Tender For Additional/Alternator To Omq P-45 At Afs Madh Island Under Ge Af Thane, thane-Maharashtra

Military Engineer Services-MES has published Tender For Additional/Alternator To Omq P-45 At Afs Madh Island Under Ge Af Thane. Submission Date for this Tender is 19-03-2024. Mobile Generator Tenders in thane Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42427427
Corrigendum : Tender For Additional/Alternator To Omq P-45 At Afs Madh Island Under Ge Af Thane
Open Tender
Indian
Maharashtra
thane
19-03-2024

Tender Details

Tender For additional/alternator To Omq P-45 At Afs Madh Island Under Ge Af Thane

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Mar-2024 TENDER DOCUMENT Other 12-03-2024
2 12-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 85000.0 /-
Tender Value
INR 42.50 Lakhs /-

BOQ Items

Name of Work: ADDN/ ALTN TO OMQ P-45 AT AFS MADH ISLAND UNDER GE AF THANE
Sl. No. Item Description
1Removing existing water proofing treatment what so ever exist (except concert padding) and removing debris/ rubbish materials off the site complete all as specified and directed by Engr-in-Charge.
2M&L for roughening surfaces of old concrete floor by picking, sweeping clan and washing down with water to remove dust & brushing neat cement slurry with 3 Kgs of cement per sqm etc all as specified and directed by Engr-in-Charge.
3M&L for Plain cement concrete (PCC) padding in cement concrete (1:2:4) type B0 (using 12.5 mm graded aggregate) finished even and smooth without using extra cement all as specified
4M&L for 15mm screed bed or bedding layer in cement mortar 1:4over RCC Slab horizontal or vertical portion for laying water proofing treatment all as specified & directed by Engr-in-Charge.
5M&Lfor APP modified roof treatment over existing RCC roof with following specification :-(a) Applying bitumen primer @ 0.4 Liters/Sqm with density of 0.87 to 0.89 Kg/Liters at 25 degree C on the prepared dry roof surface. (b) Laying 3 mm thick APP membrane weight not less than 3.50 Kg/Sqm by torch application with minimum 10cm side lap and 15cm end lap. The laying of membrane shall be done through an authorised applicator of manufacturer of APP membranE. (c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm prescribed by manufacturer complete all as specified and directed by Engineer-in-Charge.
6Dismantling water tanks capacity 500 ltr including all fittings all as per specified and directed by engg-in-charge
7S&FRotational moulded polyethylene water storage tanks (cylindrical verticalwith closed top) with500 litre capacity hoisted and fixed in position all as specified in SSR Part I
8Taking up or down 20 mm dia bore steel tubing and connections, including cleaning for re- fixing and removing to store.
9Taking up or down 15 mm dia bore steel tubing and connections, including cleaning for re- fixing and removing to store.
10S&F in repairs GI tubing medium grade including all fittings fixed in floor /walls/ ceilling etc 20mm dia bore.
11S&F in repairs GI tubing medium grade including all fittings fixed in floor /walls / ceilling etc,15mm dia bore.
12S & F20mmBall valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed ( minium weight20mm-210 gmsPTMT fittings shall be approved makes.)
13S&F in repair stop valves cast copper alloy, screwed down, high pressure with butterfly handle, screwed both ends for iron pipe or for unions 15mm bore.
14S&F in repair bib taps fancy type cast copper alloy chromium plated with butterfly handle, screwed down, screwed for iron pipe or for brass ferrule 15mm bore all as specified.
15Dismantling of plain or corrugated steel sheeting any gauge thickness including Nanital or similar pattern roof covering
16Dismantling wrought iron or mild steel work of any description not otherwise provided for
17Excavating in posts holes (or similar holes) in Soft/loose soil each n.exc 0.50 cu.m getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm watering, and removing surplus soil to a distance n.exc 50m and making good surface.
18M&L for providing PCC 1:2:4 type B2 using (40mm graded stone aggregate) in foundation filling and mass concrete.
19S&F Pre-painted galvalume aluminium zinc cozting GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering fixed with self tappping screws as specified.
20S & F Plates( Plain or chequered ) of Fe-410-W (Gde-E-250) Quality -B channels,square cut or notched (ordinary and counter sunk) forming holes, without any attachment.
21M&L for newly untreated Surfaces two coat of synthetic enamel paint over a coat of Red oxide of any description, over 10cm in width or girth,not otherwise described
22S& F Rooled section in MS inJoist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengthsi.e. within 20mm of the length indicated) complete all as specified and directed by Engr-in-Charge.
23Taking down cement plaster on brick/stone or concrete surface including racking out joints, hacking for key, scrubbing down with water to receive plaster, including removing debris/rubbish materials off the site all as specified.
24M&L for rendering 5 mm thick in cm 1:3 on fair faces of concrete as in soffit/ ceilling or slab, chajjas finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
25M&Lfor rendering 15mm thick in cm 1:6 finished with neeru finish as specified on fair faces of brick work /stone or concrete surfaces complete all as specified and directed by Engineer-in-Charge.
26M&L for cement plaster in CM 1:4, 20mm thick in two coats (15+5) with using integral waterproofing compound finished even & smooth without using extra cement ( Note: Integral liquid water proofing compound to be used in per bag of cement shall be as per manufacturers instructions and paid separately under respective items.).
27M&L preparing newly plastered surfaces ,and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer Over 1 mm thick wall care putty on wallscomplete all as specified and directed by Engineer-in-Charge.
28M&L preparing newly plastered surfaces ,and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer Over 1 mm thick wall care putty on ceiling complete all as specified and directed by Engineer-in-Charge.
29Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces all as specified and directed by Engineer-in-Charge.
30M & L for applying two coats of acrylic weather proof exterior emulsion paint all as per manufacturer instrctions to external plastered wall surfaces including preparation of old treated surface to receive the treatment etc all as specified and directed.
31M&L Complete removal of existing treatment on old surface of walls and applying 2 coats of Oil Bound Distemper over a coat of alkali resistent primer.
32M&L for Preparation of old surfaces of ceiling and applying two coats of oil bound distemper.
33Taking down Shutters exc 1 sq. m and n exc 2 sq. m each all as specified and directed by Engr-in-Charge
34S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. All as per item no.08082 but wire gauzed i.e. panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly
35S&F 150mm long Aluminium handles, cast type, anodised all as specified and directed byEngr-in-Charge.
36S&F 100mm long Aluminium handles, cast type, anodised all as specified and directed byEngr-in-Charge.
37S& F 100mm long Butt hinges, extruded alu- minium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 all as specified and directed by Engr-in-Charge.
38S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and directed by Engr-in-Charge.
39S&F 150mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed all as specified and directed by Engr-in-Charge.
40S&F 100mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed all as specified and directed by Engr-in-Charge.
41S&F door sliding bolt aldrop 300 mm long aluminium anodised Make-classic/Shalimar etc equivalent ISI Marked.
42Taking down chowkhats or frames n.exc 1.5 Sqm eachwith shutters (without taking off shutters from the frames)
43S&F IInd class hard woodplain, solid, straight chowkat and frame wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified.
44S&F MS bands, straps, supports of stays, hold fast, wall ties etc and similar articles etc confirming to Fe-410-310m
45M&L for cutting holes in bricks walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar or cement concrete 1:2:4 type B1 as required exc half brick but not exc one brick complete and as directed
46S&F in repairs wash down water closet squatt pattern including connection to trap, and to flushing pipe, anti syphonage pipe etc. complete including making good to floor complete including provn of lime concrete bedding all as specified and directed by Engr-in-Charge.
47S&F in repair PVC (SWR)bendsany radius
48S&F in repair 110mm PVC (SWR) WC connector bent type
49S&F in repair Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
50S&F in repair Cast iron nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
51S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
52Taking down aluminium sliding windows of any description and any size and replacing the wornout, broken wiremesh, aluminium sections, glass, rubber beading, rollers, locks etc as required and fixing back in to the same opening for easy movement of shutters including necessary fittings and fixtures. NOTE :- Items such as i) Wiremesh, ii) Glass, iii) Rubber beeding, iv) Rollers v) Locks, vi) Aluminium sections etc will be paid seprately under respective items as suppy only.
53S&F aluminum powder coated( of approved colour) any track sliding windows with aluminum sections mentioned in catalogue of approved manufacturer including suitable Nylon beading, channel gasket, nylon rollers, star lock with handle with complete fittings including water tightening using silicon compound all around etc complete all as specified and as directed.
54Supply only Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as directed by Engr-in-Charge
55Supply only ordinary sheet glass 4.8mm thick in square exc 0.5sqm in each panes.
56Supply only PVC Star lock for Aluminium windows.
57Supply only Nylon / PVC Rollers for Aluminium Windows.
58Supply only Rubber beeding suitable for aluminium door/window shutters.
59Supply only powder coated of approved colour aluminium grill of 5mm x 8mm bars size of opening 10 ems size mesh RG 103 ( as per Royal grill)
60Demolition of Stone slab and tiles of any description or thickness in floor ,apron etc.
61M&L for machine cut cuddappa stone slab 20 to 25 mm thick as in cills/jambs of window & door openings, set jointed and pointed in neat cement slurry with grey cement slurrymixed with pigment to match the shade of the slab incl rubbing and polishing complete including 15mm thick backing coat in cement mortar 1:4
62Dismenrling floor hearth or wall tilling including cement mortar bedding ( but not backing) all as specified by Engr-in-charge.
63M&L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed 25mm thick in CM 1:6 base laid and joined with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engr-in-Charge.
64M&L for kota stone slab 20-25 mm thick in skirting and joined with gray cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete
65Removal of existing concrete including loose/weak concrete from the concrete structure i.e. beams/columns/deckslab etc upto beyond corroded steel reinforcements to a depth of minimum 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around the corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid featheredging and to provide a square edge complete all as specified and directed by Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
66M&L for Preparation of surface and removal of rust in the loosely bonded concrete of the RCC deckslab, beam / girder and piles shall be chipped out using the mechanical cutter exposing the bars and applying Rust Remover using small brush and allow to react it for 16- 24 hrs. Before applying protective coating,the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all asper manufacturer instructionsand directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
67M&L for applying two coats of Anti-Corrosive Primer two component (epoxy anticorrosive zinc rich coating) on reinforcement steel surfaces uniformely. Coating shall be applied by the brush to the exposed and cleaned rebars with an interval of 45 minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
68M&L preparation of concrete surfaces by removing loose concrete, dust, dirt etc, cleaning the surface properly and applying one liberal coat of epoxy bonding agent ( two component agent) by brush application complete all as per manufacturer instruction and directed by Engr-in- Charge Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
69M&L 50mm thick ( average thickness) modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar on conrete structure. Applying the mortar arround the reinforcement and finishing to bring it in line with existing concrete surface complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
70M&L for holes of dia 16mm and depth 100 mm drilled @ a spacing of 1mtr c/c both ways on the existing structure .The loose cementitious particles are removed using a air blower to clean the holes.Shear Keys of dia 10mm cut from HYSD rebars are anchored into these holes of depth 75mm and bent out to an equal length of 75mm using Resin Anchor Grout complete all as per manufacturer instructions and directed by the Engr-in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
71M&L for Providing & executing injection/pressure grouting in the cracks in the parent concrete by fixing PVC/Aluminium nipples at 150mm to 200mm distance or specified distances as per design and detailed specifications. Pressure grouting using low viscous epoxy grout. Moisture insensitive epoxy resin injection material supplied in 1.5 Litre pack which can grout gaps ranging from 0.25mm to 9mm, having mix density 1060 Kg/m3, compressive strength 60 N/mm2, Tensile Strength 20 N/mm2, Flutural strength 45 N/mm2. Pressure grouting shall be carried out after surface preperations includes fixing nipples and filling cracks with epoxy mortar one day before grouting, injecting low viscous grout mechanically about pressure 3.5-7.0 Kg/Cm2, removing nipple after grouting and sealing with epoxy mortar etc complete as directedby Engr - in - Charge. Payment shall be made on actual grout consumed. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
72M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polimer modified cementitious ,low permeable"free flow "non shrink "self compacting micro concrete shall be grade M70 as per recommended w/c ratio and pouring as per the required thickness complete all as per manufacturer instructions and directed by Engr- in- Charge. Note :- The contractor Quoted rate should includes necessary scaffolding and form work both for new work as well as for protection of existing structure during rehabilitation.
73Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
74M&L for 75 mm Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
75M&L for 75 mm thick PCC 1:4:8 type C-2 (using 40mm graded aggregate) finishing the concrete surface even and fair all as directed as in sub base etc.
76M&L for 75 mm thick PCC 1:2:4 type B-2 (using 40mm graded aggregate) finishing the concrete surface even and fair all as directed as in sub base etc.
77S&F Prelaminated particle board,interior grade,prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with screws to timber frame work
78S & F Continuous (piano) hinges mild steel,bright finish or electrogalvanised
79S&F hasp & staple,ditto but of aluminium anodised
80S&F in repairs aluminium powder coated decorative draphery rod 20 to 25mm dia.
81S&F in repairs aluminium powder coated brackets suitable for decorative draphery rod 20 to 25mm dia.
82dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing),removing serviceable tiles to store and rubbish off the premises
83M&L granite tiles 20mm thick machine cut ,bedded and jointed with grey cement slurry and pointed with white cementwith admixture of pigment to match the shade of granite stone including grinding and polishing complete
84M&L 12mm thick plywood, grade BWP, type I, or surface finish, colour and pattern as approved
85S&F 0.9mm Thick Decorative laminates type I or surface finish, colour and pattern as approved
86S&F Stainless steel cage for modular kitchen of required gauge/ dia suitable for accomodating sliding kitchen cabinets
87S&F Pullouts, telescopic channels blumotion channels, bottom mountedchannels, for Modular Kitchen of approved make of required length suitable for kitchen cabinets.
88Taking down carefully point wiring and removing from site such as (Light,fan socket or power) Complete including fitting and fixtures,fan regulators switch boards,switches,ceiling rose"s lamp holder from existing batten PVCconduit/steel conduit wiring complete excluding light fittings and fans all as specified and making good to the disturbed surfaces to match with existing ,complete all as specified and as directed
89M & Lfor concealed conduit point wiring complete for light/ fan on independent /combine boardwith cable 1.5 sqmm (Nominal area) FRLSPVC insulated multistranded unsheathed copper conductor,drawn in and includingPVC Concealed conduitpipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , aftercutting in wall chasing for conduits and sinking"s for modular metal flush boxes suitable lengthandthickness for mounting, switches, sockets,fan regulatorwith modular cover plate with frame and making the gooddisturbed surfaces of wallin CM 1:3 with white wash or existing colour including provision ofcontinuousearth continuity conductoralong with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switchand connected to commonearth dolly, complete all as specified anddireced.
90All as per Srl item No -89.00 here in before but for one switch socket combination5/6 amp on independent board complete all as specified and directed
91All as per Srl item No -89.00 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed
92All as per Srl item No -89.00 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed .
93All as per Srl item No -89.00 here in before but for one light point controlled by two 2 ways switches complete all as specified and directed .
94All as per Srl item No -89.00 here in before but for call bell point complete all as specified and directed .
95S & F in replacement modular switch5/6 Amps single pole one way,one module including modular cover plate with frame and metal flush box complete all as specified and directed
96S & F in replacement modular switch socket combination 5 pin, type 5/6 Amps5 in 1flush type including modular cover plate and metal flush box with frame complete all as specified and directed
97S & F in replacement modular switch socket combination 6 Pin, 5/16 Amps flush type including modular cover plate with frame and metal flush boxcomplete all as specified and directed.
98S & F modular switch5/6 Amps single pole two ways complete all as specified and directed.
99S & F modular socket outlet 5 pin 5 Amps flush type complete all as specified and directed.
100Supply and fix in replacement industrial socket metal clad plug and socket with MCBs single pole 20 Amp complteall as specified and directed.
101S&F modular bell push 5 Amp complete all as specified and directed
102S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed
103S&F Buzzer AC 230 single poleVolt ding dong type complete all as specified and directed.
104S & F ceiling rose surface bakelitethree terminals complete all as specified and directed
105Taking down carefully existing serviceable LED Tubelight/ bulkhead/ security light/ recess mount fitting of any sizeand refixingthe same to respective location after carrying outcleaning all the components of fittings, including replacement of nuts, bolts and connection withflexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connectorcomplete all as specified and directed
106S & F in replacement LED Tubelight fitting with polycarbonate housing andintegrated electronic driver,20 watt having input voltage AC90-300V, 50 Hz , 6500K, surge protection min 4 KVA and all other accessories including connection with flexiblecable copper conductortwin coreof size 23/.2 mm upto ceiling rose/connector complete all as specified and directed.
107Supply and fixing LED building security light fitting 25 Watt 230 V, surge protection 10 KVA, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.& Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed.
108S&Fin replacement decorative wall light,brushed nickle finish fixture with OPAL glass diffuser including 9 watt LED B22 base complete all as specified and directed
109S & F in replacement LED Bedside Light (White,3000k) 3 Watt, with flexible arm suitable for reading complete all as specified and directedMake : Philips 48042 or equivalent make in Havells,Bajaj
110S & Fin replacement LED Water tight bulk head fitting 10 W,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LEDall as specified and directed.
111S & F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. all as specified.
112S & F in replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed
113S&F LED lamp 9W for angle holder complete all as specified and directed
114S & F in replacement of sub-main wiring with PVC insulated and un-sheathed4 x 6.00 sqmm (Nominal Area) FRLS stranded copper conductor drawn in and including PVC"medium quality" concealed conduit as per size required including 2 x 6Sqmm (Nominal area) copper cable as earth contiunity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and coversincluding necessary connections, PVCflexible pipes are used in panel board while connecting the cablecomplete all as specified and directed (Note : PVC cable and PVC conduit shall be ISI marked) Note :- Four length of 6 Sqmm cable and two length of 6 Sqmm earth cable along with PVC conduit will be measured as one running length
115S&F in replacement sub main two single core PVC copper conductor unsheathed wiremulti stranded 4 sqmm FRLS including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc andincluding 4.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia concealed PVC conduit, medium grade, ISI marked complete all as specified and directed Note :- Two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cable along with PVC conduit will be measured as one running length
116S & F in replacement sheet metal enclosure for double door BDs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 6 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed complete all as specified and directed.
117S & Fin replacement MCB ‘B’ series type suitable for 415 volts, 10 KA, AC supply40 to 100 Amps,triple pole and neutral (TPN) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed .
118S & Fin replacementMCB ‘B’ series type suitable for 240 volts,10 KA,AC supply6 to 32 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed .
119M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earth strip 32 x 6 mm thick fixed by means of bolts, nuts and washers ofgalvanised iron or steel and thimbles and other end of the earth strips connected to earthing test point and protected by galvanised iron pipe light grade 40mm diaand watering pipe 20mm dia GI medium grade withplug socket and above ground level including earthwork, PCC chamber in PCC (1:2:4) type B-1 using 20mm stone aggregate, cast iron cover, wire mesh etcall as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009complete and all as specified and direcrted Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) Cost of earth lead GI strip connecting upto pump,Gen set,LT panel and DBs earth connection or earthing test point is included in this item (7.50RM). (iii)GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
120M&L for Disconnectingelectric connection and taking down carefully serviceable ceiling fans and Geyser and keep in safe custudy. After the building repair work or as directed refixing /hanging the ceiling fan and geyser including electric connection with and including new flexible sheathed copper wire 3 core from ceiling rose/connector to fan connector, including in replacement new nut bolts, rubber reel, capacitor 2.5mfd, machine screws and split pins etc including painting the ceiling fan complete body with blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint in colour as directed complete all as specified
121S&F Heavy duty metal body exahust fan of 450mmsweep ,240 volt,copper winding, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVCsheathed copper conductorflexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colour etc. complete all as specified and directed
122S&F exhaust fan made of sturdy engineering plastic of 250mmsweep ,240 volt, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVCsheathed copper conductorflexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1 :4) white washing matching with existing colourcomplete all as specified and directed
123S&F ceiling fans AC single phase 230/240 V of size 1200 mm sweepwithout regulator having Min air delivery 210 CFM with service value 6.00 BEE5 star rated with brushless direct current motor (BLDC) complete with electrical connection providing three core round flexible copper conducter cable of suitable sizecomplete all as specified and directed MAKE: Orient electric 1200mm hector 500. Havells effeciencia neo 1200mm, Cromption Energin HS.
124S&F storage type water heater (Geyser) electrical operated 230/240 Volts25 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, fusible plug,top plug 15Amp ,heating element upto 2 KW rate pressure 6 bar etc. required for proper functionality & including electric/earth connections and carrying out grounting & complete installations with mounting bolts,nuts including testing after installationcomplete all as specified and directed
125S&F storage type water heater (Geyser) electrical operated 230/240 Volts50 ltr capacity, BEE 5 star rated complete with all safety equipment and accessories such as safety valve, thermostat, fusible plug,top plug 15Amp ,heating element upto 3.5KW rate pressure 8 bar etc. required for proper functionality & including electric/earth connections and carrying out grounting & complete installations with mounting bolts,nuts including testing after installationcomplete all as specified and directed
126Supply and fix PVC connection High Density Pipe 15mm sizes with PTMT nuts of lengths 600mm suitable for Cold and Hot water complete all as specified and directed
127Dismantling and Taking downL.T. under ground armored PVC/XLPE insulated and PVC/XLPE sheeted heavy duty 1100 Volts grade under ground cable ofany size complete all as specified and directed.
128Taking out serviceable unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mmduring excation of trenches and relaying after cable laying in trenches all asspecified and directed
129Excavation in trenches not exceeding 1.5 m wide and not exe 1.5 M in depth and getting out in hard/dense soil complete all as specified and directed .
130Returning filling in including spreading leveling, watering and well ramming in layers not exe 25 cm each layer complete all as specified and directed.
131Removing excavated material to a distance not exe 50 M and depositing where directed not exceeding 1.50 M above the starting point complete all as specified and directed.
132Supply and spreading in trenches cleardry sand for cable protection and punning down gently 10 cm below the cable and 15 cm above the cable all as specified. Note :- Punning thickness only measured.
133Supply and laying unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 ISI marked flat size 250x150x40 mm laid in trenches as specified and as directed.
134M&L for cutting existing road/hard standing not exc 50x60 cm in wide & depth getting out excavated material for laying GI tube , for passing through LT cable, returning filling & well rammaing wateringfinish suraface 10 cm from top using PCC 1:1.5:3; including removal of surplus soil complete all as specified and directed
135Supply and lay jointing and testing and commissioning in replacement of 35 Sqmm x 3.5 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed
136Supply and fix 3 pin telephone socket RJ 11 with metal flush box having holes for 20 mm conduit entry for telephone connection all as specified and directed
137S & F Rigid non-metallic concealed PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
138Supply and lay GI pipe 50 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc complete all as specified and directed
139Supply and fixing LT Cubical Type meter box pannel wheather proof , water proof and made of MS sheet of 2 mm thick CRCA sheet duly powder coated siemens gray shade campartments/ partition suitable to accomadate inside for 04 nos energy meter threephase 4 wire 415 V AC,fixing them with four single core PVC copper conductor unsheathed wire multistranded 6 sqmm including one MCB TPN 40 Ampwithconnected acessories withglass window at front to visualise meter reading without opening of doors, with suitable arrangment of fixing on ground/ on wall with supporting legs properly fixed/tightened to ground and with proper spacing including provision of rubber beading and mild steel cable glands and lugs,provision of air fins for ventilation, complete including all connections incoming / out going, including taking down old panel board any type with fittings and making good disturbed surfaces and matched with existing colour complete all as spdand directed with provn of earthing Copper bus bar and lockable arrangement over main door complete all as specifiedandcomprising of the following items :- (a) MCCB TPN 100A, ISI Marked 415V 50HZ with minimum breaking capacity 16KA with fixed thermal magnetic range-01 Nos (incoming). (b) MCB 40 to 63 Amp ‘B’ Curve Tripple pole neutral -04 Nos (outgoing) (c) Voltmeter 0-500 volts, digital type with selector switch.-01 No. (d) Amp Meter 0-100 Amp Digital type with selector switch.-01 No. (e) Set of three phase indicating lamps-01 Set.
140Taking down old serviceable electronic/electric meter single phase, noting down meter reading and depositing them to MES store complete all as specified and directed
141Supply and fix electronic meters temper proof LCD display with polycarbonate cover, Three phase 415 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time,current reading, load, PF, voltage and KWH complete all as specified and directed
142M&L for steel water tubing medium grade of size 25 mm bore with all fittings laid in trenches or fixed to wall or floor.complete all as specified and directed
143M& L Cutting existing steel tubing for alterations or additions 40m or 50 mm size, Add if necessarily done in position without taking down.
144S & F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed