}

Tender For Repair/ Replacement To Lt Panels, Apfc Panels And Other Connected Items At Af Stn Sarsawa Under Ge (Af) Sarsawa, sarsawa-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/ Replacement To Lt Panels, Apfc Panels And Other Connected Items At Af Stn Sarsawa Under Ge (Af) Sarsawa. Submission Date for this Tender is 21-03-2024. Electrical Panel Tenders in sarsawa Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42347701
Corrigendum : Tender For Repair/ Replacement To Lt Panels, Apfc Panels And Other Connected Items At Af Stn Sarsawa Under Ge (Af) Sarsawa
Open Tender
Indian
Uttar Pradesh
sarsawa
21-03-2024

Tender Details

Repair / Replacement To Lt Panels, Apfc Panels And Other Connected Items At Af Stn Sarsawa Under Ge ( Af ) Sarsawa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Feb-2024 Amendment01 Terms and Conditions 11-03-2024
2 29-Feb-2024 Amendment01 BOQ 11-03-2024
3 11-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-03-2024
4 18-Mar-2024 Amendment01 Date 21-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: REPAIR/ REPLACEMENT TO LT PANELS, APFC PANELS AND OTHER CONNECTED ITEMS AT AF STN SARSAWA UNDER GE (AF) SARSAWA
Sl. No. Item Description
1Supply, installation, testing & commissioningin replacement of LT panel board, outdoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system,outer body made out of 3.15 mm thick & inner shell made out of 2.00 mm thick CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated , The cubicle shall have frame work, bottom & 45 CM long four legs of size 50 x 50 x 6 mm Angle iron, aluminium main busbar duly sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and control wiring with multistranded PVC insulated copper wire size not less then 1.5 SQMM, complete comprisingwith following accessories all as specified and directed by the Engr-in-charge.(Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed.The cost of the PCC foundation, cable gland and Danger notice plate 02 Nos shall be deemed to be included in the unit rate quoted for the item) : Incoming : Aluminum busbar 4 Pole, of rating 600 Amps.- 01 Set (a)MCCB , 4 pole, 50 KA, 400A, adjustable type with spreader link - 01 No (b) Digital type Amp meter &Voltmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 02 Nos. (b)MCCB , 4 pole, 25 KA, 200A, adjustable type with spreader link - 01 No.
2All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 600 Amps.- 01 Set (a)MCCB , 4 pole, 36 KA, 400A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 02 Nos. (b)MCCB , 4 pole, 18/16 KA, 63A, adjustable type with spreader link - 01 No.
3All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 600 Amps.- 01 Set (a)MCCB , 4 pole, 50 KA, 400A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 01 No. (b)MCCB , 4 pole, 18/16 KA, 100A, adjustable type with spreader link - 01 No. (c)MCCB , 4 pole, 18/16 KA, 63A, adjustable type with spreader link - 01 No.
4All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 400 Amps.- 01 Set (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 18/16 KA, 125A, adjustable type with spreader link - 03 Nos.
5All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 400 Amps.- 01 Set (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 18/16 KA, 125A, adjustable type with spreader link - 01 No. (b)MCCB , 4 pole, 18/16 KA, 100A, adjustable type with spreader link - 01 No. (c)MCCB , 4 pole, 18/16 KA, 63A, adjustable type with spreader link - 01 No.
6All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 400 Amps.- 01 Set (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 18/16 KA, 100A, adjustable type with spreader link - 01 No. (b)MCCB , 4 pole, 18/16 KA, 63A, adjustable type with spreader link - 01 No. (c)MCCB , 2 pole, 10 KA, 40A with spreader link - 06No.
7All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 400 Amps.- 01 Set (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 25 KA, 200A, adjustable type with spreader link - 01 No. (b)MCCB , 4 pole, 18/16 KA, 100A, adjustable type with spreader link - 02 Nos. (c)MCCB , 4 pole, 18/16 KA, 63A, adjustable type with spreader link - 01 No.
8All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 400 Amps.- 01 Set (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 25 KA, 160A, adjustable type with spreader link - 03 Nos. (b)MCCB , 4 pole, 18/16 KA, 100A, adjustable type with spreader link - 02 Nos.
9All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 400 Amps.- 01 Set (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 25 KA, 200A, adjustable type with spreader link - 01 No. (b)MCCB , 4 pole, 18/16 KA, 100A, adjustable type with spreader link - 02 Nos.
10All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 600 Amps.- 01 Set (a)MCCB , 4 pole, 36 KA, 400A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 25 KA, 200A, adjustable type with spreader link - 02 No. (b)MCCB , 4 pole, 18/16 KA, 100A, adjustable type with spreader link - 02 Nos. (c)MCCB , 4 pole, 18/16 KA, 40A, adjustable type with spreader link - 01 No. (d)MCCB , 2 pole, 10 KA, 40A, with spreader link - 03 Nos.
11All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 400 Amps.- 01 Set (a)MCCB , 4 pole, 36 KA, 250A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 18/16 KA, 100A, adjustable type with spreader link - 02 Nos. (b)MCCB , 4 pole, 18/16 KA, 63A, adjustable type with spreader link - 03 Nos. (c)MCCB , 4 pole, 18/16 KA, 32 A, adjustable type with spreader link - 01 No.
12All as per item NO."1" above but with followings:- Incoming : Aluminum busbar 4 Pole, of rating 1000 Amps.- 01 Set (a)MCCB , 4 pole, 50 KA, 630A, adjustable type with spreader link - 01 No. (b) Digital type Amp meter &Volmeter,3 Phase with CT- 01 Set (c) LED indicating lamps three Nos (RYB)-01 Set Outgoing:- (a)MCCB , 4 pole, 36 KA, 400A, adjustable type with spreader link - 03 Nos. (b)MCCB , 4 pole, 18/16 KA, 100A, adjustable type with spreader link - 01 No. Note for srl item no.1 to 12:- (1) All type Test Certificates with switch gears ( ACB & MCCB) as per confirming to IEC: 61439/2011 Par-1 and Part-2 ammended upto date, to be submitted by the contractor alongwith GA drawing for approval before confirmation of order to the panel fabricator. (2) Feeder identification tag as per site is inclusive in the quoted rate.
13M&L for Serviceing of power factor control paneloutdoor/indoor type by fixing of broken hinged doors with welding , replacement of locking arrangement, handle, burnt /rusted out,bus bar as per existing size and shape, control rewiring ,loose or burnt thimble of any size ,old rusted/burnout nuts/bolts & washers, complete tighening of all nuts/bolts insulation tape to all joints refixing of any loose switchgear,cable glands, all unservicable control MCB 5 to 63 Amps, complete including scrapping of surfaces of LTpanel of size upto 3 mtr x 2 mtr x 1.5 mtr, applying two coats of synthetic enameled paint after one coat of primer ,cleaning/cutting of nearby grass bushes all as specified and as directed.
14S&F in replacement of Double door three phase prewired distribution board4 way TPN made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar200 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately)
15M&L for Serviceing of LT panel outdoor/indoor type by fixing of broken hinged doors with welding , replacement of locking arrangement, handle, burnt /rustedout,bus bar as per existing size and shape, control rewiring ,loose or burnt thimble of any size ,old rusted/burnout nuts/bolts & washers,complete tighening of all nuts/bolts insulation tape to all joints refixing of any loose switchgear,cable glands complete including scrapping of surfaces of LTpanel of size upto 3 mtr x 2 mtr x 1.5 mtr, applying two coats of synthetic enameled paint after one coat of primer ,cleaning/cutting of nearby grass bushes all as specified and as directed.
16Disconnecting LT supply and taking out defective LT ACB of cap 400 to 1200Amps any make and rating and servicing by cleaning the fix and moving parts ,removing dust particle by using high speed blower applying greese/jelly to moving mechanism and moving parts, tightening complete, calibration / setting & refixing of ACB complete all as specified and directed by Engr-in-charge.
17Supply and fixing in replacement of adjustable thermal and fixed magnetic release 63 Amps 4 PoleMCCB Breaking capacity 10KA all as specified and directed.
18Supply and fixing in replacement of adjustable thermal and fixed magnetic release 100 Amps 4 PoleMCCB Breaking capacity 10KA all as specified and directed.
19Supply and fixing in replacement of adjustable thermal and fixed magnetic release 125 Amps 4 PoleMCCB Breaking capacity 16KA all as specified and directed.
20Supply and fixing in replacement of adjustable thermal and fixed magnetic release 250 Amps 4 PoleMCCB Breaking capacity 36KA all as specified and directed.
21Supply and fixing in replacement of adjustable thermal and fixed magnetic release 160 Amps 4 PoleMCCB Breaking capacity 35/36KA all as specified and directed.
22Supply and fixing in replacement of adjustable thermal and fixed magnetic release 400 Amps 4 PoleMCCB Breaking capacity Icu 35/36 KA all as specified and directed.
23M&L for Straight through / endjoints heat shrinkable for XLPE/PVC insulated and sheathed aluminium conductor under ground cable 1100 Volts 3.5/ 4 core 06 sqmm to 16 sqmm and testing after jointing complete all as specified and as directed.
24All as per item No. 23here-in-before but for cable 3.5/4 core 25 sqmm to 50 sqmm
25All as per item No. 23here-in-before but for cable 3.5/4 core 70 sqmm to 120 Sqmm
26All as per item No. 23here-in-before but for cable 3.5/4 core 150 sqmm to 185 Sqmm
27Supply only 25 mt long 2.5 cm wide and at least 0.125mm wall thickness PVC tape of good quality all as specified and directed. Make:- Steelgrip, Kinjal, Kalinga
28Material and labourin replacement of earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (1991)& including adequate quantity of charcoal dust and common salt all around earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4)type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate)40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh,and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed. NOTE : Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall bemeasured and paid for separately under appropriate item of Schedule `A’
29Cutting the worn out/unserviceable lugs from the cables upto 50 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
30Cutting the worn out/unserviceable lugs from the cables om 70 Sqmmsize with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
31Cutting the worn out/unserviceable lugs from the cables 95 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
32Cutting the worn out/unserviceable lugs from the cables 120 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
33Cutting the worn out/unserviceable lugs from the cables150 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
34Cutting the worn out/unserviceable lugs from the cables185 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
35Cutting the worn out/unserviceable lugs from the cables from 240 Sqmm to 300 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
36M&L for replacement of 4 pole isolator 63 Amps complete all as specified and directed by Engr-in-charge.
37M&L for replacement of 4 pole isolator 100 Amps complete all as specified and directed by Engr-in-charge.
38Supply and fixing in replacement of Voltmeter of size 96 x 96 having range 0-600V, 3 phase digital type including taking out old unsv complete all as specified and directed by Engr-in-charge.
39Supply and fixing in replacement of Ammeter of size 96 x 96 having range 0-250A , 3 phase digital type including taking out old unsv complete all as specified and directed by Engr-in-charge.
40Supply and fixing in replacement of VAF meter of size 96 x 96 digital type including taking out old unsv complete all as specified and directed by Engr-in-charge.
41Supply and fixing in replacement of Indicator lamp suitable for LT panel as standard colour (R,Y,B) including taking out old unsv complete all as specified and directed by Engr-in-charge.
42Supply and fixing in replacement of lock round type suitable for LT panel as standard including taking out old unsv complete all as specified and directed by Engr-in-charge.
43Supply and fixing in replacement of selector switch suitable for LT panel as standard including taking out old unsv complete all as specified and directed by Engr-in-charge.
44Supply and fixing in replacement of Danger notice plate having conventional skull and bone structure with red paint on sheet metal having thickness not less than 2 mm.suitable for LT panel as standard including taking out old unsv complete all as specified and directed by Engr-in-charge.
45M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 25 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
46M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 15 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
47M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 10 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
48M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 5 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
49M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 3 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
50M&L for replacement of Tempra pro P17 IP 66/67 panel mounted industrial socket inclined output of 63 A, 3P+N+E, 380/415V AC including taking down old unsv socket complete all as specified and directed by Engr-in-charge.
51M&L for replacement of Tempra pro P17 IP44 panel mounted industrial socket inclined output of 32 A, 2P+E, 200/250V AC including taking down old unsv socket complete all as specified and directed by Engr-in-charge.
52S&F in replacement MCB SP 5 to 32 Amps,240 volts curve "B",breaking capacity 10KA including taking down old unsv complete all as specified by Engr-in-charge.
53S&F in replacement MCB DP 20 Amps,240 volts curve "C",breaking capacity 10KA,including taking down old unsv complete all as specified by Engr-in-charge.
54Excavation in trenches in soft/loose soil not exc 1.50 mtrs wide and not exc. 1.5 mtr deep and getting out for taking out/laying cable pole &stay etc complete all as specified and directed by Engineer-in-Charge.
55Returning, filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cm thickcomplete all as specified and directed by Engineer-in-Charge.
56Removal of excavated surplus soil to a distance not exc. 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
57M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and after punning down sand cushioning will be 18 cm complete all as specified and directed by Engineer-in-Charge. Note : 18 cm thick only will be considered for pryment purpose.
58Material labour for common burnt clay bricks, sub class "B" grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
59Supplying, laying, jointing , testing and commisssioning in replacement underground XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured , electric power cable (heavy duty) 1100 volt grade with size of 10 Sqmm 4 core confirming to IS: 7098 part-I ammended upto date, laid in trenches, along pole/wall/across road etc as per site condition including taking out old unsv cable complete all as specified and directed. .Note:- Exacavation/Earth work , brick & sand protection shall be measured and paid saperately.
60All as per item no.59 but of size 16 Sqmm 4 core
61All as per item no.59 but of size 25 Sqmm 4 core
62All as per item no.59 but of size 50 Sqmm 4 core
63All as per item no.59 but of size 70 Sqmm 3.5 core
64All as per item no.59 but of size 95 Sqmm 3.5 core
65All as per item no.59 but of size 120 Sqmm 3.5 core
66All as per item no.59 but of size 185 Sqmm 3.5 core
67All as per item no.59 but of size 35 Sqmm 4 core
68All as per item no.59 but of size 150 Sqmm 4 core
69All as per item no.59 but of size 400 Sqmm 3.5 core
70Supply only electrical contact cleaner bottle having volume not less than 11 fluid ounces suitable for sensitive electric/electronic equipment complete all as specified and directed by Engr-in-charge.
71Supply and fixing in replacement 32 x 6 mm GI strip in short pieces on surface or in recess for all interconnecting, in and including taking out worn out and damaged strip complete all as specified and directed by Engineer-in-Charge.
72M&L for pre polished chequered cement concrete tiles of size 300mm x 300mm x 25mm thick, parallelogram or in any shape of any tint, heavy duty , set jointed and pointed with grey cement slurry, laid over 15 mm thick bedding layer of CM 1:4 complete all as specified and as directed.
73M&L for surface exacavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
74M&L for replacement of GI pipe light grade of size 40 mm bore with all fittings such as socket, union etc complete all as specified and directed.
75M&L for replacement of GI pipe light grade of size 50 mm bore with all fittings such as socket, union etc complete all as specified and directed.
76M&L for RCC pit cover of size as indicated and directed by Engr-in-charge in (1:2:4) type B1 with reinforced bar of 8 mm dia with 100 C/C including lifting handle complete all as specified and directed by Engr-in-charge.
77Taking out tilted earth pit chamber and ramming of sand compacting the area and again repositioning of earth pit chamber over a PCC 1:4:8 of 75mm thick complete all as specified and directed.
78S&F in replacement of Funnel of earth pit chamber made of metal having external thread suitable for GI watering pipe of size 20mm bore complete all as specified and directed.
79Labour only for prunning of tree branches from the site touching/embracing LT overhead lines in order to maintain a clearence of 2 mtr on either side of the conductors incl removing the tree branches from sitecomplete alll as directed.
80Labour for augering upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
81Excavating in post holes (or similar holes) each n.exc 0.50 cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm watering and removing surplus soil n.exc 50m and making good the surface in any type of soil.
82M & L for Cement concrete 1:3:6 type C2 (using 40mm graded aggregate) as in foundations, filling and mass concrete all as specified and directed.
83Fixing only chain link fencing including line wires, any mesh size and type and type of standards, rails, straining bolts etc including provision of binding wire all as specified.
84Supply in replacement of MS galvanished chain link fencing with 3 mm dia of size as required including line wires including strain bolts, binding wire , taking down old damaged fencing complete etc all as directed.
85S&F in replacement ofmild steel screw bolts (machine made) with hexagonal head at one end and screwed the other or screwed both ends each screwed and to be fitted with washers and with hexagonal nut of exc 5 cm length with dia of shanis 11to 15 mm etc all as specified and directed.
86S&F in replacement ofmild steel work such as in fencing post, tie bars etc including embedding into concrete and making holes for screwing of nut, bolts, cutting top to shape as directed, drilling holes, notching for wire etc confirming Fe 410-0 or Fe 310-0 all as specified and directed.
87M&L in replacement for framed work as in doors, gates of angle fe -410 gde E 250 qureed section with gussed plates complete drilled or welded to be prepared for hanging or sliding with and including either hooks and hinges all as directed by Engr-in-Charge.
88M&L for 2 coats of synthetic enamel paint over a coat of red oxide on steel surfaces exc 10 cm width or girth etc.
89M&L in replacement forsteel work in tubular truess, purline rafter columns etc including welding ,butt welded tubes conferming to IS-1161-1979 grade St-240, complete all as directed by Engineer-in-charge.
90S&Fin replacement of Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof coverin/cladding t wall fixed withself tapping screwas as specified fixed etc complete all as specified & directed by Engr-in-Charge.
91M&L in replacement for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 Gde E-165 etc complete all as specified & directed by Engr-in-Charge.
92Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directedby Engr-in-Charge.
93S&F in replacement of mild steel chequered plates duly painted withtwo coat of black bituminous paint over one coat of red oxide primer and cut to shape for cable duct complete all as specified and directed by Engineer-in-Charge.
94M&L for PCC 1: 4 : 8 type D2Using 40 mm graded stone aggregate for foundation of poles complete all as specified and directed .
95M&L for pcc 1:2:4 type B-2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete all as specified.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail