}

Tender For Work No. 01 Construction And Development Work Of Shopping Complex Under Transport Nagar Yojana, bulandshahr-Uttar Pradesh

Bulandshahr Development Authority has published Tender For Work No. 01 Construction And Development Work Of Shopping Complex Under Transport Nagar Yojana. Submission Date for this Tender is 02-03-2024. Civil Work Tenders in bulandshahr Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42478629
Corrigendum : Tender For Work No. 01 Construction And Development Work Of Shopping Complex Under Transport Nagar Yojana
Open Tender
Indian
Uttar Pradesh
bulandshahr
02-03-2024

Tender Details

Tender For Work No. 01 Construction And Development Work Of Shopping Complex Under Transport Nagar Yojana

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Feb-2024 TREM CONDIATION Other 02-03-2024
2 29-Feb-2024 DATE Date 02-03-2024

Key Value

Document Fees
INR 5900 /-
EMD
INR 2416000.0 /-
Tender Value
INR 12.07 Crore /-

BOQ Items

Name of Work : VªkaliksVZ uxj ;kstuk ds vUrxZr esa "kkWfiax dkWEiySDl dk fuekZ.k@fodkl dk;ZA
Sl. No. Item Description
1CIVIL WORK
2Excavation in foundation in ordinary soil (Loam, clay or sand) including lift upto 1.50 M. and lead upto 30 M. and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplusearth as directed by the Engineer-in-charge upto a distance of 30 M. from the foundation trenches. (Where machine can not reach/move).As in item 251 above but excavation in soil mixed with Moorum, shingle, kankar requiring the use of special tools and plant such as pickaxes, sabbals etc. [SI.No.-251] SOR-2022
3Add to items (251-253for every additional 30 M. (100 ft.) lead or part of 30 M (100 ft.) or for every additional 1.50 M. (5 ft.) lift or part of 1.50 M. (5 ft.) [SI.No.-254] SOR-2022
4Supplying and stacking of good earth at site including royalty and carriage upto 5 k m lead complete (earth measured in stacks will be reduced by 20% for payment). [SI.No.-253A+231A+261B] SOR-2022
5Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 Kms. from the site of work and including watering, dressing etc. labour and T&P etc. required for the proper complition of the work. saplings of girth upto 30 cms. measured at a height of 1 M. above ground level and removal of rubbish upto a distance of 50 M. out side the periphery of area cleared.[SI.No.-255] SOR-2022
6Cement Concrete with 4 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work.[SI.No.-279] SOR-2022
7Cement concrete with 4cm gauge approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials labour and tools and plants etc required for proper completion for the work. [SI.No.-281] SOR-2022
82 .5 cm thick Damp Proof Course with Cement and approved coarse sand and grit1:1.5:3with and including water proofing as ordered by the Engineer incharge in the proportion as specified by the manufacturer including supply of all materials, labour, Tools & plants etc. required for proper completion of the work and including proper curing & shutterings as necessary.As in item 360 above but 2.5 cm thick and of cement concrete consisting of 1 part cement, 1½ parts approved coarse sand and 3 parts approved 10 mm. graded stone grit and including water proofing material as ordered by the Engineer incharge in the proportion as specified by the manufacturer. [SI.No.-361] SOR-2022
9Providing and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard settingof concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishingand reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the specified minimum cementcontent, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement. [DSR-2023-5.33]
10All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum. [DSR-2023-5.33.1.1]
11All works above plinth level up to floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum. [DSR-2023/5.33.2.1]
12Centering and shuttering including strutting, propping etc. and removal of form for all heights : [DSR-2023-5.9]
13Foundations, footings, bases of columns, etc. for mass concrete. [DSR-2023-5.9.1]
14Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. [DSR-2023-5.9.2]
15Suspended floors, roofs, landings, balconies and access platform. [DSR-2023-5.9.3]
16Lintels, beams, plinth beams, girders, bressumers and cantilevers. [DSR-2023-5.9.5]
17Columns, Pillars, Piers, Abutments, Posts and Struts. [DSR-2023-5.9.6]
18Stairs, (excluding landings) except spiral-staircases.[DSR-2023-5.9.7]
19Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.[DSR-2023-5.9.15]
20Weather shade, Chajjas, corbels etc., including edges.[DSR-2023-5.9.19]
21M.S. (tor steel or plain) in Plain work such as R.C.C. or R.B. work including bending forproper shape as necessary including bending for proper complition of the work and includingsupply of all steel & wastage , bend, hooks, and authorised overlapping shall be measured. (Labour rate only but including cost of binding wire).[DSR-5.22.1/2022]
22First class Brick Work in 1:4 cement & course sand 2.25 F.M. mortar in foundation and plinth including supply of all materials, labour and T&P etc. requried for proper completion of the work.[SI.No.-305A] SOR-2022
23First class one Brick wall Work in 1:4 cement & COURSE sand 2.25 F.M. mortar in Superstructure work above Plinth level including supply of all materials, labour and T&P etc. requried for proper completion of the work. [SI.No.-305A, 309, 310] SOR-2022
24First class half Brick wall Work in 1:4 cement & COURSE sand 2.25 F.M. mortar in Superstructure work above Plinth level including supply of all materials, labour and T&P etc. requried for proper completion of the work. [SI.No.-305A, 309, 310A] SOR-2022
25Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade. [DSR-2023-8.2.2.2]
26Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.[DSR-2023-8.4]
27Supply and fixing 30 mm. thick Commercial flush door shutters conforming of I.S. 2202 Part- 1(1983) including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges, bolts, locks, handles and springs (excluding cost of fittings). [SI.No.-470B] SOR-2022
28Providing and fixing aluminium sliding door bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 300X16 mm. [SI.No.-9.35.1] SOR-2022
29Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 300x10 mm. [SI.No.-9.36.1] SOR-2022
30Providing and fixing aluminium handles lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125 mm. [SI.No.-9.37.1] SOR-2022
31Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. completeTwin rubber stopper.[DSR-2023-9.101.2]
32Mild steel or iron work in purlins and rafters including drilling holes and fixing in position and including supply of all steel and bolts and nuts, wastage, labour and tools and plant etc. required for proper completion of work (No material shall be issued by deptt.). [SI.No.-512] SOR-2022
33Providing and fixing 1mm thick M.S. sheet sliding shutters with frame and diagonal braces of 40x40x6mm (1½"x1½"x¼") angle iron 3.15mm (1/8") gusset plates at the junctions and corners, hooks at top 25mm (1") dia pulleys at bottom, 40x40x6mm (1½"x1½"x¼") angles and T iron guides at top and bottom respectively including locking arrangement with handles etc. Complete and applying one priming coat of approved lead paint (No material shall be issued by deptt.). [SI.No.-519] SOR-2022
34Supplying and fixing rollingSHUTTERS of approved make made 80x125mm (3"x5") coldrolled M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs. [SI.No.-520] SOR-2022
35Providing and fixing ball bearing for rolling shutters. [SI.No.-523] SOR-2022
36Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/clerestory windows & desertory other Frames/Chowkhat comprising of virgin PVCpolymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 65 x 100 mm. [DSR-2023-26.86.5]
37Supply & fixing in position 900mm height SS 304 grade ramp/staicase railing with Top handrail 2 nos. of 38mm dia.& 1.5mm thick Hollow ss pipe bent and Connected at curvilinear Profile and connected to the Vertical of 40x40mm & 1.5mm Hollow main post as per the drawing.3 nos.dia.16mm & 1.5 mm thick midrail horizontal Member connected with the Vertical post and the vertical Should be fixed to the top of Concrete slab with plate make of Technorails. [NSOR-RA-1]
38PROVIDING AND FIXING SS 304 GRADE MODULAR WELD FREE SS TOP MOUNTING GLASS BALUSTRADE RAILING SYSTEM WITH 13.52mm LAMINATED GLASS OF APPROVED MAKE AS PER ATTACHED DRAWING 40X10MM THICK FLAT BALUSTRADE MATTE FINISHED WITH 110X65mm & 8mmTHICK BASE PLATE WITH HILTI/RAWL PLUG FASTENERS RAILING PIPE SHALL BE50mm DIAMETER & 1.5MM THICK. HEIGHT OF BALUSTRADE SHOULD BE 975mm FROM FFLMake – Technoraill / Dorma / D Line.[NSOR-NSOR-2]
39Glass Railing System :- Supply of modular Transline Block system at Balcony area of suitable for laminated glass ( 6mm + 1.52 PVB + 6mm) supported with structural Aluminium U T6-6005/ 6063- T6 channel 120X69mm wide in profile in blocks sizes 150mm in intervals and 250 mm blocks at every glass junctions, with Aluminium cover plates withT6-6063 grade side fixed to RCC with M10X120mm sleeve Fasteners / mechanical anchors and adjusted to be plum and in-line with all fixing points with necessary EPDM (Grade IHRD MCR 70) bidding andPackings ( PA 6 -Nylon) tested and certified as per company norms along with handrail of Dia.43mm aluminium( T6-6063) round handrail suitable for 13.52 mm glass thickness. Total railing height up to 1000 mm from the FFL. Standard finish- Anodised Champagne 20-25 Microns. Must be suitable for Load Criteria 1.5 -2 Kpa of wind load and 1 KN of live load. Make – Technoraill / Dorma / D Line. [NSOR-NSOR-3]
40Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement
41Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent. [DSR-2023-11.56.1]
42Supply and fixing of Kota stone in flooring 25 mm thick and joint filled with 1:2 cement and coarse sandwitha pproved colouring materials to be given an even shade with 20 mm base coat (bedding) of 1:4 cement & coarse sand morter and polished by hand or machine and finally finished with french manson polish or other approved polish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. [SI.NO.-14.23]SOR-2023
43Supply and fixing 20 mm thick Kota stone tiles in riser of steps, skirting, dado & Pillars laid on 12mm (Avg) thick morter in with 1:3 cement and approved coarse sand morter & jointed with gray cement slurry mixed with pigment to match the shade of slab finished with rubbing and polished of approved quality complete, including supply of all materials, labour, tools and plants etc. required for proper completion of the work. [SI.No.-14.24] SOR-2022
44Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., completeSize of Tile 600x600 mm. [SI.No.-14.26B] SOR-2022
45Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm. [DSR-2023-11.41A.3.1]
46Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. completeSize of Tile 600x600 mm. [SI.No.-14.30B] SOR-2022
47Supply and fixing 6 mm. (¼") China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete, including supply of all materials, labour and Tools and Plants. [SI.No.-628] SOR-2022
48Supply and fixing Galvanized corrugated iron roofing in position including supply of all materials, labour, Tools &plants etc. required for proper completion of the work and including wastage.1.00mm thick. [SI.No.-536] SOR-2022
49Providing and fixing mineral fibre false ceiling tiles at all heights ofsize 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all Tsections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge.With 20 mm thick bevelled tegular mineral fibre false ceiling tile (NRC 0.7) Make : Prominance, RK Ceiling, Earcon, Anakon. [DSR-2023-26.27.2]
5012 mm thick plaster with cement and COURSE sand of 2.25 fineness modules in 1:4 over brick work minimum thickness not to be less than 1cm. including supply of all materials, labour, tools & plants etc. required for proper completion of the work. [SI.No.-584] SOR-2022
51Add for extra labour and materials for plaster over rough face of one brick wall. cm thick. [SI.No.-596] SOR-2022
526 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams. [SI.No.-13.19] SOR-2022
53Providing wall putty on new surface with approved quality material of Berger/ J.K./Birla or similarmake 2 coats. [SI.No.-15.26] SOR-2022
54Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm. [DSR-2023-13.45.1]
55Painting or varnishing with valsper or other approved high grade enamel or superior synthetic clean varnish complete two coat over previously painted surface including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should confirm ISI no. 105/106/133-1950. [SI.No.-647+648] SOR-2023
56Distempering (Two coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shalimar, Asian Paint after thoroughly brushing the surface free from mortar dropping and other foreign matters and also sand papered smooth including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. [SI.No.-649, 650] SOR-2023
57Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All aboveoperations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. [SI.No.-11.14] SOR-2022
58Providing and laying 80mm thick faciory made cement concrete interlocking paver block of M -40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. [A.R.]
59A (GREY)
60B (COLOUR)
61Providing and placing in position 100 mm thick factory made machine & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MSsheetduly painted over priming coat reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. [DSR-2023-16.93]
62Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture"s permanent identification mark to be visible even afterfixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. [DSR-2023-19.16]
63INTERNAL ELECTRICAL WORK
64Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit pipe on surface, complete with 14 SWG copper earth continuity wire, GP Box ,piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed. [121(c)]
65Wiring points for two ways light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy PVC conduit pipe on surface, complete with 14 SWG copper earth continuity wire, GP Box , two ways 2 nos. piano type switches & ceiling rose/angle/ batten holder on 3mm. thick phenolic laminated backelite sheet etc., complete in all respect, as directed.[122(c)]
66Same as in item 174(B) but for plug point with 5 Amp flush type switch and 3 pin socket and earth continuity wire of 1.5 sq.mm. FRLSH PVC insulated multi strand copper conductor cable. [178(B)
67Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. [1139]
68S & F of wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS is PVC insulated copper conductor, single core cable in surface/ recessed as required.
69Add for Invertor Wiring in wiring Point for light/ Fan/ Plug with 1.5 mm Cu Wire. [189(A)]
702 x 2.5 sq. mm + 1x1.5 sq. mm earth wire. [DSR-2022-1.17.11]
71Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. [DSR-2022-4.1]
72100 mm width X 50 mm depth X 1.6 mm thickness
73150 mm width X 50 mm depth X 1.6 mm thickness
74Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. [DSR-2022-4.2]
75100 mm width X 50 mm depth X 1.6 mm thickness. [DSR-2022-4.2.1]
76150 mm width X 50 mm depth X 1.6 mm thickness. [DSR-2022-4.2.1]
77Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. [DSR-2022-4.3]
78100 mm width X 50 mm depth X 1.6 mm thickness. [DSR-2022-4.3.1]
79150 mm width X 50 mm depth X 1.6 mm thickness. [DSR-2022-4.3.2]
80Supplying and installing following size of perforated pre-painted M.S. cable trays Tee’s with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. [DSR-4.4]
81100 mm width X 50 mm depth X 1.6 mm thickness. [DSR-2022-4.4.1]
82150 mm width X 50 mm depth X 1.6 mm thickness. [DSR-2022-4.4.2]
83Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. [DSR-2022-4.5]
84100 mm width X 50 mm depth X 1.6 mm thickness. [DSR-2022-4.5.1]
85150 mm width X 50 mm depth X 1.6 mm thickness. [DSR-2022-4.5.2]
86S&F surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. [1024(A)]
87Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. [DSR-2022-2.10.1-]-A
88S&F of 63 Amp. D.P. Isolator [1005(B)]
89Supplying and fixing Single Pole Blanking Plate in the existing MCB DB complete Etc. as required. [DSR-2022-2.11]-B
90As in item no.1304 (B) but in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor as earth continuity wire. [13049(C) ]
91As in item no.1303(B) but in 25mm dia heavy duty (2mm thick) PVC conduit with 2 number 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth wire drawn inside the conduit. [1303(C)]
92Supply, fixing, connecting and testing of elephone/computer/TV modular sockets modular plate anodised MS box and blanking late in surface/recessedincluding connectionetc as required. [DSR-2022]
93RJ-11 telephone socket two line with shutter. [DSR-2022-1.24.6+1.27.1+1.28.1]
94T.V. CO-axial cable socket outlets of one point. [DSR-2022-1.24.7+1.27.1+1.28.1]
95RJ-45 face plate( computer line) with shutter DN-460. [M.R.]
96Providing, fixing connecting and testing of solder less telephone Tag blockoffollowing capacity ties as required in suitable size ofm.s. hinged lockable cover boxduly painted etc. as required of Krone type. (10 pair Tele Tag Blk ) [M.R.]
97Providing, fixing connecting and testing of solder less Television Junction Box offollowing capacity ties as required in suitable size of m.s. hinged lockable cover box duly painted etc. as required of Krone type. (2 pair T.V Junction Box.) [M.R.]
98Supplying drawing, connecting and testing of 0.61mm dia annealed copper conductor PVC insulated PVC sheathed telephone Wire/cables in Existing PVC conduit or a racks as required. (2 pair Telephone cable. (0.61sq mm) [DSR-2022-1.18.2]
99Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. [DSR-2022-1.19]
100Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. [DSR-2022-1.53]
101Supplying and fixing metal box of following sizes (nominal size) on surface or in reces with suitable size of phenolic laminated sheet cover in front including painting etc as required. (75 mm x 75 mm x 60 mm deep) [DSR-2022-1.22.1]
102Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length 2000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12 mm ,outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra), Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. [725(C)/2018]
103Supply and fixing of one number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. [721/2018]
104Supply,installation testing & commissioning of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required ( 4 mm dia GI wire ) [M.R.]
105Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. [1401/2018]
106Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast luminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. [1402/2018]
107Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. [1413(A)
108S/I/T/C of 8 Passenger lift electric traction. With Machine Roomhaving contract speed of 1.5 Meter per second serving different floors in the lift shaft of size 2000 mm (Width) x 2000 mm (Depth) and 1600 mm pit depthas per detailed specifications attached and as undercomplete with all the equipement and accessories. [M.R.] i) Speed = 1.0 Meter per second ii) 3 stops (ground floor to Third Floor) iii) Rise = 9.50 mtr iv) Stops = 3 Stops with all opening on the same side v) Controller - V3F (Variable Voltage Variable Frequency) vi) Automatic Rescue Device (ARD) compete with dry maintenance free batteries as required. vii) Operation - Microprocessor based Simplex control viii) Power: 400/415 Volts, 3 Phase 4 wire 50 Hz AC system. ix) Traction media =Flat coated steel belt x) Car Finish:Rear Mid Panel = Stainless Steel Honeycomb Rear Corner Panels = Stainless Steel Honeycomb Side Mid Panels = Stainless Steel Honeycomb Side Corner Panels = Stainless Steel Honeycomb Front Panels = Stainless Steel Honeycomb xi) False ceiling finish = Stainless steel #4 (Hairline) xii) Ventilation = Cross flow fan xiii) Hand Rails = Stainless steel mirror finish handrails on rear car panels xiv) Flooring =Vinyl tiles xv) Car doors: Stainless steel #4 (Hairline) xvi) Landing doors: Stainless steel #4 (Hairline) xvii) Car entrance door opening arrangement: (Centre Opening Doors) xviii) Handrail on rear wall of car in SS hairline Finish xix) Lift should be with following: Anti-nuisance Car Call Protection,Independent Service (for Duplex only), Overload Device, Nudging, Emergency Firemen’s Service, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking, Door Open/Close Button, Manual Rescue Operation, Belt Inspection Drive, Auto Fan Cut Off, Emergency Exit, Emergency Landing Device. xx) Car positin indicator = Monochrome LCD-Blue Background & White font Dot matrix (LED) Scrolling Display xxi) Hall fixtures Face Plate = Stainless steel #4 (Hairline) xxii) Hall button arrangement = LCD Monochrome type
109EXTERNAL ELECTRICAL WORK
110Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [501/2018]
111Q) 3.5 core 185 Sq.mm
112P) 3.5 core 150 sq. mm
113O) 3.5 core 120 sq. mm For Fire & Plumbing Pump Panel.
114M) 3.5 core 70 sq. mm For External Lighting Panel
115L) 3.5 core 50 sq. mm For Panel
116K) 3.5 core 35 sq. mm ForPanel, STP & ETP Panel.
117J) 4 core 25 sq. mm
118Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. [503/2018]
119Q) 185 sq. mm 3-1/2 core
120P) 150 sq. mm 3-1/2 core
121O) 120 sq. mm 3-1/2 core
122M) 70 sq. mm 3-1/2 core
123L) 50 sq. mm 3-1/2 core
124K) 35 sq. mm 3-1/2 core
125J) 25 sq. mm 3-1/2 core
126Supply and fixing of vertical air termination final rod comprising of 300mm long x 25mm dia. Copper rod with one pointed prong and 100mm dia x 3 mm thick base plate etc. complete in all respect. [712(A)/2018]
127Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required. [DSR-2022/6.3]
128Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. [DSR-2022/6.4]
129Supply and fixing of horizontal air termination (roof conductor) of 25mm x 3mm G.I. strip, G.I. clamps on surface complete in all respects as approved by Engineerin-charge. [710/2018]
130Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run). [DSR-2022/6.8]
131Supply and fixing of testing joint of G.I. strip 32mm x 6mm and 150mm long with G.I. bolts and nut etc. complete in all respect. [719/2018]
132Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. [DSR-2022/6.14]
133Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. [725(B)/2018]
134Supply and burring of Safe Earthing Electrode T-19 Cu Copper Coated, Length 3000mm, outer pipe 48.4mm x 3.2mm, inner pipe 26.9mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable ofreducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrodeterminal to switch board, cost of 25 x 3 Copper Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. [727(B)/2018]
135Supply and fixing of vertical down conductor of 32mm x 6mm copper strip etc. on approved clamps on surface for lightning conductor complete in all respects (For two stroreyed buildings). [714(A)/2018]
136Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required. [5.20/2018]
137Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. [5.15/2018]
138Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required. [5.18/2018]
139Design, fabrication, assembling, wiring, testing, supply, forwarding to site, unloading, shifting to location, inspection, installation, testing and commissioning of DG & Transformer Changeover Panel cum Main LT Panel, Main distribution panels/ sub-distribution panels and capacitor panel, fabricated out of 14 gauge CRCA sheet steel in cubicle formation, compartmentalized, from 3b consutruction, free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and/ or flats wherever necessary. 16 gauge CRCA sheet steel shall be used for final distribution panels. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 No. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZsupply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. A) Incoming Air Circuit Breakerfrom 250 kVA Transformer - 1, 500 amps 4 pole electrically operated manually draw out type Moudule circuit breaker with microprocessor release unit, for short circuit, over current and earth fault protection with adjustable setting as per specification and with following accessories : Digital load manager (conzerve – EM 6400 with RS-485 or equivalent) of accuracy class-I with 2 No. 800/5 amps 15VA CTs., Phase indicating light shall be protected by 2 amps MCB’s- 3 Set, Three Phase Under voltage relay(27) - 1 Set, Three Phase Over voltage relay(59) - 1 Set, Breaker ON/ OFF/ TRIP indicating lights with control MCB’s- 1 Set, 24 V DC Shunt trip coil. - 1 Set, 240 V AC under voltage release. - 1 Set, Auto-manual / test selector / switch - 1 Set, Breaker control switch - 1 Set, Auxiliary contacts required for necessary interlocking of breakers. Three phase Voltage sensor relay shall be protected by 2 amps TP MCB’s, 1 Set, Transient voltage surge supressor with suitable contactor shall be protected by 2 amps TP MCB’s. - 1 Set, Digital voltmeter with inbuilt selector switch- 1 set, C) Bus Bar: 630 A TPN electrolytic Al bus bar with heat shrinkable insulation sleeve D) Outgoings : 250 Amps 4 Pole MCCB - 4 No., 200 Amps 4 Pole MCCB - 2 No., 150 Amps 4 Pole MCCB - 2 No., 100 Amps 4 Pole MCCB - 2 No., 63 Amps 4 Pole MCCB - 3 No., 150 Amps 4 Pole MCCB - 3No. Spare, 100 Amps 4 Pole MCCB - 2 No. Spare E) Bus Coupler : 800amps 4 pole MCCB, with ON/ OFF/ TRIP indicating lamps withmicroprocessor release unit,etc complete as per specs. Notes:- All outgoing feeders shall have suitable range offollowings: (i) All breakers shall be electrically interlockedasper schematic diagram., (ii) All ACB’s/ MCCB’s shall be suitable for 35 KA breaking capacity., (iii) PLC for load management and supervision., (v) Three phase indicating lamps shall be protected by 6 amps SP MCBs., (vi) All outgoing feeders shall be provided with built-in short circuit & earth fault relay module. MAIN LT PANEL. Asdescribed above. [M.R.]
140SHOP MAIN METER ELECTRICAL PANEL.(GR., 1ST. & 2ND. FL.) (A) Incoming : 1 No. 200 Amps TPN MCCB With following accessories: VAF digital electronic meter with inbuilt selector switch and 200/5 Amps suitable VA, CL 1 CTs . -1 Set, Phase indicating light shall be protected by 2 Amps SP MCB"s -3 Set B) Bus Bars : 400 Amps TPN Aluminiumbars with heat coloured shrinkable insulation sleeve - 1 Set (C) Outgoing : 63 Amps FPMCB- 4 No., 40Amps TPMCB - 2 No. (D) Spare : 40Amps 4PMCB- 3 No. Notes:- (i) All MCCB"s shall be of 25 KA (Ics) breaking capacity., (ii) All MCB"s shall be of 10 KA breaking capacity. SHOP MAIN METER ELECTRICAL PANEL. (GR., 1ST. & 2ND. FL.) Described as above.
141WATER SUPPLY PANEL a) Incoming 1 No. 100 Amps TPN MCCB With 100A change Over switch withfollowing accessories: VAF digital electronic meter with inbuilt selector switch and 100/5 Amps suitable VA, CL 1 CTs . -1 Set., Phase indicating light shall be protected by 2 Amps SP MCB"s -3 Set (b) Bus Bars : 250 Amps TPN Aluminiumbars with heat coloured shrinkable insulation sleeve - 1 Set. (c) Outgoing : 32Amps TPMCB- 2 No., 25Amps TPMCB - 6 No., 20Amps TPMCB - 2 No., 20Amps FPMCB - 1 No. (d) Spare 3Amps 4PMCB- 3 No. Notes:- i. All MCCB"s shall be of 25 KA (Ics) breaking capacity., ii All MCB"s shall be of 10 KA breaking capacity. WATER SUPPLY PANEL described as above [M.R.]
142FIRE FIGHTING PANEL. a)Incoming : 1 No. 150 Amps TPN MCCB With 100A change Over switch withfollowing accessories: VAF digital electronic meter with inbuilt selector switch and 150/5 Amps suitable VA, CL 1 CTs . -1 Set. Phase indicating light shall be protected by 2 Amps SP MCB"s -3 Set b)Bus Bars : 250 Amps TPN Aluminiumbars with heat coloured shrinkable insulation sleeve - 1 Set. c)Outgoing : 63 Amps TPMCB- 4 No., 40Amps TPMCB - 4 No., 20Amps TPMCB - 2 No., 20Amps FPMCB - 1 No., (d)Spare : 3Amps 4PMCB- 3 No. Notes : - i.All MCCB"s shall be of 25 KA (Ics) breaking capacity., iiAll MCB"s shall be of 10 KA breaking capacity. FIRE FIGHTING PANEL described as above [M.R.]
143ELECTRICALLIFTPANEL a) Incoming : 1 No. 100Amps TPN MCCB With 100A change Over switch withfollowing accessories: VAF digital electronic meter with inbuilt selector switch and 100/5 Amps suitable VA, CL 1 CTs . -1 Set., Phase indicating light shall be protected by 2 Amps SP MCB"s -3 Set b) Bus Bars : 200 Amps TPN Aluminiumbars with heat coloured shrinkable insulation sleeve - 1 Set. c) Outgoing : 63 Amps TPMCB- 3 No., 40Amps TPMCB - 2 No., 20Amps TPMCB - 2 No., 20Amps FPMCB - 1 No. d) Spare : 3Amps 4PMCB- 3 No. Notes : - i. All MCCB"s shall be of 25 KA (Ics) breaking capacity., iiAll MCB"s shall be of 10 KA breaking capacity. ELECTRICALLIFTPANEL described as above.
144FEEDER PILLAR PANEL FOR EXTERNAL LIGHTING. Supply, installation, testing and commissioning of cubicle type totally enclosed free standing, dust free, damp and vermin proof and water proof outdoor (IP 55) Feeder pillar fabricated out of 2mm thick CRCA sheetduly powder coated and including supply & fixing the following items and interconnections, wiring with suitable size wires/ cables and including all civil works like excavation, PCC, brick work pedestal, plastering, refilling etc. and as per specifications as required. INCOMER : 1 No. 200 Amp four pole Moulded Case Circuit Breaker (Ics value 25 KA) BUSBARS : 300 Amp TPN busbars of high conductivity electrolytic quality aluminium alloy. INSTRUMENTS & ACCESSORIES : 1 No. 96x96 analogue type Voltmeter suitable range for 3 phase, 4 wire operation with LED display and selector switch withcontrolled by3 sets of 2Amp MCB ., 1 No. 96x96 analogue typeAmmeter of suitable range ( 0to 63Amp), for 3 phase 4 wire operation with LED display and selector switch, 3 Nos of LED type phase indicating lamps (RYB) with controlled by 2Amp MCB ., 1 No.6A, 2 pole Auto/OFF/Manual (2 way with OFF) selector switch. 2 Nos. ofpush button actuator OUTGOING : Outgoing 1(6 PM - 6 AM ): TPN DB 6 No. 10 amps SP MCB per phase as outgoing with 3 No. 40 amps DP RCCB of 30 mA leakage current plus 1 No. 40 amps TP Contactor, push button etc controlled through 0-24 hour timer, photo sensor and 1 No. 40 amps 4 pole MCB as incomer). Outgoing 2 ( 6 PM - 11.55 PM) :TPN DB 6 No. 10 amps SP MCB per phase as outgoing with 3 No. 40 amps DP RCCB of 30 mA leakage current plus 1 No. 40 amps TP Contactor, push button etc controlled through 0-24 hour timer, photo sensor and 1 No. 40 amps 4 pole MCB as incomer). Fidder pillar as discribed above [M.R.]
145Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of Automatic control panels with mixed die electric type capacitors, fabricated out of 14 gauge CRCA sheet steel in cubicle compartmentised, 3b modular construction, free standing, floor mounted, dust and vermin proof with reinforcement of suitable size, angle iron, channel, `T’ sections and/ or flats wherever necessary. Cable gland plates shall be provided on top the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 No. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanized hardwares with zinc passivation shall be used in fabrication of panels. 50 KVAR CAPACITOR AUTOMATIC CONTROL PANEL a) Incoming : 150 amps TPN manually operated fully drawout type air circuit breaker as per specification and with following accessories: 96 x 96 mm sq. 0-500 Volt digital voltmeter with selector switch Phase indicating light shall be protected by 2 Amps SP MCB’s -3 Set Power factor compensating relay (including power factor meter) in 10 steps for automatic cut off or add on capacitor units to keep the power factor at 0.98 with variation of loads. All associated auxiliary contactors/ relays/ timer/ auto manual selector switches to be provided-1 Set. b) Bus Bars : 250 amps TPN Aluminium bus bars with coloured heat Shrinkable insulated sleeves.-1 set c) Outgoings - I : 40 amps TPN MCB -1 Set, Outgoing feeders consisting of following accessories., 80 amps or capacitor duty 525 volts 50 Hz contactors - 1 Sets, “ON” /”OFF”push buttons and indicating lamps - 1 Sets, 12.5 kVAr, 525 volts capacitor unit with detune filters as specified - 1 Sets d) Outgoings - II : 63 amps TPN MCB - 1 Sets, Outgoing feeders consisting of following accessories. 80 amps or capacitor duty 525 volts 50Hz contactors - 1 Sets, “ON” /”OFF”push buttons and indicating lamps -1 Sets, 25 kVAr, 525 volts capacitor unit with detune filters as specified. - 1 Sets, e) Note: All MCCB’s shall be of 35 kA breaking capacity., Fast response time of ‘ON’ capacitors 40-60 miliseconds. , Necessary control and firing card with proper wiring and lugs of the required rating to be provided., Heavy duty exhaust fans to be provided for cooling Thyristors, LED indication for number of capacitor banks ‘ON’., LED indication of Power Factor lagging or leading., The APFC system shall be provided with following : Protections : i. a.Over voltage., ii. b.Voltage imbalance., iii. c.Over temperature-system should be in standby mode & automatically restart after above condition restored.",iv. d. Earth leakage., v. e. 7% value reactors with iron core., vi. Capacitor automatic control panelas described above., a.Over voltage., b.Voltage imbalance., "c.Over temperature-system should be in standby mode & automatically restart after above condition restored.", d. Earth leakage., e. 7% value reactors with iron core., Capacitor automatic control panel as described above. [M.R.]
146Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. [1402/2018]
147Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 15 Watt. to 25 Watt. Confirming to IP 66 protection complete in all respect. [1419/2018]
148Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45 Watt. to 50 Watt. Confirming to IP 66 protection complete in all respect. [1421/2018]
149Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. [DSR-2022/14.16]
15063 mm dia (OD-63 mm & ID-51 mm nominal)
15190 mm dia (OD-90 mm & ID-76 mm nominal
152120 mm dia (OD-120 mm & ID-103 mm nominal)
153Supply, installation, testing and commissioningof floor mounted, dust, damp and vermin proof, cubicle, H. T. Metering Panel made out of 2 mm thick CRCA sheet steel complete with electronic trivector meter, CT’s of 10/5 amp, 0.5 class 15 VA Burden, and PT’s of 11 KV / v3 , 110 V / v3 , 50 VA, conforming to relevant IS standard and complete as required.CT’s, PT’s and trivector meter shall be got tested and approved from local electricity supply authority.The GA drawing also shall be got approved from local electricity authorities before fabrication. The unit shall have provision for sealing and Acrylic window shall be provided to facilitate meter reading. [M.R.]
154Supply and erection of 2 pole structure for terminating 11 KV O.H supply from local electricity authority as per specifications double pole structure shall comprise of : (i) MS tubular Swaged pole 11 Mtrs high (410 SP 57 as per IS:2713), in cement concrete foundation 1:3:6 (1 Cement : 3 coarse sand : 6 graded aggregate 40 mm nominal size) including excavation and refilling etc. as required. The rate shall be inclusive of painting with 2 coats of red oxide primer and 2 coats of aluminium paint. The portion of pole under the ground shall be provided with 2 coats of bituminous paint. (ii) Steel sections, channels angles, flats, clamps, GI nuts, bolts and required hardware etc. of different sizes for cross arms, bracings, supports etc for 2 pole mounting arrangement isolators L.A, trifurcating cable box, GOD etc.. etc. including anti climbing barbed wires (conforming to IS:278) having 4 points barbs spaced 75 ± 12 mm apart. All steel structure shall be given 2 coats of red oxide primer and 2 finishing coats of Aluminium paint as required as per dwgs & direction of Engineer-in-charge (iii) Supply, installation, testing and commissioning of 3 sets of 11 KV pin insulators, 11 KV class disc insulators (3 Nos. in series) to be used for stringing the strain type bus bar, bus bar support insulators complete with galvanised insulator fittings, ball & socket type complete with galvanised strain clamps and fixing hard-wares e.g. bolts, nuts, washers etc. complete as required as per dwgs including stringing of busbars using DOG ACSR conductor and extending connection (jumpering) of 11 KV Air break isolators (DOLO fuse units). (iv) Supply, installation, testing and commissioning of single piece non-linear resistor type lightning arrestor suitable for 3 wire, 11 KV O/H line, rated. Voltage of 12 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement G.I. bolts, nuts, washers etc. as required. (to be provided on all phases.) (v) Supply, installation, testing and commissioning of 400 amps 11 KV single pole out door dropout fuse with resin bonded paper tube fuse based with extra hard PB contract, brown glazed porcelene insulator mounted on galvanised malleable base having 3 phase rupturing capacity of 350 MVA at 11 KV vertically mounted on channels of DP structure including making connections to air break switch as required at suitable height on structure and painting etc. As per specification (for 3 phase) with horizontal double break manually operated gang operating device (Air break switch) with pad locking arrangement (operating rod to be supported properly), complete with operating handle and locking arrangement and set of fuses (vi) Supply, installation, testing and commissioning of GI stay set complete with 20 mm dia 1.8 m long stay rod with 450 x 450 x 7.5 mm anchor plate with thimbles stay clamps, 7/4.00 mm dia GI stay wire, turn buckle (20 mm x 600 mm) strain insulator bow lightner in cement concrete 1:3:6 foundation including excavation of refilling etc. 11 KV Double Pole Structure as described above. [M.R.]
155Supply, Receiving, Unloading, Shifting, Installation Testing & Commissioning of outdoor type Transformer ONAN type with copper winding having following continuous 250 KVA rating, 11 /0.415 KV 3 Phase 50 Hz, Vector group Dyn-11, Off load Tap Changer with tapings in steps of ± 2.5%, ± 5%, 7.5% with oil conservator, silica gel breather having connecting terminals on HV side suitable for connecting 3Cx 240 Sqmm HT cable, having cable termination box on secondary voltage side suitable for terminating 4 No 240mm2 XLPE Armoured cable. Transformer shall be confirming to Energy Efficiency Level 2 as per Latest IS 1180( Part 1 & 2), IS:2026, on Brick /CC/RCC platform with all fittings, accessories, filled with filtered transformer oil including testing and commissioning etc.. Including foundation of Transformer, etc. complete as per technical specifications. [M.R.]
156Supply, installation, testing and commissioning of 180 AH capacity 24 volts DC hermetically sealed maintenance free lead acid batteries duly charged including battery charger unit with provisions of Boost Charing, and Float charging. Suitable for 240 V, including DC DB single phase + 10% AC, 50 Hz supply as per specifications. [M.R.]
157Supply and fixing in position the approved “Shock Treatment Charts” written in English and Local Language. These charts shall be framed in teak wood frame and covered with glass.[M.R.]
158Supply and fixing of 2 metres high cage fabricated with 3mm thick expanded metal fixed on 50mm x 50mm x6mm angle iron frame having vertical members spaced at 1 to 1.25 mts and horizontal members spaced at 1 mt. Thevertical members shall be grouted in floor and horizontal members in the wall to a depth of 300mm with endsforked.[M.R.]
159Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. [M.R.]
160Supply and fixing of in-position the fire extinguishers dry chemical powder (ABC) 2 kg capacity. [M.R.]
161Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. [M.R.]
162Supply and fixing in position 1000 mm wide rubber matting of 11 kV grade as per electricity rules.Thickness of rubber mat shall be not less than 12 mm. [M.R.]
163Supply of fire buckets 5 nos. in each set duly filled with fine sand and fixed on an angle iron frame as per requirement of local authorities. Fire buckets shall be painted red from outside and white from inside with additional handle at the bottom. [M.R.]
164Supply and fixing position the approved single line diagram framed in 1000 x 800 mm size glass frame and installed in main switch room. [M.R.]
165Supply of First Aid box of approved make. [M.R.]
166Supply of tool kit with 1 pair 11 kV rubber hand gloves of approved make. [M.R.]
167Supplying of following Size 3 core, / XLPE power cable of 11 kV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Make:- HAVELLS, KEI, POLYCAB, SKYLINE , RR CABLE) [M.R.]
168240 sq. mm
169300 sq. mm
170Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq. mm and upto 400 sq. mm [DSR-2022/8.1, 8.1.2]
171Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 kV grade of following size in the existing masonry open duct as required. Above 120 sq. mm and upto 400 sq. mm. [DSR-2022/8.4, 8.4.2]
172supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.[DSR-2022/10.4]
173240 sq. mm [DSR-2022/10.4.3]
174300 sq. mm[DSR-2022/10.4.4]
175Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. (for road crossing) [DSR-2022/14.14]
176250 mm dia [DSR-14.14.3]
177INTERNALPLUMBING WORK
178Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests [DSR-2022/17.1.1]
179Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid
180Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
181Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid
182PVC PIVE HEAV SIZE 6KG PRESSURE
183160 MM
184110 MM
18563 MM
186P/F 100 MM DIA NAHANI TRAPE
187S/ F C P GRATING
188P/F 110MM PVC TERMINAL GUARD
189P/F C P BRASS LONG BODY BIB COCK DSR NO 18.51.1
190P/F C P BRASS ANGLE VALVE DSR NO 18.53.1
191P/F WATER TANK DSR 18.48
192P/F GUN MATEL GATE VALVE 25 MM DIA DSR NO 18.17.1
193P/F GUN MATEL GATE VALVE 40 MM DIA DSR NO 18.17.3
194MAKING WATER CONNECTION EXISTING PVC WATER LINE INCLUDEING MS CLAMP FERRUAL,NUT BOLT AND WASHERS ETC COMPLETE
195P/F 15 MM DIA BORE BALL VALVE DSR NO 18.18.1
196Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge
19718.8.1 15 mm nominal dia Pipes
19818.8.3 25 mm nominal dia Pipes
19918.9.5 40 mm nominal dia Pipes
200CPVC UNION (MR)
201NON RETURN VALVE
202P/F OF PVC FITTINGS
203110X110 MM PVC TEE
204110X110X110 MM DOORS TEE
205110 MM ELBOW
206100 MM DOORS ELBOW
207Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore
208P/F OF 10 HP Submersable pump includeing starter of approved make complete with board 80 mm dia cloumn pipe flench assembly bends etc required for proper completion of the work as directed by eic
209Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete DSR NO 17.31/2021
210Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.DSR NO 17.33
21117.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
212EXTERNAL PLUMBING WORK
213Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. [DSR-2022/18.9]
21425 mm nominal outer dia Pipes [DSR-2022/18.9.3]
21532 mm nominal outer dia Pipes [DSR-2022/18.9.4]
21650 mm nominal outer dia Pipes [DSR-2022/18.9.6]
217100 mm nominal outer dia Pipes [DSR-2022/18.9.9]
218150 mm nominal outer dia Pipes [DSR-2022/18.9.10]
219Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : [DSR-2022/18.18]
22025 mm nominal outer dia Pipes [DSR-2022/18.18.3]
22132 mm nominal outer dia Pipes [NS]
22250 mm nominal outer dia Pipes [NS]
223100 mm nominal outer dia Pipes [NS]
224150 mm nominal outer dia Pipes [NS]
225Providing and fixing uplasticised PVC connection pipe with brass unions. [M.R.]
22625 mm nominal bore [NS]
22732 mm nominal bore [NS]
22850 mm nominal bore [NS]
229100 mm nominal bore [NS]
230150 mm nominal bore [NS]
231Supply and laying of following size PVC OF 6 Kg pipe ISI marked along with all accessories like socket, bend, couplers etc. conformimg to ,complecte with fitting and cutting , jointing etc. direct in ground (75 cm below level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required. [SOR(32 IV)]
232160 mm dia[14.16.4]
233Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 [DSR-2022/18.33.1]
234Constructing brick machinery circular type manhol 0.91 m inter internal diameter at bottom and 0.56 m di at top in cement motors 1:4 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, making necessary channel in cement concrete 1:2:4, finished with floating court of neat cement. [DSR-2023/19.9.1]
235Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand Content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, ncluding hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. [DSR-2023/23.12]
236Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, ofReputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. (B) 200 mm nominal size dia [DSR-2022/23.11, 23.11.3]
237INTERNAL FIRE FIGHTING WORK
238Supplying, installation, testing and commissioning of electric driven pressurization pump (Jockey) suitable for automatic operation and consisting of following: complete in all respect as required. [DSR-2022/18.4] Horizontal split casinghigh pressure Single/Multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and flow of 10.8 m3/Hr at 70.0 m head conforming to IS: 1520. Suitable HP, SQ cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with class "F" insulation, conforming to IS: 325. M. S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable reinforced cement concrete pump foundation as per manufacturer"s design including foundation bolts, washers as required with anti vibration pad. 450 lpm at 35 m Head {DSR-2022/23.11.3]
239Providing laying, testing and commissioning of class "C" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge. 100mm dia (on terrace lvl.) [DSR-2022/18.7, 18.7.7]
240Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required. 100mm dia [DSR-2022/18.11, 18.11.5]
241Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 100mm dia [DSR-2022/18.14, 18.14.5]
242Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Gunmetal [DSR-2022/18.9, 18.9.1]
243Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m [DSR-2022/18.17, 18.17.1]
244Supplying andfixing 63mm dia, 15 mtr long RRL hose pipe with 63mm dia male and female gun metal couplings duly binded with GI wire, rivets etc. confirming to IS 636 (type-A)as required.Gun Metal [DSR-2022/18.16, 18.16.1]
245Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required. Gun metal [DSR-2022/18.18, 18.18.1]
246Supply & Fixing of Fire Man"s Axe with heavy Insulated rubber tested up to 20 KV and confirming to IS ;926 as required. [NS]
247Providing & fixing100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg) range, 3 / 8" BSP bottom entry on Pump Delivery Line complete with Ball valve. [NS]
248Providing and fixing M.S. fire hose door (Including door frame and all civil work and finishing) of size 900mm High x 600mm Wide x 900 mm Deep approx.Fabricated from 16 gauge M.S sheet.Provision for hole fasteners on both sides with double dore & frame with 2 nos locking arrangement with 2 nos tower bolts and Glazed with 4mm thick Float clear glass (glass panel to be fix in door panel - 700 mm from the bottom of the door and100 mm from the top /sides of door panel) suitably marked on the outside with the letters "FIRE HOSE".all M.S. work to be stove in Enamled Fire Red Colour over appropriate primer (Front side P.O. Red Paint & inside white paint two coat).The width & height to depend upon the actual size of the fire shaft available.Contractor to make shop drawings and get it approved by Enginner -in-charge/Consultant before fabrication.(Cost shall be inclusive of providing break glass box containing key for the door) [NS]
249Providing laying, testing and commissioning of class "C" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge. [DSR-2022/18.22]
250Providing laying, testing and commissioning of class "C" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge. [DSR-2022/18.7]
251100mm dia (vertical Pipe On Fhc.) [DSR-2022/18.7.7]
25280mm dia Drain (vertical Pipe On Fhc.) [DSR-2022/18.7.6]
253Providing and fixing inspection & testing assembly/drain assembly consist of following :- i) 25 mm dia Inspection Test Valve (Ball Valve) & Piping, (ii) Sight Glass, (iii) Union iv) 50 mm diaball valve for drain with piping The arrangment shall be complete as per drawing and as per NBC provisions. The item will include all works from the sprikler header to the drain pipe. [NS]
254Providing and fixing of carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindricalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to ID:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 4.5 Kg. [SOR-1132]
255Providing and fixing of ABC Powder type fire extinguishers consisting of welded M.S. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to ID:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 4.0 Kg. [SOR-1131]
256Providing laying, testing and commissioning of class "C" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge. [DSR-2022/18.7]
25725 mm dia. [DSR-2022/18.7.1]
25832 mm dia. [DSR-2022/18.7.2]
25940 mm dia. [DSR-2022/18.7.3]
26050 mm dia. [DSR-2022/18.7.4]
26165 mm dia. [DSR-2022/18.7.5]
26280 mm dia. [DSR-2022/18.7.6]
263100 mm dia. [DSR-2022/18.7.7]
264Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :Pendent Sprinkler [DSR-2022/18.21, 18.21.1]
265EXTERNAL FIRE FIGHTING WORK
266Supplying, Installation, Testing & Commissioning of Local Fire authrity approved Electric Driven Main fire pump for Sprinkler / Hydrant applications suitable for automatic operation and consisting of following details given asA, B, C, D, E, F and G : - (A) Horizontal Single / Multi stage Centrifugal End suction, back pull type pump complete for delivery of below mentioned discharge , with necessary Butterfly valve on the suction side ( all items to be matching withthe suction side dia of the pump) and pressure gauge ,Butterfly valve and non return valve on the delivery side side ( all items to be matching withthe delivery side dia of the pump) and including bypass arrangement for Testing of pump, (B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal, (C) Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head, (D) Squirrel cage induction motor suitable for 3 phase, 415 V, 50 HZ, Ac supply 2900 / 1450 RPM T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible coupling , coupling guard complete in all respect., (E) Common bed plate fabricated frommild steel channel for installation of pump and Motor, (F) Pump is to be inspected by third party like RITES / PDIL at manufacturer"s premises and inspection report is to be submitted., (G) Suitable cementconcreat foundation duly plastered with anti vibration pads. a) 2280 lpm at 70 m Head [DSR-2022/18.1.5]
267SITC of Local fire authority approved Diesel Engine driven Pump suitable for automatic operationas per discharge defined beolw consisting of the following details given asA, B, C, D, E and F. : - (A) Horizontal Single / Multi stage Centrifugal End suction, back pull type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, Butterfly valve on the suction side( all items to be matching with the suction side dia of the pump) and pressure gauge ,Butterfly valve and non return valve on the delivery side side ( all items to be matchingwith the delivery side dia of the pump) and including bypass arrangement for Testing of pump., (B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal, (C) Pump shall be capable of furnishing not less than 150 % of rated capacity at a head not less than 65 % of the rated head. The shut off head shall not exceed 120 % of rated head, (D) Radiator cooled Diesel Engine developing suitable BHP for the below mentioned dischargeat 1500 / 1800 RPM, flexible coupling and coupling guard with the Pump, common bed plate for mounting of the Engine and Pump,Antivibration damping arrangement by cushy foot, Diesel Engine starting Panel for starting of the engine automatically if the Normal electrical supply fails with a unit of battery bank of 12/24v,180 Ah, Lead Acid Battery with Boost / Trickle charger as required for operation of Diesel engine, Exhaust Pipe of suitable diameter minimum 10 M length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumping set, (E) Pump is to be inspected by third party like RITES / PDIL at manufacturer"s premises and inspection report is to be submitted., (F) Suitable cement concreat foundation duly plastered with anti vibration pads. a) 2280 lpm at 70 m Head [DSR-2022/18.2.5]
268SITC ofLocal fire authority approved Horizontalsingle stage Jockey pump with CI Body, Bronze impellor, SS shaft, mechanical seal coupled with Squirrel cage induction motor for automatic operationsuitable for three phase, 415 V, 50 Hz AC supply with synchronous speed of 2900 RPM ,T.E.F.C type confirming to IP:55 with flexible coupling and coupling guard with the pump ,Common bed platefabricatedfrom mild steel channel , Suitable cement concreat foundation duly plastered with anti vibration pads. 180 lpm at 70 m Head [DSR-2022/18.3.2]
269Providing laying, testing and commissioning of class "C" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge. [DSR-2022/18.7]
270200mm dia. [DSR-2022/18.7.9]
271150mm dia. DSR-2022/18.7.8]
272Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required. [DSR-2022/18.11]
273200mm dia
274150mm dia
275Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. [DSR-2022/18.14]
276200 mm dia
277150 mm dia
278Providing & fixing100mm dia bourden type, Stainless steel dial type pressure Gauge (0 - 16 Kg ) range, 3 / 8 " BSP bottom entry on Pump Delivery Line complete with Ball valve [M.R.]
279Supplying andfixingair vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm. in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm diagun metal wheel valve, with required accessories, pressure gauge a and painting with synthetic enamel paoint of approved shade as required. [DSR-2022/18.20]
280Providing and fixing Pressure switch in the MS pipe Line including connection etc. as required. [DSR-2022/18.22]
281Providing and fixing Gear operated Gate Valve connection etc. as required. [M.R.]
282Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia [DSR-2022/18.15, 18.15.3]
283SITC offloor mounted dust and vermin proof compartmentalisedcubical type main fire pump house panel made out of CRCA sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadeThe panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall beof 2.0 mmthick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors and having accessories ( Group -I ) as below: Incomer : 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A Out going :Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation : 2 Sets Jockey Pump : 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable, HP fully automatic Star/Delta starter with overload, protection, current sensing type single phase preventor, complete with all acceessories and internal wiring, required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 Set Diesel Engine Control : Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.
284Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : [DSR-2022/18.1]
285Providing and fixing hose cabinet of size 750x600x250mm made of 2 mm thick MS sheet with 3 mm thick float glass doors in front painted "FIRE" in red paint i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2NoS. 63Øx15m HOSE , 1 no branch pipe mounted on wall or raised brick platform& duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant, as directed by Engineer-in- charge [M.R.]
286Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for uitable dia MS pipe connection conforming to IS 904 as required. [DSR-18.19]
2872 way-100 mm dia M.S. Pipe. [DSR-2022/18.19.1]
2884 way - 150 mm dia M.S. Pipe. [DSR-2022/18.19.2]
289Providing laying, testing and commissioning of class "C" heavy duty MS pipe confirming to IS 3589/1239 including fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gasket and welding etc. and supports, as required and painting with tow or more coats of synthetic enamel paiing of required shade complet as directed by Engineer-iin-charge. 150 mm dia [DSR-18.7, 18.7.8]
290Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :(Gun metal)
291Supplying, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.( 2 way 4 way fire brigade) 80mm dia [DSR-2022/18.11, 18.11.5]
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail