Tender For Repair And Maintenance Of Summer Appliances At Dronachal Bhopal, bhopal-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Summer Appliances At Dronachal Bhopal. Submission Date for this Tender is 14-03-2024. Air Conditioner Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42457123
Corrigendum : Tender For Repair And Maintenance Of Summer Appliances At Dronachal Bhopal
Open Tender
Indian
Madhya Pradesh
bhopal
14-03-2024

Tender Details

Tender For Repair And Maintenance Of Summer Appliances At Dronachal Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 24000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR AND MAINTENANCE OF SUMMER APPLIANCES AT DRONACHAL BHOPAL
Sl. No. Item Description
1M&L for servicingpackage type AC plant of 11 TR capacity of make Blue star with greasing of motor bearings, replacement of belts, adjustment of tension of belt, cleaning of all filters, checking of complete wiring, topup of gas (Refrigerant), tightening of nut bolts, oiling and greasing of all movable parts comp[lete all as specified and up the satisfaction of Engr-in-Charge. Note : Cost of belt, Refrigerant gas and lubricant etc required for servicing is deem to be included in unit rate and no extra cost will be paid for this separately
2Replacement of aluminium fan Blade for condensing fan motor of capacity 11TR capacity.
3Replacement of alumium fan blower for cooling fan motor of capacity 11TR capacity.
4Foam type insulating flexible pipe fitted on suction/discharge copper tubes.
5S&F condenser fan motor of ductable type AC of capacity 11 TR as per existing make and model Complete all as directed by Engineer-in-Charge.
6S&F cooling fan motor of ductable split type as per existing make and model of capacity 11 TRComplete all as directed by Engineer-in-Charge.
7S & F in repairs wiring kit of package type AC plant of 11 TR capacitycomplete with lugs, thimble and selector switch, complete all as directed.
8S & F in repairs starting/running capacitor, suitable for ductable type AC of capacity 11 TR. Complete all as directed.
9Disconnecting Dismantllng and removing of U/S condensor unit coil and S/F in replecement of condensor coil unitincluding connection ofcopper tubingfor of ductable type AC 11 TR capacity all as directed. .
10Disconnecting dismantling and removing ofU/S cooling coil from indoor unit complete and supplyingand fixing of new indoorcooling coil unit of ductable type AC of capacity of 11 TR, including connection of copper tubing all as directed.
11S&F in repaired Rotary type Compressorof package type AC plant of 5.5 TR capacity with starting and running capacity and relay includingconnection of copper tubing and topping up of refrigerant gasfor smooth functioning ,complete all as directed.
12Supply and topping up of Refrigerant gas R-407 inair conditioner at different site as required including brazing and removal of leakage in equipment
13Supply and fixingfan belts of AHU of size B-42 (Make: Dunlop,Fanner) as per existing size after removing the defective worn out fan belt.
14Supply and fixingfan belts of AHU of size A-78 (Make: Dunlop,Fanner) as per existing size after removing the defective worn out fan belt.
15M & L for wall mounted Stablizer of capacity 2 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as specified and directed by Engr-in-Charge.
16M & L for wall mounted Stablizer of capacity 5 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as specified and directed by Engr-in-Charge.
17S & F in repairs PCB Senser unit with wire remotre control of ductable AC indoor unit of Capacity 11 TR for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as specified and directed by Engr-in-Charge.
18M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLS PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 2.5 sqmm and 1 x 2.5 sqmm for earth wire including taking down old wiring all as directed.
19M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLS PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 4.0 sqmm and 1 x 4.0 sqmm for earth wire including taking down old wiring all as directed.
20Supply & fixing in repairs single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 20 Amps complete all as specified and directed by Engr-in-Charge.
21M & L for servicing of window type AC of capacity 1.5/2 TR of any make including cleaning of filter on front side by removing dust, cleaning the condenser including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, replacing worn out rubber, bushes/rubber packing, rectification of unusual noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning Complete all as directed by Engineer-in-Charge.
22S&F in repairs aluminium fan blade suitable for condenser of window type AC of any capacity.
23S&F in repairs PVC fan blower of cooling side of window type AC of any capacity.
24S&F in repairs wiring kit of window type AC complete with lugs, thimble and selector switch, complete all as directed.
25S&F for motor for window type AC of 1.5/2 TR capacity,Complete all as directed by Engineer-in-Charge.
26M & L for servicing of split type AC of capacity 1.5/2 TR of any by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, remore replacing worn out rubber, bushes/rubber packing, rectification of unusal noise, checking of refrigerant standing pressure, topping of refrigerant upto the required level, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning complete all as directed by Engineer-in-Charge.Note: Spare parts will paid in relevant item here in after:-
27Supply only of air filter of size 10 micron Split type AC 1.5/2 TR
28Supply only Blade for condensing fan motor Split type AC
29Supply onlyrunning Capacitor 50 Mfd for 2 TR ac
30Supply only running Capacitor 45 Mfd for 1.5 TR ac
31Supply only condenser coil aluminium/copper of ac capacity 1.5 TR
32Supply only condenser coil aluminium/copper of ac capacity 2 TR
33Supply only suction valve brass type 5/8"of ac capacity 1.5 TR
34Supply only suction valve brass type 5/8"of ac capacity 2 TR
35Supply only coil sensor and room sensor for ac capacity of 1.5/2 TR
36Supply only swing motor for air adjust of suitable size Make:OEM
37Supply only relay for overload of suitable size for ac capacity 1.5/2 TR Make:OEM
38S & F in repairs PCB Senser unit with wire remotre control of ductable AC indoor unit of Capacity 1.5 TR for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as specified and directed by Engr-in-Charge.
39S & F in repairs PCB Senser unit with wire remotre control of ductable AC indoor unit of Capacity 2 TR for removing old PCB and refix with new PCB of same make & capacity and model in the same position complete all as specified and directed by Engr-in-Charge.
40M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 1.5 TR,and S&F the same complete all as specified and directed by Engr-in-Charge.
41M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 2 TR,and S&F the same complete all as specified and directed by Engr-in-Charge.
42S&F of blower motor of capacity 1/30 or 1/20 HP split type AC 1.5/2TR. Complete all as directed.
43M & L for removing the unserviceable compressor sealed unit of any make from window/split type AC of capacity 1.5 TR after cutting copper tubing without any damage to existing parts, replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary, filter etc. jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing etc including testing for smooth functioning. Complete all as directed by Engineer-in-Charge.
44All as per item No 43.00 above but for window/split type AC 2 TR capacity complete all as specified and directed by Engr-in-Charge.
45M & L for removing the unserviciable compressor sealed unit of any make from water cooler 40/80 ltr after cutting copper tubing without any damage to existing part ,replacing compressor with reconditioned compressor of same make complete with erection of compressor on base with suitable capillary , filter etc, jointing of copper copper refrigerent pipe line charging gas to required level , complete including cleaning of fins, leakage testing etc including testing for smooth functioning. complete all as directed by engr in charge.
46S&F in repaired Compressor for Deepfreezer capacity 400 ltr with relay and thermostat completeafter desmantalling and disconnecting of U/S compressor and topping up of refrigerant gas upto required level all as directed .
47S&F in repaired Compressor for Deepfreezer capacity 300 ltr with relay and thermostat completeafter dismantling and disconnecting of U/S compressor and topping up of refrigerant gas upto required level all as directed .
48Supply & fix rubber gaskit of standard size for deep freezer with suitable screw and adhesives including removing u/s gaskits all as directed by Engineer-in-Charge.
49S&F in repairs aluminium fan blade for water cooler
50S&F in repairs thermostat suitable for water cooler of any capacity.
51S&F in repairs waste water tray, stainless steel with coupling suitable for water cooler of capacity 40/80 ltrs. Complete all as directed
52S & F PVC drain out flexible pipe of 20mm dia 70 cms length with two mild steel clamps and necessary brass screws etc for water cooler of any size complete all as directed
53S & F in replacement push cock 15mm bore made out of brass chromium plated self closing vertical type complete all as directed
54Supply & fixing in repair copper cooling coil for deep freezer of capacity 310 ltr with suitable fittings after dismantling and disconnecting of U/S cooling coil including testing complete all as specified and directed by Engr-in-Charge.
55Spply & fixing in repair of condensor motor of deep freezer of capacity 400 ltr with suitable fittings after dismantling and disconnecting of U/S cooling coil including testing.
56Supply& fix in repair 3 pin plug top of 15 amp including 3 mtr including PVC sheathed round flexible wire pvc 3 core 2.5sqmm of 3 mtr length for deep freezer.
57M & L for repair for cutting and removing unserviceable freezer unit of refrigerator capacity 165/170/175 ltrs of any make, and supply and fix new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerator gas and testing for smooth functioning. Complete all as directed.
58S & F in repairs of bulb for pin/screw type 230 Volts suitable for refrigerator 175 to 310 ltrs capacity
59Supply and topping up of Refrigerant gas R 134/404 inrefrigerators/Deep freezers at different site as required including brazing and removal of leakage in equipment
60Supply & fixing in repair copper cooling coil for refrigerator of capacity 190 ltr
61Supply& fix in repair 3 pin tlug top of 5 amp including 3 mtr including PVC sheathed round flexible wire pvc 3 core 40/0.0076 of 3 mtr length for refrigerator.
62M&L for cleaning after takingdown complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamelspray paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No. etc. Complete all as directed by Engr-in-Charge.
63S&F in repairs PVC flexible pipe 16mm outer dia complete with PVC elbow etc.
64S&F in repairs selector switches three way 230 Volts single phase of standard quality fixed in desert coolers.
65S&F in repairs wood wool pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as directed .
66S&F in repairs switch piano type 250 Volts, single pole one ways 5 amps, fixed in desert coolers.
67S&F repairs PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including necessary connection fixed in desert coolers.
68S&F in repairs capacitor 4 Mfd for fan motors of desert coolers.
69S& F in repairs Submersible pump 230 volts suitable for desert cooler of capacity 4000/5000 including necessary wiring complete all as directed. Make Crompton/ Khaitan
70S & F in repairs side shutter (set of three) made out from 24 guagethick galvanized iron sheet suitable for 4000/5000 cum/hrs capacity desert coolers complete all as directed.
71S&F in repairs float valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 142 gm/each. Complete all as directed.
72S & F in repairs Aluminium fan blade for fan motor of desert cooler 20 inch sweep.
73S & F in repairs PVC, 3 way distributor suitable for 15 mm pipe with nut/screws all as directed.
74S & F desert cooler fan motor 3 speed copper winding ISI mark including suitable leg set of three including nut bolt washer all as directed.