Tender For Miscellaneous Electrical Jobs On Arc Basis In Factory And Township At Nfl Bathinda, bathinda-Punjab

National Fertilizers Limited-NFL has published Tender For Miscellaneous Electrical Jobs On Arc Basis In Factory And Township At Nfl Bathinda. Submission Date for this Tender is 18-04-2024. Man Power Supply Tenders in bathinda Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42499184
Corrigendum : Tender For Miscellaneous Electrical Jobs On Arc Basis In Factory And Township At Nfl Bathinda
Open Tender
Indian
Punjab
bathinda
18-04-2024

Tender Details

Miscellaneous Electrical Jobs On Arc Basis In Factory And Township At Nfl Bathinda

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Mar-2024 duedateextension1 Date 08-04-2024
2 08-Apr-2024 duedateextension2 Date 18-04-2024

Key Value

Document Fees
INR 1000 /-
EMD
INR 100000.0 /-
Tender Value
INR 2.49 Crore /-

BOQ Items

Name of Work: Miscellaneous Electrical jobs on ARC basis in factory and Township at NFL Bathinda.
Sl. No. Item Description
1Laying of 11/3.3 KV PVC/ XLPE/ PILC cable in trays, structures, pipes, and trenches etc. Of any size.
2Laying of LT PVC/ XLPE cables in trays, structures, pipes, trenches etc. of following sizes:
3Cable up to & including 3/4x25mm2,Control cables & Telephone Cables of all sizes with clamping etc.
4-Do- but without clamping
5Same as 2.00 but above 3/4x25mm2 & upto3/3.5x70mm2 with clamping etc.
6-Do- but without clamping etc.
7Same as 2.00 but above 3/3.5x70mm2 & upto 3/3.5x185mm2 with clamping etc.
8-Do- but without clamping etc.
9Same as 2.00 but above 3/3.5x185mm2 & upto3/3.5x400mm2 with clamping.
10-Do- but without clamping etc.
11Laying of 11/3.3 KV PVC/ PILC/ XLPE armoured power cable under the ground including supply of bricks and sand.
12Making of straight through joint of 11/ 3.3 KV PVC/ PILC/ XLPE armoured power cable of any size with Heat Shrinkable Jointing Kit
13Making of End Termination Joint (INDOOR) of 11/ 3.3 KV PVC/ PILC/ XLPE armoured power cable of any size with Heat Shrinkable Jointing Kit
14Making of straight through joint of LT armoured Power Cable of size 120 Sq.mm to 240 Sq.mm with Heat Shrinkable Jointing Kit.
15Laying of 1.1 KV PVC/ XLPE armoured power cable under the ground including supply of bricks and sand if required.
16Cable up to & including 3/4x25mm2,Telephone cable/control cable of any size.
17-Do- but successive cable.
18Above 3/3.5x25 mm2 to & including 3/3.5x70mm2
19-Do- but successive cable.
20Above 3/3.5x70 mm2 to & including 3/3.5x185mm2
21-Do- but successive cable.
22Above 3/3.5x185 mm2 to & including 3/3.5x400mm2
23-Do- but successive cable.
24Removing of 1.1KV/3.3KV/11KV PVC/PILC/XLPE underground cable of Size:
25Up to & including 3/3.5x70mm2, Control Cable/ Telephone cable of any size
26-Do- but successive cables.
27All sizes Above 3/3.5x70mm2
28-Do- but successive cables.
29Removing of 1.1KV/3.3KV/11KV PVC/PILC/XLPEcable from trenchs,tray,pipes,or structure.
30Cables up to & including 3/4x70mm2, Control / Telephone cable of any size
31Cables of all sizes above 3/3.5x70mm2
32Removing of 1.1KV/ 3.3KV/ 11KV underground cable and laying of new or existing cable in its place including supply of bricks and sand if required
33Cable up to & including 3/3.5x70mm2, Control / Telephone cable of any size
34-Do- but successive cables.
35Cables of all sizes Above 3/3.5x70mm2
36-Do- but successive cables.
37Pulling of cable in trench / pipe/ tray etc.to bring out margin at the end for its retermination:-
38Pulling up to length of 25 MR for cable size up to 3/3.5x70mm2, Control Cable/ Telephone Cable of any size.
39Pulling up to length of 25 MR for cable size above 3.5x70mm2 & up to 3/3.5x185mm2.
40Do- but for cable size above 3x3.5 x185mm2 and up to 3/3.5x400mm2.
41Pulling up to a length of 50 M for cable size up to 3.5x70mm2
42Pulling up to a length of 50 M for cable size above 3.5x70mm2 & up to 3.5x185mm2
43Pulling up to a length of 50 M for cable size above 3.5x185mm2 & up to 3.5x400mm2
44Pulling up to a length of 150 M for cable size up to 3.5x70mm2
45Pulling up to a length of 150 M for cable size above 3.5x70mm2 & up to 3.5x185mm2
46Pulling up to a length of 150 M for cable size above 3.5x185mm2 & up to 3.5x400mm2
47Tracing of cables armoured/ unarmoured, power/ control/ telephone, HT/LT of following sizes laid on vertical and horizontal cable trays up to length of 50 meters or part thereof
48Cables up to size of 3.5x70 mm2 and control cable up to 24 cores/Telephone cable up to 100 pairs
49Cables above 3.5x70mm 2 and up to 3.5x185 mm2 / Telephone Cable above 100 Pairs.
50Cables above 3.5x185 mm2 and up to 3.5x400 mm2
51MCB Erection, Testing and Commissioning of following sizes of lighting DBs/ MCB boxes
523 phase lighting DB of any number of outlets
53Single phase lighting DB
54MCB box with 3 phase MCB/3 phase power plug
55MCB box with 2 pole MCB
56MCB box with single pole MCB/single phase power plug
57Removal of following lighting DBs/ MCB boxes etc.
583 phase lighting DB of any number of outlets
59Single phase lighting DB
60MCB box with 3 phase MCB/3 phase power plug
61MCB box with 2 pole MCB
62MCB box with single pole MCB/single phase power plug
63Replacement of single/ double/ triple pole MCB/ Plug sockets as under:
64Single pole MCB/ Single phase power plug
65Double pole MCB
66Triple/four pole MCB/3 phase plug socket
673 phase lighting DB of any number of outlets
68MCB box with single pole MCB/power plug
69Writing of Identification name/ number on electrical equipments with red/white colour paint of size
70i) Letter up to and including 1" height
71ii) Letter above 1" but up to and including 2"
72iii) Letter above 2" but up to and including 4"
73iv) Letter above 4" but up to and including 8"
74Painting of any surface of Electrical equipments.(One coat of Primer & two coats of finished enameled synthetic paint)
75Transportation of material/ equipment from one plant to another or from main stores to any plant / electrical workshop excluding supply of any material or transport.
76HT/LT Motors up to 3.7 KW rating.
77-Do- but above 3.7 & up to 11 KW rating.
78-Do- but above 11 KW & up to 37 KW rating.
79-Do- but above 37 KW & up to 75 KW rating.
80-Do- but above 75 KW & up to 125 KW rating.
81-Do- but above 125 KW & up to 220 KW rating.
82-Do- but above 220 KW & up to 480 KW rating.
83-Do- but above 480 KW & up to 990 KW rating.
84Any material weighing more than 100 Kgs. But up to 250 Kgs.
85Any material weighing more than 250 Kgs.
86WORKSHOP Making formers of wood of different sizes for making coils for motors
87MRS & CPP SWITCHYARD Cleaning including uprooting of wild growth grass/rank vegetation/ bushes from 132 KV Switch Yard as per instructions of Engineer-in-charge of the following areas:
88In MRS approx. area 14500 Sq. Meter.
89In CPP approx. area 1900 Sq. Meter.
90Excavation of pebbles including uprooting of vegetation, bushes, washing of pebbles, stacking of serviceable pebbles after washing, disposable of unserviceable pebbles, malba, waste materials from transformer bays, spreading of serviceable pebbles and levelling
91In Ammonia Plant approx. pebbled area 26.5 Sq. Meter.
92In Ammonia Plant approx. pebbled area 31Sq. Meter.
93In Urea Plant approx. pebbled area 26.5 Sq. Meter.
94In Urea Plant approx. pebbled area 31 Sq. Meter.
95In DM Plant approx. pebbled area 26 Sq. Meter.
96In SGP approx. pebbled area 21 Sq. Meter.
97In CPP approx. pebbled area 43 Sq. Meter.
98In CHP approx. pebbled area 26.5 Sq. Meter.
99In RWFP approx. pebbled area 26.5 Sq. Meter.
100In Auxiliary Sub Station approx. pebbled area 45 Sq. Meter.
101In Ammonia Plant DG Set Yard pebbled area 136.32 Sq. Mr.
102In Ammonia Plant 6.3 MVA T/F Yard pebbled area 80.64 Sq. Mr.
103In Ammonia Plant 2 MVA T/F Yard pebbled area 148 Sq. Mr.
104TELEPHONE Erection Testing and Commissioning of Telephone DBs of following sizes
105Telephone DB up to 10 pairs
106Telephone DB above 10 pairs and up to 50 pairs
107Telephone DB above 50 pairs
108Dismantling of telephone DBs of following sizes
109Telephone DB up to 10 pairs
110Telephone DB above 10 pairs and up to 50 pairs
111Telephone DB above 50 pairs
112Replacement of telephone DBs of following sizes
113Telephone DB up to 10 pairs
114Telephone DB above 10 pairs and up to 50 pairs
115Telephone DB above 50 pairs
116Laying, termination & comm.Of telephone cables in existing conduit/ batten/ casing capping up to 5 pairs. Dismantling & relaying if required also included.
117Replacement of telephone socket / plug top/ ceiling rose etc.
118Erection & commissioning of telephone socket / ceiling rose on new switch board
119General maintenance including checking of incoming/ outgoing cables/ wires connections & proper sealing of telephone DBs of size:
120Up to 10 pairs.
121Above 10 pairs up to 50 pairs.
122Above 50 pairs up to 200 pairs.
123Above 200 pairs.
124OVERHEAD LINES Installation of single ACSR conductor squirrel/ panther/ ferret/ dog on existing poles including binding, stringing etc. per span of 60 MR maximum.
125Installation of GI stay wire set 7x8 SWG complete with accessories.
126Adjustment/ Repair of existing stay wire
127Installation of 6 SWG wire guard between neutrals of overhead line.
128Erection of LT pin insulators on existing cross arms including hardwares.
129Erection of LT shackle insulators on existing cross arms including hardwares.
130Stringing of single span single ACSR conductor squirrel/ panther/ ferret/ dog or shield/ guard wire between two poles of LT/ HT overhead line (max. Span length 60m)
131Checking of connection of PG clamps/ binding wire on LT/HT overhead line.
132Mtc. Of Double Circuit Towers of 132KV Overhead Line from CPP to MRS as per Scope of Work
133Mtc. Of Single Circuit Tower/ Gantries of 132KV Overhead Line from CPP to MRS as per Scope of Work
134Replacement of Jumpers of any size on LT/HT overhead line incl. Cleaning of Insulators
135Checking & Tightening of Guard wires.
136Replacement of overhead line ACSR conductor of any size & type per conductor per span of 60 M max.
137Fabrication of steel cross arms and its erection on existing poles including the accessories, hardwares etc.
138Replacement of GI stay wire /stay wire insulator.
139Dismantling of 3 phase LT overhead line of panther / ferret / squirrel/ dog ACSR conductor including accessories between two poles having a span length of max 60 MR.
140-Do-but 11 KV HT overhead line (span of max 60 MR)
141Dismantling of complete stay wire set from RCC/ Steel Tubular Poles.
142Dismantling of overhead line ACSR conductor including hardware per conductor /span of 60 MR max.
143Erection of RCC / Steel Tubular Pole/ Lighting Mast etc.
144Up to height of 12 ft.
145Above 12 ft. & up to height of 24 ft.
146Above 24 ft.
147Installation of temporary Pole of any size and removing there after.
148Erection/ Dismantling/ Replacement of Steel Tubular Pole of height up to 12 feet by cutting/ welding/ clamping
149Dismantling of fabricated Steel/ RCC / Steel Tubular Pole/ Lighting Mast.
150Up to height of 12 ft.
151Above 12 ft. & up to height of 24 ft.
152Above 24 ft.
153EARTHING Installation, testing & commissioning of earthing station
154Maintenance of earthing station including supply of salt (if reqd.) for reconditioning and measuring / recording of earth resistance value.
155Erection of earth electrode only in the existing earth pit
156Laying of GI / AL EARTH STRIP in ground or on tray, structure etc of following sizes
157Up to 150mm2
158Above 150mm2
159Refixing of existing earth strip.
160Dismantling of GI / AL EARTHING of any size from ground or structure, tray etc.
161Laying/ Termination/ Dismantling of 6/8 SWG GI/AL wire on existing RCC poles or other structure/ wall/ under ground etc. including supply of hardwares like bolts, nuts, clamps etc. As reqd
162Installation of single spike GI Rod lightening arrestors over cooling tower or any tall structure
163Dismantling of single spike GI rod lightening Arrester over Cooling Tower or any tall Structure.
164SWITCH FUSE UNITS/CONTROL GEARS Installation/ Dismantling OF Push button station/ motor starter/ TPN/ SPN or Change Over switches/ Flame Proof outlets:
165Up to 125 amps.
166Above 125 Amps.
167Dismantling / Erection / Replacement of MS/ CI/ PVC junction box/ Telephone DB of any size in / from wall or RCC ceiling / column etc.:
168Erection
169Dismantling
170Replacement/ Refixing
171Removal of MS/ CI box/ wooden board from masonry wall or RCC column
172Glanding or reglanding of cables with single / double compression type cable glands of size up to 1" dia.
173-Do- but of size above 1" dia & up to 2" dia.
174-Do- but of size above 2" dia.
175DOMESTIC WIRING Laying, Termination & Commissioning of PVC insulated flexible Copper wire single core 6mm2/ Flexible cable of size up to 2X6mm2/ 3x1.5mm2 flexible Cable on existing wooden batten/ PVC Casing capping/ Conduit pipe including supply of all the required material
176Laying, Termination & Commissioning of PVC insulated flexible Copper wire single core 6mm2/ Flexible cable of size up to 2X6mm2/ 3x1.5mm2 in PVC Casing capping/ Conduit pipe including supply of all the required material as specified in Scope of Work.
177With supply of PVC Casing capping/ Conduit Pipe of size up to 1"
178With supply of PVC Casing capping/ Conduit Pipe above 1" up to 2"
179Replacement of worn out wooden batten/ PVC or MS conduit/ PVC casing capping with PVC casing capping/ conduit pipe of size 1" including supply of all material except wire/ cable.
180-Do- but of size above 1" and up to 2"
181Installation of MS switch board with 3 mm thick sunmica sheet of size:
18210"X12"
18310"X8"
1849"X4"
1857"X4"
1864"X4"
187Installation of Wooden boards of following sizes
1888"X10" & above
1897"X4"
1904"X4"/ Round Block.
191Dismantling of single core Al/ Cu conductor cable of size up to 6mm2 or 3 core flexible cable from wooden batten/ PVC conduit/ PVC casing capping
192-Do- but relaying as well.
193Replacement of 14 / 16 SWG earth wire in conduit or on batten.
194Wiring for Light/ Fan/ Exhaust fan/ 5 Amp Socket point in recessed conduit with PVC insulated copper conductor of size 1.5 Sq. mm. including supply of all material for following sizes:
195Short point
196Medium point
197Long point
198Circuit wiring in recessed conduit with following size of conductor including supply of all material
199With 1.5 Sq. mm. Cu. conductor.
200With 2.5 Sq. mm. Cu. conductor.
201With 4 Sq. mm. Cu. conductor.
202With 6 Sq. mm. Cu. conductor.
203Circuit wiring in exiting conduit with 1.5 Sq. mm. Cu conductor with supply of material:
204- Do - but 2.5 Sq. mm.
205- Do - but 4 Sq. mm.
206- Do - but 6 Sq. mm.
207Wiring for Twin control Light point in PVC Casing capping/ Recessed PVC Conduit with copper conductor of size 1.5 Sq. mm. including supply of all material for following sizes:
208Short point.
209Medium point
210Long point.
211Wiring for 15 Amp Socket point in PVC Casing capping/ PVC Recessed conduit with copper conductor of size 4 Sq. mm. including supply of all material for short point:
212-Do- but with 6 Sq. mm.Cu. conductor.
213TOWNSHIP Attending of no light complaints of following houses/ buildings in township/ CISF colony:
214A/B/C/D type house/ Residential Rooms of Expert Hostel & Sub-feeders of Public Building in normal working hours.
215A/B/C/D type house/ Residential Rooms of Expert Hostel & Sub-feeders of Public Building during odd hours.
216Installation and removal of temporary lights/ extension boards as required in township.
217Temporary installation of Lighting Circuit having max. 30 lamps up to 200W ratings in parallel and removing the same after completion of job as per scope of work.
218Temporary installation of Main Lighting/ Power Distribution Board and removing the same after completion of job as per scope of work.
219Temporary installation of Flood Lights of any rating including its control gears on Poles and removing after completion of job.
220Replacement of 5 or 15 amp domestic /industrial / switch /socket /plug top /lamp holder /kit kat /bell push /buzzer /round block /fuse /fan capacitor /regulator/repair of fan regulator and connections and or disconnection of electrical appliance including attending of minor faults.
221Erection & commissioning of 5 /15 Amp switch /socket /fan regulator on a new switchboard.
222Refixing of domestic light fitting of any type
223Maintenance of glow sign boards installed at a height of 6 M approx.
224Maintenance of pole mounting box.
225Installation /removal / replacement of single / 3 phase energy meter.
226Installation
227Removal
228Replacement
229General maintenance of single / three phase meter boards of residential units in township & CISF colony/ public buildings.
230TEMPORARY CONNECTION Temporary laying of armoured/ unarmoured cables of following sizes & lengths for connecting Hand Lamp / Flood Light / Extension Board / Welding Set etc. of any type & size & its removal, if reqd; after completion of job.
231Flexible cable up to 4x2.5mm2 & up to 15 MR. Length.
232-Do- but above 15 MR & up to 50 MR Length.
233-Do- but above 50 M and up to 100 MR. Length.
234Armoured Cable of size up to & including 4 x25mm2 & length up to 100 M.
235-Do- but length above 100 M & up to 300 MR.
236Armoured Cable of size above 4x25 mm2 but up to 3.5x70mm2 & length up to 100 M.
237-Do- but length above 100 M & up to 300 MR
238Armoured Cable of size above 3.5x70 mm2 but up to 3.5x185mm2 & length up to 100 M.
239-Do- but length above 100 M & up to 300 MR.
240Armoured Cable of size above 3.5x185mm2 & length up to 100 MR.
241-Do- but length above 100 M & up to 300 MR.
242LIGHTING Erection, testing & comm. of LED street light fixture up to 2x18 W on existing poles including supply of B-class GI pipe bracket 1 MR long.
243Erection, testing & comm. of following type of lighting fixture including control gear:
244LED fitting up to 2X18wW fitting of any type& size.
245Well glass LED fitting of any type & size up to 50 W
246Post top lantern LED of any type & size up to 50 W.
247LED Flood light of any type & size up to 80 W.
248LED Flood light of any type & size up to 200 W.
249LED Street light fitting of any type & size up to 75 w.
250Flame proof / Increased Safety LED light fitting of any type & size
251Aviation light fitting of any type & size
252Assembly of light fitting including wiring of any type & size
253Replacement of tube rod/lamp /glass/ wire guard gasket/ lamp holder etc
254Removal of fault/ replacement of any single accessory, in lighting fixture any type and size up to 200W as stated in item 69.00
255-Do- but in street light fixture.
256-Do- but in increased safety / flameproof lighting fixture.
257-Do- but in aviation lighting fixture.
258Removal of fault/replacement of 2 or more accessories in lighting fixture of any type &size up to 200W as stated in 69.00
259-Do- but in street light fixture.
260-Do- but in increased safety /flameproof lighting fixture.
261-Do- but in aviation lighting fixture.
262Removal of fault/ replacement of any single accessory in lighting fixture of any type &size above 200 was stated in item 69.00
263-Do- but in street light fixture.
264-Do- but in increased safety flameproof lighting fixture.
265Same as item 70.00 but removal of fault /replacement of 2 or more accessories.
266-Do- but in street light fixture.
267-Do- but in increased safety flameproof lighting fixture.
268Replacement of gen. lighting fixture of any size or type up to 200 w.
269-Do- butflood light fixture of any size & type.
270-Do- but increased safety/Flameproof light fixture.
271Dismantling of LED light fitting of upto 50W
272Dismantling of any LED fitting above 50W to upto100 W.
273Dismantling of flood light fitting above 100 W.
274Dismantling of aviation light fitting.
275Maintenance of lighting board/junction boxes/terminal box etc.
276Non Flame Proof Junction boxes
277Non Flame Proof Lighting distribution boards/Terminal Box, 1 phase.
278-Do- but 3 phases.
279Flame Proof/ Increased Safety Lighting distribution boards 1 phase.
280-Do- but 3 phases.
281General cleaning of lighting fixtures of: -
282LED fitting up to 2X18wW fitting of any type& size
283Well glass LED fitting of any type & size up to 50 W
284Post top lantern LED of any type & size up to 50 W.
285LED Flood light of any type & size up to 80 W.
286LED Flood light of any type & size up to 200 W.
287LED Street light fitting of any type & size up to 75 w.
288Flame proof / Increased Safety LED light fitting of any type & size
289-Do- aviation light fixture.
290Do- domestic lighting fixture up to 80 W.
291FANS Erection, testing & comm. of ceiling/ exhaust / cabin fan for new installation
292Removal of ceiling /exhaust/ Cabin fan.
293Refixing of ceiling/ exhaust/ Cabin fan at old position
294Over hauling of Ceiling/Exhaust fan / Cabin fan.
295General Checking of Ceiling fan / Exhaust fan Viz. Locking Pin, Check nut, Locking nut, Suspension and Suspension Rod etc.
296General cleaning of ceiling fan of any size alongwith its regulator.
297CABLE TRAYS Installation of fabricated MS/ GI cable trays, including minor welding/ cutting work for:
298Cable tray size up to 750 mm
299Cable tray above 750mm
300Replacement of cable trays of size 500/ 750mm width from ground floor to Prilling Tower Top or any other tall structure/ vessel, including replacement of supporting structure, refixing of existing earthing strips and clamping/ dressing of existing cables
301Dismantling of fabricated MS/ GI cable trays, including minor welding/ cutting work for:
302Cable tray size up to 750 mm
303Cable tray above 750mm
304FABRICATION Cast iron casting of sample piece without formation of pattern
305Aluminium casting of sample piece without formation of pattern.
306Fabrication & erection steel structural work of:
307Large size
308Extra small work with total weight per item not exceeding 0.5 kg including installation.
309GI/ AL sheet work (fabrication & erection)
310Cleaning and removal of coal/ ash dust/waste material from over head cable traysas per instructions an of Engineer-in-charge of the following sizes: -
311Over head cable tray width up to 350 mm.
312-Do- but width above 350 mm to 700 mm
313-Do- but width above 700 mm to 1000 mm
314-Do- but width above 1000 mm.
315Cleaning of Cable Trenches in all plants of various sizes as per details given in scope of work.
316Of size up to 1100mm width
317Of size above 1100mm width
318Of size up to 1100mm width but filled with sand
319Of size above1100mm width but filled with sand
320Of size up to 1100mm width but filled with ash
321Of size above 1100mm width but filled with ash
322Over hauling of LT Motors of following rating as per details in Scope of work:
323Motor rating up to 1.1 KW
324-Do- but above 1.1 KW up to 3.7 KW
325-Do- but above 3.7 KW up to 11KW
326-Do- but above 11 KW up to 37 KW
327-Do- but above 37 KW up to 75 KW
328-Do- but above 75 KW up to 125KW
329-Do- but above 125KW up to 160KW
330Replacement of LT Motors of following rating as per details in Scope of work:
331Motor rating up to 1.1 KW
332-Do- but above 1.1 KW up to 3.7 KW
333-Do- but above 3.7 KW up to 11KW
334-Do- but above 11 KW up to 37 KW
335-Do- but above 37 KW up to 75 KW
336-Do- but above 75 KW up to 125KW
337-Do- but above 125KW up to 160KW
338Recording of Energy Meter reading of all energy meters in T/Ship and CISF colony on quarterly basis.
339Supply of Pedestal Fans on rental basis (per fan per day) during Annual Shut down
340Upkeeping and cleaning of various Electrical Equipments In Ammonia plant on per month basis as per instructions of NFL"s supervisor & detailed as per scope.
341Carrying of misc. tools for attending various jobs reported in Central shift on per month basis detailed as per scope.
342Upkeeping and cleaning of various Electrical Equipments In CPP/GTG plant on per month basis as per instructions of NFL"s supervisor& detailed as per scope.
343Upkeeping and cleaning of various Electrical Equipments In SGP plant on per month basis as per instructions of NFL"s supervisor& detailed as per scope.
344Upkeeping and cleaning of various Electrical Equipments In Urea plant on per month basis as per instructions of NFL"s supervisor& detailed as per scope
345Upkeeping and cleaning of various Electrical Equipments In O&U plant on per month basis as per instructions of NFL"s supervisor& detailed as per scope.
346Upkeeping and cleaning of various Electrical Equipments In Workshop on per month basis as per instructions of NFL"s supervisor& detailed as per scope.
347Upkeeping and cleaning of various Electrical Equipments In Telephone Exchange on per month basis as per instructions of NFL"s supervisor& detailed as per scope.
348Carrying of misc. tools for attending various jobs reported In CPP shift on per month basis detailed as per scope.
349Upkeeping and cleaning of various Electrical Equipments In Township on per month basis as per instructions of NFL"s supervisor& detailed as per scope.
350Sweeping, mopping and cleaning of Electrical Substaions inAFCP on per month basis & detailed as per scope.
351Sweeping, mopping and cleaning of Electrical Substaions in GTG, MRS, SGP, Workshop, Telephone Exchange on per month basis & detailed as per scope.
352Sweeping, mopping and cleaning of Electrical Substaions in Urea, Bagging, DM, ETP, Agro, RW and Township on per month basis & detailed as per scope.
353SUPPLY OF MATERIAL Supply of following material as per make, size & specifications given in scope of work:
354Supply of GI stay wire set 7x8 SWG complete with accessories.
355Supply of 6 SWG wire guard between neutrals of overhead line.
356Supply of LT pin insulators including hardwares.
357-Do- but shackle insulators.
358Supply of earth station electrode only
359Supply of 6/8 SWG GI wire
360Supply of single spike GI Rod lightening arrestors
361Supply of ms switch board with 3 mm thick sunmica sheet of size 10"x12"
362-Do- but size 10"x8"
363-Do- but size 9"x4"
364-Do- but size 7"x4"
365-Do- but size 4"x4"
366Supply of 3mm thick Sunmica Sheet of size 11"x13"
367-Do- but of size 9"x11"
368-Do- but of size 10"x5"
369-Do- but of size 8"x5"
370-Do- but of size 5"x5"/ ROUND SHEET
371Supply of wooden board of size 8"x10"/10"x12"
3727"X4"
3734"X4"/ Round Block.
374SUPPLY OF MANPOWER Assistance in execution of intermittent electrical jobs during short shutdowns / onforeseen breakdowns / Annual turn around etc detailed as per scope of work.
375Skilled worker (Normal working time- 8 hrs per day)
376Semiskilled Worker (Normal working time- 8 hrs per day)
377Unskilled Worker (Normal working time- 8 hrs per day)
378Skilled worker (over time after 8hrs normal duty)
379Semiskilled worker (over time after 8hrs normal duty)
380Unskilled worker (over time after 8hrs normal duty)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail