}

Tender For Construction Of Sports Complex And Auditorium With Cafeteria With Electrification At Indira Gandhi Government Medical College And Hospital, Nagpur ., nagpur-Maharashtra

Public Works Department-PWD has published Tender For Construction Of Sports Complex And Auditorium With Cafeteria With Electrification At Indira Gandhi Government Medical College And Hospital, Nagpur .. Submission Date for this Tender is 09-03-2024. Sports Complex Tenders in nagpur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42503585
Tender For Construction Of Sports Complex And Auditorium With Cafeteria With Electrification At Indira Gandhi Government Medical College And Hospital, Nagpur .
Open Tender
Indian
Maharashtra
nagpur
09-03-2024

Tender Details

Construction Of Sports Complex And Auditorium With Cafeteria With Electrification At Indira Gandhi Government Medical College And Hospital, Nagpur .

Key Value

Document Fees
INR 3540 /-
EMD
INR 1372000.0 /-
Tender Value
INR 27.42 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OFSPORTS COMPLEX AND AUDITORIUM WITH CAFETERIA WITH ELECTRIFICATION AT INDIRA GANDHI GOVERNMENT MEDICAL COLLEGE AND HOSPITAL, NAGPUR .
Sl. No. Item Description
1Excavationforfoundationinearth,soilofalltypes,sand,gravelandsoftmurum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthe buildingareaand stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means (A) Lift upto 1.50 m, including transportaion of excavated material
2Excavationforfoundationinearth,soilsofalltypes,sand,gravelandsoftmurum, includingremovingtheexcavatedmaterialuptoadistanceof50metresbeyondthe building area and stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means (B) Lift above 1.50 m to 3.00 m including dewatering & transportaion of excavated material
3Excavationforfoundationinearth,soilsofalltypes,sand,gravelandsoftmurum, includingremovingtheexcavatedmaterialuptoadistanceof50metresbeyondthe building area and stackingandspreadingasdirected,dewatering,preparingthebed forthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 3.00m to 4.0m) By Mechanical Means
4Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0 percent ofclorophyrifos per OneSquareMetreofsurfaceareacoveringtenyears guarantee on bond paper.
5Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at15cmc/casclosetothewallaspossibleandtoinject0.5percentof aldrinor clorophyrifosatthe rate of7.5litresperhole andsealing the same with proper filling and covering 10 years guarantee on bond paper.
6Filling in plinth and floors with contractorsmaterial/brought from outside and approved byEngineer inchargein layers of 15 cmto 20 cm including watering and compactionetc. complete.
7Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm. Layers including watering and compacting etc. complete.
8Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete.
9Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/granite/quartzite/gneissmetalforfoundation/stepsincludingsteelcentering, formwork, laying/pumping, compacting,rougheningthemifspecialfinish istobe provided, finishing uneven andhoneycombedsurfaceandcuringetc.complete.The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only.Newlylaidconcreteshallbecoveredby gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concreteBatch mixplant(Panmixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade)
10(A) GROUND FLOOR
11Providingand layingCast in situ/Ready Mix cement concretein M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windowsmouldedasperdetaileddrawingsorchamferedasapprovedby theEngineer includingsteelcentering, formwork, cover blocks, laying/pumping, compacting , curing , finishing androughening them if special finish is to be provided and curingcomplete.(Excluding reinforcementandstructuralsteel).withfullyautomatic micro processor based PLC withSCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.complete.Withfineaggregate(Crushed sand VSI Grade)
12(A) GROUND FLOOR
13(B) TERRACE FLOOR
14Providing solingusing 80 mmsize trap metal in 15 cm. layer including filling voidswith Crushed sand/grit, ramming, watering etc. complete.
15Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steelcenteringformwork,cover blocks laying/pumping, compactionfinishingtheformedsurfaceswithcementmortar1:3 of sufficient minimumthicknesstogiveasmoothandevensurfaceorrougheningif special finish is to be providedand curing etc. complete. (Excluding reinforcement and structuralsteel).withfullyautomaticmicro processor based PLC with SCADA enabled reversible Drum Type mixer/ concreteBatchmixplant(Panmixer)etc. complete. With fine aggregate (Crushed sand VSI Grade)
16(A) FOR M30 CONCRETE
17Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/gneissmetalforR.C.C.columnsasperdetaileddesignsanddrawingoras directedincludingsteelcentering,formwork,coverblocks,laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to giveasmoothandevensurfaceorrougheningifspecialfinishistobe provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
18(A) GROUND FLOOR
19(B) FIRST FLOOR
20(C) SECONDFLOOR
21(D) TERRACE FLOOR
22Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirectedincludingsteelcentering,formwork,coverblocks, laying/pumping,compactionand roughening the surface if special finish is to be providedandcuringetc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
23(A) GROUND FLOOR
24(B) FIRST FLOOR
25(C) SECOND FLOOR
26(D) TERRACE FLOOR
27ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/ quartzite/ gneissmetal forR.C.C. chajjaas perdetaileddesignanddrawingsincluding steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabled reversibleDrum Typemixer/ concreteBatch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade)
28(A) GROUND FLOOR
29(B) FIRST FLOOR
30(C) SECOND FLOOR
31ProvidingandapplyingrequiredcoatsofawaterbasedEvercreteDeepPenetrating Sealer (DPS) on cement concrete surface like roads, beams, and columns, plastered walls, basements, roofs, potable water tanks etc to react with cement and to penetrate concrete structure thereby making it resistant to chemicals / chlorides water to make it dust proof and to act as a water resistant at the same time which Strengthens the treated surface and reducethecuringperiodetccomplete.-Note--foritemOneNumber7to4prior approval of Superintending Engineer will be necessary
32(A) GROUND FLOOR
33(B) FIRST TERRACE FLOOR
34(C) SECOND TERRACE FLOOR
35Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings includingsteel centering,formwork, coverblocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to beprovidedandcuringetc.complete,(Excludingreinforcementandstructural steel).with fully automatic micro processor basedPLC withSCADA enabledreversible DrumTypemixer/concreteBatchmixplant(Panmixer)etc.complete.Withfine aggregate (Crushed sand VSI Grade)
36(A) GROUND FLOOR
37(B) FIRST FLOOR
38© SECOND FLOOR
39(D) TERRACE FLOOR
40ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-25oftrap/ quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design anddrawings or as directed including steel centering, plywood/ steel formwork, steelprops, laying/pumping,compaction,finishing unevenandhoneycombedsurface with C.M.1:3 of sufficient minimum thickness to give a smooth andeven surface or rougheningthesurfaceifspecialfinishistobeprovidedandcuringetc.complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunnybag,plastic,tarpaulinetc.)withfully automatic micro processor based PLC withSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade)
41(A) GROUND FLOOR
42(B) FIRST FLOOR
43(C) SECOND FLOOR
44Providingand layingCast in situ/Ready Mix cement concretein M-25 of trap/ granite/quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering,formwork,coverblocks,laying/pumping, compactingandroughening them if special finish istobeprovidedandcuringcomplete.(Excluding reinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLC withSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Pan mixer)etc.complete.Withfineaggregate(Crushed sand VSI Grade)
45(A) GROUND FLOOR
46(B) FIRST FLOOR
47(C) SECOND FLOOR
48(D) TERRACE FLOOR
49Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase, newels,chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
50(A) GROUND FLOOR
51(B) FIRST FLOOR
52(C) SECOND FLOOR
53(C) TERRACE FLOOR
54Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
55Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffoldingetc. Complete
56(A) GROUND FLOOR
57(B) FIRST FLOOR
58(C) SECOND FLOOR
59(D) TERRACE FLOOR
60ProvidingSecondclassflyashbrickmasonrywithconventional/I.S.typebricksin cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / twohoopironstrips 25mm x1.60mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete.
61(A) GROUND FLOOR
62(B) FIRST FLOOR
63Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
64(A) GROUND FLOOR
65(B) FIRST FLOOR
66(C) SECOND FLOOR
67(D) TERRACE FLOOR
68Providinginternalcementplaster20mmthickin Singlecoatsincementmortar1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete
69(A) GROUND FLOOR
70(B) FIRST FLOOR
71(C) SECOND FLOOR
72(D)TERRACE FLOOR
73Providinginternalcementplaster6mmthickinasinglecoatincementmortar1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
74(A) GROUND FLOOR
75(B) FIRST FLOOR
76(C) SECOND FLOOR
77(D) TERRACE FLOOR
78Providing and applying Texture plaster with finishing with texture materialof approved makein 3 to 4 millimeterthickness on previously plastered surface, including PlasterGroove6mm thickness or Tape Grooves 35 to 45 mm thickness or as required,inallposition including preparing the surface, scaffolding etc. complete.
79(A) GROUND FLOOR
80(B) FIRST FLOOR
81(C) SECOND FLOOR
82(D) TERRACE FLOOR
83Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles ofspintonesurfacetextureaerolitemakeorequivalentofsize595mm x595mm having15mmthick densified micro look edge and 100% humidity resistance incombustibleasperBS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal levelsuspendedgridofsize600x600mmmadefrom hot dipped G.I. steel sections ionsilhouetteprofile,rotarystitcheddoublewebbed white with 6mm reveal profile (white/black), wherein, mainT runner of size 42mmx14mmbetweenmaintee600mmcenter-tocenterandsecondarycrossTofsize 33x14x0.43mm thick of length 600mm long spaced inter-locked at middleofthefirst crossed T in each panel to form grid of 1200mmx600mm resting onperiphery wall Profile wall section 19mm(7+7) x 19mmx0.40thicknesses and laying false ceilingfor serviceslikediffusers grills includingcutting, makingopeningfor light fittings, fixtures,,smoke detectorsetc.,whereverrequired. MainT runners suspended from ceiling withusing G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mmdiaand 50mmlongdash fastener,4mmdia G.I. adjustablerods with powder- coated/goodqualityG.I.leveladjustmentclips of35x35x0.8mmspaced@1200,center-to- center along main T all complete at all heights as per the specifications, drawings and as per
84(A) GROUND FLOOR
85(B) FIRST FLOOR
86© SECOND FLOOR
87Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, etc complete.
88(A) GROUND FLOOR
89(B) FIRST FLOOR
90(B) FIRST FLOOR
91(B) FIRST FLOOR
92Providing and applyingantipeel paint of approvedmake &approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat,scaffolding, preparing the surface etc. complete (Heat Reflective Paint).
93(A) GROUND FLOOR
94(B) FIRST FLOOR
95(B) FIRST FLOOR
96(C)TERRACE FLOOR
97Providingand applying impression24carratLuxurypaintofapprovedmake& approved brand Emulsion paint to interior walls and ceilings of approved quality, colour and shade to new surfaceintwocoats,includingsubsurfaceprparationbyAcrylic putty and Acrylicprimercoatsincludingscaffolding,preparingthesurface.etc. complete (Low VOC).
98(A) GROUND FLOOR
99(B) FIRST FLOOR
100(C) SECOND FLOOR
101(D) TERRACE FLOOR
102Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre asperdrawing including fixtures,necessarywelding andpainting with one coatsof anticorrosive paint and two coats of oil painting complete.
103(A) GROUND FLOOR
104(B) FIRST FLOOR
105Providing and fixing M.S. grill door 24 Kilogram/ One Square Metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
106(A) GROUND FLOOR
107(H) TERRACE FLOOR
108Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete
109(A) GROUND FLOOR
110Providing andfixing Country cut teak wooddouble or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thickandpanels without ventilator as per detailed drawing excluding the door frame, stainless steelfixturesandfasteningandfinishingthewoodworkwithoil painting 3 coats complete
111(A) GROUND FLOOR
112Solid Core Flush door Single leaf : Providingandfixingfactorymadesolid coreflushdoorinsingleleaf35mmthick, decorative types,ofexteriorgrade,asperdetaileddrawings,conformingto I.S.:2202- 1962(Revised)withapprovedfaceveneersonbothfaceswith/withoutglazingand venetiansinthepositionsshownonthedrawingsorasdirected,allnecessarybeads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing withfrench-polish/ waxing complete. (without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter
113(A) GROUND FLOOR
114(B) FIRST FLOOR
115© SECOND FLOOR
116(D) TERRACE FLOOR
117Solid Core Flush door Double leaf : Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 –1966(Revised)includingapprovedfaceveneersonbothsides,withoutglazingand venetiansincludingmatfinishstainlesssteel fixturesandfastening,stoppersand finishing withfrench polishing etc. (Excluding door frame)(Sample to be gotapproved from Ex. Engineer before use) Commercial Hard Wood shutter
118(A) GROUND FLOOR
119(B) FIRST FLOOR
120Providing and Fixing 32 mm thick One piece single moulded puff ABSTRONE BUTADYNESTYRINE(ABS)Doorshutterforinternaluse includingtoilets madeup ofouter ABS sheet of 1.2 mm thick having puff insulationof35to40Kilogram/One Cubic Metredensity and 10 mm dia.for steel bars 2Nos.,woodenblocktoreceivefixtures,havingM.S.hinges100mmlength,M.S. handles 150 mm length and 10 mm dia sliding door bolt etc. complete
121(A) GROUND FLOOR
122(B) FIRST FLOOR
123Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the testTest MethodSpecified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 "P" Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use
124(A) GROUND FLOOR
125(B) FIRST FLOOR
126Providing and fixing in position aluminium partly openable and partly fixed window of anysize as per detailed drawing and as directed by Engineerincharge with all necessaryalluminiumsectionsincludingnecessaryfixturesand fasteningwith 5mm thick floatglass etc.complete.a)With colour anodizingNoteWhilearrivingatthe rateofitemofitem weight at 6.90 Kilogram/ One Square Metre is considered.
127(A) GROUND FLOOR
128(B) FIRST FLOOR
129Providingandlayinginpositionflooring oftelephoneblack/AmbaWhite/Catbary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete.
130(A) GROUND FLOOR
131(B) FIRST FLOOR
132Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequiredwidthinplain/diamondpatternonbedof1:6C.M.including cementfloat, filling joints with neat cement slurry, curing, polishing and cleaningetc. complete.
133(A) GROUND FLOOR
134Supply & Installation of mapie wood sports flooring as per specification : Providing of 20 mm thick sports flooring, cach individual strip of Hard Maple shall include the engraving of the MFMA (Maple Flooring Manufacturers Association) and manufacturing milf certification number. Minimum width of Hard Maple boards is 57 mm and of random length, verying from 230mm to 1800mm jointed together with the help of tongue and grooye on all four sides of all boards. Substructure of Maple wood shall consist of Softwood batten, Substructure of maple wool flooring shall consist of slooper of spruce or Pine having 63mm- 69mm wiu. (minimum) length between 1220 mm (minimum) cross section of 38 mm (minimum) and laid perpendicular to the main flooring planks at a spacing 305 mm centre to centre, including 9.5 mm (minimum) thick rubber shock pads/cushions at the maximum spacing of 300 mm centre to centre on each sleeper, Vapour Barrier :- 20mm polyethylene membrane installed over the concrete base, beneath the flooring system as a vapour barrier between the conorote and wood floor. GYM Finish :-Machine sanding, one coat of oil modified Poly urethane GYM sealer ánd 2 coats of oil modified Poly urethane GYM sports finishin accordance with manufacturer specification,. AND Game line marki: in accordance with manufacturers specifications and piuject drawing etc complete to the entire satisfaction of Engineer world Badminton Federation. Maple Flooring certified by MFMA ( Maple Flooring Manufactures association)Make :- Connor USA or Equivalent
135(A) GROUND FLOOR
136Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc.OnC.M.1:6includingfillingjointswithpolymerbasefillernosing/mouldingthe sharp edges wherever necessary, curing,etc. complete.
137(A) GROUND FLOOR
138(B) FIRST FLOOR
139(C) SECOND FLOOR
140Providingandfixingmachinecutmachinepolished18mm to20mm thicktelephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaningetc. complete.
141(A) GROUND FLOOR
142(B) FIRST FLOOR
143(C) SECOND FLOOR
144Providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600 mm x 450mm size as per detaileddrawing including vertical bothside polished kadappah stone 25 to 30 mm thick supports with kadappahtop 35 to 40 mm thick and polishedgranite 16to 20mm topwithside stripsofgranite atfront andbothsidesof platform raised with two verticalgranitesupports15cmheightandtopgraniteof 75x40cmincludingcutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m)
145(A) GROUND FLOOR
146Providing andlaying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x590mm to 605mm of8to 10mm thicknessandconfirming to IS.15622-2006 (Group Bla) of approvedmake,shadeandpatternforflooringinrequiredposition laid onabedof1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
147(A) GROUND FLOOR
148Providing andlaying vitrified rustic matt stone finish tileshaving size 590 mm to 605 mm x590mm to 605mm to 8to 10mm thicknessandconfirmingto IS.15622-2006 (Group Bla) of approvedmake,shadeandpatternfordadoandskirtinginrequired position fixed in 1:4cementmortarincluding neatcementfloat,filling joints,curing and cleaning. etc. complete.
149(A) GROUND FLOOR
150(B) FIRST FLOOR
151Providing and laying vitrified matt fininsh tileshaving size 590 mm to 605 mm x to 605 mmof 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approvedmake, shadeandpatternforflooringinrequiredpositionlaidonabed of1:4cementmorar including neat cement float, filling joints, curing and cleaning etc. complete.
152(A) GROUND FLOOR
153ProvidingwaterproofinginW.C.andbathincludingbrickbatcobainallposition includingproviding and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab withwaterproofingcompound@1Kilogram/perbagofcementlaying brickbatcobaof requiredthicknessincm1:5 with waterproofingcompound 1 Kilogram/bagof cementgroutingandfinishingthetoplayerwith20mmthickbrick bedding in cm mortor 1:3 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years" guarantee on requisite stamp paper including curing etc. complete.
154(A) GROUND FLOOR
155(B) FIRST FLOOR
156Providing Water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi-viscous paste prepared by mixing polymer of approved make (such as Master Seal 550/ brush bond / RoffSupercrete / Webercrete / Monobond/Permashield/Hypercrate/MasterCreteM81)andCementin1:2 proportion ( 1 litre polymer : 2 Kg. Cement) to a neatly cleaned anddust free concrete surface and upto 300 mm. over parapet wall prepared by removing loose and deposited materialwithbrushandwater,layingglassfibremeshof10x10specificationof approvedmakeovertackysurface offirstcoatofpolymerfollowedbysecondcoatin transversedirection,sprinklingcoarsesandoverit,followedbyprotectivemechanical cover water proof plaster 20 mm thick after sufficient curing apply IPS 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion using coarse aggregate of 10 MSA and water proofing compoundofapprovedmake andpolypropylene fibres@125gm perbag of cement making groovr 3 to 4 mm wide & 10 mm deepin concrete, in pannels of 3m/4m oraspersitecondition&fillingthejointswithpolysulphidesealantaftercuring includingprovidinghollerwithdripmouldsatthejunctionandfinishingtheconcrete surfacewithneatcementslurry,asdirectedandpondingthesurfaceasdirected etc.complete;covering10yearsguaranteeagainstleakproofnessoncourtFeestamp paper of Rs 100/-
157(A) GROUND FLOOR
158(B) FIRST TERRACE FLOOR
159(C)SECOND TERRACE FLOOR
160Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures andfasteningincludingpipebaseofappropriate diameterandballbase of75mm dia above newel post of 75mmdiameteretc.complete(Priorapprovalofsampleandbrandby Ex.Engineeris necessary before use)
161(A) GROUND FLOOR
162(B) FIRST FLOOR
163Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete or/B.B.masonry and or tying by binding wire etc. complete.
164(A) GROUND FLOOR
165(B) FIRST FLOOR
166(C) TERRACE FLOOR
167Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, ExteriorCompound wall and Gate etc. of cladding processedstonewithmaterialofProcessedclay,Woodenchips,Silicasand,Cement, GFRCadmixtures,Colourpigments,Fiberuptothickof230mm/25mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge)
168(A) GROUND FLOOR
169(B) FIRST FLOOR
170(B) FIRST FLOOR
171Providing and Fixing Sun Louvre panels roll formed, 0.6mm thick, pre-painted stove enameledaluminiumstripofacorrosionresistantalloy,includingnecessary fittingetc. complete, as directed by Engineer in Charge.
172(A) GROUND FLOOR
173(B) FIRST FLOOR
174SupplyandinstallationofcubiclesofwidthanddepthasperAthenaLite-SSSeries Cubicles- Std Sizes (W x D x H): 900 mm x 1550 mm x 2105 mm, (Height is including 100 mm gap from bottom, Door Width- 600 mm specifications/ site drawings). Cubicle heighttobe2105mm.Madefromsolidgradecompacthighpressurelaminateasper IS:2046 and EN-438 manufactured under high specific pressure > 5 MPa and temperature>120°C,Alldoorswillbeofsinglecolourandmadeof12mmthickMerinoHPL compact panel. The doors will have chamfered edges. Each door will be supported by 3 stainless steel made hinges affixed to the pilasters. Size of panels to be as per drawing. HARDWARE&ACCESSORIESareHshaped(Top)headframestructuremadeof extrudedAluminiumgrade6063T5-50micron epoxypowdercoatedforsurface protection, Size to be 125x70x5T.Corner joinery section, Size to be 40x16.5x1.8T. U- ChannelWalljoinerysection,Sizetobe22x16x1.6T.Doorstoppersection,Size tobe 21x12.5x1.6T. Spring loaded Butt Hinges made from Stainless steel grade 304. Surface finish to be matt type. Covers to be lacor coated.etc complete.
175(A) GROUND FLOOR
176(B) FIRST FLOOR
177Full Height Partitions in Glass finishProviding and Fixing 80mm to 85mm thick Full height Double Skin partition up to 3 mtr height with All visible sections in Anodized / Powdercoated finish. Made up of Frames and Tiles. Frame construction In combinaton of Aluminium Rails and Bottom ,Center and Top members, Connected with 2 way Round Shape Post , 3way Post , 4 way Post made up of Aluminium Extruded and Tiles in 5mm thk. NonToughened Glass on bothside. With all the Joints in the partitions covered with PVC extrusions to provide better sound Proofing.Tilestobeseparated55mmfromeachothertoprovideadequatespacefor drawing cablesforelectric,dataandtelephone withproperfacilityforfixing electrical and data switch plates. as per design and drawing.
178(A) GROUND FLOOR
179(B) FIRST FLOOR
180Transportation of material obtained from debris of various sorts including necessary excavation/ loosing including loading, unloading and conveying and disposing as directed. Spec.No.: As directed by Engineer- in-charge.
181Providing andlaying Castinsitu/ReadyMixcement concrete M-15of trap/granite/quartzite/gneiss metal for copingtoplinth or parapet, moulded or chamferedasper drawingorasdirectedincludingsteelcentering,plywood/steel formworkcompacting, rougheningthemifspecialfinishistobeprovided,finishing uneven and honeycombedsurfaceandcuringetc.complete.TheCementMortar1:3 plasterisconsideredforrenderingunevenandhoneycombedsurfaceonly.Newlylaid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
182(A) TERRACE FLOOR
183Providinginternalcementplaster20mmthickin Singlecoatsincementmortar1:4 without neerufinish,toconcrete,bricksurface,inallpositionsincluding scaffoldingandcuring etc.complete.
184(A) GROUND FLOOR
185(B) FIRST FLOOR
186(C) SECOND FLOOR
187PRIVIDING AND FIXING ACOUSTICALFALSE CEILING WITH 0.9 NRC:Sierra Mineral Fibre Acoustical Suspended Ceiling System with 15mm thick Sierra OP Tegular 15/90 Edge Tiles withSuprafine 15mm face exposed grid. The tiles shall have smooth laminatedvisual with Humidity Resistance (RH) of 95%, NRC 0.90(Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 25db as per ASTM E1414, Light Reflectance =86% as per ASTM E-1477, Thermal Conductivity ? = 0.040 W/mK, Colour Global White, Fire PerformanceofclassA2-s1,d0accordingtoEN13501-1with15mmTegular15/90° edge and8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable and classified as ISO 14644-1 cleanroom class 5. It shall be suitable for Green Building application, with Recycled content of 43% and VOC Emissions (French) class of A+. The tile shall have Environmental Product Declaration as per ISO 14025 and EN15804+A2.ThetileshallhavecertificationsfromGRIHAandGreenProthereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid onSuprafine 38 with 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). Thedeflectionloadingofthesystemshallbe12.5kg/m2(asperstandardinstallation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between“cross tee to cross tee” and“cross tee to mainbeam”. All mainbeam to main beam andcrosstee to crosstee connectionshallhave apulloutstrengthofmore than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. Allbordercrosstee/mainbeam shallbelevelledusing perimeterfill.TheTile &Grid systemusedtogethershallcarrya10yearwarrantyagainstmanufacturingdefectand manufacturershallprovideawarrantycertificate.TheTile&Gridshallhavethe manufacturers name embossed/printed on it. The supply shall be backed by a
188(B) FIRST FLOOR
189ACOUSTICALWALLPANELLING–FABRICWRAPPEDOF(SIZE 600X600/1200X25MM):ProvidingandFixingofAcousticalWallPanelwithsquareedgesmadeoffibreglass substrate 25mm thick, wrapped on the front side with an acoustically transparent fabric as pertheapprovedshade(Husk,Copper,Sangria,Sesame,Coffee,Charcoal,Titanium, Flame, Peanut and Shell). The panel shall be classified for Fire Class A, as per ASTM E-84. The Acoustical Wall Panel shall be of sizes 600x600mm (Nominal) or 600x1200mm (Nominal) and shall achieve an NRC of 0.85 (Average value of Absorption Co-efficient readingstakenat250Hz,500Hz,1000Hzand2000Hz)with50mmairgapasper ASTM C423 to be fixed to wall on a framework of wooden battens and using Wall panel Impalers(suppliedby the manufacturer) orby using constructionadhesives(as perthe instructions laid down by the manufacturer). The fibre glass substrate shall have a recycle content of 85%.Installation:Anappropriatevapourbarrier(byothers)shallbeapplied/installedonthe verticalsurfacebeforetheinstallationtoproperlysealagainstentryofanymoisture. Vapourbarrier(byothers)shallbeinstalledasperManufacturer’srecommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface. The Impalers shall be fixed to the battens using self-tapping screws, 3 nos. in case of 600x600mm and 4nos.incaseof600x1200mm.Silicabasedconstructionadhesive(byothers)tobe dabbedontotheprojectingelements(spikes)oftheImpalers.WallPanelsshallbe piercedthroughthe spikes of the Impalers ensuring the line andlevel of the panelsare maintained
190(A) GROUND FLOOR
191(B) FIRST FLOOR
192(C) SECOND FLOOR
193Providing and fixing PARE Linea infratop PVC Wall Pannel with all necessary fittings including scaffolding with approved size, design, & color and foing it in position as per drawing & design (NCSR )
194(A) GROUND FLOOR
195(B) FIRST FLOOR
196(C) SECOND FLOOR
197b)Shutter : Supplying & Fixing of 55mm thick asbestos free criteria checked - fire, heat andsmokeresistantcompositeFirecheckDoorShuttercomplyingwithwithfire performance - FD 120 as per IS:3614 (part - II) comprising of 2x8mm Calcium Silicate boardsoverChemicallytreated(withFireretardantchemicalsinvaccumpressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below15%asperIS:1141)internaltimber(MalaysianHardWood,densifiedto810 Kilogram/cum)frameworkof100x32mmwith32mmthickinfillofceramicfiber (density128Kilogram/cum),vermaculitemixfacedwith3mmFireretardantHigh Densityfibreboard,internallylippedwithhardwoodbeadingandpastedinHydraulic Press under 25 MPa, spray quotedwith 2 coats of in-tumescent paint of minimum 300 micron, and with single row of Brush- Type intumescent strip of size 10mmx4mm affixed on periphery for fire and smoke sealing in the slit on all edges of shutter except bottom, without any external lipping.
198(A) GROUND FLOOR
199c) Vision Panel: 2 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside theshutterstructurewith10mminsidetheshutteronallsideswithU-glazing.An additionalinsulatedpowdercoated"Z"channelof16swgMSsheettobefixedfor reinforcement of the joints.
200(A) GROUND FLOOR
201a)Door Frame: Providing & Fixing Frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm spray quoted with 2 coats of In tumescent paint of minimum 200 micron, with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10mmx4mm concealed in the groove of the Frame for fire and smoke sealing, etc. complete as per direction of Engineer in Charge
202(A) GROUND FLOOR
203Providing and fixing of factory made uPVC Sliding window & door (White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm (+-0.2 mm), duly reinforced with G.I. section 1.5 mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the testTest MethodSpecified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 "P" Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5 mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM / TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window / Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non-uniform discoloration, wrapping and rotting under general use
204(A) GROUND FLOOR
205(B) FIRST FLOOR
206Providing andfixing inposition(asper1868/1982)Aluminium sliding windowof three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbeof bearingbottom40x18x1.25mmat weight 0.417Kilogram/One Running Metre. Inter locking section 40x 18x 1.10mm atweight0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm at weighto.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirected byEngineerinchargewithallnecessaryAluminiumsectionsfixturesandfastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section ofshutter including 5 mmthickplainglassandaluminiummosquitonetshutterwith stainlesssteeljailwithall required screws and nuts etc, complete. With powder coating with box
207(A) GROUND FLOOR
208(B) FIRST FLOOR
209Providing andfixing in positionPhenol bondedBamboo woodflooring withplanks of sizes 14mm thick, 1800 mm length (minium) and 130 mm wide (minimum), in approved colour,textureandfinish,havingPerformanceAppraisalcertified(PAC)issuedby Building Materials&TechnologyPromotionCouncil(BMTPC).Theflooring shallbe fixedwithtongueandgrooveinterlockingsystem,withunderlaymentof4mmthick expandedpolyethylenefoamsheetshavingdensity40kg/OneOneCubicMetre,over prepared surface with necessary quarter round planks of size 1900mm x 18mm and door reducerofsize 1900mm x44mm,whereeverrequired.The bamboowoodplanksshall have minimum density of 1000 kg/One One Cubic Metre & minimum Hardness 1000kgf. withEcofriendlyUVcoating,allcompleteasperdirectionofEngineerin-charge. Ground floor
210(A) GROUND FLOOR
211Providing,layingand fixingexteriorgradefibrillingfibrereinforcementheavyduty designer cementconcrete tilesforFlooring ofapprovedcolour anddesign 22+/ -2 mmthick bayercolour pigmented as per IS ..1237 - 1980 having compressive strengthmorethan500 Kilogram/sq.cmreaffirmedin2006,havingwerttransvrse strenghthof3.5/mm2,water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than 25.0(ASTM:E303)andnofadingasperDIN-51094ofsize300x300 inplan/ designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring.
212(A) GROUND FLOOR
213ProvidingandlayingVitrifiedMATTfinish havingdecorativetypeofsize1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical andconfirmingtoIS15622-2006(GroupBla)ofapprovedmake shade and pattern forflooring in required position laid on a bed of bonding chemicalfillingjointscuringand cleaning etc .complete.
214(A) GROUND FLOOR
215(B) FIRST FLOOR
216Providingandlayingcementconcreteflooring 40mm thickwithM20cementconcrete laidtoproperlevelandslopeinalternatebays,includingcompaction,fillingjoints, markinglinestogiveappearanceof tiles of 30cmx 30cmorother sizelaid diagonally/square etc.finishing smooth (with extra cement) in any colour as directed and Curing etc. complete. With Crushed sand VSI Grade
217(A) GROUND FLOOR
218Providing & Fixing in position, Carpet more than 800+ gsm, made with100% stain proof fibres of approved make along with 5mm underlay as per Architectural & Acoustical Design & Instructions & Complete in all aspects including all materials labour,finishing etc complete
219(A) GROUND FLOOR
220Providingandfixing900mmhighS.S.304GradeStainlesssteelrailingwith40mm diameter and1.5mmthickattop,40mm diameterand1.5mm thickverticalsupports spaced at 1.5mcenter to center and 8mm thick toughened glass including fabricating ,fixtures, errecting ,necessarywelding,grinding,finishing,buffingto stainless steel pipe etc. complete
221(A) GROUND FLOOR
222(B) FIRST FLOOR
223(C) SECOND FLOOR
224Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/ One SquareMetre as per drawing including fixtures necessary welding and painting withonecoatof anticorrosive paint and two coats of oil painting complete.
225(A) GROUND FLOOR
226(B) FIRST FLOOR
227SupplyandInstallationoftranslucentroofwithDPIFluxstandingseammulticell polycarbonatepanelsystem.ThesystemwithcompleteassemblyofcoextrudedUV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angulardaylightingconcept.Panelsshallhaveminimumsixlayerswithtrussbridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlinwithsnap on connectors withdouble tooth grip lock locking mechanism and willbesecuredonMSstructure(willbepaidSeparately)with3OneNumbersself- drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as perENISO10077-2:2018.PanelshallbewithadditionalEndcap/AluminiumU/F profile/GlazingBarforendsasrequired.PanelshallbefixedoverMSstructural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge.Colour:AsperApproval.ApprovedMake:FLUXbyDPIDaylightingor approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs.
228(A) GROUND FLOOR
229Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt. totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550MPayieldstrength, metallic hot dip coated with Aluminium-Zinc alloy (55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganicpigment).Thepaintshallhaveatotal coatingthicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface andnominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center.The endribshallbe designedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturersproductdetailsmarkedaregularinterval.Includingfastenerswithmin. fastenedwithmin.25umZinc-Tinalloycoated,Hexhead,self-drillingscrewetc. complete. (weight of profile 4.52 Kilogram/ One Square Metre)
230(B) FIRST FLOOR
231Providing,fabricatinganderecting atsiteofworkthetubularsteelstructure(shed) asper standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive ofcostofsteeltubulartrusses,tubularcolumnspurlins,tierunners,foundation bolts, base plates, nuts and bolts,weldingwhereverrequiredetc. asperdetaileddrawing inclusiveofonecoatof anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. One Number : As directed by Engineer-in-charge.
232(A) GROUND FLOOR
233(B) FIRST FLOOR
234CNC CUTTING ON HPL PANEL
235(A) GROUND FLOOR
236(B) FIRST FLOOR
237Providing and fixing BIFMA Certified Auditorium Chair (Box office -Symphony Model), BOX-OFFICE SYMPHONY is a Push Back chair with writing tablet and Fluimatic slider system. STRUCTURE:- Frame :Back Rest frame of ERW Tube / IS:3074-2005 GRADE 1-16 dia Round Pipe 1.2mm Thickness & Extra Reinforcement 16 dia round pipe 1.2 mm. Cushion Frame (Seat) ERW Tube/IS:3074- 2005 GRADE 1-22 dia Round Pipe 1.63mm Thickness. WING COMPONENTS:-a) Side wing frame with plywood, with upholstery. b) Leg: sq TUBE IS:4923-1997-25X25 mm, 1.63 Thickness SPRINGS:-Seat: For Auto Tip-up-Torsion Spring/ Spring Steel IS: 4454 11981 GRADE 3 (part i) Tested for 5,00,000 cycles. For Push Back mechanism - Coil spring / Spring Steel IS: 4454 1981 GRADE 2 Tested for 1,00,000 Cycles. FOAM:-Automotive Grade High Resilence-HR Polyurathene foam, Density: 50+5 Kg/M3/IS K 6401, Constant Compression Set: (Max. 13%) JIS K 6401. BACK AND CUSHION HOUSING:- PPCP IS: 10915 1994./ Injection Molded/Thermoform Plastic. FINISH:- Seat Cushions Dimensions are in-line with Anthropometric Datas & Ergonomically profiled Contours. BACKHEIGHT:- Height of top of the back from ground level 1030 1+/-15mm. EFFECTIVE SEAT DEPTH:- Seat Cushions Dimensions are in-line with Anthropometric Datas & Ergonomically profiled Contours. Seat depth is 475mm land 448mm width & height from ground level 435mm tipe of back rest slider160mm travels. With metal ball and roller cage which results in PUSH BACK OF 140+10mm Should have flexibility to restrict movement of the pushback and slider as per availability of aisle space. ARMREST:- Solid Wood Armrest. ARMREST CENTER CENTER DISTANCE:-560mm GROUTING:-4 nos of 75mm (for hard floor) FABRIC:-heavy duty 100% poyester dyed yarn with 3mm + 5mm foam backing/result tent. AISLE SIDE LAMP:- Provision for lights on sides for seats along the, i-laisles. Polypropelene Housing with 12mm watt lamp ROW NUMBERING:- Row i inumbering for
238(A) GROUND FLOOR
239Executive"sTable @ 1800Lx900Dx750HT Providing & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made ofMembrane finishwithsoftwater falledges &curvedpanel& DecoratedAnodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing
240(A) GROUND FLOOR
241(B) FIRST FLOOR
242Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H:- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between )as per drawing.
243(A) GROUND FLOOR
244(B) FIRST FLOOR
245Free Standing Table @ 1500Lx600Dx750HT ProvidingandfixingTableofSize1500x600x750mm.Top:madefrom25mm PrelaminatedParticleboard. Alledgesarecoveredby2mm.Thk.PVCedgebands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY(WITHOUTMOUSETRAY):- MetalPowderCoated-BlackColor,CPU TROLLEY:- MetalPowderCoated-BlackColor,3DRAWERPEDESTALUNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminatedparticle board,
246(A) GROUND FLOOR
247(B) FIRST FLOOR
248Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HTProviding & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT, CurvilinearTableTop@1500/1500Lx600/600D:-TOPtobemadeof25mmthick Prelaminated particle board with PVC edge band,GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :-Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
249(A) GROUND FLOOR
250(B) FIRST FLOOR
251Providing&ArrangemntofMIdBack,NormalSyncro Mechanism ,FixedArmrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery
252(A) GROUND FLOOR
253(B) FIRST FLOOR
254Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.
255(A) GROUND FLOOR
256(B) FIRST FLOOR
257Sofa Set 3+1+1 Providing&fixing SofaSet3+1+1BrownandCreamleatherDIMENSIONLength: 182.5 (cms)Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat
258(A) GROUND FLOOR
259(B) FIRST FLOOR
260Tea Table 900mm X 750mm X 450mm for m.s. ante chamber ProvidingAndFixingOfTeaTable900mmX750mmX450mmWith12mmThick ColourEitchedTemperedGlassWithBevelledDrawingMadeOut Of18mmThick WaterproofingPly.TheOuterLacesToBeFinishedWithHighQuality4MmThik Veneer Or 1 Mm Thik Mica Etc.
261(A) GROUND FLOOR
262(B) FIRST FLOOR
263ProvidingandfixingEuropeantypewhiteglazedearthenwarewaterclosetpanwith UPVCseatandlidwithchromiumplatedbrasshingesandrubberbuffersincluding UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps,20 mm dia.UPVCoverflow pipe ,mosquito proof couplings G.I. chain andpulley,with water Jetand fittingincludingcuttingand makinggood tothewallsand floors testingetc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use)
264(A) GROUND FLOOR
265(B) FIRST FLOOR
266ProvidingandfixingC.P.2WayBIBcockwithwallflange ofapproved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
267(A) GROUND FLOOR
268(B) FIRST FLOOR
269Providingandfixing Handshower(healthfaucet)with8mmdia.1mlongflexible tube having wall hook withapprovedmake including necessary sockets/ union nut etc. complete as directed by Engineer in charge.
270(A) GROUND FLOOR
271(B) FIRST FLOOR
272ProvidingandfixingC.P.BIBcockwithwallflangeofapprovedmakeincluding necessary sockets/ union nut etc. complete.
273(A) GROUND FLOOR
274(B) FIRST FLOOR
275Providingandfixing OvalTypeUnderCounterWashHandBasinof420x590x 195mmsize withpillar cock, C.P.Angular stop cock, long thread of approved makecontinental includingSSbottletrapof necessarypipeconnectionuptothe outsidefaceofthewall, havingTelephonicBlack/ColourGraniteof180 mm thick fixed on Black KadappaFramework,etc.Complete asdirectedby Engineerin charge.
276(A) GROUND FLOOR
277(B) FIRST FLOOR
278Providing and fixing wall hung white wash basin of size 550 x 400 x 195 mm with pillar cock having flow rate upto 6.0Litr/Minute, C.P .Angular stop cock long thread of Jaquar / Cera / Hindware / Perryware or equivalent make, including SS bottal trap of approved make etc complete as directed by Engineer incharge. (Make shall conform to manufacturer"s Green product and shall got approved from the Engineer In Charge.)
279(A) GROUND FLOOR
280(B) FIRST FLOOR
281Providing andfixing white glazed urinalofsize710x460x300mm with sensotronicconcealedtypeflushingvalveforurinalwithcompletekithavingfittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe withfittingandflushingarrangementincludingleadsoilpipe,leadtrap&soilpipe connection upto the outside face of wall etc complete.
282(A) GROUND FLOOR
283(B) FIRST FLOOR
284Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mm dia. nickel plated towel rod etc. complete.
285(A) GROUND FLOOR
286(B) FIRST FLOOR
287Providingandfixingmachinecutmirrorpolished18mm to20mm thicktelephone black granite / AmbaWhite /Cat barybrown/RBI red/ OceanBrowngranite stone partition with full moulding the edges etc.complete . Both side polish
288(A) GROUND FLOOR
289(B) FIRST FLOOR
290Providingand fixingon walls/ceiling/floor20 mmdia. CPVCpipewith necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipelineifnecessaryandconveyingandstackingthesameinPWDchowkyoras directed etc. complete.
291(A) GROUND FLOOR
292(B) FIRST FLOOR
293(C) SECOND FLOOR
294Providingandfixingonwalls/ceiling/floor25mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipelineifnecessaryandconveyingandstackingthesameinPWDchowkyoras directed etc. complete.
295(A) GROUND FLOOR
296(B) FIRST FLOOR
297(C) SECOND FLOOR
298Providingandfixingonwalls/ceiling/floor32mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipelineifnecessaryandconveyingandstackingthesameinPWDchowkyoras directed etc. complete.
299(A) GROUND FLOOR
300(B) FIRST FLOOR
301(C) SECOND FLOOR
302Providingandfixingonwalls/ceiling/floor40mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipelineifnecessaryandconveyingandstackingthesameinPWDchowkyoras directed etc. complete.
303(A) GROUND FLOOR
304(B) FIRST FLOOR
305(C) SECOND FLOOR
306(D) THIRD FLOOR
307Providingandfixingonwalls/ceiling/floor50mmdia.CPVCpipewithnecessary fittings, remaking good the demolished portion etc. complete.
308(A) GROUND FLOOR
309(B) FIRST FLOOR
310(C) SECOND FLOOR
311(D) THIRD FLOOR
312Providing and fixing on walls/ ceiling/ floors, 80 mm dia.heavy grade having embossed as ISIMark galvanised iron pipes weight of 10.15 Kilogram/meter with necessary fittings.and remaking good the demolished portion and applying primer of anti-corrosive oilpaint2coatsIncludingnecessaryscaffoldingandremovingexistingpipelineif necessaryandconveyingandstackingthesameinPWDchowkyorasdirectedetc. complete.
313(A) GROUND FLOOR
314Providing and fixing on walls/ ceiling/ floors, 100 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 14.74 Kilogram/meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
315(A) GROUND FLOOR
316Providing and fixing on walls/ceiling/floor 20 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
317(A) GROUND FLOOR
318(B) FIRST FLOOR
319(C) SECOND FLOOR
320Providing and fixing on walls/ ceiling/ floor 25 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
321(A) GROUND FLOOR
322(B) FIRST FLOOR
323(C) SECOND FLOOR
324Providing and fixing on walls/ ceiling/ floor 32 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete
325(A) GROUND FLOOR
326(B) FIRST FLOOR
327(C) SECOND FLOOR
328(D) THIRD FLOOR
329Providing and fixing on walls /ceiling/ floor 40 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
330(A) GROUND FLOOR
331(B) FIRST FLOOR
332(C) SECOND FLOOR
333(D) THIRD FLOOR
334Providing and fixing on walls/ ceiling/ floor 50 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
335(A) GROUND FLOOR
336(B) FIRST FLOOR
337(C) SECOND FLOOR
338Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
339(A) GROUND FLOOR
340(B) FIRST FLOOR
341(C) SECOND FLOOR
342Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
343(A) GROUND FLOOR
344(B) FIRST FLOOR
345(C) SECOND FLOOR
346Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
347(C) SECOND FLOOR
348Providing and fixing screw down for 40 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete.
349(C) SECOND FLOOR
350Providing and fixing screw down for 50 mm dia. wheeled stop tap of brass including necessary sockets/ union nut complete.
351(C) SECOND FLOOR
352Providingand fixing15 cmrigid PVC Nahani trap including PVC grating,bend,connectingpieceofUPVCpipeuptotheoutsidefaceofwall,makingthe good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)
353(A) GROUND FLOOR
354(B) FIRST FLOOR
355Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends, tees,reducers,clamps,etc.includingnecessaryexcavation,trenchfillingetc. complete.Includingremoving existing pipe line if necessary and conveying and stackingthesameinPWD chowky or as directed etc. complete.
356(A) GROUND FLOOR
357(B) FIRST FLOOR
358(C) SECOND FLOOR
359Providingandfixing75mmdiastabiliserpipe/P.V.C.soilvent/wastepipeand withnecessaryfixturesand fittingsuchasbends,tees,singlejunctions,slottedvent, clamps etc.complete
360(A) GROUND FLOOR
361(B) FIRST FLOOR
362(C) SECOND FLOOR
363Providingandfixing100mmdiastabiliserpipe/P.V.C.soilvent/wastepipeand withnecessaryfixturesand fittingsuchasbends,tees,singlejunctions,slottedvent, clamps etc.complete.
364(A) GROUND FLOOR
365(B) FIRST FLOOR
366(C) SECOND FLOOR
367Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and havingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992including proper rainwaterreceivingrecesswithP.V.C.plug,bend,necessaryfittings,suchas, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mmto40mmfromfaceofwallafixingwithclipsofapprovedqualityandOne Number ,filing the joint using rubber gasket withsolventcementandproperlyresting theshoeof pipes on C.C. ormasonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional2piecesocketclipsshallbegotapprovedfromengineerinchargeetc. complete.
368(A) GROUND FLOOR
369(B) FIRST FLOOR
370(C) SECOND FLOOR
371Providingand fixing40mm.diaBallcockmediumtypewithPVCfloatincluding sockets and necessary fittings and tested as per municipal requirements etc. complete.
372(A) GROUND FLOOR
373(C) SECOND FLOOR
374Providingandfixing100mmdiameterwatermeterwithnon-returnvalveincluding strainer,sockets/ unionnut andincluding water meter box making locking arrangementsandlock. [Without chamber].
375Providing andfixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8outsidethebuildingincludingcastirongratinginthesink,connectingglazed stoneware pipe,brickmasonrychamberwithcastironlidandcastirongrating forthe gully trap.
376Providing , laying and fixing ,jointingEco- drain 160 mm SN 4 Nu- Drain Upvc pipes or ofequivalentmake,manufacture asper EN13476orequivalent asper I.S.15328with fittings such abends,tees,coupler,etc,jointingwith rubberlubricantincluding necessary excavation, trench refilling with selective excavated materialetc. complete.
377Providing , laying and fixing ,jointingEco- drain 200 mm SN 4 Nu- Drain Upvc pipes or ofequivalentmake,manufacture asper EN13476orequivalent asper I.S.15328with fittings suchabends,teestees,coupleretc,jointingwithrubberlubricantincluding necessary excavation, trench refilling with selective excavated materialetc. complete.
378Providing , Laying and fixing, jointing Eco Drain 250 mm SN-04 Nu-Drain Upvc pipe or ofequivalentmake,manufactureasperEN13476orequivalentasperI.S.15328 & 16098withfittingssuchabends,tees,coupler,etc.jointingwithrubberlubricant, includingnecessaryexcavation,trenchrefillingwithselectiveexcavatedmaterialetc. complete.
379Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 450mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
380Providingand constructingBrick Masonry Inspection Chamber 60cm x 45cm x 90cm including1:4:8 cementconcretefoundation 1:2:4 cementconcretechannels halfroundG.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete.
381Providingand constructingBrick Masonry Inspection Chamber 90cm x 45cm x 90cm including1:4:8 cementconcretefoundation 1:2:4 cementconcretechannels half roundG.S.W.pipes,BrickMasonry,plasteringfrominsideandC.I.lidcoverof 75Kilogramwith lid and frame fixed in cement concrete.
382RWH - Recharge PitProviding andconstructing rechargepitof2.0m deepand1.0m diaofpre-castRCC ringswith 6.5" dia x 25mdeep borewell atthefloorof rechargepit including installation ofcombinationofsolid/perforatedPVCcasingpipewrappedaroundwith netlonmeshincluding300mm thick sidefilling around outside of RCC rings (annular space) with 40mmsize boulders includingfillingofrechargepitup to 0.5mdepth with 25-75mmclean washedgravelsfrom bottom upfollowedby 0.5m depthof10-25mmofcleanwashedstonesfollowedby0.5mofwashedriverfine aggregate(naturalsand/crushedsandVSIgradefinelywashedetc.) including netlon meshbetweeneachgravel/fineaggregate(naturalsand/crushedsand VSI grade finely washedetc.)medialayerincludingcoveringwithRCCslab,manholeframe&cover, PVCrungs,PVCend-caps,fittingsetc.includingarrangementforinlet&outletpipe excavation &backfillingasshown inthedrawing.Therateshallbeinclusiveofall labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All materialshould beofapproved make.Allworkscompleteasper the drawing,technical specification and direction of the Engineer in charge.
383Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and capincluding necessary (including excavation and laying)
384Providingandlayingintrenches100mmdia.mediumgradehavingembossedasISI Mark galvanised iron pipes ?of 12.43 Kilogram/meter necessary fitting remaking goodthedemolishedportionwithfillingtrenchesandwithprimerofanti- corrosiveoilpaint,2coatsIncludingremovingexistingpipelineifnecessary and conveying andstacking the same in PWD chowky or as directed etc. complete.
385DismantlingflatwoodenorA.C.Sheetceilingwithframeworkincludingstacking the materials as directed with all leads, lifts etc. complete.
386Removing iron pipe raling having wooden R.C.C. or C.C. or iron post and stackingthe materials as directed etc. complete.
387Removing cloth ceiling including frame work and stacking the materials as ditected with all leads, lifts etc. complete
388Dismantlingbrickmasonryinlimeorcementmortarandstackingthematerilsas directed with all leads, lifts etc.
389Removingdoorsandwindowswithframesandstackingthematerialsasdirected withall leads, lifts etc. complete.
390Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete.
391Removingrichmixcementconcreteincludingstackingthespoilsasdirectedwithall leads, lifts etc, complete.
392Removingcementtiles,ormarbleorpolished shahabadfloorordadowithoutbed concrete including stacking the materials as directed with all leads, lifts etc. complete
393Removinglimeorleancementconcreteincludingstackingthespoilsasdirected withall leads, lifts etc, complete.
394ROYALTY FOR SAND
395ROYALTY FOR 80MM SOLING METAL
396ROYALTY FOR MURUM
397CEMENT TEST : Standard Consistancy,Fineness, Specific Gravity,Setting Time ( Initial & Final ), CompressiveStrength, Soundness.
398CONCRETE TEST : Concrete Mix Design
399CONCRETE TEST : Compressive Strength OF C.C. Cube (Set of 3 cubes).
400STEEL TEST : (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
401STEEL TEST : (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)Above 16 mm (Set of 3 Bars)
402Fine Aggregate :Finness Modulus(sieve analyais)silt content and clay content
403Fine Aggregate : Chloride& Sulphate Content.
404Fine Aggregate : Silt Factor.
405Coarse Aggregate : Water Absorption, Specific Gravity,Impact Value, Crushing Value.
406Coarse Aggregate : Sieve Analysis.
407Coarse Aggregate : Abrasion Value.
408Coarse Aggregate : Flakiness Index & Elongation Index.
409Coarse Aggregate : Stripping Value. (for Bituminous Work)
410Coarse Aggregate : Soundness.
411CONCRETE PAVING BLOCKS : Compressive Strength , Water Absorption,(Set of 8 Blocks)
412HB METAL : Crushing Value/Compressive Strength,Water Absorption & Specific Gravity
413MURUM : Liquid limit & plastic Limit.
414VETRIFIED TILES : Water Absorption, Modulus of Rupture (Set of 6 Tiles)
415BRICKS : Compressive Strength
416BRICKS : Water Absorption
417Water : PH Value, Sulphate & Chloride Content
418Teak wood : Density, Moisture Content.
419Flush door : Knife Test, Adhesion Test, End Immersion Test
420GI Pipe : Weight per running meter,Diameter of pipe & wall thickness of pipe,
421P.V.C. PIPES (NONPLASTISIZED) : Weight per running meter,Diameter of pipe & wall thickness of pipe
422NON -DESTRUCTIVE TEST : Rebound Hammer Test.
423CONCRETE : Flexural strength of Beam
424Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
425Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
426Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
427SSupplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
428Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
429Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCCwork/false ceiling/false flooring as per specification No. WG-MA/CC.
430Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in providedconduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
431Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
432Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
433Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/Bus bars or any other places.as per specification No: WG-MA/BW
434Supplying & erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking /inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW(LDB Circuit)
435Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places. as per specification No: WG-MA/BW(LDB Circuit earth)
436Supplying & erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole /Bus bars or any other places as per specification No: WG-MA/BW(PDB & Main LDB Circuit) (Rs 103 x 2 = 206)
437Supplying & erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/ trunking/ inside pole/ Bus bars or any other places as per specification No: WG-MA/BW (PDB Circuit earth) (Rs 103 /2 = 51.50)
438Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
439Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
440Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
441Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
442Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
443Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
444Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
4451-w-Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
4462-w-Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
447Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/ CW
448Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/SW.( EXHAUST FAN)
449Wiring for plug on board with Switch socket surface/ concealed type, copper wiring and earthing and with modular accessories as per specification No: WP W/CW
450Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit/ casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switc
451Point wiring for Ceiling Fan hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit/ casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switc
452Secondary point wiring for additional light/ bell point, concealed type in min 20 mm FRLS grade PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification No: WG-PW/CW
453Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
454Supplying and erecting integrated LED Highbay Fitting 100W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 15000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification No FG-ODF/FLS2
455Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
456Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation.
457Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
458Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remotecontrol/ compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF (without remote) (3811-10%)
459Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
460Supplying and erecting LED square / circular Max. 14 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty
461Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clipscomplete with 3 years warranty
462Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
463Supplying and erecting LED Panel Light(600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
464Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab
465Supplying, erecting, testing and commissioning of 6kVA capacity online pure sine wave with backup time of .1/2.hrs. (30 min) PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS(for Camera NVR, LAN Rack & EPABX supply)
466Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
467Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
468Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
469Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses /pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
470Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
471Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
472Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP.
473Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.(From Transformer LT Panel to Main MCCB Panel Cable- Panel Room)
474Supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof ABS plastic body, high grade SS inner tank & 3kW heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermal cut-out, function valve) complete with 6.5 bar pressure withstanding capacity 230/250V, 50Hz, A.C. supply with inlet and outlet, with 3 core PVC flexible copper wire leads duly tested and marking sr. no. and date of erection complete.
475Providing fiber reinforced PVC flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos.) complete.
476Supplying 16 amp. 3 pin plug Top bakelite type of 230 V. A.C. supply
477Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
478Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
479Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
480Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
481Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
482Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
483Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
484Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
485Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
486Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
487Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/ MCCB (18563)
488Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/ RCBO
489Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 6 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (ExcludingMCCBs)
490Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 8 ways Four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
491Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 12 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW SWR/MCCBPB. (Excluding MCCBs)
492Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 400A, 4 ways four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no. SW-SWR/MCCBPB. (Excluding MCCBs)
493Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 6 way outgoing or 400A incoming and 4 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
494Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
495Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 12 way outgoing or 400A incoming and 6/8 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB.
496Supplying and erecting terminal spreaders suitable for 4 pole, up to 100A MCCB (Set of 8)
497Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to400A MCCB (Set of 8)
498Supplying and erecting terminal spreaders suitable for 4 pole, above 400A up to 630A MCCB (Set of 8)
499Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
500Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB.
501Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.(+ 200kg for matminton lighting)
502Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
503Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete.
504Supplying, erecting, testing and commissioning of diesel generating set with alternator of 62.5 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 11.3 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 150 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
505Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 50 kVA up to 62.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF...(10% less)
506Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (50 mtr- 2 Run)
507Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
508Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
509Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. (25x3 GI Strip - 30 Mtr x 0.59 Kg/Mtr = 17.7)
510Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
511Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
512Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
513Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
514Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
515Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specificationNo. WG-MA/CC.
516Supplying and fixing POE adaptor to provide DC supply to ethernet devices as per specification No. WG-NAS/PEA
517Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
518Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
519Supplying and erecting 25m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
520Supplying erecting testing and commissioning of 2 MP motirised , verifocal, IP Dome Camera with built in microphone with having following features:(1) maximum 2M (1920 x 1080 ) resolution, (2) Min. Illumination : Color 0.095 LUX (30 IRE) , B/W : 0 Lus (IR LED On), (3) 2.8 - 12mm (4.3x) varifocal lens, (4) Field of view : H : 103.80 - 32.40/ / V: 53.70 - 18.40/ D : 121.90- 37.10 (5) 120 dB WDR (6) Max. 30 fps @ 2 M all resolusions (H.265/ H.264), (7) H.165, H.264 codec supported, (8) Intelligent analytic like Motion detection with metadata, tampering, defocus detection, (9) 128 GB micro SD/ SDHC/ SDXC memory slot, PoE/ 12V DC,(10) IR viewable length 20m. (11) Motion detection min 4 zones. (12) Multiple streaming upto 3 profiles, (13) Model specific UL,CE& FCC certification. Detection min 4 zones (14) multiple streaming min upto 3 profile (15 LDC support (16) Model specification and UL , CE & FCC certificationI) I) Video Resolution; Sub Stream 2MP (1920+1080) max; 30fps, Third Stream: D1 (720x576) max;30fps 2)Frame Rate;- Main stream 4MP (2592x1520), 20fps, 4MP (2560x1440) ; max; 25fps, 3MP (2048x1520); max 30fps sub stream 2MP (1920x1080) (Reference taken from- Estimet No-1356/BND/2021-22, TS Dt-25th Jan 2022 Sanction No. 196)
521Supplying erecting testing and commissioning of 2 MP motirised , verifocal, IP Bullet Camera with external microphone with having following features:(1) maximum 2M (1920x1080) resolution, (2) Min. Illumination: Color 0.095 LUX(30IRE), B/W: 0 Lus (IR LED On), (3)2.8- 12mm(4.3x) varifocal lens, (4) Field of view: H: 103.80- 32.40/ V: 53.70- 18.40/D : 121.90- 37.10 (5) 120dB WDR (6) Max. 30 fps @ 2 M all resolusions (H.265/ H.264), (7) H.165, H.264 codec supported, (8) Intelligent analytic like Motion detection with metadata, tampering, defocus detection, (9) 128 GB micro SD/ SDHC/ SDXC memory slot, PoE/ 12V DC,(10) IR viewable length 30m. IP-66, IK10 (11) Motion detection min 4 zones. (12) Multiple streaming upto 3 profiles, (13) Hallway, view support, (14) LDC Support (15) Model specific UL, CE & FCC Certification I) Video Resolution; Sub Stream 2MP (1920+1080) max; 30fps, Third Stream: D1 (720x576) max;30fps 2) Frame Rate;- Main stream 4MP (2592x1520), 20fps, 4MP (2560x1440) ; max; 25fps, 3MP (2048x1520); max 30fps sub stream 2MP (1920x1080) (-Reference taken from 100 Beded Akot Hospital (NHM), Akot, Sanction date-6-12-22, TS No- 672 (Letter No 2385)
522Supplying erecting testing and commissioning of 32 channel network video recorder (NVR) with 8. HHD slots for 48 Tb storage support having following specification : Dual core embeded processor with 8 HHD slots supporting 48 TB for internal recording and external ISCSI storage upto 384 TB, Embedded Linux, 32 Channel with 1080p Realtime Live View upto 12 Mega pixel resolution preview & playback ,256 Mbps Recording Bandwidth & 32 Mbps playback bandwith atleast playback of 16 channels simultaneously, Supporting TCP/IP,UDP/IP, RTP(UDP), RTP (TCP), RTSP, NTP, HTTP, DHCP (Server,Client), PPPoE, SMTP, ICMP, IGMP, ARP, DNS, DDNS, uPnP, HTTPS, SNMP, ONVIF (Profiles), SUNAPI (Server, Client) Protocals.(-Reference taken from 100 Beded Akot Hospital (NHM), Akot, Sanction date-6-12-22, TS No- 672 (Letter No 2385)
523Supplying erecting testing and commissioning of 8TB cpacity internal SATA HDD having following specification General 7200.14, Capacity 8TB, Form factor 3.5"", interface option SATA 6Gb/s, Performance , Transfer rate Max Ext (MB/s)600, Sustained data rate OD210MB/s, Average latency (ms) 4.16, Power management , Idiling Typicaloperating (W) 7.5, Similar to Seagate make SATA 8TB (ST4000DM000)with 2yrs manu warrenty. -Reference taken from 100 Beded Akot Hospital (NHM), Akot, Sanction date-6-12-22, TS No- 672 (Letter No 2385)
524Supplying erecting testing and commissioning 108 cm (43") Full HD slim LED television having Display 1920x1080 resolution similar to 2 x HDMI, 2 x USB Port 1 Year Samsung India Warranty 95 W Power Consumption Similar to Samsung Joy Plus UA43J5100AR43. (-Reference taken from 100 Beded Akot Hospital (NHM), Akot, Sanction date-6-12-22, TS No- 672 (Letter No 2385)
525Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
526Supplying and erecting minimum Three & above star rated submersible pump set of 3.75KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 88 to 26 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP
527Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP (1 running & 1 standby)
528Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assemblycomplete.
529Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
530Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
531Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
532Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete.
533Supplying and erecting 50 mm dia. gun metal foot valve at position with necessary materials complete.
534Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
535Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete.
536Supplying & erecting four pole ON LOAD change over switch, 415V, 40A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. (for openwll pump, incase felure)
537Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC
538Supply, Installation, Testing, and Commissioning ofIndoorLED Screen 20 Feet (W) x 11 feet (H)with the following specifications:-Dimensions (w x h) (mm) -320 x 160mmPixel pitch - 2.5mm IndoorLED Configuration & Make- SMD 2121Resolution (w x h) - 128 x 64Pixel Density -160000 dots/m, Pixel Configuration- (1R,1G, 1B)Brightness Control - 256 levels.Viewing Angle - 140/120 DegreeMinimum Viewing Distance - >2.5m Brightness Control - 256 LevelsRefresh Frequency - 1920/3840HzDriving Mode - constant current drivingScan method - 1/32 Scanning, Input power frequency -50 or60HzInput Voltage - 140 ~ 260 VoltPower Consumption Maximum - <488 W/mPower Consumption Average - 163 W/mBlind spot rate - <1/10000 hoursCabinet Services method - Front Rear ServiceLifetime at 50% brightness - 100000 hoursInternational Protection - IP 43Operation Temperature --20~ + 60 C+ 10%MTBF - >10,000hoursWorking humidity - 10%-90%RHSignal input format - Composite, S-Video, VGA, DVI, YPbPr, HDMI, SDI/USB
539ALL-In-One Controller - Support for 5 inputs: DVI x 1, HDMI x 1, VGA x 1, USB x 1, CVBS x 1 Dual-Ethernet output, 1.3 million pixel loading capacity, a maximum width of 3840 Support for Smart Configuration Adjust layer position, layer size, and screen capture Support for full-screen scaling, with total flexibility. Support for fade-in and fade-out switching effects Features operational status lights Support for 6 users presets
540Supply, Installation, Testing & Commissioning of CE Certified Motorised Stage & FOH Light bar Suitable Length 8 - 14 Mtrs, Suitable Capacity 3 Phase AC Motor with DC Brake. & Gear box with black epoxy polyester powder coated with following specifications - • 40NB, 48mm OD dual barrel dual construction arrangement with 75x6mm MS Flat in every 2 m and with 40x75 Cable trunking with lid. • With Frill Attachment for stage area lightbar. • MS fabricated cable retractor made up of CRCA MS Sheet 20SWG 1300mm each length with hinge rod • Specially designed compact 80:1 Worm reduction gear box, B5 Flange. • Double Cam type Upper and lower limit controller 5mm, 6x19 GI wire rope preformed for lifting the Light bar • Pile winding type winch with MS circular Plates for rope winding • Safe Working Load 180 kg
541Supply, Installation, Testing & Commissioning of Front Split HorizontalCurtain:- The complete automatically motorized Stage curtain system with additional modified Gearbox fitted with sealed bearings self-lubricating centre split overlapped curtains both sides opening fully automatic Stage Curtain fixing steel rails track made out of 450 GSM made out of, double gathering , Molfin, Mokel or Amoshi Fabric Curtain cloth drapery horizontal sliding arrangement complete with fixing rails, brackets and motorized operation complete with runners, master runners, pullies, 3mm steel wire rope, 1 HP Motor (Crompton or Godrej) 2 Nos Air Breaker Contractors (L&T/SIEMENS), 2nos. Micro Switches for auto stop, 3 nos push buttons for forward. All rollers are sliding with roller clamp, The curtain should be half of full width operated from control panel with control switches. Provision is for fully automatic operation only. Height 20ft , Length60ft FABRIC SPECIFICATION :450 GSM, MOLFIN, Amoshi & MOKEL Fabric Proposed:Amoshi 450 GSM
542Supply, Installation, Testing & Commissioning of Stage Frills Curtain:- STAGE FRILLS: made out of, 450 GSM double gathering glazed , Molfin, MokelFabric; to be installed above the stage on 32mm dia MS pipe adjustable at position according to stage positioning plan; Cloth material of desired shade with Stitching.FABRIC SPECIFICATION : 450 GSM AMOSHI
543Supply, installation, testing & Commissioning of highpower install grade 15" Three way loudspeaker system with a rotatable horn with extended frequency range with mounting points for OEM hardware/ bracket. Frequency 38Hz to 20KHz (-10 dB) 600W continuous Coverage 60 x 40Degree Sensitivity 115dB Maximum SPL 139 dB Nominal Impedance 8 ohm LF Driver 15"HF compression driver with 3" voice coilBiamp/ Passive Switchable.
544Supply, installation, testing & Commissioning of highpower install grade 15" Three way loudspeaker system with a rotatable horn with extended frequency range with mounting points for OEM hardware/ bracket. Frequency 38Hz to 20KHz (-10 dB) 600W continuous Coverage 90 x 50Degree Sensitivity 115dB Maximum SPL 139 dB Nominal Impedance 8 ohm LF Driver 15" HF compression driver with 3" voice coil Biamp/ Passive Switchable.
545Supply, Installation, Testing & Commissioning of mounting bracket. Supply, installation, testing & Commissioning of highpower install gradeDual 18" low frequency loudspeaker systemwith extended frequency range with mounting points for OEM hardware/ bracket. Frequency 28Hz to 1KHz (-10 dB) 1600W continuousSensitivity 102dB Maximum SPL 136 dB Nominal Impedance 4 ohm LF Driver 18"LFdriver with 4" voice coil
546Supply, installation, testing & Commissioning of highpower install gradeDual 18" low frequency loudspeaker systemwith extended frequency range with mounting points for OEM hardware/ bracket. Frequency 28Hz to 1KHz (-10 dB) 1600W continuousSensitivity 102dB Maximum SPL 136 dB Nominal Impedance 4 ohm LF Driver 18"LFdriver with 4" voice coil
547Supply, installation, testing & Commissioning of 18inch - 21inch ormore High Power Subwoofer; Frequency Range 28Hz–1kHz or better; Frequency Response 35Hz–1kHz or better; Transducer Power : 4800W peak; Max SPL 135dB peak or better; Sensitivity 98dB or better; Capable to support Suspension Attachment; Powder coated 14 gauge perforated steel Grille with acoustically transparent black foam backing; Impedance: 8 ohms; etc. The loudspeaker should have integrated mounting bracket for permanent installation.
548Supply, Installation, Testing & Commissioning of 12" or better Two-Way Self-Powered Stage Monitor Loudspeaker System; should support Power rating 2000W(pk) ormore; Frequency Range 51Hz – 20kHz orbetter; Max. SPL 132dB or more; Coverage Pattern 90° x 50° or better; Crossover Frequency: 2050Hz; User selectable Optimized presets for Main or Monitor position; 100V - 240V ~ 50/60 Hz Operation; Should support audio connectivity with minium 2 x XLR balanced Combo jacks; 1 x 3.5mm aux input; 2 x XLR-M loop-through; 1 x XLR-M mix out; etc.
549(A)Supply, Installation, Testing & Commissioning of Multichannel Digital Network Based Power Amplifier with Power output 4 x 1250W - 1300W @ 4 Ohms / 8 Ohms; Should support 70Vrms and 100Vrms output on all output channels; THD 0.35% orbetter; Cooling Continuously variable speed forced air; Voltage Gain 34dB ormore; Digital bus compatibility up to 8 or more audio channel; bridgeable channels even in 100Vrms mode to operate with 200Vrms output; 2digital audio bus RJ 45 port; 1 Ethernet R 45 port for monitoring and configuration; Should have DSP features like Limiters , Input/output EQ , Delay ,Matrix Mixer ,Speaker Line Monitoring; Damping Factor (20Hz to 100Hz) : >1500 ormore; etc.
550(B) Supply, Installation, Testing & Commissioning of Multichannel Digital Network Based Power Amplifier with Power output 4 x 600W - 650W @ 4 Ohms / 8 Ohms; Should support 70Vrms and 100Vrms output on all Eight channels; THD 0.35% orbetter; Cooling Continuously variable speed forced air; Voltage Gain 34dB ormore; Digital bus compatibility up to 8 or more audio channel; bridgeable channels even in 100Vrms mode to operate with 200Vrms output; 2digital audio bus RJ 45 port; 1 Ethernet R 45 port for monitoring and configuration; Should have DSP features like Limiters, Input/output EQ, Delay, Matrix Mixer, Speaker Line Monitoring; Damping Factor (20 Hz to 100 Hz) : >1000; etc.
551Supply, Installation, Testing & Commissioning of Four-channel Power Amplifier, each channel should support minium 4000W at 4 Ohms; True Ethernet backbone – fast, reliable and scalable; Color LCD provides users with diagnostics and presets for easy setup; Sweep Load Monitoring; one USB port; Damping Factor :(10Hz to 100Hz) >5000 ormore; Signal to Noise Ratio ( 20Hz to 20kHz, A Weighted) :> -108dB or better; THD (full rated power, 20Hz to 20kHz): <0.35%; Intermodulation Distortion (from 9dB down to -40dB): 0.06%; Frequency Response (20Hz to 20kHz at 1W into 4/8O) :+/-0.25dB; Crosstalk (below rated power 20Hz to 1kHz): >80dB; etc.
552(A)Supply, Installation, Testing & Commissioning of Digital Mixing Console with Digital Card for routing digital audio signal over a network cable; Should support minimum 32 mono mic inputs and 4 analog line inputs; 4 Stereo Effects engines; 4 Fx Busses & 8 Matrix Busses; Delay on inputs and outputs, 16 auxilary outputs, 5-inch display. Should support pre-sets store and recall.
553(B)Snakecable &Stage Box
554Supply, Installation, Testing & Commissioning of 12 x 8 Networked Digital Signal Processor with 12 inputs and 8 outputs or more; 12 ormore Control Inputs and 6 or more Logic Outputs for GPIO Integration; 48V phantom power on all analog inputs; THD: <0.01% 20Hz to 20KHz; Crosstalk: <-75dB orbetter; Open architecture software configurable; logic processing power; 2 digital audio bus RJ45 Port; 1Ethernet RJ45 port for Monitoring and configuration; Capable to handle +5V unloaded logic output voltage; Should have speech sense engine; Capable to control 3rd party devices with TCP IP and RS232; Should have 1nos of RS 232 port for integration with control System; Should have Bi-Directional Locate Functionality; Should have 48 or more digital audio Channel Bus; Should have monitoring LED for COM, STAT, ERR and PWR; etc. Approved Make: BSS / bi-amp / symetix
555Supply, Installation, Testing & Commissioning of Gooseneck Microphone -: Supply  of Condenser Cardioid Gooseneck Microphone with Condenser, back electret microphone element, with a frequency response of 100Hz-15kHz, Cardioid polar pattern, the sensitivity of 4.5mV/Pa, rated impedance of 200 ohm and dynamic range;102dB.
556Supply, Installation, Testing & Commissioning of Professional wired vocal dynamic microphone with On/Off Switch and should support Polar Pattern supercardioid orbetter; Audio Frequency bandwidth 70 to 20000Hz ormore; Sensitivity 2.6 mV/Pa or better; Electrical Impedance : 600 Ohms or better; Recommended Load Impedance : 2000 Ohms or more; Connector Type : 3-pin XLR Male (Balanced);Metal Body; etc.
557Supply, Installation, Testing & Commissioning of Wired Dynamic Instrument Microphone with Cardioid orbetter Dynamic Instrument Microphone; Audio frequency bandwidth 40-20000Hz ormore; Sensitivity 2.5 mV/Pa or more; Max. SPL 47dB ormore; etc.
558Supply, Installation, Testing & Commissioning of Wireless Handheld Microphone System, Wireless Microphone system with MHZ carrier frequency band, Up to 16 pre-programmed frequencies within the same frequency band, Audio bandwidth 35 - 20,000 Hz, THD at 1 kHz: <0.3%(Receiver) , Signal-to-noise: 120 dB(A)( Receiver), Wideband FM Modulation, Up to 48 Simultaneous channels , Upto 14 hours operation with one single AA battery or better, Pilot Tone, transmission to know the transmitter battery status, Receiver should have microphone level and line level output, Transmitter should have display to show the battery and LED to show the Muted /Unmuted status, Sensitivity 6.3 dB V / -100 dBm, Should have Microprocessor-controlled diversity, T.H.D.: 0.7 % (Transmitter), Infrared programmable, RF output power: 10 or 50 mW; etc.
559(A)Supply, Installation, Testing & Commissioning of Wireless Lavalier Microphone System, Wireless Microphone system with MHZ carrier frequency band, Up to 16 pre-programmed frequencies within the same frequency band, Audio bandwidth 35 - 20,000 Hz, THD at 1 kHz: <0.3%(Receiver), Signal-to-noise: 120 dB(A)( Receiver), Wideband FM Modulation; Up to 48 Simultaneous channels, Upto 14 hours operation with one single AA battery or better, Pilot Tone transmission to know the transmitter battery status, Receivershould have microphone level and line level output, Transmitter should have display to show the battery and LED to show the Muted /Unmuted status, Sensitivity 6.3 dB V / -100 dBm, Should have Microprocessor-controlled diversity, T.H.D. 0.7 % (Transmitter), Infrared programmable, RF output power: 10 or 50 mW; etc.
560(B) Supplying and fixing 27 U floor mount rack (Dimension-DxWxH - 800X600x1398 mm) as per specification No. WG-NAS/RAK
561Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
562Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
563Supplying, installation, testing and commissioning ofmain fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacityfor manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation onwith IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/SSC/EP
564Supplying, installation, testing and commissioning of jockey fire pump (JP)suitable for water discharge of 180 to 240 LPM at 110 to 90 m head driven by electric motor415 volts, 3 phase 50 Hz, AC supply of 11 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/JP
565Supplying, installation, testing and commissioning ofmain fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speedsuitable for manual/automatic operation and consisting of following : (a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
566Supplying, installation, testing and commissioning ofbooster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operationwith IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevellingcomplete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
567Supplying, erecting, testing & commissioning offire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessorieswith following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specificationsthe capacity of electric motor driven pump are as followsa. Main fire pump(MFP) having capacity of 22kW 1no (1 working)b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears:1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating.2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handlewith HRC fuses of suitable rating. ------------------------For Detailed wording of Item refer tender Booklete
568for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....
569Supplying and erectingG.I. pipe‘C’ class ERW25 mm dia with necessary fittings complete asper specification no. FF-PP
570Supplying and erectingG.I. pipe‘C’ class ERW75/80 mm dia with necessary fittings complete asper specification no. FF-PP
571Supplying and erectingG.I. pipe‘C’ class ERW100 mm dia with necessary fittings complete asper specification no. FF-PP
572Supplying and erectingG.I. pipe‘C’ class ERW150 mm dia with necessary fittings complete asper specification no. FF-PP
573Providing coating of bitumen paint &4mm thick wrapping for underground 150 mm ring main of fire fighting system.
574Supplying anderecting100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SSscreen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS
575Supplying anderecting150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SSscreen,end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS
576Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV
577Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV
578Supplying and erecting 100 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV
579Supplying and erecting 150 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV
580Supplying and erecting20 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV
581Supplying and erecting25 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV
582Supplying anderectingstainless steel single outlethydrantvalve fitted with necessary accessories complete asper specification no. FF-VL/HV
583Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose)along with necessary accessories complete asper specification no. FF-FFA/HV
584Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m inlength, fitted with necessary accessories complete asper specification no. FF-FFA/RRL
585Supplying and erecting 19 mm dia high pressurerubber hose pipecomplete asper specification no. FF-FFA/RHP
586Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specifications no. FF-FFA/NZ
587Supplying and erecting 19 mm dia gun metal chrome plated nozzle complete asper specification no. FF-FFA/NZ
588Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete asper specification no. FF-FA/FBC
589Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete asper specification no. FF-FA/FMC
590Supplying and erecting300 mm dia 1.5min heightair vessel / tankfabricated from min 5mm thick M.S. sheet complete asper specification no. FF-FFA/ACT
591Supplying anderecting20/25mm dia gun metal air release cock, with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete asper specification no. FF-FFA/ARV
592Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete asper specification no. FF-FFA/PG
593Supplying and erecting12/15 mm dia pressureswitchwith provided isolationvalve,G.I. nipple, elbow, etc complete asper specification no. FF-FFA/PS
594Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP
595Supplying and erecting M.S./CRCA cabinet forhousingFireBrigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet andangleiron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") andlocking arrangement with necessaryfixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
596Supplying, installing, testingand commissioning FR, XLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU
597Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 1 loop capacity and capable of supporting upto 250 devices and detectorsper loop,with on-board LCD display with min 16 lines of text,operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipmentvia a MODBUS/ OPC/ L-ONinterface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/UL864 (10th edition) with 3 years replacement warranty FF-AFAS/CP.
598Supplying, installing, testing and commissioning ofrepeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than175 x 275 x 65 mm conforming to EN 54 or UL approvedwith 3 years equipment replacement warranty FF-AFAS/RP
599Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approvedwith 3 years equipment replacement warrantyFF-AFAS/SD .
600Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area"s etc. with 3 years equipment replacement warrantyIS : 2175 - 1988 reaffirmed 2000,IS 15908:2021 standards FF-AFAS/SD.
601Supplying, installing, testing and commissioning of addressablemanual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass"massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listedwith 3 years equipment replacement warrantyFF-AFAS/MCP.
602Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warrantyconforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays,EN 54 or UL Listed FF-AFAS/CRM
603Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listedwith 3 years equipment replacement warranty conforming toIS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
604Supplying, installing, testing and commissioning of addressable fire isolator module complete as required.EN 54 /FM or UL Listedwith 3 years equipment replacement warranty conforming toIS 5051Part 2 (Sec 1 to 3) : 1982 Reed relaysFF-AFAS/ISM
605Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage rangeEN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
606Supplying, erecting testingand commissioningbeam smoke detector four wiresingle ended reflected type with 8 " receiver having digital display for easy alignment, adjustable sensitivity & heater kit for transmitter/receiver and reflector with necessary connections on suitable back box. The protection range of beam detector is 5 to 70 m.
607Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
608Supply & Erecting of fire exit sinages with Battery backup 24hrs auto glow sinages
609Supplying & erecting ABCfire extinguisher of 6 kg. capacityconform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
610Supplying & erecting fire bucket 9 ltr capacity 04 Nos with M.S Stand
611Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
612Supplying, installation, testing and commissioning of booster fire pump[BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of7.5 kW or of suitable kW capacityfor manual/automatic operation and consisting of following : (a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation onwith IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
613Panel for 5.5/ 7.5 kW centrifugal type booster pump 1no(1working) , add Rs…....
614Supplying and erectingG.I. pipe‘C’ class ERW75/80 mm dia with necessary fittings complete asper specification no. FF-PP
615Supplying and erectingG.I. pipe‘C’ class ERW100 mm dia with necessary fittings complete asper specification no. FF-PP
616Supplying anderecting100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SSscreen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) forpositive suction complete asper specification no. FF-VL/ELS
617Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, asper specification no. FF-VL/BFV
618Supplying and erecting 100 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV
619Supplying and erecting20 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV
620Supplying and erecting25 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV
621Supplying anderectingstainless steel single outlethydrantvalve fitted with necessary accessories complete asper specification no. FF-VL/HV
622Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose)along with necessary accessories complete asper specification no. FF-FFA/HV
623Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m inlength, fitted with necessary accessories complete asper specification no. FF-FFA/RRL
624Supplying and erecting 19 mm dia high pressurerubber hose pipecomplete asper specification no. FF-FFA/RHP
625Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specifications no. FF-FFA/NZ
626Supplying and erecting 19 mm dia gun metal chrome plated nozzle complete asper specification no. FF-FFA/NZ
627Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete asper specification no. FF-FA/FBC
628Supplying anderecting20/25mm dia gun metal air release cock, with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete asper specification no. FF-FFA/ARV
629Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete asper specification no. FF-FFA/PG
630Supplying and erecting12/15 mm dia pressureswitchwith provided isolationvalve,G.I. nipple, elbow, etc complete asper specification no. FF-FFA/PS
631Supplying and erecting brass orifice plate having 6 mm. thickness, 160 mm outer dia with required diameter of inner hole at every double outlet hydrant valve as per specification no. FF-FFA/OP
632Supplying and erecting M.S./CRCA cabinet forhousingFireBrigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet andangleiron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8" x 6") andlocking arrangement with necessaryfixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
633Supplying, erecting testing and commissioning manual call point (Pill box) with break glass, push button (resettable type) in metal enclosure complete asper specification no. FF-FAAS/MCP
634Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete asper specification no. FF-FAAS/HTR
635Supplying, installing, testingand commissioning FR, XLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU
636Supplying, installing, testingand commissioning of 2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2CharacterLCDDisplay, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC,0 - 49 Deg C,93 ± 2 Percentage RH (non- condensing) at 32± 2 Deg C complete asper specification no. FF-FAAS/FACP
637Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
638Supply & Erecting of fire exit sinages with Battery backup 24hrs auto glow sinages
639Supplying & erecting ABCfire extinguisher of 6 kg. capacityconform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
640Supplying & erecting fire bucket 9 ltr capacity 04 Nos with M.S Stand
641Air Cooled VRF Outdoor Unit Supplying, erecting, testing and commissioning of below capacities,VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation incooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete. Note:- 1) Rate of duly coated MS fabrictaed stand (C-channel / Angle) with double coat Zinc cromate and paint shall be inclusive in quoted rate. 2) Rate of Lifting, Shifting, proper positioning of ODU"s on stand at Terrace shall be inclusive in quoted rate.
64228 HP
64320 HP
64418 HP
645Indoor Units:Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 8.0TR (3200 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete.
646Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
647Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
648Supply, installation, testing and commissioning of VRF/VRV based ceilingsuspended 4 Way cassette room/indoor unit (IDU-compact/standard size)of nominal cooling capacity 1.0TR ( 441 cfm ) to 1.3TR (512 cfm ) havingEER as per BEE standards and specifications, suitable as per site requirementwith swing louvers and adjustable blades from sides. IDU with drainagearrangements, fan, refrigerant liquid and refrigerant piping, cordless remotecontrol, and fresh air port etc. IDU shall have anti corrosive coating suitable forcoastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supplycomplete. The unit consisting with any additional refrigerant and oil charge as perrequirement during installation.
649Supplying, erecting, testing and commissioning centralised programmable remote contol panel (HMI) touch manager controls minimum 16 system of minimum 64 ODU"s can be controlled and up to 992 IDU"s can be individually mounted and controlled indoor units having minimum 200 mm size colour LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall with an arrangement to integrate with provided fire alarm system.
650Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet foSupplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system.
651Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with theexisting false ceiling and suitable for deflection of 15/30/45°.
652Supplying and installing of collar damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of suitable size
653Refrigerating pipe with insulation Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of below dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
6546.4mm OD
6559.5mm OD
65612.7mm OD
65715.9mm OD
65819.1mm OD
65922.2mm OD
66028.6mm OD
66134.9mm OD
66241.3mm OD
663Drain Piping Supplying and erecting UPVC reinforcedflexible conduit ____ in dia. conforming toI.S. with requirednumberof couplings, PVC bushes, check nuts etc. complete.
66425 MM
66532 MM
666Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1kV Note:Power supply point shall be within 3 m distance from each IDU
667Supplying erecting, testing to 2 core shielded Microphone Communication Cable cable as per specification No. FF-PA/MC
668Cable Tray for Outdoor Copper Piping at Terrace Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 400 mm width & 100 mm height comprising all required standard accessories. Note: All tray shall be with cover plate.
669400X100 mm
670300X100 mm
671SITC of Ventilation System Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 300 cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete300CFM @ 10mm Wg (Fresh Air Fan).
672GSS Ducting Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint.
67324G
67422G
675Supply, fabrication, installation an testing of flexible sheet metal rectangularconstructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete.
676THERMAL INSULATION WORK Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC- 2017.
677ACOUSTIC INSULATION WORK Providing and applying of acoustic insulation for air ducts with 25mm thick, 48 kg/cu.m fiber glass faced with RP tissue and covered with 26 SWG perforated aluminium sheets complete.
678Air Cooled VRF Outdoor Unit Supplying, erecting, testing and commissioning of below capacities,VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation incooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.Air Cooled VRF Outdoor Unit Supplying, erecting, testing and commissioning of below capacities,VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation incooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete. Note:- 1) Rate of duly coated MS fabrictaed stand (C-channel / Angle) with double coat Zinc cromate and paint shall be inclusive in quoted rate. 2) Rate of Lifting, Shifting, proper positioning of ODU"s on stand at Terrace shall be inclusive in quoted rate.
67928 HP
680Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
681Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet foSupplying and installation of high pressure grade required size copperconnection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testingfor leakages confirming the normal operation of the VRV/VRF air conditioningsystem.
682Refrigerating pipe with insulation Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of below dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
6839.5mm OD
68412.7mm OD
68515.9mm OD
68619.1mm OD
68728.6mm OD
68834.9mm OD
689Drain PipingSupplying and erecting UPVC reinforcedflexible conduit ____ in dia. conforming toI.S. with requirednumberof couplings, PVC bushes, check nuts etc. complete.
69025 MM
69132 MM
692Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1kV Note:Power supply point shall be within 3 m distance from each IDU
693Supplying erecting, testing to 2 core shielded Microphonecable as per specification No. FF-PA/MC
694Cable Tray for Outdoor Copper Piping at Terrace roviding & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 400 mm width & 100 mm height comprising all required standard accessories. Note: All tray shall be with cover plate. 300X100 mm
695S SPOT, Recessed Mounted Downlight Narrow Beam 19° Suitable for 45W LED 3000K with Dimmable Driver. Make: FOCUS LIGHTING
696S SPOT, Recessed Mounted Downlight Wide Beam 45° Suitable for 45W LED 3000K with Dimmable Driver. Make: FOCUS LIGHTING
697S SPOT, Recessed Mounted Downlight Very Wide Beam 60° Suitable for 45W LED 3000K with Dimmable Driver. Make: FOCUS LIGHTING 245.1DALI ROUTER-1 242.2POWER SUPPLY -1245.3Key Pad
698Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for 4W-6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with 1 year warranty.
699SITC of 200W Full Power light Source, Warm Cold: 3200K and Cold White: 5600K.6 meters effective range,10000 hours lifespan. 2/4 Channels [4 Control Mode] Automatic/ Rapid Response Sound Active/ Master-Slave Mode / DMX-512 remote controller [Features] Y axis 180 degrees and stable mounting brackets ensure the light can be wall hanging or uplighting. [Occasion] Professional Stage lighting kits, Super bright for Stage show, Home Party, Street live, Cinema, photography , IP 20 protection, Model: Legacy LED-200P-WW, Make: Modern Stage Service.
700SITC of 200watt Plano Convex Spot Light with Having CRI TLCI Values above 95High precision steady color ,No heat, DmX 512 dimming with 2 Channel Beam Angle 15°/ 25° / 45°, 0 ~ 100%, Powder coatedBlack finish housing Rigidly built pressure die-casted Aluminium body LED Easy view display Flicker Free for high FPS Smooth fade in and Fade out Data DmX through 3 / 5 Pin XLR’s Total Power Consumption of 200W IP20 protection. Model: Legacy LED-200PC, Make: Modern Stage Service
701SITC of 100 watt x 4 LED Blinder : Input power: AC100-240V 50HZ/60HZ ,Power consumption: 400W,LED Source: 4pcs high power 100w COB LEDs ,Colors: White and warm white ,Light angle: 60 degree ,Color Temperature: 3000 - 5600K ,Channels: 8CH ,Material: Metal Aluminum Best projection distance: 15-30 meters ,Dimmer: linear dimming 0-100% ,Strobe: 0-25 times /sec ,Control mode: Auto, DMX, Master/Slave DMX, IP 20 protection,Model: Legacy LED-200B, Make: Modern Stage Service
702SITC of LED Fresnel Light with VOLTAGES: 100~240V AC,50/60Hz, POWER CONSUMPTION: 179.6W @ 220V, LIGHT SOURCE: Citizen 200W LED, CORLOUR TEMPERATURE: 3000K, LUMENS: 2982lm~5845lm,BEAM ANGLE: 30°~87°, DIMMER: 1~100% linearly adjustable, CONTROL: DMX512, 5 pin interfaces , 1 channel in standard mode, WORK ENVIRONMENT TEMPERATURE: -20°C~40°C, HOUSING: High-intensity extruding aluminum, IP20, WEIGHT: 6kg, OTHER FUNCTIONS: Low noise(<30dB), CRI:83, Lumens for high light 6000lm, Ideal for television studios, theatres, various conference rooms, multifunctional halls and other locations as functional lighting. Model: Legacy LED-200F, Make: Modern Stage Service
703SITC of 18 x 10W LED Par Light RGBW, Beam Angle 25°/45° complete with RGBW 10W Lamp source x 18 Pcs DmX 512 dimming with 8 ChannelHigh Bright Red, Green, Blue, White LED’s Source Unlimited Color Mixing through DmX 0 ~ 100% Linear dimming In built presets for different colors Strobe Mode 20 times/Sec Data DmX through 3 Pin XLR’s 65dB ~ 130dB Sound sensing capacity Power In and Out Connections High precision colors, Powder coatedBlack finish housing Having Sound Control & Master Slave Auto Run Mode Illuminate theIndoor stage with unlimited colour effectsRigidly built pressure die-casted Aluminium bodyIP20 protection. Model: Legacy LED-180P-RGBW, Make: Modern Stage Service
704SITC of 200 watt LEDProfile Spot with Lamp power: 200 watt, Power Supply 110v-220V 50Hz, Beam Angle 19 Degree,Control: DMX Autorum and master/Slave,CRI:>90,Colour Temprature: 3200K, Shutter:Beam Shaping shutter or plasticgobo projection assembly, IP Rate: 20, Model: Legacy LED-200PS-WW, Make: Modern Stage Service
705300W Beam, Spot, Wash (3 in 1) Moving Head with Input Voltage: AC90/240C, 50-80Hz, Lamp: 15R 300W (OSRAM), Power: 500W, Life Time: 2200 hrs, DMX Channels: 16CH / 24CH / 30CH, Pan: 540° (16bit), Tilt: 245° (16bit), Color Wheel: 13 dichroic filters + white, Rotating Gobo Wheel: 9 Bidirectional and indexable gobos, Static Gobo Wheel: 14 fixed gobos at variable rotation, Strobe: 0-13f/s, random or pulse flash, speed adjustable strobe macro function, Dimmer: 0-100% linear light dimming, Model: BWS-15R,Make: Modern Stage Service
706LED Linear wash lights, Protection Rating : IP66, Control : 512DMX, Power and DMX loop in and loop out for easy of connections. Additional wall mount yoke arrangements for fixing the lights. Power : 24 X 8W, RGBW 4-lN-1 IP65, Beam Angle 25 deg, High power leds 12w each, 32 bit ARM processor dimming, 0-16666 PWM output, the dimming frequency is highly to 600Hz, 4 bit digital display DMX address code, easy to operate,Linear dimming for 0-100%, flicker free, with strobe/gradual change/color change/water effect inbuilt programs, DMX 512 signal control Stand alone, master/slave mode. Multi machine interconnect, Channels : 4/8 DMX channels options. Body: Extruded aluminium. Model: Legacy LED-200CYC, Make: Modern Stage Service
707SITC of Light fixture mouting clamp Customized for suspending on fixed bars on stage Made up ofMS Srip and MS threaded T bolt Complete with black powder coating matt black finish.Safe working load 50 KG, Make: Modern Stage Service
708SITC of Light Fixture dual safety Chain made up of GI wire rope Bundled and twisted together Having load bearing capacity above 50 Kgs, Make: Modern Stage Service
709SITC of Power Distribution Electrical panel having a Incomer of 160A, floor mount / rack mount / wall mount Nuetral separation made using incomer of L&T or Schneider make, Voltmeter, Ammeter display for reading visualization Individual MCB control for 47 outgoing circuits RYB Phase indicators internally wired using IS certified wires and cables Provided with ivery connectors for the internal terminations and external outgoing connecting points Custom built as per specification and project requirement. Model: PD-100, Make: Modern Stage Service
710SITC of Lighting Console with Internal Flash Drive, similar in functionality to a hard disk but faster and more rugged. Provides enough storage for:- The entire Fixture Library of more than 3,000 files, Over a hundred show files, Removable external Memory Stick, Cache the entire Fixture library of more than 3,000 files,Improved method of Fixture selection for Patching, New Locate Fixture button, Fixture Selects (selecting the top row of faders), 2048 Channels, 240 Intelligent Fixtures, 240 Dimmer Control Channels, Theatrical Plotting and Playback functions, Shape Generator for instant creation of patterns and effects, 15 Playback Masters controlling 450 memories, chases or cue lists, MIDI and Bass, Mid, Treble sound to light triggers, Colour VGA output fitted as standard, Type: Pearl 2010, Make: Modern Stage Service
711SITC of DMX Splitter with 6 In 2 Out, "DMX in" and "DMX loop out", High brightness power and data LED"s, Standard XLR5 (optional XLR3 or XLR3 reverse polarity), Internal circuit board carries spare IC"s, operates from any AC mains voltage from 85-265 volts complete etc. with weather proof box, IP Rating 20. Type: DMX-6-2, Make: Modern Stage Service
712SITC of FRLS Copper unarmoured Flexible cable having 3 Core each of 1.5 Sq mm size. Make: Policab/Fenolex/Hevels
7133 Core DmX Cable with Sheathed housing on the cable, well designed insulation, low noise suitable to transmet DmX signa, Make:Falcon/Krystal
714Cable Tray 4"
715GI Boxes with 15 amp sockets
716XLR Connector
717Supplying and erecting LED square / circular Max. 11 W downlighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
718Supplying and erecting LED square / circular Max. 11 W downlighter/Panel Light having pressure die-cast aluminium housing, polystyrenediffuser having system lumens output of Min. 1200 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. rippleof 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with 3 years warranty.
719Supplying and erecting LED square / circular Max. 18 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clipscomplete with 3 years warranty.
720Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail