Housing Urban and Rular Development Government Departments Closing in 0 days TDR #42489657

Tender For Construction Of Central Administrative Building At Bhatkuli Dist. Amravati (Including Electrical Works)

Issued by Government Departments · bhatkuli, Maharashtra
Tender Value
28.71 Crore
Estimated cost
Bid Submission
14 Mar 2024
0 days left
EMD
14.36 Lakhs
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bhatkuli → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Central Administrative Building At Bhatkuli Dist. Amravati (Including Electrical Works)

BOQ

Name of Work: Construction of Administrative Building at Bhatkuli, Tq. Bhatkuli, Dist. Amravati (Civil + Electrical)
Sl. No. Item Description
1Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting including all lifts etc.complete.
2GROUND FLOOR
3Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
4GROUND FLOOR
5Excavation for foundation in Hard murum including removing the excavated material upto a distanceof50metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebedforthefoundationandnecessarybackfilling,ramming, wateringincludingshoringand struttingincluding all lifts etc.complete.
6GROUND FLOOR
7ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)bytreatingthe bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifospersquaremeterofsurfaceareacovering10yearsguaranteeon bond paper. Including all leads and lifts etc.complete.
8GROUND FLOOR
9ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)treatmentby treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos perOne Square Metre of vertical surface area covering 10 years guarantee on bond paper. Including all leads and lifts etc.complete.
10GROUND FLOOR
11Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosperOne Square Metre of surface area covering ten years guarantee on bond paper. Including all leads and lifts etc.complete.
12GROUND FLOOR
13Fillinginplinthandfloorswith approved excavatedmaterialin15cm.to20cm.Layers including watering and compacting including all leads and lifts etc.complete.
14GROUND FLOOR
15Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionincluding all leads and lifts etc.complete.
16GROUND FLOOR
17Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting including all leads and lifts etc.complete.
18GROUND FLOOR
19ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) including all leads and lifts etc.complete. With fine aggregate (Natural Sand)
20GROUND FLOOR
21ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/quartzite/gneissmetalforR.C.C.workinfoundationslike raft,strip foundations,grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water,Steel centering,formwork,coverblocks,laying/pumping,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) including all leads and lifts etc.complete. With fine aggregate (Natural Sand)
22GROUND FLOOR
23ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite /quartzite/gneissmetalforR.C.C.columnsasperdetaileddesignsanddrawingsoras directedincludingsteelcentering,formwork,coverblocks,laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smoothand even surface or roughening if special finish is to be providedand curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) including all leads and lifts etc.complete. With fine aggregate (Natural Sand)
24GROUND FLOOR
25FIRST FLOOR
26SECOND FLOOR
27TERRACE FLOOR
28ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-25oftrap/granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcementandstructuralsteel).withfullyautomaticmicroprocessorbasedPLCwith SCADAenabledreversibleDrumTypemixer/concreteBatchmixplant(Panmixer)including all leads and lifts etc.complete. With fine aggregate (Natural Sand)
29GROUND FLOOR
30FIRST FLOOR
31SECOND FLOOR
32TERRACE FLOOR
33ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-25oftrap/granite/ quartzite/ gneiss metal for R.C.C.slabs andlandingsasper detaileddesigns anddrawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) including all leads and lifts etc.complete. With fine aggregate (Natural Sand)
34GROUND FLOOR
35FIRST FLOOR
36SECOND FLOOR
37TERRACE FLOOR
38Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting androughening the surface ifspecial finish is to be provided and curing complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLCwithSCADA enabledreversibleDrum Typemixer/concreteBatchmixplant(Panmixer) including all leads and lifts etc.complete.Withfineaggregate (Natural Sand)
39GROUND FLOOR
40FIRST FLOOR
41SECOND FLOOR
42TERRACE FLOOR
43ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-25oftrap/quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawingsorasdirectedincludingsteelcentering,plywood/steelformwork,steelprops, laying/pumping,compaction,finishing unevenandhoneycombedsurface withC.M.1:3of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer) including all leads and lifts etc.complete. Withfineaggregate(Natural Sand)
44GROUND FLOOR
45FIRST FLOOR
46SECOND FLOOR
47ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-25oftrap/granite/ quartzite/gneissmetalforR.C.C.pardiofrequiredthicknessincludingsteelcentering, formwork, cover blocks, laying/pumping,compacting and roughening them if special finish istobeprovidedandcuringcomplete.(Excludingreinforcementandstructuralsteel).with fullyautomaticmicroprocessorbasedPLCwithSCADAenabledreversibleDrumType mixer/concreteBatchmixplant(Panmixer)including all leads and lifts etc.complete.Withfineaggregate(Natural Sand)
48GROUND FLOOR
49FIRST FLOOR
50SECOND FLOOR
51TERRACE FLOOR
52Providing andlaying Castinsitu/ReadyMixcement concrete M-15oftrap/ granite/quartzite/gneissmetalforcoping to plinthorparapet,mouldedorchamferedasper drawingorasdirectedincludingsteelcentering,plywood/steelformworkcompacting, rougheningthemifspecialfinishistobeprovided,finishingunevenandhoneycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin including all leads and lifts etc.complete. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand)
53GROUND FLOOR
54TERRACE FLOOR
55ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-20oftrap/granite/gneiss/quartzitemetalforR.C.C.finsofrequiredthicknessinpositionasshownonthe drawingsorasdirectedbyEngineer-in-chargeincludingsteelcentering,plywood/steel formwork,steelprops,laying/pumping,compaction,finishingunevenandhoneycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement,including coverblock)Newlylaidconcrete shallbe coveredby gunnybag, plastic, tarpaulin etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand)
56GROUND FLOOR
57FIRST FLOOR
58SECOND FLOOR
59Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required including all leads and lifts etc.complete.
60GROUND FLOOR
61FIRST FLOOR
62SECOND FLOOR
63TERRACE FLOOR
64Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding including all leads and lifts etc.complete.
65GROUND FLOOR
66ProvidingAutoclavedAeratedConcreteBlockmasonaryof conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
67GROUND FLOOR
68FIRST FLOOR
69SECOND FLOOR
70Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering including all leads and lifts etc.complete.
71GROUND FLOOR
72FIRST FLOOR
73SECOND FLOOR
74ProvidingAutoclavedAeratedConcreteBlockmasonaryofconforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech orequivalentinHalfbrickthickwallincludingstrikingjoints,rakingoutjointsand scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
75GROUND FLOOR
76FIRST FLOOR
77SECOND FLOOR
78Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete
79GROUND FLOOR
80FIRST FLOOR
81SECOND FLOOR
82TERRACE FLOOR
83ProvidingfirstclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:4includingscaffolding,rackingoutjointspointinginC.M.1:3andwateringin pillars of rectangular or square shape as shown on the drawing or as directed etc.complete.
84GROUND FLOOR
85FIRST FLOOR
86SECOND FLOOR
87Waterproofing Treatment to new terrace by using Polymeric Cementitious Membraneas approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall bepaid separately). Clean the entire surface thoroughly and over this prepared surface, applythree coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties with 10 Year Gurantee Bond:(1) Elongation % (ASTM D412-2016): @ 100%(2) Tensile Strength N/mm2 (ASTM D412-2016): 3.3 (3) Specific Gravity: 1.02 ± 0.02(4) Total Solids (ASTM D1644-2012): 43.98 (5) Hardness Shore A (ASTM D2240-2015): 82.Including all leads and lifts etc.complete.
88SECOND FLOOR
89TERRACE FLOOR
90Waterproofing Treatment to new Toilet/bathroom by using Polymeric Cementitious Membraneas approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall bepaid separately). Clean the entire surface thoroughly and over this prepared surface, applythree coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene-Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agentsas approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixingone 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of wall and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties with Gurantee 10 year on bond paper Bon:1) Elongation % (ASTM D412-2016): @ 100%2) Tensile Strength N/mm2 (ASTM D412-2016): 3.3 3) Specific Gravity: 1.02 ± 0.024) Total Solids (ASTM D1644-2012): 43.98 5) Hardness Shore A (ASTM D2240-2015): 82.Including all leads and lifts etc.complete.
91GROUND FLOOR
92FIRST FLOOR
93SECOND FLOOR
94Providing waterproof plaster in W.C. and bath20 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing(and filling joints of Nahani trap andany outlet by properly) including all leads and lifts etc.complete.
95GROUND FLOOR
96FIRST FLOOR
97SECOND FLOOR
98Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing including all leads and lifts etc.complete.
99GROUND FLOOR
100FIRST FLOOR
101SECOND FLOOR
102TERRACE FLOOR
103Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing including all leads and lifts etc.complete.
104GROUND FLOOR
105FIRST FLOOR
106SECOND FLOOR
107TERRACE FLOOR
108Providing sand faced plaster externally in cement mortar using approved screened sand, in all positionsincludingbasecoatof15mmthickincementmortar1:4usingwaterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoatroughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurfacebytakingoutgrainsandcuringforfourteendays scaffolding including all leads and lifts etc.complete.
109GROUND FLOOR
110FIRST FLOOR
111SECOND FLOOR
112TERRACE FLOOR
113ProvidingandapplyingTextureplasterwithfinishingwithtexturematerial ofapproved makein 3 to 4 millimeterthickness on previously plastered surface, including Plaster Groove 6mmthicknessorTapeGrooves35to45mmthicknessorasrequired,inallposition including preparing the surface, scaffolding etc. complete.
114GROUND FLOOR
115FIRST FLOOR
116SECOND FLOOR
117TERRACE FLOOR
118Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.Cmembersandbrickwork,ofapprovedqualityincludingfixing meshinpositionby necessary drilling in concrete /B.B.masonry and or tying by binding wire including all leads and lifts etc.complete.
119GROUND FLOOR
120FIRST FLOOR
121SECOND FLOOR
122TERRACE FLOOR
123Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curingincluding all leads and lifts etc.complete.
124GROUND FLOOR
125FIRST FLOOR
126SECOND FLOOR
127TERRACE FLOOR
128Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Rubyred / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning including all leads and lifts etc.complete.
129GROUND FLOOR
130FIRST FLOOR
131SECOND FLOOR
132Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade withfullmoulding and three grooved line forthetreadsonbedof1:4Cementmortarincludingfloatfilling jointswithneatcement slurry curing polishing and cleaning including all leads and lifts etc.complete.
133GROUND FLOOR
134FIRST FLOOR
135SECOND FLOOR
136Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement including all leads and lifts etc.complete. b) Both side polish
137GROUND FLOOR
138FIRST FLOOR
139SECOND FLOOR
140Providingandfixingmachinecutmirrorpolished18mm to20mm thicktelephoneblack granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges including all leads and lifts etc.complete. Both side polish
141GROUND FLOOR
142FIRST FLOOR
143SECOND FLOOR
144Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequiredwidthinplain/diamondpatternonbedof1:6C.M.including cementfloat, filling joints with neat cement slurry, curing, polishing and cleaningincluding all leads and lifts etc.complete.
145GROUND FLOOR
146SECOND FLOOR
147Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneatcementfloat,fillingjoints,curingandclearing including all leads and lifts etc.complete.
148GROUND FLOOR
149FIRST FLOOR
150SECOND FLOOR
151Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearingincluding all leads and lifts etc.complete.
152GROUND FLOOR
153FIRST FLOOR
154SECOND FLOOR
155TERRACE FLOOR
156Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning including all leads and lifts etc.complete.
157GROUND FLOOR
158FIRST FLOOR
159SECOND FLOOR
160Providingsillsofrequiredmaterial20mmto25mmthick,onabedofcementmortar1:4 includingcementfloat,fillingjointswithneatcementslurry,curing,polishing,moulding edges, cleaningincluding all leads and lifts etc.complete. a) Marble other than white makrana
161GROUND FLOOR
162Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing including all leads and lifts etc.complete.
163GROUND FLOOR
164FIRST FLOOR
165SECOND FLOOR
166Providingandlayingtelephoneblack/AmbaWhite/Cadburybrown/Rubyred/Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, including all leads and lifts etc.complete.
167GROUND FLOOR
168FIRST FLOOR
169SECOND FLOOR
170Providing, laying andfixing exterior grade fibrilling fibre reinforcement heavy duty designer cementconcrete tilesforFlooring ofapprovedcolour anddesign 22+/ -2mm thickbayer colourpigmentedasperIS..1237-1980havingcompressivestrengthmorethan500 Kilogram/sq.cmreaffirmedin2006,havingwerttransvrsestrenghthof3.5/mm2,water absorption less than 10 % abrasion / wear resistance less than 2 mm ,skid resistance more than25.0 (ASTM:E303) and no fading as per DIN - 51094 of size 300 x 300in plan / designed pattern on a bed of 1:4 cement mortar including cement float ,filling joints with neat cement slurry ,curing, polishing and cleaning etc. complete. For flooring.
171GROUND FLOOR
172Providing andLayingfactory madecolouredchamferededge Cementconcrete grasspaver blocks of required strength,thickness and size/shape, made by table vibratory method using PU mould,laidinrequiredcolourandpatternover50mmthickcompactedbedoffinefine aggregate (natural sand/crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) bedding layer through vibratory compaction by using plate vibrator,fillingthejointswithfineaggregate(naturalsand/crushedsandVSIgradefinely washedetc.)andcuttingofpaverblocksasperrequiredsizeandpattern,finishingand sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer spsecifications and direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design and pattern.
173GROUND FLOOR
174Providing andapplying Twocoats ofwall care Putty onplastered surface andCeiling and Walls to prepare surface even and smooth of approved make, including all leads and lifts etc.complete.
175GROUND FLOOR
176FIRST FLOOR
177SECOND FLOOR
178TERRACE FLOOR
179Providingandapplyingprimingcoatonconcrete/masonary/AsbestosCementplastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required including all leads and lifts etc.complete.
180GROUND FLOOR
181FIRST FLOOR
182SECOND FLOOR
183TERRACE FLOOR
184Providing and applying plastic emulsion paint of approved quality, colour and shade tonew surface in three coats including scaffolding, preparing the surface. (excluding primer coat) including all leads and lifts etc.complete.
185GROUND FLOOR
186FIRST FLOOR
187SECOND FLOOR
188TERRACE FLOOR
189Providingand applyingtwocoatsof exterioracraylicemulsion paintconfirmingto corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces includingcleaning,preparingtheplastersurface,applyingprimercoat,scaffoldingif necessary , and watering the surface for two days including all leads and lifts etc.complete.
190GROUND FLOOR
191FIRST FLOOR
192SECOND FLOOR
193TERRACE FLOOR
194Providing and fixing four fold partly panelled partly glazed door with fan light of required size as per detailed drawing with Indian Superior teak wood frame of size 150 mm x 100 mm, Indian superior teak wood shutter 35mm thick consisting of styles 125 mm x 35 mm fringe rail 125 mm x 35 mm Lock Rail of 150 mm x 35 mm and bottom rail 250 mm x 35 mm including 35 mm thick eitched float glass with stainless steel grill ( 15 Kg. /Sqm.) including finishing with two coats of meiamine polish etc complete.
195GROUND FLOOR
196Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia bars 3 Nos. And strips @250 mm c/c and fixing in wall with 6 Nos. of hold fast of 12 mm dia bars 500 mm long including primer and oil painting including all leads and lifts etc.complete. ) frame size 60 mm x 125 mm
197GROUND FLOOR
198FIRST FLOOR
199SECOND FLOOR
200TERRACE FLOOR
201Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panelswithoutventilatorasperdetaileddrawingexcludingthedoorframe,stainlesssteel fixtures and fastening and finishing the wood work with oil painting 3 coats including all leads and lifts etc.complete.
202GROUND FLOOR
203Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium platedfixturesandfastenings,withbrassmortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish including all leads and lifts etc.complete.
204GROUND FLOOR
205FIRST FLOOR
206SECOND FLOOR
207TERRACE FLOOR
208Providing and fixing 30mm thickPVC FLUSH L DOOR SHUTTER consisting of panel of hollow PVC profile of 20 mm thickness consisting frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mminserted inside the hollow section of stiles rails top ?and bottom railsandtwo19x19mm MStubesinsertedhorizontallyinsidethe hollowprofile section using 4/5 mm sheet using screws hollow profile shall be lipped with 10 mm (5mm x2) thickx20mmwidthonstilesandrailsusingsolventcement.Theinnerpanelshallbe laminatedwith5mm thicktermite proofwaterproof plain/prelam PVCsheet using solvent cementonthebothsidesofthepanelincludingstainlesssteelfixturesandfastening including all leads and lifts etc.complete as per direction of Engineer incharge, manufacturers specification and drawing.
209GROUND FLOOR
210FIRST FLOOR
211SECOND FLOOR
212Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12mmwithrollerwheelsconfirmingtogradeF.G.150fittedwithsnapheadedrivetsof minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clearspaceof150mmbetweentwosetsofcrossingswithholdfasts,stoppers,spaces, handles, locking arrangement and one coat of red lead primer and oil painting including all leads and lifts etc.complete.(I.S. 105211983).
213GROUND FLOOR
214Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Square Metre asperdrawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting including all leads and lifts etc.complete.
215GROUND FLOOR
216FIRST FLOOR
217SECOND FLOOR
218TERRACE FLOOR
219Providing and fixing in position U.P.V.C.(Unplasticized Poly Vinyl Chloride) having multi- chamberedouterframe section(73x50)mm withanouterwallthicknessof 2mm andsteel reinforcement,multi-chamberedsliderframe(73x60)mmwithsteelreinforcement,multi- chamberedslidersash(46x82)mmwithsteelreinforcementdesignedtogiveoptimum strength, 5 mm thick tougheneddouble glass with12 mm spacer of good quality including alluminium track, Inter-locking profile, coextrudedbeadings, EPDM gaskets,silicon sealent,sliding handle, fixtures and fastenings (couplings, hinges) including with all required screwsandnutswithallnecessaryU.P.V.C.sectionsasperthedetaileddrawingandas directed by Engineer-In-Charge etc. complete.
220GROUND FLOOR
221FIRST FLOOR
222SECOND FLOOR
223TERRACE FLOOR
224Providing and fixing in position powder coated aluminium louvered windows / ventilator of varioussizeswithpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality including all leads and lifts etc.complete.
225GROUND FLOOR
226FIRST FLOOR
227SECOND FLOOR
228Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt.Including all leads and lifts etc.complete.
229GROUND FLOOR
230Providing and Fixing mat finish stainless steel (of 302 grade ) railing with toppipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75mmdiameter including all leads and lifts etc.complete. (PriorapprovalofsampleandbrandbyEx.Engineeris necessary before use)
231GROUND FLOOR
232FIRST FLOOR
233SECOND FLOOR
234Providingandfixinginpositionaluminiumfixedwindowfullyglazedofanysizeasper detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glassincluding all leads and lifts etc.complete. Note While arriving atthe rateofitem ofitem weightat6.90 Kilogram/ One Square Metre is considered.
235GROUND FLOOR
236FIRST FLOOR
237Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed including all leads and lifts etc.complete.
238GROUND FLOOR
239FIRST FLOOR
240SECOND FLOOR
241Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed including all leads and lifts etc.complete.
242GROUND FLOOR
243FIRST FLOOR
244SECOND FLOOR
245Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed including all leads and lifts etc.complete.
246GROUND FLOOR
247FIRST FLOOR
248SECOND FLOOR
249Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed including all leads and lifts etc.complete.
250GROUND FLOOR
251FIRST FLOOR
252SECOND FLOOR
253Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed including all leads and lifts etc.complete.
254GROUND FLOOR
255FIRST FLOOR
256SECOND FLOOR
257Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion including all leads and lifts etc.complete.
258TERRACE FLOOR
259Providing and fixing on walls/ ceiling/ floors, 40 mm dia. heavy grade having embossed as ISIMarkgalvanisedironpipesweightof4.49Kilogram/meterwithnecessaryfittingsand remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed including all leads and lifts etc.complete.
260GROUND FLOOR
261Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Markgalvanisedironpipesweightof6.33Kilogram/meterwithnecessaryfittings.and remakinggoodthedemolishedportionandprimerofanticorrossiveoilpaint2coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed including all leads and lifts etc.complete.
262TERRACEFLOOR
263Providing and fixing on walls/ ceiling/ floors, 80 mm dia.heavy grade having embossed as ISI Markgalvanisedironpipesweightof10.15Kilogram/meterwithnecessaryfittings.and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed including all leads and lifts etc.complete.
264GROUND FLOOR
265Providing,layingandfixingP.V.C.pipeof50mmdia.withfittingssuchasbends,tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removingexistingpipelineifnecessaryandconveyingandstackingthesameinPWD chowky or as directed including all leads and lifts etc.complete. .
266GROUND FLOOR
267FIRST FLOOR
268SECOND FLOOR
269Providingandfixing75mmdiastabiliserpipe/P.V.C.soilvent/wastepipeandwith necessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps including all leads and lifts etc.complete.
270GROUND FLOOR
271FIRST FLOOR
272SECOND FLOOR
273Providingandfixing100mmdiastabiliserpipe/P.V.C.soilvent/wastepipeandwith necessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps including all leads and lifts etc.complete.
274GROUND FLOOR
275FIRST FLOOR
276SECOND FLOOR
277ProvidingandfixingP.V.C.Rainwaterpipesof160mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.ormasonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge including all leads and lifts etc.complete.
278GROUND FLOOR
279FIRST FLOOR
280SECOND FLOOR
281TERRACE FLOOR
282Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench including all leads and lifts etc.complete.
283GROUND FLOOR
284Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut including all leads and lifts etc.complete.
285GROUND FLOOR
286FIRST FLOOR
287SECOND FLOOR
288Providing and fixing 25 mm dia. screw down bib/ stop tap of brass including necessary socket union nut including all leads and lifts etc.complete.
289GROUND FLOOR
290FIRST FLOOR
291SECOND FLOOR
292Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut including all leads and lifts etc.complete.
293GROUND FLOOR
294FIRST FLOOR
295SECOND FLOOR
296Providingandfixingscrewdownfor20mmdia.wheeledstoptapofbrassincluding necessary sockets/union nut including all leads and lifts etc.complete.
297GROUND FLOOR
298FIRST FLOOR
299SECOND FLOOR
300Providingandfixingscrewdownfor40mmdia.wheeledstoptapofbrassincluding necessary sockets/union nut including all leads and lifts etc.complete.
301GROUND FLOOR
302FIRST FLOOR
303SECOND FLOOR
304Providingandfixingscrewdownfor50mmdia.wheeledstoptapofbrassincluding necessary sockets/ union nut including all leads and lifts etc.complete.
305GROUND FLOOR
306FIRST FLOOR
307SECOND FLOOR
308Providingandfixingscrewdownfor80mm.dia.wheeledstoptapofbrassincluding necessary sockets/union nut including all leads and lifts etc.complete.
309GROUND FLOOR
310FIRST FLOOR
311SECOND FLOOR
312Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories including all leads and lifts etc.complete.
313GROUND FLOOR
314FIRST FLOOR
315SECOND FLOOR
316Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut including all leads and lifts etc.complete.
317GROUND FLOOR
318FIRST FLOOR
319SECOND FLOOR
320ProvidingandfixingC.P.TwowayBIBcockofapprovedmakecontinental including necessary sockets/union nut including all leads and lifts etc.complete.
321GROUND FLOOR
322FIRST FLOOR
323SECOND FLOOR
324Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bendpipeandwallflangeofapprovedmakeincludingnecessarysockets/unionnutincluding all leads and lifts etc.complete.
325GROUND FLOOR
326FIRST FLOOR
327SECOND FLOOR
328Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut including all leads and lifts etc.complete.
329GROUND FLOOR
330FIRST FLOOR
331SECOND FLOOR
332Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mmdia. nickel plated towel rod including all leads and lifts etc.complete.
333GROUND FLOOR
334FIRST FLOOR
335SECOND FLOOR
336Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories including all leads and lifts etc.complete.
337GROUND FLOOR
338FIRST FLOOR
339SECOND FLOOR
340Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32mm dia. P.V.C flush pipe withfittings andflushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall. Including all leads and lifts etc.complete.
341GROUND FLOOR
342FIRST FLOOR
343SECOND FLOOR
344Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Including all leads and lifts etc.complete.
345GROUND FLOOR
346FIRST FLOOR
347SECOND FLOOR
348ProvidingandfixingwhiteglazedearthenwareWashHandBasinof55cm.x40cm.size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing including all leads and lifts etc.complete.
349GROUND FLOOR
350FIRST FLOOR
351SECOND FLOOR
352Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and ofspecialcolourshadehavingtelephonicblack/colouredgraniteof180mm thickstone blackkadappaframeworkincludingchromiumplatedcouplingbottle-TrapusingCERA companyorequivalentovaltypawashbasinmodelno 3448asperdetaileddrawing oras directed by engg incharge including all leads and lifts etc.complete. (Counter size 1.20 m x 0.60 m )
353GROUND FLOOR
354FIRST FLOOR
355SECOND FLOOR
356Providingandfixingstainlesssteelsinkofsize600x510x200mm incluidngcoupling, outlet pipe, elbow and other necessary fitting, finishing including all leads and lifts etc.complete.
357GROUND FLOOR
358Providing andfixing 10cm C.I.NahaniTrapincludingC.I.gratingbendandpiece ofC.I. pipe upto the outside face of the wall including all leads and lifts etc.complete.
359GROUND FLOOR
360FIRST FLOOR
361SECOND FLOOR
362Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Including all leads and lifts etc.complete.
363GROUND FLOOR
364ProvidingandfixingOrissatypewhiteglazedearthenware575mmwaterclosetpan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories including all leads and lifts etc.complete.
365GROUND FLOOR
366FIRST FLOOR
367SECOND FLOOR
368Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jetandfittingincludingcuttingandmakinggoodtothewallsandfloorstestingincluding all leads and lifts etc.complete. (prior approval of sample and brand by Ex. Engineer is necessary before use)
369GROUND FLOOR
370FIRST FLOOR
371SECOND FLOOR
372ProvidingandconstructingBrickMasonryInspectionChamber60cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75 Kilogram with lid and frame fixed in cement concrete. Including all leads and lifts etc.complete.
373GROUND FLOOR
374Providing andconstructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raftinB.C.soilareaincludingcostofreinforcement,1:2:4cementconcretechannelshalf round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover medium duty 100 Kilogram including all leads and lifts etc.complete.
375GROUND FLOOR
376Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber including all leads and lifts etc.complete. Heavy duty (225 Kilogram)
377GROUND FLOOR
378Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber including all leads and lifts etc.complete. Heavy duty (160 Kilogram)
379GROUND FLOOR
380Providingsoakpitofsize 120cm x120cm x120cmincluding excavatingandfilling with brick-bats. Including all leads and lifts etc.complete.
381GROUND FLOOR
382Providing and fixing H.D.P container one piece moulded water tank made out oflowdensitypolythylerandbuiltcorrugationincludingofdeliveryuptodestination hoisting andfixing of accessories such as inlet, outlet overflow of alltanks capacityabove 1000 to 20,000 litres including all leads and lifts etc.complete.
383TERRACE FLOOR
384Providing andfixing in positionUPVC ultra violet stabilized110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement including all leads and lifts etc.complete.
385TERRACE FLOOR
386Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility and strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 One Numbers self-drilling screws and trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12mm thick panels shall be used for a roofing height of upto 15 mtrs.Including all leads and lifts etc.complete.
387GROUND FLOOR (Parking)
388TERRACE FLOOR
389Providing and fabricating structural steel work in rolled sections like joists, channels, angles, teesetc.asperdetaileddesignanddrawingsorasdirectedincludingcutting,fabricating, hoisting,erecting,fixinginpositionmakingriveted/bolted/weldedconnectionswithout connecting plates, braces etc. andincluding one coat of anticorrosive paint andover ittwo coats of oil painting of approved quality and shadeincluding all leads and lifts etc.complete.
390Ground Floor ( Parking)
391TERRACE FLOOR
392Providing and fixing mat finish stainless steel lettering of various heights as directed by Engineer in Charge including material labour cleaning etc Complete
393From 30 to 45 cm height
394Providingandfixing90cmx60cmMarbleplateengraving10cm.heightletter,figures including painting the lefters/figures with approved colour and shade complete
395Turbo Ventilator 24\"
396Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each not less than 0.50 mm thick, total thickness of aluminium composite panels not to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat not less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating not less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in no case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge
397Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling ofapprovedtextureofsize595mmx595mmintrue horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanisingat@12gm/sq.mincludingbothsides) consistingofmainTrunnersuitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoatedsteel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet withthe help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm ofallT-sectionsshallbeprepaintedwithpolyesterbakedpaint,forallheights,asper specifications, drawings etc. complete.(currently this item should be used only for VIP cabins)
398GROUND FLOOR
399FIRST FLOOR
400SECOND FLOOR
401RWH - Recharge PitProviding andconstructing rechargepitof2.0m deepand1.0m diaofpre-castRCCrings with6.5\"diax25mdeepborewellatthefloorofrechargepitincludinginstallationof combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mmthicksidefillingaroundoutsideofRCCrings(annularspace)with40mmsize bouldersincludingfillingofrechargepitupto0.5mdepthwith25-75mmcleanwashed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.)includingnetlonmeshbetweeneachgravel/fineaggregate(naturalsand/crushedsand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame and cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet and outlet pipe excavationand backfilling as shownin the drawing.The rate shall be inclusive of alllabour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All materialshouldbeofapprovedmake.Allworkscompleteasperthedrawing,technical specification and direction of the Engineer in charge.
402Boring/drillingborewellof300mmdiaforcasing/strainerpipe,bysuitablemethod prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing andsubmittingstratachart/borelog,includinghireandrunningchargesofallequipments, tools, plants and machinery required for the job, all complete as per directionof Engineer in charge, upto 90m depth below ground level.
403Supplying,assembling,loweringandfixinginverticalpositioninborewell,unplasticized PVCmedium well-casingpipe of150mm dia,conforming toIS:12818,includingrequired hireandlabourcharges,fittingsandaccessoriesetc.allcomplete,foralldepths,asperthe direction of Engineer in charge.
404Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms and three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern and wash basin fittings,nuts, bolts and gasket etc complete as per the direction of Engineer-In-charge.
405GROUND FLOOR
406FIRST FLOOR
407SECOND FLOOR
408Providing and laying in place 300mm x 300mm x 9.8mm vitrified tactile warning and directional tiles of the approved brand, make and colour inside the buildings at in all corridors and lobbies, level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer including zarri making wherever required and finishing including grouting the joints with white cement with matching pigments etc. up to the satisfaction of the engineer in charge complete.
409GROUND FLOOR
410FIRST FLOOR
411SECOND FLOOR
412Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6\"x 9\" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge.
413GROUND FLOOR
414FIRST FLOOR
415SECOND FLOOR
416Providing and fixing ISI marked double swing flush door shutters conforming to IS :2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including ISI marked Stainless Steel L- hinges with necessary screws Fittings and Fixturesper leafSS kick plates on both sides of the door of 300mm heightHeavy Duty satin finish butt SS Hinges (100mm x 75mm x 3mm in size)-4 nos. SS finishedlever handle with mortise lock- 1 One NumberFloor spring- 1 One Number 100mm x 100mm safety glass at the specified location
417GROUND FLOOR
418FIRST FLOOR
419SECOND FLOOR
420Providingandfixingdoublescaffoldingsystem(cuplocktype)ontheexteriorsideof building/structure,includingadditionalrowsofscaffoldinginstepped mannerasper requirementofsite,madewith40mmdiaM.S.tube,placed1.5metrecentretocentre, horizontal and vertical tubes joint with cup and lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining itinaserviceableconditionforexecutionofworkofcleaningand/orpointingand/or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, whereverrequired,iffeasible,for inspection of work at required locations with essential safety features for the workmen etc., completeasperdirectionsandapprovalofEngineer-in-charge. Note:-(1)Theelevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
421GROUND FLOOR
422Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.
423Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.
424Providing earthwork in embankment with approved HARD MATERIAL having PI<6 obtained from other sources upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-S atattachment to achieve not less than 97% of standard proctor density etc. complete ( Material obtained from Other sources)
425Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
426Spreading hard murum/ soft murrum/ gravel or kankar for side width complete
427Compacting the hard murum / kankar for all widths (200 mm Loose ) with vibratory roller including necessary artificial watering complete a) By Vibratory Roller
428Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.
429Providing granular sub base (drainage layer )by coarse graded materials confirming tograding-II of Table-400-2 of MORT & H in50:30:20 proportion of 40 mm, 20 mm crusherbroken metal and sand respectively, spreadingon prepared surface, mixing by mix in placemethod at OMC and compacting to achievethe desired density etc. complete as per clause401 for grading-II material etc complete. (B) Compaction by Vibratory Roller
430Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Intelligent Compactor with compaction analyzer and V-Sat attachment. to the required density.Grading I(Using Screening Type A (13.2) mm Aggregate)
431Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Intelligent Compactor with compaction analyzer and V-Sat attachment. to the required density. Grading II(Using Screening Type B (11.2 mm) Aggregate)
432Watering and compaction the embankment formed of materials obtained from the road cutting departmental land or other sources within a lead of 50 m. after laying them in layers of 20 to 30 cm with 3% Cmber and design superelevation etc. complete. ( Compaction with power roller )
433Providing and constructing 75 mm. thick ModifiedPenetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 30% crusher broken metal + 70% Hand broken (by breaking rubbleobtained by blasting) heating and spraying thebitumen of VG-30 @ 2 Kg/sqm, spreading 12 mm.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete.Including picking of existing WBM surface. a) On existing WBM surface including picking.
434Open Graded Premix Surfacing- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but including prime / tack and Seal coat. For Bitumen of VG-30-USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( Over BT Surface)
4359 MM SEAL COAT: Providing and laying of Type A 9mm premix seal coat with HMP of apropriate capacity crushed stone chiping 6.7 mm size and penetration bitumen of VG-30 @ 1.2kg/Sq.m,preparing existing road surface by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete.
436Providing and laying cement concrete pipe of IS 458:2003 NP-2 class of 900mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
437Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.
438Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete.
439Providing and fixing Road junction / Information sign board of size 0.90 m x 0.60 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35x35x5 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/ white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral / arrows, coated with non pealable crystal clear protective coat retaining 100% reflection including two angle iron post of size 50x50x5 mm of 3.65 m. long inflated at bottom drilled on top and painted in white and black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size as directed by Engineer-in-charge etc. complete. Mild Steel Board with Engineering Grade.
440Excavation for foundationin earth, soils of all types, sand, gravel, soft murum including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directedetc. complete. ( By /manaual Means )a) Upto 1.50m lift Normal Rateb) 1.50m to 3.00m lift, Add 10%c) 3.00m to 4.50m lift, Add 20%d) 4.50m to 6.0m lift, Add 30%
441Providingsoling using80mm sizetrapmetalin15cm.layerincludingfilling voidswith Crushed sand/grit, ramming, watering etc. complete.
442Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneiss metalforR.C.C.work infoundationslikeraft,stripfoundations,grillageand footingsofR.C.C.columnsandsteelstanchions etc.includingbailingoutwater, Steel centeringformwork,laying/pumpingcoverblocks,compactionandcuring roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
443Providing cast in situ / ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with reversible drum type mixer/ concrete batch mix plant (pan mixer)with SCADA
444Providing and laying in situ / ready mix M-20 cement concrete of trap /granite /quartzite /gneiss metal for approach slab / Rigid pavement including compacting, finishing, curing etc. complete. (excluding reinforcement) (with reversible drum type mixer/ concrete batch mix plant (pan mixer)with SCADA with fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ), cement 6.40 bags/cumt)
445Providing, cutting, bending, hooking, tyingand laying in position TMT FE 500 steel bars for reinforcement for all RCC works as per detailed drawings etc. complete.
446Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete.
447ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
448ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirectedincludingsteelcentering,formwork,coverblocks,laying/pumping, compactionandrougheningthesurfaceifspecialfinishistobeprovidedandcuringetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
449Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete
450Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete.
451Providing and applying two coats of exteriorweather shield paint of approved manufacture andofapprovedcolourtotheplasteredsurfacesincludingcleaning,preparingtheplaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etccomplete. NOTE: ForItem One Number 15 to 18 prior approval of Superintending Engineer will be necessary
452Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete.
453Providing and fixing M.S. grill door 24 Kilogram/ Sqm of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
454Providing earth work in embankment with approved materials obtained from other sources upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm. thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97 % of standard proctor density etc. complete( Material obtained from Other sources)
455Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top andbottom of 25 x 25 x 5 mm size andvertical M.S. flat 35 x 5 mm and25 x 5mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete.
456GARDEN SOIL: -Supplying on site garden soil well sieved 80 % to pass through I.S. sieve of 10 mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The color of the soil generally is red. The soil will be measured by measuring box. (Farma)Item includes Transporting, loading -unloading etc.
457FARM YARD MANURE: -Supplying on site well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material. The color of the manure generally is black. The manure will be measured by measuring box. (Farma)Item includes Transporting, loading -unloading etc ( Lead charges per 20 km. considered.)
458Supplying of various Tall plants
459Plumeria Rubra
460Plumeria Dwarf singapore pink
461Cyperus golden
462Cycas
463Gulmohar
464Kadamb
465Wad/banyan
466KaduNeem
467Coconut
468Bismarkia
469Fox tail palm
470Royal palm
471Flowering Plants
472Poinsettia
473Ixora
474Dracaena Golden
475Money Plant Marble
476For Preparation of 30cm Lawn 100 Sqm
477Supplying on site fresh Garden soil (free from stones rubbish like dried grass roots, other such materials) for excavation area of depth of 30 cms.( consolidated thickness)
478Supplying on site well decomposed Farm Yard Manure for excavation area of depth of 30 cms. ( consolidated thickness)
479Providing on site required variety of lawn (free from weeds /diesease etc.) Cynadon/ paspalum/ selection for 1 sqm. area dibbling distance 5 cms. apart c/c.
480Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms.
481Filling fresh garden soil / silt & manure inexcavated area of depth 30cms.
482Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting reqired plant species, lawn grass as directed etc. complete for required depth 30 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover.
483Maintainance of Newly Developed lawn Area. For First 30 days Only (Paspallum/ selection)
484For Preparation of Shrubbery 20cm depth 100 Sqm
485Providing on site required variety of Shrubs (free from weeds /diesease etc.) 30 cms. apart c/c.Name:-Murraya(Kamini);Bag Size 7\"\" x 8\"
486Maintainance of Newly Developed Shrubs Area. For First 30 days Only
487Executive\"sTable @ 1800Lx900Dx750HT Providing and Fixing of Table @ 1800Lx900Dx750HT - TOP and GABLE END to be made ofMembrane finish with soft water fall edges and curved panel and Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing
488GROUND FLOOR
489FIRST FLOOR
490SECOND FLOOR
491Pedestal Unit @ 420Lx450Dx650HT Providing and Fixing of PEDESTAL @ 420Lx450Dx650HT :- To be made out of Complete Membrane consist of three Drawers as per drawing.
492GROUND FLOOR
493FIRST FLOOR
494SECOND FLOOR
495Credestal @ 1200Lx450Lx650HT Providing and Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H:- To be made out of Membrane Finish ( 2 Openable Shutter and 3 Drawer Pedestal in between )as per drawing.
496GROUND FLOOR
497FIRST FLOOR
498SECOND FLOOR
499Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing and Fixing of Table@ 2250Lx2100Dx750HT TOP and GABLE END to be made ofMembrane finish with soft water fall edges and curved panel and Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H:- To be made out of Membrane Finish ( 2 Openable Shutter and 3 Drawer Pedestal in between ) as per drawing.
500GROUND FLOOR
501FIRST FLOOR
502SECOND FLOOR
503Medium Height Partition @ 1800/1200HTTILE BASED PARTITION SYSTEM:-Tile based Aluminum partition system of 1800/1200 mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical and computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/ exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look.Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board lower tiles in laminate finish of 9mm. thk. on both the sides.
504GROUND FLOOR
505FIRST FLOOR
506SECOND FLOOR
507Free Standing Table @ 1500Lx600Dx750HTProviding and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board.All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine.Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :-Metal Powder Coated - Black Color, CPU TROLLEY :-Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
508GROUND FLOOR
509FIRST FLOOR
510SECOND FLOOR
511Free Standing Table @ 1350Lx600Dx750HTProviding and fixing Table of Size 1350 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board.All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine.Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :-Metal Powder Coated - Black Color, CPU TROLLEY :-Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
512GROUND FLOOR
513FIRST FLOOR
514SECOND FLOOR
515Providing and Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HTProviding and Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT, Curvilinear Table Top @ 1500/1500Lx600/600D :- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band,GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :-Metal Powder Coated - Black Color, CPU TROLLEY :-Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
516GROUND FLOOR
517FIRST FLOOR
518SECOND FLOOR
519Conference Table @ 3600Lx1400Dx750HTProviding and Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos.
520GROUND FLOOR
521FIRST FLOOR
522SECOND FLOOR
523Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body and shutter made in0.8 mm thick and Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk additional Top on top of storage as as per drawing
524GROUND FLOOR
525FIRST FLOOR
526SECOND FLOOR
527Medium Height Steel Storage @ 750Lx450Dx1200HTProviding and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body and shutter made in0.8 mm thick and Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk. as per drawing.
528GROUND FLOOR
529FIRST FLOOR
530SECOND FLOOR
531Full Height Steel Storage @ 750Lx450Dx2100HTProviding and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body and shutter made in0.8 mm thick and Topin 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.
532GROUND FLOOR
533FIRST FLOOR
534SECOND FLOOR
535Providing and Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT.
536GROUND FLOOR
537FIRST FLOOR
538SECOND FLOOR
539Providing and Arrangemnt of MId Back, Normal SyncroMechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery
540GROUND FLOOR
541FIRST FLOOR
542SECOND FLOOR
543Providing and Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery
544GROUND FLOOR
545FIRST FLOOR
546SECOND FLOOR
547Public Seating Chair. - 3 SeaterProviding and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.
548GROUND FLOOR
549FIRST FLOOR
550SECOND FLOOR
551ProvidingandfixingheavydutyinterlockingconcreteColouredpavingblocksof80mm thickness of having a strength of 300 Kilogram/Sq.cm. of approvedquality andshape ona bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete
552Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
553Supplying and laying HMS PVC conduit FRLS grade 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
554Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
555Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
556Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
557Supplying and laying HMS PVC conduitFRLS grade 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
558Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
559Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
560Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
561Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
562Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
563Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
564Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
565Supplying and erecting mains with 4x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
566Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
567Supplying and erecting mains with 4x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
568Supplying and erecting mains with 1x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
569Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
570Supplying and erectingmodular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
571Supplying and erectingmodular type switch 16 / 20 Awith indicator,duly erected on provided plate and box with wiring connections complete.
572Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete.
573Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.
574Supplying and erecting PVC Surface modular switch box with double mounting plate for 2module duly erected.
575Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
576Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
577Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
578Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
579Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
580Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW
581Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and requiredaccessories as per specification No: WG-PW/CW
582Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVCconduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW.
583Point wiring for light/bellhybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls)in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
584Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls)in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
585Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
586Supplying and erectingLED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
587Supplying and erectingLED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
588Supplying and erectingLEDPanel Light(600mm X 600mm) Max. 30 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
589Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
590Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
591Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17Wwith high transitivity diffuser withsystem lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%,p.f. >0.95, operating range of120-270V, surge protection of 4 kV, Life class of50,000 Hrs. at L70B50, includingdriver, with end caps on provided PVC Block / wooden board with 3 years warranty.
592Supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
593Supplyinganderectingluminous / modular type call bell indicator with plasticbody, heavy duty coil and indicatorlamp working on 230V A.C. supplywith resetting arrangement complete erectedondouble wooden/ sunmica board.
594Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2.
595Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2.
596Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
597Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.
598Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF
599Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
600Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original.
601Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. (308X1.2 = 369.6 Mtr )
602Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm.
603Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC
604Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC
605Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. AP-WCR/WC
606Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
607Supplying,erecting, testing and commissioning of10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) havingminimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hzincoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V ACat each socket with 3.5\"TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mmduly RAL7035 Coated M.S, Erected oniron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming toIS 17017 Series as per specification.
608Supply, Installation, Testing and Commissioning 7.2 kW AC Electric Vehicle charger (suitable for 4 wheeler) having minimum IK08 & IP54protection suitable for single phase, 230V AC, 50Hz, incoming and 1 nos. outputhaving capacity of output current of 32A at 230V with Type two connector as per IEC 62196-2 , Interlocking arrangement & minimum 5 meter charging cable length,3.5\" TFT screen for human interface & LEDlight for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for server communication, emergency push stop button, with user interface by mobile application/QR Code/RIFD Card/Password Login and having short circuit, over & under voltage, overload, earth leakage ,Over temperature, surge protectionand enclosure made of minimum 1.5mmduly RAL7035 coated M.S, erected oniron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming toIS 17017 Series as per specification
609Providing yearly subscription of payment gateway option for AC/DC EV Charger CMS (Charger management software) system for billing and payment gateway along with mobile application /android/IOS base app to facilitate charging, CMS should have ISO/IEC 27001:2003 certification.
610Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
611Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
612Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
613Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
614Supplying&erecting triplepole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase(12 poles), with door,1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GIframe (horizontal busbar type) as per specification no. SW-SWR/MCBDB
615Supplying&erectingtriplepole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flushmounted,IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
616Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
617Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plugtop with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame.
618Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
619Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TPMCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
620Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), withdoor, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
621Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
622Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB( 5309 * 1.2 = 6370.80 )
623Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB( 14159 * 1.2 = 16990.80 )
624Supplying, fixing and commissioning 2 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO
625Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO
626Supplying, fixing and commissioning4 pole RCBO 63A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
627Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for four pole incoming 250A, 8 ways Four pole outgoing, up to 100 A MCCBs on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCBs)
628Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door, 250A incoming and 8 way outgoing or 400A incoming and 6 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway andDB.
629Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.
630Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to 800A MCCB.
631Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982
632Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.
633Supplying and erecting 75 kVAr, 440 V 3 phase, 50 Hz., Contactor Logic & Intelligent Relay micro APFC passive filter panel, consisting of suitable steps of APP/MPP type capacitor units with Detuned (harmonic filter) reactors of suitable rating ,APFC panel shall be compliance to IEC 61439 and power qualityIEC 61921 standard as per specification no CP-ED/APFC
634Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
635Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
636Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
637Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core16sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
638Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core25sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
639Supplying & erectingG.I. pipe ‘A’ class75 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE
640Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
641Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mmoutside dia. double wall corrugatedpipes (DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.
642Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP
643Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP
644Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbonbased environment friendly back fill Ground Enhancing compoundcomplete with all materials, testing & recording the resultsas per specification no ESE -LA
645Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
646Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
647Providing and back filling ground enhancing compound 25 kg bag complete.
648Supplying & erecting Motion /Occupancy Sensor Ceiling/ false ceilingmounted, sleek premium finished body3 adjustable onboard knobs , 1) off time, 2)Light Sensitivity, 3) Motion sensitivity , Environment friendly,360 degree indoormovement detector,suitable for 230 V 1000 watt circuit load, duly connected with required material .Similar to Schneider Electric make Model Argus No CCT570005. (Rate as per Sanctioned Estimate No 265/EE/AMT/2020-21)
649Supplying ,erecting & CommossioningSmart Comm Energy Management System (EMS)with software for 20 nodesMFM 4410 LED C1 1 with RS485 & ,multifuction meters,all hardware & cable laying with requred accessories such as CT,PT etc.enclosed Converter ,Ethernet switch ,lan van point, static IP\"s,1/port RS485Serial to Modbus TCP/IP gateways,Ethrtnet switch 8ways-Gigabit with shielded twisted cable 2 core 0.5 mm & Cat -6 data cable duly erected on pannelconnected to provided P.C. Sinilar to L & T make(Rate as per Sanctioned Estimate No 265/EE/AMT/2020-21)
650Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
651Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
652Supplying and erectingmodular type computer Jack RJ45 with safety shutter, duly erected on provided plate and box with wiring connections complete.
653Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
654Supplying and installingcat-6 LSZH cable suitable for networking as per specification no. WG-COC/NC
655Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
656Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
657Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS
658Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL
659Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
660Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
661Supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit
662Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
663Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV
664Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2.
665Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation.
666Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB
667Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
668Supplying & erecting G.I. pipe‘A’ class 40 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE
669Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.
670Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
671Providing and erecting galvanised 1500 mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
672Providing and erecting galvanised 1500 mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
673Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP
674Providing and back filling ground enhancing compound 25 kg bag complete.
675Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. (V = 9 X 0.45 X 0.4 X 2 nos) + (0.4x.45x0.4 x2 ) = 3.24 + 0.144 =3.38 say 3.5 cu.mtr. )
676Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). (V = 9 X 0.45 X 0.4 X 2 nos) + (0.4x.45x0.4 x2 ) = 3.24 + 0.144 = 3.38 say 3.5 cu.mtr. ))
677MakingM- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
678Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
679Supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit
680Supplying and erecting mains with 4x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
681Supplying and erecting switch disconnector fuse (SDF) 415V, 25/32A, with enclosure, triple pole and neutral link AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3 HRC - DIN type fuse switch , insulation voltage 1000 V, with rotary handle for ON / OFF operation (without HRC fuse)
682Supplying &erecting four poleON LOAD change over switch, 415V,40A,open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit,rotary handle,operational current category AC23A complying to IS/IEC 60947-3 Part-1/3.
683Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
684Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
685Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
686Supplying&erectingtriplepole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flushmounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
687Supplying, fixing and commissioning4 pole RCBO 63A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
688Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete.
689Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.
690Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.
691Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
692Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core25sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
693Supplying & erectingG.I. pipe‘A’ class25 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE
694Supplying & erecting G.I. pipe‘A’ class 40 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE
695Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.
696Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP
697Providing and back filling ground enhancing compound 25 kg bag complete.
698Supplying and erecting minimum Three & above star rated submersible pump set of 4.5 KW/6 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 60 to 180 LPM discharge at 177 to 88 m head & discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP
699Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute &pipe of Suction 65mm / Delivery 50 mmdiameter erected with necessary H type clamps as per specification No. WP-OSP
700Supplying & erecting flat flexible 3 core 6 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
701Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
702Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).
703Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
704Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet/submersible pump with required material complete.
705Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete.
706Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
707Supplying and erecting CI flange 50 mm. dia with necessary nuts bolts and washers with rubber seal in position complete.
708Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982
709Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core185 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
710Supplying & erectingG.I. pipe ‘A’ class75 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE
711Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
712Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mmoutside dia. double wall corrugatedpipes (DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.
713Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP
714Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint with joints required as per specification no EA-EP.
715Supplying, erecting, testing and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 34.40 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB(A) at 1.0 m, provided with first filling of oil, diesel not less than 300 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
716Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 180 kVA up to 200 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. ( FR- 185054 /- Reduce by 10 % = 166548.60 )
717Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. (5 X 3 X 0.7+5X3X 0.7=10.50 CuM)
718Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). (4.5 X 2.5 X 1+4.5 X 2.5 X 1= 11.25 +11.25 CuM )
719Supplying and erecting ISI mark GI pipe 75/80 mm dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.
720Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
721Cassetee AC
722Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
723Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
724Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.
725Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system
726Supplying, laying / fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 41.3 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
727Supplying, laying / fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees,valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
728Supplying, laying / fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
729Supplying, laying / fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system
730Supplying, laying / fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
731Supplying, laying / fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
732Supplying, laying / fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
733Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
734Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
735Supply, Installation, Testing and Commissioning of drain piping conformimg to IS :1239 /3589 heavy class inculding all fitting like anchor fasteners , pipe supporting , frame structure , coupling , bends, elbows, tees, flanges, tappings, wall sleeves, hangers and rigid polyurethane foam block etc. Pipe should be insulated with 9 mm thick EPDM rubber with adhesive.
73625 mm Dia
73732 mm Dia
738Supplying and erecting iron, sheet metal work consisting ofCRCA sheets, various sections of iron, plates, chequeredplates, rods, bars, MS pipes, etc. for panel board or anyother purpose with bending, cutting, drilling and weldingcomplete erected at the position with necessary materialsduly painted with one coat of red oxide and two coats ofenamel paint to match the switchgears or as per directions by the authority.
739Providing vaccumising the airconditioner system to 200 micron and charging with R-410A/R32 refrigerant for air conditioning unit.
740Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 500 mm width & 100 mm height comprising all required standard accessories
741Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 500 mm width & 20 mm height complete with necessary hardware in approved manner.
742Supplying, erecting & terminating XLPE armoured cable 3core 2.5 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
743Supplying, erecting & terminating XLPE armoured cable 4core 6 sq. mm. copper conductor continuous 5.48 sq. mm.(12 SWG) G.I. earth wire complete erected with glands &lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
744Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv
745Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. (CSR-3-11-77)
746Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
747Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
748Supplying and erecting 20mm dia. corrugated flexiblepolypropyleneconduit
749Supplying and erecting 25 mm dia. corrugated flexiblepolypropyleneconduit
750Supplying and erecting 15m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
751Supplying and installing enhanced cat-6 cable with 4-connector channel, performance test report as per ANSI/TIA-568.2-D suitable for networking complete as per specification.
752Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete.
753Supplying, fixing, and configuring 24 ports, POE switchin provided rack as per specification No. WG-NWC/ENS
754Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
755Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
756Supplying and fixing 32 U floormount server Rack (Dimension-DxWxH - 800X1000x1620 mm) as per specification No. WG-NAS/RAK
757Supplying, erecting, testingandcommissioning of 2kVA capacity online pure sine wave, with backup time of ...0.30 hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
758Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
759Supplying, erecting, Testing & Commissioning of 4MP Camera Bullet with necessary accessories i).Video Compression Ultra 265, H.265, H.264, MJPEGii)Video Resolution Sub Stream:2MP (1920×1080): Max. 30 fps; Third Stream: D1(720×576) : Max. 30fps iii)Frame RateMain Stream:4MP (2592×1520): . 20 fps,4MP (2560×1440): Max 25 fps,3MP (2048×1520): Max. 30 fps; Sub Stream:2MP (1920×1080iv)Image Sensor Intrusion, crossing line, motion detectionv)Lens Type 1/3\", progressive scan ,4.0 megapixel, CMOS vi)[email protected]) Minimum Illmage SettingsSMART Behavior Detection Intrusion, crossing line, motion detection , Intelligent Identification Face detection, IP Address Filtering viii) Image settings Rotate Mode, Saturation, Brightness, Contrast, Sharpness adjustable by client software or web browser ix)Audio Two-way audio Supported STORAGE Edge Storage Micro SD, up to 128 GB Network Storage ANR, NAS (Network Attached Storage)x) ProtocolL2TP, IPv4,IGMP,ICMP,ARP,TCP,UDP,DHCP,PPPoE,FTP, UPnP, HTTP, HTTPS, SMTP, SIP, 802.1xxi) Security IP Address Filtering, output, Access Policy,ARP Protection, RTSP Authentication, User Authentication xii)Operating ConditionsWide temperature range: -35°C to + 60°C (-31°F to 140°F), Humidity < 95% RH ( Non -Condensing)xiii) Intelligent IdentificationFace detection, Defocus, Scene Change xiv) Edge StorageMicro SD, up to 128 GBxv) Casing Metal
760Supplying, erecting, Testing & Commissioning of 4MP Camera Dome with necessary accessories :i).Video Compression Ultra 265, H.265, H.264, MJPEGii)Video Resolution Sub Stream:2MP (1920×1080): Max. 30 fps; Third Stream: D1(720×576) : Max. 30fpsiii)Frame RateMain Stream:4MP (2592×1520): , 20 fps,4MP (2560×1440): Max 25 fps,3MP (2048×1520): Max. 30 fps; Sub Stream:2MP (1920×1080iv)Image Sensor Intrusion, crossing line, motion detection v)Lens Type 1/3\", progressive scan ,4.0 megapixel, CMOSvi)Lens3.6mm @ F2.0, Angle of view ( H): 72.0° vii) Minimum Illmage SettingsSMART Behavior Detection Intrusion, crossing line, motion detection , Intelligent Identification Face detection, IP Address Filtering viii) Image settings Rotate Mode, Saturation, Brightness, Contrast, Sharpness adjustable by client software or web browser ix)Audio Two-way audio Supported STORAGE Edge Storage Micro SD, up to 128 GB Network Storage ANR, NAS (Network Attached Storage) x) ProtocolL2TP, IPv4,IGMP,ICMP,ARP,TCP,UDP,DHCP,PPPoE,FTP, UPnP, HTTP, HTTPS, SMTP, SIP, 802.1xxi) Security IP Address Filtering, output, Access Policy,ARP Protection, RTSP Authentication, User Authentication xii)Operating ConditionsWide temperature range: -35°C to + 60°C (-31°F to 140°F), Humidity < 95% RH ( Non -Condensing) xiii) Intelligent IdentificationFace detectionxiv) Edge StorageMicro SD, up to 128 xv) Casing Metal
761Supplying, erecting, Testing & Commissioning 4MP Camera PTZwith necessary accessories i).Video Compression:-H.265 /H.264 / MJPEG ii).Video Resolution :-1080P(1920×1080)/720P(1280×720)/D1(704×576/ 704×480), CIF(352×288/352×240,iii)Frame Rate :-Main Stream : 1080P(1~25/30fps), 720P(1~50/60fps), Sub Stream 2: 1080P/720P/D1/CIF (1 ~ 25/30fps), Sub Stream 1: D1/CIF(1 ~ 25/30fps)iv).Image Sensor :-1/1.9\" CMOS, Activate Preset/ Scan/ Tour/ Pattern if there is no command in the specied periodv).Lens Type :-Powerful 30x optical zoom/ Fixed focal/Vary focalvi).Lens :-1/1.9” 4 Megapixel CMOS,4XDigital Zoom,10X optical Zoomvii) lmage Settings :-Max. 25/30fps@1080P and 50/60fps@720P Compression,Colour,Brightness, Sharpness,Contrast,White Balance,Exposure control,Back light compensation ,Auto tracking,Pre-set tour settingsviii).Panning Range :-Pan: 0° ~ 360° endless; Tilt: -20° ~ 90°,autoip 180° ix).Tilting Range :-Pan: 0° ~ 360° endless; Tilt: -0° ~ 90°,autoip 180° ix).Tilting Range :-Pan: 0° ~ 360° endless; Tilt: -0° ~ 90°,autoip 180° x) Manual Control Speed :-Pan: 0.1° ~200° /s; Tilt: 0.1° ~120° /sxi).Image settings :- Auto xii).Audio :-one way audio Supported Storage/Built in microphone xiii).Protocol :-NETWORKProtocols IPv4, IGMP, ICMP, ARP, TCP, UDP, DHCP, PPPoE, RTP, RTSP, RTCP, DNS, DDNS, NTP, FTP, UPnP, HTTP, HTTPS, SMTP, 802.1x xiv).Security :-IP Address Filtering, output, Access Policy,ARP Protection, RTSP Authentication, User Authentication xv) Operating Conditions :-Wide temperature range: -40°C to 60°C (-40°F to 140°F) xvi ) Casing :-Metal ,IP-66xvii) Minimum illumination :- Colour : 0.5 lux,B/W :0.1 lux(at30 IRE)
76264ch Network Video Recorder-Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution,Two independent HDMI outputs, one HDMI output of 4K resolution,1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG,Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant,Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB at least1 × USB with3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer.
763Supplying, erecting,testing and commissioning of 4 TB Capacity internal SATA HDD
764Supplying, erecting, Commissioning & Testing Screen (108 Cm) /43 Inchpecifications General o Screen Size : 108 cm (43) • Screen Type : LED • HD Technology & Resolution : Full HD TV, 1920 x 1080 • HDMI : 3, USB : 1 • Launch Year : 2018 onnectivity Features : HDMI, 2 Side : USB o 1 Side Video Features • Contrast Ratio : Mega Contrast (Static) • Picture Engine : Hyper real • View Angle : 178 Degree • Panel Type : A+, Digital Noise Filter : Yes • LED Display Type : Direct • Aspect Ratio16:09 • Refresh Rateo 60 Hz • Other Video Features o PMI 300: Clarity, Color, Contrast, Active Noise Reduction, Dynamic Color Enhancer o Picture Mode: 8 Modes (Vivid, Standard, APS, Cinema, Cricket, Game, Expert1, Expert2) o Picture: JPEG, Digital Noise Reduction, Movies Support in USB Mode, MPEG H.264 Decoder o Response Time: 6.5 ms, Still Image, Wide Color Enhancer (Plus), Film Mode, Cricket mode Audio Features • Number of Speakers : 2 • Speaker Type: Down Firing with Bass Reflex • Sound Technology : Dolby Digital Plus • Speaker Output RMS : 20 W Warranty • Warranty Summary : 1 Year Comprehensive and 1 Year Additional on Panel
765· 13 Passenger Lift (G+2 Floor )Rated capacity :- 13 Passenger/884Kg
766· Floors :-G+2 floor 3 Stops / 3 Landings)
767· Travel :-9 to 10.2 mtrs
768· Location of Lift Machine:- MR/MRL
769· Rated speed :- 1.0mps VS
770· Car/Landing door clear opening of 900 mm wide x 2000 mm high
771· Clear Carsize of..1300....mm wide x .1350.....mm deep x2250mm high
772· Lift shaft available having clear size of2500 mm wide x 1900 mm deep,1500 mm Pit depth, 4250 mm Overhead.
773· Doorstype :- COPO/TOPO Doors with framemade from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory).
774· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.
775· COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor.
776· LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings.
777· Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor andtravel direction protection, protection for phase loss at input or outputetc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility,auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength,copper wire forpower & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class.
778· ARD complete with necessary SMF VRLA batteries.
779· Fireman controller having fireman switch at fire Landing.
780· CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proofDome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge.
781· Lift Machineof Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength.
782· Other mechanical parts such as \"T\" section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work.
783· Minor civil work such as alteration work if any necessary for erection of landing door frames and it\"s accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixingsteel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT.
784For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP\"s with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. ( Rs.141837/-x 1 Nos = 141837/-)
785For Full Collective control system, add as below. For Lift travellingabove First floor & up to Sixth floor( Rs. 27340 /- x 1 nos.= 27340 /- )
786For additional 2MP Camera along with necessary accessories at Home Landing, add as given (3 Additional floor Rs.13460 /- X 1 Nos= Rs. 13460 /-)
787Total =( 1386712 + 141837 +27340 +13460=Rs. 15,69,349 /-)
7881) · General: - Job includes entire procedure of obtaining all necessary erection permissions & \"License to Work the Lift\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge.
7892) · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
790Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 1600 to 1800 LPM at 70 to 55 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 30kW or ofsuitable kW capacity for manual/automatic operation and consisting of following:(a) Horizontal type, single stage, centrifugal/split casing pump ofcast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirre cage induction motor, TEFC, synchronous speed 3000 RPM, suitablefor operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire redcolour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, asper specification no. FF-MFP/SSC/EP
791Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following : (a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
792Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual /automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS-325. (c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete,as per specification no. FF-MFP/BP
793Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 1600 to 1800 LPM at 70 to 50 m head driven by 45 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520. (b) Water cooled with radiator, diesel engine conforming to relevant IS standardcomplete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine,exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for autostop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
794Supplying, erecting, testing & commissioning of fire pump control panel (FCP) of cubical construction, floor mounted type, fabricated from minimum 2 mm thick CRCA sheet, compartmentalised with hinged lockable doors, with enclosure protection class IP54, duly powder coated or painted with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003), cable alley, interconnection with suitable size solid copper busbar strip of adequate size for all power connections having switchgears and accessories, mountings and internal wiring with adequate size copper conductor cable, earth terminals, numbering etc. complete in all respect, suitable for satisfactory operation of main fire pump and jockey (pressurisation) pumps (1working+1standby) with necessary accessories, wiring & cabling along with allied accessories with following incoming and outgoings, suitable for automatic & manual operation on 415V, 3 phase, 50Hz ac supply as per specifications the capacity of electric motor driven pump are as follows a. Main fire pump(MFP) having capacity of 22kW 1no (1 working) b. Jockey pump(JP) capacity of suitable capacity 2 nos(1 working +1 standby, alternate run per start in auto mode) comprises of the following features & switchgears: 1. Main incomer FP SFU having rotary handle with HRC fuses of suitable rating. 2. Electrolytic grade copper strips for busbar of suitable sizes for main incomer and branches to motor SFU\"s, starters & outgoing terminals with necessary accessories like stainless steel nut bolts with spring washers for connections, mounted on required no of epoxy or porcelain support insulators of suitable ratings etc. 3. Individual pump TPN SFU having rotary handle with HRC fuses of suitable rating. 4. Digital voltmeter & ammeter & RYB indicating lamps & push buttons & SPP, O/L & phase reversal protection with emergency stop switch. 5. TPN SPD 100kA Type 1 +2 tested. 6. Required pressure transducer with pressure indication on panel with cabling required for monitoring & automatic operation of fire pumps. 7. System controller to control operation of main electric fire pump, jockey (pressurization) pumps in sequence with interlocking for operation of pumps as per specification with automatic/manual operation with selector switch & alternate run of standby Pumps consisting of relays, timers. sensors, annunciation window for fault indication, complete as per specification. 8.Suitable capacity electric motor starters for all individual pumps with necessary push buttons & indications. 9. Siren of required capacity to be activated when main pump starts & allied accessories as per requirements of local CFO or as directed by engineer in charge. 10. Danger board as per IS. 11. Spare HRC fuses minimum 2nos of each individual rating with required bakelite fuse holder for main & jockey fire pumps MFP=(1working), JP = (1working+1standby, alternate run per start in auto mode) complete panel, as per specification no. FF-MFP/ECP
795Note A1 Rs 14277/- for main pump of 30KW. D add Rs.68381/- for diesel engine fire pump.)
796Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 20 HP consisting of Star Delta starter having relay range 13-21 Amp, S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
797Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessary fittings complete as per specification no. FF-PP
798Supplying and installing G.I.pipe above ground of ‘C’ class ERW of size 32 mm diawith necessary fittings asper specification no. FF-PP
799Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessary fittings complete as per specification no. FF-PP
800Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
801Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP
802Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP
803Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings complete as per specification no. FF-PP
804Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.
805Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
806Supplying and erecting 100 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
807Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV
808Supplying and erecting 100 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
809Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
810Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
811Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
812Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
813Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
814Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
815Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
816Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
817Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
818Supplying and installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT
819Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
820Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
821Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/ NZ
822Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FBC
823Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
824Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
825Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
826Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
827Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
828Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
829Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\"x6\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
830Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FFSPR.
831Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.
832Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
833Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
834Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
835Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
836Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
837Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
838Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
839Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
840Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
841Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
842Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
843Carrying out core cutting of size 3\" to 5\" dia x 15\" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
844Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
845Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
846Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
847Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
848Supply, fixing & testing of illuminated LED Exit signages with battery backup upto 8 hrs at prominent place for identification in case of emergency.
849Supply, installation, testing and commissioning of 150 mm dia. Installation Wet Alarm Valve with Water Motor Gong, Pressure Gauges, Test Lines with Ball Valves with necessary GI (H) piping with threaded fittings of required sizes complete.
850Providing and fixing UL/Fm listed SS unbraided flexible pipe 1000/1200mm long with accessories complete with all accessories specified in technical specifications(Size=15B)
851Fire door : Providing , supplying , fabricating & Installing of 120 minutes fire rated Hinged Metal Fire Door 1200x2100 mm of make Rated Un insulated Single 50 mm thk with honeycomb infill Sgl/Dbl Rbt 143 x 57 mm frame straight with anchor fastners frame 1.0 & shutter 0.9 mm, Powder coated to RAL Shade , SFP SS Ball Bearing 4\" X 3\" X 3 mm Hinge For Steel , Dorset Sash Lock Body EC Dorset Both Side Key 70 mm Dorset SS Mortise/Lever Handle on Rose 22 mm dialngersoll Rand Briton 121.NCE.SES Door Closer Size 3 with Standard Arm, Sprayed Silver Finish with all fixtures & fasteners including all Taxes and as per drawing directed as per Engineer - in - charge . fire rated Hinged Metal Fire Door 1200x2100 mm
852Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 -28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
853Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
854Supplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP
855Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP
856Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300µA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/ SD .
857Supplying, installing, testing and commissioning of intelligent addressable thermal/ heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from - 20°C to 38 °C for fixed-heat and rate-of-rise type detectors whereas 0°C to 90°C for high heat type detectors, in built isolation mode, suitable for industrial/ kitchen/ boiler room etc. with 3 years equipment replacement warranty, IS : 2175-1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD.
858Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP.
859Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM
860Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM
861Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM
862Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH.
863Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
864Supplying, erecting, testing and commissioning 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC
865Supplying, erecting, testing and commissioning stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector, stereo jack complete as per specification no. FF-PA/MIC
866Supplying, erecting, testing and commissioning rust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete.
867Supplying, erecting, testing and commissioning of 2 core shielded cable complete as per specification no. FF-PA/MCC
868Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.
869Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit.
870Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With PVC accessories on wall /ceiling as per specification No: WG-MA/CON..
871Supplying, installing, testing and commissioning of120 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 300 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnectingwires / cables up to solar ON GRIDinverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card / chip for 5 yearsincluding net charges for RMS System, complete up to net meter Installation and export to the grid with 5 year ON-SITE warranty andfully comprehensive maintenance contract as per Specification no. ESD-RT-ONG.( 100+20=120 kwp. ) ( Rs. 4834619 + (58720 x 20 ) ( 4834619 + 1174400 ) = Rs. Rs. 6009019 /-
872Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.
873SupplyinganderectingAC three phase LT CT multifunctionnet meterDLMS compliance of accuracy class 0.5, 3 x 240V, 50Hz,with backlitLCD display, optical port& RS 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power)with wiring connections and mountinghardwareonprovidedpanelscompletewith calibration certificate from manufacturer.
874Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core120sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
875Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP
876Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
877Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).
878Supply, Installation, Testing and Commissioning of CCSD-DL; CCS 1000 D Discussion Device Long; Frequency response: 200 Hz to 12.5 kHz; Headphones load impedance: > 32 ohms < 1k ohm; Loudspeaker nominal output: 72 dB SPL; Height with microphone (Horizontal): 130 mm (5.1 in); Weight Approx. :1 kg (2.2 lb); Mounting: Tabletop (portable or fixed); Material: (base) Metal ZnAl4
879Supply, Installation, Testing and Commissioning of CCSD-CURD; CCS 1000 D Control unit Recorder DAFS; Mains voltage: 100 to 240 VAC ± 10%; Power consumption: Max. 0.6A (100-VAC) to 0.2A (240-VAC); DC supply to Discussion Devices: 24 V ± 1 V (current limited); Number of Discussion Devices per Control Unit: Max. 40 devices per trunk connector; Discussion Device loudspeakers volume control: 15 steps of 1.5 dB (starting from -10.5 dB); Limit threshold level to unit: 12 dB above nominal level; Gain reduction due to number of open microphones (NOM): 1/SQRT (NOM); Nominal input: (85 dB SPL) < 0.5%; Max. input: (110 dB SPL) < 0.5%; XLR nominal microphone input: -56 dBV; XLR max microphone input: -26 dBV; RCA nominal input: -24 dBV (+/- 6 dB); Sample rate: 44.1 kHz; RCA max input: +6 dBV
880Supply, Installation, Testing and Commissioning of Plena Booster Amplifier 480W:- Power supply; Input Voltage: 230VAC ±10% at 50/60Hz or 24VDC; Inrush Current: 19A at 230 VAC, 30A at 24 VDC; Performance; Rated Output (RMS): 480W; Power reduction on backup power: -1 dB; Frequency response: 60 Hz to 18 kHz (+1 / -3 dB at -10 dB ref. rated output); Distortion: <1% at rated output, 1 kHz; S/N (flat at max volume): > 90 dB; Power consumption; Max power consumption: 1600 VA; Connector: 3-pin XLR, balanced; Sensitivity: 1 V; Impedance: >20k ohm; CMRR: >25 dB (50 Hz to 20 kHz); Gain: 40dB; Loudspeakers outputs: 3x; Priority only (from input 1): 100V/70V internally selectable; 100V/70V; Music (non-priority) only: internally selectable.
881Supply, Installation, Testing & Commissioning of LA2-UM-40-D/L-IN Metal Column Speakers; Maximum power : 60W; Rated power (PHC) : 40W; Sound pressure level at rated power / 1W (1kHz, 1m) : 93/106 dB (SPL); Effective frequency range (-10dB0 : 120 Hz to 15.3 kHz; Horizontal opening angle at 1 kHz / 4kHz (-6dB) : 201o/129o; Vertical opening angle at 1 kHz / 4kHz (-6dB) : 55o/14o; Rated input voltage : 100V; Dimensions (LxWxD) : 651x140x110 mm (25.6x5.5x4.3inches): Connector : 1x4 way push type.
882Supply, Installation, Testing & Commissioning of R300-HD-A; Cordless Handheld Microphone; Handheld Wireless Mic with Cardiod polar pattern, Dynamic microphone ,frequency response 80Hz-18kHz,RF sensitivity < 1.0 Uv, Image rejection>55dB, Dynamic range >95dB and receiverhaving 30 or morechannels possible, S/N ratio >100dB A, dynamic range >95db B, distortion <1 %,frequency band:618-634MHz,more than 12hrs battery life with AA battery. The transmitter & receiver should be of metal body.
883Supply, Installation, Testing and Commissioning of LBB1968/00; Plena Feedback Suppressor; Uses a powerful DSP with a patented algorithm to suppress acoustic feedback using an echo-cancellation & de-reverberation algorithm; Frequency response 125 Hz to 15 kHz; Distortion <0.1 % @1kHz;S/N > 90 dB; Signal delay <11 ms
884Supply, Installation, Testing and Commissioning of CMS600-3; 8 ChannelMixer; Compact Mixing System with Digital Audio interface; 4 input channel & 4 output channels; AD/DA conversion 24-bit; USB 2.0 PC Interface, MIDI interface, OLED display; 100 Digital effects presets – at-least 20 user preset available; 4x Mic/Line + 2x MIC/Line-Mono/USB-Stereo + 2x Stereo-Line; 9 band master stereo equalizer; THD(at1kHz)<0.005%; Frequency response(-3dB) :20Hz to 70kHz; Crosstalk<-80 dB,CMRR (at 1kHz)>80dB; Equivalent input noise:-130dBu A; Max level Mic inputs:+12 dBu.
885Supplying,erecting, testing and commissioning of 1.5 sq. mm speaker wire complete.
886Supplying and fixing 17U floor mount rack (Dimension-DxWxH – 800x600x954 mm) as per specification No. WG-NAS/RAK
887Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
888Supplying & erecting HRC fuse cartridge 415V, 200A
889Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete.
890Supplying and erecting GI sheet 1.6 mm (16 SWG) caution board of size 200 x 150 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for medium voltage (415 Volt) installation with compliance to IS 2551-1982
891Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.
892Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
893Supplying anderectingLT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power completewithzeroadjustment&testcertificatefrom manufacturer erected on providedM.S. box and connected to CTs.
894Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
895Supplying, erecting& terminatingXLPE insulated unarmoured cable 1100 V 1 core120 sq. mm. aluminiumconductor completeerected with lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
896Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL
897Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
898Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT
899Supplying & laying (including excavation) reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
900Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ
901Supplying & erecting 100 x 50 x 6 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4 m wide DP structure and erecting on DP with 50x6mm clamp complete as per specification no. OH-PL/BKT
902Supplying and erecting V cross arm with ISM channel of75x40x6mmfor 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height ofV cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA
903Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flangechannel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA
904Supplying and erecting bracket for guarding of HT OH Line, madefrom channel iron 1600mm in lengthand 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA
905Supplying and erecting ACSR conductor of size 6/1-2.59 mm complete. (Weasel) (127.7 kg/km)as per specification No. OH-CON/ACSR
906Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws,G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and poleclamps duly erected in provided cement concrete foundation complete.
907Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete asper specification no. OH-INS/PN
908Supplying and erecting distribution class, 11 kV thyrite type lightening arrester with nut bolts, on provided MS channel as per specification no. OH-INS/LA
909Supplying and erecting pole clamp made from 50x6mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete.
910Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP
911Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP
912Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint with joints required as per specification no EA-EP. (40 X 5 mm. strip ) (4.5 mtr. @ 0.538 kg/mtr. = 2.42 kg say 2.5 kg.)
913Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
914Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, copperwoundNon-sealed transformerdelta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50 ? by the resistance methodin winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.
915Supplying and erecting 11 kV outdoor type gangoperated air break,triple pole switch200 A capacitywith3postpin type insulator per phase, mounted in horizontalor vertical position with necessary channelson providedcrossarmwithadequate length of \"C\" class G.l. pipe for operating handle erectedonextendedsquareshaft. Theoperatinghandle provided with lock and key at suitable heightfrom ground level with necessary clamp.
916Supplying and erecting, 11 kV outdoor type drop out fuse with insulator complete with fuse holders, fusebarrelwithmetalfitting,fuse elementmounted onM.S.channel with working currentof15A capacity complete erected on provided cross arm.
917Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.).
918Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. (0.8 X 0.65 X 0.9 X 5 = 2.34 cum.)
919Providing and making second class Burnt Brick masonry with conventional /I.S. type bricks in cement mortar 1:6 in foundation sand plinth of inner walls /in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.(0.8 X 0.65 X 0.9) - (0.60 X 0.45 X 0.9) X 5 =1.125 CuM)
920Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete of medium duty (100 Kilogram).
921Makingcement concrete foundation including excavation(60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal,45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)
922Making cement concrete foundation including excavation(60x 60x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metalwith necessary curing and finishing complete.(for stay).
923Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose). (0.6X0.45 X 0.1 X 5=0 .135 CuM )
924Supplying and erecting ISI mark GI pipe 100 mm dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.

AI Tender Summary

OUR REF NO 42489657
AUTHORITY Government Departments
TENDER VALUE 28.71 Crore
LAST DATE 14-03-2024
Authority
Authority Name Public Works Department
Work Description Construction Of Central Administrative Building At Bhatkuli Dist. Amravati (Including Electrical Works)
Basic Detail
Tender No Amt/79/1/spdn2/778/14.02.2024
Bidding Type Tender
Location
City bhatkuli
State Maharashtra
Key Dates
Publish Date 23 Feb 2024
Submission Date 14 Mar 2024
Open Date 18 Mar 2024
Finance
Tender Value 28.71 Crore
Tender Fee 3540
EMD 14.36 Lakhs
Exemption Not Available
Document List
c11533c8-b118-4084-bc85-b25034ee65b7.html
BOQ_1774713.xls
SBDAdmnBuildingBhatkuli28_1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 23, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 14, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 18, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

c11533c8-b118-4084-bc85-b25034ee65b7.html

xls

BOQ_1774713.xls

pdf

SBDAdmnBuildingBhatkuli28_1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders