Tender For Beautification Work Of Ghanta Ghar., Ajmer-Rajasthan

Department Of Local Bodies has published Tender For Beautification Work Of Ghanta Ghar.. Submission Date for this Tender is 29-02-2024. Gardening Tenders in Ajmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42369711
Tender For Beautification Work Of Ghanta Ghar.
Open Tender
Indian
Rajasthan
Ajmer
29-02-2024

Tender Details

Tender For Beautification Work Of Ghanta Ghar.

Key Value

Document Fees
INR 1000 /-
EMD
INR 140000.0 /-
Tender Value
INR 70 Lakhs /-

BOQ Items

Name of Work :?kaVk?kj dk lksUn;Zdj.k ,oa fuekZ.k dk;ZA
Sl. No. Item Description
1Cleaning and removal of earth, silt, sludge, kankar, boulder, building material and garbage in existing nallah/drains including construction of bye pass arrangement to byepass water with 1.5m lift from ground level and lead upto 50 mincluding foul & saturated condition where pumping out or bailing out of water is required, including shoring, shuttering where required and dewatering. Making access for disposal and dressing disposal side as per the directed of the Engineer.
2Earth work in excavation in foundation, trenches manholes, roads side chambers etc including dressing of sides and ramming of bottom, including getting out the excavated material, refilling after laying pipes/foundation, dewatering and disposal of excavated material at a lead up to 50 m suitable site as per direction of Engineer for following depth, below natural ground/Road top level
3Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. clock tower
4Stone Kharanja (soling) Random rubble dry stone Kharanja (soling) under floor.
5Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level in 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size).
6RR Masonry for Foundation : Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)
7Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
8RCC : Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand: 2 graded stone aggregate 20 mmnominal size). (As per design mix)
9Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1:2 (1 cement : 1 coarse sand: 2 graded stone aggregate 20 mmnominal size). (As per design mix)
10Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 gradedstone aggregate 20 mm nominal size) -As per design mix) Plinth Beam,lintel beam and slab beam
11Steel fabrication " Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars.@ 120 kg /cum
12Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :(a) Suspended floors, roofs, landings, balconies and access platformRoof slab
13(b)Lintels, beams, plinth beams, girders, bressumers and cantilevers.
14(c) Columns, Pillars, Piers, Abutments, Posts and Struts.
15Extra for shuttering in circular work (20% of respective centring and shuttering items).
16Add extra for doing centering and shuttering work for each subsequent storey above two storey.
17Plaster 15 mm (Internal plaster- in CM 1:4) Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine/ coarse sand)
18Plaster 20 mm (Externalplaster) (Cm 1:6) : Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix :
19Plaster 12 mm (Externalplaster) (Cm 1:4) : Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix :
20Flooring :Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.
21Heritegework : Providing and fixing fine dressed sand stone/approved stone Traditional work as per existing matching geometrical design ncluding molding work with fine finishing,fixing with thambli by proper adhesive and white cement with pigment including making groove etc. complete in all respect.
22Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for separately) : Red sand stone - exposed facefine dressed with rough backing.
23Wall lining butch work upto 10m height with red/ white sand stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75x75mm and by providing layer of75mm thick strips i/c12mm thick bed of cement mortar 1:3 (1 Cement : 3 coarse sand)i/c ruled pointing in cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment to match the shade of stone complete as per direction of Engineer-in-charge.
24Providing new /restoration of decorative sandstone columns as per the original details found on site of size around 2.1 to 2.5 metres in height & (square/ rectangular upto 200 mm x 400mm ). The damaged portions of the original column to be carefully dismantled without damaging the adjacent areas, & replacing the same with new detail of the same size & design. Sample of the terra cotta column to be shown to the Engineer in charge for approvals before procuring & fixing the same on site. Item to include all necessary anchoring details, scaffolding if required etc. complete. Mode of Measurement: Item to be paid each restored/new column.for using plain
25Add extra for Decorative/Ornamental Stone Carving Workwith fine finish making motifs, flowers, geometrical designs etc.as per direction of Engineer Incharge.
26Providing and fixing fine dressed sand stone " Gardanaof sand Stone " on top of the wall at vrandha as per existing matching , fixing in grinded lime surkhi mortar 1:2 including pointing in cream and stone powder 1:1 with an admixture of pigment to match the shade of stone complete in all respect. above100 mm to 150 mm thick plain with fine dressing.
27Making Mehrab"s, Arches, pillars, highly decorative creepers, flowerof small sizes etc.in lime Surkhi plaster (1:2) as per B248old traditional practices (Arches, Mehrab"s) in three coats for base course and subsequent course and Loi tamping, beating till the shrinkage cracks are disappear than making ornamental flowering/design etc. The work is to done with all leads and lifts as per work of restoration nature as per Jaipur practice.
28Khamira Colour Washing as per old traditional practice to prepare the Khamira the lime should be slaked at least for 7-10 days and regularly it should be stirred by adding cured, Gugal, for nonsynthetic colour adding gum (babool gum) as per specification. Then applying prepared solution on walls three to four thin coats as desired finishing.inside of clock tower
29Providing and fixing red sand stone brackets 55x22.5x45cm sunk and moulded including providing and fixing with 4 Nos. gun metal cramp 25x6mm30 cm long and dowel bars 7.5 cm long 6 mm dia as per design.
30Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade:White sand Stone
31Providing and fixing stone jali 40mm thick throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. White sand stone
32Providing and applying breathable, non-reactive, transparent, antifungal, UV resistant, alkaline stable, impregnable silane-siloxane or equivalent based water repellent coating on exposed absorbing substrate like stone surface/ concrete surface/ mineral painted surface / exposed brick surface / lime surface in two or more coats to give uniform finish surface in all heights, horizontal, inclined, vertical and on ceiling complete in all respect and making it complete water-proof as per direction of the Engineer-in charge.
33Rain water pipe : Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes:
34Rain water pipe fittings : Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Bend 87.5° 110 mm bend
35Shoe (Plain) 110 mm Shoe
36Ceiling Fan clamp : Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar :
37Door frames Providing and fixing double paitam (rebated) stone doors windows and ventilator frames of approved quality in cement sand mortar 1:4:
38Providing& fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Ivory coast wood Grade I
39Flush Door shutters: Providing and fixing external grade board solid core single leaf flush door shutters ISI 220267 marked using Phenol formal dehyderesin in glue both sides including approved ISI marked Stainless Steel butt hinges fittings with necessary screws complete as per annexure "A": Decorative teak veneer both side
40Providing laminated veneer lumber conforming to IS:14616 and TAD -15: 2001( Part B) in factory made frames of doors, windows, clerestory windows and other frames, wrought framedand fixed in position as per directions of Engineer-in-charge.
41Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including black enamelled ISI marked M.S butt hinges with necessary screws.
42Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer.
43Structural steel work in single section fixed with or withoutconnecting plate including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete.
44Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately For the purpose of measurement the entire treated surface will be measured.
45Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
46Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq.mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it"s accessories, round tiles,18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point. 6 A switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. Short point (up to 3 mtr.)
47Medium point (up to 6 mtr.)
48Long point (up to 10 mtr..)
49Wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq.mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it"s accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 A switch, 6 A socket, 3.0 mm thickphenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. Short point (up to 3 mtr.)
50Medium point (up to 6 mtr.)
51S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit as per PWD specification for electrical Works along with its accessories (IS: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, referAnnexure "A" attached with this BSR .25 mm
52P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as required. Short point (up to 3 mtr.)
53Medium point (up to 6 mtr.)
54Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load andsite requirement) 4KV impulse withstand voltage,as per PWD specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted withexisting distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A ratingincluding making connections, testing etc. as required.. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 6 A to 32 A rating
55Providing & Fixing of 240/415 V isolator as per PWD specification for electrical Works with ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization catagory, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm. , label holding facility , IP 20 contact protection and fitted with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . Double pole isolator
56Providing & Fixing of IK09 recessed/surface mounting heavy duty horizontal type sheet steel not less then 1.2 mm thick Distribution board as per PWD specificationfor electrical Works ISI marked conforming to IS-13032 & IS-8623 / conforming to IEC 61439-3. Phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal DBterminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediatedlab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . IP-43 Double door (Three phase)
57Providing & Fixing of recessed/surface mountingtype sheet steel / Plastic enclosure as per PWD specificationfor electrical Works conforming to IEC 61439-3 of not less then 1.2 mm thick for housing MCB/Isolator with Din rail including , all as per pre approved by Engineer in charge,making connections,with lugs, repairs etc. as required.OEM shall have submitNABL / CPRI / ERDA accrediatedlab test reportsbefore execution & All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . . With sheet steel enclosure (One /two way)
58Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Red sand stone
59Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-incharge. In cement mortar
60Dismantling tile work in floors and roofs laid in cement mortarincluding stacking material within 50 metres lead.
61Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. completeand stacking within 50 metres lead : Of area 3 sq. metres and below
62Demolishing thatch roofing including mats, bamboo, jaffari etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
63Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting theis mantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer. Prestressed /Reinforced cement concrete with separating, cleaning, straightening and cutting of bars
64Providing and fixing Barricading at site of work for restricting the general public using 80-100 mm dia Wooden Ballies as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing suitably two rows of 100mm wide PVC Tape preferably of red colour. The vertical members shall be painted in red and white colour strips as per approved pattern as and when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading holes shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail