Regarding Power Factor Improvement Of Apfc Installation At Command Tank-4 In Dwarka Sec 20., Delhi-Delhi

Delhi Jal Board-DJB has published Regarding Power Factor Improvement Of Apfc Installation At Command Tank-4 In Dwarka Sec 20.. Submission Date for this Tender is 26-02-2024. Power Factor Panel Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

42346925
Regarding Power Factor Improvement Of Apfc Installation At Command Tank-4 In Dwarka Sec 20.
Open Tender
Indian
Delhi
Delhi
26-02-2024

Tender Details

Regarding Power Factor Improvement Of Apfc Installation At Command Tank-4 In Dwarka Sec 20.

Key Value

Document Fees
INR 500 /-
EMD
INR 16400.0 /-
Tender Value
INR 8.18 Lakhs /-

BOQ Items

Name of Work :-Regarding power factor improvement of APFC installation at command tank-4 in Dwarka sec 20.
Sl. No. Item Description
1A) RENOVATION OF APFC PANEL : 2 Nos.Dismantling of defective capacitor units from the APFC panel after suitably discharging the left-over charge on capacitors to ensure safety of the working persons along with dismantling of APFC relay, indications lights, meters, A/M switches, MCBs including dismantling of terminations and existing hardware and rusted parts and various other items requiring change in the panel as required at site.
2Replacement of triple pole capacitor duty contactors in place of defective contactor of 12.5 kvar in APFC panels- make Standard
3Replacement of triple pole capacitor duty contactors in place of defective contactor of 5 kvar in APFC panels - make Standard
4Supply of APFC relay, microprocessor based to replace defective APFC relay with digital display of power factor and other parameters to sense power factor through control CT and give phased impulses to contactor coils for switching ON-OFF required number of capacitors as per requirement to achieve target power factor- make STANDARD
5Supply of heavy-duty capacitor units of various capacities, rated at 440v, 3 phase, 50 Hz system complete with terminal cover, cable end entry, mounting structure and hardware etc. -make STANDARD
6Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multi strand copper wires/Al. bus bars using necessary mountings and hardware, etc. as required at site.
7Replacement of 32 A, triple pole MCB in place of defective MCBs of APFC panels - make Standard
8Replacement of cooling fan of 6"x6" size for place of defective fans of APFC panels.
9Replacement of Auto Manual to place defective Auto Manual. Make - L&T
10Supply of LED indication lights of various colours to replace defective/burnt out lights make -Standard
11Fixingof all above components in the APFC panel with suitable fabrication work to accommodate new items in the existing feeders for alignmentof components and easeof termination complete withhardware etc. as required at site
12Servicing of panels including complete dusting of all components, cleaning of contact point with CTC solution , decarbonisingof various joints , tightening of all nut bolts , sleevingof live partsalignmentof doors to prevent ingress of moisture and vermin and touchingof rusted partsof the panels etc.as required at site.
13Testing & commissioning of APFC Panel as per required parameters including following i. Continuity and earth test, ii Programming of APFC relay for target power factor ii. Meggering of all equipment’s for phase to phase andphase to earth. iii. Checking of tightness of all nut and bolts iv. Monitoring of power factor
14B) REPAIR OF STATIC CAPCITORS FRO MOTOR : 03 NOS.Checking of capacitors and dismantling of defective capacitors from static capacitor banks including dismantling of terminations, wirings, hardware, as required at site.
15Replacement of Super Heavy-duty capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC complete with terminal cover and discharge device for replacement of defective capacitors of static capacitor banks -make standard
16Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multistrand copper wires/Al. bus bars using necessary mountings and hardware, etc. as required at site.
17Replacement of triple pole MCCB of 250 A capacity for operation and safety of individual capacitor bank - make Standard
18Installation & connection of capacitors as described above using necessary hardware, mounting arrangement and termination with multistrand copper wires, lugs, tapes etc. as required at site.
19Less: Buy Back of Scrap material of APFC Panel