}

Tender For Creation Of Manned Submersible Experience Centre At National Institute Of Ocean Technology, Niot Campus, Pallikaranai, Chennai, madras-Tamil Nadu

Government Departments has published Tender For Creation Of Manned Submersible Experience Centre At National Institute Of Ocean Technology, Niot Campus, Pallikaranai, Chennai. Submission Date for this Tender is 26-02-2024. Prime Mover Tenders in madras Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

42302161
Tender For Creation Of Manned Submersible Experience Centre At National Institute Of Ocean Technology, Niot Campus, Pallikaranai, Chennai
Open Tender
Indian
Tamil Nadu
madras
26-02-2024

Tender Details

Creation Of Manned Submersible Experience Centre At National Institute Of Ocean Technology, Niot Campus, Pallikaranai, Chennai , Pre Construction Works Dismantling Of All Paver Blocks Including Stacking Of Serviceable Material As Directed By The Engineer In Charge,And Disposal Of Unserviceable Materialsoutside Site Premises , Earthwork Excavation By Mechanical Means Using Jcb, Poclain,Etc., For Foundations, Footing, Rafts, Plinths, Pools, Under Ground Structures, Etc. In All Types Of Soil Including Dense, Wet Or Dry (Such As Yellow, Murrum, Hard Murrum/Gravel Or Mixture Of Any Kind), In Loose And Slushy Condition, Including Leveling, All Leads And Lifts, Rate To Include Stacking Within The Site Adjacent Plot Wherever Specified And Spreading In Layers To The Required Levels And Disposing The Excess Earth By Carting Away Out Side The Site To The Designated Areas Identified By The Local Authorities. Rate Is Inclusive Of Making Temporary Stepping/ Sloping, Shoring With Planking, Strutting, Sectioning, Trimming, Dressing Of Sides, Leveling Or Grading, Cleaning, Removing And Excavating Loose Pockets And Consolidating Them By Backfilling As Directed, Dewatering Of Surface Water Including Rain Water, Removal Of Slurry Generated While Excavation And Keeping The Area Free Of Water, Excavating Loose Pockets And Compacting The Same. Note: Authorised Working Space If Required Shall Be Considered As Per Is 1200. (Provision Of Slopes If Required For Execution).Excavation Upto 1.50M , Back Filling Available Excavated Earth To Excavated Areas In Layers Of 150Mm With Watering And Compaction. Rate Is Inclusive Of Making Temporary Stepping/ Sloping, Shoring With Planking, Strutting, Dressing Up Embankments: If Required, Bailing/ Pumping Out Of Water To Keep Site Dry While Back Filling; Costs Includes Conveyance Of All Materials, Labour, Machinery Etc. Complete Directed. Note: Authorised Working Space If Required Shall Be Considered As Per Is 1200. , Filling And Banking Approved With Good Quality Earth In Plinths, Basement, Areas Development Etc. Other Than The Back Filling Of Excavated Areas In Layers Not Exceeding 200Mm In Depth, Breaking Clods, Watering, Rolling Each Layer With Vibratory Compactor And At Inaccessible Places With Wooden/ Steel Rammers To Achieve 90 To 95% Proctor Density At Optimum Moisture Content; Dressing Up Embankments; If Required, Bailing/ Pumping Out Of Water To Keep Site Dry While Back Filling; Costs Includes Conveyance Of All Materials, Labour, Machinery Etc. Complete. Proctor Compaction Test To Done After Filling. , Supplying, Filling, Levelling, Watering And Consolidating With Approved Good Quality M-Sand In Layers Of Thickness 150Mm In Foundation & Flooring Of Any Depth Sides Of Foundation Etc., Including Loading, Transporting, Unloading , All Leads And Lifts, Labour, Ramming With Iron Or Wooden Rammers, The Surface Shall Be Flooded With Water For Minimum 24 Hours And Etc., All Complete As Directed. , Anti-Termite Treatment - Providingand Injecting Chemical Emulsion Chlorophyriphos 20 % Emulsifiable With Concentrates 1 % @ 5 Ltr. /Sqmof The Surface Or As Directed By Project Manager,For Pre-Constructional Anti -Termite Treatment And Creating A Continuous Chemical Barrier Under And Around The Column Pits, Wall Trenches, Basements Excavation, Top Surface Of Plinth Filling, Junction Of Wall And Floor Along The External Perimeter Of The Of The Building, Expansion Joints Over The Top Surface Of Consolidated Earth On Which Apron Is To Be Laid, Surroundings Of Pipes And Conduits Etc. Complete As Per Specifications. (Plinth Area Of Building At Ground Floor Only Shall Be Measured For Payment) , Piling Works Boringinallkindsofsoils(Asmetatsite)Gravelshingleetc. Includingwaterbearingstrata,Disposalofearthetc.Takenout Fromboresoutsidethesiteorasdirectedbysiteincharge, Excludingthecostofsteel Reinforcement Butincludingthecostofbentonitesolutionfor Bore Stabilisation Etc. By Using Pumps ( Capacity Minimum35 - 40 Hp) Prior To Placing Concrete, Disposal Of Bentnite Solution Etc As Directed All Complete (Length Of The Pile Shall Be Considered For Payment).Therateshallincludecostofalignmentoftwonos.Ofbarof Required Diameter Which Is To Be Used To Hold The Reinforcement Cage Vertical During Concreting, Making Slurry Vats At Pre Approvedlocationofsite,Usingbentonite,Removal&Shiftingof Bentonite Slurry, Solid, Semisolid Liquid Muck From Vat/Drain, Dry/Wet Soil Mixed With Bentonite And The Surplus Earth Excavated Fromvattooutsideofthesitepremisesbytanker&Other Transport. Piles Shall Be Cast As Per The Schedule Of Cut Off - Level Given In The Execution Drawing.Pile Driving 450 Mm Dia, 18 M Long. , Providing Andinstallingcastinsitureinforcedcementconcrete Pile Of Specified Dia Meter And Length Below The Pile Cap,In M-35 Cement Concrete - Ready Mixed Concrete, Design Mix With Minimumcement400kg/Cum(Useofflyashprohibited) Including Admixture As Approved By Engineer-In-Charge To Carry A Safeworkingloadnotlessthan40t. , R.Cc/P.C.C Works Providing And Laying Required Thickness Of Controlled Plain Cement Concrete Of Pcc 1:4:8 Grade Using Over 20Mm And Down Size Coarse Graded Hard Stone Aggregate For Levelling Course In Pile Cap And Flooring At Any Mass Concrete And Other Similar Works At All Levels And Heights, Elevations, Mechanical Mixing, Transporting And Placing At All Lifts, Ramming With Iron Rammer, Compacting, Levelling, Curing For 7 Days, Shuttering, Dewatering Wherever Necessary, The Cost Of All Materials, Labour, Leads And Lifts, Tools And Plant, Machineries Etc., Complete As Per Specification. (100Mm Thick) (I) Pcc 1:4:8 , (Ii) Pcc 1:2:4 , Providing And Laying Cast-In-Situ Controlled Reinforced Cement Concrete Of The Following Grades Using 20Mm And Down Size Coarse Graded Machine Crushed Hard Stone Aggregate Including Designing The Mix, Weigh Batching, Mechanical Mixing, Transporting And Placing At All Lifts, Vibrating, Consolidating, Curing And Finishing Smooth As Required All Exposed Faces, Complete For The Following Rc Structural And Other Elements Including Formwork Either Straight, Curved, Plain, Tapered Or Sloped, Supplying And Mixing Admixtures, Dewatering Wherever Necessary, The Cost Of All Complete Materials Labour, All Leads And Lifts, Tools, Plant And Machineries, Hire And Fuel Charges And All Other Incidential Charges Etc., All As Per Specifications, Drawings And As Directed, But Excluding Steel Reinforcement, Irc Mesh, Insert Plates Which Will Be Paid For Separately Under Relevant Items. The Rates Quoted Shall Hold Good For All Foundations At Any Depth, Flooring, All Floors, Heights, Levels, Elevation, Below Ground Level, Basement, Trenches, Pits And Etc Complete. Grade: M35. (I) Pile Cap 750Mm Thk , (Ii) Plinth Beams 230 X 450 , (Iii) Grade Slab 175Mm Thk , (Iv) Floor Deck Slab - 75Mm Thk , (V) Pedestal , Providing And Supplying Of Reinforcement Inclusive Oflabour Charges For Cutting, Straitening, Fabricating And Fixing In Position Ms Bars Conforming To Is-432 / High Yield Strength Deformed Bars (Tor Steel) Conforming To Is-1786 Of Fe 415 Grade / For Pro Steel Confirming To Is-1786 Of Fe550 Of All Dia For Reinforcement In All Rcc In Situ Works Including Flooring And Precast Works At All Levels And Heights Above Finished Floor Level For Plinth Beam, Columns, Roof Beam, Roof Slab, Lintel, Sunshade, Loft, Drops, Sill Level Slab And Etc., And For Foundations, Trenches, Pits, Lift Pits Etc., Below Finished Floor Level Including Cost Of Straightening, Cutting, Bending To Shape Fabricating And Tying With 18 Guage Gi Binding Wire, Providing And Fixing Cement Cover Blocks, Dewatering Wherever Necessary Etc., All Complete As Per Drawings And Specifications And As Directed By The Engineer. The Rate To Include Cost Of Steel,Binding Wire, Cement Cover Blocks, All Cuts And Wastes Which Will Not Be Measured. Only Laid Weight Will Be Measured Including Authorised Laps. Cuts And Wastes Will Not Be Measured For Payment. Reinforcement , Approved Plywood Or Steel Plate Shuttering & Centering For Structural Concrete Work In Locations Called For Including Strutting, Propping, Bracing, Bolting, Wedging, Casing, Striking, Removal, Etc. Complete For Any Size, Section, Or Thickness. Props Shall Consist Of Well-Designed Steel Pipes Adequately Braced( Wooden Ballis As Props Shall Not Be Permitted). The Item To Include Centering & Shuttering At All Heights And Levels. Allow For Forming Grooves, Drip Courses, Chamfers, Cut-Outs, Openings, Etc. Were Called For And For Dressing With Approved Shuttering Oil To Prevent Adhesion. Unexposed Concrete Surfaces, Subsequently Left Untreated (In The Condition Obtained On The Removal Of Formwork) Shall Not Constitute Exposed Concrete Work And Shall Be Measured Under This Item Only. Irregular Shapes With Sides That May Not Be Perpendicular To Each Other Or Shapes Not Confirming Rectangular Or Square Shall Not Be Paid Separately. (Quoted Rate To Include All Staging Up To Any Height) (I) Pile Cap 750Mm Thk , (Ii) Plinth Beams 230 X 450 , (Iii) Grade Slab 175Mm Thk , (Iv) Floor Deck Slab - 75Mm Thk , (V) Pedestal , R.C.C/P.C.C Works Providing And Layingbrick Work Using Bricks Of Class Designation75in Foundations And Upto Plinthlevel In Cementmortar1:6( 1 Cement :6 Coarse Sand ) Including,Joints Finished Flush/Raked To 12 Mm Depth, Etc. Complete As Directed By The Engineer In Charge, (Cleaning Andsoaking The Bricks At Leastfor 24 Hours Before Use , Curing Etc. All Complete At All Heights / Depth). Rate To Include Plastering, Waterpoofing As Per Architect. , Fabrication Works Providing, Fabricating,Transporting, Assembling & Erection In Position Of Steel Members For Steel Columns,Built Up Beams Using Structural Tubular Sections (Round, Square Or Rectangular Hollow Tubes Etc. Confirming To Is 4923 / Is 1161, Yield Strength 310 Mpa As Per Latest Is Code) To The Required Profile & Shape As Called For As Per The Drawing & Specifications. This Item Also Includes The Shear Connectors /Studs & Fusion Weld To Top Of Horizontal Member. This Item Also Includes Preparation Of Shop Drawings & Their Approval, Necessary Templates, Adequate Temporary Supports, Scaffolding & Staging, All Cutting, Grinding, Sliding & All Labour, Tools, Plants& Equipments & Operations Etc. Required To Complete The Job As Per Drawing & Specification. Every Precaution To Be Taken To Prevent Rusting Of Sections. This Item Also Includes All Test On Materials & Welded Fabricated Parts As Per Specification & Direction Of Engineer - In - Charge. Temporary Bolts & Nuts (Grade En 8) To Be Used During Assembling & Shall Be Removed Before Site Erection. All Site Erection Bolts Shall Be Hsfg Type Only. The Item To Include Cost Of Sand Blasting On Materials, Application Of Primer & Various Coats Of Internal & External Painting In Fabrication Shop &Final Painting On Site Including All Touch Up Works After Erection As Per Technical Specification. (I)The Scope Of Work For This Item Includes : A) Design & Fabrication Of Any Additional Temporary Structure Including All Type Of Lifting Brackets, Supporting Brackets, Which Will Be Required For Transportation & Erection In Position / Launching Of Fabrication Part Or Completeelement In Position.B) Making Provision & Arrangement For Required Opening / Inserts For Fixing Lights Fixtures & Funning Cable Conduits . C) All Incidentals .Labour, Equipment & Plants Required To Execute & Complete The Job From Fabrication To Erection At Final Position As Per Drawing, Specification & Direction Of Engineer - In -Charge. D) Cleaning & Removing Of All Spoil, Temporary Arrangement For Casting Of Deck Slab.E) All Safety Measures Required To Execute & Complete The Work.F) Procurement Of All Materials From Approved Manufactures & Fabrication. Complete Methodology For Structural Steel Work . Name Of Workshop For Fabrication Works. Testing Facilities & Erection Procedures Etc.To Be Intimated For Approval Of Engineer - In - Charge. G) The Provision Of Temporary Bearing / Sand Jacks For Supporting Steel Members During Erection. H) Provision Of Stability Duringerection Against Wind Load Or Any Other Type Of Loading On Structural Steel Members During Erection. , (Ii) Measurement Shall Be Only For Structural Steel Which Is Erected & Is Part Of Permanent Structure & Paid As Per Approved Shop Drawings. All Wastages,Temporary Works,Jigs, Temporary Assembly Bolts Etc. Are Deemed To Be Included In Quoted Rates . No Allowance Or Increase In Weight For Welding,Nuts & Bolts Etc Will Be Applicable. , Providing And Fixing Bare Galvalume Sheets Of 0.475 Mm Thk With Self Drilling Screws, Ridge Cap And Rainwater Downtake Pipes Including Fixing Skylight Panels With Butyle Sealant Beads. Brand: Jsw. , Flooring & Cladding False Flooring: The System Should Be Of Nominal 600Mm X 600Mm (35Mm Thick) Modular Panels With Heavy-Duty Pedestals. The Total System Weight Shall Not Exceed 40 Kg/Sq.M. The System Shall Be Able To Withstand A Udl Of 2000 Kg/M2 (1117Kg/Sq.Mt) And A Point Load Of 450 Kg/In2 .Panels Shall Be Made Of Steel With An Infill Of Lightweight, Non-Combustible Having Fireresistance, Thermal Insulation, And Flame Resistance Properties At 60 Min Cementitious Material.The Bottom Of The Panel Shall Be Embossed In Hemispherical Shape To Give Strength And Flexural Rigidity.The Infill Material Shall Not Become Loose When The Panels Are Cut. Panel Should Be Able Towithstand An Ultimate Load Of At Least 2.5 (3.00) Times The Designed Point Load.The Entire Panel Shall Be Coated With Epoxy Powder Coating Of 75-100 Microns On The Exposed Surface.The Panel Top & Bottom Sheet Shall Be 0.9/0.7Mm (0.7/0.6Mm) Resp. Flatness Should Be 0.2Mm.The Panels Shall Have A Top Covering Of Anti-Static High Pressure Laminate With Resistance Of 2X105 –5X108 Ohms. The Hpl Thickness Shall Not Be Less Than 1.5Mm.(1.6Mm).Pedestal Base Shall Be Square Of 100Mm X 100Mm X 2Mm Bearing Area And Assemble To A Tube Of 22Mm Dia With 2Mm Wall Thickness. The Pedestal Head Should Not Be Less Than 3Mm Thick.The Pedestals Should Be Able To Accept An Axial Load Of 22,500N And An Ultimate Load Not Lessthan 45,000N. Pedestal Head Shall Be Galvanized Die-Cut Steel Welded To A Counter Locking Leveling Nut.The Pedestal Head Shall Be Provided With Pvc Cap For Acoustic Dampening. Height Of Pedestal Shall Be Approximate 300 Mm For Floor /150Mm For Steps. , Providing And Fixing Aluminium Composite Panel Of Eurobond/Aludecor Make, Cladding In Combination Of Metallic / Solid Colours, Including All Necessary Frames Work And All Complete. Panel Should Consist Core Of Anti-Toxic Low Density Polyethylene (Ldpe) 3.5Mm Sandwiched Between 2 Skins Of Thick Aluminium Coil Of 0.25Mm. The System Shall Be Installedusing50mm X 50Mm X 50Mm Long 3Mm Thickness G.I L Brackets / 75Mmx50mmx50mm Long 3Mmthicknessg.I.L Brackets @ Min 1.5 Metre Interval Vertically Fastened By 8Mm Dia X 75Mm Long Double Ring/Single Ring Wedge Anchors And 6Mm X 60Mmlong Rawal P/T Type Anchor Fastener Of Uip Brand(Germany Make). 38Mm X 38Mm Thick And 38Mm X25mm L-Angle And 50Mm X 25Mm Box Section Will Be Used For Mullions And Transom With Necessary Accessories, Such As Screws, Rivets, Bolts, Nuts And Washers Shall Be In Zinc Coated/Galvanized Steel.The Bracket Support Shall Be Designed As Per Manufacturers Specification. Sealing Shall Be Done, Using Weather Sealant Of Dowsil Or Equivalent. , Providing And Fixing Corrugated Sheet Cladding In Exterior Elevation In Area / Color As Specified By The Architect To Be Done With Required Channels As Per Manufacterers Specifications. , Providing Andfixing Of 12Mm Thick Bison Board False Ceiling: Metal Framed Suspended Ceiling (Seamless Finish) - Single Layer.False Ceiling Erection To Be With Required Perimeter Channels, Intemediates & Cross Channels As Per Manufacterers Specifications. 6 X 4 Bison Board Fixed With 25Mm Long Self Drilling Screwws With Philips Head. Surface To Be Finished With Jointing Compound And Fibre Taped , Ready To Take Paint Finish.Fixing Channel Size: , Providing Andfixing Of 12Mm Thick Bison Board Partition Walls: To Be Done With Required Channels As Per Manufacterers Specifications On Both Sides Of The Walls/ Partitions. Fixing Channel Size: 65 X 30 Mm / As Per Vendor. , Providing Andfixing Of 9Mm Thick Laminate Cladding On Interior Walls: To Be Done With Required Channels As Per Manufacterers Specifications On Both Sides Of The Walls/ Partitions. 1350 X 295 Panel , Brand : Vox , Providing Andfixing Of Parametric Mdf Panel With Laminate Finish-Fire Rated To Be Done With Required Channels As Per Manufacterers Specifications On Specified Walls/ Partitions, Panel Size 8 X 4 , Base Board 25Mm= 1 Sheet & Parametric Panel 11Mm (Vertical)= 45 Strip, Brand: Glopanel, Fixing Channel Size: 65 X 30 Mm / As Per Vendor. , Providing And Laying Groundcover - Pebbles - Size 50-75Mm Below Staircase. , Providing And Laying Carpet Flooring Over False Flooring, Color And Pattern As Specified By The Architect. , Providing Andfixing Of Vinyl Printed Display Boards On Interior Walls: To Be Done With Required Channels As Per Manufacterers Specifications On Both Sides Of The Walls/ Partitions. , Providing And Laying Machine Cut, Leather Polished Granite Slab Flooring Of Approved Sample, 18Mm Thick And Size As Per Drawings, In Approved Pattern, As Per The Drawings Provided By The Architect, By Applying Mortar To The Substrate With The Flat Side Of The Trowel, Pressing Firmly To Work It Into The Surface; Combing On Additional Mortar With The Notched Side Ue The Proper Sized Notched Trowel For The Stone To Ensure Full Bedding Of The Stone On Checkered Plate Etc. Complete. , Door / Window / Glass Work Providing And Fixing Steel Door Of Size As Mentioned Below With Tata Pravesh Brand -Constructed From 0.0008M Swg Gi Sheet. 0.046M Thk, Frame Of 0.1 X 0.058 Galvanized Iron Profile Dimension, Powder Coated, Ss Ball Bearing Butt Hinges, Mortise Sash Lock With Handles,Mortise Dead Bolt,Latch, Panic Device Provided. -Main Door / Server Room Door , Fire Rated Door Providing And Fixing Steel Door Of Size As Mentioned Below With Tata Pravesh Brand -Constructed From 0.0012M Swg Gi Sheet. 0.046M Thk, Frame Of 0.1 X 0.058 Galvanized Iron Profile Dimension, Powder Coated, Ss Ball Bearing Butt Hinges, Mortise Sash Lock With Handles,Mortise Dead Bolt,Latch, Panic Device Provided. -Service Door , Providing And Fixing Of Toughened Glass Floor Over The Digital Diaply Flooring Using Ms Structure (80Mm X 80Mm X 4Mm Thick As Outer Section And 80Mm X 40Mm X 4Mm Thick As Inner Section) And Glass (8Mm St 167 Toughened Glass + 1.52Mm Clear Pvb + 8Mm St 167 Toughened Glass) Using Spacer Tape With All Other Necessary Accessories. And Need To Arrest 8Mm Fiber Cement Panel With Painting. The Cost Including Of Glass Loading, Fixing And Transport Charges. , Providing And Fixing Anodized/Powder Coated Aluminum Worksliding Doors With Extruded Built Up Standard Tubular And Other Sections Of Approved Made Confirming To Is 733 And Is 1285, Anodic Or Transparent Or Dyed To Required Shade According To Is:1868 (Minimum Anodic Coating Of Grade Ac 15), Fixed With Rawl Plugs And Screws, Or With Fixing Clips, Or With Expansion Hold Fasteners Including Necessary Filling Up The Gaps At Junctions, Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitered And Jointed Mechanically, Wherever Required Including Cleat Angle, All Necessary Hardware Fittings All Complete As Per Architectural Drawings And As Directed The Glass Should Be 5/6Mm Thick Toughened Glass Of Modi/ Saint Gobain Or Equivalent.Ss Mosquito Mesh Mesh Gap: 1.3Mm Opening Aperture, Wire Dia: 30 Swg Material As Per Ss: 2245 Material Grade: Aisi 304. The Cost Includes All Material Machinery Andlabour Including Scaffolding And Any Other Preparatory Work To Install And Complete And Clean As Directed By Engineer In Charge , Miscellaneous Providing And Fixing Of Glass Canopy Using Ms Structure (80Mm X 80Mm X 4Mm Thick As Outer Section And 80Mm X 40Mm X 4Mm Thick As Inner Section) And Glass (8Mm St 167 Toughened Glass + 1.52Mm Clear Pvb + 8Mm St 167 Toughened Glass) Using Spacer Tape With All Other Necessary Accessories. And Need To Arrest 8Mm Fiber Cement Panel With Painting. The Cost Including Of Glass Loading, Fixing And Transport Charges. - Over Main & Service Doors , Monkey Ladder Height: 3.5M / Width: 0.6M , Invisible Grill: 3Mm Dia : @250Mm C/C- Staircase And Parapet , Sub Head B - Electrical Works Part-A Wiring Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Of 25Mm Pvc Conduits, Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , (Xii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 12M Length) , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Ofmetal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (The Item Excluding Cost Of 19Mm/25Mm Dia Pvci.E, Point Wiring In The Existing Conduits) (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , (Xii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 12M Length) , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Of 25Mm Frls Conduits, Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Of 25Mm Ms Conduits, Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , (Xii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 12M Length) , Power Receptacles Supply, Installation, Testing And Commissioning Of Power Points By Providing Following Switches/Sockets, Mounted Flush To The Walls Usingms Boxes, Inner Plates, Front Plate, Modular Switches And Sockets With All Wiring Accessories. (I) One 6A Dependent 5-Pin Socket Point Controlled By One No Of 6A Switch. (Switch & Socket Are Mounted In A Dependent Switch Box) , (Ii) One 6A Independent 5-Pin Socket Point Controlled By One No Of 6A Switch. (Switch & Socket Are Mounted In An Independent Switch Box White Colour) , (Iii) One 6A Independent 5-Pin Socket Point Controlled By One No Of 6A Switch. (Switch & Socket Are Mounted In An Independent Switch Box Black Colour) , (Iv) One 6A One Way Independent 5-Pin Socket With Terminations , (V) One 6A One Way Dependent/Independent Switch With Terminations , (Vi) One 6A/16A 5-Pin Socket Point Controlled By One 16A Switch With Indicator. (Switch & Socket Are Mounted In An Independent Switch Box) , (Vii) Two Nos 6A/16A 5-Pin Socket Point Controlled By Two Nos 16A Switch With Indicator. (Switch & Socket Are Mounted In An Independent Switch Box White Colour) , (Viii) Two Nos 6A/16A 5-Pin Socket Point Controlled By Two Nos 16A Switch With Indicator. (Switch & Socket Are Mounted In An Independent Switch Box Black Colour) , (Ix) Two Nos Of 6A Independent 5-Pin Socket Points Controlled By Two Nos Of 6A Switches. (White Colour) , Supply, Installation, Testing And Commissioning Of Power Points By Providing Following Switches/Sockets, Mounted Flush To The Walls Usingms Boxes, Inner Plates, Front Plate, Modular Switches And Sockets With All Wiring Accessories. (I) 2 Module , (Ii) 3 Module , (Iii) 4 Module , (Iv) 6 Module , (V) 8 Module , (Vi) 12 Module , (Vii) 16 Module , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Main Circuit Wiring From Panel/Db To Dbs, Db To Switch Boxes And Switch Box To Other Switch Boxes Using 1100V Grade Pvc Insulated Multistranded Frls Copper Wires, To Be Drawn Through Existing Laid Conduits. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (The Item Excluding Cost Of 25Mm Dia Frls Pvc/Ms Conduit-Circuit Wiring In The Existing Conduits) (I) 3 Runs Of 1.5 Sq.Mm. Frls Copper Wiring In The Existing Laid Frls Pvc/Ms Conduits. (This Item Will Be Considered Only Where The Point Wiring Exceeds The Mentioned Length) , (Ii) 2 Runs Of 2.5 Sq.Mm. & 1 Run Of 1.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Iii) 2 Runs Of 4 Sq.Mm. & 1 Run Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Iv) 2 Runs Of 6 Sq.Mm. & 1 Run Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (V) 4 Runs Of 4 Sq.Mm. & 2 Runs Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Vi) 4 Runs Of 6 Sq.Mm. & 2 Runs Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Vii) 4 Runs Of 10 Sq.Mm. & 2 Runs Of 4 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , Supply And Installlation Of Surface/Recessed Type Frls Pvc, Rigid/Flexible, Conduits Of The Following Sizes With Required Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), Clamps, Screws, Bolt & Nuts And Necessary Fixing Accessories Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 20Mm Dia 2Mm Thick Rigid Pvc Conduits. , (Ii) 25Mm Dia 2Mm Thick Rigid Pvc Conduits. , (Iii) 20Mm Dia 1.6Mm Thick Rigid Pvc Conduits. , (Iv) 25Mm Dia 1.6Mm Thick Rigid Pvc Conduits. , (V) 20Mm Dia 2Mm Thick Rigid Frls Pvc Conduits. , (Vi) 25Mm Dia 2Mm Thick Rigid Frls Pvc Conduits. , (Vii) 20Mm Dia 1.6Mm Thick Rigid Frls Pvc Conduits. , (Viii) 25Mm Dia 1.6Mm Thick Rigid Frls Pvc Conduits. , (Ix) 20Mm Dia 1.6Mm Thick Rigid Ms Conduits. , (X) 25Mm Dia 1.6Mm Thick Rigid Ms Conduits. , Part-B- Distribution Board Supply, Installation, Testing And Commissioning Of Following Ways Of Surface/Flush Mounting, Double Door Phase Segregation Seven Segment Type Tpn Mcb Dbs Of Sheet Steel, Powder Coated, Ip42 Protection, Metal Door And Cable End Box Etc. The Item Including Terminal Connectors For All Incoming And Outgoing Circuits, Duly Pre-Wired With Suitable Size Of Frls Pvc Copper Wires Upto Terminal Blocks, Tinned Copper Bus Bar Of Suitable Rating, Neutral Links, Earth Bars, Detachable Gland Plate, Interconnections By Using Crimping Type Ferrules & Copper Lugs, And Engraving Of Laminated As-Built Circuit Drawings In The Door Inside Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 4Way , (Ii) 6Way , Supply, Installation, Testing And Commissioning Of Following Ways Of Surface/Flush Mounting, Vtpn Mcb Dbs Of Sheet Steel, Powder Coated, Ip43 Protection, Metal Door And Cable End Box Etc. The Item Including Terminal Connectors For All Incoming And Outgoing Circuits, Duly Pre-Wired With Suitable Size Of Frls Pvc Copper Wires Upto Terminal Blocks, Tinned Copper Bus Bar Of Suitable Rating, Neutral Links, Earth Bars, Detachable Gland Plate, Interconnections By Using Crimping Type Ferrules & Copper Lugs, And Engraving Of Laminated As-Built Circuit Drawings In The Door Inside Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: 12 Way , Supply, Installation, Testing And Commissioning Of Following Ways Of Surface/Flush Mounting, Spn Mcb Dbs Of Sheet Steel, Powder Coated, Ip43 Protection, Metal Door And Cable End Box Etc. The Item Including Terminal Connectors For All Incoming And Outgoing Circuits, Duly Pre-Wired With Suitable Size Of Frls Pvc Copper Wires Upto Terminal Blocks, Tinned Copper Bus Bar Of Suitable Rating, Neutral Links, Earth Bars, Detachable Gland Plate, Interconnections By Using Crimping Type Ferrules & Copper Lugs, And Engraving Of Laminated As-Built Circuit Drawings In The Door Inside Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 8Way , (Ii) 12Way , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Single Phase / Three Phase C Curve, 10Ka Mcbs To Be Fixed In The Existing Mccb/Mcb Dbs Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 6A To 32A Single Pole Mcb , (Ii) 40A To 63A Singl Pole Mcb , (Iii) 6A To 32A Singl Pole Neutral / Double Pole Mcb , (Iv) 40A To 63A Singl Pole Neutral / Double Pole Mcb , (V) 6A To 32A Triple Pole Mcb , (Vi) 40A To 63A Triple Pole Mcb , (Vii) 6A To 32A Four Pole Mcb , (Viii) 40A To 63A Four Pole Mcb , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Three Phase 18Ka Adjustable Thermal Magnetic Release Type Mccbs To Be Fixed In The Existing Mccb Dbs Or Panels Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer:100A Four Pole Mccb , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Single Phase / Three Phase Rccbs To Be Fixed In The Existing Mccb/Mcb Dbs Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 25A Double Pole Rccb, 30Ma , (Ii) 63A Four Pole Rccb, 30Ma , (Iii) 40A Four Pole Rccbo, 30Ma , (Iv) 32A Four Pole Rccbo, 300Ma , (V) 63A Four Pole Rccb, 300Ma , Supply And Installation Of Blanking Plates In The Existing Mccb/Mcb Dbs Or Enclosures Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Single Phase / Three Phase Rccbs To Be Fixed In The Existing Mccb/Mcb Dbs Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) Double Pole Enclosure For Mcbs , (Ii) Four Pole Enclosure For Mcbs , Supply, Installation, Testing And Commissioning Of Following Weather Proof Boxsuitable For Independent Mounting Of Mcb/Mccb/Rccbs Complete With All Necessary Fixing Accessories Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) Double Pole Enclosure For Mcbs , (Ii) Four Pole Enclosure For Mcbs , Supply, Installation, Testing And Commissioning Of Following Weather Proof Boxsuitable For Independent Mounting Of Mcb/Mccb/Rccbs Complete With All Necessary Fixing Accessories Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 100 X 100 X 50 Mm , (Ii) 150 X 150 X 50 Mm , (Iii) 300 X 300 X 50 Mm , Part-C Luminaires And Fixtures Installing, Testing And Commissioning Of The Following Luminairesincluding Driver, Connecting Wire,Clamps, Screws, Bolt & Nuts, Down Rods, Required Connector Block Terminals And Necessary Fixing Accessories Etc. (I) 230V, 18W Led Spot Light Luminarie. , (Ii) 230V, 15W Led Down Light Luminaire , (Iii) 230V, 15W Led 8 Profile Light Luminaire , (Iv) 230V,15-20W/Meter Led Strip Light Fittings. , Installing, Testing And Commissioning Of Wall Mounted Fan , With Mounting Frame, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Part-D Lt Panels Supply,Installation, Testing And Commissioning Of 415V Cubical Type, Fully Compartmenalised, Floor Mounted Type Lt Switch Boards Fabricated With 14G Crca Sheet, Powder Coated With Siemens Grey (Ral 7032) After Seven Tank Process And Complete With Welded & Bolted Design And All Incoming & Outgoing Switch Gears As Per The Following.Suitable Aluminuim Busbars, Control Wiring, Control Fuses, Seperate Metering Compartment (Incoming) With Multi Function Meter, Phase Indications With Necessary Control Wiring. Safety Features And Items Including Necessary Earthing Throughout The Bottom Length, 6 Sq.Mm Frls Copper Wire Interconnections For Compartment Earthing, Complete Copper Control Wiring With Crimping Type Ferrules, Copper Lugs, Proper Engravation On Each Compartment Etc.The Switch Boards Shall Be Cpri Approved Of Factory Assembled And Tested. All The Mccbs With Micro Processor/Thermal Magnetic Releases And Have Rotary Handle Mechanism & Spreader Current Density Not More Than 0.7A/Sq.Mm For Aluminium Bus Bar. Neutral Current Rating Is Half The Phase Currentall Busbars Shall Be Fixed With Standard Space Clearance And With Colour Coated Heat Shrinkable Pvc Sleeves With Dmc/Smc Bus Bar Supports And Suitable Earth Bus (25 X 3Mm Cu).The Cable Entry Shall Be From The Bottom/Top As Per Site Requirement.The Item Including Cost Of Ms Base Frame Of 75Mm Height, 3.15Mm Sheet Steel Or 40X40x6mm Ms Angle For Load Bearing Members, Lifting Hooks, Steel Support Structure Required For Erection And Its Painting, Minor Civil Works, Vendor Drawings, Necessary Safety Clearance From Statutory Authorities, Panel Approval From Tneb Till Obtaining Final Power Supply, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer.The Contractor Shall Submit General Arrangement & Control Wiring Drawings And Get Approval From Site Engineer/Consultant Before Commence The Fabrication Works. Sub Panelincomer: (I) 100A 4P On-Load Auto Change Over Switch With Control Mcbs, With Rotary Handle Mechanism & Spreader And Phase Indications Etc. - 1 No. (Ii) 100A, Tpn, 25Ka, Mccb With Adjustable Thermal Magnetic Releases And Rotary Handle Mechanism & Spreader- 1 No , Metering:(I)3 Nos-Ct Ratio 100/5A,Cl:1.0 Tape Insulated Type With Suitable Sorting Links..(Ii) 3 Nos-Ct Ratio 100/5A,Cl:1.0, 15Va Tape Insulated Type With Suitable Sorting Links Power Factor Sensingrelay1 Set – Indication Lamps For R,Y,B, Breaker On(Red), Breaker Off (Green), Breaker Trip (Amber) With Control Mcbs.Bus Bar:100A, Tpn, 25Ka, For 1 Sec Aluminium Bus Bar (I)Phase: Current Density Not More Than .7A/Sq.Mm(Ii)Neutral: Half Of The Phase Current (0.5 X Phase) (Iii) Earth: 25X3mm Copper Flatoutgoing:(I)63A Fp 10Ka Mcb C Curve- 3 Nos(Ii) 40A Fp 10Ka Mcb C Curve- 1 No(Iii)32A Fp 10Ka Mcb C Curve- 3 Nos (Iv) 16-32A Dp 10Ka Mcb C Curve- 1 Nonote:All Outgoing Feeders Should Be Provided In Individual Compartment , Supply, Installation, Testing And Commissioning Of 415V Cubical Type, Non Compartmenalised, Floor/Wall Mounted Type Automatic Power Factor Correction Panel Board Fabricated With 14G Crca Sheet, Powder Coated After Seven Tank Process And Complete With Bolted Design And The Provisions As Follows. Gas Filled Cylindricalheavy Duty Capacitors (App Type) Of 10Kvar . The Switch Boards Shall Be Cpri Approved Of Factory Assembled And Tested.The Cable Entry Shall Be From The Bottom/Top, Suitable Aluminuim Busbars, Control Wiring, Control Fuses, Seperate Metering Compartment, Phase Indications, Safety Features And Items Including Necessary Earthing Throughout The Bottom Length, 6 Sq.Mm Frls Copper Wire Interconnections For Compartment Earthing, Complete Copper Control Wiring With Crimping Type Ferrules, Copper Lugs, Proper Engravation On Each Compartment Etc. Also The Cost Inclusive Of Ms Base Frame, Steel Support Structure Required For Erection And Its Painting, Minor Civil Works, Vendor Drawings, Necessary Safety Clearance From Statutory Authorities, Panel Approval Fromceig/Tneb/Tangedco Till Obtaining Final Power Supply, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. All The Mccbs With Micro Processor / Thermal Magnetic Releases And Have Rotary Handle Mechanism. Each Compartment/Section Shall Have Exhaust Fans The Incoming Shall Have Metering, Ammeter & Voltmeter With Selector Switches, Ryb Indication Lamp With Control Mcbs And 8 Stage Apfc Relay Etc. Each Outgoings Shall Have Set Of Capacitor Duty Contactors, Set Of On/Off Indication Lamps And Set Of On/Off Push Button Etc. Incomer:(I)32A 4P 10Ka Mcb C Curve- 1 No Bus Bar:100A, Tpn, 25Ka, For 1 Sec Aluminium Bus Bar(I) Phase: Current Density Not More Than 0.8A/Sq.Mm(Ii)Neutral: Half Of The Phase Current (0.5 X Phase) (Iii) Earth : 25 X 3 Mmcopper Flat Outgoing:(I)3 Kvar Feeder Fitted With 25A Tp 10Ka Mcb - 1 No. (Ii) 2 Kvar Feeder Fitted With 20A Tp 10Ka Mcb - 1 No.(Iii) 1 Kvar Feeder Fitted With 20A Tp 10Ka Mcb - 5 Nos , Lt 3 Phase Metering Panel Lt 3 Phase Metering Panel With Tpn Fuse And Metering Provisions For 1 No As Per Tneb Standard With Double Earthing.100A,Rwf Fuse (3Nos) + Neutral Link- 1 Set 100A, Fp, 25Ka, Mccb With Adjustable Thermal Magnetic Releases And Rotary Handle Mechanism & Spreader - 1 No. , Part-Elt Cabling Supply, Laying, Testing And Commissioning Of Following 1.1Kv Grade Multicore Aluminium Conductor Xlpe/Pvc Insulated Gi Round(Upto 10Sqmm) / Flat(16Sqmm And Above) Armoured Pvc Sheathed Cables (Without Any Cable Joint) Drawn Through Tray Or Steel Supports Or Clamping On The Ceiling/Wall Or Pre-Excavated / Pre-Formed Trenches Or Gi Pipe Sleeves / Hume Pipes With Suitable Clamping Arrangement And Fixing Accessories, Cable Routemarkers, Cable Ties, Identification Tags Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 3.5C X 50 Sq.Mm Aluminium Xlpe Cable , (Ii) 3.5C X 35 Sq.Mm Aluminium Xlpe Cable , (Iii) 4C X 16 Sq.Mm Aluminium Xlpe Cable , (Iv) 4C X 10 Sq.Mm Aluminium Xlpe Cable , (V) 4C X 6 Sq.Mm Aluminium Xlpe Cable , Supply, Laying, Testing And Commissioning Of Following 1.1Kv Grade Multicore Copper Conductor Xlpe/Pvc Insulated Gi Round(Upto 10Sqmm) / Flat(16Sqmm And Above) Armoured Pvc Sheathed Cables (Without Any Cable Joint) Drawn Through Tray Or Steel Supports Or Clamping On The Ceiling/Wall Or Pre-Excavated / Pre-Formed Trenches Or Gi Pipe Sleeves / Hume Pipes With Suitable Clamping Arrangement And Fixing Accessories, Cable Routemarkers, Cable Ties, Identification Tags Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 4C X 10 Sq.Mm Copper Xlpe Cable , (Ii) 4C X 6 Sq.Mm Copper Xlpe Cable , (Iii) 4C X 4 Sq.Mm Copper Xlpe Cable , Supply And Termination Of The Following Sizes Of 1.1Kv Xlpe/Pvc Insulated Al/Cu Conductor Cables With Single Compression Brass Cable Glands And Tinned Copper Lugs Including Gland Earth Clips, Adequate Size Of Bare Copper Wire Connecting To The Main Bus Bars Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 3.5C X 50 Sq.Mm Aluminium Xlpe Cable , (Ii) 3.5C X 35 Sq.Mm Aluminium Xlpe Cable , (Iii) 4C X 16 Sq.Mm Aluminium Xlpe Cable , (Iv) 4C X 10 Sq.Mm Aluminium Xlpe Cable , (V) 4C X 6 Sq.Mm Aluminium Xlpe Cable , (Vi) 4C X 10 Sq.Mm Copper Xlpe Cable , (Vii) 4C X 6 Sq.Mm Copper Xlpe Cable , (Viii) 4C X 4 Sq.Mm Copper Xlpe Cable , Supply And Erection Of Following Size Of Hot Dip Gi Ladder Type Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Right Angles, Cross Members And Other Accessories Etc. The Item Including Cost Of Steel Support Structures At Every 0.6M/1M Intervels As Required For Suspend From The Ceiling Or Supported From Walls With Ms Suspenders/Brackets And All Complete With Painting/Powder Coating Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. (I) 150 X 50 X 2Mm , (Ii) 200 X 50 X 2Mm , (Iii) 300 X 50 X 2Mm , Supply And Erection Of Following Size Of Perforated Gi Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Right Angles, Cross Members And Other Accessoriess Etc. The Item Including Cost Of Steel Support Structures At Every 0.6M/1M Intervels As Required For Suspend From The Ceiling Or Supported From Walls With Ms Suspenders/Brackets And All Complete With Painting/Powder Coating Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. (I) 150 X 50 X 2Mm Without Cover , (Ii) 200 X 50 X 2Mm Without Cover , (Iii) 300 X50 X 2Mm Without Cover , (Iv) 450 X50 X 2Mm Without Cover , Laying Cables Buried Underground At 750Mm. From Fgl Including Necessary Excavation, Supply And Placingof Cable Markers And Backfilling In Compacted Layers, All Complete As Per Specifications, Drawings And /Or As Directed By The Engineer. , Supply, Installation Of Following Sizes Of Heavy Duty Pvc Pipe For Cable Crossing Of Basement Cable Entry & External Lights And The Like, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 50Mm Dia , (Ii) 100Mm Dia , Supply, Installation Of Following Sizes Of Hume Pipes For Cable Crossing Of Drains, Roads, Sanitary And Water Supply Lines And The Like, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. 150Mm Dia , Supply And Erection Of Following Size Of Pvc Trunking Channelincluding Horizontal And Vertical Bends, Joints,Tees, Angles, Cross Members And Other Accessoriess Etc. The Item Including Cost Of Support Clamping At Every 0.6M/1M Intervels As Required For Wall / Floor Mounting System And All Complete Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. (I) 50 X 80 Mm , (Ii) 50 X 105 Mm , Part-F Diesel Generator Supply, Unloading & Handling, Erection, Testing And Commissioning Of Following Ratings Of Dg Set With Standard Accessories Coupled To Alternator, 3 Phase, 4 Wire, 0.8 Pf (Lag), 415 V Mounted On A Channel Iron Base Frame With Foot Mounting Avm Pads, Fuel Tank (In Built), Charged Battery With Leads, Silencer Along With Exhaust Stack Raised Above Terrace Level(Avg 30M), Composite Type Acoustic Enclosure And Standard Control Panel. The Governor Shall Be Of Electronic & Mechanical Type And The Items Including Erection Of Amf Panel And Complete With Necessary Control Wiring/Cabling, Metering, Indication Lamps And Fixing Accessories Etc. 30Kva , Part-G Ups/Inverter Supply, Erection, Testing And Commissioning Of 1 Phase, 230 V, 1Kva 1P -In 1P Out Ups With Suitable Bcb (Battery Circuit Breaker), Filters, Suitable Tublers Batteries With 30Minutes Backup With Necessary Fixing Accessories Etc. , Supply, Erection, Testing And Commissioning Of 1 Phase, 230 V, 3Kva 1P -In 1P Out Ups With Suitable Bcb (Battery Circuit Breaker), Filters, Suitable Tublers Batteries With 30Minutes Backup With Necessary Fixing Accessories Etc. , Part-H Earthing Supply, Installation, Testing And Commissioning Of Earth Station Comprising Of 50Mm Outer Diameter And 3 Meter Length Of Copper Safe Earth Electrode, Including Approved Clamps, Bolts & Nuts, 450M X 450Mm Brick Masonary Chamber, Heavy Duty Ci Cover, Homogeneous Layers Of Earth Enhancing Backfilling Materials (Bentonite/Fly Ash) Are Placed Around The Earth Pipe As Per Standards (Is 3043), The Items Including Cost Of Excavation, Backfilling Of Earth Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Installation, Testing And Commissioning Of Earth Station Comprising Of 50Mm Dia 3 Meter Long Galvanised Iron Pipe Earth Electrode And 25X3mm Copper Flat, Including Approved Clamps, Bolts, Nuts, Special Backfill Compound (Bentonite/Fly Ash), 450Mm X 450Mm Brick Masonary Chamber, Heavy Duty Rcc / Ci Cover, Drilling Into All Types Of Earth And Rock, Any Excavation And Backfilling, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying, Testing And Commissioning Of Following Sizes Of The Earth Conductors For The Electrical System Which Including Cost Of Supply And Fixing Of Saddles, Insulators, Clamps, Screws, Bolt & Nuts And Providing Earth Work Of 2 Depth, Sleeves Wherever Required Etc., All Complete As Per Specifications, Drawings And/Or As Directed By The Engineer. (I) 25X6mm Hot Dip Gi Flat. , (Ii) 25X3mm Copper Flat. , (Iii) 300Mm Long 25X6mm Hot Dipped Cu Flat. , (Iv) 25X3mm Hot Dip Gi Flat. , (V) 8 Swg Copper Wire. , (Vi) 10 Swg Copper Wire. , Part-I Safety Accessories Supply And Installation Of The Following Safety Accessories To Be Installed In The Electrical Panel Room. First Aid Box. (Is Marked - As Per Standard Requirement) , Supply And Fixing Of 6 Kgs Co2 Type (Isi Marked) Fire Extinguisher Complete With All Clamps And Hardwares Etc. , Supply And Position Of 1.1 Kv Grade 2Mtr X 1Mtr Rubber Mat For Lt Switch Boards To Suit The Switch Board. (As Per Standard & Isi Marked) , Supply And Fixing Of Shock Treatment/First Aid Treatment Chart In Tamil, Hindi And English, Complete With Necessary Fixing Accessories Etc. , Part-J Telephone System Supply And Fixing Of Rj-11Modular Type Outlet Mounted On Suitable Zinc-Passivated Metal Box For Telephone Complete With Metal Box, Front Plate, Screws And Fixing Accessories Etc.,The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same Incase Of Recessed Mounting And All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply And Fixing Of Rj-45 (Cat-6) Modular Type Outlet Mounted On Suitable Zinc-Passivated Metal Box For Telephone Complete With Metal Box, Front Plate, Screws And Fixing Accessories Etc.,The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same Incase Of Recessed Mounting And All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply And Laying Of High Quality Cat-6 Ethernet Lan Cable Preferably With Fr Pvc Insulation To Be Laid In Existing Tray/Raceways/ Conduit From Individual Telephone To Network Jack/Switch/Patch Panel/Hub Located In The Communication Room. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying And Termination Of Following Sizes Of Telephone Cable Laid In Exitingconduit/Tray/Raceways From Krone Junction Box To Other Krone Junction Box/Epabx Etc.And All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. 2 - Pair Cable , 5 - Pair Cable , Supply And Fixing Of The Following Telephone Krone Type Junction Boxes Enclosed In Ms Box With Hinged Cover With Lock & Key Arrangements Etc.The Item Including Necessary Clamping And Making Good The Same In Case Of Recessed Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. 5 - Pair Kjb , Part-Kdata Networking System Supply And Fixing Of Rj-45 Modular Type Data Outlet (Cat-6A) Mounted On Suitable Zinc-Passivated Box Complete With Metal Box, Front Plate, Screws And Fixing Accessories Etc.The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply Andlaying Of High Quality Cat-6A Ethernet Lan Cable Preferably With Fr Pvc Insulation To Be Laid In Exisitng Tray/Conduit/Racewaysfrom Individual Data To Network Jack/Switch/Patch Panel/Hub Located In The Communication Room.All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying And Termination Of High Quality Armoured Optical Fiber (48 Fibers) Along With The All Accessories Connectors, Switches Etc , Fixing Of Modular Type Information Outlet (For Wi-Fi) With Necessary Fixing Accessories. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying And Termination Of 6 Pair Fibre Optic Cable Laid In Existing Conduit/Tray/Hume Pipe With The All Necessory Accessories As Required. , Supply, Laying And Termination Of Hdmi Cable Of 15 Meters In Length Laid In Existing Conduit/Tray/Hume Pipe With The All Necessory Accessories As Required. , Supply, Laying And Termination Of Hdmi Cable Of 15 Meters In Length Laid In 40Mm Pvc Pipe With The All Necessory Accessories As Required. , Supply, Fixing , Testing And Commissioning Of 24 Port Switch Patchpanelwith The All Necessory Accessories As Required. , Part-Lclosed Circuit Television System Supply, Laying And Termination Of High Quality Cat-6 Ethernet Lan Cable Preferably With Fr Pvc Insulation To Be Laid In Existing Pvc Pipe From Individual Cctv Camera Outlets To Network Jack/Switch/Patch Panel/Hub Located In The Communication Room. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supplying And Installing Wall Or Ceiling Mounted Outdoor Type Fixed Dome Ip Camera With 1/3” 4Mp Ps Cmos Image Sensor 4Mp@25/30Fps (2560 × 1440), Ir Range Of 30 Mtrs,. The Items Inclluding Necessary Fixing Accessories. , Supplying And Installing Wall Or Ceiling Mounted Indoor Type Fixed Dome Ip Camera With 1/3” 4Mp Ps Cmos Image Sensor 4Mp@25/30Fps (2560 × 1440), Ir Range Of 30 Mtrs,. The Items Inclluding Necessary Fixing Accessories. , Supply, Fixing And Termination Of High Quality Rack Mounted Type Patch Panel With One Number Of 16 Port Poe Network Switch, Fixing Frames, Links And Interconnections, Necessary Accessories Etc., All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Fixing And Termination Of High Quality Floor Mounted Type 6U Floor Mountable Powder Coated Rack With 3X5a Power Manager, 1 Position Fan, Min 1 Nos Of Shelf, Front Glass Double Door With Lock & Key With Suitable Network Port Switch, Fixing Frames, Links And Interconnections, Necessary Accessories Etc., All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supplying And Installing Of 16 Channel Network Video Recorder With Max 320Mbps Incoming Bandwidth Smart H.265+/H.265/ Smart H.264+/H.264/Mjpeg Up To 12Mp Resolution Preview And Playback Support 8 Sata Hdds Up To 10Tb Each, 4 Usb (2 Usb3.0, 2Usb2.0) 2 Hdmi / 2 Vga Simultaneous Video Output Support Multi-Brand Network Cameras Support Raid 0/1/5/10 Mobile Software: Icmob, Gcmob Cms Software: Kvms Pro. The Items Including Supply Of 4Tb Hard Disk, Connectors, Pins And Providing Complete Configuration Etc. , Supplying And Installing Of Power Supply Unit Along With Necessary Battery Backup, Suitable For 1 Nos. 16 Channel Network Video Recorder System. , Supplying And Installing Of 32 Led Colour Monitor. , Part-M-Miscellaneous Liasioning With Tneb Including Submission Of Application & Documents For Obtaining Required Additional Demand Power. (Appx. Cost) , Hvac System Supply, Installation,Gas Charging, Testing And Commissioning Of Modulating Outdoor Units, With Multi Scroll/Rotary Compressorswith One Capacity Controlling Compressor, Special Pre-Coated Fins, Panel, Corrosion Resistant (Suitable For Seaside Installation) Coated Condenser, Inverter Based Condenser Fan Mounted As Indicated In The Drawing, Electrical & Microprocessor Panel, Isolating Valves And All The Necessary Accessories For Proper Functioning Of The Units, Having Following Approximate Capacities. Indicate For All Port Charges, Port Handling Charges, Other Local Duties, Loading, Transportation /Insurance Up To Site, Octroi Charges And All Other Taxes And Incidentals Complete Till Delivered At Site. Customs Duty And Countervailing Dutyfor The Above Imported Equipment. Receiving At Site Above Imported Equipment, Unloading, Storing, Handling Hoisting, Installing In Position, Effecting Connections, Anchoring, Grouting Testing And Commissioning Above Equipment Including Supplying And Installing All Necessary Indigenous Accessories As Required To Complete The Installationnote : Fins And Copper Tubes Of Air Cooled Condenser Alongwith Copper Tubing / Piping With All Joints And U-Bends Exposed To Coastal Areas Corrosive Atmosphere / Aggressive Ambient, Shall Be Painted With Special Orrosion Prevention Coating Either In Factory Or At Site. 14 Hp Odu Units , Supply,Erection, Testing And Commissioning Of Vrf Based Ductable / Fcu Type Indoor Units Complete With Remote And All Accessories,Vibration Isolators & Supports. The Each Indoor Units Shall Be With Potentilal Free Contactor To Connect With Bms. (I) 5.0 Tr With Wired Remote- Ductable , (Ii) Ceiling Mounted Fan Coil Unit - 2.56 Tr With Wired Remote- Fcu , (Iii) Cassette Type Unit - 1.32 Tr With Wireless Remote , (Iv) Hiwall Type Unit - 1.0 Tr With Wireless Remote , Supply, Installation., Testing And Commissioningof Centralized Remote Controller , Supply,Erection , Testing And Commissioning Of All Refrigerant Joints ( Necessary Filling Of Refrigerant Gas In Circuits, Ref. Pipe Pressure Test Etc.). , Supply, Installation, Testing And Commissioning Of Hiwall Splitunit Air Conditioner Comprising Indoor And Out Door Unit Interconected At Field By Refrigerant Piping. The Refrigerant Shall Be Working Onnon Cfc Based R407c/R410 A/R134a Refrigerant. The Indoor Unit Shall Comprise Multirow Dx Cooling Coil, Nylon Pre-Filter, Centrifugal Blower With Drive Motor Mounted In An Aesthetically Pleasing High Quality Plastic Casing. The Out Door Unit Shall Comprise, Rotary / Scroll Compressor/S, Condenser Coil, Propeller Fan, Ip55 Motor All Housed In A Powder Coated Casing. The Fan Shall Be Selected For Low Noise And Shall Be Provided With Fan Guard. The Unit Set Shall Be Supplied With Apower Cum Control Panel Incorporating All Switchgear Required For The Machines Functioning Along With Over Load Relay Etc. The Price Shall Include Corded / Cordless Remote Controler, Installation Of The Units As Per Site Conditions And Charging Of Necessary Refrigerant & Oil If Required. Suitable Contactor To Enable Trip On Receiving Fire Alarm Signal To Be Provided. 1.0 Tr Hiwall Split (Server Room Standby Unit) , Supply, Installation, Testing And Commissioning Ofsoftron Refrigerant Copper Piping With Nitrile Rubber Tubular Insulationwith 13/19Mm Thicknesswith Glass Cloth And Poly Shield Coating Between Indoor To Outdoor Unitsand Supporting Arrangements Etc… Suitable Size For Above Mentioned Dx Hi-Wall Split Units . , Supply, Installation, Testing And Commissioning Of Hard/Soft Drawn Soft Refrigerant Piping Along With Insulation And Supports, Between Indoor & Outdoor Units Duly Insulated As Per Specifications.The Brazing To Be Carried Out With Bleeding Of Nitrogen. The Copper Pipe To Be Insulated With 19 Mm Thick / 13 Mm Thick Nitrile Rubber Sleeves Or Sheet Shall Be Properly Supported With Hanger And Exposed Piping Shall Be Properly Supported In Cable Tray. (I) 41.3 Mm , (Ii) 34.9 Mm , (Iii) 28.6 Mm , (Iv) 22.2 Mm , (V) 19.1 Mm , (Vi) 15.9 Mm , (Vii) 12.7 Mm , (Viii) 9.52 Mm , (Ix) 6.5 Mm , Supply And Laying Of 2C X 1.5 Sqmm. Control Cabling & Earthing As Per Specifications Between Out Door Unit & Indoor Units. The Cables Should Be Cross Linked Polythene Insulated, Armoured Copper Cabling With A Low Smoke And Flame Sheath . Power Supply (3 Phase 415 Volts Will Be Made Available Near Outdoor Units. Contractor To Provide Panel For Onward Power / Control Supply To Outdoor Units Andpower Supply Single Phase Will Be Made Availabe Near Indoor Units Contractor To Provide Power/Control Supply To Indoor Units, Supports, Trays Etc. , Supply And Erection Of 200(W) X 75(H) Size Of Flat Gi Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Right Angles, Cross Members And Other Accessoriess Etc. The Item Including Cost Of Steel Support Structures At Every 0.6M/1M Intervels As Required For Suspend From The Ceiling Or Supported From Walls With Ms Suspenders/Brackets And All Complete With Painting/Powder Coating Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. , Machine Made Gss Ducting With Flanges, Neoprene Gaskets, Factory Made Supports, With Black Painting As Per Specifications (Factory Made With Ductmate Flanges) (I) 24 G Gi Ducts , (Ii) 22 G Gi Ducts , Supply And Installation Of Thermal Insulation 13Mm Thk Closed Cell Nitrile Rubber With Suitable Adhesive As Per Specification , Supply And Installation Of Accoustic Insulation 10Mm Thk Open Cell Nitrile Rubber With Suitable Adhesive As Per Specification , Supply And Installation Of 6 Ht Cont. Al. Powder Coated Grill For Supply And Return Air For Ductable Units , Supply And Installiion Of Gi Collar Damper 600 X150 Mm. , Supply And Installation Of Aluminium Powder Coated 3 Slot Diffuser With Hidden Mist Damper And Fixing Arrangements Etc… , Supply And Installation Of Aluminium Powder Coated Fresh Air Louver With Bird Screenanddamper And Fixing Arrangements Etc… 200 X 200 Mm , Supply And Installation Of Fire Retardant Canvass Connection , Providing And Fixing In Position The Followingupvc Drain Pipes Cut To Required Lengths And Installed With All Screwed Joints, And Providing And Fixing In Position The Necessary Elbows, Tees And Reducers As Per Specifications And Shall Be Insulated With 6Mm Thick Nitrile Rubber. (I) 25 Mm , (Ii) 32 Mm , Supply, Installation, Testing And Commissioning Of Poly Shield Coating With Glass Wool Packing For Weather Proof , Fire Fighting System Supply, Install, Test And Commission Of Boosterpump Terrace Pump Located At Terrace Level, Capacity: 450 Lpm At 35 Mtr. With Pressure Of 3.5Kg / Sq.Cm At The Top Most Hydrant, Complete Head, Horizontal Centrifugal Pump With Bronze Impeller, Ss Shaft, Mechanical Seal,Coupled To 10Hp,2900 Rpm, Tefc, Squirrel Cage Induction Motor Complete Withm.S. Base Frame, Anti Vibration Pad, Foundation Bolts, Pressure Gauge, Pressure Switchwith Drain Valve,And All Other Necessary Fixing Accessories. , Supply, Erection, Testing And Commissioning Ofc Class M.S Heavyfor Downcomer System As Per Is : 1239 For Pipes With Welable Fittings, Valves Necessary, All Structural Supports And Accessories.The Quoted Rate Shall Be Includes One Coat Of Primer And Two Coat Enamel Paint Of Approved Colour And Also Chasing / Chipping Walls Making Bore Hole In Walls / Floor And Making Them Good With Filler Material And Finished In Cement Mortar Etc. Complete In All Respect. (I) 100Mm Nb , (Ii) 80Mm Nb , (Iii) 25Mm Nb , Supply, Erection, Testing Andcommissioning Of `Fire Hose Cabinet (Fhc) In Size Of 750Mm X 900 Mm X 250 Mm.Hinged Door Shutter And Frame And Fabricated Out Of 14 Swg Sheet Steel, Fitted With 4Mm Thick Toughned Glass With Rubber Beeding In The Front Including Finishing With Powder Coat Painting Complete. The Rate Shall Be Inclusive Of Stand For Mounting, All Fasteners Etc, And Cabinet Shall Be Powder Coated Finish Of Red Colour Both Inside And Outside. , Single Headed Hydrant Valve As Per Is 5290, Made Of Gun Metal With 63 Mm Dia Instantaneous Outlet Of 80 Mm Dia Fanged Inelt ,Blank Caps , Chain And Hand Wheels Etc Complete. , 15 M Long, 63Mm Dia Rrl Hose With Instantaneous Couplings And Hoses Shall Be Stored Inside The Hose Cabinet. , 1 No. Gun Short Branch Pipe With Nozzle. , Fire Hose Reel Drum (As Per Isi)Wall Mounted, Swinging Type 18 Swg Ms Sheet, Fitted With 19 Mm Dia X 36 M Long, High Pressure Hose With 5 Mm Outletnozzle With Shut Off Valve (Is: 884-1969) , One No 25Mm Dia Ball Valve , Supply, Fixing, Testing And Commissioning Of Fire Brigade Inlet (Pumping In Breech) Connection, Having Gunmetal Body With 1 Nos. 63 Mm Size Gunmetal Male Instantaneous Inlets (With Nrv), And 100 Mm Size Flanged Outlet, Suitable For Connection To Dry Riser Piping. Fire Brigade Inlet Body Shall Be Provided With Drain Valve. Fire Brigade Inlet Connection Shall Be Isi Approved , Supply, Erection, Testing And Commissioning Of Slimseal Typebutterflyvalves Withshperoidalgraphite Irondisc(Sg Iron), With Nitrile Rubber Sealand Tested Topn 16 Including A Set Of Suitable Gi Flanges, As Per Bs 10 Table - 1, Bolts, Nuts Gi Washers, Neoprene Rubber Gaskets Etc., Complete. 100Mm Nb , Supply, Erection, Testing And Commissioning Of Dual Plate Non-Return Valves With Ci Body &Upto 125Nb Pn 16 Including A Set Of Suitable Ms Flanges, As Per Bs 10 Table - 1, Bolts, Nuts Gi Washers, Neoprene Rubber Gaskets Etc., Complete. 100Mm Nb , Supply, Erection Testing & Commissioning Of Pot Strainer / Y Strainer With Ci Bodytested Topn 16 Including A Set Of Suitable Gi Flanges Rate Shall Include For Rubber Insertion, Bolts, Nuts Msflanges.100Mm Nb , Supply, Erection, Testing And Commissioning Of 25Mm Dia Air Release Valve. The Rate Shall Be Inclusive Of Accessories.25Mm Dia Air Release Valve , Supply, Installation, Testing And Commissioning Of Terrace Fire Pump Panel Withtype-2 Co-Ordination Dol Starters For The Booster Pump And Complete With Auto/Manual Switch, Timers, Rotary Switches, Indication Lamps, Enclosure Being Vermin & Dust Proof (Ip65), Necessary Alarms, Push Buttons, Etc. The Panel Shall Also Be Provided With Industrial Hooter For Alarm And Necessary Suitable Relays Shall Be Provided - 450 Lpm Pump , Automatic Detection And Manual Fire Alarm System Main Control Panel: Supply, Installation, Testing & Commissioning Of Microprocessor Based Intelligent Analogue Addressable, Modular,Expandable, Networkable, 02- Loopfire Alarmcontrol Panel With Minimum 640 Character Lcd Display, Multiple Access Levels, Event History File In Nos.N-Volatile Memory (Eeprom). The Panel Shall Support Programmable Relay For Controlling Lifts, Staircase Pressurizations Fans, Lift Shaft & Lift Lobby Pressurization Fans, Toilets Exhaust Fans, Ventilation Fans At Fire Pump Room, Monitoring Of Fire Hydrant Pump Controlled By Powerful Boolean Logic Equation. The Panel Shall Have 240 Volts Ac Power Supply, Automatic Battery Charger, 24 Volts, Sealed Lead Acid Maintenance Free Batteries Sufficient For 24 Hours Nosrmal Working And Then Be Capable Of Operating The System For 60 Minutes During Emergency Condition. The Panel Shall Be Ul Listed/ Fm Approved. , Supplying, Installing, Testing And Commissioning Of Loop Card , Supplying, Installing, Testing And Commissioning Of Sounder With Strobe Light , Supplying, Installing, Testing And Commissioning Of Addressable Manual Call Point With Back Box. , Supplying, Installing, Testing And Commissioning Of 2C X 1.5 Mm², Armoured, Single Stand, Outer Sheathed, Frls, Pvc Insulated Copper Conductor Cable Confirming To Specified Is Standards . , Supply, Installation, Testing & Commissioning Of The Following: Sensors Confirming To The Description,And Standards. (All Floors& Common Area) Supplying, Installing, Testing And Commissioning Of Addressable Photo Electric Smoke Detector (Optical) With Base, Junction Box And Other Accessories (True Ceiling & Above False Ceiling) , Supplying, Installing, Testing And Commissioning Of Rate Of Rise Heat Detector With Base, Junction Box And Other Accessories. , Supplying, Installing, Testing And Commissioning Of Addressable Photo Electric Multi Sensor Detector (Optical) With Base, Junction Box And Other Accessories. , Analogue Addressable Fault Isolator Module Capable Of Monitoring Shorted Loop Circuit And Automatically Restore Communications When Shorted Conditions Are Corrected , Response Indicator For All Detectors Located Above False Ceiling For Visual Identificaion Of Detector , Supplying, Installing, Testing And Commissioning Of Analogue Addressable Monitor Module (Single Input Module) For Integrating Sprinkler Flow Switch In All Floors And Status Of Fire Pumps With Facp At Ground Floor. , Supplying, Installing, Testing And Commissioning Of Addressable Control Module For Activating The Notification Application Devices. Shall Have Supervisory Facility To Supervise The Auxillary Power Supply As Well As The Notifcation Appliance Circuits..Shall Have Binary Coding Setting Dp Switches, Shall Have An Led Indication Fornormal Working And Active Modes -Approval: Ul Listed , Supplying, Installing, Testing And Commissioning Of Power Supply Unit Which Provides 24V Dc Output For Connecting All Relay Control Modules And Other Modules. The Power Supply Unit Will Be Located In Fire Control Room At Ground Floor And In Designated Location Preferably Near To Fa/Pa Shaft In Typical Floors. , Fire Extinguishers Supplying, Installing And Commissioning Portable Fire Extinguishers Of Following Type & Capacity. (I) Carbon-Di- Oxide Type Fire Extinguisher Of 4.5 Kgs. Capacity, Co2 Gas As Per Is 15222 With Controll Discharge Mechanism Fitted With Hose & Horn Applicable On Class B Fire Rating 21Bconfirming To Is: 15683. , (Ii) Abc Powder Type Fire Extinguisher Of 4 Kgs. Capacity, With Initial Filling (Mono Ammonium Phospate Powder 90) In Brand New Cylinder With Powder Coated Finish, Stored Pressur Type, Pressure Gauge, Controllable Discharge Mechanism With Hose & Nozzle , Confirming To Is:15683. (Abc Dry Chemical Powder- Map 90%) , Signages Providing And Installing In Position The Following Tupe Of Sign Boards Made Out Of 3Mm Thick Opaque Pvc Foam Board With Computer Cut. Pvc Non-Reflective Self Adhesive Vinyle Painted Foam Board, Complete With Mirror Fasteners. Signages With Printed In Case Of Fire, Use Stairs Unless Instructed Otherwise Of 1.5Cm Height Letters In Red With White Back Ground. The Size Of The Board Shall Be 25Cm * 30Cm And Shall Be Fixed At The Height Of 2Mts, From Finished Floor Near Manual Call Points. , Providing And Fixing In Position The Signage Of Incase Of Fire Do Not Use Lift Size 8 X 8 , Providing And Fixing In Position The Signage Of Incase Of Fire Break The Glass To Be Pasted Immediately Above The Every Extinguisher.Size 6 X 6 , Providing And Fixing In Position The Signage Of Fire Extinguisher To Be Pasted Immediately Above The Every Extinguisher.Size 6 X 6 , Providing And Fixing In Position The Signage Of Fire Hydrant & Hose Reel To Be Pasted On Door Of The Every Fire Shaft At All Floors. . Size 6 X 8 , Providing And Fixing In Position The Sign Board Of Assembly Point Complete With 1 Mm Thick Rigid Plastic Board Size Of 600 Mm X 600 Mm To Be Fixed On Ground By Using A Steel Rod / Pipe At Designated. , Providing And Fixing In Position The Signage Of Fire Alarm Panel Size 6 X 6 , Providing And Fixing In Position The Signage Of Exit Signages Glow Type With Battery Backup Size 8 X 16 , Providing And Fixing In Position The Signages Fire Order It Should Contain The Following Matter On 3Mm Thick Opaque Pvc Foam Board Of Computerised Cut, Pvc Non-Reflective Self Adhesive Vinyle Painted Foam Board Of 3 * 4 , Type -I Comprising The Followinga) Alert The Security At Security Room By Actuating Manual Call Point Located At Strategic Locations.B) Evacuate The Occupants By Using Fire Exits And Emergency Exits Only And Assemble At Various Assembly Points.C) If Possible Try To Extinguish The Fire By Using Nearest / Suitable Portable Extinguisher Or Water From Nearest Wet Riser.D) Be Calm And Do Not Give Any Room From Panic, Walk, Do Not Run. E) If You Encounter Serious Difficulty In Evacution, Flat And Try To Attract Attention Of Rescue Team. , Type -Ii Comprising The Following Action By Security / Reception Upon Receipt Of Information Through Fire Alarm Or Fire Detectors Or By Using Public Address System. A) Alert The Occupants By Using Public Address System.B) Inform Fire Control Through Any One Of The Following Phone Numbers: 101, Xxxxxxxxxxxxxxxxxxxxc) Refer Evacution Plan From Evacuating Standard People.D)Guide The Fire Force, On Their Arrival To The Seat Of Fire E) In Case Of The Casualities, Call Ambulance By Dialling Number……………. , Laisoning Works: Laisoning Charges For Works Such As Filling Necessary Applications, Prepration Necessary Drawings And Submitting For Approval With Requestion Form Of Local Fire Force Department, Arranging For Inspection Of Fire Hydrant Installationsand Equipmentsbyfireforce Officers Authority Includiungnecessary Follow - Up Withconcerned Person Uptilloccupation Certifice (Oc) Is Obtained.The Scope Of Work Shall Also Include Depositing The Fees, Other Amounts As And When Required. All The Expense Incurred In Authorities Following - Up In This Regard Shall Be Borne By The Sub - Contrtactor Except For The Payments To Be Made For Only Security Deposit On Pro Rate Basis Etc., Which Will Be Reimbursed On Production Of Original Vouchers. , Lift Works: 2 Stops-Sound Proof 360° Panoramic Glass View Curved Designer Profile No Connector Holes On The Shaft Joints Cylinder Joint Cover - Matching Designer Profile Concealed Hinges With No Projected Visible Metal Cover Invisible Sensors On The Shaft Cabin Colour Matching To Lift Colour Panoramic Frameless Aluminium Door Door Handles Painted To Match Lift Colour Cabin Base Cover Plates Zero Visible Screws On Shaft / Cabin & Doors No Visible Springs On Cabin Basesafety Dual Hcc Brakes (Hardened Cross Compound) Electric Door Lock For Safety Triangle Emergency Alarm Cabin Phone With Gsm Child Safety Switch Cabin Internal Diameter= 1160Mm Height=1930Mm Clear Acess=805Mm Handle=No , Flodable Chair=No Alexa = No Capacity = 240Kg Colour = Cream White Flooring Carpet = Beigelanding Door Floor 0 =F0 Access=Side A Automatic Door Closing Right Hand Side Hinge Floor 1 - F1 Access - Side A Automatic Door Closing Right Hand Side Hinge Shaft External Diameter = 1365Mm Space Requried =1430Mm Color = Cream White Power Reuirementsingle Phase - 230V - 50/60Hz 32Amp With Circuit Breaker Stabilized Power Travel Height From F0 To F1 = 3500Mm Total Travel Height From F0 To F1 = 3500Mm Minimum Headroom Required = 2439Mm

Key Value

Document Fees
Refer document
EMD
INR 385000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail