Tender For Additional/Alternator And Rehabilitation Of Otm Bldg No. T-66, T-67, T-68 And T-69 At Mil Stn Sangrur Under Ge (South) Patiala, sangrur-Punjab

Military Engineer Services-MES has published Tender For Additional/Alternator And Rehabilitation Of Otm Bldg No. T-66, T-67, T-68 And T-69 At Mil Stn Sangrur Under Ge (South) Patiala. Submission Date for this Tender is 16-03-2024. Mobile Generator Tenders in sangrur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42480010
Tender For Additional/Alternator And Rehabilitation Of Otm Bldg No. T-66, T-67, T-68 And T-69 At Mil Stn Sangrur Under Ge (South) Patiala
Open Tender
Indian
Punjab
sangrur
16-03-2024

Tender Details

Tender For Additional/Alternator And Rehabilitation Of Otm Bldg No. T-66, T-67, T-68 And T-69 At Mil Stn Sangrur Under Ge (South) Patiala

Key Value

Document Fees
INR 500 /-
EMD
INR 80700.0 /-
Tender Value
Refer document

BOQ Items

Name of Work :ADDN/ALTERATION AND REHABILITATION OF OTM BLDG NO. T-66, T-67, T-68 AND T-69 AT MIL STN SANGRUR UNDER GE (SOUTH) PATIALA
Sl. No. Item Description
1M&L for brick work in cement mortar (1:6) using sub class "B" bricks staight or curved on plan exc 6.0 m mean raidus complete all as specified and directed by Engr-in-Charge.
2Demolition of cement concreteun -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified and directed by Engr-in-Charge.
375 mm thick PCC (1:3:6) type C1 (using 20mm grade aggregate) as in plinth protection, path etc finishing the surfaces even & smooth w/o using extra cement complete all as specified and directed by Engr-in-Charge.
4M&L for Baroda Green marble, machine cut as in shelves/steps./cills/Jambs/skirting/border only in tiles flooring and the like works and flooring etc 15-16 mm thick incl bull-nose the exposed sides/lengths, set and jointed in cement slurry over & incl screed of 15mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab for fixing on concrete surfaces or with suitable adhesive for fixing on un-polished kota stone slabs incl rubbing, cutting and mirror type granite polishing and incl dismanting/demolition complete all as specified and directed by Engr-in-Charge.
5Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust, etc complete all as specified and directed by Engr-in-Charge.
6Providing machine cut Kota stone slab flooring of Size 550x550x20 mm thicklaid over 15 mm thick cement mortar 1:4 screed bed laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing to mirror finish complete to be fixed in any position as described andcomplete all as specified and directed by Engr-in-Charge.
7Providing machine cut Kota stone slab on vertical surfaces as in skiting /dado of size 550x150x20 mm thick laid over 10 mm thick plasterin cement motar 1:4 and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing to mirror finish complete to be fixed in any position as described and complete all as specified and directed by Engr-in-Charge.
8Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified and directed by Engr-in-Charge.
9Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqmincl cutting holesand making good reqd shape for hold fast block for new frame complete all as specified and directed by Engr-in-Charge.
10Providing and fixing factory made extruded aluminium casement windows with 50 micron powder coating with provision for desert cooler,doubled panelled anddouble shutters consisting of frame and mullion of 101.60 X 44.45 X 1.29 mm and shutters made of 63.5 X 31.75 X 1.29mm and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and including 5mm thick glass in front shutters and stainless steel wire gauge 0.36mm dia and 1.40 aperature in inner shutters complete fixed in all respect as specified including supply and fixing following items :- (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm -2 Nos per leaf. (b) Powder Coated Aluminium Tower Bolt 150mm long - 2 Nos per leaf. (c) Powder Coated Aluminium Handles 150 mm - 1 Nos per leaf.
11Taking down cement plaster on walls built in cement mortaretc including racking out joints, hacking for key.Scrubbing down with water etc. complete all as specified and directed by Engr-in-Charge.
12Rendering 15 mm thick in cement mortar 1:4 , mixed with water proofing compound, on brick or concrete surfaces, trowelled to even and smooth finish without using extra cement with WPC paid and measered separetely complete all as specified and directed by Engr-in-Charge.
13All as per srl item hereinbefore but 10mm thick in CM 1:6 finishing even and smooth without using extra cement.
14M&L for applying two coats of oil bound distemper over one coat of primer over a coat of 2mm thick wall care putty on new plastered surfaces of walls including preparation of newsurface complete all as specified and directed by Engr-in-Charge.
15M&L for complete removal of existing treatment of wall and applying two coats of distemper oil emulsion over a coat of 2mm thick wall care putty filling complete all as specified and directed by Engr-in-Charge.
16M&L for preparation of new plastered surfaces of ceiling and applying three coats ofwhite wash all as specified & directedby Engineer-in-Charge
17M&L for preparing existing treated surfaces of external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc including cornices and applying two coat of cement base paint @ 5 sq.m/kg/1 coat by using following brands of cement based paint by roller complete all as specified & as directed by Engineer-in-Charge.
18M&L for preparation new plastered to walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc including cornices and applying two coat of cement base paint @ 5 sq.m/kg/1 coat by using following brands of cement based paint by roller over a coat of priming coat complete all as specified & as directed by Engineer-in-Charge.
19Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engr-in-Charge.
20Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engr-in-Charge.
21S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mps as in roof covering fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
22S/F Pre-painted galvalume aluminum zinc coating GI based plainsteel sheet 0.50 mm thick of any colour having tensile strength of 550 Mps as in roof covering fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
23S&F steel works in tabular trusses including special shaped washer etc complete using FRW or induction but welded tubes confirming to grade IS- 1161-1979 complete all as specified and directed by Engr-in-Charge.
24S & F for bands, straps, supports or stays for rainwater, ventilating pipes, incl bolts, if reqd : hooks (say), heavy, for large gates, hook and pintle hinges : large hasps and staples; chains; hand made sliding bolts ; clamps; hold fasts; waal ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts,; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-Charge.
25M&L for preparation of new painted surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described andapplying twocoat of synthetic enamel paint over a coat of redoxide on new surfaces in any tint complete all as specified and directed by Engr-in-Charge.
26S&F stainless steel tubing 202 grade of 25mm dia mild steel chromium plated 1.0mm thickness as in curtain rod complete including S&F 02 nos stainless steel brackets fency type stop etc in repairs complete all as specified and directed by Engr-in-Charge. Note :- For the purpose of measurement and payment running length of curtain rod only shall be considered.
27Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets complete all as specified and directed by Engr-in-Charge.
28S&F for4 mm thick of size 600x600mmHSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer boardE-Board Classic to be fixed aluminium grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mmduly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and directed by Engr-in-Charge.
29S&F anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed by Engr-in-Charge.
30S&F for anodised aluminium door shutter, aluminium section weighting 0.55 kg/m including necessary joining, cleats,glazing clips,rubbber neoprene, packing headls 2 nos in each door hinges anodised aluminium snap beading screw etc including mortice lock with minimum three sets of key complete all as specified and directed by Engr-in-Charge.
31S&F for aluminium (extruded section) bodydoor closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engr-in-Charge.
32S&F Sheet glass 5.8 mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified and directed by Engr-in-Charge.
33Excavation in post holes (or similar holes) each n.exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed by Engr-in-Charge.
34M&L for PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation complete all as specified and directed by Engr-in-Charge.
35Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core etc.. to store and rubbish not exc. 50m, built in cement motar or cemet lime motar complete all as specified and directed by Engr-in-Charge.
36M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed with grey pigment cement and pigment floors with grey pigment cement and pigmentover 15 mm thick screed bed in cement motar 1:4 complete all as specified and directed by Engr-in-Charge.
37Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants regulators Tube fittings and other Kits & fittings/conduitfromsurface /wall . Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location and complete all as specified and directed by Engr-in-Charge. (Note :- Serviceable fitting / fixtures will be reused in the work as directed by Engineer- in-Charge)
38Taking down un-serviceable main switch, DB’s insulators, DB for MCB etc of any type and any capacity and further disposal including making good the disturbed surface and matching the colour of wall with the existing colour wash / paint / distemper wherever required (as per the existing ) complete all as specified and directed by Engr-in-Charge.
39M&L for point wiringwith FRLSPVC insulated unsheathed multi-stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawninand including rigid non metallic concealed PVC Conduit of suitable size (not less than 20 mm) on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes(Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLSPVC insulated unsheathed stranded copper conductor 1.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed by Engr-in-Charge, for the following :-
40One light/fan point controlled by one 1-way switch
41One3/5 pin socket outlet, 5 Amp on independent board
42One3/5 pin socket outlet, 5 Amp on same board
43M&L for point wiring with FRLSPVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawninand including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes(Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLSPVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified anddirected by Engineer in Charge.
44Dismantling / Taking down existing unserviceable sub main wiring from batten / conduit of any size all as directed. Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location and complete all as specified and directed by Engr-in-Charge.
45M &L for sub main surface wiring with PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through concealed rigid nonmetallicPVC conduit of suitable size (Not less than25mm dia)inwall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly includingmakinggoodthedisturbedpotionofwall complete all as specified and directed by Engr-in-Charge. (Note :- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length)
46Switch Modular type, 6 Amp, 240 Volts , one way complete fixed as in repair complete all as specified and directed by Engr-in-Charge.
47Switch Modular type, 16 Amp,240 Volts , one way complete fixed as in repair complete all as specified and directed by Engr-in-Charge.
48Socket outlet, Modular type, 6 Amp complete fixed as in repair complete all as specified and directed by Engr-in-Charge.
49Socket outlet, Modular type, 6&16 Amp complete fixed as in repair complete all as specified and directed by Engr-in-Charge.
50Fan regulator, modular type electronic step type complete fixed as in repair complete all as specified and directed by Engr-in-Charge.
51S&F ceiling rose surface bakelite two to three terminal 65x50 mm. complete all as specified and directed by Engr-in-Charge.
52S&F in replacement Tube light fittings LED type 1x20 Watt4 ft long incl LED tube rod and incl 3 core flexible wire 0.75 Sqmm copper cable complete all as specified and directed by Engr-in-Charge.
53Supply & fix LED bulk head ,10 W complete all as specified and directed by Engr-in-Charge.
54S&F MCBDB SPN8 Waywith acrylic double door complete all as specified and directed by Engr-in-Charge.
55S&F including flushing in wallMCB distribution board verticalTPN 4 way 415 Volts AC double door type sheet steel phosphotised powder painted with bus bar neutral earth barincluding provision of MCB TPN, FP 100 Ampconforing to IP 43as incomer complete all as specified and directed by Engr-in-Charge.
56S&F MCCB 4 pole 100 Amp 415 voltwith breaking capacity of 16 KA complete all as specified and directed by Engr-in-Charge.
57S&F MCB SPN 240V 40 Amps C series 10 KA complete all as specified and directed by Engr-in-Charge.
58S&F MCB SP 240V 6 to 32 Amps C series 10 KA complete all as specified and directed by Engr-in-Charge.
59S&F Sheet metal enclosure factory made of size 20cm x 25cm x 12.5 cm deep box made out of 2mm thick ms sheet with double door with locking arrangement , epoxy power coated holes drilled for cable entries suitable for accomodating electric energy meterincluding brick/cement works as per site requirementincludiing flushing the box in walll and making good the disturbed portion of wall /surface complete all as specified & directed by Engr in charge.
60Supplylaying jointing cable XLPEinsulatedPVC shetahtedstrip wire armoured1100 volt3.5 core 95 sqmm multi stranded aluminiumconductor laid in trenches/wall/ducts etc including necessary fixing arrangement such as cable lugs glands etc completeafter removing/taking out extg unsvcable to the entire satisfaction of Engr in Charge.
61Supplylaying jointing cable XLPEinsulatedPVC shetahtedstrip wire armoured1100 volt3.5 core 50 sqmm multi stranded aluminiumconductor laid in trenches/wall/ducts etc including necessary fixing arrangement such as cable lugs glands etc completeafter removing/taking out extg unsvcable to the entire satisfaction of Engr in Charge.
62Excavation in trenches n.exc 1.5 mtr deep and n.exc 1.5 mtr wide getting out soil complete all as specified and directed by Engr-in-Charge.
63Returning filling in including spreading leveling, watering and well ramming in layers complete all as specified and directed by Engr-in-Charge.
64Removing excavated soil to a distance not exc. 50 mtr and depositing where directed complete all as specified and directed by Engr-in-Charge.
65Supply and spreading dry sand in trenches for cushioning of cable complete all as specified and directed by Engr-in-Charge.
66Supply and laying well brunt bricks sub class ‘B’ of size 25 x 12.5 x 7.5 cm complete all as specified and directed by Engr-in-Charge.
67S&F HDPE pipe of size50mmdiacompleteallas spcifed& directedby Engr-in-Charge.
68M&L for earthing complete withgalvanisedsteel earth plateelectrode 600x600x6mm thick burieddirectlyin ground(earth pitnot less than2 mtr deep belowground levelwith top edgwof the platenot less than 1.4 mtr belownormal ground level, connected earth wire 4 sqmm by means ofbolts nutscheck nutsand washersof galvanisediron or steelall as shownin electrical plateNo 5 connectedto earthingtest pointall as specifiedor indicated includingPCC pitin PCC(1:3:6) type C-1 cast ironframe50mm thickpre castRCC(1: 1 1/2:3)nominal mixcover slabreinforcedwith 8 mmdia mild steeldeformed bar15cc and suitable handleof 10 mm Diaround barincluding necesaryexcavationearth workin soft/loose soiland disposalof spoilto a distancen.exc 50m and funnelwithwatering pipewire meshcopper lugsetc GI protectionpipe of size 15 mm boreincluding testing completeall s specified & directed by Engr in Charge.
69Supply, installation, commissionningand testing of outdoor feeder pillarmade out of CRCA sheet 3.0 mm thick vermin proof factory made CPRI approved, withcopper bus bar of capacity 600 Amps for 3 phase and neutralwith nessary angle iron 50 x 50 x 6 mm support frame including two coats powder painting over a coat of red oxide primer and grout in PCC complete all as specified and directed by Engr-in-Chargecomprising of the following. (A) inCOMinG : (a) MCCB 400 Amps Four pole 35 KA-01 No (b) indicator lamps RYB LED type(Set of Three)-01 No (B) OUTGOinG : (a) MCCB Four Pole 100 Amps 25 KA-03 No (b) Wiring of above accessory with suitable size of copper conductor cable Note :-(i) All MCCBs / instruments / MCBs / Bus Bar shall be housed in a separate housing with on- off latches in the housing. (ii) Space for provn of one extra MCCB should be provided in the panel.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail