Tender For Repair Replacement Of Lt Ug Cable Lt Panels And Allied Works At Ina Ezhimala, Kannur-Kerala

Military Engineer Services-MES has published Tender For Repair Replacement Of Lt Ug Cable Lt Panels And Allied Works At Ina Ezhimala. Submission Date for this Tender is 18-03-2024. Electrical Panel Tenders in Kannur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

42398454
Corrigendum : Tender For Repair Replacement Of Lt Ug Cable Lt Panels And Allied Works At Ina Ezhimala
Open Tender
Indian
Kerala
Kannur
18-03-2024

Tender Details

Repair Replacement Of Lt Ug Cable Lt Panels And Allied Works At Ina Ezhimala As Per Boq And Tender Documents

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT OF LT UG CABLE, LT PANELS AND ALLIED WORKS AT INA EZHIMALA
Sl. No. Item Description
1Taking down the unserviceable LT UG cable of size 95 to 300 sqmm 3.5 core/ 04 core including removing electrical connection, keeping side serviceable cable, removing cable protection cover etc complete all as specified and as directed.
2All as per item No.01 above but size up to 70 sqmm complete all as specified and as directed.
3Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard/dense soil complete all as specified and as directed. Note:- a) For all items involving excavation work contractor has to obtain prior approval from station HQ to avoid loss of other co existing utility services, in case of damage to any property he would be liable for its rectification. b)The excavation has to be done manually only.
4Returning and filling in including levelling watering and well ramming into layers not exceeding 25 cm thick in hard/dense soil complete all as specified and as directed.
5Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from startingpoint complete all as specified and as directed.
6Supply and spreading riddled earth for cushioning of the UG cable in trenches complete all as specified and directed by Engr-in-charge. Note:- Punned thickness shall be measured for payment purpose.
7Supply and lay PCC un reinforced cable cover of size 250mmx 150mmx40mm, class LV type I flat for cable protection complete all as specified and as directed.
8Relaying of PCC un reinforced LT cable cover of size 250 mmx 150mmx40mm item obtained from ser no 01 & 02 complete all as specified and directed by Engr in charge.
9Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs, glands XLPE insulated heavy duly galvanised steel strip armoured LT 1100 volt grade with aluminium conductors of size 300 sqmm 3.5 core complete all as specified and directed by Engr-in-charge.
10All as per item No.09 above but size of 150 sqmm 3.5 core complete all as specified and as directed.
11All as per item No.09 above but size of 120 sqmm 3.5 core complete all as specified and as directed.
12All as per item No.09 above but size of 95 sqmm 3.5 core complete all as specified and as directed.
13All as per item No.09 above but size of 70 sqmm 3.5 core complete all as specified and as directed.
14All as per item No.09 above but size of 50 sqmm 3.5 core complete all as specified and as directed.
15All as per item No.09 above but size of 35 sqmm 3.5 core complete all as specified and as directed.
16All as per item No.09 above but size of 25 sqmm 3.5 core complete all as specified and as directed.
17All as per item No.09 above but size of 16 sqmm 4.0 core complete all as specified and as directed.
18All as per item No.09 above but size of 10 sqmm 4.0 core complete all as specified and as directed.
19Relaying cable obtained from taking out in trench/fixing to walls/ pipe/pole with proper saddles, XLPE insulated heavy duly galvanised steel strip armoured LT cable of size upto 70Sqmm 3.5/4 core complete all as specified and as directed.
20Relaying cable obtained from taking out in trench/fixing to walls/ pipe/pole with proper saddles, XLPE insulated heavy duly galvanised steel strip armoured LT cable of size above 70Sqmm 3.5/4 core complete all as specified and as directed.
21Supply and fix in replacement of route indicator for marking of UG cable of any size with cast iron round plate not less than 100 mm dia suitably fitted on iron and embeded with PCC block of size 30 cm x 30 cm x 45 cm complete all as specified and directed by Engr-in-charge.
22Supply and fix in replacement of bus bar chamber 4 way outdoor type of size 90cmx60cmx45cm, made out of 3mm thick MS sheet with 630 Amp rated aluminium busbar (TP&N) with necessary insulators mounted on 25x25x6mm thick angle iron legs fixed in PCC foundation 1:4:8 type D2 complete all as specified and as directed by Engr-in-charge.
23Supply and fix in replacement of bus bar chamber 4 way outdoor type of size 90cmx60cmx45cm, made out of 3mm thick MS sheet with 400 Amp rated aluminium busbar (TP&N) with necessary insulators mounted on 25x25x6mm thick angle iron legs fixed in PCC foundation 1:4:8 type D2 complete all as specified and as directed by Engr-in-charge.
24M&L for cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/pipe, width 0.5 mtr and depth 0.7 mtr all as directed and making good the road/hard using premix bituminous as required at site to match with the existing surface complete all as specified and directed by Engr-in-charge. Note:- Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by Engr-in-charge.
25Supply and fix in replacement of GI tubing light grade 50 mm nominal dia including taking down in trench/road/pole for cable protection complete all as specified and as directed by Engr-in-charge.
26All as per item No.25 above but size of 80 mm nominal dia complete all as specified and as directed by Engr-in-charge.
27M&L for jointing LT Straight through joint kit 1100 volt out door type, of size upto 70 Sqmm 3.5/4 core complete all as specified and as directed by Engr-in-charge.
28M&L for jointing LT straight through joint kit 1100 volt, size up to 120 Sqmm 3.5/4 core complete all as specified and directed by Engr-in-charge.
29M&L for jointing LT straight through joint kit 1100 volt, size above 120 Sqmm 3.5/4 core complete all as specified and directed by Engr-in-charge.
30Supply and fix in replacement of MCB63 Amps TPN 240/415 Volts, "C" curve complete all as specified and directed by Engr-in-charge.
31Supply and fix in replacement of MCB40 Amps TPN 240/415 Volts, "C" curve complete all as specified and directed by Engr-in-charge.
32Supply and fix in replacement of MCCB 100 Amp 16 KA /415volt rating/415volt TPN fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
33Supply and fix in replacement of MCCB 160 Amp 25 KA /415volt rating four pole fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
34Supply and fix in replacement of MCCB 250 Amp 25 KA/415volt rating four pole fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
35Supply and fix in replacement of MCCB 320/350 Amp 25 KA/ 415volt rating four pole fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
36Supply and fix in replacement of MCCB 400Amp 36 KA/415volt rating four pole fixed thermal rating complete all as specified and directed by Engr-in-charge. Note:- MCCB frame size should be as per ground requirement.
37M&L for painting of LT panel board outdoor/indoor of any size using approved shade including welding of minor patches and holes and scrapping out the old paint from existing surface as per site requirement complete all as specified and directed by Engr in charge.
38M&L for cleaning LT panel by removing grass/creepers around the LT panel upto 1m in all side of outdoor panel of any size as per site requirement complete all as specified and directed by Engr in charge.
39Supply and fix in repair/replacement of hinges, sliding door bolt of outdoor/indoor panel and applying grease on hinges and joints for outdoor/ indoor panel of any size as per site requirement complete all as specified and directed by Engr in charge.
40Supply and fix in replacement of Volt meter/Amp meter of any volt complete all as specified and directed by Engr in charge.
41Supply and fix in replacement of surface mounted device LED indicator (Red, green,yellow), low power consumption, surge and low voltage glow protection as per site requirement complete all as specified and directed by Engr in charge.
42Supply and fix in replacement of multifunction meter VAF+PF, 3 phase 5A rating flush mounting complete all as specified and directed by Engr in charge.
Disclaimer :