Providing Rates For Spv System Zp Bhandara- 1 Providing , Installation And Commissioning And Testing Solar Pump 2 Providing , Installing And Giving Test Of 0.5 Hp Spv Submersible Pump ( Dc ) Of Borewell ( 900 Watt Per Hp ) With All Necessary Attachments & ( 450 Watt Per Hp Pv Module ) As Peras Per Mnre Letter No 318 / 38 / 2018-Gcrtdtd 25 / 06 / 2020Asmotor Pumpset -0.5Hp, 450 W Submersible Pumpsetbrushless Dc Pump ( B.L.D.C. ) Dc Volt 90-300 V, Ac Volt 90-240 V, Inbuilt Controller 3 Providing , Installing And Giving Test Of 1.0 Hp Spv Submersible Pump ( Dc ) Of Borewell ( 900 Watt Per Hp ) With All Necessary Attachments & ( 900 Watt Per Hp Pv Module ) Asas Permnre Letter No 32 / 24 / 2020-Spv Division Dtd 18 / 08 / 2021 Motor Pumpset -1.0Hp, 900 W Submersible Pumpsetbrushless Dc Pump ( B.L.D.C. ) Dc Volt 90-300 V, Ac Volt 90-240 V, Inbuilt Controller 4 Providing , Installing And Giving Test Of 2.0 Hp Spv Submersible Pump ( Dc / Ac ) Of Borewell ( 900 Watt Per Hp ) With All Necessary Attachments & ( 900 Watt Per Hp Pv Module ) As Permnre Letter No 32 / 24 / 2020-Spv Division Dtd 18 / 08 / 2021As Per Motor Pumpset - 2.0Hp, 900 W Submersible Pumpsetbrushless Dc Pump ( B.L.D.C. ) Dc Volt 90-300 V, Ac Volt 90-240 V, Inbuilt Controller 5 Providing , Installing And Giving Test Of 3.0 Hp Spv Submersible Pump ( Dc / Ac ) Of Borewell ( 900 Watt Per Hp ) With All Necessary Attachments & ( 900 Watt Per Hp Pv Module ) As Permnre Letter No 32 / 24 / 2020-Spv Division Dtd 18 / 08 / 2021 As Permnre Technical Specification Annexure I And Ii 6 Providing , Installing And Giving Test Of 5.0 Hp Spv Submersible Pump ( Dc / Ac ) Of Borewell ( 900 Watt Per Hp ) With All Necessary Attachments & ( 900 Watt Per Hp Pv Module ) As Permnre Letter No 32 / 24 / 2020-Spv Division Dtd 18 / 08 / 2021As Permnre Technical Specification Annexure I And Ii . 7 Providing , Installing And Giving Test Of 7. 5 Hp Spv Submersible Pump ( Dc / Ac ) Of Borewell ( 900 Watt Per Hp ) With All Necessary Attachments & ( 900 Watt Per Hp Pv Module ) As Permnre Letter No 32 / 24 / 2020-Spv Division Dtd 18 / 08 / 2021 As Permnre Technical Specification Annexure I And Ii . 8 Providing , Installing And Giving Test Of 10.00 Hp Spv Submersible Pump ( Dc / Ac ) Of Borewell ( 900 Watt Per Hp ) With All Necessary Attachments & ( 900 Watt Per Hp Pv Module ) As Permnre Letter No 32 / 24 / 2020-Spv Division Dtd 18 / 08 / 2021As Permnre Technical Specification Annexure I And Ii . 9 A ) Installation And Ccommissioning Of 1.0 Hp Solar Pump Submersible Pumpsetbrushless Dc Pump With Inbuilt Controller ( B.L.D.C. ) Dc Volt 30-300 V, Ac Volt 90-240 V, Maximam Shut Off Head - 120 Meter Discharge -10000 Lit Per Day For 90 Meter Dynamic Head. 10 A ) Installation And Ccommissioning Of 2.0 Hp Solar Pump Submersible Pumpsetbrushless Dc Pump With Inbuilt Controller ( B.L.D.C. ) Dc Volt 30-300 V, Ac Volt 90-240 V, Maximam Shut Off Head - 120 Meter Discharge -15000 Lit Per Day For 90 Meter Dynamic Head. 11 A ) Installation And Ccommissioning Of 3.0 Hp Solar Pump Submersible Pumpsetbrushless Dc Pump With Inbuilt Controller ( B.L.D.C. ) Dc Volt 100-300 V, Ac Volt 90-240 V, Maximam Shut Off Head - 130 Meter Discharge -28000 Lit Per Day For 105 Meter Dynamic Head. 12 Hybrid Controllerfor 3.0 Hp Auto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Availableauto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Available With 5 Year Cmc 13 Hybrid Controllerfor 5.0 Hp Auto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Availableauto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Available With 5 Year Cmc 14 Hybrid Controllerfor7.50 Hp Auto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Availableauto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Available With 5 Year Cmc 15 Hybrid Controllerfor 10.0 Hp Auto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Availableauto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Available With 5 Year Cmc 16 Hybrid Controllerfor 12.50 Hp Auto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Availableauto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Available With 5 Year Cmc 17 Hybrid Controllerfor 15.00 Hp Auto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Availableauto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Available With 5 Year Cmc 18 Hybrid Controllerfor 20.00 Hp Auto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Availableauto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Available With 5 Year Cmc 19 Hybrid Controllerfor 25.00 Hp Auto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Availableauto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Available With 5 Year Cmc 20 Hybrid Controllerfor 30.00 Hp Auto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Availableauto Switching Between Grid And Solar Pump Can Be Operated On Both Solar And Grid, Solar Is Given First Preference. In Case Solar Power Generation Is Not Sufficient To Run Pump, Then Pump Operation Will Switch To Grid Unit Till Solar Power Is Available With 5 Year Cmc 21 Gps System Auto Start / Stop / Capability With Remote Tank Full Sensing And Control This Will Include:-Sensors Data Transmission To Server- Control Command To The Solar Water Pump.Controller Based Upon Tank Is Full Or Not.- Power Supply To The Data Collection / Transmission Unit.This Power Supply Needs To Be Batterybacked ( With Lithium Ferrous Phosphate Battery ) -Charge Controller For Battery Charging-12Wp Solar Panel5 Years Cmc And Maintenance 22 Supply Of Special Water Chamber S Per Gsda Year 2022-23 23 Supply Of Ss Nipple ( As Pergsda Year 2022-23 Approved 24 Supplying And Erecting Isi Mark Of Hdpe Pipe 32Mm Dia. Suitable For Pressure Of 6 Kg / Cm2 Connected To Submersible Cable ( Pwd Electrical Csr 2023-24 I 25 Supplying And Erecting Isi Mark Of Hdpe Pipe 50 Mm Dia. Suitable For Pressure Of 6 Kg / Cm2 Connected To Submersible Cable ( Pwd Electrical Csr 2023-24 I 26 Supply And Erecting Flat Flexible Submersible Cable With Copper Conductor Pvc Insulated And Pvc Sheathed3 Core 2.5 Sq. Mm As Per Is -694 Marked As Per _Pwd Electrical Dsr 2023-24 Item No Cb-12-4.-8Page. No.219 27 Supply And Erecting Flat Flexible Submersible Cable With Copper Conductor Pvc Insulated And Pvc Sheathed3 Core 4 Sq. Mm As Per Is -694 Marked As Per _Pwd Electrical Dsr 2021 Item No Cb-12-4.-8Page. No.219 28 Supply And Erecting Flat Flexible Submersible Cable With Copper Conductor Pvc Insulated And Pvc Sheathed3 Core 6 Sq. Mm As Per Is -694 Marked As Per _Pwd Electrical Dsr 2021 Item No Cb-12-4.-8Page. No.219 29 Extension Of Casing Pipe Is 1239 For Hand Pump Pedastal Assembly As Per Gsda Year 2022-23 Approved Rate 30 Repairing Existing Platform As Per Zp Bhandara Drillinge-Tender Year2022-23 31 Yield Test Charges Of Borewell As Pergsda Year2022-23 32 Redrilling Or Flushing Borewell 33 Water Tanker For Bore Well Acceptance Test 34 Removal & Installation Of Hand Pumpsas Pergsda Year 2022-23 35 Excavation For Foundation In Earth Soil Of All Types Sand, Gravel & Soft Murum, Including Removing The Excavated Material Up To A Distance Of 50 Meter & Stacking, Spreading As Directed, Normal Dewatering The Bed For Foundation & Excluding Back Filling Etc. Complete ( Mjp Dsr 2022-23 Sect. E- Item No -1 Page No.27 ) 36 Excavation For Foundation In Earth Soil Of All Types Sand, Gravel & Hard Murum, Including Removing The Excavated Material Up To A Distance Of 50 Meter & Stacking, Spreading As Directed, Normal Dewatering The Bed For Foundation & Excluding Back Filling Etc. Com. ( Mjp Dsr 2022-23 Sect. E-Item No 2 Page No. 27 ) 37 Excavation For Foundation In Earth Soil Of All Types Sand, Gravel & Hard Murumwith Boulder Including Removing The Excavated Material Up To A Distance Of 50 Meter & Stacking, Spreading As Directed, Normal Dewatering The Bed For Foundation & Excluding Back Filling Etc. Com. ( Mjp Dsr 2022-23 Sect. E-Item No 3 Page No. 27 ) 38 For Foundation / Pipe Trenches In Hardrock And Concrete Road By Chieselling , Wedging , Line Drilling By Mechanical Means Or By All Means Other Than Blasting Including Trimming And Levelling The Bed , Removing The Excavated Material Upto Distance Of 50M Beyond The Area Of Lift As Below , Stacking As Directed By Engineer In Charge, Normal Dewatering, Excluding Backfilling, Etc Complete By All Means. ( Bd-A- 1 / 259 ) { Mjp Dsr2022-23 Section E Item No 07 Page No.43 39 Providing Dry Trap / Granite / Quartzite / Gneiss Rubble Stone Soling In 15 Cm To 20 Cm Thick Layers Including Hand Packing & Compacting, Etc. Compl. ( Mjp Dsr 2022-23 Sect. E-Item 18Page No. 30 ) 40 Supplying And Laying Of Stone Aggregate 10 Mm To 20 Mm Nominal Gauge In The Foundation / Base Including Watering And Ramming Stone Aggregate 10 Mm Mjp Ssr 2023-24 Section A Sr. No. 49 Page No. 13 41 Providing And Laying Castin Situ / Ready Mix Cement Concrete In M-10 Of Trap / Granite / Quartzite / Gneiss Metal For Foundation And Bedding Including Bailing Out Water, Steelcentering, Formwork, Laying / Pumping, Compacting, Roughening The Mif Special Finish Is To Be Provided, Finishing If Required And Curing Complete, With Fully Automatic Micro Processor Based Plc With Scada Enable Dreversible Drum Type Mixer / Concrete Batch Mix Plant ( Panmixer ) Etc. Complete. With Fine Aggregate ( Crushed Sand Vsi Grade ) Pwd Ssr 2022-23 Sr. No. 832 Page No. 215 42 Supplying And Laying Of Washed River Sand Including Carriage To Site, Loading And Unloading, Laying In Base And Top Of Pit, Watering And Ramming Consolidating And Dressing Complete.Fine Sand ( From River Sand At Site ) Mjp Ssr 2021-22 Section M Sr. No. 10 E Page No. 230 43 Geotextile 400 Gsm ( Grams Per Sqm Membrane ) 44 Supply And Installation Of Co-Polymer Based Rainwater Harvesting Structure Including Supply Of Crosswave Cw-Hyq Of Size 494 Mm X 494 Mm X 220 Mm With Minimum Void Ratio Of 94.7% Having A Weigth Of 1.8 Kg And Specers Having Size Of 988 Mm X 240 Mm X 25 Mm Having A Weight Of 0.8 Kg Of Approved Make Including Deboarding Og Structure Inside The Tank, Lowering It As Per Diamention Including Covering It With Spacer Etc. Complete In All Respect 45 Making Perforation To Casing Pipe 1 Mtr. Height From The Base Of Moduler Filter 46 6 Pvc Cap As Per Gsda Rate 47 Providing & Laying In Situ Followingm150 C.C.Of Trap / Granite / Gneiss Metal For Foundation & Bedding Including Dewatering , Form Work , Compacting & Curing Finishing Etc. Complete ( Mjp Dsr 2022-23 Sect. G -Item No 1B Page No. 48 48 Column- Providing & Casting In Situ C.C. Of Trap Granite / Quartzite / Gneiss Metal Of Approved Qualityfor Rcc Work As Per Detailed Drawing & Design Or As Directed By Engineering In Charge Including Normal Drawing, Centering, Form Work, Compaction Finishing The Formed Surfaces With Cm 1 : 3 Sufficient Minimum Thickness To Give A Smooth & Even Surface Wherever Necessary Or Roughening If Special Finish Is To Be Provided & Curing Etc. Complete. Rcc M 250 ( Mjp Dsr 2022-23 Sect. G Item No 3C Page No. 49 ) 49 Horizontal Beam - Providing & Casting In Situ C.C. Of Trap Granite / Quartzite / Gneiss Metal Of Approved Qualityfor Rcc Work As Per Detailed Drawing & Design Or As Directed By Engineering In Charge Including Normal Drawing, Centering, Form Work, Compaction Finishing The Formed Surfaces With Cm 1 : 3 Sufficient Minimum Thickness To Give A Smooth & Even Surface Wherever Necessary Or Roughening If Special Finish Is To Be Provided & Curing Etc. Complete. Rcc M 250 ( Mjp Dsr 2022-23 Sect. G Item No 4C Page No.49 ) 50 Providing & Fixing In Position Steel Bar Reinforcement Of Various Dia. For Rcc Work Like Foundation, Beams, Column Etc As Per Detailed Drawing Design Including Cutting, Bending, Hooking The Bars Binding With Wires Or Track Welding & Supporting As Required Etc. Complete. For Solar ( Mjp Dsr 2022-23 Sect. G- Item No 8B Page No. 52 ) 51 Filling In Plinth & Floors Murum Bedding In Trencheswith Approved Murum From Excavated Materials From Foundation. 15 Cm To 20 Cm Layers Including Watering & Compaction Complete. ( Mjp Dsr 2022-23 Sect. G- Item No 8B Page No. 49 ) 52 Fillingin Plinth And Floor / Trenches With Contractor Murum For Bedding In 15Cm To 20Cm Layer Including Waterin And Compaction Complete ( Mjp Dsr 2022-23 Sect.E Item No 17 Page No. 42 ) 53 For Structureproviding Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc. As Per Detailed Design And Drawing Or As Directed By Engineer In Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Riveted Bolted Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc. Completebd-C-8 / 278 Mjp Dsr 2022-23 Sect. F Item No 6 54 Providing And Applying 2 Coats Of Alluminium Paint Of Approved Make To New Structural Steel Work In Buildings And Workshops Including Scaffolding If Necessary, Cleaning And Preparing The Surface ( Excluding Primer Coat ) Etc. Complete Pwd Dsr 2022-23 35.06 Bdo 4A 55 Providing And Applying Primer And One Coat Of Red Oxide Of Iron Paint Externally Including Cleaning The Surface Of Pipe With Steel Scrapers Wire Brushes And Metal Cleaning Solution Etc Completepwd Dsr 2022-23 35.07 Bdo 5 ( Sect. I ( Xvi ) Item No 18 Page No. 185 ) 282 56 For Structure ( Plus ) Providing And Applying Material & Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing As Per Market Rate 57 For Structure- Transporting Charges Of Vehicle Per Trip For Appox. 100 Km Leadincluding Loading Unloading & Stacking Charges. Mjp Dsr 2023-24 Sect. C Statement Iv Page No. 11 58 Providing & Erecting Chain Link Fencing 1.6 Mtr Height With G I Chain Linkof Size 50 X 50 Mm 8 Swg Thick And Fixed 75 Mm Above Gl Verticalm.S. Angle Of 40 X 40 X 6 Mm Size Embedded In Cc Block 1 :4: 8 Mix Of Size 450 X 450 X 670 Mm At 1.75 M Centre To Centre With Iron Bar 16 Mm Dia As A Hold Fast Including Welded Link With Angle Frame At 30 Cm Centre To Centre Nuts & Bolts & Horizontal Ms Angle At Top& Bottom Of 25 X 25 X5 Mm Size & Vertical Ms Flat 35 X 5 Mm & 25 X5 Mm Horizontal Including Cross Supports Of 40 X 40 X 6 Mmangle Both Sides At Every Corner In Cc With 3 Coat Of Oil Painting Etc Complete ( Pwd Ssr 2022-23 Bd-W-Item No.46.39 Page No 285 ) 59 Providing & Fixingm S Grill Gate Withframe Having Weight Of Gate 20 Kg / Sqm As Per The Detailed Drawing Including Hinges, Pivot Blocks Locking Arrangement Welding Riveting And Three Coats Of Oil Painting Of Approved Shed Etc. Complete. ( Pwd Ssr 2023-24 Bd-W- 6, Item No.23.09 60 Providingandfixingmildsteelgrillgatewithangleironframe65mmx65mmx10mmwithironbarsat150mmc / Canddiagonalflatsasperthedetaileddrawingincludinghinges, Pivotblocklockingarrangement, Weldingrivetingandoilpaintingofthreecoatsof Approved Shade Weight Of Gate 35 Kilogram / Smt. ( Pwd Ssr 2022-23 Bd-W- 6, Item No.44.10 61 Providing Second Class Burnt Brick Masonry With Conventional / I.S.Type Brick Since Mentmortar 1:6 In Foundation Sand Plinth Of Inner Walls / In Plinthe Xternal Walls Including Bailing Out Water Manually, Striking Joints On Unexposed Faces, Raking Out Joints On Exposed Faces And Watering Etc. Complete. Pwd Ssr 2022-23 Sr. No. 894 Page No. 242 I.No. 27.01 62 Providing And Laying Cast In Situ / Ready Mix Cement Concrete M-20 Of Trap / Granite / Quartzite / Gneiss Metal For Rcc Work In Foundations Like Rauft, Strip , Foundations, Etc. Comp..... Pwd Ssr 2022-23 Sr. No. 841 Page No. 219I.No. 25.11 63 Providing And Supplying In Standard Lengths Isi Mark Rigid Unplasticised Pvc Pipes Suitable For Potable Water With Solvent Cement Joints Including Cost Of Couplers, As Per Is Specification No. 4985 / 1988 Excluding Gst Levied By Goi And Gom In All Respect, Including Transportation, Freight Charges, Inspection Charges, Loading, Unloading, Conveyance To The Departmental Stores And Stacking The Same In Closed Shed Duly Protected From Sun Rays And Rains Including Cost Of Jointing Material I.E. Solvent Cement, Etc. Complete ( Selffit Type To Be Jointed With Cement Solvent ) . Mjp Ssr 2023-24 Sr.No. Ii 1 B Vii 64 Providing And Fixing Board Displaying Information Such As Name Of Work, Tender Cost, Name Of Contractor, Work Completion And Liability Period Etc Having Rectangular Shape Of 1.20M X 0.90M Size Made Out 18 Guage ( 1.25Mm ) Thick Mild Steel Sheet Painted With One Coats Of Azainc Chromate Stoving Primer And Two Coats Of Enamel Paint On Front Side And Grey Stove Enamel On Back Side And Border / Messages / Symbols Etc Size 35 X 35 X 3 Mm Frame With Property Cross Braced M.S Angles Of Size 35Mm X 35Mm X 3Mm Duly Painted Including Two M.S Angle Iron Posts Of Size 65Mm X 65 Mm X 6Mm, 3.65 M Long Painted With Alternate Black And White Bands Of 25 Cm Width Including All Fixtures Etc And Fixing The Boards In 1:4:8 Concrete Block On Size 60 Cm X 75 Cm Including Excavation, Refilling, Transporations And Labour Etc Complete.Pwd - Civil Csr :- 2022-23 I.No- 6.36 Pno.60 65 Providing And Fixing H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of Low Density Polyethyleneand Built Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity Above 100 To 1000 Liters As Per Is- 12701 As Per Pwd Ssr 2022-23Item No. 42.53 Reference Bdv Page No. 300 66 Providing And Fixing H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of Low Density Polyethyleneand Built Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity Above 1000 To 20, 000 Liters As Per Is- 12701 As Per Pwd Ssr 2022-23Item No. 42.54 Reference Bdv Page No. 300 67 Providing & Laying Of Isi Mark Gi Pipe Of Medium Class 25 Mm Dia. Including All Local & Central Taxes, Octroi, Inspection Charges, Transportation To Sores, Etc. Complete. With One End Coupling For Full Length Pipe. As Per Is 1239 / 2004 Mjp Dsr 2019-20 Sect.I ( Iv ) Item No 1 B-3 Page No.70 & Item No .2 B-3 Page No. 99. 68 Providing & Laying Of Isi Mark Gi Pipe Of Medium Class 50 Mm Dia. Including All Local & Central Taxes, Octroi, Inspection Charges, Transportation To Sores, Etc. Complete. With One End Coupling For Full Length Pipe. As Per Is 1239 / 2004 Mjp Dsr 2019-20 Sect.I ( Iv ) Item No 1 B-3 Page No.70 & Item No .2 B-3 Page No. 99. 69 Providing & Laying Of Isi Mark Gi Pipe Of Medium Class 65 Mm Dia. Including All Local & Central Taxes, Octroi, Inspection Charges, Transportation To Sores, Etc. Complete. With One End Coupling For Full Length Pipe. As Per Is 1239 / 2004 Mjp Dsr 2022-23Sect .I ( Iv ) Item No 1 B-3 Page No.70 & Item No .2 B-3 Page No. 99. 70 Providing And Fixing G.I Specials Such As Bend, Tee, Coupler As Mjp Elect. / Mechcsr 2022-23 Item No. Pw2-3-4-5, Pw1-7 Page No. 14, 1565Mm Dia Elbow 71 Providing And Fixing G.I Specials Such As Bend, Tee, Coupler As Mjp Elect. / Mechcsr 2022-23 Item No. Pw2-3-4-5, Pw1-7 Page No. 14, 15 25Mm Dia Elbow 72 Providing And Fixing G.I Specials Such As Bend, Tee, Coupler As Mjp Elect. / Mechcsr 2022-23 Item No. Pw2-3-4-5, Pw1-7 Page No. 14, 15 65Mm Dia Tee 73 Providing And Fixing G.I Specials Such As Bend, Tee, Coupler As Mjp Elect. / Mechcsr 2022-23 Item No. Pw2-3-4-5, Pw1-7 Page No. 14, 15 25 Mm Dia Tee 74 Providing And Fixing G.I Specials Such As Bend, Tee, Coupler As Mjp Elect. / Mechcsr 2022-23 Item No. Pw2-3-4-5, Pw1-7 Page No. 14, 15 65 Mm Dia Coupler / Socket 75 Providing And Fixing G.I Specials Such As Bend, Tee, Coupler As Mjp Elect. / Mechcsr 2022-23 Item No. Pw2-3-4-5, Pw1-7 Page No. 14, 15 25 Mm Dia Coupler / Socket 76 Providing And Fixing G.I Specials Such As Bend, Tee, Coupler As Mjp Elect. / Mechcsr 2022-23 Item No. Pw2-3-4-5, Pw1-7 Page No. 14, 15 G.I. Union Duty 25Mm 77 Providing And Fixing G.I Specials Such As Bend, Tee, Coupler As Mjp Elect. / Mechcsr 2022-23 Item No. Pw2-3-4-5, Pw1-7 Page No. 14, 15 G.I. Union Duty 65Mm 78 Lowering Laying And Jointing G. I Pipes And Specialsof Following Class And Dia Including Conveyence From Store To Site Of Work. Medium Classmjp Dsr2022-23 Sect. 1-4 Item No.- 2-B P.No.102 A ) 25 Mm Dia. 79 Lowering Laying And Jointing G. I Pipes And Specialsof Following Class And Dia Including Conveyence From Store To Site Of Work. Medium Classmjp Dsr2022-23 Sect. 1-4 Item No.- 2-B P.No.102 A ) 50 Mm Dia. 80 Lowering Laying And Jointing G. I Pipes And Specialsof Following Class And Dia Including Conveyence From Store To Site Of Work. Medium Classmjp Dsr2022-23 Sect. 1-4 Item No.- 2-B P.No.102 B ) 65 Mm Dia. 81 Providing And Supplying In Standard Lengths Isi Mark Rigid Unplasticised Pvc Pipes Suitable For Potable Water With Solvent Cement Joint Including Cost Of Coupler As Per Isi Specification No. 49856 / 1998 Excluding Gst Levied By Goi And Gom In All Respect , Including Transportation , Freight Charges , Inspection Charges Loading, Unloading , Conveyance To The Department Stores And Stacking The Same In Closed Shed Duly Protected From Sun Rays And Rains Including Cost Of Jointing Material I.E. Solvent Cement Etc ( Self Fit Type To Be Jointed With Cement Solvent ) Working Pressure 4 Kg / Sq.Cm. 75Mm Dia 82 Providing And Supplying In Standard Lengths Isi Mark Rigid Unplasticised Pvc Pipes Suitable For Potable Water With Solvent Cement Joint Including Cost Of Coupler As Per Isi Specification No. 49856 / 1998 Excluding Gst Levied By Goi And Gom In All Respect , Including Transportation , Freight Charges , Inspection Charges Loading, Unloading , Conveyance To The Department Stores And Stacking The Same In Closed Shed Duly Protected From Sun Rays And Rains Including Cost Of Jointing Material I.E. Solvent Cement Etc ( Self Fit Type To Be Jointed With Cement Solvent ) 75 Mm Dia. 6 Kg / Sq. Cm 83 Providing And Supplying In Standard Lengths Isi Mark Rigid Unplasticised Pvc Pipes Suitable For Potable Water With Solvent Cement Joint Including Cost Of Coupler As Per Isi Specification No. 49856 / 1998 Excluding Gst Levied By Goi And Gom In All Respect , Including Transportation , Freight Charges , Inspection Charges Loading, Unloading , Conveyance To The Department Stores And Stacking The Same In Closed Shed Duly Protected From Sun Rays And Rains Including Cost Of Jointing Material I.E. Solvent Cement Etc ( Self Fit Type To Be Jointed With Cement Solvent ) 110 Mm Dia. 6 Kg / Sq. Cm 84 Providing And Supplying In Standard Lengths Isi Mark Rigid Unplasticised Pvc Pipes Suitable For Potable Water With Solvent Cement Joint Including Cost Of Coupler As Per Isi Specification No. 49856 / 1998 Excluding Gst Levied By Goi And Gom In All Respect , Including Transportation , Freight Charges , Inspection Charges Loading, Unloading , Conveyance To The Department Stores And Stacking The Same In Closed Shed Duly Protected From Sun Rays And Rains Including Cost Of Jointing Material I.E. Solvent Cement Etc ( Self Fit Type To Be Jointed With Cement Solvent ) 160 Mm Dia. 6 Kg / Sq. Cm 85 Providing And Fixing P.V.C. Rain Water Pipes Of 160Mm Outer Diameter And Having Wall Thickness Of 2.2 To 2.7 Mm Confirming To I.S. 13592-1992 Including Proper Rainwater Receiving Recess With P.V.C. Plug, Bend, Necessary Fittings, Such As, Offsets, Shoes, Inluding Fixing The Pipe On Wall Using Approved Wooden Cleats Projecting 25Mm To 40Mm From Face Of Wall A Fixing With Clips Of Approved Quality And One Number , Filing The Joint Using Rubber Gasket With Solvent Cement And Properly Resting The Shoe Of Pipes On C.C. Or Masonry Blocks, Including Necessary Scaffolding And Maintenance For 3 Yrs For Any Leakages Or Dislocations Of Pipes. All The P.V.C. Fittings And Additional 2 Piece Socket Clips Shall Be Got Approved From Engineer In Charge Etc. Complete. Pwd Ssr 2022-23 Sr. No.1461Page No. 353 86 Providing And Fixing Of Cgwp / Griha Approved Pure Rain Filter 700 Mm Dia With 300 Mm Dia Inlet And Outlet To Accumulate Storm Water Having Deselting Suspended Solid Catch Made Out Of Frp ( Fibre Reinforced Polymer ) With Stainless Steel 304 Grade Strainers, Having Steel Bucket Of 600 Micron Capable Of Eliminating Finer Particulate Matter Upto 160 Micron Filtration Made Of Stainless Steel Net With Long Fibre Foam Of 25 Mm Thickness, Blue Colour, Filtration Capacity 40-80 Kilolitres ( Including 1 Nos. Of Extension Of 600 Mm Depth ) ( Market Rate ) 87 Lowering Laying And Jointing With P.V.C. Pipe And Specialsof Following Class And Dia Including Conveyence From Store To Site Of Work. Including Cost Of Labour , Material , Except Cement Solvent , Rubber Ring As Per Is Code Etc, Completeworking Pressure Of75 Mm Dia. 4 Kg / Sq. Cm 88 Lowering Laying And Jointing With P.V.C. Pipe And Specialsof Following Class And Dia Including Conveyence From Store To Site Of Work. Including Cost Of Labour , Material , Except Cement Solvent , Rubber Ring As Per Is Code Etc, Completeworking Pressure Of 6 Kg / Sq.Cm. 75 Mm Dia. 6 Kg / Sq. Cm 89 15 Mm Dia Service Water Tapconnection For Distributionnetwok Of Mdpe / Upvcpipe Without Road Crossing As Per Mjp Ssr 2023-24 Sec - H, Item No -17 Apage No. 65 90 15 Mmdia Service Water Tapconnection For Distributionnetwok Of Mdpe / Upvcpipe With Road Crossing Asper Mjp Ssr 2023-24 Sec - H, Item No -17 Apage No. 65 91 Providing And Fixing Screw Down Required Dia Wheel Stop Tap Of Brass Including Necessary Socket , Union Nuts , Testing Etc Complete ( Prior Approval Of Sample And Brand By Executive Engineerids Necessary Before Use ) Type Of 65 Mm Dia ( As Per Pwd Ssr 2022-23 Item No 41.49 - Bdv-9A Page No 259 ) 92 Providing And Fixing Screw Down Required Dia Wheel Stop Tap Of Brass Including Necessary Socket , Union Nuts , Testing Etc Complete ( Prior Approval Of Sample And Brand By Executive Engineerids Necessary Before Use ) Type Of 40 Mm Dia ( As Per Pwd Ssr 2022-23 Item No 41.49 - Bdv-9A Page No 259 ) 93 Providing And Fixing Screw Down Required Dia Wheel Stop Tap Of Brass Including Necessary Socket , Union Nuts , Testing Etc Complete ( Prior Approval Of Sample And Brand By Executive Engineerids Necessary Before Use ) Type Of 25 Mm Dia ( As Per Pwd Ssr 2022-23 Item No 41.45 - Bdv-9A Page No 346 ) 94 Providing And Fixing Screw Down Required Dia Wheel Stop Tap Of Brass Including Necessary Socket , Union Nuts , Testing Etc Complete ( Prior Approval Of Sample And Brand By Executive Engineerids Necessary Before Use ) Type Of 50 Mm Dia ( As Per Pwd Ssr 2022-23 Item No 41.48 - Bdv-9A Page No 346 ) 95 Providing And Erecting C.I.D.F. Sluice Valve With Joint To Pipe Workwithout By Pass Arrangementpn 1.6 , 65Mm Dia 96 Providing And Erecting C.I.D.F. Sluice Valve With Joint To Pipe Work Without By Pass Arrangementpn 1.6 , 80Mm Dia 97 Lowering Laying And Jointing In Position Followingc.I.D.F. Sluice Valve, Reflux Valve, I.E. All Labour , Jointing Material I.E. Nut Bolts And Giving Satisfactory Testing 65Mm Dia 98 Lowering Laying And Jointing In Position Followingc.I.D.F. Sluice Valve, Reflux Valve, I.E. All Labour , Jointing Material I.E. Nut Bolts And Giving Satisfactory Testing 80Mm Dia 99 Supplying And Erecting Non Return Valve 25 Mm Diameter In Position Made Of Gun Metalas Per Pwd Electricalcsr 2022-23 Specification No. Cw-Plb / Gp 16-6-21 Page No 247 100 Supplying And Erecting Non Return Valve 40 Mm Diameter In Position Made Of Gun Metalas Per Pwd Electricalcsr 2022-23 Specification No. Cw-Plb / Gp 16-6-21 Page No 247 101 Supplying And Erecting Non Return Valve50 Mm Diameter In Position Made Of Gun Metalas Per Pwd Electricalcsr 2022-23 Specification No. Cw-Plb / Gp 16-6-21 Page No 247 102 Supplying And Erecting Non Return Valve 65 Mm Diameter In Position Made Of Gun Metalas Per Pwd Electricalcsr 2022-23 Specification No. Cw-Plb / Gp 16-6-21 Page No 247 103 Supplying & Erecting Float Sensor Switch For Water Level Controller Working On 250V & Rated Current 8A, With 2 Mtr. Wire & High Quality Of Wire & Plasticbody. 104 Supplying & Erecting Water Level Controller 230 / 415 V.A.C, Four Wayfor Under Ground & Overhead Tank Operation. Pwd Csr ( Ele 2022-23 Item No. 12-4-15 Page No 105 Supplying & Erecting Mains With 2X1.5 Sq.Mm. And Earth Wire 1.5 Sq.Mmfr Pvc Copper Wire, In Rigid Pvc Conduit Min.20Mm Dia, As Per Pwd Csr ( Ele 2020-21 : Wg-Ma / Pc, Item No 1-6-1 Page No 08 106 Hydraulic Testing Of Pvc Pipeline To Specified Pressure Including Cost To Fall Materials And Labour And Water For Testing For Specified Length Including Cutting, Placing End Cap Making Arrangementfor Filling Safe Water Using Reciprocating Type Pumps Which Should Be Able To Provide Specified Test Pressure Gauges And Other Necessary Equipments, Labour, Operation Charges, Etc. Required For Testing. The Rate Under This Item Shall Also Include Cost To For Testing, If Necessary And Reinstating To Original Position. 75Mm Dia Pvc 6 Kg / Cm^2 107 Commissioning Running And Maintaining The Scheme To Quantities, Rated Capacity, Including Manning Necessary Personnel Such As Operator, Valve Man Etc As Per Requirement Of The Scheme And Who Should Also Administer Chemical Dose For A Period Of 1 Year For Individual Scheme And 1 Years For Regional Scheme, Together With Training Of Persons Spared By Mjp / Local Body And Handing Over The Scheme To Local Body After Completion Of The Above Period As Directed By Engineer In Chargeetc. Complete. 108 Installation Commissioning And Trialrun Of Min 3 Monthafter Successfull Installationofsolar Energy Based R.O. Plus Uvof 25 Lph Capacity Warrantee Of 1 Year From Date Of Successful Commissioning , 109 Installation Commissioning And Trialrun Of Min 3 Monthafter Successfull Installationof Solar Energy Based R.O. Plus Uvof 50 Lph Capacity Warrantee Of 1 Year From Date Of Supply, 110 Installation Commissioning And Trialrun Of Min 3 Monthafter Successfull Installationofsolar Energy Based R.O. Plus Uvof 100 Lph Capacity Warrantee Of 1 Year From Date Of Successful Commissioning , 111 Installation Commissioning And Trialrun Of Min 3 Monthafter Successfull Installationof Solar Energy Based R.O. Plus Uvof 250 Lph Capacity Warrantee Of 1 Year From Date Of Successful Commissioning , 112 Installation Commissioning And Trialrun Of Min 3 Monthafter Successfull Installationofsolar Energy Based R.O. Plus Uvof 500 Lph Capacity Warrantee Of 1 Year From Date Of Successful Commissioning , 113 Installation Commissioning And Trialrun Of Min 3 Monthafter Successfull Installationof Solar Energy Based R.O. Plus Uvof 1000 Lph Capacity Warrantee Of 1 Year From Date Of Successful Commissioning , 114 Dismantleexisting Structure And Removal Existing Water Storage Tank Of 5000 Lit Capacity And Again Placed Tank On G.I. Structure After Installation , Including Labour , Machinary And Required Tool 115 Construction And Providing Two Tap Standpost 116 Rwh - Shallow Percolation Pit Providing, Constructing 2.0M Deep Shallow Depth Percolation Pit Comprising Of 1.0M Dia Pre-Cast Rcc Rings, 300Mm Thick Side Filling Around Outside Of Rcc Rings ( Annular Space ) With 40Mm Size Boulders Including Filling Of Percolation Pit Up To 0.5M Depth ( From Bottom Up ) With 25-75Mm Clean Washed Gravels Followed By 0.5M Depth Of 10-25Mm Of Clean Washed Stones Followed By 0.5M Of Washed River Fine Aggregate ( Natural Sand / Crushed Sand Vsi Grade Finely Washed Etc. ) Including Netlon Mesh Between Each Gravel / Fine Aggregate ( Natural Sand / Crushed Sand Vsi Grade Finely Washed Etc. ) Media Layer Including Covering With Rcc Slab, Manhole Frame & Cover, Pvc Rungs Etc. Including Arrangement For Inlet & Outlet Pipe, Excavation & Backfilling As Shown In The Drawing. The Rate Shall Be Inclusive Of All Labour, Material, Wastage, Scaffolding, Transportation, Taxes, Including All Leads, Lifts At All Levels. All Material Should Be Of Approved Make. All Works Complete As Per The Drawing, Technical Specification And Direction Of The Engineer In Charge As Per Pwd Ssr2022-23 Item No. 48.46 Page Nos 302 117 Supplying , Installing , Testing And Commissioning Of Solar Led Mini High Mast20 W X 5 Nos . Led Lumanaries , 2 Nosx 150 Ah 12 V Lithium Battery, Min. 400 Wpspv Modules Mounted On Gi Octagonal Pole With Bottom Of 130 Mm A / F Top 70Mm A / F 6 Mtr Height Along With Bracket , Foundation Earthing And Necessaries Accessories , Water Proof Battery Box, Suitable Solar Inverter , Timer Setting Arrangement, Gi / Powder Coated Module Structure , With First 6 Hrs Full Intensity Light Output And Following 6 Hrs With Half Intensity Light Output Along With Solar And Local Electrical Power Supplyarrangement, Wave Solar Powersupply Charging Fascility Complete. With 5 Year Warrantee ( 1. Solar Comprising Mono Crystalline Photovoltaic Cell Of The Same Capacity.2. Inclusive Of Total System Commissing, Istalling , Tramsportation , Insurance With 5 Years Of Amc / Cmc Specification Nos.As Per Pwdelectrical Mech Csr2022-23 Item No 4-3-14 118 Supplying, Installing, Testing And Commissioning Solar Streetlight Pole Comprising Of 9 W Led Fitting, 12V 18Ahmaintenance Free Lithium Battery, Min. 40 Wp Spv Module, Mspowder Coated Battery Box Weather Proof, Mounted On 75 / 80Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete.Specification No. Esd-Sol-Stl ( With 5 Years Warrantee )