National Fertilizers Limited-NFL has published Tender For Miscellaneous Electrical Jobs On Arc Basis In Factory And Township At Nfl Bathinda. Submission Date for this Tender is 18-04-2024. Man Power Supply Tenders in bathinda Punjab. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 28-Mar-2024 | duedateextension1 | Date | 08-04-2024 |
2 | 08-Apr-2024 | duedateextension2 | Date | 18-04-2024 |
Sl. No. | Item Description |
1 | Laying of 11/3.3 KV PVC/ XLPE/ PILC cable in trays, structures, pipes, and trenches etc. Of any size. |
2 | Laying of LT PVC/ XLPE cables in trays, structures, pipes, trenches etc. of following sizes: |
3 | Cable up to & including 3/4x25mm2,Control cables & Telephone Cables of all sizes with clamping etc. |
4 | -Do- but without clamping |
5 | Same as 2.00 but above 3/4x25mm2 & upto3/3.5x70mm2 with clamping etc. |
6 | -Do- but without clamping etc. |
7 | Same as 2.00 but above 3/3.5x70mm2 & upto 3/3.5x185mm2 with clamping etc. |
8 | -Do- but without clamping etc. |
9 | Same as 2.00 but above 3/3.5x185mm2 & upto3/3.5x400mm2 with clamping. |
10 | -Do- but without clamping etc. |
11 | Laying of 11/3.3 KV PVC/ PILC/ XLPE armoured power cable under the ground including supply of bricks and sand. |
12 | Making of straight through joint of 11/ 3.3 KV PVC/ PILC/ XLPE armoured power cable of any size with Heat Shrinkable Jointing Kit |
13 | Making of End Termination Joint (INDOOR) of 11/ 3.3 KV PVC/ PILC/ XLPE armoured power cable of any size with Heat Shrinkable Jointing Kit |
14 | Making of straight through joint of LT armoured Power Cable of size 120 Sq.mm to 240 Sq.mm with Heat Shrinkable Jointing Kit. |
15 | Laying of 1.1 KV PVC/ XLPE armoured power cable under the ground including supply of bricks and sand if required. |
16 | Cable up to & including 3/4x25mm2,Telephone cable/control cable of any size. |
17 | -Do- but successive cable. |
18 | Above 3/3.5x25 mm2 to & including 3/3.5x70mm2 |
19 | -Do- but successive cable. |
20 | Above 3/3.5x70 mm2 to & including 3/3.5x185mm2 |
21 | -Do- but successive cable. |
22 | Above 3/3.5x185 mm2 to & including 3/3.5x400mm2 |
23 | -Do- but successive cable. |
24 | Removing of 1.1KV/3.3KV/11KV PVC/PILC/XLPE underground cable of Size: |
25 | Up to & including 3/3.5x70mm2, Control Cable/ Telephone cable of any size |
26 | -Do- but successive cables. |
27 | All sizes Above 3/3.5x70mm2 |
28 | -Do- but successive cables. |
29 | Removing of 1.1KV/3.3KV/11KV PVC/PILC/XLPEcable from trenchs,tray,pipes,or structure. |
30 | Cables up to & including 3/4x70mm2, Control / Telephone cable of any size |
31 | Cables of all sizes above 3/3.5x70mm2 |
32 | Removing of 1.1KV/ 3.3KV/ 11KV underground cable and laying of new or existing cable in its place including supply of bricks and sand if required |
33 | Cable up to & including 3/3.5x70mm2, Control / Telephone cable of any size |
34 | -Do- but successive cables. |
35 | Cables of all sizes Above 3/3.5x70mm2 |
36 | -Do- but successive cables. |
37 | Pulling of cable in trench / pipe/ tray etc.to bring out margin at the end for its retermination:- |
38 | Pulling up to length of 25 MR for cable size up to 3/3.5x70mm2, Control Cable/ Telephone Cable of any size. |
39 | Pulling up to length of 25 MR for cable size above 3.5x70mm2 & up to 3/3.5x185mm2. |
40 | Do- but for cable size above 3x3.5 x185mm2 and up to 3/3.5x400mm2. |
41 | Pulling up to a length of 50 M for cable size up to 3.5x70mm2 |
42 | Pulling up to a length of 50 M for cable size above 3.5x70mm2 & up to 3.5x185mm2 |
43 | Pulling up to a length of 50 M for cable size above 3.5x185mm2 & up to 3.5x400mm2 |
44 | Pulling up to a length of 150 M for cable size up to 3.5x70mm2 |
45 | Pulling up to a length of 150 M for cable size above 3.5x70mm2 & up to 3.5x185mm2 |
46 | Pulling up to a length of 150 M for cable size above 3.5x185mm2 & up to 3.5x400mm2 |
47 | Tracing of cables armoured/ unarmoured, power/ control/ telephone, HT/LT of following sizes laid on vertical and horizontal cable trays up to length of 50 meters or part thereof |
48 | Cables up to size of 3.5x70 mm2 and control cable up to 24 cores/Telephone cable up to 100 pairs |
49 | Cables above 3.5x70mm 2 and up to 3.5x185 mm2 / Telephone Cable above 100 Pairs. |
50 | Cables above 3.5x185 mm2 and up to 3.5x400 mm2 |
51 | MCB Erection, Testing and Commissioning of following sizes of lighting DBs/ MCB boxes |
52 | 3 phase lighting DB of any number of outlets |
53 | Single phase lighting DB |
54 | MCB box with 3 phase MCB/3 phase power plug |
55 | MCB box with 2 pole MCB |
56 | MCB box with single pole MCB/single phase power plug |
57 | Removal of following lighting DBs/ MCB boxes etc. |
58 | 3 phase lighting DB of any number of outlets |
59 | Single phase lighting DB |
60 | MCB box with 3 phase MCB/3 phase power plug |
61 | MCB box with 2 pole MCB |
62 | MCB box with single pole MCB/single phase power plug |
63 | Replacement of single/ double/ triple pole MCB/ Plug sockets as under: |
64 | Single pole MCB/ Single phase power plug |
65 | Double pole MCB |
66 | Triple/four pole MCB/3 phase plug socket |
67 | 3 phase lighting DB of any number of outlets |
68 | MCB box with single pole MCB/power plug |
69 | Writing of Identification name/ number on electrical equipments with red/white colour paint of size |
70 | i) Letter up to and including 1" height |
71 | ii) Letter above 1" but up to and including 2" |
72 | iii) Letter above 2" but up to and including 4" |
73 | iv) Letter above 4" but up to and including 8" |
74 | Painting of any surface of Electrical equipments.(One coat of Primer & two coats of finished enameled synthetic paint) |
75 | Transportation of material/ equipment from one plant to another or from main stores to any plant / electrical workshop excluding supply of any material or transport. |
76 | HT/LT Motors up to 3.7 KW rating. |
77 | -Do- but above 3.7 & up to 11 KW rating. |
78 | -Do- but above 11 KW & up to 37 KW rating. |
79 | -Do- but above 37 KW & up to 75 KW rating. |
80 | -Do- but above 75 KW & up to 125 KW rating. |
81 | -Do- but above 125 KW & up to 220 KW rating. |
82 | -Do- but above 220 KW & up to 480 KW rating. |
83 | -Do- but above 480 KW & up to 990 KW rating. |
84 | Any material weighing more than 100 Kgs. But up to 250 Kgs. |
85 | Any material weighing more than 250 Kgs. |
86 | WORKSHOP Making formers of wood of different sizes for making coils for motors |
87 | MRS & CPP SWITCHYARD Cleaning including uprooting of wild growth grass/rank vegetation/ bushes from 132 KV Switch Yard as per instructions of Engineer-in-charge of the following areas: |
88 | In MRS approx. area 14500 Sq. Meter. |
89 | In CPP approx. area 1900 Sq. Meter. |
90 | Excavation of pebbles including uprooting of vegetation, bushes, washing of pebbles, stacking of serviceable pebbles after washing, disposable of unserviceable pebbles, malba, waste materials from transformer bays, spreading of serviceable pebbles and levelling |
91 | In Ammonia Plant approx. pebbled area 26.5 Sq. Meter. |
92 | In Ammonia Plant approx. pebbled area 31Sq. Meter. |
93 | In Urea Plant approx. pebbled area 26.5 Sq. Meter. |
94 | In Urea Plant approx. pebbled area 31 Sq. Meter. |
95 | In DM Plant approx. pebbled area 26 Sq. Meter. |
96 | In SGP approx. pebbled area 21 Sq. Meter. |
97 | In CPP approx. pebbled area 43 Sq. Meter. |
98 | In CHP approx. pebbled area 26.5 Sq. Meter. |
99 | In RWFP approx. pebbled area 26.5 Sq. Meter. |
100 | In Auxiliary Sub Station approx. pebbled area 45 Sq. Meter. |
101 | In Ammonia Plant DG Set Yard pebbled area 136.32 Sq. Mr. |
102 | In Ammonia Plant 6.3 MVA T/F Yard pebbled area 80.64 Sq. Mr. |
103 | In Ammonia Plant 2 MVA T/F Yard pebbled area 148 Sq. Mr. |
104 | TELEPHONE Erection Testing and Commissioning of Telephone DBs of following sizes |
105 | Telephone DB up to 10 pairs |
106 | Telephone DB above 10 pairs and up to 50 pairs |
107 | Telephone DB above 50 pairs |
108 | Dismantling of telephone DBs of following sizes |
109 | Telephone DB up to 10 pairs |
110 | Telephone DB above 10 pairs and up to 50 pairs |
111 | Telephone DB above 50 pairs |
112 | Replacement of telephone DBs of following sizes |
113 | Telephone DB up to 10 pairs |
114 | Telephone DB above 10 pairs and up to 50 pairs |
115 | Telephone DB above 50 pairs |
116 | Laying, termination & comm.Of telephone cables in existing conduit/ batten/ casing capping up to 5 pairs. Dismantling & relaying if required also included. |
117 | Replacement of telephone socket / plug top/ ceiling rose etc. |
118 | Erection & commissioning of telephone socket / ceiling rose on new switch board |
119 | General maintenance including checking of incoming/ outgoing cables/ wires connections & proper sealing of telephone DBs of size: |
120 | Up to 10 pairs. |
121 | Above 10 pairs up to 50 pairs. |
122 | Above 50 pairs up to 200 pairs. |
123 | Above 200 pairs. |
124 | OVERHEAD LINES Installation of single ACSR conductor squirrel/ panther/ ferret/ dog on existing poles including binding, stringing etc. per span of 60 MR maximum. |
125 | Installation of GI stay wire set 7x8 SWG complete with accessories. |
126 | Adjustment/ Repair of existing stay wire |
127 | Installation of 6 SWG wire guard between neutrals of overhead line. |
128 | Erection of LT pin insulators on existing cross arms including hardwares. |
129 | Erection of LT shackle insulators on existing cross arms including hardwares. |
130 | Stringing of single span single ACSR conductor squirrel/ panther/ ferret/ dog or shield/ guard wire between two poles of LT/ HT overhead line (max. Span length 60m) |
131 | Checking of connection of PG clamps/ binding wire on LT/HT overhead line. |
132 | Mtc. Of Double Circuit Towers of 132KV Overhead Line from CPP to MRS as per Scope of Work |
133 | Mtc. Of Single Circuit Tower/ Gantries of 132KV Overhead Line from CPP to MRS as per Scope of Work |
134 | Replacement of Jumpers of any size on LT/HT overhead line incl. Cleaning of Insulators |
135 | Checking & Tightening of Guard wires. |
136 | Replacement of overhead line ACSR conductor of any size & type per conductor per span of 60 M max. |
137 | Fabrication of steel cross arms and its erection on existing poles including the accessories, hardwares etc. |
138 | Replacement of GI stay wire /stay wire insulator. |
139 | Dismantling of 3 phase LT overhead line of panther / ferret / squirrel/ dog ACSR conductor including accessories between two poles having a span length of max 60 MR. |
140 | -Do-but 11 KV HT overhead line (span of max 60 MR) |
141 | Dismantling of complete stay wire set from RCC/ Steel Tubular Poles. |
142 | Dismantling of overhead line ACSR conductor including hardware per conductor /span of 60 MR max. |
143 | Erection of RCC / Steel Tubular Pole/ Lighting Mast etc. |
144 | Up to height of 12 ft. |
145 | Above 12 ft. & up to height of 24 ft. |
146 | Above 24 ft. |
147 | Installation of temporary Pole of any size and removing there after. |
148 | Erection/ Dismantling/ Replacement of Steel Tubular Pole of height up to 12 feet by cutting/ welding/ clamping |
149 | Dismantling of fabricated Steel/ RCC / Steel Tubular Pole/ Lighting Mast. |
150 | Up to height of 12 ft. |
151 | Above 12 ft. & up to height of 24 ft. |
152 | Above 24 ft. |
153 | EARTHING Installation, testing & commissioning of earthing station |
154 | Maintenance of earthing station including supply of salt (if reqd.) for reconditioning and measuring / recording of earth resistance value. |
155 | Erection of earth electrode only in the existing earth pit |
156 | Laying of GI / AL EARTH STRIP in ground or on tray, structure etc of following sizes |
157 | Up to 150mm2 |
158 | Above 150mm2 |
159 | Refixing of existing earth strip. |
160 | Dismantling of GI / AL EARTHING of any size from ground or structure, tray etc. |
161 | Laying/ Termination/ Dismantling of 6/8 SWG GI/AL wire on existing RCC poles or other structure/ wall/ under ground etc. including supply of hardwares like bolts, nuts, clamps etc. As reqd |
162 | Installation of single spike GI Rod lightening arrestors over cooling tower or any tall structure |
163 | Dismantling of single spike GI rod lightening Arrester over Cooling Tower or any tall Structure. |
164 | SWITCH FUSE UNITS/CONTROL GEARS Installation/ Dismantling OF Push button station/ motor starter/ TPN/ SPN or Change Over switches/ Flame Proof outlets: |
165 | Up to 125 amps. |
166 | Above 125 Amps. |
167 | Dismantling / Erection / Replacement of MS/ CI/ PVC junction box/ Telephone DB of any size in / from wall or RCC ceiling / column etc.: |
168 | Erection |
169 | Dismantling |
170 | Replacement/ Refixing |
171 | Removal of MS/ CI box/ wooden board from masonry wall or RCC column |
172 | Glanding or reglanding of cables with single / double compression type cable glands of size up to 1" dia. |
173 | -Do- but of size above 1" dia & up to 2" dia. |
174 | -Do- but of size above 2" dia. |
175 | DOMESTIC WIRING Laying, Termination & Commissioning of PVC insulated flexible Copper wire single core 6mm2/ Flexible cable of size up to 2X6mm2/ 3x1.5mm2 flexible Cable on existing wooden batten/ PVC Casing capping/ Conduit pipe including supply of all the required material |
176 | Laying, Termination & Commissioning of PVC insulated flexible Copper wire single core 6mm2/ Flexible cable of size up to 2X6mm2/ 3x1.5mm2 in PVC Casing capping/ Conduit pipe including supply of all the required material as specified in Scope of Work. |
177 | With supply of PVC Casing capping/ Conduit Pipe of size up to 1" |
178 | With supply of PVC Casing capping/ Conduit Pipe above 1" up to 2" |
179 | Replacement of worn out wooden batten/ PVC or MS conduit/ PVC casing capping with PVC casing capping/ conduit pipe of size 1" including supply of all material except wire/ cable. |
180 | -Do- but of size above 1" and up to 2" |
181 | Installation of MS switch board with 3 mm thick sunmica sheet of size: |
182 | 10"X12" |
183 | 10"X8" |
184 | 9"X4" |
185 | 7"X4" |
186 | 4"X4" |
187 | Installation of Wooden boards of following sizes |
188 | 8"X10" & above |
189 | 7"X4" |
190 | 4"X4"/ Round Block. |
191 | Dismantling of single core Al/ Cu conductor cable of size up to 6mm2 or 3 core flexible cable from wooden batten/ PVC conduit/ PVC casing capping |
192 | -Do- but relaying as well. |
193 | Replacement of 14 / 16 SWG earth wire in conduit or on batten. |
194 | Wiring for Light/ Fan/ Exhaust fan/ 5 Amp Socket point in recessed conduit with PVC insulated copper conductor of size 1.5 Sq. mm. including supply of all material for following sizes: |
195 | Short point |
196 | Medium point |
197 | Long point |
198 | Circuit wiring in recessed conduit with following size of conductor including supply of all material |
199 | With 1.5 Sq. mm. Cu. conductor. |
200 | With 2.5 Sq. mm. Cu. conductor. |
201 | With 4 Sq. mm. Cu. conductor. |
202 | With 6 Sq. mm. Cu. conductor. |
203 | Circuit wiring in exiting conduit with 1.5 Sq. mm. Cu conductor with supply of material: |
204 | - Do - but 2.5 Sq. mm. |
205 | - Do - but 4 Sq. mm. |
206 | - Do - but 6 Sq. mm. |
207 | Wiring for Twin control Light point in PVC Casing capping/ Recessed PVC Conduit with copper conductor of size 1.5 Sq. mm. including supply of all material for following sizes: |
208 | Short point. |
209 | Medium point |
210 | Long point. |
211 | Wiring for 15 Amp Socket point in PVC Casing capping/ PVC Recessed conduit with copper conductor of size 4 Sq. mm. including supply of all material for short point: |
212 | -Do- but with 6 Sq. mm.Cu. conductor. |
213 | TOWNSHIP Attending of no light complaints of following houses/ buildings in township/ CISF colony: |
214 | A/B/C/D type house/ Residential Rooms of Expert Hostel & Sub-feeders of Public Building in normal working hours. |
215 | A/B/C/D type house/ Residential Rooms of Expert Hostel & Sub-feeders of Public Building during odd hours. |
216 | Installation and removal of temporary lights/ extension boards as required in township. |
217 | Temporary installation of Lighting Circuit having max. 30 lamps up to 200W ratings in parallel and removing the same after completion of job as per scope of work. |
218 | Temporary installation of Main Lighting/ Power Distribution Board and removing the same after completion of job as per scope of work. |
219 | Temporary installation of Flood Lights of any rating including its control gears on Poles and removing after completion of job. |
220 | Replacement of 5 or 15 amp domestic /industrial / switch /socket /plug top /lamp holder /kit kat /bell push /buzzer /round block /fuse /fan capacitor /regulator/repair of fan regulator and connections and or disconnection of electrical appliance including attending of minor faults. |
221 | Erection & commissioning of 5 /15 Amp switch /socket /fan regulator on a new switchboard. |
222 | Refixing of domestic light fitting of any type |
223 | Maintenance of glow sign boards installed at a height of 6 M approx. |
224 | Maintenance of pole mounting box. |
225 | Installation /removal / replacement of single / 3 phase energy meter. |
226 | Installation |
227 | Removal |
228 | Replacement |
229 | General maintenance of single / three phase meter boards of residential units in township & CISF colony/ public buildings. |
230 | TEMPORARY CONNECTION Temporary laying of armoured/ unarmoured cables of following sizes & lengths for connecting Hand Lamp / Flood Light / Extension Board / Welding Set etc. of any type & size & its removal, if reqd; after completion of job. |
231 | Flexible cable up to 4x2.5mm2 & up to 15 MR. Length. |
232 | -Do- but above 15 MR & up to 50 MR Length. |
233 | -Do- but above 50 M and up to 100 MR. Length. |
234 | Armoured Cable of size up to & including 4 x25mm2 & length up to 100 M. |
235 | -Do- but length above 100 M & up to 300 MR. |
236 | Armoured Cable of size above 4x25 mm2 but up to 3.5x70mm2 & length up to 100 M. |
237 | -Do- but length above 100 M & up to 300 MR |
238 | Armoured Cable of size above 3.5x70 mm2 but up to 3.5x185mm2 & length up to 100 M. |
239 | -Do- but length above 100 M & up to 300 MR. |
240 | Armoured Cable of size above 3.5x185mm2 & length up to 100 MR. |
241 | -Do- but length above 100 M & up to 300 MR. |
242 | LIGHTING Erection, testing & comm. of LED street light fixture up to 2x18 W on existing poles including supply of B-class GI pipe bracket 1 MR long. |
243 | Erection, testing & comm. of following type of lighting fixture including control gear: |
244 | LED fitting up to 2X18wW fitting of any type& size. |
245 | Well glass LED fitting of any type & size up to 50 W |
246 | Post top lantern LED of any type & size up to 50 W. |
247 | LED Flood light of any type & size up to 80 W. |
248 | LED Flood light of any type & size up to 200 W. |
249 | LED Street light fitting of any type & size up to 75 w. |
250 | Flame proof / Increased Safety LED light fitting of any type & size |
251 | Aviation light fitting of any type & size |
252 | Assembly of light fitting including wiring of any type & size |
253 | Replacement of tube rod/lamp /glass/ wire guard gasket/ lamp holder etc |
254 | Removal of fault/ replacement of any single accessory, in lighting fixture any type and size up to 200W as stated in item 69.00 |
255 | -Do- but in street light fixture. |
256 | -Do- but in increased safety / flameproof lighting fixture. |
257 | -Do- but in aviation lighting fixture. |
258 | Removal of fault/replacement of 2 or more accessories in lighting fixture of any type &size up to 200W as stated in 69.00 |
259 | -Do- but in street light fixture. |
260 | -Do- but in increased safety /flameproof lighting fixture. |
261 | -Do- but in aviation lighting fixture. |
262 | Removal of fault/ replacement of any single accessory in lighting fixture of any type &size above 200 was stated in item 69.00 |
263 | -Do- but in street light fixture. |
264 | -Do- but in increased safety flameproof lighting fixture. |
265 | Same as item 70.00 but removal of fault /replacement of 2 or more accessories. |
266 | -Do- but in street light fixture. |
267 | -Do- but in increased safety flameproof lighting fixture. |
268 | Replacement of gen. lighting fixture of any size or type up to 200 w. |
269 | -Do- butflood light fixture of any size & type. |
270 | -Do- but increased safety/Flameproof light fixture. |
271 | Dismantling of LED light fitting of upto 50W |
272 | Dismantling of any LED fitting above 50W to upto100 W. |
273 | Dismantling of flood light fitting above 100 W. |
274 | Dismantling of aviation light fitting. |
275 | Maintenance of lighting board/junction boxes/terminal box etc. |
276 | Non Flame Proof Junction boxes |
277 | Non Flame Proof Lighting distribution boards/Terminal Box, 1 phase. |
278 | -Do- but 3 phases. |
279 | Flame Proof/ Increased Safety Lighting distribution boards 1 phase. |
280 | -Do- but 3 phases. |
281 | General cleaning of lighting fixtures of: - |
282 | LED fitting up to 2X18wW fitting of any type& size |
283 | Well glass LED fitting of any type & size up to 50 W |
284 | Post top lantern LED of any type & size up to 50 W. |
285 | LED Flood light of any type & size up to 80 W. |
286 | LED Flood light of any type & size up to 200 W. |
287 | LED Street light fitting of any type & size up to 75 w. |
288 | Flame proof / Increased Safety LED light fitting of any type & size |
289 | -Do- aviation light fixture. |
290 | Do- domestic lighting fixture up to 80 W. |
291 | FANS Erection, testing & comm. of ceiling/ exhaust / cabin fan for new installation |
292 | Removal of ceiling /exhaust/ Cabin fan. |
293 | Refixing of ceiling/ exhaust/ Cabin fan at old position |
294 | Over hauling of Ceiling/Exhaust fan / Cabin fan. |
295 | General Checking of Ceiling fan / Exhaust fan Viz. Locking Pin, Check nut, Locking nut, Suspension and Suspension Rod etc. |
296 | General cleaning of ceiling fan of any size alongwith its regulator. |
297 | CABLE TRAYS Installation of fabricated MS/ GI cable trays, including minor welding/ cutting work for: |
298 | Cable tray size up to 750 mm |
299 | Cable tray above 750mm |
300 | Replacement of cable trays of size 500/ 750mm width from ground floor to Prilling Tower Top or any other tall structure/ vessel, including replacement of supporting structure, refixing of existing earthing strips and clamping/ dressing of existing cables |
301 | Dismantling of fabricated MS/ GI cable trays, including minor welding/ cutting work for: |
302 | Cable tray size up to 750 mm |
303 | Cable tray above 750mm |
304 | FABRICATION Cast iron casting of sample piece without formation of pattern |
305 | Aluminium casting of sample piece without formation of pattern. |
306 | Fabrication & erection steel structural work of: |
307 | Large size |
308 | Extra small work with total weight per item not exceeding 0.5 kg including installation. |
309 | GI/ AL sheet work (fabrication & erection) |
310 | Cleaning and removal of coal/ ash dust/waste material from over head cable traysas per instructions an of Engineer-in-charge of the following sizes: - |
311 | Over head cable tray width up to 350 mm. |
312 | -Do- but width above 350 mm to 700 mm |
313 | -Do- but width above 700 mm to 1000 mm |
314 | -Do- but width above 1000 mm. |
315 | Cleaning of Cable Trenches in all plants of various sizes as per details given in scope of work. |
316 | Of size up to 1100mm width |
317 | Of size above 1100mm width |
318 | Of size up to 1100mm width but filled with sand |
319 | Of size above1100mm width but filled with sand |
320 | Of size up to 1100mm width but filled with ash |
321 | Of size above 1100mm width but filled with ash |
322 | Over hauling of LT Motors of following rating as per details in Scope of work: |
323 | Motor rating up to 1.1 KW |
324 | -Do- but above 1.1 KW up to 3.7 KW |
325 | -Do- but above 3.7 KW up to 11KW |
326 | -Do- but above 11 KW up to 37 KW |
327 | -Do- but above 37 KW up to 75 KW |
328 | -Do- but above 75 KW up to 125KW |
329 | -Do- but above 125KW up to 160KW |
330 | Replacement of LT Motors of following rating as per details in Scope of work: |
331 | Motor rating up to 1.1 KW |
332 | -Do- but above 1.1 KW up to 3.7 KW |
333 | -Do- but above 3.7 KW up to 11KW |
334 | -Do- but above 11 KW up to 37 KW |
335 | -Do- but above 37 KW up to 75 KW |
336 | -Do- but above 75 KW up to 125KW |
337 | -Do- but above 125KW up to 160KW |
338 | Recording of Energy Meter reading of all energy meters in T/Ship and CISF colony on quarterly basis. |
339 | Supply of Pedestal Fans on rental basis (per fan per day) during Annual Shut down |
340 | Upkeeping and cleaning of various Electrical Equipments In Ammonia plant on per month basis as per instructions of NFL"s supervisor & detailed as per scope. |
341 | Carrying of misc. tools for attending various jobs reported in Central shift on per month basis detailed as per scope. |
342 | Upkeeping and cleaning of various Electrical Equipments In CPP/GTG plant on per month basis as per instructions of NFL"s supervisor& detailed as per scope. |
343 | Upkeeping and cleaning of various Electrical Equipments In SGP plant on per month basis as per instructions of NFL"s supervisor& detailed as per scope. |
344 | Upkeeping and cleaning of various Electrical Equipments In Urea plant on per month basis as per instructions of NFL"s supervisor& detailed as per scope |
345 | Upkeeping and cleaning of various Electrical Equipments In O&U plant on per month basis as per instructions of NFL"s supervisor& detailed as per scope. |
346 | Upkeeping and cleaning of various Electrical Equipments In Workshop on per month basis as per instructions of NFL"s supervisor& detailed as per scope. |
347 | Upkeeping and cleaning of various Electrical Equipments In Telephone Exchange on per month basis as per instructions of NFL"s supervisor& detailed as per scope. |
348 | Carrying of misc. tools for attending various jobs reported In CPP shift on per month basis detailed as per scope. |
349 | Upkeeping and cleaning of various Electrical Equipments In Township on per month basis as per instructions of NFL"s supervisor& detailed as per scope. |
350 | Sweeping, mopping and cleaning of Electrical Substaions inAFCP on per month basis & detailed as per scope. |
351 | Sweeping, mopping and cleaning of Electrical Substaions in GTG, MRS, SGP, Workshop, Telephone Exchange on per month basis & detailed as per scope. |
352 | Sweeping, mopping and cleaning of Electrical Substaions in Urea, Bagging, DM, ETP, Agro, RW and Township on per month basis & detailed as per scope. |
353 | SUPPLY OF MATERIAL Supply of following material as per make, size & specifications given in scope of work: |
354 | Supply of GI stay wire set 7x8 SWG complete with accessories. |
355 | Supply of 6 SWG wire guard between neutrals of overhead line. |
356 | Supply of LT pin insulators including hardwares. |
357 | -Do- but shackle insulators. |
358 | Supply of earth station electrode only |
359 | Supply of 6/8 SWG GI wire |
360 | Supply of single spike GI Rod lightening arrestors |
361 | Supply of ms switch board with 3 mm thick sunmica sheet of size 10"x12" |
362 | -Do- but size 10"x8" |
363 | -Do- but size 9"x4" |
364 | -Do- but size 7"x4" |
365 | -Do- but size 4"x4" |
366 | Supply of 3mm thick Sunmica Sheet of size 11"x13" |
367 | -Do- but of size 9"x11" |
368 | -Do- but of size 10"x5" |
369 | -Do- but of size 8"x5" |
370 | -Do- but of size 5"x5"/ ROUND SHEET |
371 | Supply of wooden board of size 8"x10"/10"x12" |
372 | 7"X4" |
373 | 4"X4"/ Round Block. |
374 | SUPPLY OF MANPOWER Assistance in execution of intermittent electrical jobs during short shutdowns / onforeseen breakdowns / Annual turn around etc detailed as per scope of work. |
375 | Skilled worker (Normal working time- 8 hrs per day) |
376 | Semiskilled Worker (Normal working time- 8 hrs per day) |
377 | Unskilled Worker (Normal working time- 8 hrs per day) |
378 | Skilled worker (over time after 8hrs normal duty) |
379 | Semiskilled worker (over time after 8hrs normal duty) |
380 | Unskilled worker (over time after 8hrs normal duty) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail