Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #42455242

Tender For Hvac Work At Advanced Optics Laser Lab In Rrcat, Indore

Issued by Boards / Undertakings / PSU · indore, Madhya Pradesh
Tender Value
93.10 Lakhs
Estimated cost
Bid Submission
22 Mar 2024
0 days left
EMD
1.86 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
indore → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Hvac Work At Advanced Optics Laser Lab In Rrcat, Indore; Air Handling Unit: Design, Fabrication, Supply, Installation, Testing & Commissioning Of Double Skin Air Handling Unit ( Ahu ) Constructed From Outer Skin With 1Mm Thick Precoated G.I. Sheet ( Of Minimum 180 Gsm ) &1Mm Thick Inner G.I. Sheet ( Of Minimum 180 Gsm ) With 50Mm Thick Injected Puf Insulation Of 40 Kg / M3 Approx. Withthermal Break Profile Complete With Aluminium Extruded Framework Structural Section For Vrf Condensing Units And Comprising Of Following Sections: A. Mixing Chamber For Fresh Air & Return Air With Volume Controldampers.B. Pre Filter Section With G4 Filter As Per En779c. Cooling Coil Section With 6 Rows Deep Cooling Coil Suitable For Above Vrf Condensing Units With Cooling Option, Necessary Expansion & Communication Kits Compatible For Connection Of Vrf Outdoor Units In Single / Multiple Formalong With 1 Mm Thick S.S. Drain Pan And Drain Outlet. Hydrophilic Coating Shall Be Provided On Cooling Coil. Drift Eliminator Shall Be Provided.D. Uv Lamps Section With Uv Lampse. Heater Section With Thyristor Controlled Re-Heaterf. Humidifier Section Complete With Required Water Heaters, Float Valve, Low Water Level Safety Switch, Piping And Necessary Fittings.G. Blower Section With Statically And Dynamically Balanced Direct Drive, Plug Fan And Squirrel Cage Induction Motor ( With Vfd ) Of Tefc Type Suitable For 3 -Phase, 400V, 50Hz Of Efficiency Class Ie3. The Winding Of Motor Shall Be Class F Insulated And Fully Tropicalised, Motor Shall Be Rated For Continuous Duty As Defined In Is: 325 For Blower With Adjustable Base Frame, Fitted On A Common Extrudedaluminium Channel Using Anti Vibration Mountings For Silent And Vibration Free Operation.H. Fine Filter Section With F9 Filter As Per En779i. Temperature Sensor And Rh Sensor With Transmitter Unit And Associated Cabling, Differential Pressure Transmitter To Maintain The Constant Flow Of Air In Different Choked Condition Of Filters, Differential Pressure Switches Across Fine And Pre-Filter For Monitoring The Condition Of The Respective Filterj. Flanged Connection At The Inlet & Outlet Of Ahu With Volume Control Damper For Integrating To The Main Duct Lines.L. Suitable Inspection Doors For Filter, Coil & Blower Sections.M. Suitably Rated Antivibration ( Cushyfoot ) Mountings For Ahu Installation.Including All Other Components And Accessories Required For Proper Operation Of Ahu And To Achieve Required Temperature ( 25 ± 1°C ) And Relative Humidity ( 50% ± 10 % ) As Per Tender Specifications In Following Capacity:Ahu / 22000 Cfm / 56 Tr / 80 Mm Wg. S.P. 2 Vrf Outdoor Units: Design, Supply, Installation, Testing & Commissioning Of 28 Hp Modulating Outdoor / Condensing Units Withcooling Option Complete With Hermetically Sealed Dc Inverter / Digital Scroll Compressors, Condenser Coils, Variable Speed Condenser Fan With Motor, Microprocessor Controller Etc. The Unit Shall Include The Necessary Expansion & Communication Kits Compatible For Connection Of Vrf Outdoor Units With Ahu Mentioned Above In Single / Multiple Form. The Units Should Be Operated On Refrigerant - R410a. The Condensing Units Will Be Installed At Suitable Place For Compact Run Of Piping Along With Ms Raised Stand With Vibration Isolation Pads As Per Drawing And Technical Specifications. 3 Inter-Connected Copper Refrigerant Piping For Vrf System: Hard Drawn Copper Refrigerant Piping Of 18 G In Brazed Construction Between Ahu & Vrf Outdoor / Condensing Units With Class O Nitrile Rubber Insulation With Aluminium Foil ( 19 Mm Thick ) , 16 G. G.I. Perforated Tray For Refrigerant Piping & Cabling Etc. Of Various Widths With Support & Clamps Etc. Required For Proper Installation, Operation And Controls Of The Units ( The Average Running Distance Between Vrf Condensing / Outdoor Units And Ahu Shall Be Approximately 20 Meters ) .All Pipings Shall Be Pressure Tested For 48 Hrs. Pressure Hold Test Atminimum 1.5 Times The Working Pressure. Suitable Weight Bearing Supports Shall Be Planned For All Vertical Headers / Pipe Networks. 4 Condensate Drain Water Piping And Humidifier Connection Piping: Supply, Installation & Testing Of 40 Mm Dia. Cpvc Rigid Condensate Drain Pipes Of Class Sdr 11 With U Trap Complete From Ahu To Nearest Drain Pointas Per Tender Specification. 5 Electrical Panel For Ahu With Condensing Units: Design, Supply, Installation, Testing & Commissioning Of Indoor Floor / Wall Mounted Ip 42 Factory Built, Modular , Sectionalised, Compartimised, Extendable Type Lt Cubicle Panel Of Suitable Size Suitable For Operationon 433 / 415 V, 50Hz Ac 3 Phase Supply System Fabricated From Crca Sheet Steel Of 2Mm Thick For Frame Work And Cover, 3Mm Thick For Gland Plates With Stiffeners Wherever Required Having Vibration Free Structure Chemically Treated With Seven Tank Or Better Process For Above Air Handing Unit With Condensing Units As Per Tender Specification. 6 Microprocessor Based Electrical Control Panel Of Ip20 Or Better: Design, Supply, Installation, Testing & Commissioning Of Standalone Bacnet / Ip Based Modular Type, Bms Compatible Ddc Controller / Automation Station Having Integral Web Browser With I / O Module, Flash Memory For Programmed Logic Storage, Communication Port Etc. For Above Ahucontrol, Monitoring, Status Indication, Data Logging Etc. As Per Tender Specification. It Includes Controller, Associated Power Supply, Digital And Analog I / O Modules, Associated Enclosure, Wiring, Cabling Etc. 7 Lt Power Cabling: Installation, Testing And Commissioning Of Following 1.1 Kv, Copper Conductor, Xlpe Insulated, Pvc Sheathed Frls Cables As Per Tender Specifications. 8 3.5C X 25 Sq. Mm Copper Conductor Cable 9 3.5C X 10 Sq. Mm Copper Conductor Cable 10 3.5C X 6 Sq. Mm Copper Conductor Cable 11 3.5C X 2.5 Sq. Mm Copper Conductor Cable 12 End Termination Of Lt Cables: End Termination Of Following Copper Conductor, Xlpe Insulated, Pvc Sheathed Cables With Copper Lugs, Single Compression Type Brass Glands, Earthing Etc.By Using Nickel Plated Brass Gland, Copper Lug And Earth Clamps Duly Connected To The Equipment Ground Through Copper Conductor As Per Tender Specifications. 13 3.5C X 25 Sq. Mm Copper Conductor Cable 14 3.5C X 10 Sq. Mm Copper Conductor Cable 15 3.5C X 6 Sq. Mm Copper Conductor Cable 16 3.5C X 2.5 Sq. Mm Copper Conductor Cable 17 G.I. Ducting Works : Design, Fabrication, Supply, Installation, Testing & Commissioning Of Prefab.180 Gsmg.I. Sheet Metal Work As Per Specifications And Drawings. All Ducts Shall Be Fabricated Out Of Gss Confirming To Is: 277 And Shall Be Soft Annealed Quality. 18 1 Mm 19 1.2 Mm 20 Gss Fresh Airarrangement With Cowl, Bird Screen Etc. 21 Class O Duct Thermal Insulation: Thermal Insulation Of Ducts With Class ‘O’ Closed Cell Nitrile Rubber Having Thickness Of 25 Mm For Supply And Return Airduct As Per The Tender Specifications With 24 G Thickness Aluminium Cladding. Thermal Conductivity Of Insulation Material Shall Not Exceed 0.038 W / ( M.K ) Atmean Temperature Of 20 Deg.C As Per En 12667. 22 G. I. Duct Dampers: Suppy, Installation, Testing And Commissioning Of Rectangular Duct Damper Of Opposed Blade Type Duly Aluminium Painted As Per Tender Specification 23 Fire Damper With Actuator: Suppy, Installation, Testing And Commissioning Of Electrically Operated Damper With Compatible Actuator, Associated Cabling, Mounting Arrangement Etc. On Air Ducts As Per Tender Specifications. 24 Design, Fabrication, Supply, Installation, Testing & Commissioning Of Prefab.180 Gsmg.I. Sheet Metal Work As Per Specifications And Drawings. All Ducts Shall Be Fabricated Out Of Gss Confirming To Is: 277 And Shall Be Soft Annealed Quality. 25 2000 Mm X 750 Mm 26 2250 Mm X 800 Mm 27 Four Way Square Ceiling Duffuser: Supply, Installation, Testing & Commissioning Of Extruded Powder Coated Aluminium Diffuser With Key Operated Opposed Blade Damper Volume Control Damper As Per Tender Specification. A Special Model Of Square Ceiling Diffusers For Suiting In A Metal Ceiling Module Size Of 600 X 600 Mm 28 Return Grill: Supply, Installation, Testing & Commissioning Of Extruded Powder Coated Aluminium Return Air Grilles With Volume Control Damper As Per Tender Specification. 29 Supply, Installation, Testing And Commissioing Of Data Logging Temperature-Humidity Monitor Having I ) Temperature Measurement Range / Resolution: -20° To 70°C / 0.1° Ii ) Temperature Measurement Accuracy: ±1.2°F ( ±0.6°C ) Iii ) Rh Measurement Range / Resolution: 5 To 95% / 0.1%Rhiv ) Rh Measurement Accuracy: ±3% From 10 To 90%Rh; ±5% Elsewhere In Range 30 Supply, Fabrication & Fixing Of M.S. Structural Work Including Angle / Channel Frames / Supports Etc. And Finally Painted With Two Coats Of Red Oxide And Two Coat Of Enamel Paints Of Required Colour As Per Tender Specifications.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-Mar-2024

BOQ

Name of work: HVAC work atAdvanced Optics Laser lab in RRCAT, Indore
Sl. No. Item Description
1Air Handling Unit: Design, fabrication, supply, installation, testing & commissioning of Double Skin Air Handling Unit (AHU) constructed from outer skin with 1mm thick precoated G.I. sheet (of minimum 180 GSM) &1mm thick inner G.I. sheet (of minimum 180 GSM) with 50mm thick injected PUF insulation of 40 kg/m3 approx. withthermal break profile complete with aluminium extruded framework structural section for VRF condensing units and comprising of following sections: a. Mixing chamber for Fresh Air & Return Air with volume controldampers.b. Pre filter section with G4 filter as per EN779c. Cooling coil section with 6 rows deep cooling coil suitable for above VRF condensing units with Cooling option, necessary Expansion & Communication Kits compatible for connection of VRF outdoor units in single / multiple formalong with 1 mm thick S.S. drain pan and drain outlet. Hydrophilic coating shall be provided on cooling coil. Drift eliminator shall be provided.d. UV lamps section with UV lampse. Heater section with thyristor controlled re-heaterf. Humidifier section complete with required water heaters, float valve,low water level safety switch, piping and necessary fittings.g. Blower section with statically and dynamically balanced direct drive, Plug fan and Squirrel cage induction motor (with VFD) of TEFC type suitable for 3 -phase, 400V, 50Hz of efficiency class IE3. The winding of motor shall be class \"F\" insulated and fully tropicalised, motor shall be rated for continuous duty as defined in IS: 325 for blower with adjustable base frame, fitted on a common extrudedAluminium channel using anti vibration mountings for silent and vibration free operation.h. Fine filter section with F9 filter as per EN779i. Temperature sensor and RH sensor with transmitter unit and associated cabling, differential pressure transmitter to maintain the constant flow of air in different choked condition of filters, differential pressure switches across fine and pre-filter for monitoring the condition of the respective filterj. Flanged connection at the inlet & outlet of AHU with volume control damper for integrating to the main duct lines.l. Suitable inspection doors for filter, coil & blower sections.m. Suitably rated antivibration (Cushyfoot) mountings for AHU installation.Including all other components and accessories required for proper operation of AHU and to achieve required temperature (25 ± 1°C) and relative humidity (50% ± 10 %) as per tender specifications in following capacity:AHU/22000 CFM /56 TR/80 mm WG. S.P.
2VRF Outdoor Units: Design, supply, installation, testing & commissioning of 28 HP Modulating Outdoor / Condensing units withCooling Option complete with hermetically sealed DC Inverter / Digital Scroll Compressors, Condenser coils, variable speed condenser fan with motor, Microprocessor Controller etc. The unit shall include the necessary expansion & communication kits compatible for connection of VRF outdoor units with AHU mentioned above in single / multiple form. The units should be operated on Refrigerant - R410A. The condensing units will be installed at suitable place for compact run of piping along with MS raised stand with vibration isolation pads as per drawing and technical specifications.
3Inter-connected Copper Refrigerant piping for VRF System: Hard drawn copper refrigerant piping of 18 G in brazed construction between AHU & VRF Outdoor / Condensing units with class \"O\" nitrile rubber insulation with Aluminium foil (19 mm thick), 16 G. G.I. perforated tray for Refrigerant piping & cabling etc. of various widths with support & clamps etc. required for proper installation, operation and controls of the units (the average running distance between VRF Condensing/outdoor units and AHU shall be approximately 20 meters).All pipings shall be pressure tested for 48 hrs. pressure hold test atminimum 1.5 times the working pressure. Suitable weight bearing supports shall be planned for all vertical headers / pipe networks.
4Condensate Drain Water Piping and humidifier connection Piping: Supply, installation & testing of 40 mm dia. CPVC rigid condensate drain pipes of class SDR 11 with \"U\" trap complete from AHU to nearest drain pointas per tender specification.
5Electrical Panel for AHU with condensing units: Design, Supply, installation, testing & commissioning of indoor floor/wall mounted IP 42 factory built, modular ,sectionalised, compartimised, extendable type LT cubicle panel of suitable size suitable for operationon 433/415 V, 50Hz AC 3 phase supply system fabricated from CRCA sheet steel of 2mm thick for frame work and cover, 3mm thick for gland plates with stiffeners wherever required having vibration free structure chemically treated with seven tank or better process for above air handing unit with condensing units as per tender specification.
6Microprocessor based electrical control panel of IP20 or better: Design, Supply, installation, testing & commissioning of standalone BACnet/IP based modular type, BMS compatible DDC controller/automation station having integral web browser with I/O module, flash memory for programmed logic storage, communication port etc. for above AHUcontrol, monitoring, status indication, data logging etc. as per tender specification. It includes controller, associated power supply, digital and analog I/O modules, associated enclosure, wiring, cabling etc.
7LT Power Cabling: Installation, testing and commissioning of following 1.1 kV, copper conductor, XLPE insulated, PVC sheathed FRLS cables as per tender specifications.
83.5C x 25 sq. mm copper conductor cable
93.5C x 10 sq. mm copper conductor cable
103.5C x 6 sq. mm copper conductor cable
113.5C x 2.5 sq. mm copper conductor cable
12End termination of LT cables: End termination of following copper conductor, XLPE insulated, PVC sheathed cables with copper lugs, single compression type brass glands, earthing etc.by using Nickel Plated Brass Gland, copper Lug and earth clamps duly connected to the equipment ground through Copper conductor as per tender specifications.
133.5C x 25 sq. mm copper conductor cable
143.5C x 10 sq. mm copper conductor cable
153.5C x 6 sq. mm copper conductor cable
163.5C x 2.5 sq. mm copper conductor cable
17G.I. Ducting Works : Design, fabrication, supply, installation, testing & commissioning of Prefab.180 GSMG.I. sheet metal work as per specifications and drawings. All ducts shall be fabricated out of GSS confirming to IS: 277 and shall be soft annealed quality.
181 mm
191.2 mm
20GSS Fresh Airarrangement with Cowl, bird screen etc.
21Class \"O\" Duct Thermal Insulation: Thermal insulation of Ducts with Class ‘O’ Closed Cell Nitrile Rubber having thickness of 25 mm for Supply and return AirDuct as per the tender specifications with 24 G thickness aluminium cladding. Thermal conductivity of insulation material shall not exceed 0.038 W/(m.K) atmean temperature of 20 deg.C as per EN 12667.
22G. I. Duct Dampers: Suppy, installation, testing and commissioning of Rectangular duct damper of opposed blade type duly aluminium painted as per tender specification
23Fire damper with Actuator: Suppy, installation, testing and commissioning of electrically operated damper with compatible actuator, associated cabling, mounting arrangement etc. on air ducts as per tender specifications.
24Design, fabrication, supply, installation, testing & commissioning of Prefab.180 GSMG.I. sheet metal work as per specifications and drawings. All ducts shall be fabricated out of GSS confirming to IS: 277 and shall be soft annealed quality.
252000 mm x 750 mm
262250 mm x 800 mm
27Four way square ceiling duffuser: Supply, installation, testing & commissioning of Extruded powder coated Aluminium diffuser with key operated opposed blade damper volume control damper as per tender specification. A special model of square ceiling diffusers for suiting in a metal ceiling module size of 600 x 600 mm
28Return grill: Supply, installation, testing & commissioning of Extruded powder coated Aluminium return air grilles with volume control damper as per tender specification.
29Supply, Installation, testing and commissioing of Data Logging Temperature-Humidity Monitor having i) Temperature measurement range/resolution: -20° to 70°C/0.1° ii) Temperature measurement accuracy: ±1.2°F (±0.6°C)iii) RH measurement range/resolution: 5 to 95%/0.1%RHiv) RH measurement accuracy: ±3% from 10 to 90%RH; ±5% elsewhere in range
30Supply, fabrication & fixing of M.S. structural work including angle/channel frames/supports etc. and finally painted with two coats of Red oxide and two coat of enamel paints of required colour as per tender specifications.

AI Tender Summary

OUR REF NO 42455242
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 93.10 Lakhs
LAST DATE 22-03-2024
Authority
Authority Name Raja Ramana Centre For Advance Technology
Work Description Tender For Hvac Work At Advanced Optics Laser Lab In Rrcat, Indore; Air Handling Unit: Design, Fabrication, Supply, Installation, Testing & Commissioning Of Double Skin Air Handling Unit ( Ahu ) Constructed From Outer Skin With 1Mm Thick Precoated G.I. Sheet ( Of Minimum 180 Gsm ) &1Mm Thick Inner G.I. Sheet ( Of Minimum 180 Gsm ) With 50Mm Thick Injected Puf Insulation Of 40 Kg / M3 Approx. Withthermal Break Profile Complete With Aluminium Extruded Framework Structural Section For Vrf Condensing Units And Comprising Of Following Sections: A. Mixing Chamber For Fresh Air & Return Air With Volume Controldampers.B. Pre Filter Section With G4 Filter As Per En779c. Cooling Coil Section With 6 Rows Deep Cooling Coil Suitable For Above Vrf Condensing Units With Cooling Option, Necessary Expansion & Communication Kits Compatible For Connection Of Vrf Outdoor Units In Single / Multiple Formalong With 1 Mm Thick S.S. Drain Pan And Drain Outlet. Hydrophilic Coating Shall Be Provided On Cooling Coil. Drift Eliminator Shall Be Provided.D. Uv Lamps Section With Uv Lampse. Heater Section With Thyristor Controlled Re-Heaterf. Humidifier Section Complete With Required Water Heaters, Float Valve, Low Water Level Safety Switch, Piping And Necessary Fittings.G. Blower Section With Statically And Dynamically Balanced Direct Drive, Plug Fan And Squirrel Cage Induction Motor ( With Vfd ) Of Tefc Type Suitable For 3 -Phase, 400V, 50Hz Of Efficiency Class Ie3. The Winding Of Motor Shall Be Class F Insulated And Fully Tropicalised, Motor Shall Be Rated For Continuous Duty As Defined In Is: 325 For Blower With Adjustable Base Frame, Fitted On A Common Extrudedaluminium Channel Using Anti Vibration Mountings For Silent And Vibration Free Operation.H. Fine Filter Section With F9 Filter As Per En779i. Temperature Sensor And Rh Sensor With Transmitter Unit And Associated Cabling, Differential Pressure Transmitter To Maintain The Constant Flow Of Air In Different Choked Condition Of Filters, Differential Pressure Switches Across Fine And Pre-Filter For Monitoring The Condition Of The Respective Filterj. Flanged Connection At The Inlet & Outlet Of Ahu With Volume Control Damper For Integrating To The Main Duct Lines.L. Suitable Inspection Doors For Filter, Coil & Blower Sections.M. Suitably Rated Antivibration ( Cushyfoot ) Mountings For Ahu Installation.Including All Other Components And Accessories Required For Proper Operation Of Ahu And To Achieve Required Temperature ( 25 ± 1°C ) And Relative Humidity ( 50% ± 10 % ) As Per Tender Specifications In Following Capacity:Ahu / 22000 Cfm / 56 Tr / 80 Mm Wg. S.P. 2 Vrf Outdoor Units: Design, Supply, Installation, Testing & Commissioning Of 28 Hp Modulating Outdoor / Condensing Units Withcooling Option Complete With Hermetically Sealed Dc Inverter / Digital Scroll Compressors, Condenser Coils, Variable Speed Condenser Fan With Motor, Microprocessor Controller Etc. The Unit Shall Include The Necessary Expansion & Communication Kits Compatible For Connection Of Vrf Outdoor Units With Ahu Mentioned Above In Single / Multiple Form. The Units Should Be Operated On Refrigerant - R410a. The Condensing Units Will Be Installed At Suitable Place For Compact Run Of Piping Along With Ms Raised Stand With Vibration Isolation Pads As Per Drawing And Technical Specifications. 3 Inter-Connected Copper Refrigerant Piping For Vrf System: Hard Drawn Copper Refrigerant Piping Of 18 G In Brazed Construction Between Ahu & Vrf Outdoor / Condensing Units With Class O Nitrile Rubber Insulation With Aluminium Foil ( 19 Mm Thick ) , 16 G. G.I. Perforated Tray For Refrigerant Piping & Cabling Etc. Of Various Widths With Support & Clamps Etc. Required For Proper Installation, Operation And Controls Of The Units ( The Average Running Distance Between Vrf Condensing / Outdoor Units And Ahu Shall Be Approximately 20 Meters ) .All Pipings Shall Be Pressure Tested For 48 Hrs. Pressure Hold Test Atminimum 1.5 Times The Working Pressure. Suitable Weight Bearing Supports Shall Be Planned For All Vertical Headers / Pipe Networks. 4 Condensate Drain Water Piping And Humidifier Connection Piping: Supply, Installation & Testing Of 40 Mm Dia. Cpvc Rigid Condensate Drain Pipes Of Class Sdr 11 With U Trap Complete From Ahu To Nearest Drain Pointas Per Tender Specification. 5 Electrical Panel For Ahu With Condensing Units: Design, Supply, Installation, Testing & Commissioning Of Indoor Floor / Wall Mounted Ip 42 Factory Built, Modular , Sectionalised, Compartimised, Extendable Type Lt Cubicle Panel Of Suitable Size Suitable For Operationon 433 / 415 V, 50Hz Ac 3 Phase Supply System Fabricated From Crca Sheet Steel Of 2Mm Thick For Frame Work And Cover, 3Mm Thick For Gland Plates With Stiffeners Wherever Required Having Vibration Free Structure Chemically Treated With Seven Tank Or Better Process For Above Air Handing Unit With Condensing Units As Per Tender Specification. 6 Microprocessor Based Electrical Control Panel Of Ip20 Or Better: Design, Supply, Installation, Testing & Commissioning Of Standalone Bacnet / Ip Based Modular Type, Bms Compatible Ddc Controller / Automation Station Having Integral Web Browser With I / O Module, Flash Memory For Programmed Logic Storage, Communication Port Etc. For Above Ahucontrol, Monitoring, Status Indication, Data Logging Etc. As Per Tender Specification. It Includes Controller, Associated Power Supply, Digital And Analog I / O Modules, Associated Enclosure, Wiring, Cabling Etc. 7 Lt Power Cabling: Installation, Testing And Commissioning Of Following 1.1 Kv, Copper Conductor, Xlpe Insulated, Pvc Sheathed Frls Cables As Per Tender Specifications. 8 3.5C X 25 Sq. Mm Copper Conductor Cable 9 3.5C X 10 Sq. Mm Copper Conductor Cable 10 3.5C X 6 Sq. Mm Copper Conductor Cable 11 3.5C X 2.5 Sq. Mm Copper Conductor Cable 12 End Termination Of Lt Cables: End Termination Of Following Copper Conductor, Xlpe Insulated, Pvc Sheathed Cables With Copper Lugs, Single Compression Type Brass Glands, Earthing Etc.By Using Nickel Plated Brass Gland, Copper Lug And Earth Clamps Duly Connected To The Equipment Ground Through Copper Conductor As Per Tender Specifications. 13 3.5C X 25 Sq. Mm Copper Conductor Cable 14 3.5C X 10 Sq. Mm Copper Conductor Cable 15 3.5C X 6 Sq. Mm Copper Conductor Cable 16 3.5C X 2.5 Sq. Mm Copper Conductor Cable 17 G.I. Ducting Works : Design, Fabrication, Supply, Installation, Testing & Commissioning Of Prefab.180 Gsmg.I. Sheet Metal Work As Per Specifications And Drawings. All Ducts Shall Be Fabricated Out Of Gss Confirming To Is: 277 And Shall Be Soft Annealed Quality. 18 1 Mm 19 1.2 Mm 20 Gss Fresh Airarrangement With Cowl, Bird Screen Etc. 21 Class O Duct Thermal Insulation: Thermal Insulation Of Ducts With Class ‘O’ Closed Cell Nitrile Rubber Having Thickness Of 25 Mm For Supply And Return Airduct As Per The Tender Specifications With 24 G Thickness Aluminium Cladding. Thermal Conductivity Of Insulation Material Shall Not Exceed 0.038 W / ( M.K ) Atmean Temperature Of 20 Deg.C As Per En 12667. 22 G. I. Duct Dampers: Suppy, Installation, Testing And Commissioning Of Rectangular Duct Damper Of Opposed Blade Type Duly Aluminium Painted As Per Tender Specification 23 Fire Damper With Actuator: Suppy, Installation, Testing And Commissioning Of Electrically Operated Damper With Compatible Actuator, Associated Cabling, Mounting Arrangement Etc. On Air Ducts As Per Tender Specifications. 24 Design, Fabrication, Supply, Installation, Testing & Commissioning Of Prefab.180 Gsmg.I. Sheet Metal Work As Per Specifications And Drawings. All Ducts Shall Be Fabricated Out Of Gss Confirming To Is: 277 And Shall Be Soft Annealed Quality. 25 2000 Mm X 750 Mm 26 2250 Mm X 800 Mm 27 Four Way Square Ceiling Duffuser: Supply, Installation, Testing & Commissioning Of Extruded Powder Coated Aluminium Diffuser With Key Operated Opposed Blade Damper Volume Control Damper As Per Tender Specification. A Special Model Of Square Ceiling Diffusers For Suiting In A Metal Ceiling Module Size Of 600 X 600 Mm 28 Return Grill: Supply, Installation, Testing & Commissioning Of Extruded Powder Coated Aluminium Return Air Grilles With Volume Control Damper As Per Tender Specification. 29 Supply, Installation, Testing And Commissioing Of Data Logging Temperature-Humidity Monitor Having I ) Temperature Measurement Range / Resolution: -20° To 70°C / 0.1° Ii ) Temperature Measurement Accuracy: ±1.2°F ( ±0.6°C ) Iii ) Rh Measurement Range / Resolution: 5 To 95% / 0.1%Rhiv ) Rh Measurement Accuracy: ±3% From 10 To 90%Rh; ±5% Elsewhere In Range 30 Supply, Fabrication & Fixing Of M.S. Structural Work Including Angle / Channel Frames / Supports Etc. And Finally Painted With Two Coats Of Red Oxide And Two Coat Of Enamel Paints Of Required Colour As Per Tender Specifications.
Basic Detail
Tender No RRCAT/CSD/EEACS/2024/02
Bidding Type Tender
Location
City indore
State Madhya Pradesh
Key Dates
Publish Date 12 Mar 2024
Submission Date 22 Mar 2024
Open Date 25 Mar 2024
Finance
Tender Value 93.10 Lakhs
Tender Fee Ref. Documents
EMD 1.86 Lakhs
Exemption Not Available
Document List
1c85c893-f2c6-4aee-b254-39b40b0b350f.html
BOQ_837850.xls
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf
Tendernotice_5.pdf
Tendernotice_6.pdf
Tendernotice_7.pdf
Tendernotice_8.pdf
Tendernotice_9.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 12, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 22, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 22, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 25, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

1c85c893-f2c6-4aee-b254-39b40b0b350f.html

xls

BOQ_837850.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

pdf

Tendernotice_5.pdf

pdf

Tendernotice_6.pdf

pdf

Tendernotice_7.pdf

pdf

Tendernotice_8.pdf

pdf

Tendernotice_9.pdf

TenderDetail
Loading tenders