Tender For Repairs / Maintenance And Replacement Of Fire Alram System, Smoke Detectors And Connected Work At Various Otm At Hq Wac Of Age E / M-Ii And Repair / Replacement Of Unserviceable Ug Cable, Lt Panel And Other Allied Work Of Camero Office Comple, delhi-Delhi

Military Engineer Services-MES has published Tender For Repairs / Maintenance And Replacement Of Fire Alram System, Smoke Detectors And Connected Work At Various Otm At Hq Wac Of Age E / M-Ii And Repair / Replacement Of Unserviceable Ug Cable, Lt Panel And Other Allied Work Of Camero Office Comple. Submission Date for this Tender is 16-03-2024. Smoke Detectors Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42347517
Corrigendum : Tender For Repairs / Maintenance And Replacement Of Fire Alram System, Smoke Detectors And Connected Work At Various Otm At Hq Wac Of Age E / M-Ii And Repair / Replacement Of Unserviceable Ug Cable, Lt Panel And Other Allied Work Of Camero Office Comple
Open Tender
Indian
Delhi
delhi
16-03-2024

Tender Details

Repairs / Maintenance And Replacement Of Fire Alram System, Smoke Detectors And Connected Work At Various Otm At Hq Wac Of Age E / M-Ii And Repair / Replacement Of Unserviceable Ug Cable, Lt Panel And Other Allied Work Of Camero Office Complex Dit, Csdo, Afro As Described In Bill Of Quantities

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 94000.0 /-
Tender Value
INR 47 Lakhs /-

BOQ Items

Name of Work: GE/SP/TOKEN-67/2023-2024 : Repairs/Maint and Replacement of Fire Alram system, smoke detectors and connected work at various OTM at HQ WAC of AGE E/M-II AND REPAIR/REPLACEMENT OF UNSERVICEABLE UG CABLE, LT PANEL AND OTHER ALLIED WORK OF CAMERO OFFICE COMPLEX DIT, CSDO, AFRO & AFCAO AREA AT GE(AF) SUBROTO PARK.
Sl. No. Item Description
1M&L for repairs rectification / comprehensive maintenance replacement of faulty service parts of complete fire alarm system installed in HQ WAC BLDG & OPS ROOM AREAall as specified and as directed by Engineer-in-charge. NOTE FOR ITEM NO 1ABOVE :- ALL DEFECTIVE PART WHICH ARE REQUIRED TO REPLACE SHALL BE MEASURED AND PAID SEPERATELY UNDER RESPECTIVE ITEMS (a) FIRE ALARM CONTROL PANEL : The functions of controls panel and indicating equipmentwill be checked by the operation of a trigger device in each zone. All fault indicator and their circuits will be checked by stimulation of fault conditions of any type fie alarm panel. (b) HEAT DETECTOR : Heat detectors will be tested by aim a heat lamp, blow-dryer, or heat gun at the heat detector. The detector alarms should sound within three or four seconds after apply the heat source. (c) SMOKE DETECTOR : Smoke detector will be cleaned periodically so as to remove dust or dirt that accumulates on them due to local ambient conditions at least each detector is cleaned once in month. Smokedetectors will be tested by apply a small spray of smoke detector test aerosol. The detector alarms should sound within three or four seconds after apply the heat source. (d) MANUAL CALL POINT HOOTERS : All manual call points will be operated once a monthly by removing glass or by actual breaking of glass so as to ensure that system is capable of operation under alarm conditions and all hooters give proper sound (e) RESPONSE INDICATORS : All detectors which are placed in side a cabin of room will be tested by initiating the particular detector so as to ensure the proper working of response indicator (f) WIRING & CABLES : A visual inspection will be made so that structure or occupancy changes does not damage cables and sitting of trigger devices (manual call points smoke detector and heat detector. (g) MONTHLY LOG SHEET WILL BE MAINTAINED FOR MONTHLY INSPECTION AND TESTING : Monthly inspection and testing will be done in the monthly maintained log sheet. Log sheet will be produced to the Engineer-in-charge duly complted on Ist day of every month. NOTE :- (a) Replacement of parts will be measured and paid seperately. (b) If service is not carried out by the contractor on due date Rs 1000.00 per day for each service recovery will be made. (c) Contractor will provide One Technician and One helper from 0900 to 1700 hrs in all working days for day to day services. (d)The maint shall be carried out through manufacturer representative or his authorised rep.
2Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable MuliticriteriaType Detector Complete with Dual LED, Hard Addressable Having rotary decade Address swicthes from 01-99, complete with Mounting Base Complete as required Conforming to BS 5839 Standards and Duly Approved by EN54/LPCB//UL complete all as specified and directed by Engineer-in-Charge.
3Supply, installation, testing and commissioning in replacement of fault isolator with base with termination preferably after every 20–30 devices and shall be able to isolate electrical short circuit in the wiring etc. as required complete all as specified and directed by Engineer-in-Charge.
4Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Swicthes for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge.
5Supply, installation, testing and commissioning in replacement of Response Indicators for getting fire indications of detectors installed above false ceiling area interconnecting to loop cable complete all as specified and directed by Engineer-in-Charge.
6Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable Type Control/Output Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Swicthes from 01-99, for initiating Hooter/Sounder/Strobes etc dully approved to GEA GE1-082conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge.
7Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Swicthes from 01-99 dully approved to GEA GE1-082 conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge.
8Supply, installation, testing and commissioning in replacement of Analog Addressable type Active/ Passive Repeater Fire Alarm panel with Backlit LCD Display, having Controls For Reset, Mute, Accept , Silence alarms and Self Test Conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge.
9Supply, installation, testing and commissioning in replacement of Addressable Type Loop Powered Hooter Cum Strobe complete with Mounting Base as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge.
10Supply, installation, testing & commissioning in replacement of 5 Loop Micro processor based 2 wire fault tolerant loop, required loop networkable type (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFFrespective control module when ever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have 20 Zones with Individual LEd Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge.
11Supply & fix in replacement of4"x4" MS junction box for detector mounting complete all as specified and directed by Engineer in Charge.
12Supply & fix in replacement ofbattery maintenance free 6 volt 7 AH complete all as specified and directed by Engineer in Charge.
13Supply & fix in replacementofzone card for fire alarm panel complete all as specified and as directed by Engineer-in-charge
14Supplying, drawing, connecting, testing & commissioning in replacement of 2core, 1.5 sq. mm. stranded copper conductor, pvc insulated PVC sheathed,aluminium myler tape shielded FRLS wire in existing conduit complete all as specified and directed by Engineer-in-Charge. (For Fire Detection & Alarm System)
15Supply and laying in position in replacement of the following sizes of 25/20mm Dia PVC. conduits including providing all accessories complete all as specified and directed by Engineer-in-Charge. (For Fire Detection)
16S & F in replacement of Loop driver card suitable for fire alarm/detection control panel complete all as specified and directed by Engr-in-charge.
17S & F in replacement of RS 485 Communication module complete all as specified and directed by Engineer-in-Charge.
18S & F in replacement of Internal Printer Module complete all as specified and directed by Engineer-in-Charge.
19S & F in replacement of Modbus TCP/IP interface module. Requires an RS485 card to be fitted in the control panel & MI-RJ-45 Cable complete all as specified and directed by Engineer-in-Charge.
20Supply and fix in replacement of SITC 08 Zone conventional panel with Hooter, zone wise fire fault LED and inbuilt MCP, zone wise LED Light zone wise isolation facility including Battery complete all as specified and directed by Engr-in-charge. Note: The total nos of DC battery of item above, the rating and capacity as recommended by the OEM shall be included in the scope and the cost there of shall deemanded to be included in the item rates.
21Supply and fixing in replacement of Photoelectric smoke detector detects the smoke by a couple of infrared diodes, principle of detection isgranule in the smoke can re act infrared light. In orderto reduce the interference and lower power consumption, the emitting circuit adopts the pulse signal,product in accordance with the networking approach is divided into 2-wire and 4-wire detectors complete all as specified and directed by Engineer-in-Charge.
22Supply and fixing in replacement of SITC Red Conventional Call point with LED and Resistor 470 OHM Flush Mounting Flexi Element complete all as specified and directed by Engr-in-charge.
23Supply and fixing in replacement of SITC Conventional HOOTER cum Strobe Flush Mounting Flexi Element complete all as specified and directed by Engr-in-charge.
24Taking down carefully copper/aluminium point wiring( light ,fan, socket or power) complete,fitting such as switches, ceiling roses,pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc.Complete all as specified and directed by Engineer-in-Charge.
25M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20 mm including conduit fittings and accessories concealed in wall / ceiling wiring terminated in flush metal box alongwith outer cover plate for mounting modular/piano switch, socket and electronic regulator along with provn ofearth wire of PVC insulated, unseathed,1100 V grade cable multi stranded FRLS ISI markedcopper conductor of size 1.5 sqmm all asspecified and directed by Engr-in-Charge. For One light point controlled by one switch one way.
26All as per srl item25 above but for one ceiling fan / Exhaust fan point controlled by one switch regulator.
27All as per item No 25 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
28All as per item No 25 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
29All as per item No 25 above but for one light point controlled by two way switches.
30All as per item No 25 above but for Call bell controled by one push button in indipendent board .
31All as per item No 25 above but with 2.5 Sq mm cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
32M&L for point wiring for one light fitting / one fan point controled by one switch with 1.5 Sq mm PVC insulated copper conductor cable drawing in and including PVC Casing/capping or surface conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly with 3mm thick plastic laminated sheet cover completefor one light point controlled by one switch complete all as specified and directed by Engineer in Charge.
33All as per srl item32 above but for one fan point controlled by one switch through regulator.
34All as per srl item 32 above but for one 5 pin 5 amps socket outlet on the independent board.
35All as per item No 32 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
36All as per item No 32 above but for Call bell point.
37All as per item No 32 above but with 2.5 Sqmm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
38M&L for point wiring with 1.5sqmm PVC insulated unsheathed multi stranded copper conductor cable drawing in existingsteel/PVC conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly excluding 3mm sheet metal box and hylam sheet completefor one light point controlled by one switch complete all as specified and directed by Engineer in Charge.
39All as per srl item38 above but for one fan point controlled by one switch through regulator.
40All as per srl item 38 above but for one 5 pin 5 amps socket outlet on the independent board.
41All as per item No 38 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
42All as per item No 38 above but for one light point controlled by two way switches.
43All as per item No 38 above but for Call bell point.
44All as per item No 15 above but with 2.5 Sq mm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
45S&Fin replacement switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed by Eng-in-charge.
46S&Fin replacementswitch piano, flush type single pole, one way, 15 Amps, 240 volts all as specified and directed by Eng-in-charge.
47S&Fin replacement switch piano, flush type single pole, two way, 5 Amps, 240 volts all as specified and directed by Eng-in-charge.
48S&Fin replacement socket16 Amps, 2 in 1, flush type all as specified and directed by Eng-in-charge.
49Supply & fix in replacementbell push, flush type, 5 Amps, 240 volts all as specified and directed by Eng-in-charge.
50Supply and fixing in replacement wall mounted LEDbatten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,20 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cablefrom ceiling rose to fitting,and testing complete all as specified and directed by the Engineer- In- Charge. Make: Havells cat part No-ENDURALINEARNEOBS20WLED865SPCWH or equivalent in Halonix/Crompton Greaves.
51Supply and fixingin replacement wall mounted LEDbatten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cablefrom ceiling rose to fitting,and testing complete all as specified and directed by the Engineer- In- Charge. Make: Havells cat part No-ENDURALINEARNEOBS10WLED865SPCWH or equivalent in Halonix/Crompton Greaves.
52Supply and fixing ultra slimsurface decorative 15 watt with 100 lumen/watt, 6000 K ,230 volt, LED ceiling fitting,complete with all accessories , connecting up with twin core twisted flexible copper conductor cablefrom ceiling rose to fitting, and testing complete all as specified and directed by the Engineer-In- Charge.-Make cart part No EDGEPRORDDLR15WLED840S or equivalent inHalonix/Crompton Greaves
53Supply and fixing wall mounted LED bulk headfittings, 10 watt, warm white, 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cablefrom ceiling rose to fitting, and testing complete all as specified and directed by the Engineer-In- Charge.Make: C& S Cat part No SIRIUS/LTB10WLED or equivalent in Havells /Halonix.
54S&F in replacement of exhaust fan PVC heavy duty non metalic300 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
55S&F in replacement of PVC exhaust fan non metallic type 230-250mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
56S&F in replacement of exhaust fan heavy duty metal body type 230 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
57Supply& fix in replacement of wall mounting fan heavy duty 300/380 mm sweep complete all as specified and as directed by Engineer-in-Charge.
58S&F in replacement of exhaust fan heavy duty plastic body 200 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
59S&F in replacement of PVC exhaust fan non metallic type 200 mm sweep including necessary fixing arrangement for proper fixing in wall and making hole as per site requirement complete all as specified and as directed by Engineer-in-Charge.
60Supply and fixing LED luminire 600mm x 600mm 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
61Taking down existing LT cable off size from various buildings and keep in safe custody for Sch of credit including making good the disterbed surface of road/ path /hard standing etc using suitable materials complete all as specified and directed by Engineer in-Charge.
62Taking out of old defective LT panels from various places of OMQ SP area including removing LT cable connection, earthing strips etc including making good the disturbed surface complete all as specified and directed by Engineer in-Charge.
63M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with selflocking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 1000 amp capacity copper bus bar,wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etcincluding supply and fixingfollowing acessories:- INCOMING (a) ACB 800 Amps, 4 pole, 400 A - 6300 A , 50 KA drowout version of cat No 669540 (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue- set 01 OUT GOING (a) MCCB 320 Amps, 4 pole, 36 KA DPX3 630 cat No 422063 -02 (b) MCCB 250 Amps, 4 pole,36 KA DPX3 250 cat No 420249- 02 Nos (c)MCCB 200 Amps, 4 pole, 36 KA DPX3 250 cat No 420248- 01 Nos (d) MCCB 160 Amps, 4 pole,36 KA DPX3 250 - 01 Foundation-(i) Plateform for the panelwith PCC 1:2:4 type D-2 with 40mm graded crushed stone 15 cm thick in foundation brick work in 1:6 with sub class"B" old size bricks sith sandering 15mm in CM1:6of exposed surface and 100mmthick PCC padding 1:3:6 type C-1 using 20mm graded crushed stomneaggregate on top plate form shall be such that it is of a height 45cm above nearest road level.
64M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with selflocking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 300 amp capacity copper bus bar,wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etcincluding supply and fixingfollowing acessories:-- (Behind SP-16 PANEL No-7) INCOMING (a) MCCB 320 Amps, 4 pole,36 KA DPX3 630 cat No 422006- 1 No (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue- set 01 OUT GOING (a) MCCB 200 Amps, 4 pole, 36 KA DPX3 250 cat No 420248 -01 Nos b) MCCB 125 Amps, 4 pole, 25 KA DPX3 160 cat No 422006 - 01 Nos Foundation-(i) Plateform for the panelwith PCC 1:2:4 type D-2 with 40mm graded crushed stone 15 cm thick in foundation brick work in 1:6 with sub class"B" old size bricks sith sandering 15mm in CM1:6of exposed surface and 100mmthick PCC padding 1:3:6 type C-1 using 20mm graded crushed stomneaggregate on top plate form shall be such that it is of a height 45cm above nearest road level.
65M& L for Fabricate, supply and install cubicle type, CPRI approved LT panel board,outdoor type, totally enclosed,dust & vermin proof (protection class IP 65) front opening with selflocking arrangment made out of MS angle iron frame work, MS flat iron and CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated paint of approved shade. The panel shall be suitable for 415 volts,50 Hz, 3 phase 4 wire system and shall be complete with 300 amp capacity copper bus bar,wiring the panel board with suitable size of PVC insulated, multi stranded copper cables and all connected acessories required for functioning of panel board such as thimbles,glands, bolts, nuts,washers etcincluding supply and fixingfollowing acessories:- INCOMING (a) MCCB 320 Amps, 4 pole,36 KA DPX3 630 cat No 422006- 1 No (b) Digital type volt meter - set 01 (c) Digital type ammeter with suitable rating CTs conforms to relevent IS specification,- set 01 (d) LED type indicator lamp set of red , yellow and blue- set 01 OUT GOING (a)MCCB 200 Amps, 4 pole, 36 KA DPX3 250 cat No 420248- 03 Nos (b)MCCB 125 Amps, 4 pole, 25 KA DPX3 160 cat No 422006 - 02 Nos Foundation-(i) Plateform for the panelwith PCC 1:2:4 type D-2 with 40mm graded crushed stone 15 cm thick in foundation brick work in 1:6 with sub class"B" old size bricks sith sandering 15mm in CM1:6of exposed surface and 100mmthick PCC padding 1:3:6 type C-1 using 20mm graded crushed stomneaggregate on top plate form shall be such that it is of a height 45cm above nearest road level.
66Supply & Fix in replacement of LED Post Top Lantern 25 watt with die cast aluminium spigot, spun aluminium powder coated top cover, Aluminium PDC heat sink, opal PC diffuser and clear arcylic. IP65, Optics: PC lenses with Toughened Glass,electronic driver with input voltage range of 170 to 280V.Make Halonix Cat No- HLPT-04-25-CW or equivalent in Philips/Bajaj.
67Supply & fix in replacementmetal clad socket single pole and neutral sheet metal enclosure with and 20A earth plug and socket complete with one single pole MCB 20 amp 240 Volts all as specified and directed complete all as specified and as directed by Engineer-in- charge.
68S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigidnon- metallic PVC/metallic conduitincl 4.0 Sq mm PVC insulated single core copper conductor cable forcontinuous earth wire. Note:- 3 Runs of 4 Sqmm cable incld conduit shall be measured as one unit length.
69S&F in repair of sub main wiring with 2 single core 06 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigidnon metallic PVCconduit incl 6.0 Sq mm PVC insulated single core copper conductor cable forcontinuous earth wire.Note:- 3 Runs of 4 Sqmm cable incld conduit shall be measured as one unit length.
70Supply and fixing in replacement load line vertical distribution board "A, frame made out of CRCA 2mm thick mild steel sheet,double door, surface mounting TPN 8 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP "A" frame MCCB of 125 Amps =01 No MCBfor outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
71Supply and fixingin replacement MCB distribution board with Bus bar 200A neutral link ,earth bar made out of CRCAmild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
72Taking down old unsv SP/SPN MCBof any size.
73S&F MCB SP 6 to 32 Amps 10 KA, 240 volt "C" Series all as specified and directed by Engineer-in-charge.
74Fixing onlyMCB SPN32/40 Amps 10 KA, 240 volt50 HZrecieved from Sr item No 72 all as specified and directed by Engineer-in-charge.
75Supply & fix in replacement of brass screw 3/18, long threaded suitable for fixing switch boards. ( 100 Nos in one packet)
76Supply & fix in replacement PVC FRLS Flexible cable copper conductor, unsheathed , 1100 volts grade confirming to IS:694/1990 of size 2.5 sqmmcomplete all as specified and as directed by Engineer-in- charge.
77Supply & fix in replacement PVC FRLS Flexible cable copper conductor, unsheathed , 1100 volts grade confirming to IS:694/1990 of size 4.0 sqmmcomplete all as specified and as directed by Engineer-in- charge.
78Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
79Supply and fixing in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
80Supply and fixing in repair LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
81Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
82Supply and fixing in replacement load line vertical distribution board "A, frame made out of CRCA 2mm thick mild steel sheet,double door, surface mounting TPN 8 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP "A" frame MCCB of 125 Amps =01 No MCBfor outgoing comlete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately.
83Supply and fixing in replacement distribution board "A, frame made out of CRCA 2mm thick mild steel sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for FP "A" frame with of MCB 4 pole 100 Amps =01 for incmmer and MCB SPN -18 Nos of 16/32/40 amp for outgoing comlete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately.
84Supply and fixingin replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCAmild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type Cat Part No - DHDPSHODRW08 complete all as specified and as directed by Engineer-in-Charge.Note :- MCB shall be measured and paid seperately.
85M&L forearthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate& copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plateNO 5 of SSR Part I (1991)and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all asspecifiedNote :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note:- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI) complete all as specified and directed by Engr-in-charge.
86S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm strip galvanised iron or steel
87M&L in replacement of earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
88Supply,laying, jointing,testing LT cable 1100 volts grade, PVC insulated armoured and PVC sheathed with stranded aluminium conductor heavy duty,including cable glands, cable lugs etc. to suit the cable size, laid in trenches, fixed along the poles bare or through G.I. Pipe laid under floors road etc;fixed concealed in walls encased in G.I. Pipe etc. complete size of LT cable 400 Sq mm, 3.5 core ofetc all as specified and directed by Engr-in-Charge.
89Supply,laying, jointing,testing LT cable 1100 volts grade, PVC insulated armoured and PVC sheathed with stranded aluminium conductor heavy duty,including cable glands, cable lugs etc. to suit the cable size, laid in trenches, fixed along the poles bare or through G.I. Pipe laid under floors road etc;fixed concealed in walls encased in G.I. Pipe etc. complete sizze of LT cable 120 Sq mm, 3.5 core ofetc all as specified and directed by Engr-in-Charge.
90Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out complete all as specified directed by engineer-in-charge.
91Returning filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm in hard/dense soil complete all as specified directed by engineer-in-charge.
92Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as specified directed by engineer-in-charge.
93M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as specified directed by engineer-in-charge.
94Supply and layingwell burnt sub class ‘B’ bricks old size as mechanicalprotection to under ground cables laying across the cable copmlete all as directed by engineer-in-charge.
95M&L for providing cement concrete type B1, 1:2:4 using 20 mm stone aggrigate in foundation, roof,kerb or mud stops, rounded or chamfered on edges complete all as specified.
96Supply and laying GI pipe light grade galvanizedwith all fittings laid in trenches or fix on wall for cable protection of 80 mm bore complete all as specified directed by engineer-in-charge.
97Material and labour for cuttingof road/ hard standing up to a size not exceeding 20cm widthand not exceeding 60cm in depth for laying ofcable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge.
98Cutting and trimming of tree branches to clear the over head lines enroute of LT over head lines/feeders (including repairing and jointing of ACSR Conductor if damaged during cutting of trees) and removal of the trimmed branches of tree and deposit the same in waste bins inside the campus complete all as directed by Engineer-in-Charge.
99M&L for PCC type D-2 ( 1:4:8)using 40mm graded stone aggregates in foundationincl neccessory form work and fair finish to exposed surface without using extra cement etc.complete all as specified.
100Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 400 sq mm all as specified and directed by engineer-in-charge.
101Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 185 sq mm all as specified and directed by engineer-in-charge.
102Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 120 sq mm all as specified and directed by engineer-in-charge.
103Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 35 sq mm all as specified and directed by engineer-in-charge.
104Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 25 sq mm all as specified and directed by engineer-in-charge.
105Supply and fixing in replacement of brass cable glandssuitable for size of cable 35 sq mm all as specified and directed by engineer-in-charge.
106Supply and fixing in replacement ofbrass cable glands suitable for size of cable 50 sq mm all as specified and directed by engineer-in-charge.
107Supply and fixing in replacement ofbrass cable glands suitable for size of cable 70 sq mm all as specified and directed by engineer-in-charge.
108Supply and fixing in replacement ofbrass cable glands suitable for size of cable 100 sq mm all as specified and directed by engineer-in-charge.
109Supply& fix in replacement of MCCB four Pole 400 Amps, 415 volt thermal release bearing adjestable type breaking cap 50 KA, comlete all as specified and as directed by Engineer-in-Charge.
110Supply& fix in replacement of MCCB four Pole 320/350 Amps, 415 volt thermal release bearing adjestable type breaking cap 36 KA, comlete all as specified and as directed by Engineer-in-Charge.