Tender For Additional/Alternator To Cladding Work And Connecting Items At Vsn Chiloda Under Ge (Af) Chiloda., chiloda-Gujarat

Military Engineer Services-MES has published Tender For Additional/Alternator To Cladding Work And Connecting Items At Vsn Chiloda Under Ge (Af) Chiloda.. Submission Date for this Tender is 02-04-2024. Mobile Generator Tenders in chiloda Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

42458386
Corrigendum : Tender For Additional/Alternator To Cladding Work And Connecting Items At Vsn Chiloda Under Ge (Af) Chiloda.
Open Tender
Indian
Gujarat
chiloda
02-04-2024

Tender Details

Tender For Additional / Alternator To Cladding Work And Connecting Items At Vsn Chiloda Under Ge ( Af ) Chiloda.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Mar-2024 BOQ Corrigendum BOQ 13-03-2024
2 13-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-03-2024
3 20-Mar-2024 Date corrigendum Date 23-03-2024
4 23-Mar-2024 Date corrigendum2 Date 02-04-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 86960.0 /-
Tender Value
INR 43.48 Lakhs /-

BOQ Items

Name of Work : ADDN/ALTN TO CLADDING WORK AND CONNECTING ITEMS AT VSN CHILODA UNDER GE (AF) CHILODA
Sl. No. Item Description
1M & L for taking out Dhoulpur stone cladding in vertical surfaces of wall of size n. exc 600mmx600mm for height n exc 15m from ground level using necessary scaffolding and frame work in G+2 building complete all as specified and directed by Engr-In-Charge.
2Material & labour Providing and fixing of ACP Cladding in any shape in metallic colour of approved shades made Out 4mm thick ACP material consisting of 3 mm thick FR grade mineral core sandwich between two aluminium sheets (each 0.5mm thick). The ACP cladding sheet shall be coil Coted,with Kynar 500 based PWDF /Lumiflon based flusoropolymer resin coating of Approved colour and shade on face. The base shall be Aluminium rectangular tubing of size not less 22mmx 45mm with 1mm wall thickness. Horizontal member of frame shall be fixed not more than 750mm center to center and vertical member of base frame shall be fixed not more than 1200mmcenter to center. Horizontal & vertical member of base frame shall be fixed on wall with rowel plug size 10x35 & countersunk steel screw size 10x60. Rowel plug & screw shall be fixed not more than 750 mm center to center. ACP shall be fixed on base frame by providing 1mm thick & 8mm wide pressure tape (both side adhesive). Pressure tape shall be fixed on center of rectangular tube and balance portion of tube covered with white silicone. After fixing the ACP on base frame dummy joints shall be provided as per approved design 5 to 8mm wide Dummy joints shall be provided with masking tape and black silicone. After completion and before handing over entire exposed surface of ACP shall be clean with glass cleaning solution in G+2 building including necessary scaffolding and frame work complete all as specified and as directed.
3M & L for refixing Dhoulpur stone cladding in vertical surfaces of wall of size n. exc 600mmx600mm with Anchor bolt of approved Stainless steel A2 (SS 304) frame anchor of size 10x14mm, counter sunk head of Hitachi Koki India, Fisger or HRD-CR2 10 Hilti India for anchoring stone claddingwith their sheaths comprising of 10mm diameter Polyamide PA6 grade sleeve and 7mm diameter double threaded 6.8 grade Hex head double threaded screw using Min two in each stone slabwith tile adhesive LATICRETE 111 Creat filler powder use with LATICRETE 73 Latex admix ,Mixing ratio 20 Kg bag L 111 : 5.5Ltr L73. Tile Grout LATICRETE 500 Series use with LATICRETE 1776 Tile Grout admix , Mixing ratio 10 Kg bag L 600 Series : 3.75 Ltr of L 1776 Grout admix . Water proofing membrane (for wet area ) LATICRETE 9237 water proofing liquid is applied in two coats for a total wet thikness of 1.0-1.5 mm, Coverage varies based on substrate texture & porosite and application technique,all as specified in G+2 building for height n exc 15m from ground level using necessary scaffolding and frame work all as specified and directed by Engr-In-Charge.
4M & L for cleaning of expansion joint n exc 50mm with proper blowing and water spraying, preparing the surface by chopping and finishing edges with proper treatment in G+2 building complete all as specified and directed by Engr-In-Charge.
5M & L for fixing of backer rod of appropriate size as per expansion joint, and application of solution to increase adhesion for Polysulphide Sealeant on both the sides of Expansion Joint and filling with Polysulphide Sealeant Gun Grade for vertical expansion & horizontal Expansion Joint with sealing tape over the expansion joint to cover the same in G+2 building complete all as specified and directed by Engr-In-Charge.
6M & L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
7M& L for brickwork for wallwith flyash bricks having CM 1:6staight or curved on plane exc 6m mean radius complete all as specified and directed.
8M & L for providing, cement concrete Type B1, 1:2:4 (20mm aggregate stone) in roof kerbs or mud stops, rounded or chamfered on edges with WPC compound complete all as specified and directed. (Note:- WPC to be measured and paid seperatly)
9M & L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
10Demolition Cement concrete (unreinforced) Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
11M & L for Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt for wt n exc 4 kg/sqm complete all as specified and directed.
12M & L for RCC Type B-0 1:2:4 (12.5mm graded) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
13M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work not exc 5cm wide for fair finished surfaces complete all as specified and directed.
14Disconnecting existing 1000 litres tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
15Disconnecting existing 500 litres tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position complete all as specified and directed.
16Taking up on down steel tubing and connection incl cleaning for refining of the 15mm bore of pipe complete all as specified and directed.
17b) All as per item No 16 here in before but 25mm bore of pipe.
18c)All as per item No 16 here in before but 50mm bore of pipe or over.
19Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) of the 15mm bore of pipe complete all as specified and directed.
20b) All as per item No 19 here in before but 25mm bore of pipe.
21c)All as per item No 19 here in before but 50mm bore of pipe or over.
22S&F tubes medium grade galvanised with all fittings and fixed to complete to walls and ceilings or laid in floors to the 15mm bore of pipe complete all as specified and directed.
23b) All as per item No 22 here in before but 25mm bore of pipe.
24c) All as per item No 22 here in before but 50mm bore of pipe.
25S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-Iof capacity 1000 Ltr including dismantling water tanks and removing to store complete all as specified and directed.
26S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-Iof capacity 500 Ltr including dismantling water tanks and removing to store complete all as specified and directed.
27M & L for 50 mm thick Cement concrete type B- 0, 1:2:4 (12.5mm graded aggregate) complete all as specified and directed.
28Taking down cement plaster of any description including racking out joints, hacking for key and disposing of debris out sideMD land complete all as specified and directed.
29M & L for 10 mm thick rendering in CM 1:6 onconcrete surfaces / fair faces of brick masonary wall, finishedeven and smooth without using extra cement complete all as specified and directed.
30M & L for 15 mm thick rendering in CM 1:4 onconcrete surfaces / fair faces of brick masonary wall, finishedeven and smooth without using extra cement using 3% WPC in top 5mm layer complete all as specified and directed. (Note:- WPC to be measured and paid seperatly)
31M & L for sand finished plaster complete all as specified and directed.
32M&L for applying two coats of oil bound distemper over a coat of primer on previously untreated surfaces of wall including preparation complete all as specified and directed.
33Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
34Supply only water proofing compound complete all as specified and directed.
35S & F 15 mm size gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and including taking down old gate valve complete all as specified and directed.
36S & F 25 mm size gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and including taking down old gate valve complete all as specified and directed.
37M & L for Plain, galvanised, mild steel sheeting of thickness 0.63mm, in ridges, hips, valley gutters, drip and straight flashings or covering expansion joint with grade of zinc coating 275 fixed with screws complete all as specified and directed.