Tender For Additional/Alternator To Water Staging/ Overhead Water Tanks And Misc B/R Works To Certain Bldgs At Af Stn Patiala Under Ge (Af) Ambala, ambala-Haryana

Military Engineer Services-MES has published Tender For Additional/Alternator To Water Staging/ Overhead Water Tanks And Misc B/R Works To Certain Bldgs At Af Stn Patiala Under Ge (Af) Ambala. Submission Date for this Tender is 21-03-2024. Over Head Tank Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

42456661
Corrigendum : Tender For Additional/Alternator To Water Staging/ Overhead Water Tanks And Misc B/R Works To Certain Bldgs At Af Stn Patiala Under Ge (Af) Ambala
Open Tender
Indian
Haryana
ambala
21-03-2024

Tender Details

Tender For additional/alternator To Water Staging/ Overhead Water Tanks And Misc B/R Works To Certain Bldgs At Af Stn Patiala Under Ge (Af) Ambala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Mar-2024 CORRIGENDUM NO 01 DATED 05 Mar 2024 Other 14-03-2024
2 14-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 85800.0 /-
Tender Value
INR 42.90 Lakhs /-

BOQ Items

Name of Work: ADDN/ALTN TO WATER STAGING/ OVERHEAD WATER TANKS AND MISC B/R WORKS TO CERTAIN BLDGS AT AF STN PATIALA UNDER GE (AF) AMBALA
Sl. No. Item Description
1Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
2Taking down cement or cement lime plaster, any description on stone walls etc including raking out joints hacking for key, scrubbing down with water, etc, complete all as specified and directed.
3M&L for Vitrified coloured ceramic tiles 10 to 12 mm thick (square/rectangular), area of each tiles exceeding 0.18 sqm but not exceeding 0.38sqm, in floors etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
4M&L for Vitrified coloured ceramic tiles 10 to 12 mm thick (square/rectangular), area of each tiles exceeding 0.18 sqm but not exceeding 0.38sqm, as in skirting etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
5M&L for Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tiles exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
6M&L for coloured glazed ceramic tiles of size350x250x7mm/450 x 350 x 7mm thick on vertical surface such as skirting/dado, set and jointed in neat cement slurry and pointed in colour cement to match over 10 mm thick backing coat in CM 1:4 complete all as specified and directed.
7M&L 18- 20mm thick pre-polished green marble(Udaipur green) (of any type) (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
8M&L for rounding to edges of stone slabs two edge full round,such as in steps,cooking platform and other similar situation complete all as specified and directed.
9M&L for 75mm thick cement concrete 1:3:6 type C1, (using 20mm graded mechanically crushed stone aggregate) as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement,complete all as specified and as directed.
10M & L for providing 3mm thick glass dividing strips and 28mm deep, inserted in position, conform to design, complete all as specified and directed.
11M&L for rendering 15mm thick cement plaster 1:6 on brick masonry surface or surface other than fair face of brickwork surface finished even and smooth without using extra cement, complete all as specified and directed.
12M&L for rendering cement plaster 15mm thick and surface of brick workin two layer i.e (10+5)10mm thick 1st layer and 2nd layer is 5mm cement mortar (1:4) on fair faces ofbrick work or concrete surfaces using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, finished even and smooth without using extra cementcomplete all as specified and directed. Note:- Supply only water proofing compound shall be measured and paid separately.
13M&L for rough cast plaster including 15mm thick rendering in CM 1:3 on brick wall or concrete concrete surfaces complete all as specified in SSR Part - I clause 14.22 complete all as specified and directed. Note : Rough cast finish to be as below :- After applying the under coat of cement mortar 1:3 and while it is still in plasic state the rough cast mixture consisting of crushed stone or fine gravel agg (which is generally of size between 6 to 12mm depending on the texture required ) mixed with course sand and cement in the ratio of 1 : 1 : 1 shallbe applied and finished even. The mixof cement and sand shall be made slightly wetter than normal for rendering to ensure that larger agg are thoroughly covered.
14M&L for preparing of new plastered or un-plastered surfaces and applying two coats of oil bound distemper includingpriming plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified and directed.
15M&L for complete removal of existing treatment and preparation of old plastered or un-plastered surfaces and applying two coats of oil bound distemper including 3mm thick JK birla wall care putty , complete all as specified and directed.
16M&L for preparation for new plastered / concrete wall surfaces, etc. and for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over (camouflage pattern) and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfacesincl providing over a coat of wall care putty over plastered surface to prepare the surface even and smooth, complete all as specified and as directed
17M&L complete removal of existing treatment of wall andpreparationof old plastered or Un plasteredsurfaces of wall and for applying twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over (camouflage pattern) and including providing over a coat of wall care putty over plastered surface to prepare the surface even and smooth, complete all as specified and as directed
18Material and labour anodised aluminium doorand chowkhatsmade out of hollow extruded aluminium section as mentioned below. Each door shall beprovided with 02 Nos disc or Dtype aluminium handles, 02 Nos aluminium tower bolts 200mm long, one brass mortice lock of six levers with key in duplicate and shallbe regulated by provided double action hydraulic floor doorspring/hydraulic door closer (Make sandhu/RITZ).Shutter to be partly glazed with andincluding 5mm thick tinted glass and partlypanelled with and including 12mm thick prelaminated particle board with decorativelaminations on both sides, rubber beading/gasket, anodised aluminium beading, screws complete in all respect complete all as directed by the Engineer-in-charge. Chowkhat/frame: 101.6x44.45x1.5mm thickShutter top and bottom rail: 114.3x44.45x1.5mm thickShutter middle rail : 83.5x44.45x1.5mm thickShutter vertical/style : 83.5x44.45x1.5mm thick MAKE : (i) Anodised aluminium section : JINDAL, HINDALCO, INDALCO (ii)PARTICLE BOARD : NOVAPAN, KITPLY, BHUTAN BOARD (iii)Glass : Saint Gobain, modi guard, TATA.
19Supply and fixing anodisedaluminium window / ventilator including aluminium grill made outof hollow extruded section as mentioned belowand glazed with tinted glass 5mm thick fixedwith glazing clips rubber beading/gasket anodised aluminiumbeading screw and lock type handlesof size 75mm, 2 Nos aluminium tower bolts 150mm long etccomplete all as specified anddirected with the following sizes:- Chowkat/Frame Size :101.6x44.45x1.5mm thick Mullion: Not less than 0.55Kg/RM Shutter : Not less than 0.55 Kg/RM
20Taking down chowkats or frame (doors/windows) of any description n exc 1.5 Sqm each(without taking off shutters from the frames) complete all as specified and directed.
21Taking down chowkats or frame (doors /windows) of any description exceeding 1.5 Sqm each and n.exc 4 Sqm (without taking off shutters from the frames) complete all as specified and directed.
22S&FMS angle iron framed work as in doors or gates of angle or other section conforming to Fe 290(Gde E-165) with gusset plates, rails, braces, etc complete including hanging also fastening and fixing and making the surface good, complete as specified and directed.
23M&L for Preparation of old painted wood and wood base surfaces of any description, not otherwise described over 10 cm width or girth and painting with a coat of sythetic enamel paint, complete all as specified and directed.
24S&F, SS 25mm dia , powder coated, fancy type, aluminium decorative tubular curtain rod with decorative ball type side brackets, stops ,rollers etc, complete all as specified and directed.
25Supply and fixing300mm long, Aluminium alloy,anodised sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sectionsor cast aluminium alloy, complete all as specified and directed.
26Supply and fixing Solid PVC Door frame of size 50 mm x 47mm made out of 5mm plain PVC sheet reinforced with 19mm x 19mm M.S. Square tube profiles are mitred cut at corners and joined by inserting 2 Nos 150 mm long brackets of 15mm x 15 mm MS square tube shall 19 mm x 19 mm in square tubes and suitably screwed suppling & fixing in opening, complete all as specified and as directed by Engineer-in-Charge.
27Supply and fixingfactory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MSframe shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded /sealed to the stiles and rails with suitablePVC sheet beading and joined together with solvent cementand fixed in the frame at site complete as per specification and drawing complete all as specified and directed by Engineer-in-Charge.
28Supply and fixingButt hinges 125 mm size, medium weight, cold rolled mild steel complete all as specified and directed..
29Supply and fixing150mm long Aluminium, anodised, barrel tower bolt of extruded section complete all as specified and directed.
30Supply and fixing aluminium handles, cast type, anodised150 mm size complete all as specified and directed.
31S&F, in repairs, 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice laminations and other side balancing white lamination, fixed with screws to timber frame work in cup boards, rebated or flat edged complete all as specified and directed.
32M&L for 6mm thick external teak wood lipping fixed to18/19mm thick block or Veneered particle boards with nails complete all as specified and directed.
33S&F continuous (piano) hinges, mild steel bright finish or electrogalvanised, width of flap 40 mm complete all as specified and directed.
34S&F hasp & staples 125mm in size, safety type aluminiumanodised fixed with screws, complete all as specified and directed.
35S&F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified and directed.
36Supply and fixing in repairs, PVC valveless, syphonic action type, flushing cistern (ISI marked) of 10 litres capacity, low level (white) with inlet, ball valve, float and handle including bracket and flush pipe complete all as specified and directed.
37Supply and fixing in repairs, vitreous China squatting pan, "Orissa"pattern, size 580 x 440 mm white with integral foot rest and "P" or "S" trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc including all accessories reqd complete all as complete all as specified and directed.
38S & F whiteglazed earthen ware vitreous china wash hand basin of size 550x400mm with and including CI brackets, 32mm bore brass CP waste coupling Inlet/ outlet, 32mm PVC waste pipe and PVC connection/ flexible pipe 600mm size for 15 mm bore pipe with brass nut and washers etc complete all as specified and directed.
39S&F, one piece vitreous china wash down water closet pan (Pedestal pattern), white with "p" or "s" trap (including flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc. including its plastic seat cover white closed pattern with flat bottom and mild steel chromium plated or aluminium hinging device and SS brass chromium plated jet spray fixed with seat cover, complete all as specified and directed.
40Supply and fixing in repairs Vitreous China Urinal, Half stall type, white(back or corner wall type), (excluding flushing cistern, flush pipe and waste pipe), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, complete all as specified and directed
41Supply and fixing in repairs Vitreous china urinal partition white of size 310x700 mm, terminating about 40cm above floor line,complete all as specified and directed.
42S&F, in repairs, 15mm brass chromium plated fancy type bib cock with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
43S&F, in repairs, 15mm stop valves /Angle valves/concealed stop cock, fancy type brass chromium plated for iron pipe or for unions and fixed to 15mm bore pipe, complete all as specified and directed.
44S & F 15mm pillar taps, brass chromium plated fancy typewith capstan heads, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed foriron pipe or for union and fixed to 15mm bore pipe, complete all as specified and directed.
45S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm , complete all as specified and directed.
46S&F in repair 600X450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
47S&F Towel ring 200 mm dia chromium plated fancy type conforming to the sample kept in the office of Engineer-in-Charge.
48Supply and fixing in repairs 32 mm bore dia wastepipe for WHBs/urinals/sinks, including all joints and necessary fitting , complete all as specified and directed.
49S&F Chromium over head shower rose 100mm dia round shape single flow (ABS Body chrome plated with Gray face plate) with rubit cleaning system, with or without swivel joints, any size, including fixing to steel pipe or union, complete all as specified and directed
50S&F Mixer pillar tap, cast copper alloy with capstan head, chromium plated, fancy type, screwed down, high pressure, for hot and cold water, 15 mm bore, complete all as specified and directed.
51S&F brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges for wash hand basin area with brackets complete all as specified and directed.
52Supply and fixing in repairs8mm dia Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in positioncomplete in all respect complete all as specified and directed.
53S&F Toilet paper holder of brass chromium plated conforming to the samples kept in the office of Engineer-in-Charge.
54Supply and fixing in repairs corner Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long , complete all as specified and directed.
55S&F SS grating doom 100/125mm (with or without hole) including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)., complete all as specified and directed.
56S&F gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, 20mm bore, complete all as specified and directed.
57S&F in repair brass chromium plated soap dish complete all as specified and directed.
58Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed.
59Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed.
60S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floorsfor 15mm bore of pipe complete all as specified and directed.
61S&F steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floorsfor 20mm bore of pipe complete all as specified and directed.
62S&F rotational moulded polyethylene water storage tanks of capacity 1000ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR-Part-Iincluding disconnecting and removal of old U/S PVC tank, complete all as specified and directed.
63S&F in repairs 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms) complete all as specified and directed.
64Dismantling of PVC pipes jointed in neat cement mortor and taking out of trenches if required, complete all as specified and directed.
65Supply and fixing in repairs PVC bend any radius, conforming to IS:14735, suitable for uPVC soil waste discharge pipes 110 mm size, with oval and access door,complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
66Supply and fixing in repairs PVC bend any radius, conforming to IS:14735, suitable for uPVC soil waste discharge pipes 75 mm size, complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
67Supply and fixing in repairs PVC cowl any radius, conforming to IS:14735 suitable for110 mm bore, complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
68Supply and fixing in repairs UPVC floor/ Nahani trap with PVC grating suitable for 75 mm external dia,type-B pipes, ISI markedincluding jointing to waste pipe fixed in cement concrete type B1 (1:2:4), complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
69Supply and fixing in repairs PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement for 110 mm external dia,type-B pipes, ISI marked complete all as specified and directed. MAKE: SUPREME, FINOLEX, PRINCE, DIPLAST.
70S&F PVC(SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls complete including fixing clamps, complete all as specified and directed.
71S&F 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors/walls, complete all as specified and directed.
72S&F 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors/walls, complete all as specified and directed.
73Demolition cement concrete (unreinforced) in ground floor and pavings not exceeding 15cm thickness (below or above ground level) complete as specified and directed.
74M&L brickwork with sub class"B" Bricks (old size), straight or curved on plan exceeding 6m mean radius, built in CM 1:4, complete all as specified and directed.
75Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etccomplete all as specified and directed by Engineer - in - Charge.
76Dismantling asbestos cement /Galvalume auminium (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as specified and directed.
77M&L pre painted galvalume aluminium zinc coating GI based corrugated Steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering/cladding to wall fixed with selftapping screwes complete all as specified and directed.
78S & F for pre-painted galvalume aluminum zinc coating GI basedplainsteel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa and grade AZ 150 as in ridge to roof, fixed with self tapping screws complete all as specified and directed.
79M&L for MS work as in tubular/angle roof trusses (framed), trusses, purlins crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces cleats etc conforming to Fe 410 W (Gde E 250) quality B complete all as specified and directed.
80S & F mild steel flat iron wind ties for roof including securing bolts, including necessary driling and similar works conformig to Fe-290 Gde E-165 complete all as specified and directed.
81Material and labour for preparing surfaces of new or previously untreated surfaces ofsteel or metal works and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer over 10cm in width or girth complete all as specified and directed.
82Material and labour for preparing old surfaces of steel or metal works and applying two coats of synthetic enamel paintover 10cm in width or girth complete all as specified and directed.
83Dismantling of wall and ceiling boards (fibre,pulp, insulation, etc or insulation boards/slabs/blankets,any thickness including cover fillets, complete all as specified and directed.
84M&L for 12mm thick Perforated particle board /tiles for insulation and accoustic purpose, 60x60 cm in size, fixed with nails to timber frame work with staples on snap grid, complete all as specified and directed.
85S& F Anodised aluminium snap grid of Size of grid 605 x 605mmfor work for false ceiling, complete all as specified and directed.
86S&F Hanger of GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long expansion hold fastener 12.5mm dia. 40 mm long complete all as specified. made out of GI flat 40x3mm size 60 mm long complete all as specified and directed.
87S&F solid PVC wall lining consisting of 5mm thick plain colour PVC Sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawings, complete all as specified and directed.
88S&F 5 mm thick PVC Sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing and complete all as specified and directed.
89M & L for plain cementconcrete M-10 Nominal Mix (1:2:4) Type B-0 (using 12.50 mm graded mechanically crushed stone aggregate), as in lintels upto 1.5 m clear span, cills, steps,seismic and other similar bands, plinth course, string courses, lacinng courses, parapets and railings, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
90M & L for cutting into existing man holes for connecting new drain pipe of 150mm bore SGSW pipe incl making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete all as specified and directed.
91Supply and laying salt glazed stone ware drain pipe 150mm internal dia conforming to IS laid in trenches and joinged in CM (1:2) complete all as specified and directed
92Material and labour for concrete bed to drain pipes in PCC 1:3:6 type C-2 (using 40mm graded mechanically crushed stone aggregates) including packing under and haunching against the sided of pipe after they are laid in slope and tested for 150mm bore sewer line complete all as specified and directed
93Demolition of mud phuska in roof any thickness and lowering down and removing complete all as specified and directed.
94Dismantling roofbrick tiles or terracing tilesingle layer complete all as specified and directed.
95M & L for Rendering15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fairon in cement mortar (1:3), using water proofing compound as per recommended ratio, after brushing cement slurry complete all as specified and directed. Note:- water proofing compound shall be measured and paid seperately
96M&L for PCC type B-1 (1:2:4), (using 20 mm graded mechanically crushed stone aggregates) asin roof kerbs or mud stops, rounded or chamfered on edges surface channels and drains,Filling of MS sheet chowkats ,roof padding complete all as specified and directed.
97M&L for Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm & adjoining vertical surfaces over clean RCC/plastered roof surfaces complete all as specified and directed.
98M&L for 40 mm thick brick tiles laid on cement mortar (1:6), 15 mm thick and joints filled with flush pointing in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and directed.
99Supply only water proofing compound, complete all as specified and directed.
100Material and labour for APP polymeric water proofing membrane minimum 3 mm thick and weighting not less than 3 kg/sqm of Make:-STP Texsa Ltd or hyper plas (Polyster),black finish reinforced with non-woven polyster matt (Weight not less than 150 gms/Sqm) with thermo fusible finish laid over compatible bitumen primer at the rate of 0.40 Ltr /Sqm torching over laps with a propane or abutan gas torch with a over lap of 75 mm at the side and 100 mm at the ends and sealing including applying a coat of cold emulsion bituminious primer all as per manufacturers instructions including preparation of surface complete all as specified and directed by Engr-in-Charge. Note:-(i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing. (ii) 10% amount of the total amount of water proofing treatment shall be retained as a guarantee for 1 to 10 years and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE.If contractor fail to rectify the defect pointed out during this period in writing,the defect shall be got rectified at contractor"risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee.Contractor"s quoted rate for this item shall deemed to be inclusive of this aspect.
101Cutting groove in parapet wall 75 mm wide and 65 mm deep,complete all as specified and directed.
102Cutting out cracks to V-section in existing roofs or terracing up to 25 mm depth, cleaning out, and filling solidly with a tarplastic sealing comound after applying shalitex primer complete all as specified and directed.
103Excavation in trenches not exceeding1.5 m wide & not exceeding 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes, forming of bottom for laying cable etc n.exc 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loosesoil complete all as specified and directed.
104Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25cm in soft/loose soil, complete all as specified and directed.
105Removing excavated material n.exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
106M&L for Cement concrete in foundations, filling and mass concrete (PCC) Type D2 1:4:8 (using 40 mm graded mechanically crushed stone aggregate) etc complete all as specified & as directed
107M&L for TMT bars 10mm dia & over cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends & binding with & including mild steel wire (not less than 0.9 mm dia) or securing with clips quality conforming all as specified & as directed
108All as per BOQ srl item N0. 107.00 here-in-above but 6 to 8mm dia, complete all as specified and directed.
109M&L for RCC M-25(using 20mm graded mechanically crushed stone aggregate) for foundation including rafts, footings, foundation beams, plinth beams, bases for columns, etc, complete all as specified and directed.
110M&LforRCC M-25(using 20mm graded mechanically crushed stone aggregate) for columns, pillars, pierrs, posts & struts etc complete all as specified and directed.
111M&L forRCC M-25(using 20mm graded mechanically crushed stone aggregate) for beams cantilevers bressumers, lintels over 1.5m span etc complete all as specified and directed.
112M&L for RCC M-25(using 20mm graded mechanically crushed stone aggregate)Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete as specified and directed
113M&L for Formwork to soffits of suspendedslabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed.
114M&L for flat form work to sides of concrete foundations, footing bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams and similar work, veritical or to batter all as specified & complete all as specified and directed.
115M&L form work to sides of pillars posts, struts piers, columns & stanchions square rectangular or polygonal fair finished surfaces in shape complete all as specified and directed.
116M&L for flat form work to sides and soffits of floors or roof beams haunching, girders bressumers lintel cantilevers shelves including supports, overhangs etc also splays between floors and beams etc complete all as specified and directed.
117M&L for Formwork to edges of concrete flats (rough finished surface of concrete), treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exceeding 20cm wide, complete all as specified and directed
118M & L for PCC 1:4:8, type D2, (using 40 mm graded mechanically crushed stone aggregate) 75 mm thick as in sub base of floor complete all as specified and directed.
119Material and labour 75mm thick PCC 1:3:6 Type C1 (using 20mm graded mechanically crushed stone aggregate) as in path, pavings, floors etc. finished even and smooth without using extra cementcomplete incl 3mm thick glass/metal strip in expansion joints,complete all as specified and as directed by Engineer-in-Charge.
120Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed
121M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
122M&L for point wiring (concealed type) 1.5 Sqmm single core PVC insulated FRLS unsheathed 1100 volts grade copper conductor multi-stranded cables drawn through non - metallic rigid PVC conduits and conduit accessories and provision of one run ofPVC insulated FRLS unsheathed 1100 volts grade copper conductor multi-stranded single core cable of size 1.5 sqmm and connected to common earth dolly including provision of suitable size of modular metal box flush in wall with and including white colour cover plates for mounting modular type switches, sockets, fan regulators, bell pushes etc. for one light point, ceiling fan, Exhaust fan controlled by one switch 1 way complete all as specified and as directed.
123All as per BOQ srl item No.122.00 here-in-above but for One 05 Amps socket outlet on independent board, complete all as specified and as directed.
124All as per srl item No.122.00 here-in-above but for One 05 Amps socket outlet on the same board with other switches, complete all as specified and as directed.
125All as per srl item No. 122.00 here-in-above but wiring with 2.5 Sqmm single core PVC insulated FRLS unsheathed 1100 volt grade copper conductor andwith one run of copper conductor PVC insulated multi-stranded cable 2.5 Sqmm for earth continuity conductor and connecting to common earth dolly, complete for one 15 Amps power socket point on independent board complete all as specified and as directed.
126All as per item No. 3 above but wiring with 4 Sqmm single core PVC insulated FRLS unsheathed 1100 volt grade copper conductor andwith one run of copper conductor PVC insulated multi-stranded cable 4 Sqmm for earth continuity conductor and connecting to common earth dolly, complete for one 15 Amps power socket point on independent board complete all as specified and directed
127M&L for sub main wiring with 2 runs of single core PVC insulated FRLS unsheathed multi-stranded copper conductor cables of size 6 sqmm drawn through and including non - metallic rigid PVC conduits of suitable size with all necessary fittings and provision of one run of 6 sqmm PVC insulated unsheathed multistranded copper conductor single core for earth continuity and connected to common earth dolly, complete all as specified and directed. Note: Two runs of 6sqmm cable, one run of 6 sqmm earth conductor cable and one run of PVC casing and caping shall be measured and paid together as one unit length.
128M & L for modular switch 1 way 6A, 230 Volts, 1 module, complete all as specified and as directed.
129M & L for Modular socket, 6A-2/3 pin 2 module, complete all as specified and as directed.
130M & L for modular switch 1 Way 16A, 230 volts, 1 module, complete all as specified and as directed.
131M & L for modular socket 6/16A, 2/3 pin 2 module, complete all as specified and as directed.
132S&F ceiling rose, PVC body, 3 terminal suitable for 230 volts AC supply, complete all as specified and directed.
133M & L for modular fan regulator electronic step type,2 module, 230 Volts, suitable for 1200 mm sweep ceiling fan, complete all as specified and directed.
134Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
135Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
136Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
137Supply and fixing LED Bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
138Taking down fan, regulator, sealing cable end, dismantling blades and removing fan and blades to store and M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and Hanging only ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed
139Taking down fan,cable end, dismantling blades and removing fan and blades to store and M&L for Painting of exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and Fixing only exhaust fan (M.D.supply) and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed
140M&L for rewinding of following fans with same gauge of super enameled copper wire complete,varnishing ,baking , connecting properly with sleeves assembling the same including replacement of unserviceable shackle and clamps with nots /bolts/washer /split pin and blade screws etc testing,complete all as specified and directed. NOTE: The quoted rates shall be deemed to include Spare parts like bearing, capacitor, bushes if required and reassembling after repair /replacement of worn out parts
141Ceiling fan 1200 /1400 mm sweep, complete all as specified and as directed.
142Exhaust fan 300 mm sweep, complete all as specified and as directed.
143S&F MCB DB TPN 4 way with, 415 V, double door type and including flush in wall to fix the MCB DB, complete all as specified and as directed.
144Supply and fixing TPN 16 To 32 AMP 415V 10KA "C" curve miniature circuit breaker (MCB) and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
145S&F sheet metal enclosures for MCB distribution board 230V, SPN, 8 way, double door type flushed inside wall with 200A rated bus bar and making good the disturbed surfaces complete all as specified and as directed
146Supply and fixing SPN 32 Amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB)and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed
147Supply and fixing 240V, 10 KA "C" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed
148M&L for earthing with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m below normal GL with the top edge of the plate not less then 1.5 m below the normal GL connected to GI wire 4mm dia protected by 15mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) and chamber with PCC (1:4:8) type D2 using 40mm graded mechanically crushed stone aggregate, coping with (1:3:6) type CI using 20mm graded mechanically crushed stone aggregate and with RCC pit cover (50 mm thick) in 1:2:4 type B1 using 20mm stone aggregate, reinforced with 8mm for MS bar at 80mm c/c both way in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate No 3 of SSR Part I and including charcoal dust, common salt and earth lead connected to earthing test point testing of earthing including takingdown/up existing unserviceable earthing accessories and dispose off from site deppsited complete all as specified and directed. Notes: (i) Cost of Earth strip/wire and GI pipe for protection of earth wire/strip upto 7.50 metre shall be deemed to be included in the quoted rate. (ii) On testing if the desired earth resistance is not obtained, entire earthing shall be re-done by contractor/ till desired earth resistance is not obtained without accruing any extra cost to department. (iii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode. (iv) Value of Earth resistance shall not be more than 5.0 Ohm
149Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc, complete all as specified and as directed.
150M&L for filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning downie 18cm only shall be measured for payment.
151Supply and laying well burnt fire Bricks of size 230x115x75 mm, locally available best quality (sub class "B" bricks) laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
152M&L for Pipe galvanised (Light grade) 50 mm bore dia, laid in trenches or fixed to pole with necessary MS Clamps, bolts, nuts, washers etc complete as in protection of UG cable complete all as specified and directed.
153Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core, complete all as specified and as directed.
154Taking out/ up/ downold unserviceable LT UG cable from trenches, walls, under roads of any size and capacity, complete all as specified and as directed.