Rural Water Supply And Sanitation Division has published Supplying Of All Materials, Labour, T&P For Erection , Installation, Testing & Commissioning Of 11 / 0.4Kv 25Kva Dp Mounted S / S = 1 No. ( Handed Over To Tpsodl ) With Brick Boundary Wall, Construction Of 11Kv Line With3x35+1X25mm2 1. Submission Date for this Tender is 28-02-2024. Overhead Line Tenders in buguda Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supplying of all materials, labour, T&P for Erection, Installation, Testing, Commissioning of 11/0.4KV 25KVA DP Mounted S/S = 1 No. ( Handed Over To TPSODL) with brick boundary wall including Stock, Storage & Insurance,Transporation (as per REC Standard) and as per requirement of TPSODL |
2 | 300 KG, 9 mtr long, PSC pole. |
3 | GI Base Plate. |
4 | Pressure Channel GI (100X50x6) mm.(9.20Kg/mtr) x 2.80 mtr.each x 2 Nos |
5 | AB Switch & HG Fuse Mounting Channel G.I.(75x40X6)mm 2.8 Mtr long 4Nos (6.8 Kg./Mtr.) |
6 | Transformer Mounting Channel GI 100x50X6mm (9.20Kg/mtr.) x 2.80 mtr. each x 2 Nos |
7 | Transformer Belting angle GI (50X50X6)mm 7mtr (4.5 Kg./Mtr.) |
8 | LT distribution box Mounting Angle GI (50x50x6)mm (4.5 Kg./Mtr.) |
9 | 200 Amp 3 pole AB Switch |
10 | 200 Amp 3 pole HG Fuse |
11 | LA ( 9KV,10KA Class) |
12 | Birdproof Cap for 9KV LA |
13 | 11 KV Pin Insulator POLYMER |
14 | Disc Insulator (T & C) 45 KN POLYMER |
15 | HW Fitting (T&C) 45KN |
16 | HT stay set complete |
17 | HT stay Wire (7/10 SWG) |
18 | HT Stay Insulator |
19 | HT Stay clamp ( 1.9Kg/Pair) |
20 | Pipe Earthing Device 40mm dia medium gauge 3mtr long |
21 | 25X6 mm GI Flat (for others) |
22 | 25X4 mm GI Flat (for Lightening Arrester) |
23 | LT distribution box Including Kit Kat fuse |
24 | 25KVA11/0.4KV (AL) transformer BIS Energy Level-II |
25 | Earthing Device coil type (GI) |
26 | G.I Nuts.,Bolts & Washer. |
27 | 55 mmsq AAA conductor for jumpering |
28 | 50 mm23 & 1/2 coreLT PVC cable |
29 | Danger Board |
30 | GI Clamp for danger board GI flat (25x3 mm @ 0.60kg/mtr) 510mm length (0.306kg/piece) |
31 | GI 2Ply 2.5mm dia Barbed wire for antyclimbing Device |
32 | GI Back Clamp for anticlimbing devices 25x3 mm Flat (0.6kg/mtrs) Flat of 510 mtrs Length = 4 Nos. (1.22Kg/Pole) |
33 | Sundries (Painting, Clamp, Connector & Jumpering Materials) |
34 | Supplying of all materials, labour, T&P for Construction of 11KV Line with3x35+1x25mm2 11KV XLEP Cable = 0.04Km (3 Span, 1 Spare ckt) using 2 Nos. 9 mtrs. Long PSC Pole including Stock, Storage & Insurance, Transporation (as per REC Standard) and as per requirement of TPSODL |
35 | 300 KG, 9 mtr long, PSC pole. |
36 | Disc Insulator T & C Type 45 KN POLYMER |
37 | HW Fitting (T&C) 45KN |
38 | 11KV Pin Insulator POLYMER |
39 | 100X50x6 mm.GI Channel (9.20Kg/mtr) |
40 | 3x35mm2 11 KV XLPE Cable |
41 | Heat Srinkable Jointing Kit 3 Core 35 mm2 11KV XLEP Cable (out door type) ( Double) |
42 | Lighting Arrester (9KV, 10KA) at XLPE Cable Taping |
43 | BIRD CAP FOR 9KV SURGE ARRESTER |
44 | 75x40x6mm, Channel for LA |
45 | Stringing of 11KV XLPE Cable on overhead with 7/12 SWG G.I Stay Wire & Clamp, Connectors & Strain fittings, Channel Etc.,(DOUBLE) |
46 | G.I. Earthing Electrode 40mm dia medium gauge for LA & XLPE |
47 | GI Flat 25X6 mm |
48 | HT stay set complete |
49 | HT Stay Insulator |
50 | HT Stay clamp ( 1.9Kg/Pair) |
51 | 7/10 SWG GI stay wire |
52 | 8 mtr long, 200 KG, PSC pole for stud |
53 | Stud pole clamp |
54 | Earthing Device coil type (GI) |
55 | PG Clamp for 55 mmsq AAA conductor |
56 | G.I Nuts.,Bolts & Washer. |
57 | GI 2Ply 2.5mm dia Barbed wire for antyclimbing Device |
58 | GI Back Clamp for anticlimbing devices 25x3 mm Flat (0.6kg/mtrs) Flat of 510 mtrs Length = 4 Nos. (1.22Kg/Pole) |
59 | RCCI Base Plate. |
60 | Danger Board |
61 | GI Clamp for danger board GI flat (25x3 mm @ 0.60kg/mtr) 510mm length (0.306kg/piece) |
62 | Saundries |
63 | Supplying of all materials, labour, T&P for Erection, Installation, Testing Construction of LT Line using 3x35+1x25mm2 AB Cable = 0.06Km. (3 Span) & 1 Nos. 8 mtrs. Long PSC Pole including Stock, Storage & Insurance,Transporation (as per REC Standard) and as per requirement of TPSODL |
64 | 8 mtr long, 200 KG, PSC pole. |
65 | AB Cable (3x35+1x35)mm2 |
66 | Insulated piercing connector Type A main 16 to 95 sqmm. To tape 16 to 95 sqmm. |
67 | Nutral Connector Type B Suitable for main 35-70 Sqmm AAAC & Tape - 2.50 to 10Sqmm service cable cover by black weather resistant insulation cover |
68 | Pole Clamp for Eye Hook for (AB Cable) |
69 | Suspension Clamp With I Hook |
70 | Dead End Clamp I Hook |
71 | LT stay set complete |
72 | LT Stay Insulator |
73 | LT Stay clamp |
74 | 7/12 SWG GI stay wire |
75 | Earthing coil type for support |
76 | Base Plate for support |
77 | Danger Board |
78 | GI Clamp for danger board GI flat (25x3 mm @ 0.60kg/mtr) 510mm length (0.306kg/piece) |
79 | GI 2Ply 2.5mm dia Barbed wire for antyclimbing Device |
80 | GI Back Clamp for anticlimbing devices 25x3 mm Flat (0.6kg/mtrs) Flat of 510 mtrs Length = 4 Nos. (1.22Kg/Pole) |
81 | G.I. Nuts, Bolts & Washers |
82 | Saundries |
83 | Supplying of all materials, labour, T&P for Erection, Installation, Testing, Commissioning etc. of 3 phase service connection For 08 KW Loadincluding Stock, Storage & Insurance,Transporation (as per REC Standard) and as per requirement of TPSODL |
84 | 35 mm sq 31/2 Core PVC Cable |
85 | No. 8 SWG 4.06mm dia Wire |
86 | 63 Amp kitkat fuse |
87 | G.I. Service Conecton Bracket |
88 | Sundries. |
89 | Supplying all materials, labour, T&P for construction of Civil Works. |
90 | Cement concreting for Stud / Stay Anchor plat C.C. foundation1:2:4 sizeby using 20mm size hard granite metal = (0.50Mx0.50Mtrx0.80M) = 0.2cum @ 6177.92 = Rs.1235.58. |
91 | Padding & Concreteing for 8mtr/9mtr long PSC pole C.C. 1:1.5:3 with dimention (0.50Mx0.50Mtrx1.50M) = 0.375 Cum @ Rs 6400.00 = Rs.2400.00 & Coupling C.C. 1:1.5:3 with dimention (0.50Mx0.50Mtrx0.45M) = 0.1125 Cum @ Rs 6400.00 = Rs. 720.00 |
92 | Materials for masonry work for earth pit,Charcoal,Salt Etc.,Earthing Chamber Size (2X2) RCC Slab cover. |
93 | Cost for construction of brick boundary wall |
94 | Supplying all materials, labour, T&P for construction of Fencing Works. |
95 | Grill Gate & locking arrengment |
96 | 4" sand spreading (including supply & labour) |
97 | 4" metal spreading (including supply & labour) |
98 | Supplying of all materials, labour, T&P forInstallation, Fitting, Fixing, Testing, Commissioning etc. of Internal wing toRWSS Pump House including Stock, Storage & Insurance ,Transporation (as per REC Standard) and as per requirement of TPSODL & RWSS. |
99 | Iron frame of size 3-0"x4"-6" made out of flat angle wall mounted for fixing of bus bar, kit-kat, 63A and 32A and control pannel etc., |
100 | Supply & fixing of 38/40 mm dia Gi pipe of required length as per I.E. Rule with perforated holes from bottom to top and upper end threaded and fitted with suitable flange for making connection of earth continuity wire fixed by G.I. nut and bolt and the earth pit have an altimate layer of charcoal and salt & replastering the grooved , cutted walls of pump house with cement mortar after laying the wire from main switch to earth electrode. |
101 | Supply & fixing of 63A, 415V I.C. TPN main switch with fuse unit, 2 nos of 63Amp, 415V kit kat fuse mounted on the iron frame and 2 phase bus bar mounted on the iron frame for distribution of power supply with surface wiring to phase indicator point fixing on suitable size of metalic box with 3mm thick laminated plate with all accessories and connection. |
102 | Supplying and fixing of 32A, 415V, TPN main switch with double fuse unit fixed on MS frame with all accessories etc., complete. |
103 | Supply , fitting, fixing ofsuitable wiringupto single phase motor 2 nos with 63Amp main switch, 32 Amp main switch 2 nos with suitable bus bar and 63Amp. Kit kat unit indicator with provision of light point 3 nos, plug point-1no, fan point-1no, and 2 nos earthing device by providing 16Amp, 230V D.P. main switch fixed on frame with nut and bolt etc., complete |