Tender For Improvement Of Motor Pump Sets With Allied Works At Gandhi Vihar Pumping Station Under Civil Line Zone., Delhi-Delhi

Municipal Corporation Of Delhi has published Tender For Improvement Of Motor Pump Sets With Allied Works At Gandhi Vihar Pumping Station Under Civil Line Zone.. Submission Date for this Tender is 29-02-2024. Supply of Motor Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42393470
Tender For Improvement Of Motor Pump Sets With Allied Works At Gandhi Vihar Pumping Station Under Civil Line Zone.
Open Tender
Indian
Delhi
Delhi
29-02-2024

Tender Details

Improvement Of Motor Pump Sets With Allied Works At Gandhi Vihar Pumping Station Under Civil Line Zone.

Key Value

Document Fees
INR 590 /-
EMD
INR 31216.0 /-
Tender Value
INR 15.60 Lakhs /-

BOQ Items

Name of Work:Improvement of motor pump sets with allied works at Gandhi Vihar pumping station under Civil Line Zone.
Sl. No. Item Description
1DSR Items
2Providing, laying , testing & commissioning of "C" class heavy duty MS pipe confirming to IS 3589/IS 1239 including welding fittings like elbows, tees, flanges, tapers, nut bolts, gaskets etc. and fixing the pipe on the wall/celing with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as reqd. (A) 80 mm dia
3(B) 150 mm dia
4P&F / Replacement of M.S. Black pipe (9.5 mm thickness) confirming to IS:3589 with required nut bolts & packing sheet etc complete as required. 300 mm dia (9.5 mm thick)
5Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312 (Part 1 & 2), PN 1.6 complete as required A) NRV 150 MM
6Replacement of swing type Non Return Valve of CI Body with Door, bronze to Rubber rings confirming to IS 5312 (Part 1&2), PN 1.6 complete as required. B) NRV 300 MM
7Supply installation testing and commissioning of Electrical Horizontal centrifugal pump set with non clog /mf impeller to handle storm / mixed / sewage water with having min. discharge of 800 m3/hr at head min 7 mtr, RPM 750 having suction and delivery size 350 mm or 300 mm dia ,mounted on a common base frame coupled with Min. 40 HP or suitable rating (IE-2) three phase, TEFC AC , 415 volts, 50 Hz supply electrical Motor energy efficient (IE3) complete as required. Mounted on a common base frame as Casing C I, Impeller C I, Shaft & sleeve (SS) 40 C 8 complete with coupling guard and foundation bolts etc. as reqd.
8S/I/T/C of fully automatic Auto Transformer Starter will be constructed / fabricated with 2 mm thick, MS sheet steel, dust & vermin proof,drain & drip - proof, front operated, self supported, free standing type constructions and will be duly spray painted sythetic Enamel paint of Light Grey shade 631 of IS:5 and accommodate all switch -gear items required to meet the technical requirements ofATS 50HP as listed below :- 1- FN 125 , 125 Amp. rating fuse Switch unit (SFU) in open execution. 1 No (L&T) 2-125 Ampere HRC fuse 3 pole , 415 V AC3 Nos. (L&T). 3- 32 Ampere Type -MNX 32 , Power Contactor for Star (L&T) 4- 70 Ampere Type-MNX 70, Power Contactor for Delta 1 No (L&T). 5-80 Ampere Type-MNX 80, Power Contactor for Main 1 No (L&T). 6- Over load Realy MN5 (45-75 Amp.)rating range 1 No (L&T). 7 - ON-Delay Timer 3-30 Sec, I C/o Contact 1 No EAPL/L&T. 8- Push buttons with 1 No element for ON/OFF 2 Nos (L&T). 9- Adequate rating oil immersed Auto Transformer having copper winding, class "E" insulation with taping 60%, 70%, 80%. 1 No (EE) 10 - Single phase preventer realy with under Voltage and over voltage or as suitable 1 No (Minilec) 11- Flush mounting tppe Ammeter 96 sqmm with Selector Switch suitable CT connection 1 No (AE) 12 - Flush mounting type Voltmeter 96 sqmm with Selector Switch 1 No (AE)13- Indicating lamp for ON/OFF , Trip 03 Nos. RASS/Reputed 3 Nos. (L&T) (Without oil ).
9Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 Amp, 30 KA, FPMCCB
10Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 36 KA, FPMCCB
11Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.400 Amp, 50 KA, FPMCCB
12Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole.
13Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
14Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
15Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
16Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
17Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required.
18Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
19Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm
20Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
21Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
22Supplying and making end termination with brasscompression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm).
23Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
24Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm).
25Approved Rate
26Supply,Installation, testing and commissioning of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated , specially designed Al bus bar 400A to 630A with heat shrinkcable colour coated sleeves suitable for accommodating MCCBs/MCBs /Isolators as incoming and outgoing as required (without MCCBs/MCBs/Isolators) complete with digital meter module, including Voltmeter Ammeter with selector switch, CTs control fuse and indicating lights including connections etc. as required ( Conforms to IS:8623).
27Supply & Installation of wall mounted RO plus UV plus UF water purifier with up to 20 L/hr purification capacity and storage tank up to 09 liter capacity.
28Supplying & Installation of Hot Cold & Normal Floor Standing Top Loading Water dispenser with Cooling Cabinet Fridge cold water storage capacity up to 3.5 ltr with hot water storage capacity up to 1 ltr as required.
29Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*50 sqmm
30Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*70 sqmm.
31Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3.5C*150 sqmm
32Providing and fixing of M.S. Flange with required nut bolts & packing sheet etc. complete as required of following Dia. (a) 300 mm (25 mm thickness).
33Providing and fixing of M.S. Bend with required nut bolts & packing sheet etc. complete as required of following Dia. (a) 300 mm short bend c-class.