Tender For Repair Maintenance Of Certain External Water Supply Items Of Main Water Lines From Raw Water Intake Points Pump House Float Valves Grating System Electrical Network Panels Starter Valves Filtration Beds And Other Connected Works At Arc Cha, Cuttack-Odisha

Military Engineer Services-MES has published Tender For Repair Maintenance Of Certain External Water Supply Items Of Main Water Lines From Raw Water Intake Points Pump House Float Valves Grating System Electrical Network Panels Starter Valves Filtration Beds And Other Connected Works At Arc Cha. Submission Date for this Tender is 15-03-2024. Water Supply Project Tenders in Cuttack Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

42298874
Corrigendum : Tender For Repair Maintenance Of Certain External Water Supply Items Of Main Water Lines From Raw Water Intake Points Pump House Float Valves Grating System Electrical Network Panels Starter Valves Filtration Beds And Other Connected Works At Arc Cha
Open Tender
Indian
Odisha
Cuttack
15-03-2024

Tender Details

Repair Maintenance Of Certain External Water Supply Items Of Main Water Lines From Raw Water Intake Points Pump House Float Valves Grating System Electrical Network Panels Starter Valves Filtration Beds And Other Connected Works At Arc Charbatia Rx A Repair Maintenance Of Certain External Water Supply

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 44160.0 /-
Tender Value
INR 22.08 Lakhs /-

BOQ Items

Name of Work: REPAIR/MAINTENANCE OF CERTAIN EXTERNAL WATER SUPPLY ITEMS OF MAIN WATER LINES FROM RAW WATER INTAKE POINTS, PUMP HOUSE, FLOAT VALVES, GRATING SYSTEM, ELECTRICAL NETWORK/PANELS/STARTER, VALVES FILTRATION BEDS AND OTHER CONNECTED WORKS AT ARC CHARBATIA RX AREA UNDER GE (I) (CG) BHUBANESWAR
Sl. No. Item Description
1Dismantling wrought iron or mild steel framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars,grill mesh arrnagement ; barred iron doors, ladders, framed balusters, walk ways,ailings, framework of water tanks,including chequred plate & MS anglecomplete all as specified and directed.
2M&L for Mild steel Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars,grill mesh arrnagement ; barred iron doors, ladders, framed balusters, walk ways,ailings, framework of water tanks and similar work complete including necessary welding,fastening as required conforming to Fe.290.Gde-E-165, complete all as specified and directed. Note :- (i) The scope includes fixing of the item on surface or underwater at river banks as directed. (ii) PCC work will be measured and paid seperately
3M&L for removing of wild grass/vegetation/solid/earth particles/tree logs or other foreign particles which disturbed the suction of raw water from theof course of river (MahanadiRiver) into the intake channelof the suction side of the raw water pumps installed at Chasapada Pump House so that the intake channel get sufficient raw water for pumping to the sedimentation bed by using sufficient & skilled labour from the suction pipe foot valve laying at the depth of aboutapprox 10 feet under the water complete all as specified and directed. Note: (i) T&P required for removal/excavation/clearing shall be provided by the contractor and rate for the same be included in the quoted rates. (ii) SkilledManpower required for making area at footvalve clear for intake shall be provided by the contractor and contractor shall provide all safety equipments for manpower for doing the necessary jobs in river/bank area and contractor will be responsible for the safe execution of the said job. (iii) The contractor should detailed the manpower within 1 hr after intimation by department through any medium. (iv) If the contractor failed to detailed the manpower than Rs 1000 per day will be charged as penalty in case of non-compliance or non-rectification of job and being essential nature of work necessary action will be initiated.
4Dismantling and taking out existing repairable foot valve of size 250 mm bore from the pipeline andcarrying out minor repairs/servicing/cleaning/grinding and refixing the same with necessary accessories for fittings complete with necessary nuts,bolts and gasket accessories as per site requirement complete all as specified and directed.
5Dismantling and taking out existing repairable foot valve of size 200 mm bore from the pipeline andcarrying out minor repairs/servicing/cleaning/grinding and refixing the same with necessary accessories for fittings complete with necessary nuts,bolts and gasket accessories as per site requirement complete all as specified and directed.
6Servicing of sluice valves cast iron body by greasing/oilingusing T&P as required asper manufacturer’s instructions & providing gland rope of superior quality to stop any leakage of sluice valves of size 100 mm to 150 mm diameter including replacement of defective brass check nuts complete all as specified and directed.
7All as per item No. 6 above but 200 to 300 mm borecomplete all as specified and directed.
8All as per item No. 6 above but 450 mm bore complete all as specified and directed.
9S&F Sluice valve 250mm dia, cast iron body,PN-1.6, with flanged ends drilled at both ends, conforming to IS-14846, ISI marked, having brass spindle with iron wheel at top, with nuts, bolts , washers, rubber gasket etc, including taking down old unserviceable sluice valve complete all as specified and directed.
10S&F Sluice valve 200mm dia, cast iron body,PN-1.6, with flanged ends drilled at both ends, conforming to IS-14846, ISI marked, having brass spindle with iron wheel at top, with nuts, bolts , washers, rubber gasket etc, including taking down old unserviceable sluice valve complete all as specified and directed.
11S&F Sluice valve 150mm dia, cast iron body,PN-1.6, with flanged ends drilled at both ends, conforming to IS-14846, ISI marked, having brass spindle with iron wheel at top, with nuts, bolts , washers, rubber gasket etc, including taking down old unserviceable sluice valve complete all as specified and directed.
12S&F Sluice valve 100mm dia, cast iron body,PN-1.6, with flanged ends drilled at both ends, conforming to IS-14846, ISI marked, having brass spindle with iron wheel at top, with nuts, bolts , washers, rubber gasket etc, including taking down old unserviceable sluice valve complete all as specified and directed.
13S&Fcast iron non-return (reflux)valve of 250 mm bore, , flange type with by-pass arrangement suitable for 250 mm dia water mains conforming to IS-5312 Part-I class PN 1.6 including taking down old unserviceable non return valve complete all as specified and directed.
14S&Fcast iron non-return (reflux)valve of 200 mm bore, flange type with by-pass arrangement suitable for 200 mm dia water mains conforming to IS-5312 Part-I class PN 1.6 including taking down old unserviceable non return valve complete all as specified and directed.
15S&F 250mm bore, cast iron butter fly valve both end flanged, class PN 1.6 conforming to relevant IS 13095(1991) lever operated including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking down old unserviceable butterfly valve complete all as specified and directed.
16S&F 200mm bore, cast iron butterfly valve both end flanged, class PN 1.6 conforming to relevant IS 13095(1991) lever operated including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking down old unserviceable butterfly valve complete all as specified and directed.
17S&F 150mm bore, cast iron butterfly valve both end flanged, class PN 1.6 conforming to relevant IS 13095(1991) lever operated including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking down old unserviceable butterfly valve complete all as specified and directed.
18S&F 100mm bore, cast iron butterfly valve both end flanged, class PN 1.6 conforming to relevant IS 13095(1991) lever operated including necessary jointing materials like nuts, bolt, washer and rubber/fiber board gasket including taking down old unserviceable butterfly valve complete all as specified and directed.
19M&L for repacking stuffing box of sluice valve 250mm spindle including taking apart and reassembling complete all as specified and directed.
20M&L for repacking stuffing box of sluice valve 200mm spindle including taking apart and reassembling complete all as specified and directed.
21M&L for taking out sluice valves 250 mmrefacing, regrinding and refixing complete all as specified and directed.
22M&L for taking out sluice valves 200 mmrefacing, regrinding and refixing complete all as specified and directed.
23Supplying and laying submersible flat cable PVC insulated and PVC sheathed LT 1100 volt grade with copper conductor of size16 sqmm3 core including taking down old unserviceable cable complete all as specified and directed.
24Supplying and laying submersible flat cable PVC insulated and PVC sheathed LT 1100 volt grade with copper conductor of size10 sqmm3 core including taking down old unserviceable cable complete all as specified and directed.
25Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq mm 3 core including taking down old unserviceable cable complete all as specified and directed.
26Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq mm 3 core including taking down old unserviceable cable complete all as specified and directed.
27Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 sq mm 3.5 core complete all as specified and directed.
28Material and labour for fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 sq mm 3.5 core including taking down old unserviceable cable complete all as specified and directed.
29S & F MS chequered plate of 7 mm thickness made of Fe-410-W (Gde-E-250) quality A cutting into required shape/sizefixed with nuts bolts and washers etc including taking down old UNSV MS chequered plate of any size complete all as specified and directed.
30S & F MS angle iron of grade Fe-410-W (Gde-E-250) quality A and cutting into required shape/size complete all as specified and directed.
31S&F Cast Iron Air release valves with double air Outlets, conforming to IS 14845 of size 80 mm dia bore and fixing up in Cast Iron Water supply mains of size 450/300/250/200 mm dia , PN 1.6 flanged type/screwed type as per site requirment complete including taking down old unserviceable ARV complete all as specified and directed.
32Dewatering of Raw water from filter bed at Long term water supply including mud by pumping or bailingout muddy water from filtration bed which can not be drained out by operation of valves, complete all as specified and directed.
33M&L for Brick massonary valve pit with 230 mm thick brick wall chamber of size internally (1500 x 1500 x 900mm) with plastering in CM 1:6 10mm thick internally and externally 15mm thick, 150mm below the G.L. with 1:6 CM, PCC 1:4:8 type D2 by using 40mm gradded aggregate foundation of size 1900x1900mm of 100mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 50X50X6mm thick angle iron frame and 3.15mm thick MS Sheet as cover with two Nos of 150mm length hinges and one No handle made out of MS round bar 10mm dia with necessary locking arrangementincluding painting to the steel surfaces with two coats of synthetic enamel paint over a coat of redoxide primer, including demolition of existing valve pit,complete all as specified and directed. Note :- The item includesgeneral cleaning of vegetation/plant around chamber.
34M&L for Brick massonary valve pit with 230 mm thick brick wall chamber of size internally (1200 x 1200 x 900mm) with plastering in CM 1:6 10mm thick internally and externally 15mm thick, 150mm below the G.L. with 1:6 CM, PCC 1:4:8 type D2 by using 40mm gradded aggregate foundation of size 1450x1450mm of 100mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 50X50X6mm thick angle iron frame and 3.15mm thick MS Sheet as cover with two Nos of 150mm length hinges and one No handle made out of MS round bar 10mm dia with necessary locking arrangementincluding painting to the steel surfaces with two coats of synthetic enamel paint over a coat of redoxide primer, including demolition of existing valve pit,complete all as specified and directed. Note :- The item includesgeneral cleaning of vegetation/plant around chamber.
35M&L for Brick massonary valve pit with 230 mm thick brick wall chamber of size internally (750 x 750 x 900mm) with plastering in CM 1:6 10mm thick internally and externally 15mm thick, 150mm below the G.L. with 1:6 CM, PCC 1:4:8 type D2 by using 40mm gradded aggregate foundation of size 1150x1150mm of 100mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 50X50X6mm thick angle iron frame and 3.15mm thick MS Sheet as cover with two Nos of 150mm length hinges and one No handle made out of MS round bar 10mm dia with necessary locking arrangementincluding painting to the steel surfaces with two coats of synthetic enamel paint over a coat of redoxide primer, including demolition of existing valve pit, complete all as specified and directed. Note :- The item includesgeneral cleaning of vegetation/plant around chamber.
36Collecting water samples from deferent places like water pump for Testing of water at PHED laboratory for bacteriological test and chemical qualityof water and test result submit to Engineer-in-Charge complete all as specified and directed.
37M&L for refacing, regrinding and refixing of sluice valve, complete all as specified and directed of following sizes :-
38(a) 80 mm dia
39(b) 100 mm dia
40(c)150 mm dia
41(d) 300 mm dia
42Supply and fix in replacement of notice board of overall size shall be 1200mm long, 75mm deep and 600mm high, 25mmx75mm particle board frame of commercial face with 6mm thick MDF edging alround shall be provided, 19mm thick soft wood board shall be fixed in side the frame over which best quality green baize cloth shall be fixed, Aluminum flat of 63mmx 3.25mm shall be provided alround at the back of the board, on front side 22mmx10mm aluminum channel shall be provided in side of particle board frame to house 4mm thick glass shutter (sliding type with necessary fittings) complete all as specified and directed.
43M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, connected to galvanized iron strip 32mm x 6mm by means of bots, nuts and washer of galvanized iron or steel all as shown in electrical plate No. 3 SSR Part I connected to earthing test point with 40mm dia light grade protection pipe up to 7.5m long including earthwork and excavation , charcoal-dust, salt,PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for earth chamber provn of RCC cover 40 mm thick in 1:2:4 mix type B1 funnel, complete all as specified and directed.
44S&Fin replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed.
45M&L for preparation of old painted surface and painting with spray gun at pump house, pipe lines, sluice valves, pumps and motors as per colour code with two coats of synthetic enamel paint over a coat of primer for equipments complete all as specified and directed. Equipment details: (a) Centrifugal Pumpsets - 04 Nos (b) Sulice/ butterfly valves - 4 Nos (c) NRV - 04 Nos (d) MS/CI pipe line of any dia inside pump house bldg
46Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundationand getting out in soft/loose soil concrete complete all as specified and directed.
47Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
48Removing excavated spoil to a distancen.exc. 50 m and depositing where directed at a level n.exc 1.5m above the starting pointcomplete all as specified and directed.
49M&L for sand cushion for under ground cable protection and consolidated and compacted with clean dry river sand complete all as specified and directed. Note- Punned thickness will be measured at the time of measurement and payment.
50S&F bricks fly ash bricks locally available of size 230mm x 115mm x 75mm best quality laid in trenches over sand cushioning for cable protection complete all as specified and directed.
51Supply only grease suitable for water supply installation complete all as specified and directed.
52Supply only cotton waste for water supply installation complete all as specified and directed.
53Demolition of brickwork or stone/boulder masonary, built in cement mortar or cement lime mortor including all quions, aches,pillars etc but excluding ashlar facing dressed stonewrok and precast concrete articlesand deposted at site for re-use complete all as specified and directed.
54M& L for brickwork masonary in cement mortar (CM1:4) with old size brick obtained from demolition (Except bricks) straight or curved on plan exc 6 m mean radius complete all as specified and directed.
55Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for and including removing of demolished material from site complete all as specified and directed.
56Material and labour for mass concrete nominal mix PCC 1:4:8type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling / mass concretecomplete all as specified and directed.
57M&Lfor flyash brickwork with subclass "B" bricks,staight or curved on plan exc 6 m mean radius built in CM1:4 complete all as specified and directed.
58M & L for cement concrete 1:3:6 type C-1(20 mm graded aggregate) as in coping including necessary form work complete all as specified and directed.
59M & L for rendering in cement plaster (CM 1:6:)15 mmthick onfair faces of brick work/concrete surface complete all as specified and directed.
60Material and labour for mass concrete mix PCC 1:3:6type C2 (using 40 mm graded crushed stone aggregate) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
61Supply & Fixfire bucket stand along with 4 nos Bucket canopy type to be installed at pumphoses complete all as specified and directed.
62Supply & Fixfire extinguisher CO2type,6.5 KG trolley mounted conforms to IS16018 to be installed at pumphoses complete all as specified and directed.
63Supply & Fix in replacement old unserviceable 250mm footvalve from chasapada pumphouse/clearwater pumphousecomplete all as specified and directed. Note :- rate for T & Pdeemed to be included in the quoted rateby the contractor.
64Supply & Fix in replacement old unserviceable 200mm footvalve from chasapada pumphouse/clearwater pumphousecomplete all as specified and directed. Note :- rate for T & Pdeemed to be included in the quoted rateby the contractor.
65Material & Labour for Shifting of existing serviceable Foot valve of 300mm/250mm/ 200mm bore from the pipeline & fixing the same in existing intake water line with necessaryGasket, Nuts & bolts at chasapada pumphouse as per site requirmentfrom mahanadi river including necessary tools & plants complete all as specified and directed.
66Material & labour for lifting & lowering of unserviceablesubmersible pump 1 HP from well for repair to submersible pump including winding & minor repairs to pumps including gasket & seals complete all as specified and directed.
67S&F in replacement400 W LED flood light/highmast light fitting energy efficient light distributionincluding all necessary components/control unit,clamps, nuts , bolts or fixing arrangement complete all as specified and directed. (Note: Necessary manpower/accessories ladder/ tapping/connecting wire etc required for replacement is deemed to be included in quoted rate).
68Labour only for site clearance/surface cleaning by removing of hurbs/shurbs/wild vegetation/removing surpus soil to a distance n exc 50 mtr and making good surface of the E/M installations area & water supplynetwork area with suitable T&P complete all as specified and directed. Note:- All T&P will be provided by the contractor without any extra cost and also not to cut any tree/plants during the execution of works.
69Supply only gland packing 12mm/14mm suitable for pumpset 60HP/80HP/100HP/ 125HPcomplete all as specified and directed.