| 1 | 1.0) Supply & replacement, erection, testing and commissioning of hot dip galvanized octagonal steel pole of 12 Mtr. height and made of 4 mm thick sheet,having bottom 200 mm OAF & top 100 mm OAF, hot dip galvanized M.S base plate of size 320 mm x 320mm x 20 mm thick, single overhang bracket made of 3.60 mm thick hot dip galvanized M.S. pipe with 1.0 Mtr. longtube of suitable dia to accommodate the pole & fittings, on existing RCC foundation with GI bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box having flush cover with 2 nos mounting strips with tapped holes:- (a) 6 mm thick phenolic laminated / bakelite sheet inside the window mounted on the existingmounting strips inside the flush door. (b) 4 nos. 40 Amp terminal block suitable forfollowing conductor / cable, fixedonDIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / bakelite sheet.(i)16 sq mm conductor – 4 nos and short links 5-nos. (ii)Terminal suitable for 6 SWG GI wire / 1.5 sq mm wire.(c)6 AmpSP MCB,10 kA ‘C’ Series-1 nos. including mountings on DIN channel, Earth stud 2 Nos.welded at suitable height i/c washers, springs washers & nuts etc.(d)Suitable arrangement for saddling of incoming / outgoing cables i/c lugs thimbles etc as required.Including dismantling of existing poles etc. complete as required and credit for dismantled material. |
| 2 | 2.0) Supply, erection, testing and commissioning of hot dip galvanized octagonal steel pole of 12 Mtr. height and made of 4 mm thick sheet,having bottom 200 mm OAF & top 100 mm OAF, hot dip galvanized M.S base plate of size 320 mm x 320mm x 20 mm thick, single overhang bracket made of 3.60 mm thick hot dip galvanized M.S. pipe with 1.0 Mtr. longtube of suitable dia to accommodate the pole & fittings, on existing RCC foundation with GI bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box having flush cover with 2 nos mounting strips with tapped holes:- (a) 6 mm thick phenolic laminated / bakelite sheet inside the window mounted on the existingmounting strips inside the flush door.(b) 4 nos. 40 Amp terminal block suitable forfollowing conductor / cable, fixedonDIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / bakelite sheet.(i)16 sq mm conductor – 4 nos and short links 5-nos. (ii)Terminal suitable for 6 SWG GI wire / 1.5 sq mm wire.(c)6 AmpSP MCB,10 kA ‘C’ Series-1 nos. including mountings on DIN channel, Earth stud 2 Nos.welded at suitable height i/c washers, springs washers & nuts etc.(d)Suitable arrangement for saddling of incoming / outgoing cables i/c lugs thimbles etc as required. |
| 3 | Foundation nuts & bolts |
| 4 | 3.0) Providing and laying in position, reinforced cement concrete (1:2:4 concrete mix) foundation of size 750 mm long x 750 mm wide and 1800 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1960 mm long (approx.) - 8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia. 2800 mm long (approx.)-10 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-24 x 750 mm long (150mm top threaded portion & 250 mm top galvanized portion) M.S. foundation bolt (EN 8-grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with templates/Anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. holes to match with PCD of poles base plate with positioning of foundation bolts and providing 75mm (OD) 2 Nos. DWC pipe for cable entry and exit as required. |
| 5 | Lighting Fixture |
| 6 | 4.0) Supply, installation, testing and commissioning of 150 watt LED street light fitting made up of pressure die cast aluminium housing (IP-66 protection and IK07 impact resistance)complete with all accessories including making connection & complete as per technical specification attached.LED street light fixture of not more than 150 watt and lumens output not less than 17700 lm |
| 7 | Wiring from pole control box to light fitting(s) |
| 8 | 5.0) Supplying and drawing following sizes of FRLS PVC insulated copper conductor Single core cable in the existing surface/recessed steel/PVC conduit/ Pole as required.a) 3 x 1.5 Sq.mm |
| 9 | Cables & cable laying |
| 10 | 6.0)Supplying of following sizes of PVC insulated and PVC sheathed/XLPE aluminium conductor armoured power cable of 1.1 KV grade i/c connection & testing etc. as required and as per technical specification enclosed. |
| 11 | 6.1) 2 x 16 Sq.mm |
| 12 | 7.0)Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 13 | 7.1)63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 14 | 8.0)Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/Metal/DWC pipe / pole as required. |
| 15 | 8.1) Up to 35 Sq.mm |
| 16 | 9.0) Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 17 | 9.1) 80 mm dia |
| 18 | 10.0) Supplying, installation, testing and commissioning of floor mounted feeder panel duly compartmentalized (outdoor type) double door cubicle panel board of Suitable size made out of 2mm thick CRCA MS sheet having hinged gasketed cover and screw type knob with double locking arrangement and rain protection cover mounted on MS angle iron base frame made out of 40 mm X 40 mm X 5 mm angle iron with 1 mtr. Long leg grouted with 1:3:6 foundation and should be as per drawing approved by Engineer-In-Charge. Legs should be covered with brick wall, connection, interconnection with painting after applying a coat of primer,i/c connection inter connection of the accessories mounted there on with suitable size of copper wire with thimble/lugs, earthing the body of the feeder paneli/c supplying & fixing of the following items : INCOMERa) 63A 4 pole 25 kA MCCB - 1 Nob) Ammeter with selector switch (0-25 A)- 1 Noc) Voltmeter with selector switch (0-500 V) - 1 No d) Indication Lamp (RYB) with control HRC fuse with fuse fitting- 1 set.BUS BAR 100 A TPN Al. Bus Bar (suitable size) -1 SetOUTGOING a) 16 A TP&N 10 kA MCB - 4 Nos.b) Power contactor - 1 No.c) Astronomical Timer switch – 1 No.d) Auto/Manual toggle switch – 1 No.e)Compartment having space for DISCOM energy meter with 6mm thick Bakelite sheet for mounting energy meter.f) Danger Notice plate – 1 No.g) Lightning inside the feeder pillarNote: Foundation dully plastered and finished shall be made as per site requirement for which nothing extra shall be paid. |
| 19 | 11.0) Supplying fabrication and installation of wire mesh protection cover guard for main feeder pillar made out of 8 SWG wire mesh of suitable size with MS angle iron base frame 40 mm X 40 mm X 5 mm and 0.5 Mtr. long leg spot and MS strip with support size 40 mm X 6 mm as per drawing approved by Engineer-in-Charge i/c providing door of suitable size with S/F of godown lock, locking arrangement, painting and grouting of angle iron frame in CC 1:2:4 etc. complete as required. |
| 20 | Cable end termination |
| 21 | 12.0) Supplying and making end termination with brass compression gland and aluminium lugsfor following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 22 | 12.1) 2 X 16 sq. mm (22mm) |
| 23 | Earthing |
| 24 | 13.0) Earthing with G.I. Earth Pipe 4.5 mtr long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 25 | 14.0) Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for conneciton etc. as required. |
| 26 | 15.0) Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia GI pipe from earth electrode including connection with GI nut bolt , spring washer, excavation, refilling etc. as required. |
| 27 | 16.0) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing alongwith existingsurface /recessedconduit submain wiring /cable as required. |
| 28 | 17.0) Supply, boring and laying of HDPE DWCpipes (ISI) marked of the 90 mm dia size confirming to IS:4984 with pressure rating of 6KG/Sq.cm by trench less technology with no dig. Method by making bore hole in horizontal direction across the road with boring equipment i/c jointing, cleaning, rodding of pipe performing mandrel test providing suitable covers on mouth of pipes, excavation of pits of required size & depth and laying of cables in the pipe. etc. complete as required. |
| 29 | 18.0) Taking out existing CC work/ interlocking paver blocks from footpath , including removal of rubbish etc. Laying old cement cocrete/ interlocking paver blocks of any design/ shape laid in required line, level over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as reqd. with proper finishing. |