Tender For Construction Of Major Bridge On Chalali Jambudi Kadaviya Mirapuri To Mangalpura Baria Faliya Ch 9240 Ta Kalol Dist Panchmahal, godhra-Gujarat

Gujarat State Rural Road Development Agency has published Tender For Construction Of Major Bridge On Chalali Jambudi Kadaviya Mirapuri To Mangalpura Baria Faliya Ch 9240 Ta Kalol Dist Panchmahal. Submission Date for this Tender is 04-03-2024. Bridge Work Tenders in godhra Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

42476484
Tender For Construction Of Major Bridge On Chalali Jambudi Kadaviya Mirapuri To Mangalpura Baria Faliya Ch 9240 Ta Kalol Dist Panchmahal
Open Tender
Indian
Gujarat
godhra
04-03-2024

Tender Details

Construction Of Major Bridge On Chalali Jambudi Kadaviya Mirapuri To Mangalpura Baria Faliya Ch 9240 Ta Kalol Dist Panchmahal

Key Value

Document Fees
INR 18000 /-
EMD
INR 2020000.0 /-
Tender Value
INR 10.11 Crore /-

BOQ Items

Name of Work: CONSTRUCTION OF MAJOR BRIDGE ON CHALALI JAMBUDI KADAVIYA MIRAPURI TO MANGALPURA BARIA FALIYA CH 9+240 TA KALOL DIST PANCHMAHAL.
Sl. No. Item Description
1Description
2Clearing and Grubbing Road Land(By Mechanical Means) Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.
3Markingoutthecentrelineofthebridge&variousothercomponentstructure& complete lining out and levelling withthe theodolites, levels includingconstructing necessary masonry reference pillars for lines and levels and establishing necessary bench marksetc. complete asdirectedincluding thecost ofallmaterials&labourchargesetc. complete.
4Diversion of water course, providing Earthen bund with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
5Providing flood gauge marks on substructure as per design including painting complete.
6Providing and laying filter media with granular crushed aggregates as per specification to a thicknessofnotlessthan600mmwithsmaller sizetowardsthesoilandbiggersize towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8
7Providingweepholesinbrickmasonry/stonemasonry,plain/reinforcedconcrete abutment,wingwall,returnwallwith100mmdiaACpipeextendingthroughthefull widthofthestructureswithslopeof1(V):20(H)towardsdrawingfacecompleteasper drawing and technical specification Clauses 614, 709, 1204.3.7
8Backfillingbehindabutment,wingwallandreturnwallcompleteasperdrawings& technical specification Clause 1204.3.8 Sandy Material
9Earthworkinexcavationforstructuresasperdrawingandtechnicalspecifications Clause305.1includingsettingout,constructionofshoringandbracing,removalof stumpsandotherdeleteriousmaterialanddisposaluptoaleadof50m,dressingof sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil Depth upto 0 to 3m. below GL
10Earthworkinexcavationforstructuresasperdrawingandtechnicalspecifications Clause305.1includingsettingout,constructionofshoringandbracing,removalof stumpsandotherdeleteriousmaterialanddisposaluptoaleadof50m,dressingof sides and bottom and backfilling in trenches with excavated suitablematerial. Ordinary soil Depth upto 3 to 6m. below GL
11Providingconcreteforplain concreteinopenfoundationscompleteasper drawings and technical specifications Clause 802, 803, 1202 & 1203 II P.C.C grade M 15
12Providing and cast in situ controlled cement concrete of M-35 grade as per relevent code for reinforced cement concrete with 20mm down graded crushed stone aggregates of required size in foundation of pierabutment For Pile Cap etc. & Sub-structure including form workshuttering and supporting arrangement (excluding cost of reinforcement ) and transporting concrete from batching plant by transit mixture, placingit in position, Compacting with needle Vibrator including Curing with all labour, material, machinery, all lead, lift etc complete as per drawing and Technical specification.
13Providingconcreteforreinforcedconcreteinopenfoundationscompleteasper drawings and technical specifications Clause 802, 803, 1202 & 1203 II R.C.C grade M 25
14Supplying, fitting and placingTMT bar reinforcement (Fe 500D) bar reinforcement in foundationcomplete as per drawings and technical specifications Clauses 1000 and 1202 3) The work shall be done as per execution drawing.
15Empty boring through all sorts of strata for providing 1.20 m dia RCC bored piles to required depth including flushing necessary casting pipe with all plants and equipments as required as per detailed specifications for Abutment and Piers (Excluding Concrete & Reinforcement)
16Carrying out load test on any pile as per standard procedure laid down in the IS:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load settlement as directed by Engineer and as per specification, and submission of records. a. Load testing of foundation piles including loading with necessary kentledge of any other suitable method a per details (Initial load Test) 1200mm dia Pile
17Carrying out load test on any pile as per standard procedure laid down in the IS:2911 specification including construction of test cap, dismantling the cap after test and cleaning the site and maintaining complete records of load settlement as directed by Engineer and as per specification, and submission of records. b. Load testing of foundation piles including loading with necessary kentledge of any other suitable method a per details (Routine load Test) 1200mm dia Pile
18Performing Integrity Test (low strain) on vertical pile. The item shall include chipping of weak concrete at the top of pile, leveling, bending of reinforcing bars, preparation of pile head including testing with pile driving analyser or approved equivalent. To be carried out at least 15 days after concreting of piles. A specialist approved Agency shall be employed by the Contractor for the test. The test shall be carried out as per relevant ASTM code.The item is including complete testing with approved apparatus, analysis of results and conclusions including submission of test reports in three hard copies with soft copy in CD. 1200mm dia Pile
19Providing and casting in situ controlled cement concrete M-35 for RCC bored pile from 1.2 m. dia. using Tremie Pipe including necessary flushing, dewatering, formwork, mixing in mechanised batch mix plant,transporting, compacting,and finishing including all leads & lifts complete as per detailed specifications. (Excluding Reinforcement)
20Chipping and dressing of the RCC piles upto cut-off level (Min. 1 D) including cleaning of reinforcement and removal of dismantled materials, etc.for providing pile caps as directed by Engineer and as per specification. for 1200 mm dia. pile.
21Providing and installing 6 mm MS liner for bored-cast-in-situ concrete piles including applying protective coating as per drawing and specification and as directed by Engineer.
22Reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 R.C.C. grade M 25
23Reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 R.C.C. grade M 25
24Supplying, fitting and placing TMT bar reinforcement (Fe 500D) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
25Providingandlayingreinforcedcementconcreteinsuperstructureasperdrawingand technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C M 25
26Providing and laying TAR paper below solid slab
27Providingandlayingreinforcedcementconcreteinsuperstructureasperdrawingand technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C M 40
28Supplying, fitting and placing TMT bar reinforcement (Fe 500D) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
291.Providing and laying a buried expansion joint, covered with 12 mm thick, 200 mm wide galvanised weldable structrual steel plate as per IS:2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8 mm dia, 100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, as per technical specifications Clauses 1207.2.3 2.Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight. 3.Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans, covered with sealant complete as per drawing and technical specificationswelding of 8 mm dia, 100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, as per technical specifications Clauses 1207.2.3
30ReinforcedCementConcreteM30gradeapproachslabincludingreinforcementand formwork complete as per drawing and technical specifications Clauses 800 and 1211
31Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
32P.C.C. M 15 ordinary grade (1:2:4)levelling course below approachslab complete as per drawing and technical specifications Clauses 800 and 1211
33Drainage spouts complete as per drawing and technical specifications Clause 1209
34Providing and fixing marble slab including engraving letters / numbers, painting complete.(ii) Size 60cm x 60cm x 4cm
35Painting on Concrete/Steel Surfaces with Epoxy Painting two coats including prime coat with epoxy paint of approved brand on concrete/steel surfaces after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701
36Providing and fixing in position Mild steel dowel bars in pier caps or abutment caps for anchorage in fixed end as per detailed drawings including cutting, bending and welding complete.
37Providing and fixing in position Mild steel dowel bars in pier caps or abutments caps for anchorage in free end as per detailed drawing including cutting, bending and welding complete.
38Providing and laying Extruted Biaxial Polypropylene Geogrid 30 KN and thickness of layer 0.75m up to 3 m height and height between 3 to 6mExtruted Biaxial Polypropylene Geogrid 30 KN and thickness of layer 0.6m as directed by Engineer In charge and as per detailed specification
39Providing and fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing and technical specifications
40Providing and laying rubble pitching of 22.50 cm. thick with filling the sand in the interstices & C.C. 1:3:6 panelling at 3.0 mt. C/C and 30 cms. x 30 cms. panel wall as per the detailed drawing with necessary excavation and providing water chuts of C.C. 1:3:6 at 24.00 mt. C/C providing pointing on rubble pitching in CM 1 : 3 etc. complete.
41Reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204(A) Height from 0.0 to 5.0 M.(3) RCC return (upto 10 ton) M20
42Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
43Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
44Laying and spreading available soil in the subgrade on a prepared surface, pulverising, mixing the spread soil in place with rotavator with 2 per cent slaked lime having minimum 70 per cent of contents of CaO, grading with motor grader and compacting with thesmoothwheel road roller at OMC to the desired density to form a layer of improved Sub-grade as per Technical Specification Cluase 403.
45Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
46Construction of granular sub-base by providing well gradedmaterial, mixing in a mechanical mix plant at OMC, carriage of mixedmaterial to work site upto lead of 1000 m spreading in uniform layers with motor grader on prepared surface and compacting with smoothwheel roller to achieve thedesired density, complete as per Technical Specification Clause 401
47Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with smoothwheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
48Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
49Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
50Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregate either using penetration garded bitumin emulsion to required line, Grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100kn Static road roller capacity. finished to required level and grades to be followed by seal coat of either Type B Technical Specification Clause 508. By Mechanical Means
51Providing and Laying Seal coat sealing the voids in bituminous surafce laid to the specified level, Grade and cross fall using Type B as per Technical Specification.
52Reinforced cement concrete M15grade 200 m stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
53Providing and erecting direction and place identification retro-\reflectorised sign asper IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thickwith areaexceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos.firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
54Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges.The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level.The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube.All M.S. will be stove enameled on both sides.Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
55Providing& fixing logo Board of Prandhan Mantri Gram Sadak Hojna as per standard design of National Rural road Development Agency diamond size ( 600 x 600 mm) 1.5 mm thick plate & board size (900 x 250 mm) 1.5 mm thick M.S. [late and 2.40 meterdeep length single angle 75 x 75 x6 mm size incl. fitting & painting lettering with luminous colour as per drawing incl .fixing in C.C. 1:3:6 etc. comp.
56Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.
57Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.
58Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810
59Constrcution of Temporary Diversion with 7.50m wide formation width & 5.50m wide paved with necessay safety devise as per IRC SP:55 Having specified road Crust 200mm Thick GSB, 200mm Thick WMM, Primer Coat, Tack Coat & 20mm Thick MSS Surafce necessary pavement marking including both side continous on both edge marking /Center Marking with Thermoplastic paint and road stud at every 18m alternative on both edge with necessary poratble barricaeds with retro-reflective paint in alternative yellow and white stiprs, construction zone sign coveringadvance warning zone , approach trastion zone, work zone, and terminal transition zone, necessary regulatry, warning and infomation sign, required red laterns or warning light with all singnals having retro reflective sheet of high intensive garde and providing necessary 900mm dia 12 row double row NP-3 Pipe and maitaning the same through out construction period till completion of project and including final dismataling and disposal of the same.
60Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table1300.1,no fragment weighing less than 25kg laid dry complete as per drawing and technical specifications Clause 1301
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail