Providing Electrical Installation In 10(Ten) Bedded Primary Health Centre (Phc) Building (Single Storied) Including 10(Ten) Nos. Staff Quarters (Type-I Quarter-4 Units (One Block-Twin Double Storey), Type-Ii Quarter-4 Units (One Block- Twin Double Storey), kumarghat-Tripura

Public Works Department-PWD has published Providing Electrical Installation In 10(Ten) Bedded Primary Health Centre (Phc) Building (Single Storied) Including 10(Ten) Nos. Staff Quarters (Type-I Quarter-4 Units (One Block-Twin Double Storey), Type-Ii Quarter-4 Units (One Block- Twin Double Storey). Submission Date for this Tender is 12-03-2024. Electrical Maintenance Tenders in kumarghat Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

42499046
Providing Electrical Installation In 10(Ten) Bedded Primary Health Centre (Phc) Building (Single Storied) Including 10(Ten) Nos. Staff Quarters (Type-I Quarter-4 Units (One Block-Twin Double Storey), Type-Ii Quarter-4 Units (One Block- Twin Double Storey)
Open Tender
Indian
Tripura
kumarghat
12-03-2024

Tender Details

Providing Electrical Installation In 10 ( Ten ) Bedded Primary Health Centre ( Phc ) Building ( Single Storied ) Including 10 ( Ten ) Nos. Staff Quarters ( Type-I Quarter-4 Units ( One Block-Twin Double Storey ) , Type-Ii Quarter-4 Units ( One Block- Twin Double Storey ) , And Type-Iii Quarter-2 Units ( One Block Twin -Single Storey ) ) , Kitchen, Morgue, Garage & Generator With Driver Room Building In Place Of Existing Uptakhali Phc, North Tripura. / / 10 ( Ten ) Nos. Staff Quarters ( Type-I Quarter-4 Units ( One Block-Twin Double Storey ) , Type-Ii Quarter-4 Units ( One Block- Twin Double Storey ) , And Type-Iii Quarter-2 Units ( One Block Twin -Single Storey ) .

Key Value

Document Fees
INR 1000 /-
EMD
INR 11233.0 /-
Tender Value
INR 5.61 Lakhs /-

BOQ Items

Name of Work:- Providing E.I in 10(Ten) bedded Primary Health Centre (PHC) building (Single storied) including 10(Ten) nos. staff Quarters (Type-I quarter-4 units (One block-twin double storey), Type-II quarter-4 units (One block- twin double storey), and Type-III quarter-2 units (One block twin -single storey)), Kitchen, Morgue, Garage & Generator with Driver room building in place of existing Uptakhali PHC, North Tripura.// 10(Ten) nos. staff Quarters (Type-I quarter-4 units (One block-twin double storey), Type-II quarter-4 units (One block- twin double storey), and Type-III quarter-2 units (One block twin -single storey).
Sl. No. Item Description
1Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with wooden switch board with bakelite cover and piano type switch including connection etc as required:-(As per TSR 2021,sl no.101)
2Short Point :-
3Medium Point :-
4Long Point :-
5Providing and fixing of 3 pin 5/6 amps plug point withpianotype 5/6ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:-(As per TSR 2021,sl no.103)
6Providing and fixing of 3/6 pin15/16 amps plug point withpianotype 15/16ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:-(As per TSR 2021,sl no.104)
7Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:- (As per TSR 2021,sl no.305)
82 X 1.5 sq mm
92 X 2.5 sq mm
102 X 4 sq mm
11Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required.(As per TSR 2021,sl no.701)
12Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required.(As per TSR 2021,sl no.702)
13Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. (As per TSR 2021,sl no.706)
14Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required.(As per TSR 2021,sl no.710)
15Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) : -(As per TSR 2021,sl no.802)
16Supplying and fixing of the following electrical accessories including necessary connection etc. as required.(As per TSR 2021,sl no.604)
17Electronic 5 step fan regulator
18Ding dong call bell
19Supplying & installation of 225/230 mm sweep metalic body exhaust fan including connection etc as required:-(As per TSR 2021,sl no.816)
20Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:-(As per TSR 2021,sl no.821)
21Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):-(As per TSR 2021,sl no.1001)
22Box type single FTL fittings of CRCA steel sheet housing complete with 36/40 W FTL,electronic ballast and high quality reflector cover : -
23Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-(As per TSR 2021,sl no.1102)
2445 watt LED street light fixture with integral driver and secondary lens (IP 66):-
25Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required(As per TSR 2021,sl no.1301)
263 core 4 Sq mm
27Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : -(As per TSR 2021,sl no.1405)
281 sqmm - 4 sqmm Cable:-
29Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:-(As per TSR 2021,sl no.1501)
3040 mm dia
31Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:-(As per TSR 2021,sl no.1202)
3232 amps 240 volts DP main switch (rewireable):-
33Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required.(As per TSR 2021,sl no.1208)
34(2+6) / 8way SPN MCB DB (single door):-
352 way SPN MCB DB (single door):-
36Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required:-(As per TSR 2021,sl no.1215)
376 to 32 amps SP MCB:-
386 to 32 amps DP MCB:-
39Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required:-(As per TSR 2021,sl no.1502)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail