Tender For Electrification Of 40 Persons Capacity Hostel Barrack And Vivechana Room In Jewar Thana At Gautam Budh Nagar, jewar-Uttar Pradesh

Public Works Department-PWD has published Tender For Electrification Of 40 Persons Capacity Hostel Barrack And Vivechana Room In Jewar Thana At Gautam Budh Nagar. Submission Date for this Tender is 23-02-2024. Electrification Work Tenders in jewar Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42329949
Tender For Electrification Of 40 Persons Capacity Hostel Barrack And Vivechana Room In Jewar Thana At Gautam Budh Nagar
Open Tender
Indian
Uttar Pradesh
jewar
23-02-2024

Tender Details

Electrification Of 40 Persons Capacity Hostel Barrack And Vivechana Room In Jewar Thana At Gautam Budh Nagar

Key Value

Document Fees
INR 854 /-
EMD
INR 174600.0 /-
Tender Value
INR 17.46 Lakhs /-

BOQ Items

Name of Work: Electrification of 40 persons capacity Hostel/Barrack & Vivechana room in Jewar Thana at Gautam Budh Nagar.
Sl. No. Item Description
1Wiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVCconduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement in concreting,complete with 1.5sq.mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit with modular type switch & ceiling rose/angle/ batten holder onM.S. box with module etc. complete in all respect as directed including matching colour wash.
2Wiring point for two ways light with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVCconduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement in concreting,complete with 1.5sq.mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit with modular type switch & ceiling rose/angle/ batten holder onM.S. box with module etc. complete in all respect as directed including matching colour wash.
3Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVCconduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement in concreting,complete with 1.5sq.mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit with modular type switch & ceiling rose/angle/ batten holder onM.S. box with module etc. complete in all respect as directed including matching colour wash.
4Wiring point for plug with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVCconduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement in concreting,complete with 1.5sq.mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit with modular type switch socket complete in all respect including matching colour wash.
5Wiring point for call bell with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVCconduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement in concreting,complete with 1.5sq.mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit with modular type switch complete in all respect including matching colour wash.
6Wiring point for exhaust fan with 1.5 sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVCconduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement in concreting,complete with 1.5sq.mm FRLSH PVC insulated multi strand copper conductor cable as earthwire drawn inside the conduit with modular type switch complete in all respect including matching colour wash.
7Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work
8Supply and fixing of computer board on wall having 3 Nos. 5Amp. Switch/ Socket and 1 No. 15 Amp. Switch/Socket complete in all respect.
9Add for Invertor Wiring in wiring Point for light/ Fan/ Plug with 1.5 mm Cu Wire
10Supply and fixing ofLED Tube Light with metal heavy duty box type batten light fitting 1 X 22 watt suitasble for up to 1X22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect..CAT-AAA 2420 system lumens 110 lm/W, PF>0.95, THD< 80, sheet thikness 0.8 mm, Tube with aluminium heat with 5 year warrantee.
11S/F 7W LED Mirror light. Havells or equivalent make
12Supply and fixing ofrecess/surfacemounting round 15 to 18W LED Down Lighter having Powder coateddie cast aluminium housing withheat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 1980- 2200 systemlumens 110lm/W, pf>0.95 THD<10% at full load , CRI> 80 with 5 year warranty.
13Supply of 10W LED Bulb with 1 year warranty. Havells/Philips make.
14Supply and fixing of water tight oblong 10W LED bulk head luminaire with driver set confirming to IP 65 and aboveprotection.Complete in all respect. Cat AAA 1100 system lumens 110 lm/WPF>0.95 ,THD< 80 with 5 year warranty.
15Supply and fixing of LED Street light Fitting with madatory driver set having die cast aluminium body and lenses suitable for 75Watt. to 90 Watt. Confirming to IP 66 protection complete in all respect. CAT- AAA8250-9000 system lumens high power LED with lenses >110lm/W, pf>.95, THD<10% at full load, CRI>70 potted driver set and restart feature with 5 Year warranty.
16Supply and fixing of call bell of approved make on polished MDFEG/ Teak ply board including making connections etc. complete in all respect.
17Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
18Supply and fixing of electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.
19Erection and testing of ceiling fan and regulator etc. excluding supply of down rod, complete in all respect.
20Supply of ceiling fan with fan motor of A.C permanent insulation, capacitor rating conforming BEE-5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest ammendment the rated voltage 220/240V, 50HZ,1-ph AC the fan assemble should consist of down rod blades, shackle canopies etc and with double ball bearing system. BEE-5 star rated 1200mm sweep.
21Erection and testing of fresh air fan/exhaust fan on the existing hole with suitable size of rag bolts, nuts and washers etc., complete in all respect.
22Supply and fixing of 16 SWG M.S. drum with luvers duly painted including making hole in the wall for fresh air/exhaust fan and finishing properly complete in all respect.
23Supply of metal body ventilating fan 300 mm sweep. Havells/ Crompton/ Bajaj or equivalent make
24Supply of heavy duty exhaust fan 300 mm sweep, 1400rpm. Havells/ Crompton/ Bajaj or equivalent make
25S & F surface/Flush mounting 4ways V TPN distribution board with additional Door without DPX3 160 MCCB complete in all respect, as directed at site byEngineer in charge. Cat A
26S & F surface/Flush mounting 4ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. Cat A
27S & F surface/Flush mounting 12 ways SPN distribution board with additional metal doorwithout MCB complete in all respect, as direct by Engineer in Charge.
28S & F surface/Flush mounting 14 ways double metal door SPN distribution boardwithout MCB complete in all respect, asDirect by Engineer in Charge.
29S&F of 63Amp4 pole MCB (10 KA)C Curve. Cat A
30S&F of 80-100Amp 4 pole MCCB (16 KA)Thermal Magnetic release. Cat A
31S&F of 40 Amp 4 pole MCB (10 KA). Cat-A
32S&F of 40 Amp. DP MCB (10 KA) C Curve. Cat A
33S&F of 63 Amp. DP MCB (10 KA). Cat A
34S & F sheet steel enclosure for S.P/ D.P. MCB with neutral link and earth terminal. Cat A
35S&F of 6 Amp. to 32 Amp. DP MCB (10 KA) C Curve. Cat A
36S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve CAT-A
37Supply & Eracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB"s (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat -B. Incoming-200Amp. MCCB-1 No. Outgoing 100 Amp.MCCB-1Nos. & 63 Amp.MCCB-3Nos.
38Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead oftwo no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respect.
39Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.
40Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect including matching colour wash.
41Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 2.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect including matching colour wash.
42Supply and wiring of submain with two number 6 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 4 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect including matching colour wash.
43Supply and wiring of submain with two number 16 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 10 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect including matching colour wash.
44Supply and wiring of submain with two number 25 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 16 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect including matching colour wash.
45Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. For 150sq.mm, 3.5 core
46Same as above but for 50 sq.mm, 3.5core
47Same as above but for 35 sq.mm, 3.5core
48Same as above but for 10 sq.mm, 4core
49Same as above but for 4 sq.mm, 4core
50Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. for 150 sq. mm, 3.5 core
51Same as above but for 50 sq.mm, 3.5core
52Same as above but for 35 sq.mm, 3.5core
53Same as above but for 10 sq.mm, 4core
54Same as above but for 4 sq.mm, 4core
55Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect. For 150 sq.mm
56Same as above but for 70 sq.mm
57Same as above but for 50 sq.mm
58Same as above but for 25 sq.mm
59Same as above but for 35 sq.mm
60Same as above but for 16 sq.mm
61Same as above but for 10 sq.mm
62Same as above but for 6 sq.mm
63Same as above but for 4 sq.mm
64S/F of Legrand make or equivalent make RJ11 with shutter-1module
65Supply and laying of 4pair telecom cable. Havells or equivalent make.
66Supply and laying coaxial TV cable RG-6 grade, 0.7mm solid copper conductor PE insulated shielded with fine tinned copper braid protected with PVC sheath.
67Supplying and fixing TV antenna socketoutlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
68Supply & Fixing of Moduler switch blanking plate for Moduler switch board.
69Supply and laying of 25 mm dia heavy duty (2mm thick) pvc conduit in slab alongwith reinforcement before concreting and plastering etc., complete in all respect. Used for telephone
70Charges of Boring/ drilling bore well of 100/150mm dia (as required) for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipment s, tools , plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90meter depth below ground level. for all soils
71Providing and supplying of UPVC pipes (SN 8) of the 110mm dia as per IS 15328 (amended up to date) including GST, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / location of site of work complete as specified and directed by Engineer-In-Charge.
72Lowering, Laying and jointing of PVC-U pipes by suitable adhesives, etc in trenches including testing of joints, etc complete as per drawing. Specification and detailed engineering as per direction of Engineer-in-charge. for 110/100 mm outer Diameter
73Supply of 1phase, 14stage, 88m-20m head range, 1.5HP, 100mm bore, 40mm discharge pipe size & 10 L/min-95 L/min discharge capacity submersible pump. Kirloskar/KSB/Crompon or equivalent make
74Supply of 1phase, 220V, 1.5HP control panel. Kirloskar/KSB/Crompon or equivalent make
75Supply and laying of 2.5sq.mm 3core, PVC insulated and PVC sheathed Cu flat/round cable. Havells or equivalent make
76Lowering of pump/motor
77Supply and fixing of Cast Iron (CI) Double Flanged(D/F) sluice valve, CI D/F NRV, CI D/F tee heavy duty, CI D/F bend, sand, sundwa pipe, gate valve, M S clamp, elbow, nipple, boring cover, rubber packing, safety tape, safety wire, motor safety clamp, pump guard etc.
78Labour charges for installation of pump set and electrical connections etc.
79S/L of 16Sq.mm 2 core Al armoured cable
80SITC of 50mm dia M S black pipe " C" class (IS:1239/3589) including cutting, welding etc, providing suitable flanges along with necessary fittings viz. bend, tees, etc. & anti corrosive treatment. Make: Jindal/Qst/Haryana/Tata
81SITC of first aid Hose reel drum with 20mm dia, 30Mtr long rubber pipe shut off nozzle, 25mm dia gate valve complete confirming to IS:884/444. Make: Safeguard/Firex/ Lifeguard/ G Tech/Firematic/ Safex)
82SITC of ISI marked single headed 63 mm dia SSHydrant Valve, comprising of 80mm dia flanged bend 63mm dia SS oblique pattern landing valve complete with blank cap etc. (Make: Safeguard/New Age/Lifeguard/ G Tech/Minimax/Safex)
83SITC of 50mm dia butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets etc. confirming to IS13095. Make: Kalpana/Aarko/Sir/Kartar/Kirloskar
84SITC of 50mm dia non-return valve confirming to IS: 5312 complete with rubber gasket, nuts, GI bolts & washers etc. as required. Make: Kalpana/Aarko/Sir/Kartar/Kirloskar
85SITC of electric driven terrace pump of 450LPM with minimum pressure of 2.0 kg/cm2 complete installation with concrete foundation and suitable base plate by iron channel complete as per requirement. Make: kirloskar/Mather & Platt/other reputed make
86SITC of Automatic panel of terrace pump suitable for 7.5hp terrace pump
87SITC of pressure switch
88Supply and fixing of PVC tank with cover and suitable locking arrangement having 5000 litre capacity@11 per litre. Make Sintex/Ganga
89Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
90Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.