Tender For Repair/ Maint And Replacement Of Split Ac, Water Cooler, Refrigerator, Desert Cooler And Ac Plant At Cqa (A), Ptl, Sqae , Nai Under Age E/M-Ii (Central) Of Ge(Central) Khadki, Pune-Maharashtra

Military Engineer Services-MES has published Tender For Repair/ Maint And Replacement Of Split Ac, Water Cooler, Refrigerator, Desert Cooler And Ac Plant At Cqa (A), Ptl, Sqae , Nai Under Age E/M-Ii (Central) Of Ge(Central) Khadki. Submission Date for this Tender is 19-03-2024. Air Cooler Tenders in Pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

42374762
Corrigendum : Tender For Repair/ Maint And Replacement Of Split Ac, Water Cooler, Refrigerator, Desert Cooler And Ac Plant At Cqa (A), Ptl, Sqae , Nai Under Age E/M-Ii (Central) Of Ge(Central) Khadki
Open Tender
Indian
Maharashtra
Pune
19-03-2024

Tender Details

Repair / Maint And Replacement Of Split Ac, Water Cooler, Refrigerator, Desert Cooler And Ac Plant At Cqa ( A ) , Ptl, Sqae , Nai Under Age E / M-Ii ( Central ) Of Ge ( Central ) Khadki

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 97660.0 /-
Tender Value
INR 48.83 Lakhs /-

BOQ Items

Name of Work:REPAIR/ MAINT& REPLACEMENT OF SPLIT AC, WATER COOLER, REFRIGERATOR, DESERT COOLER & AC PLANT AT CQA(A), PTL, SQAE, NAI UNDER AGE E/M-II (CENTRAL) OF GE(CENTRAL) KHADKI
Sl. No. Item Description
1M & L for Copper piping 5/8" (18/20 gauges) with necessary fitting such as elbow bends sockets and tee"s , clamps and supports on wall and grounds.
2M & L for Copper piping 1/2"with necessary fitting such as elbow bends sockets and tee"s , clamps and supports on wall and grounds or frame etc.
3M & L for Copper piping 1/4" with necessary fitting such as elbow bends sockets and tee"s , clamps and supports on wall and grounds.
4M & L for Copper piping 5/8" superlone insulation with necessary fitting such as elbow bends sockets and tee"s , clamps and supports on wall and grounds.
5M & L for Copper piping 1/2" superlone insulationwith necessary fitting such as elbow bends sockets and tee"s , clamps and supports on wall and grounds.
6M & Lfor Copper piping 1/4" superlone insulationwith necessary fitting such as elbow bends sockets and tee"s , clamps and supports on wall and grounds.
7Labour for Shifting of split type air conditioner and fixing of air conditioner all as per directed by Engr-In-charge.
8M&L for core cutting/drilling/chease cutting of wallup to 18 inch suitable for split type ac as per site requirmentall as per directed by Engr-In-Charge
9Disconnecting split/window type AC (Outdoor+Indoor unit) 1.5/2 TR electrically/mechanically and lowering to the ground fixed in any position for servicing/repairing/overhauling/cleaning, and cleaning filters, checking of electrical wiring, cleaning of dust by blower and washing with washing sodaincluding replacement of unserviceable, burnt out spare parts to make it fully functional, after repair and re-installation and testing on full load completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site. Note :- Item replaced will be measured and paid separately.
10M & L for cleaning gas system of split AC/Window type AC with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas ( Refrigerant R-22) including brazing/testing and commissioningcompleteof size 1.5/2 Ton capacity.
11M & L for cleaning gas system of split AC/Window type AC with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas ( Refrigerant R-32) including brazing/testing and commissioningcompleteof size 1.5/2 Ton capacity.
12M & L for cleaningof gas system of the water cooler/ refrigerator with carbon tetra chloride chemical & flushing with Nitrogen and charging the gas ( R-134) including brazing/testing and commissioningcomplete of capacity 40/80/100/120 ltrs .
13M&L for replacement of unserviceble & damaged burnt blower motor/fan motor Window/Split AC of capacity 1/6 HP.
14M&L for replacement of unserviceble & damaged burnt blower motor/fan motor Window/Split AC of capacity 1/4 HP
15M&L for replacement of unserviceble & damaged burnt blower motor/fan motorof Water cooler of capacity 1/8 HP
16M&L for replacement of unserviceble & damaged burnt blower motor/fan motor Window/Split AC of capacity 1/3 HP
17M&L for replacement of unserviceble & damaged burnt blower motor/fan motor Window/Split AC of capacity 1/2 HP
18Disconnecting Water cooler of 60/40/80/100/120 Ltr electrically/mechanically for repairing/overhauling/cleaning, checking of electrical wiring, cleaning of dust by blower including replacement of unserviceable, burnt out spare parts such as relays thermostates etc to make it fully functional, after repair and re-installation and testing on completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site. Note :- Item replaced will be measured and paid separately.
19S & F for micro processor printed circuit board comlete suitable for splittype AC of 1.5/2 TR as suitable for existing make/model and capacity 1.5/2 Ton and all as per existing.
20Disconnecting and taking out old defective Hermetically sealed compressor unit as required for AC/water coller/refrigerator and M&L for fixing new compressor (newsealed unit only)withnut bolt, washer antivibrating bush , brazing work,pressure testing for leakage, vaccumnsing and gas charging etc of capacity 1.5 TR for window/Split AC of the existing makes:-Voltas/Hitachi/Emersion/ Carrier /Shriram(Techmesh) .
21All as per item no 20 above but of capacity 2 TR for window/split AC
22All as per item no 20 above butsuitable for Water cooler of capacity 40ltrs.
23All as per item no 20 above butsuitable for Water cooler of capacity 60ltrs.
24All as per item no 20 above but suitable for Water cooler of capacity 80ltrs.
25All as per item no 20 above but suitable for Water cooler of capacity 100/120ltrs.
26S & F in replacementthermostate suitable for water cooler/ refrigerator/ AC of any type and any model complete.
27M&L for replacement of overload protection relay for window AC,water cooler and refrigerator ofmake and model as per existing.
28M&L for replacement of starting relay for window A/C water cooler & refrigaretor of make and model as per existing.
29S & F in replacement of running capacitor 10 MFD , 440 V
30S & F in replacement of running capacitor 25 MFD, 440V
31S & F in replacement ofrunning capacitor 36 MFD, 440V
32S & F in replacement of running capacitor 40/45 MFD, 440V
33S & F in replacement of startingcapacitor 60 MFD, 440V
34S & F in replacement of startingcapacitor 80/100 MFD, 440V
35S & F in replacement of startingcapacitor 120 MFD, 440V
36S & F in replacement of PVC float valve for water cooler of size 15mm dia.
37S & F in replacement of drier filtter for AC/water cooler/refrigerator.
38S & F in replacement of capillary copper/MS/PVC tubing of any size not less than 0.5 mtr for AC/Water cooler/refrigerator.
39S & F for PVC drain pipe suitable for water cooler outlet of any capacity..
40S & Fin replacement 3 pin plug top of capacity 15 amp , 240V, 50HZ.
41S & Fof Copper Condenser unit assembly for window AC with all accessories complete of capacity 1.5/2 ton.
42S & F in replacement of suction brass valve for split ACof any capacity.
43S & F for PVC drain pipe 20mm suitable for split AC out let of 1.5T/2.Tcapacity.
44S & F in replacment of discharge brass valve for split ACof any capacity.
45Replacement of rubber gasket for lid top of any size for water coolers.
46S & F hermetically sealed unit new Compressor by dismantling burnt out u/s Compressor suitable for refrigirators with bushes, sleeves, washers nut and bolt for Compressor foundation legs, relay terminal cover clips and including cutting, brazing, leak detection, charging refrigerent and commissioning testing for 165 - 200ltr capacity.
47Disconnecting Electric conection, removing/transporting the unsv water cooler of capacity 40 ltrs to 120 Ltrs to workshop for paintingworkwhich includes removing the existing deteriorated/rusted body for paint by scrapping and filling of cavaties with filler spray, denting/ welding, patch work with existing size of MS sheet and painting the body with synthetic enamel paint two coats over a coat of redoxide and marking the SM/MES No (of reqd size and shape) with black paint complete all as specified for as directed by Engr-in-Charge.
48M & L for dismantling of existing unservicebale voltage stablizer for repairs with replacement of relays electronic voltage sensor circut and meter, micro switch, indication light RC filters and other connected items for making functionaland rewinding of unserviceable transformer with super enameled copper wire of appropriate size, varnishing assembling and testing completeofcapacity 2 KVA to 5 KVA upto satisfactory function of any capacity all as directed by Engr- in-Charge.
49S&Fof Heavy duty air conditioner outdoor unit stand/ brackets with complete accessorise for windos/split AC of capacity of 1.5/2 Ton complete with grouting nut bolts all as specified and as directed by Engr-in-charge .
50S & F in replacment of Copper Condenser unit assembly for Outdoor Unit with all accessories suitable for split ACof capacity 1.5/2 ton complete .
51Dismantling of old split type air conditioner indoor unit and Supply , installation and testing Indoor unit of split type air conditioner complete with cordless remote control and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 Ton with wall mounted fixing plate suitable size incl breezing work for fixing existing site complete all as directed. Make - Voltas / LG / Blue star
52Disconnecting Desert cooler of any capacity and type by electrically/mechanically for repairing/overhauling/cleaning, checking of electrical wiring, cleaning of dust by blower including replacement of unserviceable, spare parts such as capacitor , selector switch , grass pad set etc to make it fully functional, after repair and re-installation and testing on completion to the entire satisfaction of Engr-in-Charge including transporting to workshop and back to site.Note :- Items as declared unservicable by Engineer in charge shall be replaced and measured in quoted rate of this item .
53Disconnecting and taking down unserviceable/damage outdoor unit cover of split air conditionerof capacity 1.5 Ton and dismantaling of compressor ,condenser unit,wiring,fan motor from outdoor cover and supply and fixing new outdoor cover with replacement of unserviceable spare parts such as capacitor ,control wiring and refixing compressor ,condenser unit,wiring,fan motor to make it fully functional, after repair and re-installation as per existing and testing on completion to the entire satisfaction of Engr-in-Charge. Note :- Items as declared unservicable by Engineer in charge shall be measured and paid separately.
54S & F sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 4 Sqmm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit of 1.2 mm wall thickness including all fixing accessories, and 4 sqmm PVC insulated multi stranded copper conductor cable as earth wire connected to earth dolly complete all as specified and directed by Engr-in-charge.Note:- Both running cables including earth wire including one run pvc conduit pipe shall be measured & paid for as single length.
55S & F sub main wiring of two single core FRLS-H PVC insulated unsheathed stranded copper conductor cables of size 6 Sqmm, 1100 volts grade, drawn through and including 20 mm dia PVC surface conduit of 1.2 mm wall thickness including all fixing accessories, and 6 sqmm PVC insulatedmulti stranded copper conductor cable as earth wire connected to earth dolly complete all as specified and directed by Engr-in-charge. Note:- Both running cables including earth wire including one run pvc conduit pipe shall be measured & paid for as single length.
56S & F of MCB"s 240V confirming to IS of rating 6A to 32A SP," C" Series, 10 KA breaking capacity complete all as directed by Engr-in-Charge.
57S & F sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin and earthplug and socket complete with one no MCB SP , 20 Amps , 230 volts complete all as specified .
58S & F in repairs First Aid Box at E/M installations to keep the first aid items i.e. Tube of bernol, Bandage, one small snizer, banded etc, the box made out of GI sheet of 18 gauge of size 30 cm X 25 cm x 20 cm with openable window & writing letters "FIRST AID" with thick red paint and fixed on wall at height not less than 2 mtr complete all as directed and specified by Engineer- In- Charge.
59S & F in repair CI Pot Strainer/ Y Stainer with matching flanges, gasket, hardware of 150mm boreall as specified and directed of following sizes as per site requirment.
60S & F panel mounting for digital ammeter 3 phase, 3 wire, Display type red LEDwith selector switch and suitable CT"s for each phase all as per existing and directed as per following makesM/s AE/ Sutaria/ HPL
61S & F in repair installation informatory boards at E/M installation to display the technical details i.e.(Type of AC plant, capacity, Design condition, Date of installtion, Installed by, Compressor type, Compressor motor, Condensor motor, AHU motor, cooling tower motor, AHU motor and if chilled water type chiller motor) of AC plant made out of 3mm thick aluminium composite panel (ACP) fully covered with white/green/blue (as required) Retro Reflective sheeting of Nikkalite Brand Ultralie (UL) grade with using pressure sensitive adhesive and Retro Reflective cut out border and messages in the sensitive adhesive, size of the board 150 cm x 120 cm fixed on wall above 1.2 mtr above ground level with & including proper fixing arragement complete all as specified and directed. Note: Technical details as per direction of Engr-in-charge.
62Disconnecting water connections to the condenser of package/central A/C plant of following capacity by dismantling the both end cover of condenser. Descaling the condenser of compressors with dilute sulphuric acid , flushing/cleaning with brush and water, re-fixing the side cover with new gasket nut / boltsand detect leakage all as specified and directed by Engineer -in-Charge.Note : Dilute sulphuric acid for descaling is deemed to be included in the quoted rates.
63M & L for Servicing/Cleaning of FRP cooling tower of 100 TR by dismantling top cover, fan with fan motor and removing the honey comb frills. Cleaning of base tray & frills, pot strainer etc. servicing of fan motor with changing of bearings and greesing refixing the fan, frill & top cover testing commissioning complete all as directed by Engr-in-charge.Note : Spares as required during the servicing and repairs as declared unservicable by Engr in charge shall be mesured and paid under relavant items of this schdule.
64Disconnecting/Isolating the compressor of make :- Voltas 05060S model from the system by putting plates to the suction and discharge valve opening of the compressor. Dismantling the compressor completely by taking down the crank shaft. Removing unserviceable internal parts cleaning overhauling complete replacement of worn out parts such as suction reed, discharge reed, cylinder liners, loading/unloading system of compressor, washers, nut bolts, gaskets shaft seal, "O" rings, cutting, metalizing, grinding, balancing the crank shaft and reassembling the compressor including changing the compressor oil, leak testing with nitrogen, repairing leakages and charging R-22, gas, testing/comissioning complete for following compressor make Accel sabro/Kirloskar, complete all as directed by engineer in charge. Note :Spare parts , R-22 gas, compressor oil and nitrogen gas shall be measured and paid separately under respective items. Note :- Item replaced will be measured and paid separately.
65S & F in replacement of following spares for compressor make :- Voltas 05060S model. all as specified &directed by Engr-in-charge.
66Piston
67Piston ring
68Pisotn pin
69Shaft seal assembly
70Discharge valve reeds
71Loading Unloading Frame
72Main bearing Bush
73CR bearing
74Gasket set for 05060S
75Aluminium washer set
76Oil pump assembly
77Oil ring
78O Ring set
79Solenoid valve for loading & unloading
80Split pin
81Sunction valve reed
82Thrust collor
83Oil filter
84Cylinder liner
85Oil drain valve
86Bushing for connecting rod
87Supply and filling nitrogen gas for leak testing of central & package A/C plants all as directed by Engr-in-charge.
88Supply and filling of R-22 Gas in central & package A/C plants all as directed by Engr-in-charge
89Supply and fillling compressor oil suitable to air conditioning plants compressor and taking out old dirty compressor oil, cleaning the crank case and oil filter all as directed by Engr-in-charge.
90Supply and fixing in replacement of defectivebrassomatic pressure releas valve of suitable size for 300 PSI refrigerent gas pressure complete complete all as specified and directed by Engr-in-charge.
91S & F in replacement of over load relaystype MN relay range 14-23 Acomplete all as specifiedby Engr-in-charge.
92S & F in replacement of over load relaystype MN relay range 24-40 Acomplete all as specifiedby Engr-in-charge. .
93S & F of MCCB 63 Amps 25KA, TP (ICS=100%ICU)with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specifiedby Engr-in-charge.
94S & F of MCCB 100 Amps 36KA, TP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specifiedby Engr-in-charge.
95S & F of MCCB 125 Amps 36KA, TP (ICS=100%ICU)with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specifiedby Engr-in-charge.
96S & F of MCCB 200 Amps 36KA, TP (ICS=100%ICU)with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specifiedby Engr-in-charge.
97S & F of MCCB 200 Amps 36KA, FP (ICS=100%ICU) with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit completeall as specifiedby Engr-in-charge.
98S & F of MCCB 250 Amps 36KA, FP (ICS=100%ICU)with Adjustable thermal magnetic release in the control panels including dismantling of old unsv MCCBs/SFU fuse unit complete all as specifiedby Engr-in-charge.Note : For item No 18.00 to 23.00 - (i) All cable connections should be done with supply and fixing suitable size lugs/thimble etc. (ii) Any addition / alteration to sheet metal enclosure existing panel for fixing of MCCBs and removal of old u/s switch gear is deemed to be included in the rates quated.
99S & F in replacement of followingspares for central AC plant100TR
100Indicating lamps RYB - 01 Set
101"V " belt of size / No A 1052 LP/A 40
102V " belt of size / No A 925 Lp/A 35
103Power Contactors ML A2
104Power Contactors MNX 12
105Power Contactors MNX 18
106Power Contactors MNX 45
107Power Contactors MNX 70
108Labour only for detection of leakage and repairing of central type AC Plant of capacity 100 TRcapacity by leak testing, leak repairing, pressure testing with nitrogen, vaccumising complete system of central type AC plant with double stage vaccume pump of atmospheric pressure less than 28 to 30mm/HG and charging of refrigerant gas upto required pressure after satisfactory results. Note :- Nitrogen gas and refrigerant will be measured and paid separately.
109Dismantlingof Air Handling Unit of any capacity with complete accessories such as cooling coil ,air filters,blower motor, blower / drum ,blower shaft,side panels , and wall opening if required etc including removing of electric connection and dismantling of pipe work of any size and type by using gas cutter or Electric cutter complete all as specified and directed by Engr-in-charge.
110Re-assembling/Refixing thecomplete Air Handling Unit of any capacity after carring out cleaning, servicing to cooling coil, blower & filters by usingCTC solutionincluding remetling ,fine grinding blower shaft and hardening balancing , realignment to AHU shaft, replacing unserviceableblower fins ,replacing bearings 2 Nos including inlet out let pipe welding,all electric connections and leak testing by using nitrozen gas and testing and commissioningall as specified and directedby Engr-in- Charge
111S & F Cast iron Sluice valves class PN 1.6 of size 150mm dia (6") stainless steel spindle incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valvescomplete all as specified and directed Engr-in-Charge.
112S & F Cast iron Sluice valves class PN 1.6 of size 100mm dia (4") stainless steel spindle incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valvescomplete all as specified and directed Engr-in-Charge.
113S & F Cast iron Sluice valves class PN 1.6 of size 80mm dia (3") stainless steel spindle incl gasket , nutbolts,handle with cuting of ci pipe fabrication work as per site requirment & incl removal of Unsv Sluice valvescomplete all as specified and directed Engr-in-Charge.
114Taking out unserviceable liquid line valve/discharge line valve from refrigerant line of different size/type for necessary replacement all as directed including cutting / welding of existing pipe line completeall as specified and directed Engr-in-Charge.
115S & F liquid line valve/discharge line valve of size 40mmas perexisting including providing Gasket/Teflon/bushing to both side sheet, suitable for 40 mm dia pipe line including brazing/welding,fixing complete all as specified and directed Engr-in-Charge.
116S & Fliquid line valve/discharge line valve of size 25mm as perexisting including providing Gasket/Teflon/bushing to both side sheet, suitable for 25 mm dia pipe line including brazing/welding,fixing all as diected and specified by Engr-in-charge.
117S & F liquid line valve/discharge line valve of size 20mm as perexisting including providing Gasket/Teflon/bushing to both side sheet, suitable for 20 mm dia pipe line including brazing/welding,fixing completeall as specified and directed Engr-in-Charge.
118S & F thermostate expansion valve of suitable size for 100TRcapacity air conditioning plants including taking down the unserviceble valve.
119S & F water pressure gauge 0-7Kg/Sqm including taking down the unserviceble gauge.
120Supply& fixing refrgerant pressure gauge 30 to 150 PSI including taking down the unserviceble gauge.
121S & Fin replacement of pressure release valve ofcondensor 3/8" BSPthreaded suitablefor 300 PSI
122S & F in replacement ofDB/WB thermometer wall mounted with the facility of RH readings all as per existing.
123Taking down carefully and overhauling of Monoblock pump set by disconnecting the pump from foundation and pipe line, dismantling of shaft from the pump, replacing the unserviceable wornout bearing, gland packing, seal and bushing and assembling after repairs complete testing for the pump of Capacity 7.5 HP to 10HP
124M & L in replacement of 50mm bore GI pipe medium grade incl all fitting and acessories completeall as specified and directed Engr-in-Charge.
125M & Lin replacement of 40mm bore GI pipe medium grade incl all fitting and acessories completeall as specified and directed Engr-in-Charge..
126M & Lin replacement of 25mm bore GI pipe medium grade incl all fitting and acessories completeall as specified and directed Engr-in-Charge.
127M & L in replacement of 20mm bore GI pipe medium grade incl all fitting and acessoriesall as specified and directed Engr-in-Charge.
128S & F Gate Valves (Brass Insert) of 50 mm bore, ISI marked , heavy duty incl taking down old one completeall as specified and directed Engr-in-Charge.
129S & FGate Valves (Brass Insert) of 40 mm bore, ISI marked , heavy duty incl taking down old one completeall as specified and directed Engr-in-Charge.
130S & FGate Valves (Brass Insert) of 25 mm bore, ISI marked , heavy duty incl taking down old one completeall as specified and directed Engr-in-Charge.
131S & FGate Valves (Brass Insert) of 20 mm bore, ISI marked , heavy duty incl taking down old one complete all as directed
132S & F float valve/ball type assemblt complete of size 20 mm size dia.
133Painting of CI/GI/MS pipes of Air / Water distribution of size 100 / 80 mm dia along with side supports complete with two coats of synthetic enamel paint all as per colour code directed by Engr-in-Charge.
134M&L painting to cooling tower inside and outside with one coat of primer and one coats of epoxy paint of approved colour including scapping out the old paint complete all as specified and and directed by Engr-In-charge.
135M&L for preparation of surfaces for painting of compressor unit of capacity up to 100 TR with motor, one coat of synthetic enamel paint including painting to suction line, discharge line, liquid line , guard base foundation etc. all as specified and as directed by Engr-in-charge
136M & L for Mild Steel brackets, frames ,supports, channels and stands of type as required at site made out of angle iron,flat or strip of grade Fe-410-S of any size as per site requirement for PGI air duct etc complete all as specified and as directed by Engr-in-charge .
137S & Fdouble nitted polymer fabric HDPE fresh air filter washable/cleanable type having efficiency 95% to 99% down to particle size of 5 to 20 micron, fabricated out of CRCA sheet metal duly painted with two coat of grey hammer tone spray painted over two coats of red oxide primer, with lifting handle, Box/flanged type, aluminium spacer etc, all as specified by engr-in-charge of sizes 610 x 610 x 50 mm.
138Supply , laying,commissioning and testingXLPE insulated ,armoured heavy duty electric cableAluminium conductor, 1100 volt cross sectional area 70 Sqmm 3.5 core incl removing unserviceable/old cablecomplete all as specified and as directed by Engr-in-charge.
139Supply , laying,commissioning and testingXLPE insulated ,armoured heavy duty electric cableAluminium conductor, 1100 volt cross sectional area 50 Sqmm 3.5 core incl removing unserviceable/old cablecomplete all as specified and as directed by Engr-in-charge.
140Supply , laying,commissioning and testingXLPE insulated ,armoured heavy duty electric cableAluminium conductor,1100 volt cross sectional area 35 Sqmm 3.5 core incl removing unserviceable/old cablecomplete all as specified and as directed by Engr-in-charge.
141Supply , laying,commissioning and testingXLPE insulated ,armoured heavy duty electric cableAluminium conductor,1100 volt cross sectional area 25 Sqmm 3.5 core incl removing unserviceable/old cablecomplete all as specified and as directed by Engr-in-charge.
142Supply , laying,commissioning and testingXLPE insulated ,armoured heavy duty electric cableAluminium conductor,1100 volt cross sectional area 16 Sqmm 4 core incl removing unserviceable/old cablecomplete all as specified and as directed by Engr-in-charge.
143Supply , laying,commissioning and testingXLPE insulated ,armoured heavy duty electric cableAluminium conductor,1100 volt cross sectional area 6 Sqmm 3 core incl removing unserviceable/old cablecomplete all as specified and as directed by Engr-in-charge.
144M & Lfor disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire "H" Class of same size to get the same output of motorincluding material such asvarnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 7.5 HP to 12.5 HP all as specified and directed by Engr-in-charge.
145M & L for for disconnection/dismantling of electric motor 3 Phase, 415 Volt, from installation & transporting to workshop for rewinding , taking out old unserviceable burnt winding and rewinding the same with super enamelled copper wire "H" Class of same size to get the same output of motorincluding material such asvarnish, sleeves, leothariod paper etc and refixing the same in position with proper alignment, balancing and testing of capacities 40 HP to 60 HP all as specified and directed by Engr-in-charge.
146M & L for fabrication and installation of glow Sign board (640 cm x 91cm x 25cm) made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having with intenal tube light fitting arrangement to open the flex/Acrylic board and suitable for mounting on wall/ gate complete all as directed by engr-in-charge. Note :- The cost of Fabrication and welding work is included in the quoated rate .
147M & L for fabrication and installation of Sign board (240 cm x 91cm x 25 cm) made of Flex/Acrylic board, with computer imaging matter is directed by engr-in charge at one side of the board, GI plain sheet, cubicle housing having arrangement to open the flex/Acrylic board and suitable for mounting on wall complete all as directed by engr-in-charge. Note :- The cost of Fabrication and welding work is included in the quoated rate .
148S & F of hony comb frills ( of FRP cooling tower ofany capacity by dismantling top and bottom honey comb frills size of frill as per site requirment, testing commissioning complete all as directed by Engr-in-charge. Note :- The cost all required material is included in the quoted rate .
149Supply & Fix Mild steel pipe heavy grade of 100 mm dia with all fitting laid in floors and fixed to walls and ceilings etc of sizes as showncomplete all as specified and directed byEngr-in-charge
150S & FMild steel pipe heavy grade of 80 mm dia with all fitting laid in floors and fixed to walls and ceilings etc of sizes as showncomplete all as specified and directed byEngr-in-charge
151M & L for insulation of MS Pipesof any size with Nitrile rubber insulation of 20mm thick with and applying bituminous compound complete all as specified and directed byEngr-in-charge
152M & L for insulation of MS Pipesof any size with Nitrile rubber insulation of 25mm thick with and applying bituminous compound complete all as specified and directed byEngr-in-charge
153M & L for fibre glass cloth at nitrile rubber insulation on any size of pipe Complete all as specified & directed by Eng-in-Charge.
154M & L for insulation of MS Pipes of any size with cladding of 26 SWG Aluminium Cladding sheet complete with all bends ,fittings all as specified and directed byEngr-in-charge