Tender For Supply Erection And Commissioning Of 1 No 1250 Amp 3 Phase Motor Control Centre L.T. Panel And 1 No Amf Panel For Operating 250 Kva Dg Set At Babra Pump House Jhajjar For Use In W.S. Mech. Division, Jhajjar., jhajjar-Haryana

Irrigation Department has published Tender For Supply Erection And Commissioning Of 1 No 1250 Amp 3 Phase Motor Control Centre L.T. Panel And 1 No Amf Panel For Operating 250 Kva Dg Set At Babra Pump House Jhajjar For Use In W.S. Mech. Division, Jhajjar.. Submission Date for this Tender is 01-03-2024. Diesel Generators Tenders in jhajjar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42477375
Tender For Supply Erection And Commissioning Of 1 No 1250 Amp 3 Phase Motor Control Centre L.T. Panel And 1 No Amf Panel For Operating 250 Kva Dg Set At Babra Pump House Jhajjar For Use In W.S. Mech. Division, Jhajjar.
Open Tender
Indian
Haryana
jhajjar
01-03-2024

Tender Details

Supply Erection & Commissioning Of 1 No 1250 Amp, 3 Phase Motor Control Centre L.T. Panel And 1 No Amf Panel For Operating 250 Kva Dg Set At Babra Pump House ( Jhajjar ) For Use In W.S. Mech. Division, Jhajjar

Key Value

Document Fees
INR 5000 /-
EMD
INR 148000.0 /-
Tender Value
INR 73.92 Lakhs /-

BOQ Items

Name of Work: Supply Erection & Commissioning of 1 No 1250 Amp,3 phase Motor Control Centre L.T. Panel and 1 no AMF Panel for operating 250 KVA DG set at Babra Pump House (Jhajjar) for use in W.S. Mech. Division, Jhajjar
Sl. No. Item Description
1Supply, erection and commissioning of LTDB Panel of 1250 Amp. Capacity (IP-54) with all accessories as one incomer ACB 1250 Amp. with 6 No. outgoing each of having MCCB of 400Amp. along with an-addl. MCCB of 100 Amp. for lighting loads, Indicators, Relay, Molers, Push buttons, bus bars and with 4 No. Fully Automatic ATS Starters (Completed in all respect like relays, indicators timer etc.). of 100 HP Motors each with MCCB of 400 Amp. with contactor rating as 400,300,200,100 Amp. with air cooled starter and 2 No. Fully Automatic ATS Starters (Completed in all respect like relays, indicators timer etc.). of 50 HP Motors each with MCCB of 200 Amp. with contactor rating as 200,150,100,50 Amp. with air cooled starterwith designed capacitor bank of 250 KVAR capacity with 8 step APFCR, digital display instruments & other allied accessories for automatic as well as manual operation of capacitor bank suitable for 4 Nos. 100 HP motors & 2 nos 50 HP Motor. Each Stage should have separate protection through MCCB. One No. Incomer MCCB of 400 Amps to be provided for Capacitor Bank. The LTDB should be as per approved design of HID as per Annexure C. with a stand of MS Channel (1.5 ft. Up from floor) & as per approved technical specification with earthing.
2Supply, erection and commissioning of LT Power cable-LT Power Cables 3.5 Core X 400 mm² Copper Conductor XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured (Galvanized steel strip), Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 with Copper thimble, nut & bolt and other allied material completed in all respect for various sites
3Supply, erection and commissioning of LT Power cable-LT Power Cables 3 Core X 120 mm² Copper Conductor XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured (Galvanized steel strip), Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 with Copper thimble, nut & bolt and other allied material completed in all respect for various sites.
4Supply, erection and commissioning of LT Power cable-LT Power Cables 3 Core X 70 mm² Copper Conductor XLPE Insulated, Cores Laid Up, PVC Inner sheathed, Armoured (Galvanized steel strip), Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 with Copper thimble, nut & bolt and other allied material completed in all respect for various sites.
5Supply Erection & Commissioning of AMF Panel for 250 KVA DG set at Babra Pump House. Specification: Automatic Mains Failure (AMF) Control Panel, Where Applicable, Shall Be Able To Start Up The DG Set And Transfer The Load On To The DG Set On Mains Failure Without Requiring Any Human Intervention. Similarly On Restoration Of Mains Supply,it Shall Be Able To Transfer The Load To Mains Supply And Switch Off The DG Set Automatically.Control Panel Should Have Protection Against Under Voltage,over Voltage, Under Frequency, Over Frequency,Low Battery Voltage, Over Current, Earthfault, Short Circuit,Phase Sequence Change Etc. Equipped With Suitable Voltmeter,Ammeter,Frequency Meter,power Factor Meter, Battery Charger, Indicators, Various Switches And Cutout /MCB/MCCB/Main Contactor suitable for 400 KW load/Circuit Breaker Of All Appropriate Rating And Accuracy Class As Per Trade Practice For BetterUtility. Pretreated And Powder Coated Accoustic Enclosure Of CRCA Sheet thickness of 1.6 mm IP Rating Of Accoustic Control Panel IP-54 along with earthing and complete in all respect if any leftover items.
Disclaimer :