Housing Urban and Rular Development Government Departments Closing in 0 days TDR #42316598

Tender For Construction Of Transit House At Jajpur Road

Issued by Government Departments · panikoili, Odisha
Tender Value
1.20 Crore
Estimated cost
Bid Submission
26 Feb 2024
0 days left
EMD
1.20 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
panikoili → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Transit House At Jajpur Road Building Work

BOQ

Name of Work: Construction of Transit House at Jajpur Road
Sl. No. Item Description
1CIVIL WORKS(PART-I) Earth work in excavation of foundation in hard soil including dressing and levelling the beds within 50m. initial lead and 1.5m. initial lift with cost, conveyance, taxes as per specification and directionof Engineer in charge
2Filling foundation and plinth with good quality river sand with watering and ramming incluing cost, conveyane, cost of all materials and labour etc complete as per direction and specification of Engineer in charge
3Cement concrete (1:3:6) in foundation and plinth using 4cmsize hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers to required thickness including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge
4Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Foundation and Plinth for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor
5ACC Block(625mmx200mmx200mm) having crushing strength not less than 4N/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure and for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor
61st floor
7Head room
8Fly Ash Bricks masonry (25cmx12cmx8cm) having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before use in Superstructure for ornamental flower beds, plinth molding and similar such type of works with all necessary projections, cutting, circular molding, corbelling, watering, curing etc. including cost, conveyances, royalties ofmaterials and cost of all labour with T&P required for the work etc. complete along with testing of strength as per relevant I.S.standard andas per specification & direction of Engineer-in-charge.Ground floor
9RCC work ofM-25 with 20mm and down graded size crushed stone aggregates mixed by concrete mixer, laying in layers and compacting by vibrator & all leads and lifts including frame works including cost, conveyance, cost of all labour, T&P, cost of all materials etc. complete as per direction and specification of Engineer-in-charge. Column base footing
10Column superstructure GF
111st floor
12Head room
13Grade Beam
14Plinth bend
15Lintel bend GF
161st floor
17ChajjaGF
181st floor
19Staircase GF
201st floor
21Roof Beam GF
221st floor
23Head room
24Roof slab GF
251st floor
26Head room
27Cutting, straightening coiled or bent up M.S. Rod or tor steel using SAIL/RINL/TATA/JINDAL STEEL/ SHYAM STEEL includingbending, binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge Ground floor
281st floor
29Head room
30Supplying, fitting & fixing in all floors of M.S.grillsgate in doors and windows with top rails, steel windows, critical frames for windows balustrades of stair case and parapet railing made out of M.S.square bar/flat as per approved drawing and design including making holes in walls and RCC structure, wood work etc and making good to the damages to walls with cement concrete(1:2:4) with hard crusher broken granite stone chips of 12mm to 20mm size(20mm size not to exceed 25%) of approved quality with cost of all materials with cost of welding all T&P, sundreis etc complete in all respect as per specification and direction of Engineer in charge(screws and other hardward required materials to be used in the work shall be of approved quality and specification and shall have to be supplied by the contractor at his own cost In GF Door
31Supplying and Providing of 32mm thick flush door shutters with approved quality of 30mm thick BWR Block board pasted with 1mm thick sunmica door shutter of approved desig and quality with cost of materials and labour etc complete as per specification and direction of Engineer in charge In all floors
32Supplying, fitting, fixing up window (sliding type)made up of aluminium section 151-154, 151-155, as window frame, section No.151-155, 151-153 and 151-167 as shutter frame with 5mm. thick black glass as panel fitted with rubber bending including lucking arrangement including all fitting including cost of materials all taxes, labour, T&P etc. complete as per specification & direction of Engineering-in-charge
33Providing 6mm thick cement plaster in cement mortar (1:4) in all floors finished smooth to inside RCC surfaceafterscrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
341st floor
35Head room
36Providing 12mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to outside surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
371st floor
38Head room
39Providing16mm thick cement plaster in cement mortar (1:6) in all floors finished smooth to inside ceiling surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties ofmaterials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge(Ground floor)
401st floor
41Head room
42Providingfitting and fixing of Colour/printedVitrifiedtile in floor over 20mm thick bed of cement mortar(1:4)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-chargeGF
431st floor
44Providingfitting and fixing of Colour/ printed vitrified tilein dados and skirtingof approved makeover 12mm thick bed of cement mortar(1:3)jointed with neat cement slurry mixed with pigment to match the shades of tiles including cost, conveyances, royaltiesofmaterials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge GF
452nd floor
46Providing, Fitting & Fixing of Stainless steel of 304 grade in handrailing of 50mm diaof 2mm thick circular pipewith balustrade of size 32mmX32mm X2mm @ 0.90mtr. C/C and stainlesssquare pipes bracing of size 32mmx32mmx2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc. with cost, conveyance ofMaterials, Labour, TandP etc required for the complete in all respect and as per specification & direction of Engineer-in-charge
47Painting two coats with anti-fungal resistance Weather Seal Coatof approved shade upto any height by means of brush to outside surface of walls after cleaning the surface including watering, curring etc. complete in all floors including cost, conveyance, taxes of all materials, labours sundries T&P required for the work as per specification and direction of Engineer in charge Ground floor
481st floor
49Head room
50Finishing wall surface with cement based wall putty(water based) of approved make and finished smooth and even surface to receive paintingincluding cost of scaffolding staging charges, conveyance, taxes of all materials and cost of all labour with TandP etc complete as per specification and direction of Engineer in charge GF
511st floor
52Head room
53Painting two coats with approved synthetic enamel paint of approved colour, shade over a coat of primer in iron/wood work including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge GF
54Painting two coats with approved plastic emulsion paint of approved colour, shadeincluding sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour TandP etc complete as per specification and direction of Engineer in charge GF
551st floor
56Head room
57Priming over the plastered surface with one coat of water bound cement primer of approved quality and make including the cost of all materials, labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc. all complete as per the direction of Engineer-in-charge. GF
581st floor outside
591st floor inside
60Head room outside
61Head room inside
62Providing 2.5cm thick grading concrete of prop.(1:2:2) using 6mm size H.G. chips of approved quality & from approved quarry including watering, curing withcost, conveyances, taxes of all materials, cost of all labour, T&P required for the work etc. complete as per direction of Engineer-in-charge1st floor
63Head room
64E.I. Works:-Surface/Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor of ISI markedwith 20 mm dia PVC flexible non metallic conduit with 6A modular type switch ISI marked , and ceiling rose ISI markedof modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge.GROUP-A
65GROUP-B
66GROUP-C
67Group control of point in Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked with 20 mm dia PVC flexible non metallic conduit with 6A modular type switch ISI marked and ceiling rose ISI markedof modular type G.I box with coverof suitable size, modular box with 1.5 sq. Mm FR PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge..(Maximum 02 nos point in one circuit)
68Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge.
69Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)with suitable size modular box & cover including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge.
70Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)with suitable size modular box & cover including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge.
712 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallicheavy duty flexible conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
722 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5)
734 nos single core 2.5 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor .in 25 mm dia non metallicheavy duty flexible conduit(LDB to LSB/5A SOCKET) (4X2.5+2X1.5)
742 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit . (2X4+1X2.5)
754 nos single core 4 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallicheavy duty flexible conduit.(PDB to PSB/GAYSER. POINT/AC POINT) (4X4+2X2.5)
762 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy duty flexible conduit .(PANEL TO BDB EACH QTR) (2X6+1X2.5)
774 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32mm dia non metallicheavy duty flexible conduit.(PANEL TO BDB EACH QTR)
78Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. make for Split ac.
79Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required as per direction of Engg.-in-Charge. 4 moudle(125mmx75mm)
801 moudle(75mmx75mm)
8112 moudle(200mmx150mm)
82Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge . 20 MM
8325 MM
84Supply and fixingmodular type indicator on the existing switch box/cover of Anchor make as required as per direction of Engg.-in-Charge.
85Supplying and installation of AC starter Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .
86Supplying and fixing step regulator modular type on the existingswitch box including connections but excluding box etc. as required as per direction of Engg.-in-Charge.
87Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge.
88S/F of Bakelite angle holder/batten holder (make-Anchor/Havells/Panasonic or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge .
89Supplying,fixing of Blanking plate(modular type)in existing switch box(including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..
90Sub-Head II (Light fitting Fixture & Fan) Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louversany other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge.
91Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan of or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge .(With out fan Regulator)
92SITC of energy efficient LED tube light fittings with decorative batten and LED tube light having power rating not more than 20 watt and lumen output not less than 1800 lumen complete with electronic driver and all other accessories withdiffuser i/c connection etc as required. (Similar to
93SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.( Make :Make: Lighting Technology/wipro/PHILIPS/BajajHavells make)
94SITC of Sleek LED 18 watt surface square type fitting with extruded polycarbonate housing,High optically efficient diffuser, complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.( Make :Make: Lighting Technology/wipro/PHILIPS/BajajHavells make)
95Supplying and fixing of Energy efficient recess mounted square shape 20 W LED luminaireof dimension of 225x 225 x 35 mm consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 1500 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , L70 B50: 30000 hrs (2 yrs warranty)and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. ( Make : PanasonicModel No: PDLM11---S similar modelofBajaj//Trilux/Osram/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved).
96Supplying and fixing of Energy efficient recess mounted square shape 6 W LED luminaireof dimension of 225x 225 x 35 mm consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 6 watt and lumen output of 1500 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , L70 B50: 30000 hrs (2 yrs warranty)and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. ( Make : PanasonicModel No: PDLM11---S similar modelofBajaj//Trilux/Osram/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved).
97Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
98Supplying, Erection, Fixing, connection & testing of LED top Light of elegant look Panasonic/philips/wiproor equievalant reputed make & model A catogory, ISI marked as approved 35 W LED street light having die cast aluminium housing with toughened glasshaving lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street lightmodel will be vide Panasonic model no. PSTM27358or its equivalent of bajaj/Philips/LT/WIPRO makeor equievalant reputed make A catagoryISI marked as approved having warrantied . .The luminaire should be supplied along with bracketmaintenance free for inspection as required as per direction of Engg.-in-Charge.
99TV Supplying and drawing RG6 TV Cable protected with PVC sheath in the with surface/ recessed steel/ PVC conduit as required as per direction of Engg.-in-Charge.
100Supplying and TV socketon the existing modular plate & switch box including connections but excluding modular plate etc. as required as per direction of Engg.-in-Charge.
101BDBS,DB,AC DB,FLOOR PANELS,MCBS Supply and fixing of 12 wayDD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator)
1022+4 way MCB EnclosureDB (GLAZEDdoor)(only each EM. CONNECTION UPS LOAD)
1034 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) Warranty on DB is 2 years.
104Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB ofmake or any other equivallent A catagories reputed make ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.
105Supplying and fixing 63Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABBor equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheRCCBshould be Replacement Warranty will be 5 years
106Supplying and fixing 63Amps TPN 415 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The RCCBshould be Replacement Warranty will be 2 years
107(Earthing) INSTALLATION S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.
108Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
109Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.(DOUBLE RUN TO MAIN PANEL & APFC PANEL ,AC PANEL)
110Supplying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade of following size cables as per direction of Engg.-in-Charge.4core x 16 sq mm
1113.5core x 35 sq mm (To MDB)
112Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
113Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
114Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
115Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin open duct etc as required as per direction of Engg.-in -charge.
116Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.4 core x16sq mm
1173.5 core x35 sq mm
118Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.50 mm dia
119MAIN METERING PANEL S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint is designed asG.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list.
120HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 200mm(W),ofreputed make ISI marked as approved.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge.
1211.5 TR high wall split A.C
122REFRIGRANT PIPINGSupply,installation of hard/soft copper refregrant piping,complete with fitting of bends and other nesessary material to complete the job.1 TR to 3 TR high wall split A.C
123Supply,installation of hard/soft copper refregrant piping,complete with fitting of bends and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C
124Supply,installation & fabrication ofInsulated drain water piping from indoor to nearestdrain point separate to alland other nesessary material to complete the job. 25mm nom. Dia pipe,B1
125Supply,laying of control cableand other nesessary material to complete the job. For 1 TR to3 TR high wall split A.C
126Supply,installation, testing and commissioning of 4 P&T & 14 Extensions Hybrid EPABX System
127Supply,installation, testing and commissioning of RJ11 Modular Complete in concealed manner including termination of cable
128Supply & Laying of 2 Core 0.5mm telephone cable using Rigid PVC Pipe in concealed manner per running metre of cable laid.
129Supply,installation, testing and commissioning of Electronic Push Button Telephone with Caller ID
130Supply,installation, testing and commissioning of GSM FCT Terminal
131Supply,installation, testing and commissioning of Lightening Protector for P&T Lines
132Supply,installation, testing and commissioning of 12v 7 Ah Battery including termination
133Supply,installation, testing and commissioning of RJ45 Modular Complete in concealed manner including termination of cable
134Supply & Laying of Cat 6 cable using Rigid PVC Pipe in concealed manner per running metre of cable laid.
135Supply,installation, testing and commissioning of Patch Panel, 6U Rack, Cable Manager, Cooling Fan x 2 Nos., Earthing Kit, Power Manager
136Supply,installation, testing and commissionining of 1 Mtr Patch Cord
137Supply,installation, testing and commissionining of 3 Mtr Patch Cord
138Wiring withof 2.5 Sq.MM Unarmoured Flexible Speaker Cable as per site with 2mm thick rigid 25 mm PVC pipe, modular boxes, plate, fitting, fixing, connecting and testing of the same etc. as required. (Make-Finolex/ Liberty)
139Supply,installation, testing and commissioning of 8 Channel DVR with 2 Sata Ports
140Supply,installation, testing and commissioning of 4 MP Dome / Bullet Camera with 25 Mtrs IR Range
141Supply & Laying of RG59+ 3 Core cable using Rigid PVC Pipe in concealed manner per running metre of cable laid.
142Supply,installation, testing and commissioning of BNC & DC Connectors
143Supply,installation, testing and commissioning of Bird Canopy
144Supply,installation, testing and commissioning of Wireless Mouse
145Portable Fire Extinguisher System Supplying, installation, testing and commissioning of CO2 type Fire Extinguisher 4.5 kg capacity confirming to IS: 2878 made from ISI marked seamless cylinder confirming to IS: 7285, fitted with ISI marked controlled valve confirming to IS: 3224, high pressure 1mtr discharge hose & horn complete with initial gas charged with carrying handle & wall mounting bracket as per direction of Engineer-in-charge.
146Providing and fixing the signages \"Fire Exit, Fire Exit Arrow Down,Fire Exit Arrow Left,Fire Exit Arrow Right\" of 1.5in height letters in white with green back ground.The size of the board shall be 25cm x 15 cm and shall be fixed at the height of 2 mts
147P.H. Works:-Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipesconforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge.Ground Floor25mm dia PVC ASTM pipe (sch-80)
14832mm dia PVC ASTM pipe (sch-80)
149First Floor 25mm dia PVC ASTM pipe (sch-80)
15032mm dia PVC ASTM pipe (sch-80)
151Second Floor50 mm dia PVC ASTM pipe (sch-80)
152Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipesconforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brassthreaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Jointsall complete as per specification and direction of the Engineer in charge.Ground Floor20mm dia CPVC pipe
15325mm dia CPVC pipe
154First Floor 20mm dia CPVC pipe
15525mm dia CPVC pipe
156Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mmthick wall Ground Floor
157First Floor
158Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of theEngineer in charge.Ground Floor
159First Floor
160Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.Ground Floor
161First Floor
162Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.15 mm dia 2 WAY BIB COCK WITH WALL FLANGE (FLR-CHR-5041NJaquar Make)
16315mm dia CP Health Faucet(ALD-CHR- 577)
16415mm dia CP ANGULAR STOP COCK WITH WALL FLANGE (FLR-MCH-5053N Jaquar Make )
16520mm dia CP CONCEALED STOP COCK EXT HVY WTH WITH FLANGE( FLR-MCH-5083NJaquar)Make
166WALL MIXER NON TELEPHONIC Jaqur make - FLR-MCH-5219N
16715mm dia C.P. Pillar cock (FLR-MCH-5011N Jaquar make)
16832mm dia CP Bottle trap (Jaquar make)-ALD -CHR-769L -300x190cm
169Sink Cock - Jaquar Make - CON-CHR-349KNM
170Soap Dispenser with glass bottle(ACN-CHR-1135N)
171CP soap Dish holder (Jaquar make)-AKP -CHR-35731P
172Towel Ring Round - (As Per Jaquar,Cat no.:ACN-CHR-1121BN)
173600mm long CP towel rail(Jaquar)-ACN-IVY-1111NM
17425mm dia PVC Ballvalve
17532mm dia PVC Ballvalve
17650mm dia PVC Ball valve
17715mm dia CP flange
17815mm dia CP extension piece
179C.P. Waste 11/4\"
180Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering,watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000Ltr Roto-moulded water storage tank (Syntax Make) In SecondFloor
181Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor110mm dia U-PVC SWR pipe (Ashirbad /Sentinity/Supreeme)
182110mm U-PVC door tee
183110mm U-PVC Plain tee
184110mm U-PVC door bend
185110mm U-PVC plain bend
186110mm dia U-PVC \"P\" trap
187110mm dia U-PVC Plain Shoe Bend
188110mm dia U-PVC offset with out ear
189110mm dia U-PVC cowl
190125mm dia CP grating
191Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge.250mm to 375mmthick wall
192Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge.
193Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. WALL MOUNTED -WC WITH PP SOFT CLOSE SEAT Hindware MARIO (20084+21052)
194Supplying all materials, labour, T&P and fixing wash basins including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in charge. Under counter basin(Hindware)10095 LARA
195Supplying all materials, labour, T&P and fixing wash kitchen sink with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. 600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make)
196Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge . Design mirror
197Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etcall complete as per direction of the Engineer in charge.In ground floor
198Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor
199Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.Groundfloor .
200Firstfloor
201Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
202Firstfloor .
203Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 600 x 600mm of size In ground floor
204In First floor
205Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 600x 300 size of In ground floor
206In First floor
207Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance± 8 percent in cement mortar (1:3) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn Superstructure In Ground floor
208In First floor
209Supplying all materials, labour, T&P and fixing granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. In ground floor
210Firstfloor .
211Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs up to 4.30m height
212In first Floor
213Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor
214In first Floor
215Supplying all materials, labour,T&P and providing cement concrete(1:1 ½:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor
216In first Floor
217Supplying all materials, labour, T&P and providing distempering 2 coats to walls with distemperof approved shade on new work to give an even shadeetc all complete as per specification and direction of the Engineer in charge. In Ground Floor
218In First floor
219Finishing wall surface of walls with Acrylic wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.In Ground floor
220In First floor
221Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre\"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I (ISI marked) size 100mm are to be fitted on one side of shutter.
222Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge
223Supply of all materials & laying the waterproofing material Pidifin 2K of Dr.Fixit on equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\"6\" in wall including cleaning,applying and mending as per specification including cost,conveyance,taxes,royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge. in First floor
22412 mm thick cement plaster (1:4) over brick work with cement punning for skirting. In First floor
225Sinking of 150mmdia tubewell through hand boring (water jet ) method (1 nos)-Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge
226Supplying alllabour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge
227Supplying alllabour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres1 x 80
228Supplying alllabour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm diafrom 0 to 360 metres
229Reaming 150mm to 200mm dia from 0 to 360 metres
230Supplying alllabour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres
231Supplying all labour T&P and grouting with cementslurry for salinesealing intheborearoundthe 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge.
232Supplying alllabour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipefrom 0 to 360 metres
233Cost of 150mm dia PVC ASTM pipe (sch-80)
234Cost of 150mm dia PVC pipe Cutting slot
235Cost of150 mm dia C.I. stainer cutting.
236Cost of bentonite powder
237Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge
238Cost and Conveyance of Gravel
239Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge
240Cost and Conveyance of sand
241Supplying all labour T&P and grouting with cementslurry for sanitary sealingintheborearoundthe uppermost 3 metres of125/100mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge.
242Cost of Cement
243Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By Compressor
244Supplying all materials, labour, T&P and constructingBore well protectionchamber of the inside size 650x650x1000hightwith cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ashbrickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4)inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.
245Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge1H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm
246DOL Control panel
24740mm dia steel short piece
248Well cap
24950mm size CI bracket
2502.50sqmm flat cable
25120mm dia rigid UPVC pipes
252Steel rope with cover
25340mm dia HDPE pipe
254Labour charges for lowering including transportation
255EXTERNAL P.H. WORKSupplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. 110mm dia U-PVC Alround Concrete
256160mm dia U-PVC Alround Concrete
257Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm
258Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ashbrickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
259---- do --- addl depth of 0.15m upto 0.90m
260R.C.P.C.Manhole Cover
261Supplying all materials, labour, T&P and constructing man hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
262Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.1.40m dia x 2.00m deep soakway pit
263Construction of 30 users RCCseptic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of theEngineer-in-Charge.
264Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
265Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
266Supplying all materials, labour, T&P and providing shoring and shuttering for foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per specification and direction of the Engineer in charge
267Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeR.C.C floor and roof slabs up to 4.30m height
268RCC beam,Column, girders and bressmer etc
269Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
270Supplying all materials, labour,T&P and providing cement concrete(1:1 ½:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
271Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
272Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
273Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
274Supplying all materials, labour,T&P and providing Vent base in cement concrete(1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
275Supplying all materials, labour, T&P and fitting and fixing H.C.I soil waste ventilating pipes and fittings to walls with nails, bobbins and wooden plugs or laying in trenches including earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge110mm diameter U-PVC SWR pipe
276110mm dia U-PVC Plain shoe bend
277110mm dia U-PVC Cowl
278Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge

AI Tender Summary

OUR REF NO 42316598
AUTHORITY Government Departments
TENDER VALUE 1.20 Crore
LAST DATE 26-02-2024
Authority
Authority Name Road And Building Department
Work Description Construction Of Transit House At Jajpur Road Building Work
Basic Detail
Tender No CCE.Ctc.(RandB)39/2023-24
Bidding Type Tender
Location
City panikoili
State Odisha
Key Dates
Publish Date 17 Feb 2024
Submission Date 26 Feb 2024
Open Date 27 Feb 2024
Finance
Tender Value 1.20 Crore
Tender Fee 10000
EMD 1.20 Lakhs
Exemption Not Available
Document List
a6daf428-354e-4340-96a4-d493c2f9683d.html
BOQ_493956.xls
DTCN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 17, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 26, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 27, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a6daf428-354e-4340-96a4-d493c2f9683d.html

xls

BOQ_493956.xls

pdf

DTCN.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender