Tender For Repair And Maintenance Of Air Conditioner, Water Coolers And Cooling Appliances Incl Connected Items And Repair To Ceiling Fan , Exhaust Fan, Geyser, Electric Meter And Connected Works In Otm Md Accn For Various Units At Akhnoor Of Under Ge, akhnoor-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Air Conditioner, Water Coolers And Cooling Appliances Incl Connected Items And Repair To Ceiling Fan , Exhaust Fan, Geyser, Electric Meter And Connected Works In Otm Md Accn For Various Units At Akhnoor Of Under Ge. Submission Date for this Tender is 16-03-2024. Air Conditioner Tenders in akhnoor Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

42479984
Corrigendum : Tender For Repair And Maintenance Of Air Conditioner, Water Coolers And Cooling Appliances Incl Connected Items And Repair To Ceiling Fan , Exhaust Fan, Geyser, Electric Meter And Connected Works In Otm Md Accn For Various Units At Akhnoor Of Under Ge
Open Tender
Indian
Jammu And Kashmir
akhnoor
16-03-2024

Tender Details

Repair And Maintenance Of Air Conditioner, Water Coolers And Cooling Appliances Incl Connected Items And Repair To Ceiling Fan , Exhaust Fan, Geyser, Electric Meter And Connected Works In Otm Md Accn For Various Units At Akhnoor Of Under Ge ( South ) Akhno

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 26000.0 /-
Tender Value
INR 13 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINT OF AIR CONDITIONER, WATER COOLERS AND COOLING APPLIANCES INCL CONNECTED ITEMS AND REPAIR TO CEILING FAN , EXHAUST FAN, GEYSER, ELECTRIC METER AND CONNECTED WORKS IN OTM & MD ACCN FOR VARIOUS UNITS AT AKHNOOR OF UNDER GE (SOUTH) AKHNOOR. (SECOND CALL)
Sl. No. Item Description
1M & L for disconnecting electric supply, taking down fan, cealing cable ends, dismantling blades carefully after unscrewing nuts and bolts of ceiling fan of any make from existing position and bringing to AGE E/M store yard for repairs, overhauling, oiling, greasing and cleaning all dusts all as specified and as directed by EIC. complete all as specified and as directed by EIC. Note : Store like ball bearing, gun metal bush, capacitors and canopy required for repair/over hauling shall be measured and paid separately under relevant item of this schedule.
2M & L for painting of ceiling fans (1200 mm/ 1400 mm) complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts including writing of MES Nos in black paint all as specified and as directed by EIC.
3Dismantling of worn out/burnt out ceiling fans 1200 mm sweep and re-winding the ceiling fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut , complete all as specified and directed by Engineer in charge
4Description all as per serial item No 3.00 here in before but for Ceiling fans of 1400 mm sweep.
5Supply and fixing in replacement of ball bearing suitable for ceiling fans of any make, type and size. Make: - SKF, NBC, and TATA
6Supply and fixing in replacement of bush made out of Gun metal suitable for ceiling fans of any make, type and size.
7Supply and fixing in replacement of capacitors 2.5 MFD suitable for ceiling fans of any make, type and size. Make: - Usha, Universal, Tipcon, Epcos.
8Supply and fixing in replacement of canopy suitable for ceiling fans of any make, type and size. Make: - Usha/Khaitan/ Bajaj.
9Suply and replacement of down rod suitable for ceiling fans of any type and size.Make Usha or equivalent.
10Supply and fixing in replacement of clamp with nuts & bolts & locking pin suitable for ceiling fans of any make, type and size. Make: - Usha/Khaitan/ Bajaj.
11Supply and fixing in replacement rubber reels suitable for ceiling fans of any make, type and size. Make: - Usha, Universal, Tipcon, Epcos.
12Supply and fixing in replacement of aluminium blade for ceiling fan of 1200 mm sweep complet all as specified and directed by Engr-in-Charge.
13M & L for hanging the repaired ceiling fan (dismantling as per item No. 1 above) and connecting up including provision of cables from ceiling rose or connector to fan all as specified and as directed by EIC.
14S & F 0-4 step-1, electronic fan regulator flush type on the existing phenolic laminated sheet including taking down the old unserviceable regulator all as specified and as directed by EIC.
15Taking down carefully existing exhaust fans of any make and sizes from wall , cleaning externally, opening for examination and overhauling complete by opening , cleaning of bearing ,stator ,rotor winding , providing new fresh clean proper grade lubricants oil/grease and re assembling after replacement of split/safety pins, MS nuts and bolts , including replacement of old existing flexible cord connected from ceiling rose to fanincluding re-writing MES/ SL No. with black synthetic enamel paint , refixing the same in position complete all as specified and directed by Engineer in charge. Note:-Store like ball bearing, gun metal bush and capacitors required for repair/overhauling shall be measured and paid separately under relevant item of this schedule complete all as specified and directed by Engr-in-Charge.
16Dismantling of worn out/burnt out Exhaust fans 275 mm to 375 mmsweep and re-winding the exhaust fan with the same size of super enamelled copper wire , varnishing with approved quality insulating varnish complete including replacement of split/safety pins, rusted nut ,bolt and washer complete all as specified and directed by Engineer in charge.
17Description all as per serial item No 16.00 here in before but for Exhaust fans of size above 375 mm but up to 450 mm sweep complet all as specified and directed by Engr-in-Charge.
18Supply and fixing in replacement of ball bearing suitable for exhaust fans of size from 275 mm to 375 mm sweep.Make: - SKF, NBC, and TATA.
19Supply and fixing in replacement of ball bearing suitable for exhaust fans of size above 375 mm to 475 mm sweep.Make: - SKF, NBC, and TATA.
20Supply and fixing in replacement of capacitors suitable for exhaust fans of size 275 mm to 375 mm sweep. Make: - Usha, Universal, Tipcon, Epcos.
21Supply and fixing in replacement of capacitors suitable for exhaust fans of size above 375 mm but up to 475 mm sweep.Make: - Usha, Universal, Tipcon, Epcos.
22M & L for painting of Exhaust fans of size 275 mm to 375 mm sweep complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dusts all as specified and as directed by EIC.
23Description all as per serial item No 22.00 here in before but with grey paint for exhaust fans above of size 375 mm to 450 mm sweep.
24Supply and fixing in replacement of louvers shutters complete with nuts, bolts and washers suitable for exhaust fans of size 275 mm to 375 mm sweep complete all as specified and directed by Engineer in charge.
25Supply and fixing in replacement of louvers shutters complete with nuts, bolts and washers suitable for exhaust fans of size above 375 mm and up to 450 mm sweep complete all as specified and directed by Engineer in charge.
26Supply and fixing in replacement PVC Exhaust fan 250 mm sweep with louvers complete all as specified and directed by Engineer in charge. Make :Crompton/Usha/Luminous/Orient Electric energy star
27Supply and fixing in replacement Exhaust fan 300 mm sweep with louvers complete all as specified and directed by Engineer in charge. Make :Make :Crompton/Usha/Luminous/Orient Electric energy star
28M&L for making hole on masonary wall/ Wodden Panel of size suitable for exhaust fan complete incl finishing and making good as per existingall as specified and directed by Engineer in charge.
29Labour only to find out defects and for testing geysers of any capacity of vertical and horizontal geysers for proper functioning by checking the thermostat, heating elements, indication lamps, cable cords and connections, 15 Amps socket and top, inlet and out let water pipes etc complete all as specified and as directed.Note : If any defects observed during testing shall be repaired in respected item of Sch "A" which is measured and paid separately and spares required to be changed shall be measured and paid separately complet all as specified and directed by Engr-in-Charge.
30Supply and fix in replacement of geyser elements I.5 KW as per existing pattern fitted in the geyser all as specified and directed.Make: Toshiba, Comet, Hot max or as approved by Engr-in-charge
31Description all as per item No 30.00 above but 2.0 KW complete all as specified.
32Supply and fix in replacement of lamp indicater red/green all as per site requirement and specified.
33S & F PVC connection with PTMT nuts of length 450 mm as inlet for cold water including taking down the old unserviceable PVC connection pipe complete all as specified and as directed by EIC.
34S & F PVC connection, spirally reinforced with stainless steel wire inside the pipe for outlet hot water pipe connection, with brass nuts at both ends of length 450 mm including taking down the old unserviceable PVC pipe all as specified and as directed by EIC.
35Supply and fixing in replacement of inner tank of 25 ltr capacity of tinned/ copper of approved make all as specified and directedas per site requirement.
36Supply and fix in replacement of inner tank of 35 Ltrs capacity geyser of tinned /copper of approved Make all as per site requirement and as directed.
37Supply and fix in replacement of inner tank of 50 Ltrs capacity geyser of tinned/ copper of approved Make all as per site requirement and as directed or indicated.
38Supply and fix in replacement of glass wool/mineral wool same as (Thermal insulation) for 25 ltrs capacity geyser all as directed.
39All as per item No 38.00 above but for 35 ltr capacity geyser complete all as specified.
40All as per item No 38.00 above but for 50 ltr capacity geyser complete all as specified.
41Supply and fix replacement of thermostat (Thermal cut out) suitable for geyser to be repaired as per approved make and capacity 25/50 ltrs complet all as specified and directed by Engr-in-Charge.
42Supply and fix replacement ofpressure release valve suitablefor 25/50 ltrs capacity geyser of approved make and type all as site requirement.
43Supply and fix in replacement of 3 core multi strandcopper conductor PVC insulated cable 2.5 Sqmm1100 volts grade complete all as specified and directed by Engr-in-Charge.
44S & F switch socket combination multi purpose three pin 5/15 amps flush type on new laminated sheet top cover, 3 mm thick including taking down old unserviceable 15 Amps switch socket combination all as specified and as directed by EIC.
45S & F 3 pin plug top 15 Amps, 240 volts including taking down old unserviceble 3 pin plug top 15 amps all as specified and as directed by EIC.
46Material and labour for painting the geysers of 25 ltr capacity with two coats of synthetic enamel paint white with spray gun including preparation of surfaces area of geyser,filing cavities with filler after cleaning all dust complet all as specified and directed by Engr-in-Charge.
47All as per item No 46.00 above butof 35 ltr capacity geyser complete all as specified.
48All as per item No 46.00 above but of 50 ltr capacity geyser complete all as specified.
49All as per item No 46.00 above but of 50 ltr capacity geyser complete all as specified.
50Replacement of unserviceable heating element of Bajaj Calenta Geyser 2KW, complete all as specified.
51Replacement of unserviceable Thermostat of Bajaj Calenta Geyser all as specified, complete all as specified.
52Supply and replacement of internal water tubing assembly 6/9 holes for 25 Ltr cap geysers including synthetic rubber gasket of suitable size matching with existing holes and tightening all as directed by Engr-in-Charge.
53All as per item No 51.00 above but 35 ltr capacity complete all as specified.
54All as per item No 51.00 above but 50 ltr capacity complete all as specified.
55S&F in replacement ofCeiling fan, mettalic, sweep 1200mm, with BLDC Motor, high speed, inclduing necessary fitting/fixtures such as Hook and clamps etc including connectig wire of suitable size and length from ceiling rose to fan connector, having BEE Star Rating- 5 Star, Rated Power Input in Watt 28±10%, Rated Speed in RPM 345±10%, Rated Air Delivery in CuM/ Min- 220 Minimum, Service Value CMM/W 7.85 Minimum No of Speed 5 , Insulation Class- E, Temperature Rise @ Rated Voltage 25 degree Celcius (Max) by winding resistance measurement at an ambient 30 degree Celcius, High Voltage Test Withstands 1.5KV, Insulation resistance Above 2 M?, Type of Ball Bearings Single row deep groove ball bearings of 6202 sizes Top &Bottom Cover should be of aluminium, Type of Lubricant Used Lithium Based – Shell Alvania RL3, Material of Blade Aluminium, BEE Certification, Material of Canopies- Polypropylene, complete all as specified and as directed. Make: Crompton Greaves/ Usha / Orient Electric energy star Note: Old Ceiling fan taken out from the existing opening and shall be deposited at Store Yard of MES and shall be the property of Deptt.”
56S&F in replacement ofWater heater storage type (geyser), wall hanging, capacity 25 Litres, Energy saving high density PUF insulation, BEE rating Five (5) Star, 230 Volts, single-phase, 50 Hz AC, rated power input not less than 1000Watt, complete all as specified. Make: Havells/Bajaj/Jaquar Note: Old Geyser taken out from the existing place and shall be deposited at Store Yard of MES and shall be the property of Deptt.”
57Disconnection the electric connection and taking down old unserviceable electric meter from existing location and deposited in AGE E/M store yard.
58S & F Single Phase Electric Meter with LCD display, tamper proof,with accuracy class 1.0 as per IS: 13779, with CTRating capacity 10-40 Amps having anti tempter feature with transperent pilfer proof meter box complet all as specified and directed by Engr-in-Charge.
59M & L for fixing ofpvc insulated FRLScable with multistranded copper conductor 1100 volt grade of size 6 Sqmm for connection from MCB to Elect Meter by using clips in Meter box all as specified and as directed by Engineer-in-Charge.Note : two runs of cable shall be measured as one unit length complet all as specified and directed by Engr-in-Charge.
60Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the GI wire 4 mm dia by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt fillingwith fixing arrangement, funnel wire mesh and earth work in soft soil returning filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI wire of size 4 mm dia with protection pipe of 15mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-40)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
61S&F in replacement of PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 1.50 Sqmm, 3.0-core for connection, complete all as specified and as directed by Engineer-In-charge.
62Disconnecting all electric connections and taking down of air conditioner of any capacity, Split type, installed at the site or mounting at any height and transport to MES store yard/ workshop for servicing, cleaning/ removing the dust internally and externally, replacement of defective spare parts, as required including washing/ cleaning the outer surfaces, evaporator, condensor, air filters, ground chassis including making dry after washing, lubrication to rotatory parts,testing after repairs including making necessary connection to the power point (if required), complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, labour required for repairs/ replacement of spare parts being repair/ replaced, shall be deemed included in quoted rate.
63Description all as serial item No-61.00 here-in-before but for air conditioner of any capacity, window type.
64Supply only following new spare parts required to replacement for repairs of air conditioner (capacity as mentioned) :- (a) Motor for condensor of air conditioner, capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
65(b) Condensing coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
66(c) Thermostat switch for air conditioner, capacity 1.50/ 2.0 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
67(d) Starting relay for air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
68(e) Over load protection relay, air conditioner, capacity 1.50 Ton, window type, complete all as specified and as directed by Engineer-In-Charge.
69(f) Wiring kit for air conditioner, window type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
70(g) Front grill for air conditioner of 1.50 Ton capacity as per existing specifications, complete all as specified and as directed by Engineer-In-Charge.
71(h) Air filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
72(j) Gas/ refrigerant filter for air conditioner mettalic type), capacity 1.50 ton, window type, complete all as specified and as directed by Engineer-In-Charge.
73(k) Cooling coil for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
74(l) Condensor fan blade for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
75(m) Operating knob for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
76(n) Fan for blower motor of air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
77(o) Hermetic sealed unit (compressor) suitable for window type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
78(p) Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 1.50 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
79(q) Hermetic sealed unit (compressor) suitable for split type, uncut, for air conditioner of 2.0 Ton capacity, complete all as specified and as directed by Engineer-In-Charge.
80(r) Printed Circuit Board for air conditioner, split type, capacity 1.50 Ton and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
81(s) Blower motor for air conditioner, capacity 2.0 ton, split type, complete all as specified and as directed by Engineer-In-Charge.
82(t) Copper tubes, size ¼ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
83(u) Copper tubes, size ½ inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
84(v) Copper tubes, size 3/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
85(w) Copper tubes, size 5/8 inches with insulation rubber, suitable for air conditioner of any capacity, split type, and as per existing specifications, fixing in repairs at any levels including clamps and screws, complete all as specified and as directed by Engineer-In-Charge.
86Replacement of old/ damaged base tray with new base tray of mild steel 1.60mm thick, duly painted with powder coated paint, suitable for air conditioner, capacity 1.50 Ton, by removing and re-fixing compressor, condensor coil, copper tube, complete all as specified and as directed by Engineer-In-Charge.
87Recharging/ replacement/ filling of refrigerant (R-134a), suitable for air conditioner of any capacity and any specifications including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed by Engineer-In-Charge.
88Disconnecting all electric connections and transporting water coolers of any type and of any capacity, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the water storage tank, compressor and outer body, tightening the hinges/ screws and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required of water coolers, shall be deemed included in quoted rate.
89Supply only following new spare parts required to replacement for repairs of water coolers (capacity as mentioned) :- (a) Hermetic sealed unit, for water cooler capacity 40/80 liters, complete all as specified and as directed by Engineer-In-Charge.
90(b) Hermetic sealed unit, for water cooler capacity 60/120 liters, complete all as specified and as directed by Engineer-In-Charge.
91(c) Hermetic sealed unit, for water cooler capacity 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
92(d) Condensor fan motor of 1/35 HP for water cooler of any capacity, complete all as specified and as directed by Engineer-In-Charge.
93(e) Automatic thermostat suitable for water cooler any descriptions and of any capacity, complete all as specified and as directed by Engineer-In-Charge.
94(f) Condensor fan blade for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
95(g) Condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
96(h) Strainer (Micro filter) for ¼ gas (refrigerant) for condensor coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
97(j) Evaporator coil for water cooler, capacity 40/80, 60/120 and 150/150 liters, complete all as specified and as directed by Engineer-In-Charge.
98Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 40/80 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
99Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 60/120 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
100Recharging/ replacement/ filling of refrigerant (R-134a), suitable for water cooler any descriptions, capacity 150/150 Litres including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
101S&F in replacement of old unserviceable push button bib tap with new push button bib tap, long shank, cast copper alloy, chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore pipe, fixing in repairs, complete all as specified and as directed by Engineer-In-Charge.
102Spray painting of water cooler capacity 40/80 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
103Spray painting of water cooler capacity 60/120 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
104Spray painting of water cooler capacity 150/150 Litres with two coats of synthetic enamel paint of approved colour by spraying machine including filling cavities with filler, after cleaning all dusts and removing of dent from surfaces including writing of MES Nos. with synthetic enamel paint of black colour on lateral side of water cooler, complete all as specified and as directed by Engineer-In-Charge.
105Disconnecting all electric connections and transporting refrigerator of any capacity and any type, to MES store yard/ workshop for repairing and servicing, by cleaning/ washing the internal surfaces and racks, compressor and outer body and lubrication of movable parts, tightening the hinges and replacement of defective spare parts including testing after repairs and making necessary connection to the power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required in replacement of old defective spare parts/ items shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and spare parts such as lubricating oil/ grease of refrigerator required being repair/ replaced,shall be deemed included in quoted rate.
106Supply only following new spare parts required to replacement for repairs of refrigerator (capacity as mentioned) :- (a) Thermostat with auto defrost button for refrigerator of any descriptions, capacity 165 to 340 litres, complete all as specified and as directed by Engineer-In-Charge.
107(b) Hermetic sealed unit uncut, capacity 1/8 HP, suitable for refrigerator of 165 to 210 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
108(c) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 210 to 285 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
109(d) Hermetic sealed unit uncut, capacity 1/6 HP, suitable for refrigerator of 300 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
110(e) Hermetic sealed unit, capacity 1/6 HP, suitable for deep freezer of 300 to 405 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
111(f) De-frost timer TMDE706 SC cycle time 6H35M, 60 Hz/ 7H54M, 50 Hz, single phase, 220- 240 Volts, suitable for deep freezers, complete all as specified and as directed by Engineer-In-Charge.
112(g) Bimotel component of 4/3 wire for freezer/ refrigerator, capacity 285 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
113(h) Relay, PTC of any type, suitable for refrigerator of 300/310 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
114(j) Refrigerator door seal of rubber gasket including proper insulation, for refrigerator of 165 to 215 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
115(k) Refrigerator door seal of rubber gasket including proper insulation and magnetic system, for refrigerator of 280 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
116(l) Lamp suiatble for refrigerator, pin/ screw type, for refrigerator of any capacity, complete all as specified and as directed by Engineer-In-Charge.
117(m) Evaporator coil for refrigerator, capacity 165 to 180 liters, complete all as specified and as directed by Engineer-In-Charge.
118(n) Evaporator coil for refrigerator, capacity 210 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
119(o) Drain/ Ice tray suitable for refrigerator, capacity 165 to 215 liters, complete all as specified and as directed by Engineer-In-Charge.
120(p) Drain/ Ice tray suitable for refrigerator, capacity 280 to 340 liters, complete all as specified and as directed by Engineer-In-Charge.
121(q) Wiring kit for refrigerator, capacity 280 to 340 liters and as per existing specifications, including internal wiring, complete all as specified and as directed by Engineer-In-Charge.
122Replacement of old unserviceable/ damaged PVC staging/ plastic stand with new PVC staging stool/ plastic stand of different sizes, for refrigerator of 165 to 340 liters capacity, complete all as specified and as directed by Engineer-In-Charge.
123Recharging/ replacement/ filling of refrigerant (R-134a), suitable for refrigerators/ deep freezers, any capacity including testing and repairing against any leakage by welding, soldering, complete all as specified and as directed.
124S&F in replacement of Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 40 Amps, 240 Volts, complete all as specified and as directed.
125Disconnecting all electric connections from mains and transporting voltage stabilizer of any type and 1.0 to 5.0 capacity, to MES store yard/ workshop for repairing/ servicing, by cleaning the outer body and replacement of defective spare parts including testing after repairs and making necessary connection with power points, complete all as specified and as directed by Engineer-In-Charge. Note: (i) New spare parts/ items required to replaced shall be measured and paid separately under respective items. (ii) Cost of transportation from site to workshop for repair and workshop to site after repair, repair/ replacement and minor spare parts required being replaced of voltage stabilizer, shall be deemed included in quoted rate.
126Supply only following new spare parts required to replacement for repairs ofvoltage stabilizer (capacity as mentioned) :- (a) Voltmeter, rating 0-300 Volts, analog type, round shap, 2.50 inches dia, complete all as specified and as directed by Engineer-In-Charge.
127(b) Power relay, 24 Volts, 260 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
128(c) Power relay, 18 Volts, 500 Ohms, 30 Amps (set of three) suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
129(d) Bakelite terminal strip, (bakelite connector), 4-way, suitable for voltage stabilizer capacity 1.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
130(e) Printed Circuit Board with 15 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 1.0 KVA to 2.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
131(f) Printed Circuit Board with 24 Volts IC, with internal wiring, suitable for voltage stabilizer capacity 3.0 KVA to 5.0 KVA, complete all as specified and as directed by Engineer-In-Charge.
132(g) Trigger transformer (control step down transformer), 24 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
133(h) Trigger transformer (control step down transformer), 18 Volts, 260 Ohms, suitable for voltage stabilizer, complete all as specified and as directed by Engineer-In-Charge.
134Rewinding of main transformer of voltage stabilizer capacity 0.50 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
135Rewinding of main transformer of voltage stabilizer capacity 1.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
136Rewinding of main transformer of voltage stabilizer capacity 2.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
137Rewinding of main transformer of voltage stabilizer capacity 4.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
138Rewinding of main transformer of voltage stabilizer capacity 5.0 KVA, single phase, with super enameled copper winding wire of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge Note: Rewinding of transformer shall have same number of turns of winding wire and with matching to manufacturer design.
139Taking down existing desert cooler of any capacity, mounting in any locations and transporting to MES store yard/ workshop for carrying out necessary repairs, servicing, oiling/ lubricating, cleaning the water tank, motor, blades and testing, return the same after carrying out necessary repair work installation at site or other location, including repairs of defective cable connections and making connections of indicating lamps, PVC water pipes and elbow etc, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Spare parts shall be measured and paid separately under respective items of BOQ but cost of transportation to workshop and back to site, repairs shall be deemed included in quoted rate. (ii) Cost of minor spare parts such as PVC elbows, flexible pipes, lubricants, rubber pads and wire mesh shall be deemed included in quoted rate.
140Supply only following new spare parts required to replacement for repairs of desert cooler (capacity as mentioned) :- (a) Fan motor, AC operated, single phase, three wires, capacity 1/7 HP, 240 volts suitable for desert cooler and making necessary electric connection and fixing mild steel arms, complete all as specified and as directed by Engineer-In-Charge.
141(b) Selector switch for controlling of motor speed, 240 volts, 50Hz, three steps, complete all as specified and as directed by Engineer-In-Charge.
142(c) Submersible water pump (tullu pump), AC operated, single phase, capacity 1/20 HP, 240 volts suitable for desert cooler and making necessary connection to power supply including flexible PVC tubing of required size, complete all as specified and as directed by Engineer-In-Charge.
143(d) Wooden wool/ grass pads for three sides including binding with GI wire tightly, for desert cooler of any specifications, complete all as specified and as directed by Engineer-In-Charge.
144(e) Fan blade (Set of three), mild steel, existing size, with fixing screws with motor, suitable for dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
145(f) Mild steel wire mesh, made with 2.0mm dia gi wire powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
146(g) Mild steel side, back grill including louvers fins, powder coated paint, suitable for fixing wood wool pads, for desert cooler of any descriptions, complete all as specified and as directed by Engineer-In-Charge.
147S&F in replacement ofball valves with new ball valve, PVC, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 15mm bore pipe, complete all as specified and as directed by Engineer-In-Charge.
148S&F in replacement of old unserviceable/ damaged PVC connections with new PVC connections 15mm size, length 600mm with PTMT nuts at both ends, for inlet water supply, complete all as specified and directed by Engineer-In-Charge.
149S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 4.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
150S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, capacity 10.0mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
151S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, 36mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
152S&F in replacement of old unserviceable/ damaged capacitor with new capacitor, 45mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
153S&F in replacement ofold unserviceable/ damaged starting capacitor with new starting capacitor, 40/ 60mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
154S&F in replacement of old unserviceable/ damaged starting capacitor with new starting capacitor, 100/ 120mfd, suitable for electric equipments, complete all as specified and as directed by Engineer-In-Charge.
155Preparation of old painted surfaces of desert cooler metallic body by scrapping old paint with emery/ sand paper and spray painting with one coat of red oxide on internal surfaces and one coat of synthetic enamel paint on external surfaces in colour as approved and writing MES No. on body of dessert cooler, complete all as specified and as directed by Engineer-In-Charge.
156S&F in replacement of Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 10.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 6.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications incl taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Two runs of 10.0 sqmm copper wires and one run of 6.0 Sqmm copper wires including PVC conduit shall be measured as one unit.
157S&F in replacement of Sub main wiring for circuits/ submain wiring alongwith earth wire with two run of 4.0 Sqmm of fire resistance, PVC insulated copper conductor, single core cable, multi-stranded, FRLS, ISI marked, 1100 Volts grade and one run of 4.0 Sqmm, FRLS, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, drawn in and including non metallic medium grade rigid PVC conduit, fire resistance, ISI marked, 25mm dia including all accessories, concealed by chasing/ cutting grooves in the surface of walls/ floors/ ceilings and making good the disturbed surface matching to existing descriptions/ specifications incl taking down old sub main, complete all as specified and as directed by Engineer-In-Charge. Note: Three runs of 4.0 Sqmm copper wires including PVC conduit shall be measured as one unit.
158S&F in replacement of old unserviceable/ damaged MCCB with new MCCB, Three pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed. Make: Schneider cat part No- C11E3TM100B or equivalent in L&T/ Legrand/ ABB/ Siemens.
159S&F in replacement of Sheet metal enclosures for Single Pole and Neutral distribution boxes with double door glazed for incorporating MCBs, IP-43, 8-way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and as directed by Engineer-In-Charge.
160S&F in replacement of old unserviceable MCB with new MCB, Single pole and Neutral, 40 Amps, 240 Volts, having breaking capacity of 10 KA, ‘C’ series, conforming to IS/IEC: 60898, complete all as specified and as directed by Engineer-In-charge.
161S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
162S&F in replacement of, 1100 Volts grade, heavy duty, multi-stranded cable, PVC insulated aluminium conductor, multi-stranded, cross sectional area 10.0 Sqmm, 2-core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and as directed by Engineer-In-Charge.
163S&F in replacement of PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 4.0 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
164S&F in replacement of PVC insulated FRLS flexible cable with PVC insulated, sheathed, multi-stranded copper conductor 1100 volts grade, size 2.50 Sqmm, 3-core for connection, complete all as specified and as directed by Engineer-In-charge.
165S&F in replacement of Sheet metal enclosures with socket plug top and MCB suitable for single pole and neutral including a two pin and earth plug and socket complete with one single pole MCB, single pole, 20 Amps, 240 Volts, complete all as specified and as directed by Engineer-In-Charge.
166S&F in replacement ofplug top with new plug top, 15 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
167S&F in replacement of plug top, 5 Amps, 3-pin, 240 volts, complete all as specified and as directed by Engineer-In-Charge.
168S&F in replacement of PVC insulated flat twin core aluminium stranded cable of 4.0 sqmm, complete all as specified and as directed by Engineer-In-Charge.
169S&F in replacement of PVC insulated flat twin core aluminium stranded cable of 6.0 sqmm, complete all as specified and as directed by Engineer-In-Charge.
170S&F in replacement of PVC insulated flat twin core aluminium stranded cable of 10.0 sqmm, complete all as specified and as directed by Engineer-In-Charge.
171S&F in replacement of PVC insulated flat twin core aluminium stranded cable of 16.0 sqmm, complete all as specified and as directed by Engineer-In-Charge.
172SPECIAL NOTE FORAPPLIANCES REPAIRS: The contractor will submit acopy of Memorandum of under standing from OEMs ( or authorized dealers) to the Engr-in-Chargefor the respective E/M equipments before start of repair work. The details of OEMs are as under:- (A)AIR CONDITIONER (i) HITACHI(ii) BLUE STAR (iii) VOLTAS(iv) DAIKEN (B)FREEZER/DEEP FREEZER (i) LG(ii) SAMSUNG (iii) VOLTAS (iv) BLUE STAR (C) EXHAUST FANN & CEILING FAN (i) BAJAJ(ii) CROMPTON (iii) HAVELLS(iv) ORIENT (D) WATER HEATERS/GEYSER (i) BAJAJ(ii) HAVELLS (iii)RACOLD (E) WATER COOLER (i) VOLTAS(ii) BLUE STAR (iii)SHRI RAM (USHA)
173Amount of Schedule of credit of for Rs 227740.50 shall be deducted from quoted amount.