 66 | Supplying and fixing of atleast 32 mm dia(min.) X 1.50 metres(dia as per light fitting) long G.I. pipe (medium class) bracket for mounting of LED street light/ well glass fitting including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. and dismounting smaller size Pipe as required. GI pipe shall be confirming to IS:1239 PART-1 (2004).(Refer Clause 10 A for testing and quality of material) |
| 67 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 68 | 2 X 6 sq. mm (19mm) |
| 69 | 2 X 10 sq. mm (19mm) |
| 70 | 3 X 16 sq. mm (25mm) |
| 71 | 3½ X 70 sq. mm (38mm) |
| 72 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia using auger including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required ( with batch tested and certified by NABL accredited lab as in case required by Engineer-in-charge). (Refer Clause 10 A for testing and quality of material) . |
| 73 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavati n and re-filling as required. |
| 74 | Supply and installation of MS Enclosure single door system of 400mm* 400mm* 200mm (W*H*D)Fabricated from 2 mm CRCA sheet steel powder coated, mounting plate made up of 2mm galvanised steel, IP 65/IP 66 protection, foamed in PU gasket,>110 deg door openable concealed hinge door with locking arrangement, i/c and o/c cutouts at bottom for cable with rubber bush, with a set of wall mounting brackets and installation of Auto photo switch inside enclosure with all required internal and external wire connections. |
| 75 | Supply of automatic light controller device with 25A load capacity, 230VAC±10% system voltage, 50Hz indoor unit with photo sensor cell along with wire of 5m length for sensing device, with adjustable lux intensity, LED indication, Powder coated sheet metal enclosure for outdoor application. Warranty of 1 years is mandatory. |
| 76 | Fabrication, Supply, Installation, testing & commissioning of Double door, Indoor cubicle type totally enclosed free standing type, moisture, dust and vermin proof Panel Board of minimum size 2m x1.5m x0.4m made out of 2.0 mm thick CRCA sheet Steel IP 54 floor mounting type along with 50x50x6 mm stand upto 45cm height with 16 swg MS sheet covering 3 sides of panel along with all accessories etc as required including masonry works. The sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 85 micron thickness. The board includes415 V electrolytic Aluminum Bus Bar (considering current carrying capacity of 0.8Amp/m2), removable 3mm gland plates,including connection with outgoing feeders completeinall respect. Bus-bar alley and cable alley min 300 mm x 450 mm should be provided with cable terminals with suitable Copper wire, space heater with thermal switch and an LED Lamp shall be provided. Below Accessories are to be provided :-1. Lifting Hooks2. Lovers for ventilation in Cable and Bus bar alley.All MCCB shall have thermal magnetic release as per specification & BOQ. All MCCB\"s shall be with rotary handle & pad locking arrangement. All FP MCCB shall be with solid isolable neutral link.The breaking capacity specified is Ics value. All outgoing MCB\"s shall be C type with 10 KA breaking capacity. The fault withstanding capacity of panel shall be 36 KA rms for 1 sec. The above board shall be complete with 3 nos. LED phase indicating lights, ON/ OFF/ TRIP indication, flush VAF meter with, CT\"s, protective breaker etc. at Incomer with all inter connections by min. 2.5 sq.mm. Copper wires complete in all respect etc as required as per following |
| 77 | 1 no. 320 Amp FP Moulded Case Circuit Breaker. (36 KA) |
| 78 | 4 no. 100 Amp FP Moulded Case Circuit Breaker. (30 KA) |
| 79 | 3 nos. 63 Amp FP Miniature Circuit Breaker. |
| 80 | 6 nos. 32 Amp DP Miniature Circuit Breaker. |
| 81 | 400 Amp FPaluminum bus bar (considering current carrying capacity of 0.8Amp/m2) |
| 82 | Dismantling of old switch sockets,Tubelight fixtures , recessed unservicable conduits ,MCB DBs, GI boxes , end boxes etc |
| 83 | Credit for Dismantled Electrical items : |
| 84 | Scrap metal - switch boxes, MCB DBs , conduit , GI scrap, Main Switchgear Panel Scrap (except MCCBs, RCCBs and 100 A MCBs), O/H pole channel \"AS IS WHERE IS BASIS\" |
| 85 | Scrap Aluminium wiring and cables \"AS IS WHERE IS BASIS\" |
| 86 | Scrap dismantled Fan \"AS IS WHERE IS BASIS\" |