Tender For Provision Of 01 Lpg Shed 01 Conference Hall 01 Attached Bathroom And Additional/Alternator To Bldg No P 09 And P 10 At Rangiya, rangia-Assam

Military Engineer Services-MES has published Tender For Provision Of 01 Lpg Shed 01 Conference Hall 01 Attached Bathroom And Additional/Alternator To Bldg No P 09 And P 10 At Rangiya. Submission Date for this Tender is 09-03-2024. Mobile Generator Tenders in rangia Assam. Bidders can get complete Tender details and download the document.




Tender Notice

42427602
Corrigendum : Tender For Provision Of 01 Lpg Shed 01 Conference Hall 01 Attached Bathroom And Additional/Alternator To Bldg No P 09 And P 10 At Rangiya
Open Tender
Indian
Assam
rangia
09-03-2024

Tender Details

Tender For Provision Of 01 Lpg Shed 01 Conference Hall 01 Attached Bathroom And Additional / Alternator To Bldg No P 09 And P 10 At Rangiya

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 40700.0 /-
Tender Value
INR 20.31 Lakhs /-

BOQ Items

Name of Work: PROVN OF 01 LPG SHED, 01 CONFERENCE HALL, 01 ATTACHED BATHROOM AND ADDN/ ALTRN TO BLDG NO P-09 & P-10 AT RANGIA MIL STN UNDER GE RANGIA
Sl. No. Item Description
1Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed by Engineer-in-charge.
2Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-charge.
3M&L for Surface dressing n exc 15 cm deep and getting out in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
4M&L for Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
5M&L for Excavation in post holes (or similar holes) each n.exc 0.5cum in soft/loose soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering and removing of surplus soilto a distance n.exc 50 meters and making good surface, complete all as per specified and as directed by Engineer-in-charge.
6M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
7M&L for Returning,filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
8M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
9M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge.
10M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation or Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge.NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
11M&L for PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundations, fillings and mass concrete complete all as per specified and as directed by Engineer-in-charge.
12M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
13M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
14M&L for Reinforced Cement Concrete, M-25 (Design Mix) (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajjas, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
15M&L for precast reinforced cement concrete 1:2:4, type-B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes, etc.) shelves and similar articles with plain faces and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge. NOTE : Reinforcement will be measured and paid separately under relevant Item.
16M&L for Providing precast cement concrete louvres and jallies, 40mm thick (measured solid), including all mouldings but excluding frame of Type B-0, 1:2:4 (12.5mm graded aggregate) set in cement morter 1:4, complete all as specified and as directed by Engineer-in-charge.
17M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
18M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
19M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, chajjas, etc. also splays between floors and beams, etc., rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
20S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
21S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
22S&F of Mild Steel work in tubular trusses/ posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge.
23S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge.
24S&F of 1.25 mm thick laths Steel rolling shutters, without ball bearing, including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, push pull or manual type with and including Mild steel 4-lever safety lock suitable for rolling shutter, size 100 mm, complete all as specified and as directed by Engineer-in-charge.
25S&F of 4.0mm dia GI Chain Link Fencing of 100x100mm Mesh,including provission of binding wire, complete all as specified and as directed by Engineer-in-charge.NOTE:Cost of Mild Steel Binding Wire shall deem to be included in the quoted Unit Rate.
26M&L for second class hard wood plain fillets in square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc. 6sqcm but not exc.13sqcm, complete all as specified and as directed by Engineer-in-charge.
27M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius inhalf brick thick walls built and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
28M&L for Brickwork with sub-class "B" bricks in one brick thick honey comb walling, built in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
29M&L for Brickwork with Fly ash bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
30M&L for loose filling with broken brick aggregates of gauge 80 to 150 mm in soakage pits, soakage wells, sunken floor, etc., complete all as per specified and as directed by Engineer-in-charge.
31M&L for Rendering 10mm thick in cement morter 1:6 on fair faces of brick work or concrete surfaces/ one side of lathing, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
32M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 on other than fair faces Brick Walls/Concrete Surfaces/ other side of lathing, mixed with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed byEngineer-in-charge. NOTE: WPC shall be Measured and Paid as ‘Supply only’ under relevant Item.
33Supply only Integral waterproofing compound, complete all as specified and as directed by Engineer-in-charge.
34M&L for providing 40mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete (1:2:4), type B-0 (12.5mm gradded stone aggregates), complete all as per specified and as directed by Engineer-in-charge.
35M&L for providing polythene film, 150 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m, complete all as per specified and as directed by Engineer-in-charge.
36M&L for providing 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
37All as per Item No. 36 here-in-above, but for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) , complete all as per specified and as directed by Engineer-in-charge.
38M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair, complete all as per specified and as directed by Engineer-in-charge.
39M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
40All as per Item No. 39 here-in-above, but area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, complete all as per specified and as directed by Engineer-in-charge.
41M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in vertical surface (like skirting, dado, etc.), over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
42M&L for providing Glazed ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 300x 450x 7 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
43M&L for Forming Construction (Dummy) joints 30mm deep x 10mm wide filled with sealing compound Grade "A", complete all as specified and as directed by Engineer-in-charge.
44M&L for Machine cut kota stone slab flooring 20-22mm thick over 20mm thick cement screed base 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed by Engineer-in-charge.
45M&L for Machine cut kota stone slab in riser of steps, skirting, dado and pillar 20-22mm thick over 10mm thick cement screed base 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and as directed by Engineer-in-charge.
46M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as per specified and as directed by Engineer-in-charge.
47S&F of 12mm thick frosted type toughened glass door, each shutter mounted on Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty with and including200mm long Stainless steel handles 2 Nos in each door, 1 No stainless steel 6-lever Mortice lock, vertical type, size 100 mm, anodised aluminum snap beading screws etc., complete all as specified and as directed by Engineer-in-charge.
48S&F of Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc., complete all as specified and as directed by Engineer-in-charge.
49S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge.
50S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement; complete all as specified and as directed by Engineer-in-charge.
51S&F of Steel ventilator with top hung shutter including hinges, steel handle, peg stay, glazing bars, complete all as specified and as directed by Engineer-in-charge.
52S&F of 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
53S&F of 6mm thick Sheet glass, ordinary quality and glazing with aluminium snap beading, rubber gasket in square exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
54M&L for providing in patches not exc. 0.50Sqm GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
55S&F of 100 mm long Butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed by Engineer-in-charge.
56S&F of 150 mm long Extruded aluminium alloy handles, cast type, anodised, complete all as specified and as directed by Engineer-in-charge.
57S&F of 150 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
58S&F of exposed powder coated GI snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with suspended hangers of 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with and including Supply & fixing/ laying/ inserting of pre-painted (white) 4mm thick designer classic E-boards (595x595 mm) to GI frame work, complete all as specified and as directed by Engineer-in-charge.
59S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
60S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
61M&L for preparing newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge.
62M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 1.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
63M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant primer, complete all as specified and as directed by Engineer-in-charge.
64M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat ofred oxide primer, complete all as specified and as directed by Engineer-in-charge.
65M&L for preparation of new or previously un-treated wooden Surfaces of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat ofpink primer, complete all as specified and as directed by Engineer-in-charge.
66S&F of bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed by Engineer-in-charge.
67S&F of 15mm dia galvanised steel tubes, "medium grade", with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
68S&F of 20mm dia galvanised steel tubes, "medium grade", with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
69S&F of Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and as directed by Engineer-in-charge.
70S&F of Wash down water closet (Pedestal pattern) pan and S/P trap of 540x375x415mm with and including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or anodised aluminium hinging device including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc., complete all as specified and as directed by Engineer-in-charge.
71S&F of Vitreous China wash basin, white, with brackets, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand, fixing of 15mm dia 450mm long PVC connection pipe and 32mm dia 900mm long PVC Flexible waste pipe with and including 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.; complete all as specified and as directed by Engineer-in-charge.
72S&F of 10 litre capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and PVC flush pipe of 32 mm dia, with and including making necessary connections, complete all as specified and as directed by Engineer-in-charge.
73S&F of 15 mm dia fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge.
74S&F of 15 mm dia fancy type chromium plated Pillar taps, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge.
75S&F of 15 mm dia fancy type, chromium plated Stop valves/ Angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engineer-in-charge.
76S&F for 32mm dia High density poly ethylene pipes (HDPE) of pressure rating 6 kg/ cm2fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
77S&F of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls/ laid in trenches, complete all as specified and as directed by Engineer-in-charge.
78S&F of 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-in-charge.
79S&F of 110mm dia PVC (SWR) vent cowl, complete all as specified and as directed by Engineer-in-charge.
80S&F of PVC connection pipe 15mm dia with PTMT nuts of length 450mm, complete all as specified and as directed by Engineer-in-charge.
81Supply, install and testing of LLDPE septic tank with top cover suitable for 10 Users with and including earthwork in excavation, 150mm thick P.C.C. 1:4:8 (type D-2) for bed, making connections of inlet/ outlet/ Vent pipe, returning filling and removing of surplus soil at a distance of not exceeding 50.0m from site, complete all as specified and as directed by Engineer-in-charge.
82M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push,complete all as per specified and as directed by Engineer-in-Charge.
83S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
84S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
85S&F ofSheet Metal Enclosure MCB DB SPN, 2 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge.
86S&F ofSheet Metal Enclosure MCB DB SPN, 4 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoingMCBs of any type, complete all as specified and as directed by Engineer-in-charge.
87S&F of MCB Single Pole & Neutral (SPN), "C" Curve, 32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
88S&F of MCB Single Pole (SP), "C" Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
89S&F of surface and wall mounted LED tube light fitting 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
90S&F of surface and wall mounted LED light fitting mirror type 1x 10W, (2 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
91S&F of energy saving ultra modern environmental friendly sleek LED Bulk headfitting 10 watt, IP65 protection with driver, holders & LED lamp including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
92S&F of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 35/36 watt, 220-240 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
93S&F of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC), including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
94S&F of exhaust fan, sturdy engineering plastic body, AC single Phase, 230V of size 250m sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
95S&F of PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep, complete all as specified and as directed by Engineer-in-charge.
96S&F of 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor of, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 16.0 Sqmm section, complete all as specified and as directed by engineer-in-charge.
97All as per Item No. 96 here-in-above, but for cross-sectional area 16 Sqmm 2 Core, laid in Pipe/ Ducts/Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
98M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade) andchamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:-(i)item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire.
99Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
100S&F of Galvanised Iron Pipe 32mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
101S&F of ceiling fan hook made out of MS Flat Iron of 50x6mm thick with and including 12mm dia round bar bend to required shape and nut-bolt-washer and painting the MS Flat iron/ round bar/ nut-bolt-washer with two coats of synthetic enamel paint, complete all as specified and as directed by Engineer-in-charge.
Disclaimer :