| 1 | Taking down or Dismantling of ACSR or AAC conductors of any size or any make all as specified and directed by Engr-in Charge. |
| 2 | Taking down or Dismantling earth wire or copper conductor, service feeder or distributor span of any size or any make all as specified and directed by Engr-in Charge. |
| 3 | Taking down or Dismantling insulators any type, any size or any make all as specified and directed by Engr-in Charge. |
| 4 | Taking down or Dismantling stay assembly complete. (demolition of concrete, etc. and excavation measured separately |
| 5 | Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6 mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers completeincluding earthing pit, Chemical compound, Earthing leadup to 7.5 m, 20 mm dia medium grade GI watering pipe, G.I. protection pipe 40mm diaeath pit in PCC 1:2:4 type B-1 using 20 mm graded stone agggragate RCC pit cover including earth work complete all as shown electrical palte No-5 of SSR-2009 (Part-I) NOTE:-The unit rate shall include for excavation & earth work in any type of soil/strata, PCC 1:2:4 type B-I for pit & RCC 1:2:4 type B-I for cover with 8mm dia CTD Bar @150mm C/C both way, funnel with watering pipe 20 mm dia medium grade, 15mm dia light grade GI pipe up to 7.5 mtr long, wiremesh complete all as specified and directed. |
| 6 | M&L for earthing with galvanized steel earth plate electrode 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by mean of nuts bolts and washers of steel or GI, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, earth work in any type of soil, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 5 of SSR Part-I 1991and directed by Engr-In-Charge. |
| 7 | M&L for repairing LT panel board by necessary welding to door hinges, and fixing the sliding bolt for proper locking arrangement and making good all electical connection of LT panel Size 1000 x 1200 x 400 mm including replacement of rubber gasket and spray painting complete panel with synthetic enamel paint over a coat of red oxide including preparation of old surface complete all as specified and as directed. |
| 8 | Supply and laying in replacement LT XLPE cable 1100 Volt grade 10 Sqmm 2Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 9 | Supply and laying in replacement LT XLPE cable 1100 Volt grade 16 Sqmm 4 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 10 | Supply and laying in replacement LT XLPE cable 1100 Volt grade 25 Sqmm 4 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 11 | Supply and laying in replacementLT XLPE cable 1100 Volt grade 35 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 12 | Supply and laying in replacementLT XLPE cable 1100 Volt grade 50 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 13 | Supply and laying in replacementLT XLPE cable 1100 Volt grade 70 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 14 | Supply and laying in replacementLT XLPE cable 1100 Volt grade 95 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/ through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 15 | Supply and laying in replacementLT XLPE cable 1100 Volt grade 120 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 16 | Supply and laying in replacementLT XLPE cable 1100 Volt grade 150 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 17 | Supply and laying in replacementLT XLPE cable 1100 Volt grade 185 Sqmm 3.5 Core with stranded aluminium conductor PVC sheathed armoured confirming to IS 1556 laid in trenches/along poles/ through pipe/through duct/walls with necessary lugs and glands, nuts, bolts and washers complete all as specified and directed by Engr-in Charge. |
| 18 | Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/cableetc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth all as specified and directed by Engr-in-Charge |
| 19 | Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed by Engr-in-Charge |
| 20 | Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge |
| 21 | M&L sand cushioning with dry coarse sand to under ground cable 230 mm deep (80 mm below and 150 mm above the cable ) complete all as specified and directed by Engr-in-Charge |
| 22 | M&L brick protection with sub class\"B\" brick laid flat across the cable complete all as specified and directed by Engr-in-Charge. |
| 23 | Boaring holes horizontally under road without damaging the surface of road(minium 1.0mtr below the road surface) with the help of GI tubing of dia not exceeding 100mm dia for pasing of UG cable all as specified and as directed. |
| 24 | Supply & Fixinreplacement MCCB TP with thermal Megnatic release, breaking capacity35 KA, rating 100 Amp, 3 pole,415 volts all as specified and directed. |
| 25 | Supply & Fixinreplacement MCCB TP with thermal Megnatic release, breaking capacity35 KA, rating 200 Amp, 3 pole,415 volts all as specified and directed. |
| 26 | Supply & Fixinreplacement MCCB TP with thermal Megnatic release, breaking capacity35 KA, rating 400 Amp, 3 pole,415 volts all as specified and directed. |
| 27 | Supply & Fixin replacement of MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 25 KA all as specified and directed |
| 28 | Supply & Fixin replacement of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA all as specified and directed |
| 29 | Supply & Fixin replacement of MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 25 KA all as specified and directed |
| 30 | Supply & Fixin replacement of MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 25 KA all as specified and directed |
| 31 | Supply & Fix in replacement of MCCB 3 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA all as specified and directed |
| 32 | Painting of Aluminium pole, flat iron clamps, Junction boxes of security lights on poles including nuts, bolts, washers, with two coats of aluminium paint over a coat of red oxide primer after cleaning/ removal of dust etc. for preparation of steel surfaces all as specified and directed by Engr-in-Charge |
| 33 | M&L PCC (1:2:4) type B1 using 20mm graded stone aggregates as in coping of poles etc including weathering slightly roundded or chamfered angle and throating necessary form work finishing all exposed faces of concrete etc complete all as specified and directed. ( Volume of poles/struts embedded in concrete shall be deducted. ) |
| 34 | S&F shackle type insulator, porcelain, vitreous, white, brown or green of size 75mm height and 90mm dia for working pressure 1100 volts LT complete with insulator 12mm dia bolts, washers and nuts, MS strips of size 31 x 3 mm complete all as specified and directed. |
| 35 | S&F pin type insulator, porcelain, vitreous, white, brown or green of size 75mm height and 90mm dia for working pressure 1100 volts LT complete with insulator 12mm dia bolts, washers and nuts, MS strips of size 31 x 3 mm complete all as specified and directed. |
| 36 | M&L for supplying, stringing and strengthening of over head conductor (ACSR) on existing LT steel tubular pole 6/1x2.59mm aluminium (Weasel) and 1x2.59 steel. including binding and jointing the conductor with and incl 14 SWG binding wire complete all as specified and directed |
| 37 | --ditto-- as per Ser No 36 above but size6/1x2.11mm aluminium (Squirrel) and 1x2.11 steel. |
| 38 | \"--ditto-- as per Ser No 36 above but 6/1x3.59mm aluminium ( mink) and 1x3.59 steel |
| 39 | M&Lfor supplying, stringing and drawing of GI wire 4 mm dia on LT electric lines including binding, jointing etc all as specified. |
| 40 | Supply and fix stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 16 mm dia, including loop type insulator, stay clamps complete all as specified and directed by Engineer-in-Charge. Note :Excavation,earthwork and PCC in foundation shall be measured and paid seperately under respective items of BOQ. |
| 41 | M & L galvanised iron strip 32x6 mm burried in groundconnecting the LT panel to earthing all as specified and directed. |
| 42 | S&F guard craddle, made to shape hexagonal/rectangular or any other shape as required and directed, fabricated out of galvanised steel wire 4mm dia incl binding wire all as specified and directed. |
| 43 | M&L in replacement of GI pipe 40 mm bore light grade with all fittings fixed to pole and laid to floor/ground for mechanical protection of cable of the following sizes:- |
| 44 | \"--ditto-- as per Ser No 43 above but 50 mm bore |
| 45 | \"--ditto-- as per Ser No 43 above but80 mm bore |
| 46 | M & L for aggregate for loose filling of gauge removing old aggregate and laying of polythene for stop the green grass and relaying the new aggregate same Hard core broken to gauge n exc 63mm in sub stations and main receiving station all as specified and directed by Engr-in-Charge |
| 47 | M&L heat shrinkable straight through XLPE/PVC cable joint LT of size 25 sqmm to 50sqmm 3.5 core after dismantling unserviceable one. |
| 48 | All as per item No.47 here in before but of 95 sqmm to 120 sqmm 3.5 core |
| 49 | All as per item No. 47here in before but of 150sqmm to 185/225sqmm3.5 core |
| 50 | S & F LT PVC line seperator 2 way complete all as specified and directed. |
| 51 | S & F LT PVC line seperator 3 way complete all as specified and directed. |
| 52 | Material and labour for cable route indicator post 900 mm long made of precast cement concrete (1:2:4) type B-1, using 20 mm graded stone aggregate, rounded tops as directed and embeded in ground of size 350 x150 x 450 mm below ground and 350 x 100 x 450 mm above ground, applying two coats of cement base paint on plastered surface including writing letters (like LT/HT UG cable, __ feeder etc) with synthetic enamel paint in brown colour in suitable size including earth work and form work complete all as specified and as directed |
| 53 | Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ |