Tender For Construction Of Residential And Non Residential Building At Neta Ji Subhas Chandra Boss College Tutibari, Nichalaul Distt. Mahrajganj
Tender Value
7.86 Crore
Estimated cost
Bid Submission
23 Feb 2024
0 days left
EMD
15.73 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
nichlaul → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Residential And Non Residential Building At Neta Ji Subhas Chandra Boss College Tutibari, Nichalaul Distt. Mahrajganj
BOQ
| Sl. No. | Item Description |
| 1 | Academic Block(Civil Works) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 5 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 6 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor |
| 7 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 9 | (a) Suspended floors, roofs, landings, balconies and access platform |
| 10 | (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 11 | (c) Foundations, footings, bases of columns, etc. for mass concrete |
| 12 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR LINTEL] |
| 14 | Ground Floor |
| 15 | As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) |
| 16 | Ground Floor |
| 17 | As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 18 | Ground Floor |
| 19 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) All work up to plinth level : |
| 20 | As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. |
| 21 | Ground Floor |
| 22 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 23 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 24 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 25 | Ground Floor |
| 26 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 27 | Ground Floor |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 29 | Ground Floor |
| 30 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) [Plinth Plaster] |
| 31 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 32 | Ground Floor |
| 33 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 34 | Ground Floor |
| 35 | 12mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor two level. |
| 36 | Ground Floor |
| 37 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of ppropriate size and thickness (not less than 2 mm), nailed to the under layerwith rust proof screws and nails and finishing the groove complete as per specifications anddirection of the Engineer-in-Charge |
| 38 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN FLOORING] |
| 39 | Ground Floor |
| 40 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. [IN SKIRTING] |
| 41 | Ground Floor |
| 42 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. [IN FLOORING] |
| 43 | Ground Floor |
| 44 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment tomatch the shade of the slabs, including rubbing and polishing complete.[IN SKIRTING] |
| 45 | Ground Floor |
| 46 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete |
| 47 | Ground Floor |
| 48 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 49 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 50 | (a) 35mm thick Single leaf |
| 51 | (b) Double leaf-Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 52 | M.S WORK IN DOOR WINDOW |
| 53 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge |
| 54 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to steel windows by welding |
| 55 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) WINDOW & VENTILATOR CHAUKHAT |
| 56 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 57 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre(For Internal wall surface) |
| 58 | Ground Floor |
| 59 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 60 | Ground Floor |
| 61 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . (For Ceiling) |
| 62 | Ground Floor |
| 63 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 64 | Ground Floor |
| 65 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 66 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 67 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete |
| 68 | (a) 250 mm x 10mm |
| 69 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 70 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 71 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 72 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 73 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 74 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). |
| 75 | Construction of drain alongwith apron. |
| 76 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment |
| 77 | Supplying and stacking at site.Over burnt (Jhama) brick aggregate 90 mm to 45 mm [FOR SUNKEN AREA] |
| 78 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 79 | Internal Electrificaiton Works |
| 80 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Light Point) |
| 81 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Fan Point) |
| 82 | Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 83 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Plug and conduit) |
| 84 | Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. |
| 85 | Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 86 | Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 87 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 88 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. |
| 89 | Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, \"C\" curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. single pole |
| 90 | 6 - 32 amps.Cat. A |
| 91 | Supply and fixing of 40 Amp. 4 Pole MCB (10KA) |
| 92 | CAT A |
| 93 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) |
| 94 | CAT A |
| 95 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4 way (4 + 12), Double door |
| 96 | Supply and fixing of single pole MCB blanking plate |
| 97 | CAT A |
| 98 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 99 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioningetc. as required.Upto 450 mm sweep |
| 100 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.. |
| 101 | CABLES |
| 102 | Supplying and making end termination with brass compressiongland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. |
| 103 | 50 sqmm 3.5 core |
| 104 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire |
| 105 | 50 sqmm 3.5 core |
| 106 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 107 | 100 mm Dia |
| 108 | Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. |
| 109 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properlyetc. complete as required. |
| 110 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 111 | Supply & fixing ofrecess/Surface/Pendent mounting round 12 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. |
| 112 | Cat. AA |
| 113 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. |
| 114 | BEE 5 Star rated-1200mm sweep |
| 115 | Supply and burying of 40mm dia x 4.5 metres long G.I. pipe, vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No.6 to 8SWG G.I.wire in G.I. pipe upto appron (and from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I.box with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. |
| 116 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. |
| 117 | 50 Sq.mm |
| 118 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and |
| 119 | adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used. |
| 120 | All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. |
| 121 | The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. |
| 122 | The minimum clearances between bus bars shall be as follows : |
| 123 | Phase to phase - minimum 20mm |
| 124 | Phase to neutral-minimum 15mm |
| 125 | L.T.PANEL |
| 126 | Incoming : |
| 127 | One (1) No 200 A 4 pole |
| 128 | Metering : |
| 129 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 130 | One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 131 | One (1) Set of Phase Indication Lamp. |
| 132 | Bus Bar : |
| 133 | One (1) No.200 A, TPN aluminimum bus bar of suitable length. |
| 134 | Outgoing : |
| 135 | Phase indication lamps on each outgoing to be provided. |
| 136 | 100Amps TPN- 1No. |
| 137 | 63Amps TPN-3Nos |
| 138 | OR outgoing as per site requirment |
| 139 | Supply & fixing of7/9 W LED BULB complete in all respect. Make:C&S Electric or Eq |
| 140 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X20/22 watt LED tube light fitting complete including tube on surface complete in all respect. Make:C&S Electric or Eq |
| 141 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX |
| 142 | 300mm sweep. |
| 143 | INTERNAL W/S AND SANITATION |
| 144 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required |
| 145 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 146 | Same as above but for European type W.C. pan with white plastic seat and lid |
| 147 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 148 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 149 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete,including painting of fittings and brackets, cutting and making good the wall wherever required : |
| 150 | Size 450x300x150 mm |
| 151 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 152 | Semi rigid pipe |
| 153 | a) 32mm dia |
| 154 | b) 40mm dia |
| 155 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 156 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required |
| 157 | a) One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 158 | b) Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern |
| 159 | c) Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern |
| 160 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 161 | Granite Stone of approved shade |
| 162 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. |
| 163 | 15mm nominal bore |
| 164 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
| 165 | Providing and fixing Toilet paper holder |
| 166 | a) C.P. brass |
| 167 | SOIL WASTE & VENT PIPES AND FITTINGS - II |
| 168 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. |
| 169 | a) 110mm diameter |
| 170 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 171 | a) 110mm |
| 172 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 173 | a) 110mm |
| 174 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 175 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) |
| 176 | 110/90 mm diameter |
| 177 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. |
| 178 | 110 mm O.D. |
| 179 | 90 mm O.D. |
| 180 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 110x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 181 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. |
| 182 | Size 90 mm |
| 183 | Size 110 mm |
| 184 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. |
| 185 | Size 90x90x90 mm |
| 186 | Size 110x110x110 mm |
| 187 | WATER SUPPLY PIPES AND FITTINGS - III |
| 188 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. |
| 189 | (internal work) |
| 190 | Exposed on wall |
| 191 | 32mm dia nominal bore |
| 192 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. |
| 193 | 32mm dia nominal bore. |
| 194 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 195 | (internal work) |
| 196 | Exposed on wall |
| 197 | 20mm dia nominal outer dia pipes |
| 198 | 25mm dia nominal outer dia pipes |
| 199 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 200 | Concealed work including cutting chases and making good the walls etc. |
| 201 | 15mm dia nominal outer dia pipes |
| 202 | 20mm dia nominal outer dia pipes |
| 203 | 25mm dia nominal outer dia pipes |
| 204 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. |
| 205 | a) 15mm nominal bore |
| 206 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 |
| 207 | a) 15mm nominal bore |
| 208 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 209 | a) 15mm nominal bore |
| 210 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 |
| 211 | a) 15mm nominal bore |
| 212 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 213 | 20mm dia nominal bore |
| 214 | 25mm dia nominal bore |
| 215 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 216 | 25 mm nominal bore |
| 217 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 218 | SCHEDULE OF QUANTITIES FOR INTERNAL SEWERAGE SYSTEM - IV |
| 219 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, |
| 220 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 221 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 222 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 223 | 100mm diameter |
| 224 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 225 | 100mm diameterS.W. Pipe |
| 226 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. |
| 227 | 150mm diameter |
| 228 | 250mm diameter |
| 229 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 230 | 150 mm.dia. RCCPipes |
| 231 | 250 mm.dia. RCCPipes |
| 232 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design |
| 233 | 150 x 100 mm. size P type |
| 234 | With Sewer bricks conforming to IS : 4885 |
| 235 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 236 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 237 | With FPS bricks of class designation 75 |
| 238 | (i) For Sewer Line |
| 239 | Extra for depth of man hole size 90x80 cm |
| 240 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 241 | Extra for depth of man hole size 90x120 cm |
| 242 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design |
| 243 | With 20x20 mm square bar |
| 244 | Boys Hostel Block(Civil Works) |
| 245 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 246 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 247 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 248 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 249 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor |
| 250 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 251 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 252 | (a) Suspended floors, roofs, landings, balconies and access platform |
| 253 | (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 254 | (c) Foundations, footings, bases of columns, etc. for mass concrete |
| 255 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 256 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR LINTEL] |
| 257 | Ground Floor |
| 258 | First Floor |
| 259 | Mumty |
| 260 | As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) |
| 261 | Ground Floor |
| 262 | First Floor |
| 263 | Mumty |
| 264 | As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 265 | Ground Floor |
| 266 | First Floor |
| 267 | Mumty |
| 268 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) All work up to plinth level : |
| 269 | As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. |
| 270 | Ground Floor |
| 271 | First Floor |
| 272 | Mumty |
| 273 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 274 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 275 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 276 | Ground Floor |
| 277 | First Floor |
| 278 | Mumty |
| 279 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 280 | Ground Floor |
| 281 | First Floor |
| 282 | Mumty |
| 283 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 284 | Ground Floor |
| 285 | First Floor |
| 286 | Mumty |
| 287 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) [Plinth Plaster] |
| 288 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 289 | Ground Floor |
| 290 | First Floor |
| 291 | Mumty |
| 292 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 293 | Ground Floor |
| 294 | First Floor |
| 295 | Mumty |
| 296 | 12mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor two level. |
| 297 | Ground Floor |
| 298 | First Floor |
| 299 | Mumty |
| 300 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of ppropriate size and thickness (not less than 2 mm), nailed to the under layerwith rust proof screws and nails and finishing the groove complete as per specifications anddirection of the Engineer-in-Charge |
| 301 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate [IN FLOORING] |
| 302 | Ground Floor |
| 303 | First Floor |
| 304 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate [IN SKIRTING] |
| 305 | Ground Floor |
| 306 | First Floor |
| 307 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate. [IN FLOORING] |
| 308 | Ground Floor |
| 309 | First Floor |
| 310 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate[IN SKIRTING] |
| 311 | Ground Floor |
| 312 | First Floor |
| 313 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete |
| 314 | Ground Floor |
| 315 | First Floor |
| 316 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 317 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 318 | (a) 35mm thick Single leaf |
| 319 | (b) Double leaf-Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 320 | M.S WORK IN DOOR WINDOW |
| 321 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge |
| 322 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to steel windows by welding |
| 323 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) WINDOW & VENTILATOR CHAUKHAT |
| 324 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 325 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading |
| 326 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 327 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre(For Internal wall surface) |
| 328 | Ground Floor |
| 329 | First Floor |
| 330 | Mumty |
| 331 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 332 | Ground Floor |
| 333 | First Floor |
| 334 | Mumty |
| 335 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . (For Ceiling) |
| 336 | Ground Floor |
| 337 | First Floor |
| 338 | Mumty |
| 339 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 340 | Ground Floor |
| 341 | First Floor |
| 342 | Mumty |
| 343 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 344 | Providing & fixing S.S. sliding door bolts ISI marked anodisedor dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 345 | Providing and fixing bright finished S.S. towerbolts (barrel type) with necessaryscrews etc. complete |
| 346 | (a) 250 mm x 10mm |
| 347 | (a) 200 mm x 10mm |
| 348 | Providing and fixing bright finished S.S.handles with screws etc. complete (a) 125 mm |
| 349 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 350 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 351 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 352 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 353 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). |
| 354 | Construction of drain along with apron. |
| 355 | Supplying and stacking at site.Over burnt (Jhama) brick aggregate 90 mm to 45 mm [FOR SUNKEN AREA] |
| 356 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 357 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 358 | Electrification Works |
| 359 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Light Point) |
| 360 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Fan Point) |
| 361 | Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 362 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Plug and conduit) |
| 363 | Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. |
| 364 | Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 365 | Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 366 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 367 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. |
| 368 | Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, \"C\" curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. single pole |
| 369 | 6 - 32 amps.Cat. A |
| 370 | Supply and fixing of 40 Amp. 4 Pole MCB (10KA) |
| 371 | CAT A |
| 372 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) |
| 373 | CAT A |
| 374 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4 way (4 + 12), Double door |
| 375 | Supply and fixing of single pole MCB blanking plate |
| 376 | CAT A |
| 377 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 378 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioningetc. as required.Upto 450 mm sweep |
| 379 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.. |
| 380 | CABLES |
| 381 | Supplying and making end termination with brass compressiongland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. |
| 382 | 50 sqmm 3.5 core |
| 383 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire |
| 384 | 50 sqmm 3.5 core |
| 385 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 386 | 100 mm Dia |
| 387 | Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. |
| 388 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properlyetc. complete as required. |
| 389 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 390 | Supply & fixing ofrecess/Surface/Pendent mounting round 12 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. |
| 391 | Cat. AA |
| 392 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. |
| 393 | BEE 5 Star rated-1200mm sweep |
| 394 | Supply and burying of 40mm dia x 4.5 metres long G.I. pipe, vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No.6 to 8SWG G.I.wire in G.I. pipe upto appron (and from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I.box with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. |
| 395 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. |
| 396 | 50 Sq.mm |
| 397 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and |
| 398 | adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used. |
| 399 | All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. |
| 400 | The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. |
| 401 | The minimum clearances between bus bars shall be as follows : |
| 402 | Phase to phase - minimum 20mm |
| 403 | Phase to neutral-minimum 15mm |
| 404 | L.T.PANEL |
| 405 | Incoming : |
| 406 | One (1) No 200 A 4 pole |
| 407 | Metering : |
| 408 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 409 | One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 410 | One (1) Set of Phase Indication Lamp. |
| 411 | Bus Bar : |
| 412 | One (1) No.200 A, TPN aluminimum bus bar of suitable length. |
| 413 | Outgoing : |
| 414 | Phase indication lamps on each outgoing to be provided. |
| 415 | 100Amps TPN- 1No. |
| 416 | 63Amps TPN-3Nos |
| 417 | OR outgoing as per site requirment |
| 418 | Supply & fixing of7/9 W LED BULB complete in all respect. Make:C&S Electric or Eq |
| 419 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X20/22 watt LED tube light fitting complete including tube on surface complete in all respect. Make:C&S Electric or Eq |
| 420 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX |
| 421 | 300mm sweep. |
| 422 | Plumbing Works |
| 423 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required |
| 424 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 425 | Same as above but for European type W.C. pan with white plastic seat and lid |
| 426 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 427 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 428 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required |
| 429 | Kitchen sink without drain board of size 610x510x200mm |
| 430 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 431 | Semi rigid pipe |
| 432 | a) 32mm dia |
| 433 | b) 40mm dia |
| 434 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. |
| 435 | 15mm nominal bore |
| 436 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 437 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
| 438 | SOIL WASTE & VENT PIPES AND FITTINGS - II |
| 439 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. |
| 440 | a) 110mm diameter |
| 441 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 442 | a) 110mm |
| 443 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 444 | a) 110mm |
| 445 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 446 | Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. |
| 447 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. |
| 448 | 110 mm O.D. |
| 449 | 90 mm O.D. |
| 450 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 451 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. |
| 452 | Size 90 mm |
| 453 | Size 110 mm |
| 454 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. |
| 455 | Size 90x90x90 mm |
| 456 | Size 110x110x110 mm |
| 457 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. |
| 458 | Size 75/90 mm |
| 459 | Size 110 mm |
| 460 | WATER SUPPLY PIPES AND FITTINGS - III |
| 461 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. |
| 462 | (internal work) |
| 463 | Exposed on wall |
| 464 | 32mm dia nominal bore |
| 465 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. |
| 466 | 32mm dia nominal bore. |
| 467 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 468 | (internal work) |
| 469 | Exposed on wall |
| 470 | 20mm dia nominal outer dia pipes |
| 471 | 25mm dia nominal outer dia pipes |
| 472 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 473 | Concealed work including cutting chases and making good the walls etc. |
| 474 | 15mm dia nominal outer dia pipes |
| 475 | 20mm dia nominal outer dia pipes |
| 476 | 25mm dia nominal outer dia pipes |
| 477 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. |
| 478 | a) 15mm nominal bore |
| 479 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 |
| 480 | a) 15mm nominal bore |
| 481 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 482 | a) 15mm nominal bore |
| 483 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 |
| 484 | a) 15mm nominal bore |
| 485 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 486 | 20 mm dia nominal bore |
| 487 | 25mm dia nominal bore |
| 488 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 489 | SCHEDULE OF QUANTITIES FOR INTERNAL SEWERAGE SYSTEM - IV |
| 490 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, |
| 491 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 492 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 493 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 494 | 100mm diameter |
| 495 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 496 | 100mm diameterS.W. Pipe |
| 497 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. |
| 498 | 150mm diameter |
| 499 | 250mm diameter |
| 500 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 501 | 150 mm.dia. RCCPipes |
| 502 | 250 mm.dia. RCCPipes |
| 503 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design |
| 504 | 150 x 100 mm. size P type |
| 505 | With Sewer bricks conforming to IS : 4885 |
| 506 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 507 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 508 | With FPS bricks of class designation 75 |
| 509 | (i) For Sewer Line |
| 510 | Extra for depth of man hole size 90x80 cm |
| 511 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 512 | Extra for depth of man hole size 90x120 cm |
| 513 | Girls Hostel Block(Civil Works) |
| 514 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 515 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift |
| 516 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 517 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 518 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mmapart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor |
| 519 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 520 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 521 | (a) Suspended floors, roofs, landings, balconies and access platform |
| 522 | (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 523 | (c) Foundations, footings, bases of columns, etc. for mass concrete |
| 524 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 525 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). [FOR LINTEL] |
| 526 | Ground Floor |
| 527 | First Floor |
| 528 | Mumty |
| 529 | As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete) |
| 530 | Ground Floor |
| 531 | First Floor |
| 532 | Mumty |
| 533 | As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) |
| 534 | Ground Floor |
| 535 | First Floor |
| 536 | Mumty |
| 537 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) All work up to plinth level : |
| 538 | As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. |
| 539 | Ground Floor |
| 540 | First Floor |
| 541 | Mumty |
| 542 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 543 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 544 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 545 | Ground Floor |
| 546 | First Floor |
| 547 | Mumty |
| 548 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 549 | Ground Floor |
| 550 | First Floor |
| 551 | Mumty |
| 552 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 553 | Ground Floor |
| 554 | First Floor |
| 555 | Mumty |
| 556 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) [Plinth Plaster] |
| 557 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) |
| 558 | Ground Floor |
| 559 | First Floor |
| 560 | Mumty |
| 561 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 562 | Ground Floor |
| 563 | First Floor |
| 564 | Mumty |
| 565 | 12mm thick plaster in 1:3 on ceiling and soffitsof stairs upto floor two level. |
| 566 | Ground Floor |
| 567 | First Floor |
| 568 | Mumty |
| 569 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of ppropriate size and thickness (not less than 2 mm), nailed to the under layerwith rust proof screws and nails and finishing the groove complete as per specifications anddirection of the Engineer-in-Charge |
| 570 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate [IN FLOORING] |
| 571 | Ground Floor |
| 572 | First Floor |
| 573 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate [IN SKIRTING] |
| 574 | Ground Floor |
| 575 | First Floor |
| 576 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate. [IN FLOORING] |
| 577 | Ground Floor |
| 578 | First Floor |
| 579 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate[IN SKIRTING] |
| 580 | Ground Floor |
| 581 | First Floor |
| 582 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing he joints with white cement and matching pigment etc., complete |
| 583 | Ground Floor |
| 584 | First Floor |
| 585 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 586 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 587 | (a) 35mm thick Single leaf |
| 588 | (b) Double leaf-Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 589 | M.S WORK IN DOOR WINDOW |
| 590 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge |
| 591 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to steel windows by welding |
| 592 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) WINDOW & VENTILATOR CHAUKHAT |
| 593 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 594 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading |
| 595 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 596 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre(For Internal wall surface) |
| 597 | Ground Floor |
| 598 | First Floor |
| 599 | Mumty |
| 600 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 601 | Ground Floor |
| 602 | First Floor |
| 603 | Mumty |
| 604 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . (For Ceiling) |
| 605 | Ground Floor |
| 606 | First Floor |
| 607 | Mumty |
| 608 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 609 | Ground Floor |
| 610 | First Floor |
| 611 | Mumty |
| 612 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 613 | Providing & fixing S.S. sliding door bolts ISI marked anodisedor dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 614 | Providing and fixing bright finished S.S. towerbolts (barrel type) with necessaryscrews etc. complete |
| 615 | (a) 250 mm x 10mm |
| 616 | (a) 200 mm x 10mm |
| 617 | Providing and fixing bright finished S.S.handles with screws etc. complete (a) 125 mm |
| 618 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 619 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 620 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 621 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 622 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). |
| 623 | Construction of drain along with apron. |
| 624 | Supplying and stacking at site.Over burnt (Jhama) brick aggregate 90 mm to 45 mm [FOR SUNKEN AREA] |
| 625 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 626 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws |
| 627 | Electrification Works |
| 628 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Light Point) |
| 629 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (Fan Point) |
| 630 | Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrandsingle core Copper Conductor cable in PVC conduit pipe partly concealedin wall&partlylaidin slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit continuity wire, piano type switch & ceiling rose on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 631 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(Plug and conduit) |
| 632 | Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. |
| 633 | Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire |
| 634 | Wiring forcircuit / submainwiringalongwith earth wire withthe following sizes of FRLS PVC insulated, copper conductor single core cable insurface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. |
| 635 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 636 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. |
| 637 | Supplying and fixing 5 amps. to 32 amps. rating, 240/415 V, 10kA, \"C\" curve, miniature circuit breaker (MCB) suitable for inductive load offollowingpolesin the existingMCBDBcomplete with connections, testing andcommissioning etc. as required. single pole |
| 638 | 6 - 32 amps.Cat. A |
| 639 | Supply and fixing of 40 Amp. 4 Pole MCB (10KA) |
| 640 | CAT A |
| 641 | Supply and fixing of 63 Amp. 4 Pole MCB (10KA) |
| 642 | CAT A |
| 643 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4 way (4 + 12), Double door |
| 644 | Supply and fixing of single pole MCB blanking plate |
| 645 | CAT A |
| 646 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 647 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioningetc. as required.Upto 450 mm sweep |
| 648 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.. |
| 649 | CABLES |
| 650 | Supplying and making end termination with brass compressiongland and aluminium lugs for following size of PVC insulatedand PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. |
| 651 | 50 sqmm 3.5 core |
| 652 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire |
| 653 | 50 sqmm 3.5 core |
| 654 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
| 655 | 100 mm Dia |
| 656 | Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer. |
| 657 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properlyetc. complete as required. |
| 658 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 659 | Supply & fixing ofrecess/Surface/Pendent mounting round 12 to 15 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respects. |
| 660 | Cat. AA |
| 661 | Supply of Ceiling Fan with motor of A.C. Permanent insulation capacitor rating confirming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated volage 220/240 volts, 50 Hz, 1-ph A.C.the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. |
| 662 | BEE 5 Star rated-1200mm sweep |
| 663 | Supply and burying of 40mm dia x 4.5 metres long G.I. pipe, vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No.6 to 8SWG G.I.wire in G.I. pipe upto appron (and from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I.box with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. |
| 664 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. |
| 665 | 50 Sq.mm |
| 666 | Supply, installation, testing and commissioning of electrical pane, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.2mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and |
| 667 | adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB\"s to be used. |
| 668 | All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. |
| 669 | The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. |
| 670 | The minimum clearances between bus bars shall be as follows : |
| 671 | Phase to phase - minimum 20mm |
| 672 | Phase to neutral-minimum 15mm |
| 673 | L.T.PANEL |
| 674 | Incoming : |
| 675 | One (1) No 200 A 4 pole |
| 676 | Metering : |
| 677 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 678 | One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 679 | One (1) Set of Phase Indication Lamp. |
| 680 | Bus Bar : |
| 681 | One (1) No.200 A, TPN aluminimum bus bar of suitable length. |
| 682 | Outgoing : |
| 683 | Phase indication lamps on each outgoing to be provided. |
| 684 | 100Amps TPN- 1No. |
| 685 | 63Amps TPN-3Nos |
| 686 | OR outgoing as per site requirment |
| 687 | Supply & fixing of7/9 W LED BULB complete in all respect. Make:C&S Electric or Eq |
| 688 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X20/22 watt LED tube light fitting complete including tube on surface complete in all respect. Make:C&S Electric or Eq |
| 689 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX |
| 690 | 300mm sweep. |
| 691 | Plumbing Works |
| 692 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required |
| 693 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 694 | Same as above but for European type W.C. pan with white plastic seat and lid |
| 695 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require |
| 696 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 697 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required |
| 698 | Kitchen sink without drain board of size 610x510x200mm |
| 699 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 700 | Semi rigid pipe |
| 701 | a) 32mm dia |
| 702 | b) 40mm dia |
| 703 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. |
| 704 | 15mm nominal bore |
| 705 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 706 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms |
| 707 | SOIL WASTE & VENT PIPES AND FITTINGS - II |
| 708 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. |
| 709 | a) 110mm diameter |
| 710 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 711 | a) 110mm |
| 712 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 713 | a) 110mm |
| 714 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 715 | Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. |
| 716 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. |
| 717 | 110 mm O.D. |
| 718 | 90 mm O.D. |
| 719 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 720 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. |
| 721 | Size 90 mm |
| 722 | Size 110 mm |
| 723 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. |
| 724 | Size 90x90x90 mm |
| 725 | Size 110x110x110 mm |
| 726 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. |
| 727 | Size 75/90 mm |
| 728 | Size 110 mm |
| 729 | WATER SUPPLY PIPES AND FITTINGS - III |
| 730 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. |
| 731 | (internal work) |
| 732 | Exposed on wall |
| 733 | 32mm dia nominal bore |
| 734 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. |
| 735 | 32mm dia nominal bore. |
| 736 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 737 | (internal work) |
| 738 | Exposed on wall |
| 739 | 20mm dia nominal outer dia pipes |
| 740 | 25mm dia nominal outer dia pipes |
| 741 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 742 | Concealed work including cutting chases and making good the walls etc. |
| 743 | 15mm dia nominal outer dia pipes |
| 744 | 20mm dia nominal outer dia pipes |
| 745 | 25mm dia nominal outer dia pipes |
| 746 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. |
| 747 | a) 15mm nominal bore |
| 748 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 |
| 749 | a) 15mm nominal bore |
| 750 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 751 | a) 15mm nominal bore |
| 752 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 |
| 753 | a) 15mm nominal bore |
| 754 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 755 | 20 mm dia nominal bore |
| 756 | 25mm dia nominal bore |
| 757 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 758 | SCHEDULE OF QUANTITIES FOR INTERNAL SEWERAGE SYSTEM - IV |
| 759 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, |
| 760 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 761 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 762 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 763 | 100mm diameter |
| 764 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 765 | 100mm diameterS.W. Pipe |
| 766 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. |
| 767 | 150mm diameter |
| 768 | 250mm diameter |
| 769 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 770 | 150 mm.dia. RCCPipes |
| 771 | 250 mm.dia. RCCPipes |
| 772 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design |
| 773 | 150 x 100 mm. size P type |
| 774 | With Sewer bricks conforming to IS : 4885 |
| 775 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 776 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 777 | With FPS bricks of class designation 75 |
| 778 | (i) For Sewer Line |
| 779 | Extra for depth of man hole size 90x80 cm |
| 780 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 781 | Extra for depth of man hole size 90x120 cm |
| 782 | External Sewrage |
| 783 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, |
| 784 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 785 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 786 | Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete. |
| 787 | 250mm diameter |
| 788 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 789 | 250 mm.dia. RCCPipes |
| 790 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 791 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 792 | With FPS bricks of class designation 75 |
| 793 | (i) For Sewer Line |
| 794 | Extra for depth of man hole size 90x80 cm |
| 795 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 796 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 797 | For pipes 100 to 250mm diameter |
| 798 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, |
| 799 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 800 | Pipes, cables etc. not exceeding 80mm dia. |
| 801 | Provding and fixing gun metal non return valve of approved quality (screwed end) |
| 802 | 65 mm nominal bore |
| 803 | a) Horizontal |
| 804 | Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) |
| 805 | 65mm nominal bore. |
| 806 | 50mm nominal bore. |
| 807 | 32mm nominal bore. |
| 808 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. |
| 809 | 65mm diameter pipe |
| 810 | 50 mm diameter pipe |
| 811 | 32 mm diameter pipe |
| 812 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
| 813 | 65 mm nominal bore |
| 814 | 50 mm nominal bore |
| 815 | 32 mm nominal bore |
| 816 | Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for stop cock, withC.I. surface box 100x100x75mm(inside) with hinged cover fixed in cement concrete slab1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : |
| 817 | With F.P.S. bricks |
| 818 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 819 | 25 to 40 mm dia nominal bore |
| 820 | 50 to 80 mm dia nominal bore |
| 821 | Septic Tank & Soak pit (02 Nos) Size :- Length = 5.00 M. Width = 2.00 Total Depth =3.00M |
| 822 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality). |
| 823 | From 0.00 mt to 1.50 mt |
| 824 | 1.50mt to 3.0 mt |
| 825 | 3.0 mt to 4.50 mt |
| 826 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 827 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. |
| 828 | As in item no. 3above but for slabs (Using 1:1.5:3 Mix concrete) |
| 829 | M-150 brick work in 1:6 (one cement and Six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 830 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 831 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 832 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 4 Coarse sand |
| 833 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
| 834 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
| 835 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 836 | Fire Fighting Works |
| 837 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018 |
| 838 | Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018 |
| 839 | Submersible Pump with Boring |
| 840 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart! bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. DSR-2021 SINo. 23.1.1 |
| 841 | 350 mm dia upto 60 mtr. SINo. 23.1.1.2 |
| 842 | 300 mm dia |
| 843 | 60-90 mtr. SI No. 23.1.1.1 |
| 844 | 90-150 mtr. SI No. 23.2.1.1 |
| 845 | 150-220 mtr. SI No. 23.2.1.1 |
| 846 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. DSR-2021 si No. 23.10 |
| 847 | 150 mm nominal size dia having minimum wall thickness 5.00 mm SI No. 23.10.2 |
| 848 | 200 mm nominal size dia having minimum wall thickness 5.40 mm SI No. 23.10.3 |
| 849 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed / plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mru, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fitting & accessories, all complete, for all depths, as per direction of Engineer -in-charge. DSR-2021 SI No. 23.11 |
| 850 | 150 mm nominal size dia SI No. 23.11.2 |
| 851 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assemblv of tube well as oer IS:2800 (Dart n.DSR-2021 SI No. 23.15 |
| 852 | 150 mm dia SI No. 23.15.2 |
| 853 | Providing and fixing M.S. clamp of required dia to the top of casing! housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. DSR-2021 SI No. 23.14 |
| 854 | 200 mm clamp SI No. 23.14.3 |
| 855 | Supplying, filling, spreading & leveling\" gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of\" Engineer-in-charge. DSR-2021 SI No. 23.6 |
| 856 | Development of tube well in accordance with IS : 2800 (part 1) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \"V\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, ilc disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer- in-charge DSR-2021 SI No. 23.12 |
| 857 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing! casing pipe, rmovable as per requirement, all complete for borewell of: DSR-2021 SI No. 23.13 |
| 858 | 200 mm dia SI No. 23.13.3 |
| 859 | Supply of 7.5 HP 3 phase submersible pump |
| 860 | Supply of control panel 3 phase with single phasing preventer |
| 861 | Supply of submersible cable 2.5 sqmm |
| 862 | Supply of 80mm dia MS column pipe having length of 3 mtr each |
| 863 | Open Surface Drain Size 300X450 (68.50 Rmt) |
| 864 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 865 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 866 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 867 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 coarse sand) |
| 868 | 25 mm cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregate of size 12.5 mm and below by volume) laid over set and hardened surface of sturctural slab or base concretefinished with a floating coat of neat cement using cement . |
| 869 | CC Road (265.42 Sqm) |
| 870 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. [DSR-16.1] |
| 871 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.[DSR-2.8.1] |
| 872 | Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation [DSR-4.1.8] |
| 873 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand)[DSR-6.1.2] |
| 874 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuumdewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). |
| 875 | Boundary Wall (243 RMT) |
| 876 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 877 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 878 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 879 | (a) Suspended floors, roofs, landings, balconies and access platform |
| 880 | (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 881 | (c) Foundations, footings, bases of columns, etc. for mass concrete |
| 882 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 883 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) All work up to plinth level : |
| 884 | As in item 3 above but in R.C.C. columns having strength not less than M-20 |
| 885 | As in item 3 but for thelighterbeams i.e. having spans upto 6 m. |
| 886 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 887 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 888 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 889 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 890 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 891 | Finishing walls (two coat) with exterior Emulsion Paint (Apex Approved Brand)Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.25 ltr/ 10sqm over and including priming coat of exterior primer applied @ 0.75 Ltr/ 10 sqm) |
| 892 | Gate 4.50 Mtr |
| 893 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 894 | Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. |
| 895 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) All work up to plinth level : |
| 896 | As in item 3 above but in R.C.C. columns having strength not less than M-20 |
| 897 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 898 | Finishing walls (two coat) with exterior Emulsion Paint (Apex Approved Brand)Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.25 ltr/ 10sqm over and including priming coat of exterior primer applied @ 0.75 Ltr/ 10 sqm) |
| 899 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to steel windows by welding |
| 900 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 901 | GST Extra As per Applicable |
AI Tender Summary
Tender Timeline
Feb 16, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 23, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 24, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender