Public Administrative Department Local Bodies Closing in 0 days TDR #42294513

Tender For Construction Of Hsc At Raykera Block Bharno District Gumla

Issued by Local Bodies · bharno, Jharkhand
Tender Value
55.50 Lakhs
Estimated cost
Bid Submission
22 Feb 2024
0 days left
EMD
1.11 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bharno → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Hsc At Raykera Block Bharno District Gumla

BOQ

Name of Work: Construction of HSC at Raykera Block Bharno in District Gumla
Sl. No. Item Description
1Earthwork
2Earthwork in excavation in foundation trenches in ordinary soil(vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m includingall lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.
3Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
4Earth filling infoundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earthobtainedfrom excavation offoundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I.(mode of measurement compacted volume)
5Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
6Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
7Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
8Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) Foundation
9Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : Column
10Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plainwindow sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Lintel
11providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
12Providing Toe steel reinforcement of 10 mm dia rods as approved design and drawing -do- do- 15%
13Providing Toe steel reinforcement of 12 mm to 20 Dia rods as approved design and drawing -do- do- 65%
14Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
15Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
16Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
17Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
18Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
19Providing designation 75B brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
20Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
21Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.
22Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
23Supplying, fitting & fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
24Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : Kiln seasoned and chemically treated hollock wood,50x20 mm
25Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete
26Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
27Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
29Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B, Fixing with carbon steel galvanised dash fastenerof required dia and size (to be paid for separately)
30Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flat/ Square as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
31Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I.
32Supplying fitting and fixing glass panes including supplying putty. Beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/I. 5.5 mm plain
33Providing and laying Doublecharge vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorptionless than 0.08% and conforming to IS: 15622 / ISO 13006 of approvedmake, in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm .
34Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red, Area of slab over 0.50 sqm.
35Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge
36Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
37Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
38Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
39Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
40Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. 450X450 mm size
41Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
42Providing single layer Naria- tiles in roof including cost of all labour and materials, taxes, all coplete as per building specification and direction of E/I.
43Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10 mm and down gauge), includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as perstandard design :
44Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
45Water proofing for Old and Now Roof Slab • Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied wth brush, roller or spray for water proofing coating as Per ....Mier specificatIons with following steps (a)surface preparation -Providing and cleaning o1 concrete ...lece le remove dust, oil, grease including removal of existing loose paint r coating, and cement laitance by cleaning with comer..ed air 8 water let including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checkedtrodentify seepage eakage On identification of seeps cem t be done with non shrink expanding admixt e a Ind, t 1MYK c g / Dr Fout/Fosroc or equive teems such as those betwe be chamfered with 15 1 41 admixed with ac Fixit or equivalent slum, of acrylic concretein baserovtartg and repaving of all c arapet wall and the roof slab et 50 mm fillet of mortar (Cement sand mer of Sika/ Fosroc/MYK SchomberglDr chamfering a prime coat shall be given with the Repairing surface irregularities, damaged ad cracks if any, with an acrylic polymer modified repair moile, including a coat of bonding agent of the same with cement slurry inctC01; all material, labour, tools complete (b)1st Coat - APOrlit coat of two component acrylic modified, ready to use. flexible come s material on surface saturated dry roof and inside wall of Par ll upto 600 mm by brush or roller After 1st coat re. pgplaisesd c@lot,h5t: kla9y,sw,nheincothaet rost, itahyee r of application , 45 still green 1st coat purpose of measure he entire treated surface will be measured \"4, (c) 2nd Coat -To apply g02 coat of two component acrylic rnorAdmir* ready to use, flexible come\" tonal right angle to the 140,af,•:,-- over the glass fibre laid surface*d alepld be * applied VW Sgmt/coat For the purpose of rnikeSCiretfleritthe entireteaterfstiface will be measured \" After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and found necessary rectification to be done as per satisfaction of E/C The waterproof coating to be protected from damage before screed over it Water proofing Brand - Sika Topseal 109hi / Fosroc Brushbond RI\". Dr Feet Picliflin 2K 1 MYK Actuate\" TG Product Performance Chemical Base F\". A Acrylic copolymer, Part B: Specially graded cementitious powder -D011,4 1.6 fief, (mixed density) at 427°C Tensile Strength -2 N/mm2 atter 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength -2 N/mm2 (concrete failure) (According to ISO4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5 15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) Protection of treated surface with PCC •- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1.1.5 3) with proper slope ( 1 120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items) All corners shall be chamfered with 150mm X 150 mm fillet The rainwater outlets shall be just leveled with the screed concre toe ure smooth discharge of water - the peripheral gaps be en p pi o and concrete surface should be packed pro with n c e and tiurpheral mouth to be sealed with ure Pvt Ltd. / MYK Schomb Fixit/Fosroc For the purpose of measurement the ed surface will be measured \"ensitive epoxy putty o (e)Groove of PC should be filled with Polysulphide Sealant. (Paid Separate* d - Sika India Pvt Ltd / MYK Schomberg / Dr FixitiFosroc W for five years
46Covering of treated surface with PCC .- Providing 25 mm thick Cement Alf, Concrete M20 1:1. :3) maintaining slope in alternate 2 mt x 2 mt panels with aaprove. of stone chips of 20 mm to 6 mm size graded and cleaned sand 2.5 to 3 including screening,shuttering,and mixing cement concret . fixer with admixture of integral water proofing and placing in posi . ing curing,taxes and royality all complete as per building specifi nd direction of Ell. Panels that has been left shoul be casted next dysThere should be 6 mm gap between Panels .Brand Sika _Plastocrate Aus,MYK proof WP10, Fosroc- Conplast X421 lc& Dr Fixit Pidiproof LW+
47Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as Per drawings and technical specifications and direction of E in Charge (with 18% GST Polysulphicle Fosroc-Thoflex 600.Dr Fixit Pidiseal PS(42P) !MraYndK -Seikaal PS or Euivalent
48Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
49Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
50Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
52Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
53Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
54Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
55Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)
56Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
57Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
58For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately).Powder coated aluminium (minimum thickness of powder coating 50 micron)
59Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
60Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
61Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I Bricks (7+1Km)
62Sand(10+1Km)
63Stone Chips (22 Km)
64Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.(a) From 0.00 M to 50.00 M below
65(b) From 51.0 M to 125.00 M G.L.
66Supplying, assembling, lowering and fixing in vertical position in borewell,unplasticizedPVCmediumwellcasing(CM)pipeof required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
67Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \"V\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
68Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
69Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
70Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
71Supplying Full automatic star selta starter to operate induction motor working on 415v 3phase50hz with no coil. Over load element , On _OFF pushbuttom with necessary materials and connection to Supply etc complete starter with original sheel steel encloser as per 3914.F.A.S.D starter upto 5 H.P
72Supplying Filling and Fixing 3 Core 4 sqmm flat caopper submersible cable finolex / Hevels make including all taxes , royalty etc. All complete job as per direction of E/I
73Supplying Filling and FixingGI Pipes ( Tata Mark or Equivalent ) as per IS -1239 ( Part -01) 2004 ISI Marked / Medium Quality 40 mm diaAll complete job as per direction of E/I
74SEPTIC TANK :- Earthwork in excavation in foundation trenches in ordinary soil(vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 m includingall lifts, levelling , ramming the foundation trenches, removing roots of trees, serbs all complete as per approved design,building specification & direction of E/I.
75Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
76Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
77Providing designation 75A brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
78Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
79Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : Column
80Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plainwindow sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). Lintel
81Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
82providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
83Providing Toe steel reinforcement of 12 mm to 20 Dia rods as approved design and drawing -do- do- 65%
84Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
85Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
86Providing 1.5mm cement punning including curing, carraige of water with all leads and lifts as per building specification and direction of E/I.
87Carriage of materials from source to site work including loading & unloading all complete job as per specification and direction of E/I Bricks (7+1Km)
88Sand(10+1Km)
89Stone Chips (22 Km)
90Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of Parry Hindustan or any other I.S.S. approved make with 100 mm H.C.I., \"p\" trap 15 litres C.I.. or C. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32 mm alkathene/P.V.C. telescopic flush, pipe about 2 M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware where footrest to be fixed in floor 15 mm C.I. body brass spindle stop cock of weight not less than 50 grms. 15 mm P.V.C. connection pipe 450 mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l.580mm. long - with 10 litre low level PVC cistern
91Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with \"p\" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With \"P\" trap (b)10 lit. low level P.V.C. cistern
92Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
93Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I. C.P. brass towel rail 20mm x600mm with bracket container
94Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of270 mm, effective length of tail pipe 260 mm from thecentre of the waste coupling, 77 mm breadth with 25 mmminimum water seal, weighing not less than 260 gms
95Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved qualityand colour, weighing not less than 105 gms.
96Providing and fixing c.p. towel ring complite with brackets fixed to wooden cleats with c.p.brass screws with concealed fitting arangement of approved qualite colour and make.(Mark or equipment)
97Providing and fixing C.P. brass bib cock of approved conforming to IS 8931 : 15 mm nominal bore
98Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
99Providing and fixing toilet paper holder :C.P. brass
100Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. 75 mm diameter
101Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.110 mm diameter
102Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm Coupler
103110 mm Single tee with door
104110 mm Bend 87.5°
105110 mm Shoe (Plain)
106Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 75 mm
107110 mm
108Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.
10925 mm nominal dia Pipes
11032 mm nominal dia Pipes
11140 mm nominal dia Pipes
11250 mm dia
113Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wallsetc.15 mm nominal dia Pipes
11420 mm dia
11525 mm dia
11632 mm dia
117Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design
118Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
119Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GIbox etc as required.Group C
120Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cablefor loop earthing as required.
121Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cablefor loop earthing as required.
122Wiring for circuit / submain wiring alongwith earth wire with the following sizesofFRPVCinsulatedcopperconductor,singlecorecablein surface/ recessed PVC conduit as required.2x1.5sq mm + 1x1.5 sq mm earth wire
123Wiring for circuit / submain wiring alongwith earth wire with the following sizesofFRPVCinsulatedcopperconductor,singlecorecableinsurface/ recessed PVC conduit as required.2x1.5sq mm + 1x1.5 sq mm earth wire
124Wiring for circuit / submain wiring alongwith earth wire with the following sizesofFRPVCinsulatedcopperconductor,singlecorecableinsurface/ recessed PVC conduit as required.4x2.5sq mm + 2x2.5 sq mm earth wire
125Wiring for circuit / submain wiring alongwith earth wire with the following sizesofFRPVCinsulatedcopperconductor,singlecorecableinsurface/ recessed PVC conduit as required.4x10 sq mm + 2x6 sq mm earth wire.
126Supplyinganddrawingco-axialTVcableRG-6grade,0.7mmsolid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required.
127Supplying andfixing offollowing sizes ofPVCconduit alongwith the accessoriesinsurface/recessincludingcuttingthewallandmaking good the same in case of recessed conduit as required.20mm dia
128Supplying andfixing offollowing sizes ofPVCconduit alongwith the accessoriesinsurface/recessincludingcuttingthewallandmaking good the same in case of recessed conduit as required.25mm dia
129Supplyingandfixingfollowingmodularswitch/socketontheexisting modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps one way switch
13015/16 amp one way switch
1315/6 amp 3 pin socket outlet
1325/16 amp 6 pin socket outlet
133TV anteena Socket Outlet
134Supplyingandfixingsteppedtypeelectronicfanregulatoronthe existing modular plate switch box including connections but excludingmodular plate etc. as required.
135Supplyingandfixingmodularblankingplateontheexistingmodularplate & switch box excluding modular plate as required.
136Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (78mm x 78mm x 45mm) - For Telephone & TV outlet.
137Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4/5 Module (78mm x140mm x 50mm)
138Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (78mmX205mmx50mm)
139Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.
140Supplyingandfixingbrassbatten/angleholderincludingconnection etc. as required.
141Supplying and fixing Dingdong sound call bell single phase, 230 volts,complete as required.
142Installation,testingandcommissioningofceilingfan,includingwiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required.
143Installation of exhaust fan up 450 mm sweep in the existingopeningincludingmakingtheholetosuitthesizeofabovethefan, making good the damage, connection, testing, commissioning etc. as
144Supplyingandfixing20amps,240volts,SPNindustrialtype,socket outlet,with2poleandearth,metalenclosedplugtopalongwith20 amps“C” curve,SP, MCB,in sheetsteelenclosure,onsurfaceor in recess,withchainedmetalcoverforthesocketoutletandcomplete with connections, testing and commissioning etc. as required.
145Supplyingandfixingfollowingways,horizontaltypethreepoleand neutral,sheetsteel,MCBdistributionboard,415volts,on surface/recess, completewith tinnedcopper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).8 Way (4+24), Double Door Horizontal Type
146Supplyingandfixing6Ampto32Amprating240volts,10KA \"C\" Curve Miniature Circuit Breaker suitable for inductive loads of followingpolesintheexistingMCBDBcompletewithconnections, testing and commissioning etc.,as required.6 / 32 Amp Single Pole
14740 Amp TPN
148Supplying and fixingSingle pole blanking plate in the existing MCB DBcomplete etc. as required.
149Supplyingandfixingoffollowingratingdoublepole(Singlepole& neutral),240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.40 Amps
150Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke andsalt) as required.
151Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess forconnections etc. as required
152Providingandfixing6SWGdiaG.I.wireonsurfaceorinrecessforloopearthingalongwithexistingsurface/recessedconduit/submain wiring/ cable as required.
153Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto andincluding 1100 volts. (conforming toIS-7098. (Part-I).4 core,16 sq.mm.
154Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existingsurface/ recessed Steel/ PVC conduit as required.1 run of cable
155Laying of one number PVC insulated and PVC sheathed / XLPE power cableof1.1KVgradeoffollowingsizedirectingroundincluding excavation, sand cushioning, protective covering and refilling the trenchetc as required.Upto 35 sq. Mm
156Supplyingandmakingendterminationwithbrasscompressiongland andaluminiumlugsforfollowingsizeofPVCinsulatedandPVC sheathed/XLPEaluminiumconductorcableof1.1KVgradeasrequired.4 X 16 sq. mm (28mm)
157SITC of following rating recess / surface mounted LED round / square shapedownlightluminariewithpressurediecasthousingforsingle phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required. Make:- Havells/Philips/Crompton/Wipro.18 /20 W LED Round Down Light (Surface)
158Buik Head Fitting With 9/10 Watt LED
159S.I.T.C offollowing ratingsurface mountedLEDTubeLighting Fitting Suitablefor230V50Hz,SinglePhaseSupplyetc.completeas10/12W LED Tube light
160S.I.T.C offollowing ratingsurface mountedLEDTubeLighting Fitting Suitablefor230V50Hz,SinglePhaseSupplyetc.completeas20/22 W LED Tube Light
161SITCof 300mm(12\")Exhaustfan(Metalbody)suitableforsingle phase230volts,50Hz.,ACsupplycompletewithmotor, louvers/shutters etc. complete as required.Make :-Usha/Crompton / Havells .
162Supply, Installation, Testing and Commissioning of following size fan 3 BladesconfirmingtoIS:374:2019includingwiringthedownrodsof strandedfor230V50Hz,singlephasesupplyetc.completeas required.1200 mm ( 48\") Ceiling Fan
163Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properlydesigned foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing 80 mm x 60 mm rectangular )
164G.S.T. @ 18%
165Labour cess @ 1%

AI Tender Summary

OUR REF NO 42294513
AUTHORITY Local Bodies
TENDER VALUE 55.50 Lakhs
LAST DATE 22-02-2024
Authority
Authority Name Zilla Parishad
Work Description Construction Of Hsc At Raykera Block Bharno District Gumla
Basic Detail
Tender No DOPR/DE/Gumla/02/2023-24
Bidding Type Tender
Location
City bharno
State Jharkhand
Key Dates
Publish Date 16 Feb 2024
Submission Date 22 Feb 2024
Open Date 23 Feb 2024
Finance
Tender Value 55.50 Lakhs
Tender Fee 10000
EMD 1.11 Lakhs
Exemption Not Available
Document List
d8df2cc9-488b-44e5-9875-a02aeefbb8da.html
BOQ_111527.xls
SBD06.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 16, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 22, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 23, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

d8df2cc9-488b-44e5-9875-a02aeefbb8da.html

xls

BOQ_111527.xls

pdf

SBD06.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender