Tender For Repair And Maintenance Of Amf Panel At Domestic Area At Af Stn Jodhpur, jodhpur-Rajasthan

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Amf Panel At Domestic Area At Af Stn Jodhpur. Submission Date for this Tender is 13-03-2024. Electrical Panel Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

42296267
Corrigendum : Tender For Repair And Maintenance Of Amf Panel At Domestic Area At Af Stn Jodhpur
Open Tender
Indian
Rajasthan
jodhpur
13-03-2024

Tender Details

Repair And Maintenance Of Amf Panel At Domestic Area At Af Stn Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Mar-2024 amendment Other 06-03-2024
2 06-Mar-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-03-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 29500.0 /-
Tender Value
INR 14.70 Lakhs /-

BOQ Items

Name of Work:Commander Works Engineers, Air Force, Jodhpur
Sl. No. Item Description
1Taking down old unserviceable LT UG Cable from trenches/on poles/ Floor/roof of any size
2Taking down old unserviceable AMF panel of any size
3Supply, laying and testing cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured , electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor of size 3.5 core 120 sq mm
4Supply, laying and testing cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured , electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor of size 3.5 core 95 sq mm
5Supply, laying and testing cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured , electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor of size 3.5 core 50 sq mm
6Supply, installation, testing and commissioning of AMF Panel outdoor type, 125 KVA DG Set with alluminium busbar of capacity 400 Amps, TPN powder coated (coloured )heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 250 Amps consisting the following:-(INST LAB ,BASE OPS)INCOMING from 125 KVA (i)MCCB 250 Amp thermal megnetic release type FP 25 KA- 01 No(ii)Spreaders for 400 AmpsFP - 01 Set (iii)Extended Rotary handle 250Amps FP- 01 No (iv) Power Contactor 200 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC- 01 No (vi)C.T. 200/5A CL-1.0 10 VA - 03 Nos (vii)Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix)Control MCB 6A SP 10 KA C curve - 03 Nos (x) VMR - 01 No(xi) In built on load change over switch 250A for bypassing of AMF panel - 01 NoOutgoing (i) MCCB 250 Ampthermal megnetic release typeFP 25 KA - 01 No (ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay - 06 Nos (iv) SMPS 12V, DC, 10A- 01 No (v) Emergency stop P.B - 01 No(vi) Digital Amp meter 24V, DC - 01 No(vii) DigitalVolt meter 24V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve - 03 Nos(ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No (xi)Extended Rotary handle 250Amps FP- 01 No
7Supply, installation, testing and commissioning of AMF Panel outdoor type, 100 kva DG Set with alluminium busbar of capacity 300 Amps, TPN powder coated (coloured )heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 250 Amps consisting the following:-( 32 SQN,10SQN) INCOMING from 100 KVA (i)MCCB 200 Amp thermal megnetic release type FP 25 KA- 01 No (ii)Spreaders for 400 AmpsFP - 01 Set (iii)Extended Rotary handle 200Amps FP- 01 No (iv) Power Contactor 200 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC- 01 No (vi)C.T. 200/5A CL-1.0 10 VA - 03 Nos (vii)Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix)Control MCB 6A SP 10 KA C curve - 03 Nos (x) VMR - 01 No (xi) In built on load change over switch 250A for bypassing of AMF panel - 01 NoOutgoing (i) MCCB 200 Ampthermal megnetic release typeFP 25 KA - 01 No(ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay - 06 Nos (iv) SMPS 12V, DC, 10A- 01 No (v) Emergency stop P.B - 01 No (vi) Digital Amp meter 24V, DC - 01 No (vii) DigitalVolt meter 24V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve - 03 Nos (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No(xi)Extended Rotary handle 200Amps FP- 01 No
8Supply, installation, testing and commissioning in repair of AMF Panel outdoor type, 20 kva DG Set with alluminium busbar of capacity 125 Amps, TPN powder coated (coloured )heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 100 Amps consisting the following:-(SALAWAS ATC NO 01 AND NO 02)INCOMING from 20 KVA (i)MCCB 40 Amp thermal megnetic release type FP 10 KA- 01 No (ii)Spreaders for 100 AmpsFP - 01 Set (iii)Extended Rotary handle 40Amps FP- 01 No (iv) Power Contactor 63 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC- 01 No (vi)C.T. 100/5A CL-1.0 10 VA - 03 Nos (vii)Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix)Control MCB 6A SP 10 KA C curve - 03 Nos (x) VMR - 01 No(xi) In built on load change over switch 100A for bypassing of AMF panel - 01 NoOutgoing (i) MCCB 40 Ampthermal megnetic release typeFP 10 KA - 01 No(ii) Power Contactor 63 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay - 06 Nos(iv) SMPS 12V, DC, 10A- 01 No (v) Emergency stop P.B - 01 No(vi) Digital Amp meter 24V, DC - 01 No(vii) DigitalVolt meter 24V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve - 03 Nos(ix) Hooter - 01 No(x) PROCOM UNIT (DGC6D) FOR control - 01 No (xi)Extended Rotary handle 400Amps FP- 01 No
9Supply, installation, testing and commissioning of AMF Panel outdoor type, 75 kva DG Set with alluminium busbar of capacity 250 Amps, TPN powder coated (coloured )heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 150 Amps consisting the following:-( DWR )INCOMING from 75 KVA (i)MCCB 150 Amp thermal megnetic release type FP 16 KA- 01 No (ii)Spreaders for 250 AmpsFP - 01 Set (iii)Extended Rotary handle 250Amps FP- 01 No (iv) Power Contactor 150 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC- 01 No (vi)C.T. 200/5A CL-1.0 10 VA - 03 Nos (vii)Digital MF meter 96 x 96 mm with 485 Port CL 1.0 - 01 No (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix)Control MCB 6A SP 10 KA C curve - 03 Nos (x) VMR - 01 No (xi) In built on load change over switch 200A for bypassing of AMF panel - 01 NoOutgoing (i) MCCB 150 Ampthermal megnetic release typeFP 16 KA - 01 No(ii) Power Contactor 150 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF relay - 06 Nos (iv) SMPS 12V, DC, 10A- 01 No (v) Emergency stop P.B - 01 No (vi) Digital Amp meter 24V, DC - 01 No (vii) DigitalVolt meter 24V, DC - 01 No (viii) Control MCB 6A SP 10 KA C Curve - 03 Nos (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No (xi)Extended Rotary handle 250Amps FP- 01 No
10Material & labour in repair for earthing complete with galvanised steel earth electrode 60cm x 60cm x 6 mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than1.5m below ground level connected to and including GI strip earth lead25*4 mm dia by meansof nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil, PCC (1:3:6) Type C1 in earth pit chamber, precast RCC cover50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GIprotection pipe, test point etc. complete all as specified and directed. Note:-The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
11Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil.
12Returning filling in including spreading leveling watering and well ramming inlayers not exceeding 25 cm in soft / hard dense soil.
13Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils.
14Sand cusioning of tibba sand for XLPEcable with screened & washed sand & punning to providea required cover.
15Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm as directed