Tender For Spl Rep To Ber Cooling Appliances And Spl Rep Of Amf Panel Of Dg Set At Af Stn Gorakhpur., gorakhpur-Uttar Pradesh

Military Engineer Services-MES has published Tender For Spl Rep To Ber Cooling Appliances And Spl Rep Of Amf Panel Of Dg Set At Af Stn Gorakhpur.. Submission Date for this Tender is 23-03-2024. Diesel Generators Tenders in gorakhpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42479782
Corrigendum : Tender For Spl Rep To Ber Cooling Appliances And Spl Rep Of Amf Panel Of Dg Set At Af Stn Gorakhpur.
Open Tender
Indian
Uttar Pradesh
gorakhpur
23-03-2024

Tender Details

Tender For Spl Rep To Ber Cooling Appliances And Spl Rep Of Amf Panel Of Dg Set At Af Stn Gorakhpur.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 95520.0 /-
Tender Value
INR 47.76 Lakhs /-

BOQ Items

Name of Work: SPL REP TO BER COOLING APPLIANCES AND SPL REP OF AMF PANEL OF DG SET AT AF STN GORAKHPUR
Sl. No. Item Description
1Supply and installation and testing in repairs spilit type Air Conditioner invertor technology of capacity 1.5 TR .High energy efficiency, R-32 refrigerat, conder coil copper, Indoor Noise level-High 45 db, Low 37 db, Evaporator fin type -hydrophilic blue fins, Condenser fin type anti-corrsive blue fins, Dust filter, Auto Restore,Sleep mode,along with remote for working on 230V, 50 Hz. Supply complete including culting of existing wall/ window and proper fixing making good disturbed surface wit existing surface & decorative ply if required. Old split A/C deposited MES store yard . Compomple allow specified and directed.Make: Carrier / Voltas/ Blue Stat / LG
2Supply and installation and testingin repairs of Refrefrigerator , 275 Lt, High energy efficiency, Economical and cooling without fluction, Inverter, Stabilizer free operation ,door lock, Defrost system, Material strinless steel, Shelt type-toughened glass, Fleet driven single phase, 230V , 50 Hz supply complete. Old Refrigerator deposited MES store yard. Complete allow specified and directed. Make: Voltas / LG
3Supply and installation and testingin repairs of Refrefrigerator , 285 Lt, High energy efficiency, Economical and cooling without fluction, Inverter, Stabilizer free operation door lock, Defrost system, Material strinless steel, Shelt type-toughened glass, Fleet driven single phase, 230V , 50 Hz supply complete. Old Refrigerator deposited MES store yard. Complete allow specified and directed. Make: Voltas / LG
4Supply and installation and testing of Refrefrigerator , 175 Lt, High energy efficiency, Economical and cooling without fluction, Inverter, Stabilizer free operation door lock, Defrost system, Material strinless steel, Shelt type-toughened glass, Fleet driven single phase, 230V , 50 Hz supply complete. Old Refrigerator deposited MES store yard. Complete allow specified and directed. Make: Voltas / LG
5Supply and installation and testing of Refrefrigerator , 280 Lt, High energy efficiency, Economical and cooling without fluction, Inverter, Stabilizer free operation door lock, Defrost system, Material strinless steel, Shelt type-toughened glass, Fleet driven single phase, 230V , 50 Hz supply complete. Old Refrigerator deposited MES store yard. Complete allow specified and directed. Make: Voltas / LG
6Supply and installation and testingin repairs of Refrefrigerator , 310 Lt, High energy efficiency, Economical and cooling without fluction, Inverter, Stabilizer free operation door lock, Defrost system, Material strinless steel, Shelt type-toughened glass, Fleet driven single phase, 230V , 50 Hz supply complete. Old Refrigerator deposited MES store yard. Complete allow specified and directed. Make: Voltas / LG
7Supply and installation and testingin repairs of water coolerelectric driven (single phase), 230V, 50 Hz having approx storage capacity of 40 liter and normal cooling capacity of 40/40 Liter per hour, Reciprocating compressor, Refrigerant R-22, Front Top Stainless steel, Front bottom Stainless Steel , Side stainless steel, Rear Stainless steel, Chiller Tank Stainless steel, Legs PP(B120MA) Make: Voltas / Usha / Blue star. (Old water cooler shall be deposited MES store yard)
8Supply and installation and testingin repairs of water coolerelectric driven (single phase), 230V, 50 Hz having approx storage capacity of 60 liter and normal cooling capacity of 60/60 Liter per hour, Reciprocating compressor, Refrigerant R-22, Front Top Stainless steel, Front bottom Stainless Steel , Side stainless steel, Rear Stainless steel, Chiller Tank Stainless steel, Legs PP(B120MA) Make: Voltas / Usha / Blue star(Old water cooler shall be deposited MES store yard)
9Supply and installation and testingin repairs of water coolerelectric driven (single phase), 230V, 50 Hz having approx storage capacity of 120 liter and normal cooling capacity of 120/120 Liter per hour, Reciprocating compressor, Refrigerant R-22, Front Top Stainless steel, Front bottom Stainless Steel , Side stainless steel, Rear Stainless steel, Chiller Tank Stainless steel, Legs PP(B120MA) Make: Voltas / Usha / Blue star. (Old water cooler shall be deposited MES store yard)
10Taking down and refixing of AMF Panel of different capacities ,testing and Complete in all respect includingmaking AMF Panel proper functional Upto 40/ 50/62.5/82.5 KVA DG Set. Note Labour element for taking out unseviceable parts if any shall be deemed included in quoted rates and defective part will be measured and paid seprately under respective itema here-in- under.
11All as per item No 10 above but capacity 100/125/140/160 kvaDG set. Complete all as specified and directed at site.
12Supply and replacement of AMF Panel suitable for upto 50 KVA DG Set with all required component parts like bus bar, CT,contactor,relays,switches,voltmeter,indicating lamps,control wiring etc.Including installation properly at site and making proper connection including test and trial.(alternate ATC) Complete all as specified and directed at site.
13Supply and replacement of AMF Panel suitable for 62.5 KVA DG Set with all required component partslike bus bar, CT,contactor,relays,switches,voltmeter,indicating lamps etc. Including installation properly at site and making proper connection including test and trial.(11 End,29 End,274SU) Complete all as specified and directed at site.
14Supply and replacement of AMF Panel suitable for 200 KVA DG Set with all required component partslike bus bar, CT,contactor,relays,switches,voltmeter,indicating lamps etc. Including installation properly at site and making proper connection including test and trial.(sub stn 2, JTF Hangar, 27 SQN) Complete all as specified and directed at site.
15Supply and fix only rotary selector switch. 4 Pole.Complete all as specified and directed at site.
16Supplyand fix only rotary selector switch 3 pole.Complete all as specified and directed at site.
17Supplyand fix only Auto/Manual Selector Switch.Complete all as specified and directed at site.
18Supply and fix only Volt Meter Led.Complete all as specified and directed at site.
19Supply and fixonly Ampere Meter Led.Complete all as specified and directed at site.
20Supply and fixonly Push Button.Complete all as specified and directed at site.
21Supply and fix only Under Voltage Relay. Complete all as specified and directed at site.
22Supply and fix only single phase preventor. 3 phase. Make Pic,Minilac or equivalent.Complete all as specified and directed at site.
23Supply and fix only indicating light. R.Y.B Complete all as specified and directed at site.
24Supply and fix only Voltage monitoring relay. 3 phase. Complete all as specified and directed at site.
25Supply and fix only Relay 12v, 24v and 220v. 8 pins with bracket. Complete all as specified and directed at site.
26Supply and fix only Relay 14 pins 12v, 24v and 220v.with bracket. Complete all as specified and directed at site.
27Supply and fix only Timer. 0-60 secs. Complete all as specified and directed at site.
28Supply and fix only on delay timer. Complete all as specified and directed at site.
29Supply and fix only Off Delay timer. Complete all as specified and directed at site.
30Supply and fix only Current Transformer. 100/5A Complete all as specified and directed at site.
31Supply and fix only Current Transformer. 160/5A Complete all as specified and directed at site.
32Supply and fix only Current Transformer. 200/5A Complete all as specified and directed at site.
33Supply and fix only Current Transformer. 300/5A, Complete all as specified and directed at site.
34Supply and fix only Battery Charger suitable of AMF Panel. Trickle battery charging system. 12v . Complete all as specified and directed at site.
35Supply and fix only Battery Charger suitable of AMF Panel. Trickle battery charging system. 24v .Complete all as specified and directed at site.
36S&F Contactor 4 pole with 2no & 2nc Auxillary Contacts. Type MCX 32 of rating 160A. Complete all as specified and directed at site.
37S&F Contactor 4 pole with 2no & 2nc Auxillary Contacts. Type MCX 33 of rating 200A Complete all as specified and directed at site.
38S&F Contactor 4 pole with 2no & 2nc Auxillary Contacts. Type MCX 34 of rating 255A. Complete all as specified and directed at site.
39S&F Contactor 4 pole with 2no & 2nc Auxillary Contacts. Type MCX 41 of rating 325 A.Complete all as specified and directed at site.
40S&F Contactor 4 pole with 2no & 2nc Auxillary Contacts. Type MCX 43 of rating 400A. Complete all as specified and directed at site.
41S&F Contactor 4 pole with 2no & 2nc Auxillary Contacts. 90 to 125 AMP.Complete all as specified and directed at site.
42S&F Contactor 4pole TC. Ref no. LC1FDP1504A of rating 250A. Complete all as specified and directed at site.
43S&F Contactor 4pole TC. Ref no. LC1FDP3304 of make 400A. Complete all as specified and directed at site.
44S&F Contactor 3 pole with 2no 2nc auxillary contact. Type- MNX225 of rating 225A to 300A.Complete all as specified and directed at site.
45S&F Operating Coil for Contactor from 225-350 Amp.Complete all as specified and directed at site.
46S&F Operating Coil for Contactor below 200 Amp Complete all as specified and directed at site.
47S&F mild steel stop solenoid for Engines for DG Set upto 200 KVA Complete all as specified and directed at site.
48S&F mild steel start solenoid for Engines for DG Set upto 200 KVA Complete all as specified and directed at site.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy