Tender For Street Light And Building Electrical Maintenance Of Jabalpur Divisional Office Building ., jabalpur-Madhya Pradesh

Board Of Secondary Education-CBSE has published Tender For Street Light And Building Electrical Maintenance Of Jabalpur Divisional Office Building .. Submission Date for this Tender is 28-02-2024. Electrical Maintenance Tenders in jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

42277862
Tender For Street Light And Building Electrical Maintenance Of Jabalpur Divisional Office Building .
Open Tender
Indian
Madhya Pradesh
jabalpur
28-02-2024

Tender Details

Tender For Street Light and Building Electrical Maintenance Of Jabalpur Divisional Office Building .

Key Value

Document Fees
INR 2000 /-
EMD
INR 27927.0 /-
Tender Value
INR 13.96 Lakhs /-

BOQ Items

Name of Work:Street Lightand Building Electrical Maintenance of JabalpurDivisional officebuilding .
Sl. No. Item Description
1Painting of poles
2Removing of old paint from steel and other metallic surface and making surface even.
3Prima coat over new steel and other metallic surface with red oxide zinc chromide paint complete with supply of material labour etc. including preparation of surface.
4Prima coat with aluminium paint, brushing complete with material and labour including preparation of surface
5Split AC (non inverter) :- Supply installation testing and commissioning of split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable of providing cooling between +/-5deg.C to 50 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condense water outlet pipe 2 mtr. complete etc as required. Outdoor/indoor units should be of same make (brand).
61.8/2 TR star rating 3 star
7Supply, installation, testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing, nitrile rubber insulation 6/9mm thick class "O", etc complete as required.
8Copper tube 1/4"
9Copper tube 3/8"
10Copper tube 1/2"
11Copper tube 5/8"
12Supply, fixing & testing of approved make globe type polycarbonate post top lantern, consisting of cast aluminium spigot complete with all accessories, lamp holder, (without lamp) including fixing on gate pillars/exiting G.I. pipe, pole with connection & all required materials on existing required size of G.I. pipe, suitable for CFL/LED lamp for mentioned below sizes :-
13300 mm (12")
14Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job.
1590Watt, color temp 3000-6500k as required.
16Supply, fixing & testing of approved make of LED integral type bollard cylindrical/square shape housing cast aluminium dome shape top cover fixed with cylindrical shape acrylic cover having base plate with holes for direct mounting complete with all accessories including preparation of foundation, fixing, connection etc. as required. LED of 1 to 3 Watt each assembled on single MCPCB, system lumens output with efficacy>90 lm/W. luminaire having color temp upto 6500K & 50000 burning hrs. life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare, comprises of driver PF> 0.95 & surge protection 10KV. IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
17Bollard LED 8-10 Watt cylindrical shape height > 700mm, color temp 3000-6000k
18Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
19150Watt, color temp 3000-6500k as required.
20Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor
2125 sq. mm, 3½ core armoured
2210 sq. mm, 4 core armoured
23Laying of one number armoured / unarmoured power cable 1:1 KV grade of size not exceeding 25 sq. mm in the existing RCC hume/stone ware/G.I. pipe/surface in existing trench as required.
24Laying of one number armoured / unarmoured power cable 1.1KV grade of size not exceeding 25 sq. mm direct in ground including excavation in all soil/ murrum /soft rock, sand cushioning, protective covering and refilling the pit etc. as required.
25Laying of one number armoured/unarmoured cable 1.1KV grade of size not exceeding 25 sq. mm on wall/truss with approved type of iron clamp etc. as required.
26Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make.
274.0 sq.mm multi strand
28Supplying & installing G.I. pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete.
2950.00mm, For "B" class pipe ISI marked (IS-1161- 68), For "B" class pipe ISI marked (IS-1161- 68)
30Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.
313 X 2.5 sq. mm.
32Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of "C" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10 kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002 & 60947-2 but without enclosures :-
33MCB SP 6Amp to 32Amp 10kA rating, Single pole
34MCB TP 50Amp to 63Amp 10kA rating, For Triple pole
35MCB FP 50Amp to 63 Amp 10kA rating, Four pole
36Supplying of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, (Ics=100%Icu) AC supply with thermal - magnetic release having respective breaking capacity (KA) at 415 Volts cited against their range standard conforming to IS/IEC 60947-2
37MCCB 25kA current rating - 125Amp & adjustable overload setting 80% -100% of In, adjustable short circuit setting 6-10 In 3 Pole
38Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only)
39MCB/Isolator SP/DP
40MCB/MCCB Isolator TP/TPN/FP
41Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification
42Digital Ampere Metre with CTs with selector switch
43Digital Volt Metre with selector switch & HRC fuse
44LED lamp indicator
45Supplying and fixing of cooler/A.C. M.S. angle iron stand including flat iron supports, grouting in wall if required, welding, painting with primer and two coat of superior quality paint complete.
46Supplying and fixing PVC conduit ISI marked FRLS along with accessories on surface etc. as required
47PVC conduit 20 mm. (MMS)
48PVC conduit 25 mm. (MMS)
49Supplying and fixing PVC casing and capping (double fold) ISI marked along with accessories on surface etc. as required
50mPVC casing and capping (double fold) 25 mm x 12mm
51mPVC casing and capping (double fold) 32 mm x 12mm
52Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC FRLS insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for :-(Using modular accessories)
53Primary short point, Light point/fan points
54Primary medium point, Light point/fan points
55Primary long point, Light point/fan points
56Short point, 3 Pin 6 Amp socket outlet on separate board
57Medium point, 3 Pin 6 Amp socket outlet on separate board
58Long point, 3 Pin 6 Amp socket outlet on separate board
59Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. Socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit with required materials as per specification on same board.
60Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) of ISI marked suitable size etc. as required as per specification
612x2.5 Sq.mm
624x2.5 Sq.mm.
636x2.5 Sq.mm.
648x2.5 Sq.mm.
65Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. conduit (MMS) ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside conduit, screwless connector for joints as per specification for :-(Using modular accessories)
66Short point, On separate board
67Medium point, On separate board
68Long point, On separate board
69Extra long -I, On separate board
70Extra long -II, On separate board
71Extra long -III, On separate board
72Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp
73Supplying and fixing of approved make modular type G.I. metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earth terminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-
741Or 2 Module metal box
753 Module metal box
764 Module metal box
776 Module metal box
788/9 Module metal box
7912 Module metal box
8016 Module metal box
8118 Module metal box
82Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification.
833 X 1.5 sq. mm.
843 X 2.5 sq. mm.
853 X 4.00 sq. mm.
86Wiring for sub-mains with PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid PVC conduit (MMS) FRLS ISI marked of suitable size (conduit included) including 2mm thick accessories, connection etc, as required as per specification. (Refer General Notes for Classification of Conduit Wiring Point No.11)
876.0 sq. mm. cable, 3 Wire sub main
88Supply of ISI marked and approved make of moulded case circuit breaker (MCCB) suitable for 3 phase,3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828
89MCCB 25kA current rating, 3P -25 to 100Amp & 80% - 100% adjustable
90Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)-
9112 Way double door IP 43 protection
92Supplying of approved make TPN MCB DB metal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator):
934 Way (8+12)
94Labour charges for fixing sheet steel enclosures, MCB/MCCBDB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete :-
9527.11.1 to 27.11.7 ; 27.12.1 to 27.12.3 & 27.13.1
96Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing boar
97100 Watt(2 module)
98Supplying and fixing of analog time switch for automatic ON - OFF street light of approved make in existing LT panel including connections etc. as required as per specification
99Supply and fixing Led tube rod comprising of LED tube with nonintegral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
100Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser.
101Supply and fixing of recessed mounting type Led light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF> 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
102LED luminiare 2" X 2", 36Watt, color temp 3000-6500k as required.
103Supply and fixing of surface mounting type LED light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver, PF> 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job.
104LED luminiare 2" X 2", 36Watt, color temp 3000-6500k as required.
105Supply and fixing of recessed mounting LED swivel type COB downlighter, having color temp upto 6500K & having 20000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy>80lm/W. LED driver PF > 0.9, THD < 20% & surge protection 5KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium / CRCA powder coated frame with glare free diffused polycorbonate cover. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete the job. Guarantee as per tender agreement condition.
10612/15W
107Supply and fixing recessed mounting LED down lighter, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver PF > 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of pressure die cast aluminium/CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job..
10814/15 Watt, color temp 3000-6500k as required.
109Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments
110Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value = 4.00 as per BEE..
111Supplying, erection and testing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and including raw bolt/anchor hole fastener etc. complete finished and as required.
112400 mm sweep
113Supplying and fixing of deluxe fresh air fan with louvers (ventilating fan) with self-closing louvers of decorative PVC blades mounting square frame of approved make complete with all necessary material as required
114300mm RPM1300/1400
115Supplying, erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as required
116300mm sweep RPM 900 / 1400
117Supply of ISI Marked Switch Disconnector Fuse (SDF), open execution (Panel mounting cubicle type) confirming to IS:13947 (part I & III ) 2 pole , AC -23A ,50 Hz , 415 Volt with 2 HBC fuses complete
11832 Amps
119Supply of ISI Marked Switch Disconnector Fuse (SDF), open execution (Panel mounting cubicle type) confirming to IS:13947 (part I & III ) 3 pole and neutral , AC -23A ,50 Hz , 415 Volt with 3 HBC fuses complete.
12032 Amps
121Supply of ISI Marked Automatic Star-Delta Starters confirming to IS : 13947-4 with suitable over load relay range and contactor size & timer 415 V , 3 -Phase with two earthing terminals
1223 to 12.5 HP
123Supplying and drawing following pair, 0.5 mm PVC insulated copper conductor unarmoured telephone cable in existing surface/concealed, steel/PVC conduit as required.
124Telephone wire 0.5 mm, 1 Pair
125Telephone wire 0.5 mm, 2 Pair
126Supply, installation testing and commissioning RJ - 45 computer jack cat 6 with shutter modular (1Module)
127RJ - 45 computer socket cat 6 tool less connection (1Module)
128Supplying and drawing 4 pair un-shielded twisted pair (UTP), 0.5 mm PVC insulated copper conductor un-armoured Cat-6 computer cable FRLS in existing surface/concealed, steel/PVC. conduit/ casing-n-capping as required.
129Supply and fixing as per specification polycarbonate batten holder/angle holder of approved make with necessary materials complete
130Supply and fixing as per specification call bell/buzzer of approved make with necessary materials complete.
131Ding dong bell
132Supply and fixing of multi core round FRLSH PVC insulated copper (flexible) conductor & PVC sheathed cables 1100Volts as per IS:694-1990 of approved make
133(50/0.25 mm) Three core 2.5 sq.mm.
134Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete.
1356Amp SP 250 Volt deluxe (piano key type
13616/20Amp SP 250 Volt deluxe (piano key type)
1376/10Amp SP 250 Volt modular switch
13816/20Amp SP 250 Volt modular switch
139Supply and fixing as per specification socket outlet of approved make & ISI marked with necessary material complete
1406Amp 250 Volt 3 Pin flush type
14116Amp 250 Volt 3 Pin flush type
14210Amp 250 Volt 3 Pin modular type
14310/16/20Amp 250 Volt 3 Pin modular type
144Supply and fixing as per specification polycarbonate ceiling rose 3 plate of approved make ISI marked with necessary material complete.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail