Tender For Repair To Summer Appliances And Certain Em Works Under Ge ( West ) Ferozepur Cantt

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
INR 25 Lakhs /-

BOQ Items

Name of Work: Repair to Summer appliances and certain E/M works under AGE (E/M) of GE (W) Ferozpur cantt.
Sl. No. Item Description
1WATER COOLER STORAGE TYPE Taking out existing compressor unit from the water cooler of capacity 40/80/120/150 litre of any make including removed of all other unserviceableparts/spares such as strainers, filter, capillary tubes suction /discharge pipe, thermostat switch, float valve, push cock running , startingcapacitor, over load relay complete all as specified and directed.
2S&F company repaired compressor in lieu of defective compressor to water cooler of 150 litre/hour cooling capacity including Painting, jointing capillary tube and testing the compressor complete all as specified and directed.
3All as per Srl No. 2 here-in-before but of cooling capacity 60 litre/hour.
4All as per srl no. 2 here-in-before but of cooling capacity 40 litre/hour.
5S&F new compressor to water cooler of 150 litre/hour cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Copeland/Bluestar/Godrej/GMCC
6S&F new compressor to water cooler of60 litre/hour cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Copeland/Bluestar/Godrej/GMCC
7S&F new compressor to water cooler of 40 litre/hour cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Copeland/Bluestar/Godrej/GMCC
8M&L servicing of water cooler any size and make including drain outwater cleaning of water tank and cleaning of condersor coil withanti scaling solution complete all as specified and directed.
9M&L charging of water cooler with R-134a,R-22,R-290,R-410 gas complete includingleakage test and testingof water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as specified and directed.
10M&L repairing the water cooler / body by replacing rusted MS sheet body with new MS sheet of 16 SWG approx area 2.5 Square feet complete including replacement of unserviceable channel legs, fan motar base complete all as specified and directed.
11Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling the motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire after providing "E" class insulation material complete including replacement of unserviceable pad MS clamps, nut and bolt, varnishing & refixing the motor in the watercooler and testing of water cooler complete all as specified and directed.
12Supply, fixing and connecting in replacement new fan motor of water cooler capacity 1/8 HP 230 Volts 50 c/scomplete all as specified and directed. Makes: MIE/Khaitan/ Crompton Greaves
13S&F in replacement of fan blades of fan motor of water cooler of make sidwal of capacity 150 litre made out of GI sheet complete all as per existing shape and size complete all as specified and directed.
14Supply, fixing and connecting the Running capacitor 36 MFD of water cooler of capacity 120/150 litre complete all as specified as directed. Makes : USHA/UNISTAR/TIBCON/Havells/Hightech or equivalent.
15All as per srl item 14 here-in-before but Starting capacitor 80-100 MFD.
16All as per srl item 14 here-in-before butOver load protector as per sample.
17All as per srl item 14 here-in-before but Starting relay 1/8 HP as per sample.
18All as per srl item 14 here-in-before but Thermostat switch for water cooler as per sample.
19All as per srl item 14 here-in-before Push cock brass HD chromium plated.
20All as per srl item 14 here-in-before but float valve ½” dia, brass with ball.
21All as per srl item 14 here-in-before but Rubber hose pipe/ for 1 ½” dia and 1.5 m longdrain pipe.
22All as per srl item 14 here-in-before but Over load/relay complete box type Y-412.
23REFRIGIRATOR 310 litre Taking outexisting compressor unit from the refrigerator of any capacity, of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed.
24Taking outexisting compressor unit from the deep freezerof any capacity of any make including removed of all otherunserviceableparts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder,capillary tubes, freezer door complete all asspecified and directed.
25S&F only company repaired compressor in lieu of defective compressor to refrigerator of 180/165 litre capacity including jointing capillary and testing the compressor complete all as specified and directed.
26S&F only company repaired compressor in lieu of defective compressor to refrigerator of 310/280 litre capacity including jointing capillary and testing the compressor complete all as specified and directed.
27S&F company repaired compressor in lieu of defective compressor to deep freezer of 200/250 litre capacity including jointing capillary and testing the compressor complete all as specified and directed.
28S&F company repaired compressor in lieu of defective compressor to deep freezer of 300/400 litre capacity including jointing capillary and testing the compressor complete all as specified and directed.
29S&F new compressor to refrigerator ofcapacity 310 litreincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /videocon//Godrej/Whirlpool/LG
30S&F new compressor to refrigerator ofcapacity 195/165 litreincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Makes :Tecumseh /videocon//Godrej/Whirlpool/LG
31S&F new compressor to Deep freezer of capacity 320 litreincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Hittchi/Bluestar/Godrej/LG/Copland
32S&F new compressor to Deep freezer of capacity 250 litreincluding, jointing capillary tube and testing the compressor complete all as specified and directed. Makes : Tecumseh /Hittchi/Bluestar/Godrej/LG/Copland
33Charging of gas in Refrigerator/Deep Freezerwith R-134a,,R-290,R-410 & R-600 gas complete includingleakage test and testingof water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as directed
34Supply, fixing and connecting Plunger type relay 1/6 HP of REFRIGERATOR complete all as specified and directed.
35All as per ser item No. 34 here-in-before butOver load protector 1/6 HP.
36All as per ser item No. 34 here-in-before butThermostat switch with knob - u-50-1018.
37All as per ser item No. 34 here-in-before butGlass cover heavy duty of Refrigeratorcapacity 310 litre.
38All as per ser item No. 34 here-in-before butRepair to Freezer door forRefrigerator of Cap 310 litre.
39All as per ser item No. 34 here-in-before butTimer controller for Double doorRefrigerator of Cap 310 litre.
40All as per ser item No. 34 here-in-before butHeating Elemnet for Double doorRefrigerator of Cap 310 litre.
41All as per ser item No. 34 here-in-before butBioMetal for Double doorRefrigerator of Cap 310 litre.
42All as per ser item No. 34 here-in-before butSensor for Double doorRefrigerator of Cap 310 litre.
43S&F PCB unit of Double Door Refrigertor 310/400 litres of existing make complete all as specified and directed.
44S&FButter box / any try any type and size as per sample complete suitable for whirlpool/Samsungrefrigarater of Cap 310 litre.
45Supply, fixing and connecting the Running capacitor 06-15 MFD of Refrigerator/ Deep Freezer of capacity 120/150 litre complete all as specified and directed. Makes : USHA/UNISTAR/TIBCON/Havells/Hightech
46Supply, fixing and connecting, Replacement ofthe existing damage, choked Backside Condensor Coil from the Refrigerator of Cap 165/195litre of any Make complete all as specified and directed.
47Supply, fixing and connecting, Replacement ofthe existing damage, choked evaporator (Freezer) from the Refrigerator of Cap 310 litre of any Make complete all as specified and directed.
48All as per ser item No. 47 here-in-before but Replacement ofthe existing damage choked evaporator (Freezer)from the Refrigerator of Cap 165 litre of any Make.
49Repairing the Refrigerator /Deep Freezer body by replacing rusted MS sheet base with new MS sheet of 16 SWG approx area 2.5 Sq ft complete including replacement of unserviceable channel legs, fan motar base complete all as specified and directed.
50Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire after providing "E" class insulator material including replacement of bushes, name pad and varnishing refixing the motor in the DF Ref and testing of Desert Cooler complete all as specified and directed.
51Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and connecting new fan motor & Fan Blade complete all as specified and directed.
52AIR CONDITIONER WINDOW TYPE 1.5 TON CAP Taking out existing serviceable window typeAir conditioner of capacity 1.5 Ton of any make and capacity and refixing the same to its position after serviceing with anti scaling solution and cleaning complete including removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload Running capacitor relay etc and replaced with new parts as required complete all as specified and directed.
53All as per ser item No. 52 here-in-before but split type Air Conditioner of capacity 1.5 Ton.
54S&F company repaired compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor, capillary, copper tubing as required and testing the compressor complete all as specified and directed..
55S&F new compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor,capillary,copper tubing as required and testing the compressor complete all as specified anddirected. Makes : Tecumseh /Bluestar/Godrej/Hittchi/Whirlpool
56S&F new compressor in lieu of defective compressor to Air Conditioner of 2.0 Ton capacity including jointing compressor,capillary, copper tubing as required and testing the compressor complete all as specified and directed. Makes : Tecumseh /Bluestar/Godrej/Hittchi/Whirlpool
57S&F in replacement of copper tubing for split type Air conditioner of 1/4 ", 1/2" or any size required at site including insulation pipe complete all as specified and directed.
58M&L charging of gas in Split/Window AC with R-134a, R-22,R-32 & R-410 gas complete includingleakage test and testing of water cooler on full load for 24 hours continuously at site of any Make of any capacity complete all as directed.
59Dismantling taking out existing unserviceable fan motor of capacity 1/8 HP from window type Air conditioner/Split type dismantling the motor and taking out old burnt copper winding wire and rewinding of fan motor with similarsize super enamelled copper winding wire after providing"E" class insulation material complete includingreplacement of unserviceable rubber pad MS clamp nut bolt varnishing and refixing themotor in the A/C and testing of Air conditioner complete all as specified and directed.
60S&F outer unit of spilt type AC 1.5 Tonn of existing make complete with condenser coil and compressor etc complete all as specified and directed.
61S&F inner unit of spilt type AC 1.5 Tonn of existing make complete all as specified and directed.
62S&F PCB unit of spilt type AC of existing make complete all as specified and directed.
63M&L repair of existing unserviceable PCB unit of spilt type AC of existing make complete all as specified and directed.
64M&L repair of existing unserviceable PCB unit of invertor type spilt AC of existing make complete all as specified and directed.
65S&F in replacement of condenser/Evaporator coil of window type AC of 1.5 TR capacity of any make complete all as specified and directed.
66S&F in replacement of condenser/Evaporator coil of split type AC of 1.5 TR capacity of any make complete all as specified and directed.
67Supply, fixing and connecting running capacitor 36-50 MFD complete all as specified and directed.
68All as per ser item No. 67 here-in-before but Over Load protector No SR-1622 complete all as specified and directed.
69All as per ser item No. 67 here-in-before but Starting capacitor 80-100 MFD.
70All as per ser item No. 67 here-in-before but Starting Relay box type 1/8 HP SR-1622 complete all as specified and directed.
71Supply, fixing and connecting new fan motor 1/8 HP 230 Volts 50 C/s single phase complete including MS clamps and rubber pad, Fan Blade including taking out existing unserviceable fan motor from the Air conditioner complete all as specified and directed.
72M&L shifting of airconditioner split type of any make from its original position to another position with andincluding any B&R work reqd and electric work requiredfor it complete all as specified and directed.
73M&L shifting of air conditioner window type of anymake from its original position to another position with andincluding any B&R work and electric work requiredfor it complete all as specified and directed.
74DESERT COOLER Taking out exiting unserviceable fan motor of capacity 1/8 HP from the desert cooler/ dismantling the motor and taking out old burnt Aluminium winding and rewinding of blower motor with similar size of super enamelled Aluminium winding wire after providing "E" class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the Desert Cooler and testing of Desert Cooler complete all as specified and directed.
75Taking out existing unserviceable Tulu pump (water pump) from the desert cooler S&F connecting new Tulu pump 1/20 HP 230 Volt 50 C/S single phase of ISI Marked complete all as specified and directed.
76Taking out existing unserviceable fan motor from the desert cooler supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber pad complete all as specified and directed.
77Replacement of Desert Cooler front show grill made of PGI sheet 20 gauge duly painted all as specified and directed.
78Replacement of Desert Cooler sides Shutters (Set of 3) made of PGI sheet 20 gauge with pad sporting frame of size duly painted complete all as specified and directed.
79Replacement of capacitor 4 MFD, 230 Volts 50 c/s of complete all as specified and directed.
80Replacement of 3 wayPVC distributer complete all as specified and directed.
81Replacement of selector switch with knob complete all as specified and directed.
82Taking out unserviceable fan bladesand S&F new blade of fan motor from the desert cooler standard quality as per existing size including taking down old unserviceable fan blade complete all as specified and directed.
83Taking out existing serviceable fan motor and Tulu pump from the unserviceable body of desert cooler carefully supply of desert cooler body made out of GI sheet 18 gauge duly painted complete including shutters front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and Tulu pump and testing complete all as specified and directed.
84M&L painting of desert cooler body at site of any make and capacity with one coat of approved quality synthetic enamelled paint over a coat of red oxide primer after cleaning of dust rust and preparation of surface both inside and out side complete all as specified and directed.
85S&F PVC pipe 15mm diain each cooler complete all as specified and directed.
86Taking out unserviceable supporting leg fan motor with screw and fixing new supporting legs as per existing size complete all as specified and directed.
87Replacement of wood wool pad, supporting wire frame (set of three) and fixing in water cooler all as specified and directed.
88REPAIR TO VOLTAGE STABILIZER OF CAPACITY5 KVA MAKE - INTEG/NAYAR/ BLUE LINE COMPRISING THE FOLOWING: Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire after provisioning "E" class insulator material varnishing and refixing complete all as specified and directed.
89S&F of new printed circuit board complex with condenser choke pre fixer and time delay relay including taking down old unserviceable printed circuit board complete all as specified and directed.
90S&F Volt meter Display 0-300 Volts single phase 230 Volts complete all as specified and directed. Make: Bajaj/Crompton/GEC
91S&F Bakelite connector in main connection lead complete all as specified and directed.
92REPAIR TO VOLTAGE STABILIZER OF CAPACITY 4 KVA OF MAKE - INTEG/ NAYAR/ ELECTRON COMPRISING OF FOLLOWING:- Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire after provisioning"E" class insulator material varnishing and refixing complete all as specified and directed.
93S&F of new printed circuit board complete with condenser dioel pre fixer and time delay relay including taking down old unserviceable printed circuit board complete all as specified and directed.
94S&F Bakelite connector in main connection lead complete all as specified and directed.
95S&F Volt meter Display 0-300 Volts single phase 230 Volts complete all as specified and directed. Makes : Bajaj/Crompton/GEC
96REPAIR TO VOLTAGE STABILIZER OF CAPACITY 3 KVA MAKE- ELECTRON COMPRISING THE FOLLOWING :- Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire after provisioning "E" class insulator material varnishing and refixing complete all as specified and directed.
97S&F Volt meter Display 0-300 Volts single phase 230 Volts complete all as specified and directed. Make: Bajaj/Crompton/GEC
98S&F Voltage stabilizer with 100% copper winding for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 5.0 KVA . Make: Microtek/Voltas or equivalent
99Taking out carefully existing unserviceable copper PVCflexible 3 core cable and S&F PVC sheathed copper cable 3 core of size 40/ 00.0076 complete all as specified and directed.
100Taking out carefully existing unserviceable copper PVCflexible 3 core cable and S&F PVC sheathed copper cable 3 core of size 70/ 00.0076 complete all as specified and directed.
101M&L replacement of unserviceable existing reverse valve copper tubing as required on site for AC all as specified and directed.
102Servicing and repairing of Aqua Guard water purifier of any cap with replacement of following parts of Make :- Aqua guard, Kent : (a) Primary filter Small
103(b) Primary filter Long
104(c) Carbon In Line Candle
105(d) Inline Sediment Candle
106(f) Long CTO Candle
107(h) Booster Pump 100 gpd
108(h) Booster Pump Head
109(j) SMPS Power Supply
110(k) Solenoidal ValveCopper
111(l) 100 GPD membrane
112(o)PVC pipe gripper at Primary filter ( set of two)
113(p) Replacement of Float Valve switch
114(q) PVCpipe of 1/4" as per exiting size
115(r) Primary filter case with clamps
116(s) Membrane Hosing A per Existing size