| 1 | CIVIL WORKS:Earthwork in excavation of foundation in hard soil including dressing & levelling of bed within initial lead of 50mt. & lift of 1.5mtr etc complete as per the direction of the Engineer-in-charge. |
| 2 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-in-charge. |
| 3 | Cement concrete (1:4:8) with 4cm size h.g.c.b. metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all material to worksite, supply of cement T&P required etc. complete as per the direction of the Engineer-in-charge. |
| 4 | Fly Ash Brick masonry 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-in-charge. |
| 5 | R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-in-charge. |
| 6 | C.B. Brick masonry 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in Super structure etc. complete as per the Engineer-in-charge. |
| 7 | Rigid smooth centering & shuttering for R.C.C. works including false work & dismateling then after including cost of materials in ground floor complete as directed by the Engineer-in-charge. |
| 8 | M.S. reinforcement for R.C.C. work including supplying, straightening, cutting, bending, binding & tying the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Still Bar (FE 415/ FE 500) |
| 9 | 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-in-charge. |
| 10 | Cost of laying & fittings ofTees and other fittings along the pipeline as per direction of Engineer-in-charge. |
| 11 | Cost of Iron Door of (size 1.2m x 1.98m), Costof 2 nos. of Iron Ventilator of (size 0.45m x 0.30m) and fitting including all costs and taxes etc. as per direction of Engineer-in charge. |
| 12 | 40mm thick grading concrete (1:2:4) with 12mm size hard granite chips for RCC work on roof slab including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-in-charge. |
| 13 | Cost of Iron Door of (size 1.2m x 1.98m), Costof 2 nos. of Iron Ventilator of (size 1.00m x 1.20m) and fitting including all costs and taxes etc. as per direction of Engineer-in charge. |
| 14 | Dry Brick Khoa of 10cm thick well watered & rammed to receive A.S.Flooring complete including all cost of all labour, materials , transportation, taxes etc. complete. |
| 15 | 2.5cm A.S.Flooring in CC (1:2:4) including punning with 12mm HG Chips |
| 16 | Priming of M.S.Door with approved primer |
| 17 | Painting of 2 coats with approved shade of paint including cost, labour etc complete |
| 18 | White washing 2 coats with shell lime over 2 coat white washing. |
| 19 | Colour washing 2 coats with shell lime over 2 coat white washing. |
| 20 | Filling the foundation and plinth with excavated material as directed by the Engineer-in-charge. |
| 21 | Labour charges for letter writting on display board in black colour on yellow back ground painting including cost of material, labour etc. |
| 22 | 7.5 HP Submersible motor pump of 25 mtr head with 900 LPM discharge of reputed brand with BEE Star rated energy efficiency suitable for 200 mm dia tube well as per IS specification with 2 pair U-Clamp & 30 mtr of 4.00 sqmm flat cable andImpeller: Bronze grade LTB-2 of IS 318/1981 as per IS specification |
| 23 | Cost of 63 Amp. Triple pole Main Switch& natural of voltage range 440 volt of re-wirable fuse and shall confirming to IS-4064(PT-I & II ) with ISI marking of reputed company with utilisation capacity category AC-22including all taxes etc. |
| 24 | Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 8.9 to 13.5 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt Meter, Ameter, MCB in complete shape including Indicator Lamp. |
| 25 | 4KVAR Power ShuntCapacitor with ISI mark of reputed company. |
| 26 | 3x10 sqmm PVC insulated (HD) tropoder armoured Electric Cable with alluminum conductor for use in 3 phase power system of working voltage upto & including 1100 volts at 50Hz confirming to IS 7098(Pt-II) including cost of transportation to site and laying below 0.9mtr of the ground and filling the excavated materials including watering and rammin including all taxed etc. |
| 27 | 2.50mm2 Submerssible (3 Core) Flat Cable ISI mark of reputed company. |
| 28 | Cost of Electrical earthing including cost of 30mm dia.X3m. long G.I. earthing pipe with proper sloting(TATA make), 30mm dia G.I.Flange for earth pipe, No. 6 G.I. wire, 100 amp cable socket, Al-ka-pea, 50mm dia flexible conduit pipe, 50mm long TVS nut & bolt including petty materials like charcoal, common salt etc. complete, transportation of all earthing materials & tools including loading and unloading, storing & shifting to project site complete and cost of labour for earth works involved including taxes and other charges if any all complete. |
| 29 | Electrical installation and energisation (including cost of volt meter-5 nos, CT type Amp. Meter-5 nos, selector switch- 5 nos, CT - 2 nos(100:5), indicator - 15 nos,100 Amp Kit kat - 15 nos, cable socket, internal and external wiring at pump chamber etc. |
| 30 | T&P materials kit comprising of Electric currentTester, Screw Driver,DE Spanner, Plier and Ring Spanner all suitable for maintainance of LIP etc. complete. |
| 31 | 100mm dia nominal bore G.I.pipe having wall thickness 4.5mm electrical resistance welded of medium class confirming to IS- 1239(part-1/2004) with latest ammendments, screwed at both ends as per IS-554 with socketed at one end and the other end protected with plastic threaded protector including its transportation and unloading at L.I.P. site. The socket confirming to ISI 1239(part II/1992) with latest ammendments in random length of 4 to 7 mtr. Each pipe should bear IS certification and manufacturers name/trade mark. |
| 32 | 100mm dia G.I.Socket( Medium Duty) with ISI mark of reputed company. |
| 33 | 200X100mm dia M.S. T/W cap withISI mark of reputed company. |
| 34 | M.ST/W Clamp (Pair) 100mm dia with ISI mark of reputed company. |
| 35 | 12mm dia PVC Insulated Steel Wire Rope ISI mark of reputed Company. |
| 36 | Fabrication of special joint including cutting, welding of pipes one end with other end suitable for connection to delivery pipe line of pump set including cost of cutting , welding and utilisation of welding materials and tool & plants, fiiting the pipes in proper allignment with delivery pipe line etc. complete as per direction of the Engineer-in-charge. |
| 37 | 100mm dia G.I.Bend( Medium Duty) conforming to IS No-1239 (part II/1992) with ISI mark of reputed company. |
| 38 | 100mm dia G.I.Flange( Medium Duty) conforming to IS No-6392/1971 with ISI mark of reputed company. |
| 39 | 100mm dia C.I.Double Flanged Non Return Valve swing type PN-1.0 (IS-5312(Part-I-2004) with bypass arrangement with ISI mark of reputed company. |
| 40 | Supply of NutBolt & Rubber insertion including all costs and taxesetc. complete except GST. |
| 41 | Labour charges for Installation of pumpset and delivery pipes and fittings including fitting of Sluice Valve, NR Valve, Air Release Valve, Riser Tee, lowering of pump and transportation etc complete as per the direction of the Engineer-in-charge. |
| 42 | 50mm dia C.I.Air Release Valve (single action) with saddle and Raiser pipe conforming to IS 14845 (SI) with ISI mark from reputed company. |
| 43 | 160mm x 100mmM.S. Reducer |
| 44 | Supply of 160mm dia unplasticised riged UPVCpipe ivory in colour having specific gravity of 1.40 to1.46 gms/cc of straight length of 6(six) meter for portable water supplies conforming to IS-4985/2000 of BIS-Amendment-2 read with Table-1 of IS-specification bearingISImarks for working pressure CI-I UPVC pipe to withstand pressure of 2.5kgf/sqcm& the specification and manufacture name should be prominently marked on body of each pipe as per the latest Amendment of IS-4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transporation to work site in complete shape and handed over to Pani Panchayat President or Secretary. |
| 45 | Fitting of un-plasticised 160mm diaPVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non-head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from village to worksite and testing of pipe line etc. complete as per the direction of the Engineer-in-charge. |
| 46 | 160×160×160mm F P.V.C Equal Tee(W.P 4Kg/Cm2) conforming to IS-4995/ 1988 with latest amendment. |
| 47 | 160mmx160mmx110mm dia Weldless G.I.Tee (3.6mm thickness) with bend, closing and opening arrangement of reputed company. |
| 48 | 150mm diaC.I. Butter Fly Valve BS:5155/15: 13095-CI MOC Lever Operated PN-1.0 with ISI mark of reputed company. |
| 49 | 160 mm F P.V.C End Cap (W.P-10 Kg/cm2) conforming to IS-4995/ 1988 with latest amendment. |
| 50 | 160 mm F P.V.CCoupler (W.P 4Kg/Cm2) agricultural PVC fittings conforming to IS-4995/ 1988 with latest amendment. |
| 51 | Solvent cement of approved quality for jointing of PVC Pipes with all cost and taxes etc |
| 52 | Miscellaneous item like cleaning of site, overburden earth cutting etc. |
| 53 | ELECTRIFICATION:Construction of 3 phase 11 KV HT line as per REC standard confirming to IE Rules 1956 with 300 kg 9 M long PSC Pole with 55 Sqmm AAA Conductoraverage span 40mtr ,11 KV \"V\" Cross arm required No.of 11 KV T & C Disc. polymer Insulators in tension point &11 KV Pin Polymer insulators, Couping & Padding of Poles with all G.I.Channels. Danger Board at each Pole, Anti Climbing Devices, Stay Set at Bending point & double stay at end point with 18 mm G.I.H.T.Stay, concreting of Stay with Anchor plate, guarding at Road crossings etc if required. including cost of all materials, labour, transportation,inspection & commissioning etc. complete. |
| 54 | Construction anderection of 11 /0.4 KV ,25 KVA Double Pole mounted Substation with5mtrx3mtrx1.5mtr height mesonary toe wall /G.I. Flat fencing boundary wall withFlat with Polymer insulator ,L.T DistBox with MCCB , Aluminim bus bar of single bay with kitkat fuse , sand filling and metal spearding with M.S.Grill gate ,all Channel matrials should be G.I , 7 Nos earthing with chamber with 3mtr G.I pipe of40mm dia with connecting of 25mmx 5mm G.I flat to all earthing including 25KVA BIS Leble-II Star rated Transformer confirming to RE Rules 1956, mounted on 2.44 Mtr. Long structure, supported in 300 kg 9 mtr long PSC pole,transformer hard channel & top channel made of 2.8 M long 100 X 50 X 6 mm G.I.Channel, Transformer belting on 2.80 M long 50mm X 50mm X 5 mm G.I.Angle, (all REC SPN Std.F-3) with all accessories like 3 pole 11 KV HG Fuse(F-5)& A.B.Switches(F-9) both mounted on 2.8 M long 75mm X 40mm X 6 mm G.I.Channel and supported by 1.0 M long 50 X 50 X 5 mm G.I.Angle, with 3 No. 11 KV Lightening Arrestors and Danger board at each Pole, Anti climbing Devices & all other necessary fittings i.e required size Nuts & Bolts, Brackets, Cable, Cable Sockets as per TPCOCL specification etc. including cost of all materials, labour , transportation complete with liasioning for testing inspection & commissioning as per specification of TPCODL etc complete. |
| 55 | DRILLING OF TUBE WELL:Labour for drilling of perfect vertical bore hole of specified depth below ground level in alluvial soil strata by mud rotary rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including supply of Rig with it’s accessories, tools and plant and consumables etc. for lowering of finished bore for 400mm dia & suitable for lowering of 200mm diaPVC pipes for housing, fitted with socket with or without well screen as per the necessity for the soft, medium, hard and boulder formation (G.I./PVC casing pipes if required by the contractor to prevent collapse of over bourden portion ) including lower and withdrawing of casing pipe after drilling 200mm to 400mm dia in over bourden portion up to 100 Mtr. For 0 mtr. to 63 Mtr |
| 56 | Supply of all labour and T & P for lowering following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position including cutting and threading pipe and slotted pipe and fixing all joint materials, tools and plantsetc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry to foreign materials from above excluding cost of fittings and jointing materials and packing gravels around the casing in the annular space as per the direction of the Engineer0 Mtr to 60 Mtr |
| 57 | Providing of 200 mm dia PVCwell casing as perASTM-D-1785/2004 ( Schedule -80) blue in colour having specific gravity of thematerials of the pipe 1.40 to1.46 gms/cc straight length of 3 mtrs PVC Pipes includingentire cost involved inPre-delivery test & Post delivery test with correspoding test marking on the body of pipes along with name & address of manufacturer, cost of transportation from factory to project site with loading and unloading,storage at site, watch and ward etc. till completion of project work and handing over to Panipanchayat all complete with due approval of authority as per direction of Engineer-in-charge. |
| 58 | Cost of slotting charges of 200mm dia PVC(ASTM-D)Sch.-80 pipe |
| 59 | Cost of bentonite drilling mudincluding transportation to site,etc. |
| 60 | Providing of Graded and washed gravel of ‘B’ grade including transportation to site etc. complete as per direction of Engineer-in-charge. |
| 61 | Cost of 200mm dia PVC Cone |
| 62 | Cost of 200mm dia PVC end cap |
| 63 | Cost of 200mm dia PVC Nipple |
| 64 | Cleaning and developing the production well using own Air compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of the Engineer-in-Charge. |
| 65 | Excavation of mud pit, settling pit & fluid channel& back filling with preparation of approches to movement of rig & ancillaries etc.Complete. |
| 66 | Operation of 5HP water pump for filling of mud pit |