Tender For Community Hall Murgi Mohalla Chander Nagar
Tender Value
34.99 Lakhs
Estimated cost
Bid Submission
04 Mar 2024
0 days left
EMD
70000
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
batala → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Community Hall Murgi Mohalla Chander Nagar
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavationin foundations,trenches etc. in all kinds of soil where pick jumperwork is not involvedand not exceeding 2.0 metres depth including dressing of bottom and sidesoftrenches, stackingthe excavated soil clearfrom the edge ofexcavationand subsequent filling aroundmasonryin 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 2 | Cement concrete 1:6:12 With with Stone Ballast 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 3 | Centring and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 4 | Reinforcedcementconcrete M-20mechanicalybatch mixed usingbatch type concrete mixeras per IS:1791and vibrated by needlevibratorbut excluding steel reinforcementcentring and shuttering in foundation and plinth. |
| 5 | Damp proof course 4cm thick of cementconcrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded |
| 6 | First classburntbrick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 7 | Centringand shutteringforsidesand soffitsofbeam, beams launchings girders bressumers, lintels |
| 8 | First class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level |
| 9 | Centringand shutteringfor flatsurfacessuch as suspended floors, roofs, landings, chajjas, shelves etc. |
| 10 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. |
| 11 | 12.5mm thick cement plaster 1:4 |
| 12 | 20mm thick cement plaster 1:5in Two Coat |
| 13 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as perspecifications and to the entire satisfaction of Engineer-in- charge. (If fixed on wall face clamp to be paid separatly as per respective item) |
| 14 | Providing andfixing 110mmdiaSWRU.P.V.C bend forRain water pipe as per IS:14735including jointing complete as per specificationsand to the entiresatisfactionofEngineer-in- charge. |
| 15 | Providing and fixing 110 mm diaSWR U.P.V.C Coupling/SocketeforRain water pipeas per IS:14735 includingjointingcompleteas per specificationsand to the entire satisfaction of Engineer- in- charge. |
| 16 | Top khurra0.6mx0.6m for rainwater pipein 25mmthick cementconcrete1:2:4over50mmthick cementconcrete 1:8:16. |
| 17 | Bottom Khurra on ground 1.2m. x 0.6m. consisting ofbrick on-edgelaid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. |
| 18 | Terracingconsistingoftiles22.86 cm x11.43 cm x3.81 cm laid over25mmmudplaster,75mmmudfilling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement |
| 19 | Cementconcrete 1:2:4 gola10cm x10cm concave quadrant along junction of roofswithparapetwallfinished smooth, where specially specified. |
| 20 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 21 | Earthfilling under floorswithsurplus ordinary soilor soil containing gravel or kankarupto40%taking outside the premises in 15 cm layers incluidng ramming, watering and consolidated all lead . |
| 22 | Base course of floor consisting of 100mm thick cement concrete 1:8:16with stone Aggreegates 40mm Gauge and 100mm Fine sand filling using mechanical mixer for mixing of material. |
| 23 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by themanufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. |
| 24 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete |
| 25 | Factory manufacturedflushdoor fixed in positioniron hinges, etc (excluding thecost of anyfittings other than specified above but including labour forfixing the same in position 35 mm thick (Code : II Revision IS-2191 Part-I) 1973, Commercialwithelmor gurjanfacingon both\Sideswith laminated core and lipped edges:- 35mm Thick |
| 26 | Wire gauge Hollock wood door shutter without springs housed in chowkhat. 35mm thick as per PWD Specifications. |
| 27 | Providing & Fixing glass panes with nails and putty or wooden strip complete in all respect |
| 28 | Wrought iron and mild steelladders, framed grills, gratingetc. with ends of bars, riveted or welded or forged, framed window guards,barrediron doors, stair case,iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 29 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 550 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding, bending and placing in position complete |
| 30 | Preparation of plastered orconcretesurface forpainting (includingsandpapering thesurface)using readymixed cement based wall putty by applying two coats to get required finish |
| 31 | Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surface |
| 32 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two coats) |
| 33 | Painting two coats excluding priming coat with synthetic enemal paint using special quality paintin all shades on new wood work / metal work surface to give an even shade |
| 34 | Preparation of plywoodsurface for painting includingsand papering the surface and applying filling with approved quality fillers consistingofwhitelead,linseedoil, Varnish,and Chalk Mitti including finishing the surface to required finish complete. |
| 35 | Applyingpink primeroraluminumprimingcoat on wood work including preparation of surface knotting and stopping etc. |
| 36 | Painting two coats excluding priming coat with synthetic enemal paint using special quality paintin all shades on new wood work / metal work surface to give an even shade |
| 37 | Earthwork in excavationin foundations,trenches etc. in all kinds of soil where pick jumperwork is not involvedand not exceeding 2.0 metres depth including dressing of bottom and sidesoftrenches, stackingthe excavated soil clearfrom the edge ofexcavationand subsequent filling aroundmasonryin 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 38 | CementConcrete1:8:16with 40mmguagestoneaggregate mixing by mechanical means using concrete mixer volumetric type |
| 39 | First classburntbrick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 40 | Base course of floor consisting of 100mm thick cement concrete 1:8:16with stone Aggreegates 40mm Gauge and 100mm Fine sand filling using mechanical mixer for mixing of material. |
| 41 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of materia |
| 42 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufacturedby block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. |
| 43 | 12.5 mm thickcement plaster1:5completein all respect as per specifcation,drawingandto theentiresatisficationof Engineer-In-Charge. |
| 44 | Finishing walls with exterior decorative cement based paint such as snowcem, robbiacrem etc. two coat or more coat to give an even shade. |
| 45 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULARSWITCHES:WiringinPVC insulatedcopperconductorsinglecore FR cable (ISI marked), 1100volts grade to be laid in heavy gauge, uPVC, fire retardant conduit pipe 20mm/25mm dia. (2mm thick) ISI Marked, recessed in wall etc., complete with powdercoated/anodizedconcealedmetal boxesrequiredforsuitablenumberof modules, for having electronic fan regulators, bell push, electronic buzzer, 3pin 6Amp., 3pin 16/20Amp. Sockets and6Amp./16/20Amp. Switches (Screw Type Modular Accessories) etc., andcoveredwith Frame Plate etc., & includingthecostofrequirednumberof modular switches/sockets, step type electronic fan regulator 100watts, PVC connector (For Fan Box andElectronic Buzzer), Steel Hooks, Circular Inspection Box (Recessed Type and Deep Type) uPVC conduit pipe & copper wire and other petty material etc. including the cost of cutting and filling up of chases:- |
| 46 | Wiring lightpointinPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5 sq. mm, 1100volts grade. |
| 47 | Wiring fanpointwithsheet metalfanbox (shape hexagonal& sheetthickness notlessthan 1.60 mm) in PVC insulated copper conductor single core FR cable(ISI marked) overall1.5 sq. mm, 1100volts grade withsteptypeelectronic fan regulator 100watts. |
| 48 | Wiring 3 pin 6 Amp. wall socket(Shuttered) point in PVC insulated copper conductor singlecore FR cable(ISI marked) overall 1.5sq.mm,1100volts grade complete with bonding to existing earth with PVC insulatedcopperconductorsingle coreFR cable(ISImarked)overall 1sq.mm,1100volts grade. |
| 49 | Wiring3pin 16/20 amp. powerplug control (shuttered) and switch. |
| 50 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated single core FR copperconductor cable ISI marked left bare in pipe or casing of suitable size excluding the cost of supply and erection of pipe or casing. |
| 51 | PVC insulatedcopperconductorsingle coreFR cable(ISImarked)overall 1.5sq.mm,1100volts grade |
| 52 | PVC insulatedcopperconductorsingle coreFR cable(ISImarked)overall 2.5sq.mm,1100volts grade |
| 53 | PVC insulatedcopperconductorsingle coreFR cable (ISImarked)overall4sq.mm, 1100volts grade |
| 54 | PVC, HDPEPIPES &PVC FLEXIBLE PIPES:Supply& erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty materialas per PWD General Specifications 2010:- |
| 55 | Heavygauge PVC conduitpipe 25mmdia.(ISI marked 2mm thick)Flushed |
| 56 | Heavygauge PVC conduitpipe 40mmdia.(ISI marked 2mm thick)Flushed |
| 57 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erectionofswitches, sockets, power switchand sockets and other accessories(flushpianotype/ modular accessories)in the existingbakelite/modular cover frameincluding connections andpetty material etc. |
| 58 | Bakelite batten holder large size |
| 59 | MINIATURECIRCUITBREAKERS/RCBO\"s/RCCB\"s:Supplyanderection ofMiniature Circuit Breakers/ RCBO\"s/ RCCB\"s in the existing MCB distributionboardasperPWDGeneral Specifications 2010including connections with suitable size of thimbles/lugs. |
| 60 | Miniature circuit breaker singlepole6 to32amp. (Breakingcapacity10kA, Curve-C)suitable for 240/ 415 volts 50cycles AC supply |
| 61 | Miniaturecircuitbreaker doublepole 40amp. (Breaking capacity 10kA, Curve-C)suitable for 240/ 415 volts 50cycles AC supply |
| 62 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metaldouble door distribution boards of suitable size andof required no. of ways for mountingminiature circuit breakers/ RCBO\"s/ RCCB\"s intheexisting MCB distribution board as per PWD General Specifications 2010including connectionswith suitablesize ofthimblesand bonding to existing earth etc.GROUP-A: (Siemens |
| 63 | Sheet metal plugand socket distributionboard singlepoleMCB andneutral enclosure witha two pinandearth plugsocket toincorporate inone single pole MCB 20amp. |
| 64 | Supply & erection of ceiling fan suitable size 1200mm Sweep Model Velocity HS Perl white make Havell’s, Crompton, Bajaj including connection & testing complete in all respect as desire by the Engineer incharge of work at site with 5 star rating. |
| 65 | Supply and erection of Exhaust Fan 12” 300 mm Sweep Heavy Duty Turbo Force Havell’s, make Crompton, Bajaj Including connection & testing and Petty material Complete in all respects as desired by the Engineer incharge of work at site. |
| 66 | Supplyand erection ofSurfacemounted luminaire suitable for 2x PL-S11Watt with C R C A housing and decorative endcaps cat No. FCS0312xPL-S/2PIIW /240V at Philips makewith2xPL-52P 11 watt lamp including necessary connection & testing, complete inallrespect asper satisfaction of Engineer incharge at site and equivalent Wipro/Bajaj/Crompton Greaves. |
| 67 | Supplyand erection ofCFL lamp 14Watt Philips Make. |
AI Tender Summary
Tender Timeline
Feb 23, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedMar 04, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 04, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender