Tender For Maintenance Of Pump Motor, Repair/ Maintenance Of Centrifugal/ Monoblock/ Submersible Pumpsets Motors, Starters, Lt Panel Board, Bulk Water Meter And Allied Works Etc At Water Supply Installations Under Ge (Cme) Khadki, Pune-Maharashtra

Military Engineer Services-MES has published Tender For Maintenance Of Pump Motor, Repair/ Maintenance Of Centrifugal/ Monoblock/ Submersible Pumpsets Motors, Starters, Lt Panel Board, Bulk Water Meter And Allied Works Etc At Water Supply Installations Under Ge (Cme) Khadki. Submission Date for this Tender is 23-03-2024. Starter Tenders in Pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42502387
Corrigendum : Tender For Maintenance Of Pump Motor, Repair/ Maintenance Of Centrifugal/ Monoblock/ Submersible Pumpsets Motors, Starters, Lt Panel Board, Bulk Water Meter And Allied Works Etc At Water Supply Installations Under Ge (Cme) Khadki
Open Tender
Indian
Maharashtra
Pune
23-03-2024

Tender Details

Maintenance Of Pump Motor, Repair / Maintenance Of Centrifugal / Monoblock / Submersible Pumpsets Motors, Starters, Lt Panel Board, Bulk Water Meter And Allied Works Etc At Water Supply Installations Under Ge ( Cme ) Khadki

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: Maint of pump motor, repair/maintenance of centrifugal/monoblock/submersible pumpsets motors, starters, LT panel board, bulk water meter and allied works etc at water supply installations under GE (CME) Khadki
Sl. No. Item Description
1M&L for disconnecting and removing the PUMP SET from its foundations/ base frame located at different locations, by disconnecting suction, delivery pipes, pump couplers and electrical connections, taking it to workshop for repair, Dismantling and opening up of PUMP assembly complete, removing worn out Gland, bush, shafts, pump Housing, bearing, Gland Packing, Pin locking set, nuts and bolts, washersetc.,and replacing with new parts of same make/model/type including necessary machining works as required, assembling, Balancing and refixing the pump back to its postion after getting repair and making all connections, carry out alignment,and testing for satisfactory function all as specified and as directed for following Pumps:-
2Split type centrifugal Pump set of Make Kirloskar, Model No UP 150/38B, 1450 RPM coupled with 50 HP motor at Main Pump House Bhosari
3Centrifugal pumpset of make Kirloskar model No DB 40/20 coupled with 10 HP motor in MAP Pump House
4Monoblock Centrifugal Pump SetType:KDS 844++Capacity 450LPM@ 38m Head coupled with 7.5HP motor
5Split type centrifugalPump set 12.5 HPof Make Kirloskar, Model No DSM 50/28. (SS No 1)
6Monoblock Centrifugal Pump Set of any capacity but coupled with electric motor upto and including 5Hp
7Material and Labour for disconnecting and removing the MOTOR of any make/model / type, from pump sets and foundations/ base frame located at different pump houses, by disconnectingelectrical connections and pump couplers, taking it to workshop for repair,dismantling stator and rotor assembly, removing burnt out winding wires complete, rewinding the stator with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnishover the complete winding, drying up by heating , assembling back the stator and rotor including replacement of nuts, bolts, studs, Gasket, packing,locking pin, terminal blocks, and terminal bolts and nuts and misc accessories & hardware required for making motor functional, both end bearings (labour only) with same size/make complete for following motors all as specified and as directed :- Note: 1.Bearing shall be measured and paid saperately.
8Single Phase, 240V Motor of capacity upto2 Hp
9Three Phase, 415V Motor of Capacity5Hp
10Three Phase, 415V Motor of capacity 7.5 Hp
11Three Phase, 415V Motor of capacity 10HP
12Three Phase, 415V Motor of capacity 12.5HP
13Three Phase, 415V Motor of capacity 50Hp
14M& L for removing bore well column pipes upto 80mm dia with submersible flat cable of any type and dismantling and taking up/down SUBMERSIBLE PUMP & Motor ASSEMBLY, shifting to workshop and removing unserviceable spares, replacing with new spares such impeller, bushes distance bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnishover the complete winding , drying up by heating , assembling back and testing for proper functionincluding necessary machining works as required , bringing back and reinstalling into the bore well all as specified and as directed. Note: 1.Bearing shall be measured and paid saperately.
15Open well submersible pump capacity 5 HP, AC 3 Phase, 50 HZ.
16Open well submersible pump capacity 10 HP, AC 3 Phase, 50 HZ.
17Open well submersible pump capacity 40 HP, AC 3 Phase, 50 HZ.
18Supply and fix Pump shaft made of stainless steel for Kirloskar make pumpset of following models:-
19Split type centrifugalPump set of Make Kirloskar, Model No UP 150/38B, 1450 RPM coupled with 50 HP motor.
20Centrifugal Pump set of Make Kirloskar, Model No DSM 50/28 coupled with 12.5 HP motor.
21Monoblock centrifugal pumpset of make Kirloskar model No DB 40/20 coupled with 10 HP motor
22Supply only tyre coupling suitable for centrifugal pumpset coupled with 50 HP motor along with flanges, nuts, bolts, washers, etc incluiding all cutting key and to suit shaft of pumpset and motors all as directed by Engr-in-charge.
23All as per item No.5 above, but for 10HP
24All as per item No.5 above, but for 12.5 HP
25Supply only nylon rope of 20mm dia for bore well pump
26Supply & fix Mild Steel bore well cap suitable for bore size upto 250mm
27Supply only antifriction heavy duty ball bearings 6305 Make: SKF
28Supply only antifriction heavy duty ball bearings 6306 Make: SKF
29Supply only antifriction heavy duty ball bearings 6307 Make: SKF
30Supply only antifriction heavy duty ball bearings 6308 Make: SKF
31Supply only antifriction heavy duty ball bearings 6309 Make: SKF
32Supply only antifriction heavy duty ball bearings 6312 Make: SKF
33Supply only antifriction heavy duty ball bearings 6313 Make: SKF
34Supply only antifriction heavy duty ball bearings 6203 Make: SKF
35Supply only antifriction heavy duty ball bearings 6212 Make: SKF
36Supply and install CI foot valve of size 250mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
37Supply and install CI foot valve of size 200mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
38Supply and install CI foot valve of size 150mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
39Supply and install CI foot valve of size 100mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
40Supply and install CI foot valve of size 80mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
41Supply and install CI foot valve of size 50mm all as per IS 4038 Class PN 0.2 with taking down old u/s foot valve
42Supply and install fully automatic Starter Star Delta typewith single phase protection feature suitable for operation on AC, Three phase four wire, 415 Volts, 50 Hz supplyfor Motor of capacity15HP with relay range 9-15Amps completewith taking down old u/s starter of any type
43Supply and install DOL starter type MN in sheet steel enclosure suitable for AC, Three phase, 415 Volts, 50 Hz supplyand Motor capacity10HP with relay range 9-15Amps completewith taking down old u/s starter of any type
44Supply and install fully automatic Starter Star Delta typewith single phase protection feature suitable for operation on AC, Three phase four wire , 415 Volts, 50 Hz supplyfor Motor of capacity 50 HP with relay range 30-50 Amps completewith taking down old u/s starter of any type
45Supply and install DOL starter type MK-1 in sheet steel enclosure suitable for AC, Three phase, 415 Volts, 50 Hz supplyand Motor capacityup to 7.5HP with relay range 11-18Amps completewith taking down old u/s starter of any type
46Supply and install submersible pump controller in sheet enclosure type MU-G for 415V, 3Ph electric submersible motor of capacity up to 6Hp. with taking down old u/s pump controller of any type
47All as per item No.29 above, but for motor capacity up to 10Hp
48All as per item No.29 above, but for motor capacityupto 12.5Hp
49S & F Thermal overload relay range 3 to 5 Amps including taking down the old relayincuiding material for wiring if required complete all as specified and directed .
50S & F Thermal overload relay range 6 to 10 Amps including taking down the old relayincuiding material for wiring if required complete all as specified and directed .
51S & F Thermal overload relay range 9 to 15 Amps including taking down the old relayincuiding material for wiring if required complete all as specified and directed .
52S & F Thermal overload relay range 20 to 33 Amps including taking down the old relayincuiding material for wiring if required complete all as specified and directed.
53S & F Thermal overload relay range 30 to 50 Amps including taking down the old relayincuiding material for wiring if required complete all as specified and directed .
54S & F in replacement DIN Type Fuse 200 A suitable for HRC fuse kit.
55S&F in replacement HRC fuse base type HN size 2 & 3for capacity 300 A as per existing make and specifications all as specified and directed.
56S & F in replacement Single Phase preventor relaySPPR type Sz5 (6 Wire), 415V
57S & F in replacement Single Phase preventor relaySPPR type SDz5, 415V.
58S&F in replacement HRC fuse base for capacity 80-250 A.
59S & FIlluminated Push Button Projecting Head complete all as specified and directed in RED/GREEN in color, 240V AC,Cat No EG03PDL, Make: L&T/HPL with taking down old u/s push button of any type
60S & F in replacement of LED Indication lamp for LT Panel board RED/YELLO/BLUE,Surface Mounted Device LED technologyLow Power consumption < 0.6W Low Voltage GlowProtection (LVGP) .
61Supply, laying, connecting and testing Submersible flat cable 3 core 2.5 Sqmm PVC insulated and PVC sheatehed with taking down old u/s flat cable of any size and any type all as specified and directed by Engineer In Charge
62Supply, laying, connecting and testing Submersible flat cable 3 core 6 Sqmm PVC insulated and PVC sheatehed with taking down old u/s flat cable of any size and any type all as specified and directed by Engineer In Charge
63Supply, laying, connecting and testing Submersible flat cable 3 core 10 Sqmm PVC insulated and PVC sheatehed with taking down old u/s flat cable of any size and any type all as specified and directed by Engineer In Charge
64Supply and Fix 415V, 50Hz, four pole MCCB 400A, 50KA with taking down old u/s MCCB from existing panel all as specified and directed by Engineer In Charge
65Supply and fix in replacement of 3 pole MCCB of 250A capacity with S.C. rating of 35kA,thermal and magnetic setting with provided leads on iron frame/lamination board as per existing make and specifications all as specified and directed.
66S & F in replacement of Power Contactor 3-Pole with AC Coil 160 Amps along with Aux. Contacts 02NO & 02NC ,440 volts 50Hz MNX 140asin the existing panel, connecting up and testing all in repairs including material for wiring if required as specified and as directed.
67Supply and Fix in replacement of 3 pole MCCB 100A capacity with S.C. rating of 50kA, 415V, 50Hz, thermal and magnetic setting with provided leads on iron frame/lamination board ,with taking down old u/s MCCB from existing panel all as specified and directed by Engineer In Charge
68S & F in replacement Power Contactor 3-Pole with AC Coil 100 Amps along with Aux. Contacts 02NO & 02NC ,440 volts 50Hz MNX 110 asin the existing panel, connecting up and testing all in repairs including material for wiring if required as specified and as directed.
69S& F in replacement of Non retrun valve (NRV) without by pass arrangement including provision of joining material such as insertion sheet 3mm thick, nut & bolts all as required at site 80mm dia bore ISI marked complete with rubber gasket all as directed.
70S& F in replacement of Non retrun valve (NRV) without by pass arrangement including provision of joining material such as insertion sheet 3mm thick, nut & bolts all as required at site 100mm dia bore ISI marked complete with rubber gasket all as directed.
71S& F in replacement of Sluice Valve Class PN 1.6 without by pass arrangement including provision of joining material such as insertion sheet 3mm thick, nut & bolts all as required at site 100mm dia bore ISI marked complete with rubber gasket all as directed.
72S& F in replacement ofSluice Valve Class PN 1.6 without by pass arrangement including provision of joining material such as insertion sheet 3mm thick, nut & bolts all as required at site 150mm dia bore ISI marked complete with rubber gasket all as directed.
73S& F in replacement ofSluice Valve Class PN 1.6 without by pass arrangement including provision of joining material such as insertion sheet 3mm thick, nut & bolts all as required at site 200mm dia bore ISI marked complete with rubber gasket all as directed.
74M&L for Painting of pump sets & motor assembly of capacity 5Hp to 15Hp located at various installations comprising electric Motor, pump, base frame, suction and delivery pipe lines inside & outside of pump house, valves any type and size up to 100 mm dia withTwo coat of synthetic enamel paint of approved colour including scrubbing / cleaning all metalicsurfaces before painting and writing SM/MES No. etc, all as specified and directed
75All as per Item No.57 above, but for pump Motor of capacity 20hp to 50Hp and pipe size upto 350MM
76Trimming of tree exc. 30 cm girth and n.exc 100cm girth including cutting of trunk and branches and disposal of unserviceable material to a distance n exc. 50 m and clearing site all as specified and directed.
77M&L for PCC 1:2:4 type B-1 and 20mm graded stone aggregateincluding plastaring for foundation of pump set & Motor
78M & L for carry out water quality anyalysis for bacterial, chemical and biological analysis including for collection of water samples from the pump house and one of the location as specified by Engineer In Charge and testing from govt approved testing laboratory/FHHL lab, submitting of reprort for minimum following parameters (a) Turbudity (NTU) (b) pH (c) Total Hardness as CsCO2 (mg/l) (d) Sulphate as SO2 (mg/l) (e) Iron as Fe (mg/l) (f) Magnesium as Mg (mg/l) (g) E-Coli or thermotolerant coliform bacteria (h) Remarks of Govt water testing lab
79Material & labour for Earthing using galvanised iron earth plate electrode of size 60cm X 60cm X 6mm thick burried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanised iron wire of 4mm dia by means of bolts, nuts, check nuts and washers and protected by light grade 15 mm dia galvanised iron pipe and GI pipe light grade 20mm bore for watering, including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 3 of SSR Part-Ifor different capacities pumpsets.
80Note :
81The unit rate shall include GI protection pipe 15mm dia 7.5Mtr, GI water pipe 20mm dia, wire mesh, funnel, excavation,RCC pit cover, P.C.C chamber pit,. test point, Main earthing lead from earth electrode to test point upto 7.5 metre and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made.
82PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fitting junctionetc shall be deemed to be included in the unit rate.
83CI pit cover or precast RCC 1:2:4, type B-1, 80mm thick reinforced with XPM (weighing not less than 4 Kg/sqm in lieu of cast iron cover).
84M & L for framed work such as grills, gratings, bar, flat plates etc.conforming to Fe.290.Gde-E-165 with two coat of synthetic enamaled paint over coat of red oxide primer including preparation of new steel surface incl taking down old unsrviceable one all as directed and specified by Engineer In Charge
85M & L for cleaning of strainer 400mm dia including opening of strainer top cover by removing nut/bolts, removal of strainer screen and taking out dirt, mud, foreign particles accumulated inside strainer, assembling back and replacemnt of worn out nut bolts and gasket all as specified and directed by Engineer In Charge
86Supply only calcium hypochlorite (calcuim based granular disinfectant, 65-70% chlorine content ) packing 20-25Kg/40-45 Kg drum Make : Puri chlor (Sree Rayalseema) or other equivalent make approved by E-IN-C Branch .
87M & L forrepair of u/s water meter 400mm dia incl Transportationto & from workshopand replacement of u/s spares for water meter like worn out gear assembly, impeller, spindle, nut bolts, washers, rubber gaskets, packing set including Calibration & testing at MIDC laboratory Mumbai as per MIDC norms. Installation of repaired water meter of 400mm diaincluding taking down existing water meter, replacement of rubber gasket, nut bolts, cleaning and removing accumulated mud, dirt and foraign material from strainer assembly. provision ofstrainer screen made up of perforated steel sheetall as specified and as direted by Engineer In Charge.
88M& L in replacement of MS Channel ironbase frame suitablefor 50 HP Pump set including grouting & necessary PCC required as specified & directed
89M& L in replacement of MS Channel ironbase frame suitablefor30 HP Pump set including grouting & necessary PCC required as specified & directed
90M& L in replacement of MS Channel ironbase frame suitablefor12.5 HP Pump set including grouting & necessary PCC required as specified & directed
91M& L in replacement of MS Channel ironbase frame suitablefor10 HP Pump set including grouting & necessary PCC required as specified & directed
92M& L in replacement of MS Channel ironbase frame suitablefor7.5 HP Pump set including grouting & necessary PCC required as specified & directed
93Servicing / over hauling ofCentrifugal/monoblock/submersible Pump/motor sets Installed at Pump House/Installations coupled with upto 15 HP Motor along with following others repairs. Note : Minor items like grease, gland packing are deemed to include in quoted rate .
94Servicing / over hauling ofCentrifugal/monoblock/submersible Pump/motorsets Installed at Pump House/Installations coupled with upto30- 50 HP Motor along with following others repairs. Note : Minor items like grease, gland packing are deemed to include in quoted rate .
95M & L for attending electrical breakdown in Pump panel/Starter, repairing/servicing/replacement unserviceable parts providing necessary copper cable, lugs terminals connection cleaning and re-fitting /re-setting coil NOC-1 and NOC-2, fixing of MCCB, nut-bolt, coil etc complete all as specified and directed. (Note: Spare parts will be measured and paid separately under above items as per schedule A)
96M&L forLT indoor/outdoor Panel/feeder pillar box any type by disconnecting and removing all the incoming and outgoing cable connection from MCCBs, cleaning of dust with air blower, burnt busbars, burnt thimbles,any type of insulators, cable tray, sprial piping, necessary cable tie, reconnections after proper cleaning of contacts with CRC solution and painting of complete panel including stand and door/back outside(after proper scrubbing) with synthetic enamel paint one coat as per specified colour code including writing of panel/feedar panel location using black systhetic paint and reconnecting the dismantled LT cables etc. complete all as specified and directedby Engr -in- charge. Note : (i) Cost of labour, cotton waste and T&P required for upkeeping/maint work is inclusive in quoted rate.
97Dismantling / taking down existing gas chlorinator and deposing to MES store yard by removing chlorine gas if any inside the water reservoir with all safety factor .
98Overhauling/Servicing of Granular Chlorine solution dosing system comprising of tank with agitator with shaft and blade mounted on tank with high pressure single head gear motored adjustable dosing pump with non metallic liquid endsincluding re assembling the dosing system complete all as specified (Note: Spare parts for replacementwill be measured and paid separately underrespectiveitems of this BOQ here-in-after).
99Supply only,oil seal for dosing pump motor.
100Supply only, head screw for dosing pump motor .
101Supply only, spacer for dosing pump motor.
102Supply only, alter head screw for dosing pump motor .
103Supply only, spring (small) for dosing pump motor.
104Supply only, spring (retention) for dosing pump motor .
105Supply only, diaphagm for dosing pump motor.
106Supply only, electronic pulsator unitfor dosing pump motor .
107Supply only, transformer for dosing pump motor .
108Supply only, shaftfor dosing pump motor.
109Supply only, inlet/outlet nozzlefor dosing pump motor .
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail