Military Engineer Services-MES has published Tender For Repairs/Maintenance Of Internal Electrification, Fans, Geysers And Summer Cooling Appliances At Ramnad Underge Tirunelveli(Tender Id:2024_Mes_ 643433_1). Submission Date for this Tender is 13-03-2024. Electrification Work Tenders in Ramanathapuram Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42398086
Tender For Repairs/Maintenance Of Internal Electrification, Fans, Geysers And Summer Cooling Appliances At Ramnad Underge Tirunelveli(Tender Id:2024_Mes_ 643433_1)
Open Tender
Indian
Tamil Nadu
Ramanathapuram
13-03-2024

Tender Details

Repairs / Maintenance Of Internal Electrification, Fans, Geysers And Summer Cooling Appliances At Ramnad Underge Tirunelveli ( Tender Id:2024_Mes_ 643433_1 )

Key Value

Document Fees
INR 500 /-
EMD
INR 67000.0 /-
Tender Value
INR 33.50 Lakhs /-

BOQ Items

Name of Work: REPAIRS/MAINTENANCE OF INTERNAL ELECTRIFICATION, FANS, GEYSERS AND SUMMER COOLING APPLIANCES AT RAMNAD UNDERGE TIRUNELVELI(TENDER ID:2024_MES_ 643433_1)
Sl. No. Item Description
1Providing comprehensive annual maintenance periodical/preventive maintenanceincluding annual maintenance of cooling appliances ( Split type Air Conditioners, Water coolers, Refrigerators and Deep Freezers) as per manufacturer specificationby providing one AC/Refrigeration mechanic including replacement ofcomponents as listed in subsequent items here in after. The maintenance of cooling appliances includes the following:- (a) Cleaning of coil unit with dust blower, lubricate the indoor and outdoor fan motor with oil. (b) Cleaning of air filters, indoor unit grillSupply and fixingilters through air blower. (c) Checking and cleaning the drain connection and air filter periodically, washing of coil with ventiklean solution once in a contract period. (d) Check and replace the refrigerant pipe once in a contract period or as and when required. (e) Check and repair the minor electrical fault in incoming supply. (f) Check and replace the water PVC pipe. (g)Replacementof faulty spares/components (h) Carry out the monthly, quarterly and annual maintenance of all cooling appliances of any make & capacity with job card and making the Cooling Appliances functional(Each Job contains 3 Complaints)
2Supply only the following new items for 1.5 / 2.00 Ton CapacitySplit type AC including testing and commissioning etc complete all as directed.
3Capacitor60 MFD.
4Air filters.
5Condenser fan motor 1.5 HP with blade set .
6Blower fan motor 1.6 HP with blade set.
7Blower with circular leaf.
8Copper condenser coil unit (for A/C)
9Copper cooling coil unit (for A/C)
10Indoor motor capacitor 2.5 MFD.
11Strainer tube (copper)
12Capillary tube (copper)
13Non return valve (For gas top up charging)
14Remote control suitable for Non inverter model Split AC.
15Remote control suitable forinverter model Split AC.
16Electronic components for repairs to PCB
17PCB board suitable for Non inverter model split AC 1.5/2.0 TR
18PCB board suitable for indoor unit of Inverter model split AC 1.5/2.0 TR .
19PCB board suitable for outdoor unit of Inverter model split AC 1.5/2.0 TR .
20Copper pipe of size 1/2" for suction line with foam insulation
21Copper pipe of size 1/4" for discharge line with foam insulation
22Swing Motor for indoor unit
23Outdoor unit stand
24Condenser fan motor blade
25Indoor Motor blower
26Supply and fixPVC insulated unsheathed cables of size 2.5 sqmm 3 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed.
27Supply and fixMetal plug top for AC
28Supply only the new following items for3.00 Ton Capacity Floor standing /Voltas make Tower AC including testing and commissioning etc complete all as directed.
29Air filters.
30Condenser fan motor with blade set .
31Blower fan motorwith blade set.
32Blower with circular leaf.
33Condenser coil unit (for A/C)
34Cooling coil unit (for A/C)
35Indoor motor capacitor 2.5 MFD.
36Strainer tube (copper)
37Capillary tube (copper)
38Non return valve (For gas top up charging)
39Remote control suitable for Non inverter Tower AC.
40PCB board suitable for outdoor unit.
41PCB board suitable for indoor unit.
42Copper pipe of size 5/8" for suction line with foam insulation
43Copper pipe of size 3/8" for discharge line with foam insulation
44Swing Motor for indoor unit
45Outdoor unit stand
46Condenser fan motor blade
47Indoor Motor blower
48Supply and fixPVC insulated unsheathed cables of size 4 sqmm 5 core multi-stranded Copper conductor wire suitable for geysers complete all as specified and as directed.
49Supply and fix Three phase metal plug top
50Supply only the new following items for water cooler 40/80 Litres capacityincluding testing and commissioning etc complete all as directed.
51Relay unit
52PVC float valves , high pressure with polythene float and fly nut screwed to iron pipe or ferrule of bore 15 mm.
53Thermostatassembly
54Water tap suitable for water cooler.
55Starting Capacitor 80-100 MFD
56Running capacitor 36 MFD
57Condenser fan motor 1.6HP with blade set
58Over load protector (OLP)
59Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gas (M-22/F-22) providing NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
60Split type AC 1.5 Ton capacity.
61Split type AC 2.0 Ton capacity.
62Water cooler 40/80 Litres capacity .
63Floor standing/Tower AC3 Ton Capacity.
64Repair to stabilizer of capacity 4 or 5 KVA capacity by removing the old / burnt transformer and replaced with new transformer complete all as directed.
65Repair to stabilizer by removing the old / burnt relay board suitable for Voltage stabilizer of capacity 4 KVA / 5 KVA capacity
66Material and labour for Painting water cooler with super enamel paint of approved colour completeall as specified and directed.
67Supply and fix condensed water PVC flexible pipe of standard quality of suitable size fixing with clamps on wall for split type AC of capacity of 1.5/2.0 Ton complete all as specified and as directed.
68Supply only R22 /R32 /R410 Gas complete all as specified and directed.
69Supply only R134a Gas complete all as specified and directed.
70Dismantling and disconnecting carefully the existing split AC 1.5/2.0 Ton capacity after disconnecting the copper pipe and electrical connection, Cleaning the refrigeration system with CO2 and fixing in a new position including, brazing, testing and commissioning complete all as directed for the following cooling appliances :- NOTE : The wt of refrigerant used for filling/top up shall be measured and paid under respective item.
71Supply only 2 nos of1/2" x 3/8" Foam Heat Insulated Pipe Black for Air Conditioner
72Material and labour for making good surface bysealing the cavity /hole drilled to facilitate tubing, using white cement/POP and cleaning the surface to match with existing surface complete.
73Material only for following items for refrigerators/Deep Freezers 320 Litres capacity including testing and commissioning etc complete all as directed.
74(a) Relay unit.
75(b) Thermostat assembly.
76(c)Condenser coil
77(d) Freezer for double door refrigerator
78Supply only new compressor including pumping out oil, cleaning the refrigeration system with CO2 and charging refrigerant gasproviding NRV for further topping up of gas and re-fixing in the position including complete testing and commissioning all as directed for the following appliances :-
79(a) Refrigerators 310/320 litres capacity.
80(b) Deep Freezers 320 litres capacity.
81Material and labour for Painting with super enamel paint of approved colour for Refrigerator/ water coolercomplete all as specified and directed.
82Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials to store for keeping in safe custody for taking creditand making good disturbed surfaces of walls, floors etc.
83Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing cappingalong with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 1.6 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for :-
84(a) One light point controlled by one switch
85(b) One fan point controlled by one regulator / switch.
86(c)One 3 pin socket outlet 5 amps socket onindependent board
87(d) One 3 pin socket outlet 5 amps socket on Same Board
88(e) One light point controlled by two Nosof two way switches.
89(f) One bell/buzzer point controlled by one push button
90All description as per item No. 23 here-in-before but with 4 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 4 sqmm cable as earthing conductor.
91Supply and fixing in replacement Socket outlet 2 in 1, 3 pin, 5A complete all as specified and as directed.
92Supply and fix in replacement switch piano flush type single pole one way 5 A 240 Volts complete all as specified and as directed
93Supply and fix in replacement switch flush type single pole two way 5 A 240 Volts complete all as specified and as directed.
94Supply and fix in replacement switch Socketcombination 2 in 1,5 Amps Flush type 240 Voltscomplete all as specified and as directed.
95Supply and fix in replacement switch Socketcombination 5 Amps / 16 amps, 5 in 1 flush type 240 Voltscomplete all as specified and as directed.
96Supply and fix in replacementceiling rose3 ways PVC / Polycarbonate, isolated body complete all as specified and as directed.
97Supply and fix in replacement Call bell, ding-dong, suitable for working on 230 volts AC supply, single pole, complete all as specified and as directed.
98Supply and fix in replacementStepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc completeall as specified and as directed.
99Supply and fix in replacement Bell push flush type5 A 240 Volts complete all as specified and as directed.
100S/ F in replacement Modular switch 1 way 5A, 1 Modulecomplete all as specified and as directed.
101S / F in replacement Modular switch 1 way 16A, 1 Modulecomplete all as specified and as directed.
102S/ F in replacement Modular bell push ,5 A, 1 Modulecomplete all as specified and as directed.
103S / F in replacement Modular Socket 5A-2/3 pin combined 2 Module complete all as specified and as directed.
104S / F in replacement Modular Socket5A / 15A - 2 / 3 pin combined 2 Module complete all as specified and as directed.
105S/F in replacement Modular fan Regulator Step type , 2 Module complete all as specified and as directed.
106Supply and fix in replacement Modular switch 5 Amps twoway flush typecomplete all as specified anddirected. complete all as specified anddirected.
107Supply & fix in replacementModular White cover plate with frame, 1 Modulecomplete all as specified anddirected.
108Supply & fix in replacement Modular White cover plate with frame, 2 Module complete all as specified anddirected.
109Supply & fix in replacementModular White cover plate with frame, 3 Module complete all as specified anddirected.
110Supply & fix in replacement Modular White cover plate with frame, 4 Module complete all as specified anddirected.
111Supply & fix in replacement Modular White cover plate with frame, 6 Modulecomplete all as specified anddirected.
112Supply & fix in replacement Modular White cover plate with frame, 8 Modulecomplete all as specified anddirected.
113Supply and fix in replacement Modular metal flush box 1/2module and making good the disturbed surface of wall complete all as specified anddirected.
114Supply and fix in replacement Modular metal flush box 3module and making good the disturbed surface of wall complete all as specified anddirected.
115Supply & fix in replacementModularMetal flush Box 4 Module and making good the disturbed surface of wall complete all as specified anddirected.
116Supply & fixin replacement Modular Metal flush Box 6 Moduleand making good the disturbed surface of wall complete all as specified anddirected.
117Supply & fixin replacement ModularMetal flush Box 8 Module and making good the disturbed surface of wall complete all as specified anddirected.
118Supply and fix PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep including taking down old unserviceable hylum sheet, removing the material for taking credit and making good the disturbed surface of wall complete all as specified anddirected.
119Taking down carefully old unserviceable sub main wiring with aluminum /copper conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc.
120Sub main wiring in replacement with two run single core 4 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 4 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 25 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed. Note: Three runs of 4 Sqmm cable and one run of 25mmconduit / casing capping will be measured as one unit length.
121Sub main wiring with two run single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed. Note: Three runs of 6 Sqmm cable and one run of 32mmconduit / casing capping will be measured as one unit length.
122Sub main wiring with four runs single core 4sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and two runs of 4 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit, 25mm dia/PVC casing capping 32 mmand conduit accessories concealed/surface of wall/roof/ceiling etc complete all as specified and directed. Note: Six runs of 4sqmm cable and one run of 25mm dia conduit/casing capping shall be measured as one unit length.
123Sub main wiring with four runs single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of6 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 32 mm including conduit accessories all as specified and directed. Note: Five runs of 6 Sqmm cable and one run of 32 mm conduit / casing capping will be measured as one unit length.
124Supply and fix in replacement Sheet metal enclosures with socket plug top and MCB SPN 20A, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC )complete all as specified and directed.
125Supply and fix in replacement sheet metal enclosure powder coated double doorfor Distribution Board, SPN 4 way DB,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections,complete all as specified and as directed.
126Supply and fix in replacement sheet metal enclosure powder coated double doorfor Distribution Board, SPN 8 way DBwith 200 A bus bar ,240 V with detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, complete all as specified and as directed.
127Supply and fix in replacement sheet metal enclosure powder coated double doorfor Distribution Board, SPN 12 way DBwith 200 A bus bar ,240 V withdetachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections,complete all as specified and as directed.
128Supply and fix in replacement sheet metal enclosure powder coated double door forDistribution Board,TPN 4 wayDB ,415 V with Detachable Gland Plate, Box Insertion Marks •,Circuit Identification Label •,Neutral Link ,Earth Link , Tin Plated Copper Bus Barincluding , Disconnecting electric connections, completeall as specified and as directed.
129Supply and fix in replacement sheet metal enclosure powder coated double door for Distribution Board,TPN 8 wayDB ,415 V with Detachable Gland Plate, Box Insertion Marks •,Circuit Identification Label •,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, completeall as specified and as directed.
130Supply and fix in replacement sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB with IP 43 - IK 09 including disconnecting electric connections,complete all as specified and as directed.
131Supply and fix in replacementMCB SP 5 A to 32 A, B curve, 10 kA including , Disconnecting electric connections,completeall as specified and as directed.
132Supply and fix in replacementMCB SP 40 Amps , B curve 10 kA including , Disconnecting electric connections, completeall as specified and as directed.
133Supply and fix in replacementMCB SPN 32 Amps, C curve 10 kAincluding , Disconnecting electric connections, completeall as specified and as directed.
134Supply and fix in replacementMCB SPN40 A- 63Amps, C curve 10 kA including , Disconnecting electric connections, completeall as specified and as directed.
135Supply and fixin replacement MCB TP25A - 63 A, C curve 10 kA including , Disconnecting electric connections, completeall as specified and as directed.
136Supply and fix in replacementMCB TPN 16 A- 32 Amps, C curve 10 kAincluding , Disconnecting electric connections, completeall as specified and as directed.
137Supply and fixin replacement MCB TPN40A- 100 A, C curve 10 kA including , Disconnecting electric connections,completeall as specified and as directed.
138Material and labour for earthing complete with galvanised steel earth plate electrode60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 32x6mm GI strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip andetc..including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicableincluding taking down old unserviceable earthing complete for taking into creditall as specified and as directed by the Engineer-in-ChargeNote:-(i) The rates quoted is inclusive of32x6mm GI strip earthconductor upto a length of 7.5m from the earth pit.
139Supply and lay earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth stripof size 32 X 6mm including taking down old unserviceable earth strip complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge
140Material and labour for earthing complete with galvanised steel earth plate electrode60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised steel earth wire 4mm diaas earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 connected to earthing test point, including 20 mm GI pipe (Medium grade) for watering and 40 mm GI pipe (Medium grade) for protection of earth strip andetc..including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wire mesh ,funnel, lugs and charcoal, salt etc all as applicable including taking down old unserviceable earthing complete for taking into credit complete all as specified and as directed by the Engineer-in-Charge complete all as specified and as directed by the Engineer-in-Charge Note:-(i) The rates quoted is inclusive of32x6mm GI strip earthconductor upto a length of 7.5m from the earth pit.
141Supply and lay earth continuity conductor or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth wire 4mm dia including taking down old unserviceable GI earth wirecomplete all as specified and as directed.
142Supply and fix in replacement Lightning Protection Single point air termination aluminum rod 12mm dia 300mm long with base plate complete all as specified and as directed by the Engineer-in-Charge .
143Supply and fix in replacement Test point terminal box made out of Gun metal or Phosphorous bronze of size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex head screwscomplete all as specified and as directed by the Engineer-in-Charge .
144Supply and fix in replacement Aluminium strip of 25x 3.15mm fixed with screws/ clamps / insulators for roof conductors and down conductors above ground level completeall as specified and as directed by the Engineer-in-Charge.
145Supply and fix in replacement MCCB4 pole 415 volts, 63 - 100 Amps, with rupturing capacity 16 KA complete all as specified and as directed including taking down old unserviceable MCCB complete all as specified and as directed by the Engineer-in-Charge .
146Supply and fix in replacementMCCBfour pole 415 volts 50 Hz , 125 amps, with rupturing capacity 16 KA complete all as specified and as directed complete all as specified and as directed by the Engineer-in-Charge .
147Material and labour for Painting the DB Boxes as required at site after scraping out completely the old paint with one coat of red oxide primer and two coats of synthetic enamel paint including carrying out minor welding works if required as directed by the Engineer in charge NOTE:Colour of paint shall be decided by the Engineer-in-charge.
148Writing letters (Block. Roman, Italic or Indian) with thick paint ,stand out boldly and solidly without showing signs of brush marks, or by Stickering, upto 10 cm height and painting with contrasting colour in the background of letter complete as directed.NOTE:Colour of paint/ Stickering shall be decided by the Engg-in-charge.
149Demolition, Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
150Material and labour for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
151Supply and fixing in replacement of ceiling fans complete with blades, down rods, electronicregulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
152Supply and fixin replacement ofexhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and as directed.
153Supply and fixin replacement ofexhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and as directed.
154Supply and fixin replacement ofexhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed.
155Labour Charges for Taking down fan, sealing cable end, dismantling blades and removing fan and blades complete all as specified and as directed.
156Labour Charges forHanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
157Labour Charges forFixing only exhaust fanand connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and as directed.
158Material and labourfor Bearing Heavy Duty double ball bearings/bush bearing set (02 nos) with tolerance, Hardened Carbon Steel Balls with protective seal lubricated with high quality grease for smooth running for flame proof exhaust fan complete all as specified and as directed.
159Material and labour for Condensor 2.5 to 4 mfd for flame proof exhaust fan, oil type complete all as specified and as directed.
160Material and labour for removing the burnt winding of flame proof exhaust fan of any size, cleaning the slot, rewinding with super enameled copper wire of suitable size, varnishing heating and insulating complete all as specified and directed by Engr-in-charge.
161Material and labour for shaft of flame proof fan complete all as specified and directed by Engr-in-charge.
162Supply onlyshackle accessories to hold with fan hook complete with rubber bush, bolt, nut, split pin complete all as specified and directed.
163Material and labour in painting of ceiling fans / exhaust fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.as directed.
164Material and labour fan blade set high quality for 1200 mm sweep fan with fixing screws complete all as specified and as directed.
165Supply and fix louvers for exhaust fan of any size including taking down old unserviceable louvers and removing the material for taking credit complete all as specified and directed.
166Dismantling taking out of unserviceable geyser of any capacity/make/model, transporting to the workshopfor complete over-hauling, testing ofcopper container, rectifying the defects including replacement ofglass wool/insulating material of existing quality and returning to the site at INS Parundu, refixing and connecting up with the water connection and testing including replacement of following parts :- Note :- Replacement ofspareswill be measured and paid for separately under respective items of the schedule here-in-after as supply only.
167Removing thedoor assembly and removing the deposits by scraping or cleaning the element with diluted Hydrochloric acid and flush out sediments deposited in the tank.
168Supply onlyglass lined Incoloy 800 heating element of capacity 2 KW with rubber gasket complete all as specified and directed.
169Supply only capillary type high precision thermostat (2 nos) preferably with highest safety VDE mark suitable for storage type water heater complete all as specified and directed.
170Supply only non-self resetting capillary thermal cutout preferably with highest safety VDE mark suitable for storage type water heater complete all as specified and directed.
171Supply only Steel (SS) braided ,Flexible Hoses (2 nos) having a minimum pressure rating of 8 bar and compatible for hot water applications including making end connections for water inlet/ outlet from/to water heater or to the discharge line complete all as specified and as directed.
172Supply only Anode rod made of aluminium / magnesium .
173Supply only Temperature control knob
174Supply only Heating indicator lamp and power indicator lamp
175Supply only drain valve.
176Supply onlygeyser tank of capacity 25 Ltrs made out of heavy gauge stainless steel with glass enamel coating or coated complete all as specified and directed.
177Supply only multifunction safety relief valve/pressure relief valvesuitable for geyser complete all as specified and directed.
178Supply only brass Non return valve 15 mm/20 mmdia suitable for geyser complete all as specified and directed.
179Supply onlyApparatus plate assembly suitable to fix thermostat, heating elements as ofgeyser and nuts etc complete all as specified and directed.
180Supply only brass Fusible plug
181Painting of water heater (Geyser) up to 25 Ltr capacity with synthetic enamel paint of approved colour over a coat of red oxide after removing of old paint by scratching and filling of cavities with fillers.
182Supply only 3 core 4.0 Sqmm copper conductor cable suitable for geysers of any size complete all as specified and directed.
183Supply and fix 3 pin plug top suitable for metal socket of capacity 25 Amps complete all as specified and directed.
184Removing the tank from the geyser, brazing to arrest the leakage, reassembling and refixing complete all as specified and directed.
185Supply only Bottom inspection chamber cover suitable for 25 Ltrs capacity geyser of any make/model complete all as specified and directed.
186Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand taking down old U/S fittingsfor taking into credit complete all as specified and directed
187Supply and fixing LED light fitting 1x9W/1X10W bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including taking down old U/S fittingsfor taking into credit complete all as specified and directed
188Supply and fixing in replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-charge
189Supply and fixing in replacement LED luminaries 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete including taking down old U/S fittings for taking into credit .
190Supply and fixing in replacement round /square 300 mm x 300 mm shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete including taking down old U/S fittings for taking into credit .
191Supply and fixing in replacements vertical mounting integral highbay/ medium bay in hanger ceiling at 10 meter height LED IP65 luminaries, Luminous Flux 15,000 lm ,Luminous Efficacy (rated) (Nom) 150 lm/W,IP65, IK08 .Surge Protection- Luminaries surge protection level until 4 kV along with necessary chain , hooks to hold the eyebolt & hang the light fitting in hanger complete all as specified and as directed.
192Supply and fixing in replacement LEDsecurity light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.including all accessories and dismantling of old unserviceable fittingfor taking into credit complete all as specified and as directed.
193Supply and fix in replacement LED light fitting 2x 16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size including all accessories and dismantling of old unserviceable fittingfor taking into credit complete all as specified and as directed.
194Schedule of credit amount brought back from Ser Page No. 46- Rs. 1,01,234.00 will be deducted from the above quoted amount to derive the contract sum. SIGNATURE OF CONTRACTOR
Disclaimer :