Tender For Repair / Maintenance Of Ceiling Fans, Exhaust Fans, Air Circulators , Desert Coolers And Connected Items At Patiala Mil Stn Under Ge (N) Patiala, patiala-Punjab

Military Engineer Services-MES has published Tender For Repair / Maintenance Of Ceiling Fans, Exhaust Fans, Air Circulators , Desert Coolers And Connected Items At Patiala Mil Stn Under Ge (N) Patiala. Submission Date for this Tender is 14-03-2024. Air Circulators Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

42428706
Tender For Repair / Maintenance Of Ceiling Fans, Exhaust Fans, Air Circulators , Desert Coolers And Connected Items At Patiala Mil Stn Under Ge (N) Patiala
Open Tender
Indian
Punjab
patiala
14-03-2024

Tender Details

Tender For Repair / Maintenance Of Ceiling Fans, Exhaust Fans, Air Circulators , Desert Coolers And Connected Items At Patiala Mil Stn Under Ge ( N ) Patiala

Key Value

Document Fees
INR 500 /-
EMD
INR 60200.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINT OF CEILING FANS, EXHAUST FANS, AIR CIRCULATORS, DESERT COOLERS AND CONNECTED ITEMS AT PATIALA MIL STN UNDER GE (N) PATIALA
Sl. No. Item Description
1Dismantling of ceiling fan 1200 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
2Dismantling of ceiling fan 1400 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
3Dismantling of wall mounting/Cabin fan 380/400mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
4Dismantling of industrial wall mounting air circulator fan 450/600mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
5Dismantling of exhaust fan 380/450mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
6Dismantling of exhaust fan 225/300 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins,body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed. Note for item No. 1.00 to 6.00 : It is the prime responsibility of EIC to ascertain the necessity of rewinding to a particular fan. Before handing over fan to the contractor, testing for winding shall be done in presence of EIC and all such fans shall be stored separately for subsequent repair from the contractor.
7Supply and replacement ofexhaust fan motor suitable for 225/230mm sweep complete including necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
8Supply and replacement ofexhaust fan motor suitable for 300mm sweep complete including necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
9Supply and replacement ofexhaust fan motor suitable for 380/450mm sweep complete including necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
10Supply and replacement ofindustrial wall mounted fan motor suitable for 450/600mm sweep complete including necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
11Opening up ceiling fan, exhaust fans, wall mounting/table fans, air circulator fans (any sweep, size or make) as kept unserviceable in E/M store yard for detection of defect and reassembling after cleaning, greasing and overhauling including replacement of split pins, body/blade screws and testing before depositing in store yard complete all as specified and directed. Note: Other spares necessary to be replaced shall be measured and paid for separately under following items of this schedule.
12Supply and fix in replacement of Capacitor 2.5/3.15 mfd 230 Volts (+) 5 % dry type complete all as specified and directed. Make- TIBCON/ELCAP/"AD/TORCON)
13Supply and fixing PVC capacitor assy two ways with fixing screwsany type all as specified and directed
14Supply and replacement of ball bearing for ceiling fans of any sweep/size/ any make complete all as specified and directed. Size of 6200,6201,6202,6203,6204 & size S-7/S-8 (Make of bearing : Make ABC/SKF/NBC. Note : Ball bearing shall be replaced in the store yard of E/M or in the civil workshop on lathe machine if required and cost thereof shall be included in quoted rates in this item.
15Replacement of gun metal bush for ceiling fans, exhaust fans and cabinsfans of any makes/size complete all as of specified and directed. Note : Bush shall be replaced in the store yard of E/M or in the civil workshop on lathe machine if required and cost thereof shall be included in quoted rate in this item. Note:- Cost of replacement of UNSV Shaft for exhaust fan of capacity 200/300mm sweep shall be included under this item.
16Taking down and refixing of ceiling fan after supply and replacement of rubber reel of ceiling fan complete with ms split clamp two Nos, nuts and bolts complete all as specifiedand directed by Engr-in-charge.Note:-Contractor has to submit the certificateregarding serviceable condition of rubber reel, fan hook, clamp hook and split pin of ceiling fan.
17Supply and replace fan regulator electronic, Piano type, stepped, AC 230 volts suitable for 1200mm/1400mm ceiling fan complete all as specified and directed .
18Supply and replace fan regulator electronic, modular type as per sample, stepped, AC 230 volts suitable for 1200mm/1400mm ceiling fan complete all as specified and directed .
19Replacement of Capacitor 4 mfd 230 Volts (+) 5 % dry type complete suitable for desert cooler all as specified and directed. Make- TIBCON/ELCAP/"AD/TORCON)
20Replacement of ceiling fan blade(multipurpose type) suitable for 1200 mm sweep ceiling fan including nuts, washers etc complete all as specified and directed suitable for any make of fan. (white/Browm colour/as per site requirement).
21Supplyand connecting flexible copper wire 2 core Cableof size 23/0.0076, 0.5 sq mm (white colour)complete all as specified and directed.
22Supply & fixing as in old/damaged body ofExhaust Fan made of steel properly painted with all fixtures make as same of motor andsize upto 300 mm complete all as specified and directed.
23Supply & fixing as in old/damaged body ofExhaust Fan made of steel properly painted with all fixtures make as same of motor andsize upto 380/450 mm complete all as specified and directed.
24Supply & fixing as in old/damaged body ofwall mounted Fan made of steel properly painted with all fixtures make as same of motor andsize upto 450/600 mm all as directed by Engineer-in-Charge.
25Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make andsize 380mm/450mmall as directed by Engineer-in-Charge.
26Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make andsize 300mmall as directed by Engineer-in-Charge.
27S&F in Replacement ofPVC canopy (upper/bottom) for ceiling fan of any make andsize all as directed by Engineer-in-Charge.
28Supply & fixing down rodfor ceiling fans made out of MS pipe 15mm bore medium grade 60 cm long duly threaded, holes drilled and spray painted with synthetic enamel paint all as directed by Engr-in-Charge
29Supply & fixing down rodfor ceiling fans made out of MS pipe 15mm bore medium grade 1.2 m long duly threaded, holes drilled and spray painted with synthetic enamel paint all as directed by Engr-in-Charge
30Spray painting on outside body of the ceiling fan incl blades any size with synthetic enamel paint (white colour)including scrapping existing paint and incl writing MES Number with black paint all as directed by Engr-in-Charge.
31Spray painting on outside body of the exhaustfan incl blades any size with synthetic enamel paint(smoke gray colour) including scrapping existing paint and incl writing MES Number with black paint all as directed.
32Supply and fix ceiling fan box round cover plate size 6 inch complete all as specified and directed by Engr-in-chrge.
33M & L for two coat of super enamelled paint over a coat ofred oxide primerfor Desert cooler of any size/ make and matching the same on the exterior colour by metal paste/putty complete all as specified and directed.
34Dismantling of desert cooler motor,(any make and type,taking out rotor removing all coils(burnt and alive)rewinding all the coils with suitable size super enamled copper wire(ISI marked) including all packing materials,insulating materials,varnishing greasing oils,reassembling,split pins, body blade screw and testing on full speed as per the direction of EIC complete all as specified and directed .Note: Cost of Replacement of UNSV gun metal bush and shaft for desert cooler shall be included under this item
35Supply and fixing in replacement submersible PVC body Tulu pump suitable for desert cooler of any size. Make- KHAITAN/COOL HOME/CG
36Supply and fixing in replacement wood wool padding for desert coolers on all three sides ( for any size and type of cooler) all as directed.
37Supply and fixing flexible PVC transparent 15mm bore pipe set comprising one pipe from pump to PVC junction and 3 Nos short pieces of pipe from junction to shutterall as specified and directed.
38Supply and replacement offan motor 1/10HP capacity suitable for desert cooler completeincluding necessary fitting & connection. (Make:Khaitan/Cool home/Crompton Greaves
39Supply and replacement of Desert Cooler body duly spray painted made out of 22 gauge MS sheet complete with front grill side shutters, control switch piano type 5 Amp speed regulator including lamp, wiring with suitable copper cable complete all as specified and directed.
40Supply and fixing in replacement of PVC front grill (Jali) of suitable size of desert cooler all as specified and directed.
41Supply and fix as in replacement flexible copperconductor cable 3 core, PVC insulated of size70/.0076 and connected electrically to any electric devices/ofanycapacity sizetype & make etc complete all as specified and directed.Make:KEI,Plaza,Kalinga,Havells
42Supply & replacement of regulator knob type switch, 3 step control of speed of Desert cooler motor 230 volts, 50 Hz all as specified and directed.
43S & Ffan (PVC or metal) blade of suitable size for desert cooler complete all as specified and directed.
44S & F Top Plug3 Pin 5 Amps 230 Volts Make: Anchor/Plaza/Kalinga/Polycab
45S & F metallic frame with set of 4 legs as per model suitable for fixing/mounting fan motor of desert cooler with nuts, bolts, rubber etc., complete all as specified and directed.
46S&F in replacement of PVC water distributor and elbow for desert cooler ( for any type and size of desert cooler) all as directed and specified
47Supply and replacement of PTMT Ball Valve suitable for 15 mm bore pipe complete suitable for desert coolercomplete all as directed.
48Supply and fix fresh air fan (suitable for bathroom/toilets)AC single phase 230/240 volt made of sturdy Engineering plastic complete with louvers shutter, 50 Hz, RPM 1200, Copper winding of sweep 225/230 mm,electrically connecting with twisted three core PVC insulted unsheathedflexible cord of 0.75 Sqmm copper conductor from ceiling rose to PVC Exhaust fan complete all as specified and directedby Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy