Public Works Department-PWD has published 1 Repair Maintenance Of E And M Services Installed At Juvenile Justice Board Viswas Nagar, Delhi. ( Sh- Pdg Day To Day Routine Maint. Of Electrical Work, Mechanical Work And Lift Operator. 2 ) Supply Installation Testing Commissioning Of Vrs. E. Submission Date for this Tender is 24-02-2024. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Maintenance of Electrical Installations & Fans i/c EDB"s main boards, rising mains, exit sign boards, security lights and compound lights and Operation of 125 KVA capacity DG set with AMF panel from 9 AM to 5 PM on all days excluding Sunday & Gazetted holidays i/c cleaning & routine testing of equipment’s etc. complete as required. Wireman cum Operator: - 1 No. Khallasi :- 1 No. |
2 | Round the clock operation and maintenance of wet-riser/sprinkler, firefighting system, AFA/PAS installed at various places/floors along with panel, water supply pump sets drainage pumps etc. i/c cleaning of panels on all days excluding Sundays & Gazetted holidays complete as required. Operator: - 3 Nos. |
3 | Operation of 1 No. 4 passengers’ capacity, Judges lift and 1 No. 8 Passenger capacity, common lift (both lifts Johnson Make) from 9 AM to 5 PM on all days excluding Sunday & Gazetted holidays i/c cleaning of lift cars etc. complete as required. Lift Operator: - 2 Nos. |
4 | Providing services of the qualified and experienced staff for operation of CCTV surveillance system installed at Juvenile Justice Board and witness room, Vishwas Nagar, Delhi in all working days from 8:00 AM to 8:00 PM excluding Sundays and Holidays etc. i/c cleaning of all CCTV equipments etc. complete as required and as per terms & conditions. — One Job |
5 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group (C) |
6 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C |
7 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
8 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
9 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
10 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
11 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
12 | Providing and lying earth connection from earth electrode with 6 SWG dia G.I wire in 15 mm dia G.I pipe from earth electrode i/c connection with G.I thimble excavation and re-filling as required. |
13 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
14 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
15 | 3 Module (100 mmX75 mm) |
16 | 6 Module (200 mmX75 mm) |
17 | 8 Module (125 mmX125 mm) |
18 | 12 Module (200 mmX150 mm) |
19 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
20 | 5/6 A switch |
21 | 3 pin 5/6 A socket outlet |
22 | 15/16 A switch |
23 | 6 pin 15/16 A socket outlet |
24 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
25 | 2 + 4 way, Double door |
26 | 2 + 6 way, Double door |
27 | 2 + 8 way, Double door |
28 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
29 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
30 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
31 | 100 Amp, 16 KA, TPMCCB |
32 | 125 Amp, 16 KA, TPMCCB |
33 | 250 Amp, 25 KA, TPMCCB |
34 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB"s (but without MCB"s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
35 | 8 way (4 + 24), Double door |
36 | 12 way (4 + 36), Double door |
37 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
38 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed |
39 | 20 mm |
40 | 25 mm |
41 | SITC of 1200 mm sweep ceiling fan, including wiringwith thedown rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing M.S flat Fan hook etc. as required(ISI Mark). |
42 | SITC OF400 mm dia Wall fan suitable for operation on 230 Volt ± 10%, 50 Hz supply to fixed on wall i/c connection with 1.5 Sq.mm PVC insulated PVC sheathed copper conductor single core cable etc. as reqd. |
43 | Supplying, installation, testing and commissioning of heavy duty exhaust fan of 300 mm sweep, 900 RPM confirming to IS 2312/67 complete with louvers and frames in the existing opening including making the hole to suit the size of the above fan, making good the damage, connections, earthing etc. as required. |
44 | Supplying, installation, testing and commissioning of PVC exhaust fan of 250 mm sweep, 1250 RPM with louvers and frames in the existing opening including making the hole to suit the size of the above fan, making good the damage, connections, earthing etc. as required. |
45 | Supplying, Installation, Testing & Commissioning 1200 mm long high efficiency LED linear batten Luminaries having lumens output 2000 and power not more than 20 watt made out of aluminum extruded housing and polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor > 0.90, THD <20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 120 luman per watt and colour temperature of 6000 K, CRI >80 including connection with 1 5 sq. mm PVC insulated copper conductor FRLS cable etc. Complete as required. |
46 | Supplying, Installation, testing and commissioning of 36 to 40 watt surface/recessmounted LED Luminaries of size 1200 mm (Length) x 300 mm (Width) housing made with white powder coated CRCA sheet metal and polycarbonate diffuser suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency not less than 100 luman per watt. and colour temperature of 5700-6500 K, CRI >80 with APFC driver having power factor > 0.90, THD <20% and efficiency > 85% driver should be IC Compliant, with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable with the help of 4 nos. fastener Hook, Clutch wire and sleeve etc. i/c making connections, testing, commissioning etc. complete as required. |
47 | Supplying, installation, testing and commissioning of recessed mounted LED Luminaries of size 600 mm (Length) x 600 mm (Width) housing made with white powder coated CRCA sheet metal and polycarbonate diffuser having minimum lumen output 3600 and power not more than 30 watt suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency not less than 120 luman per watt. and colour temperature of 6000 K, CRI >80 with driver having power factor > 0.90, THD < 20% and efficiency > 85% driver should be IC Complete, with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable with the help of 4 nos. fastener Hook, Clutch wire and sleeve i/c testing, commissioning etc. complete as required. |
48 | Supplying and fixing of existing damaged fitting into 10 to 12 watt 600 mm long high efficiency LED linear batten Luminaries having aluminium extruded housing and polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor > 0.90, THD <20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 100 luman per watt. and colour temperature of 6500 K, CRI >80 including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable with the help of two nos. fastener Hook, etc. as required. |
49 | Supplying, installation, testing and commissioning of 80 to 90 Watt LED having system efficiency4500lumen,Streetlightfittingswithdiecastaluminiumbody, toughed glass and high power LED with lenses suitable for operation on 220 Volt 50 Hz AC supply , IP-66 having efficiency of driver 85% power factor > 0.90.THO<20%withminimum10KVsurge protection.LED life with, L-70/79/80criteria shall be not less than 50000 burning hours etc suitable for operation on 150 to 265V single phase A .C. supply , and colour temperature of 5500 to 6000 K, CRI >80 including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable and suitable GI bracket minimum 1 mtr with clamp for placing the fittingon wall surface i/c connection testing etc. as required. |
50 | Taking out submersible /mono submersible p/set upto 10 HP rating along with G.I Pipe from existing bore well/ sump with the help of chain and pulley block etc. as reqd. i/c cartage from site to workshop as required. |
51 | Lowering of submersible /mono submersible pump set upto 10 Hp rating along with G.I Pipe from existing bore well/ sump with the help of chain and pulley block i/c cartage from workshop to site etc. as required. |
52 | Replacement of defective by S.I.T.C of 3 HP, submersible pump set 12-15 stage, outlet size 50mm, capable of delivering discharge range 70-150 LPM at a head Range 72-40 meter directly coupled with submersible electric motor suitable for 220 volt ± 10% Single phase, 50 HZ Ac supply, with chain pully block and tripot stand taking out the existing pump and lowing new pump complete etc. as reqd. |
53 | Replacement of defective by S.I.T.C of 5 HP, submersible pump set 18 stage, outlet size 50mm, directly coupled with submersible electric motor suitable for 420 volt ± 10% Three phase, 50 HZ Ac supply, with chain pulley block and tripot stand taking out the existing pump and lowing new pump complete etc. as reqd. |
54 | Replacement of defective by S.I.T.C of 7.5 HP, Submersible Monoblock pump set, SuchDel. Size 65mmX50mm electric motor suitable for 420 volt, Three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd. |
55 | Replacement of defective by S.I.T.C of 10 HP, Submersible Monoblock pump set, SuchDel. Size 80mmX65mm electric motor suitable for 420 volt, Three phase, 50 HZ Ac supply, with chain pully block and tripot stand etc. complete as reqd. |
56 | Supply and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. 4 x 16 sq mm. |
57 | Supply and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. 3 x 10 sqmm. |
58 | S & fixing 3.5 X25 sqmm. P.V.C insulated XLPE Al. conducter armoured cable on surface of wall i/c connection testing etc. as required. |
59 | supplying and laying 3.5x50 sq.mm size PVC insulate PVC sheated armoumred al. conductor cable 1.1KV grade as following as reqd. (a) On Surface |
60 | Comprehensive running maintenance and servicing of WTAC/STAC (1.0/1.5/2.0) TR)/ Water Coolers of different makes and models installed at various places including labour change and replacement of all defective minor parts i/c supplying and charging of R-410A/R-22 refrigerant gas in the compressor in case of leakage (Except replacement of compressor) i/c checking the units oiling, greasing, chemical cleaning of condenser coil, cooling coil i/c replacement of defective parts, Air Filter, running capacitor, starting capacitor, starting relay, thermostat switch, wiring kit, 15/20 Amp Plug tip/Industrial socket, flexible wire and tightening the loose connection, complete as required. |
61 | For Summer Season 45 Nos. for 8 Months |
62 | For Winter Season 45 Nos. For 4 Months |
63 | Annual Comprehensive maintenance of Eureka Forbes/Ion Exchange/Kent make 50 LPH R.O. System installed at various location including replacement of all spare parts including power supply, all consumables filter (Particulate filter, Sediment filter, Precarbon filter, Post carbon filter), Booster Pump, D-watering Pump adaptor, water level controller with 2 meter water proof cable, Solenoid Valve, LPS and all other Accessories required for smooth functioning of R.O. System i/c replacement of membrane. RO Mechanic - 1 No. Total Qty. of R.O. in this scope of work (3 Nos. in M- 2533) |
64 | Credit for Dismantle Material |
65 | Assorted wire 1.5/4/6 Sq mm |
66 | Assorted aluminium cable 3 x 10/3.5 x 25/3.5 x 50/4 x 16 |
67 | Assorted Box Piano Type, Modular Type switch/ socket & Plate |
68 | Assorted Ceiling Fan & Exhaust fan |
69 | Assorted LED Batten |
70 | Assorted LED Panel Fitting |
71 | Assorted Street Light |
72 | Assorted submersible pump 3/5/7.5/10 HP |
73 | Assorted MCB 5/32 Amp |
74 | Assorted MCCB/TPN/DP/SPN |
75 | Assorted 100 A, 16kA, TPMCCB |
76 | Assorted 125 A, 16kA, TPMCCB |
77 | Assorted 250 A, 25kA, TPMCCB |