Tender For External Lighting Arrangement At Maintenance Of Model School Jaora Ratlam Mp, jaora-Madhya Pradesh

Board Of Secondary Education-CBSE has published Tender For External Lighting Arrangement At Maintenance Of Model School Jaora Ratlam Mp. Submission Date for this Tender is 28-02-2024. Decoration Work Tenders in jaora Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42358964
Tender For External Lighting Arrangement At Maintenance Of Model School Jaora Ratlam Mp
Open Tender
Indian
Madhya Pradesh
jaora
28-02-2024

Tender Details

External Lighting Arrangement At Maintenance Of Model School Jaora Ratlam Mp

Key Value

Document Fees
INR 2000 /-
EMD
INR 38430.0 /-
Tender Value
INR 19.21 Lakhs /-

BOQ Items

Name of Work:External Lighting arrangment and Maintenance of Model School Jaora.
Sl. No. Item Description
1Providing and erection of hot dipped galvanized octagonal poles in single section made from 3mm thick sheet having lockable weather proof flush door junction box, suitable size & type of foundation bolts 4 nos. "J" type (EN8 grade) complete, erected in an approved manner on provided foundation.6 meter height 130 X 70mm A/F, 220x220x12mm base plate, 4 nos. X 20 x 600mm bolt
2Providing and fixing of bakelite sheet 10mm thick, one MCB 6Amp-32Amp SP & 16sq.mm stud type 4 way epoxy connector for decorative designer poles /octagonal pole box.
3Providing and fixing of sword canopy type single arm GI bracket upto 2 meter Long for 70mm A/F top octagonal pole
4Providing and fixing of sword canopy type double arm GI bracket upto 2 meter Long for 70mm A/F top octagonal pole
5Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tar steel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-in-charge
6Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job.90Watt, color temp 3000-6500k as required.
7Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.150Watt, color temp 3000-6500k as required.
8Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor
925 sq. mm, 3½ core armoured
1010 sq. mm, 4 core armoured
11Laying of one number armoured / unarmoured power cable 1:1 KV grade of size not exceeding 25 sq. mm in the existing RCC hume/stone ware/G.I. pipe/surface in existing trench as required.
12Laying of one number armoured / unarmoured power cable 1.1KV grade of size not exceeding 25 sq. mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required.
13Laying of one number armoured/unarmoured cable 1.1KV grade of size not exceeding 25 sq. mm on wall/truss with approved type of iron clamp etc. as required.
14Supplying & installing G.I. pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete.50.00mm, For "B" class pipe ISI marked (IS-1161- 68)
15Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.3 X 2.5 sq. mm.
16Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of "C" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-
17MCB SP 6Amp to 32Amp 10kA rating, Single pole
18MCB DP 6Amp to 32Amp 10kA rating, Double pole
19MCB TP 50Amp to 63Amp 10kA rating, For Triple pole
20MCB FP 50Amp to 63 Amp 10kA rating, Four pole
21Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal - magnetic release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2MCCB 25kA current rating - 125Amp & adjustable overload setting 80% -100% of In, adjustable short circuit setting 6-10 In 3 Pole
22Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only)
23MCB/Isolator SP/DP
24MCB/MCCB Isolator TP/TPN/FP
25Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & specification
26Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification
27Digital Ampere Metre with CTs with selector switch
28Digital Volt Metre with selector switch & HRC fuse
29Aluminium bus bar strips with PVC sleeves
30LED lamp indicator
31Supplying and fixing of cooler/A.C. M.S. angle iron stand including flat iron supports, grouting in wall if required, welding, painting with primer and two coat of superior quality paint complete.
32Supply and erection of approved make safe earthing electrode consisting pipe-in-pipe technology as per IS 3043-1987 made of corrosion free G.I. pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing in earth pit of minimum bore dia. 150mm size, as mentioned below :With 3 metre G.I. pipes having outer pipe dia of 50mm having 80-200 micron galvanizing, Inner pipe dia. of 25mm having 200-250 Micron galvanizing, connection terminal dia. of 12mm in nominal soil with 50 kg (two bag) back filling bentonite compound UL listed and confirm to relevant International/Indian standards around electrode upto ground level.
33Supply and installation of polycarbonate heavy duty pit cover tested for 5000Kg SWL for earth electrode at ground level size 300x300x155 mm with lockable lid.
34Providing and fixing 25mm X 5mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as required
35Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :-(Using modular accessories)
36Primary short point, Light point/fan points
37Primary medium point, Light point/fan points
38Primary long point, Light point/fan points
39Short point, 3 Pin 6 Amp socket outlet on separate board
40Medium point, 3 Pin 6 Amp socket outlet on separate board
41Long point, 3 Pin 6 Amp socket outlet on separate board
42Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.
43Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) of ISI marked suitable size etc. as required as per specification
442x2.5 Sq.mm
454x2.5 Sq.mm.
466x2.5 Sq.mm.
478x2.5 Sq.mm.
48Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-(Using modular accessories)
49Short point
50Medium point
51Long point
52Extra long -I
53Extra long -II
54Extra long -III
55Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp
56Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-
571Or 2 Module metal box
583 Module metal box
594 Module metal box
606 Module metal box
618/9 Module metal box
6212 Module metal box
6316 Module metal box
6418 Module metal box
65Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.
663 X 1.5 sq. mm.
673 X 2.5 sq. mm.
683 X 4.00 sq. mm.
69Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC conduit (MMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11)
706.0 sq. mm. cable, 3 Wire sub main
7110.0 sq. mm. cable, 3 Wire sub main
72Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)-12 Way double door IP 43 protection
73Supplying of approved make TPN MCB DB metal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator):4 Way (8+12)
74Labour charges for fixing sheet steel enclosures, MCB/MCCBDB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete :-27.11.1 to 27.11.7 ; 27.12.1 to 27.12.3 & 27.13.1
75Supply and fixing of approved make flush type step type electronic fan regulator including connection etc. as required on existing board100 Wat
76Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing boar100 Watt(2 module)
77Supplying and fixing of analog time switch for automatic ON - OFF street light of approved make in existing LT panel including connections etc. as required as per specification
78Supply and fixing Led tube rod comprising of LED tube with nonintegral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser.
79Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self-closing louvers of decorative PVC blades mounting square frame of approved make complete with all necessary material as required300mm RPM1300/1400
80Supplying, erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as required300mm sweep RPM 900 / 1400
81Supplying and fixing PVC casing and capping (double fold) ISI marked along with accessories on surface etc. as requiredmPVC casing and capping (double fold) 32 mm x 12mm
82Supplying and fixing PVC conduit ISI marked FRLS along withaccessories on surface etc. as required
83PVC conduit 20 mm. (MMS)
84PVC conduit 25 mm. (MMS)
85Supplying and fixing factory fabricated hot dip galvanized switch box for normal flush type accessories of minimum 1.2 mm thickness for up to 200mmx250mm size boxes and 1.6mm minimum thickness for higher size boxes, earth terminal stud with nut and washer, including 3 mm thick synthetic phenolic resin bonded laminated sheet conforming to grade P-I of IS:2036-1974 on surface/concealed including all necessary accessories, painting etc. as required as per specification:
86MS box 100 mm X 100 mm X 60mm
87MS box 200 mm X 150 mm X 60 mm
88MS box 180 mm X 100 mm X 60 mm
89MS box 125 mm X 300 mm X 60 mm
90MS box 200 mm X 250 mm X 60 mm
91MS box 250 mm X 300 mm X 60 mm
92MS box 300mm X 380 mm X 60 mm
93Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :-(Using flush type normal accessories)
94Primary short point, Light point/fan points
95Primary medium point, Light point/fan points
96Primary long point, Light point/fan points
97Secondary short point, (Light point/fan points) looping point
98Secondary medium point, (Light point/fan points) looping point
99Secondary medium point, (Light point/fan points) looping point
100Short point,Pin 6 Amp socket outlet on separate board
101Medium point,Pin 6 Amp socket outlet on separate board
102Long point,Pin 6 Amp socket outlet on separate board
103Short point, Call bell/buzzer points
104Medium point, Call bell/buzzer points
105Long point, Call bell/buzzer points
106Short point, Twin control light points
107Medium point, Twin control light points
108Long point, Twin control light points
109Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.
110Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) of ISI marked suitable size etc. as required as per specification
1112x2.5 Sq.mm.
1124x2.5 Sq.mm.
1136x2.5 Sq.mm.
1148x2.5 Sq.mm.
115Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-(Using flush type normal accessories)
116Short point
117Medium point
118Long point
119Extra long -I
120Extra long -II
121Extra long -III
122Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp
Disclaimer :