Military Engineer Services-MES has published Tender For Repair And Maintenance Of Split Window Acs Ac Plant And Cooling Appliances Refrigerators And Misc Work At Palampur Mil Stn. Submission Date for this Tender is 19-03-2024. Air Conditioner Tenders in palampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42347805
Corrigendum : Tender For Repair And Maintenance Of Split Window Acs Ac Plant And Cooling Appliances Refrigerators And Misc Work At Palampur Mil Stn
Open Tender
Indian
Himachal Pradesh
palampur
19-03-2024

Tender Details

Repair And Maintenance Of Split Window Acs Ac Plant And Cooling Appliances Refrigerators And Misc Work At Palampur Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR AND MAINTENANCE OF SPLIT/WINDOW AC"s, AC PLANT AND COOLING APPLIANCES, REFRIGERATORS AND MISC WORK AT PALAMPUR MIL STN
Sl. No. Item Description
1M&L in replacement of unserviceable hermiticallysealed compressor of refrigerator 310/285 litres capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage,gas charging, complete and testing after completion of work at MES Store yard for satisfactory function complete all as specified and directed. Note:- (i)The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii)The new unit will be purchased from authorized dealer.
2M&L in replacement of unserviceable hermiticallysealed compressor of refrigerator 165/180/196litres capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectification of leakage,gas charging, complete and testing after completion of work at MES Store yard for satisfactory function complete all as specified and directed. Note:- (i)The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii)The new unit will be purchased from authorized dealer..
3S&F in repairs relay suitable for 286/310 litres capacity refrigerator complete all as specified and directed. Make:- Renutrol/Shriram/Anpurna/klixon or equivalent make as approved by GE.
4S&F in repairs relay suitable for 165 litres capacity refrigerator complete all as specified and directed. Make:- Renutrol/Shriram/Anpurna/klixon or equivalent make as approved by GE.
5S&F in repairs thermostat automatic `R"frost with knob suitable for 165/286/310 litres capacity refrigerator complete all as specified and directed. Make :-Anpurna/Indofos or equivalent make as approved by GE.
6S&F in repairsfreezer assembly complete with screw, jointing of tubes etc. and testing of capacity 286/310 litres refrigerator complete all as specified and directed.
7S&F in repairs freezer assemblycomplete with screw, jointing of tubes etc. and testing of capacity 165/175 litres refrigerator complete all as specified and directed.
8S&F in replacement of condenser coil unit with necessary fixing arrangements and testing suitable for 285/310 Liters capacity refrigerator complete all as specified and directed.
9S&F in replacement of condenser coil unit with necessary fixing arrangements and testing suitable for 165/170/180 Liters capacity refrigerator complete all as specified and directed.
10M&L flushing out system , checking and rectification of leakages if any and make it serviceablegas charging with refrigerant R-12/R-134A or as per actual requirement, oil charging complete in refrigerator of capacity 286/310 litres complete all as directed & with entire satisfaction of Engineer-in-Charge. Note:-Gas charging will be measured and paid under relevant item separately.
11M&L flushing out system , checking and rectification of leakages if any and make it serviceable gas charging with refrigerant R-12/R-134 A or as per actual requirement, oil charging complete in refrigerator of capacity 165/180 litres complete all as directed & with entire satisfaction of Engineer-in-Charge. Note:-Gas charging will be measure and paid under relevant item separately.
12Supply and charging of freon gas R-134/R-12 for refrigerator,deep freezercomplete all as specified and directed .
13S&Fin replacement of door gasket of best quality suitablefor up to 286 liters capacity refrigerator complete as per manufacturer"s instruction and as directed by Engineer-in-Charge.
14S&Fin replacement of door handle of best quality suitablefor up to 286 liters capacity refrigerator complete as per manufacturer"s instruction and as directed by Engineer-in-Charge.
15S&Fin replacement of bottle self of best quality suitablefor up to 286 liters capacity refrigerator complete as per manufacturer"s instruction and as directed by Engineer-in-Charge.
16S&Fin replacement of vegatable tray of best quality suitablefor up to 190/286 liters capacity refrigerator complete as per manufacturer"s instruction and as directed by Engineer-in-Charge.
17S&Fin replacement ofcabinate shelves of best quality suitablefor up to 286 liters capacity refrigerator complete as per manufacturer"s instruction and as directed by Engineer-in-Charge.
18S&Fin replacement ofcrisper glass of best quality suitablefor up to 286 liters capacity refrigerator completeas per manufacturer"s instruction and as directed by Engineer-in-Charge.
19S&Fin replacement ofdoor lock of best quality suitablefor up to 286 liters capacity refrigerator completeas per manufacturer"s instruction and as directed by Engineer-in-Charge.
20Repair to unserviceable/burnt stablizer of 0.5KVA to 1 KVA capacity complete including replacement of knobs, rewinding of burnt transformer etc complete all as specified and directed. Note : The other item like time delay relay, over load relay etc shall be measured and paid seprately as supply only.
21Supply only time delay relay 500 volts complete all as specified and directed.
22Supply only over load relay 25-40 Amp complete all as specified and directed.
23M&L servicing /overhauling of Split/Window/Tower type Ac unit of capacity1.5/2.0/2.5 Ton including painting to outer cover and components with two coats of synthetic enameled paintof colour as directed) complete including following:- (a) Cleaning and descaling of condensing unit and cooling coil with caustic soda mixed water and air blower and taking out all dirt /sludge etc. all as directed by EIC. (b) Greasing / oiling of blower fan motor. (c)Chargingthe gas as required to full fill the rated cooling effect. (d) Change the defective parts of AC likecondensar fan motor, fan balt, blower/relay/PCB card/thermostate/copper pipe/heating assembly/capacitor/ etc, if change during servicing then same shall be paid as supply only.
24M&L in replacement of unserviceable5 Star Hermetically cut sealed compressor of Tower type ACs 2.5 TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i)The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii)The new compressor unit will be purchased from authorized dealers only as perexisting make and model
25M&L in replacement of unserviceable5 Star Hermetically cut sealed compressor of Split ACs 2.0 TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning complete all as specified and directed. NOTE:- (i)The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii)The new compressor unit will be purchased from authorized dealers only as perexisting make and model
26M&L in replacement of unserviceable5 Star Hermetically cut sealed compressor of Split ACs 1.5 TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, gas charging complete and testing after completion of work at MES store yard for satisfactory functioning complete all as specified and directed. NOTE:- (i)The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii)The new compressor unit will be purchased from authorized dealers only as perexisting make and model
27S&F in replacement to swing blade motor suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type complete all as specified and directed. Note: Sample needs to be verified, before using at site. Make:- LG/Voltas/Samsung or equivalent make as approved by GE.
28S&F in replacement to Indoor AC Blower fan suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type complete all as specified and directed. Note: Sample needs to be verified, before using at site. Make:- LG/Voltas/Samsung or equivalent make as approved by GE.
29S&F in replacement to Indoor AC Blower motor suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type complete all as specified and directed. Note: Sample needs to be verified, before using at site. Make:- LG/Voltas/Samsung or equivalent make as approved by GE.
30S&F in replacement to Outdoor Fan motor suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type complete all as specified and directed. Note: Sample needs to be verified, before using at site. Make:- LG/Voltas/Samsung or equivalent make as approved by GE.
31S&F in replacement to Outdoor Fan motor Capacitor suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type complete all as specified and directed. Note: Sample needs to be verified, before using at site. Make:- LG/Voltas/Samsung or equivalent make as approved by GE.
32S&F in replacement to Indoor Cooling Coil suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type complete all as specified and directed. Note: Sample needs to be verified, before using at site. Make:- LG/Voltas/Samsung or equivalent make as approved by GE.
33S&F in replacement to outdoor Condensor Coil suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type complete all as specified and directed.. Note: Sample needs to be verified, before using at site. Make:- LG/Voltas/Samsung or equivalent make as approved by GE.
34S&F in repair to AC Indoor unit Main Board (PCB Card) with display unit suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type complete all as specified and directed. Note: Sample needs to be verified, before using at site. Make:- LG/Voltas/Samsung or equivalent make as approved by GE.
35S&F in replacement AC Indoor unit drain water pipe suitable for 1.5/2.0 TR Split AC/ Tower AC of any make and of any type, and also making good the entire surface complete all as specified and directed. Note: Sample needs to be verified, before using at site. Make:- Prince/Supreme or equivalent make as approved by GE.
36S&F in replacement copper pipe of size 1/4 " complete with 13mm insulation from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
37S&F in replacement copper pipe of size 1/2 " complete with 13mm insulation from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
38S&F in replacement copper pipe of size 3/8 " complete with 13mm insulation from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
39S&F in replacement copper pipe of size 5/8 " complete with 13mm insulation from outdoor unit to indoor unit including soldering and brazing complete all as specified and directed.
40S&F in repairs heating assy for Air Conditioner capacity1.5/2 Ton complete all as specified and directed.
41S&F in repairs indoorAir Filter for Air Conditioner of capacity 1.5/ 2T complete all as specified and directed.
42S&F in repairsrunning capacitor clip type of cap. 36 MFD, 240 volts 50 cycles for window type/Split typeair conditioner 1.5 Ton capacity complete all as specified and directed. Make:- Escop/Kell/Tesla/Sharda or equivalent make as approved by GE.
43S&F in repairsstarting capacitor clip type of cap. 80-100 MFD,440 volts 50 Hz for window type /Split type air conditioner 1.5 ton capacity complete all as specified and directed. Make:- Kell/Tesla/Sharda/Epcosor equivalent make as approved by GE.
44S&F in repairsrunning capacitor clip type of cap. 45MFD, 240 volts 50 cycles for Split /window type air conditioner 2 Ton Capacity complete all as specified and directed. Make:- Epcos/Kell/Tesla/Sharda or equivalent make as approved by GE.
45S&F in repairs starting capacitor clip type of cap. 100-120 MFD,440 volts 50 Hz for window type/split typeair conditioner 2 Ton capacity complete all as specified and directed. Make:- Kell/Tesla/Sharda/Epcos or equivalent make as approved by GE.
46S&F in repairscapacitor 4 Mfd in split type AC complete all as specified and directed.
47S&F in repairs capacitor 6 MFD in split type AC complete all as specified and directed. Make: Epcos/texla or equivalent make as approved by GE.
48S&F in repairs capacitor 2.5 MFD in split type AC complete all as specified and directed. Make:Epcos/texla or equivalent make as approved by GE.
49S&F in repairs valve of any size (1/2 ", 1/4 " 3/8"and 5/8 ")for split type of capacity 1.5/2/2.5 TRin split type AC complete all as specified and directed.
50S&F in replacement sheet metal enclosures with socket, plug top and MCBs single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 32 Amps240 Volts complete all as specified and directed.
51S&F in repairs thermostat switch suitable for 2 ton /1.5 ton capacity air Conditioner complete all as specified and directed.
52S&F in repairs relay suitable for 2 ton/1.5 ton capacity Air Conditioner as per sample complete all as specified & directed.
53S&F in replacement to stablizer of 1 KVA to 2 KVA capacity complete all as specified and directed.
54S&F in replacement to stablizer of 3 KVA to 5 KVA capacity complete all as specified and directed.
55S&F in repairover load relay 25-40 Amp complete all as specified and directed.
56Supply only RefrigerantR-12/134/410A complete filled in cylinderin all respect complete all as specified and directed.
57Supply only RefrigerantR-22 completefilled in cylinder complete in all respect complete all as specified and directed.
58Supply only 10 KG Cylinder complete with valve for refrigerant filling complete in all respect complete all as specified and directed.
59Supply only nitrogen gas for testing of leakage in copper pipes filled in cylinder complete all as specified and directed.
60Supply only Butane gas Cans of weight 250gms complete all as specified and directed.
61Supply only Manual butane Torch Steel High Power Butane/LPG Gas Blow Torch forBrazing complete all as specified and directed.
62Supplying and re-charging of refrigerant Gas R-22 / R-134Ain AC Plant after detection of leakage & rectification of same in the system by using Carbon Di-oxide Gas and flushing the complete system thoroughly with Nitrogen gas, complete all as specified and directed. Note:- (i) Gas shall be brought by the contractor at Site from authorized Dealer/Manufacturers in sealed cylinders of standard packingsand re-filling shall be done in the presence of rep of Deptt. The empty cylinders after using the gas brought shall be returned to the contractor for payment purpose, only gas to the required extent used for charging shall be considered. (ii) The unit rate inserted is being to be inclusive of the cost of nitrogen gas used for leakage test and pressure test prior to filling/ charging of gas R-22 / R-314A
63Supply and re chargingcompressor oil (Non-freezing) in AC plant, complete all as specified and directed. Make:- SHEETAL/ CALTEX/ ZED PLUS or equivalent make as approved by GE. NOTE:- Compressor oil shall be brought by the contractor in sealed barrels.
64Descaling the condenser by recommended chemical cleaning agent by soaking method, disconnection condenser from the system by taking out nuts bolts, studs 2 Nos valves and MS/GI pipe line form both sides cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4mm thick for following capacities of condensers suitable for AC plant capacities installed as indicated below, complete all as specified and directed.
65Descaling the chiller by recommended chemical cleaning agent by soaking method, disconnection condenser from the system by taking out nuts bolts, studs 2 Nos valves and MS/GI pipe line form both sides cover, cleaning each tube with nylon brush, flushing with alkaline solution connecting back both side cover including replacing leather gasket 4mm thick for following capacities of condensers suitable for AC plant capacities installed as indicated below, complete all as specified and directed.
66Dismantling of worn out part of FRP cooling tower of capacity 60 TR,cleaning of water tanks and body of cooling tower to make the cooling tower functional and serviceable in all respect including rectification of minor leakages from the cooling tower with M Seal adhesive, complete all as specified and directed.
67S&F side cover jalli for cooling tower for capacity 60 TR in replacement as per existing size and pattern, complete all as specified and directed.
68Taking out unserviceable wiring of panel/control system of AC Plant micro processor panel , rewiring the same with new suitable capacity of copper conductor PV insulated wire and making connection to make the control/ interlocking systemfunctional, complete all as specified and directed.
69Repair to heating unitof AC plant and change the burnt panel incl complete wiring and change the unserviceable power contactor, copper wore, Power relay, Phase indicator LED type lamp, amp meter, voltmeter and electric control panel complete all as specified and directed.
70S&F top protector cover to the CT fan motor at the top of the coolingtower made of GI sheet20 SWG, conical shape including flat iron of required size complete to protect the CT fan motor form rain water, complete all as specified and directed.
71S&F metallic viscose filter in replacement made out of GI wire mesh interspaced with two crimp layers and three flat layers and housed in 2" deep metal frame efficiency 65% as per existing size and pattern for AC Plant air handling unit at signal centre complex, complete all as specified and directed.
72S&F water pressure gauge 100 mm dia range 0-100 Lbs/Sq inch , complete all as specified and directed.
73S&F suction pressure gauge suitable for range30 to 150 Lbs/Sq inch, complete all as specified and directed.
74S&F discharge pressure gauge suitable for range 0-300 Lbs/Sq inch, complete all as specified and directed.
75S&F air grills made out of GI sheet as per existing size and pattern complete with necessary nuts, bolts, clamps and MS frame made out of angle iron of required size damper for opening and closing of grills, complete all as specified and directed.
76S&F cast iron butterfly valve of size 150 mm dia (ISI marked)complete all as specified and directed.
77S&F cast iron butterfly valve of size 100 mm dia (ISI marked) complete all as specified and directed.
78S&F cast iron butterfly valve of size 80 mm dia (ISI marked) complete all as specified and directed.
79S&F cast iron balancing valve of size 80 mm dia (ISI Mark), complete all as specified and directed.
80S&F cast iron "Y" Strainer of size 80 mm dia (ISI Mark) complete all as specified and directed.
81S&F in replacement 80mm, 3 way motorised valve with actuator motor complete in all respect. Make: Honeywell/ Siemens/Emerson or equivalent make as approved by GE.
82S&F bearing set (set of Bearings) (ISI marked) for AC Plant of capacity 60 TR complete all as specified and directed.
83S&F gasket set for AC plant complete all as specified and directed.
84S&F filter for AC plant complete all as specified and directed.
85S&F power contactor of rating 25 amp 4 pole complete all as specified and directed.
86Disconnecting electric connection of centrifugal pump set, 10 HP, electric dirven, three phase, 415 volts, and taking out from AC Plant transporting the same to work shop, dismentaling the pump set, re-winding the motor with suitable size of cooper enamalled wire, change the bearings , change of shaft if required, change the impalar if required etc, re-assembling the same transport from work shop to site, re-fixing in same position, making etecric connection and testing complete all as specified and directed. Note:- All defective parts deemed to be included in repair cost.
87Disconnecting electric connection of monoblock pump set, 5 HP, electric dirven, three phase, 415 volts, and taking out from AC Plant transporting the same to work shop, dismentaling the pump set, re-winding the motor with suitable size of cooper enamelled wire, change the bearings , change of shaft if required, change the impalar if required etc, re-assembling the same transport from work shop to site, re-fixing in same position, making etecric connection and testing complete all as specified and directed. Note:- All defective parts deemed to be included in repair cost.
88Supply only MCCB415V, 16KA, 4 pole of rating 125A complete all as specified and directed.
89Supply only MCCB415V, 36KA, 4 pole of rating400A complete all as specified and directed.
90S & F in replacement existing doorbell switch with PVC surface box 1 module with 5 amp bell push to a location below window sun shade (Chajja) complete with making the surface good complete all as specified and directed.
91S & F in repairssingle core flexiablePVC cable 1.5 sqmm of standrad copper conductor pvc insulated unsheathed cables of 1100 volts complete all as specified and directed.